Tender For Special Repair To Officers Married Accn Block No P34 04 Quarters At Manekshaw Enclave Under Ge S Ambala Cantt, ambala-Haryana

Military Engineer Services has published Tender For Special Repair To Officers Married Accn Block No P34 04 Quarters At Manekshaw Enclave Under Ge S Ambala Cantt. Submission Date for this Tender is 30-05-2025. Building Work Tenders in ambala Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

49077190
Tender For Special Repair To Officers Married Accn Block No P34 04 Quarters At Manekshaw Enclave Under Ge S Ambala Cantt
Open Tender
Indian
Haryana
Ambala
30-05-2025

Tender Documents

Tender Details

Tender For Special Repair To Officers Married Accn Block No P34 04 Quarters At Manekshaw Enclave Under Ge S Ambala Cant; 1 Material and labour for cutting holes exc 400 Sq. cm but not exc 0.10 sqm into or through brick walls built in cement mortar and making good in cement concrete 1:2:4 type B0 1 as required complete all as specified and directed by Engineer-in-Charge. 2 Material and labour Forming jambs, etc to openings, including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work; new work built in cement mortar 1:6, complete all as specified and directed by Engineer-in-Charge. 3 Demolition of cement concrete (any type) for existing sunken portion of WC/Floor trap incl removing of all debris from site to a distance exc 250 m but not exc 500m and deposited where directed incl cleaning of surface with wire brushes and water , complete all as specified and directed by Engineer-in-Charge. 4 Material and labour in repair for 40mm dia (Bore) GI pipe medium grade as in spout complete all as specified and directed by Engineer-in-Charge. 5 Material and labour for PCC 1:5:10 type E2 using 40mm graded aggregate as in filling in sunken portion floor ,rounded or chamfered on edges complete all as specified and directed by Engineer-in-Charge. 6 Material and labour for sunken floor water proofing treatment complete all as under - (a) scrapping the surface with wire brush and cleaning with water and allow to dry (b) Applying cement slurry @ 3.0 kg/sqm duly mixed with water proofing compound (C) 15 mm thick cement plaster 1:3 with additional floating/setting coat mixed with water proofing compound as per manufacture instruction ( the corner will made rounded in concave shape)(D) Applying cement slurry @ 3.0 kg/sqm duly mixed with water proofing compound (E) apply one coat of hot bitumin grade 85/25 conforming to IS 702 @ 1.2 kg/sqm . (f) supply and laying APP with non woven polyster reinforced sheet 3mm thick weight not less than 3.00 kg/sqm (G) Applying one coat of hot blown bitumin grade 85/25 conforming to IS-702 @1.20 kg/sqm (H) Curing the sunken portion with water min 48 hours by ponding. (Water proofing compound shall measured and paid separately), complete all as specified and directed by Engineer-in-Charge. 7 Demolition of brick work built in CM incl all quions arches, pillar etc complete all as specified and directed by Engineer-in-Charge.. 8 Material and labour for brick work with old size sub class ‘B’ bricks,straight or curved on plan to any radiousbuilt in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge. 9 All as per item No 08.00 above but except bricks. 10 Material and labour for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 etc ,complete all as specified and directed by Engineer-in-Charge. 11 Material and labour for dubbing out average 10 mm thick on irregular surfaces of soffit of slab/chajjas/sunshades etc in CM 1:4 complete all as specified and directed by Engineer-in-Charge. 12 Material and labour for providing one layer of guiniting of thickness not exceeding 50 mm provided steel reinforcement and chicken wire mesh if required by means of tinned tracks or welded to existing reinforcement in CM 1:3 for top & bottom of roof slabs, beams, columns and staircase etcincl scaffolding at any height incl MSchicken wire mesh of weight exceeding 0.25 kg/sqm and n.exe 4kg/sqm complete all as specified and directed by Engineer-in-Charge. 13 Taking down Cement plaster on brick or stone walls incl raking out joints hacking for key & scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge. 14 Material and labour for 5 mm thick cement plaster in CM 1:3 as in soffits of slabs/Chajja/ Sunshade finishing the plastered surface even & smooth without using extra cement etc,complete all as specified and directed by Engineer-in-Charge. 15 Material and labour Rendering 10 mm thickon fair faces of brick work or concrete surfaces, finished even and fair (without using extra cement) on walls in cement mortar (1:6), complete all as specified and directed by Engineer-in-Charge. 16 Material and labour for rendering 15mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), using water proofing compound complete all as specified and directed by Engineer-in-Charge.NOTE: WPC will be measured and paid for separately 17 Material and labour for rendering 5mm thick in (1:3) cm on fair faces of ceiling finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. 18 Material and labour for rough cast plastering over and incl 10 mm thick rendering in cement mortar 1:3 and while it is still in plastic state the roughcast mixture consisting of crushed stone or fine gravel aggregate (which is generally of size between 6 to 12 mm depending on the texture required) mixed with coarse sand and cement in the ratio of 1: 1: 1 shall be applied and finished even. The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure that larger aggregates are thoroughly covered. Rough cast plaster shall be applied asspecified clause 14.22 of SSR Part-I, complete all as specified and directed by Engineer-in-Charge. 19 Supply only integral water proofing comound ISI Marked complete all as specified and directed by Engineer-in-Charge. 20 Material and labour for preparation of exposed brick wall surface by cleaning the surface with wire brush to remove all dirt/loose materials from the bricks and from the joints between the bricks.Prepared surface should be then washed with diluted HCL acid (dilution ratio of 1:50) for three times in a day for two days. After acid wash surface should be allowed to be air dried for one day.Note : Further treatment over the surface so achievedwill be carried out only after approval of the same by GE.Note:- This item shall be executed by authorised applicator only. for carrying out efflorescence treatment to exposed and prepared wall surfacehere–in–abovein following sequence :–(a) Prime the prepared surface with one of the following product mixed with cement in 1:1ratio as bonding agent :–(i) Pidicrete URP of M/S Pidilite (ii)Sika Latex of M/s Sika (iii) Nitobond SBR Latex of M/s FOSROC(b) Immediately after priming the surface PMM (Polymer Modified Mortar) to be applied BY HAND while the primer is tacky.PMM should be prepared by mixing one of the following compounds in Cement Mortar 1:3 as per manufacturers instructions :–(i) Pidicrete URP of M/S Pidilite (ii)Sika Latex of M/s Sika (iii) Nitobond SBR Latex of M/s FOSROC(c) PMM surface should be allowed to dry one day.After that it should be painted with two coats of one of the following compound mixed with cement only in ratio of one part of selected compound and one point fire part of cement :–(i) Pidicrete URP of M/S Pidilite (ii)Sika Latex of M/s Sika(iii) Nitobond SBR Latex of M/s FOSROC(d)Now apply two coats of one of the following compound over the surface.These compounds are to be used as per manufacturer instructions :–(i) Pidifin 2K of M/S Pidilite (ii)Brush Coat (iii) Brush Bond Note : Both coats should be perpendicular to each other and gap between two coats shall be minimum 6 hours.(e) Sprinkle loose coarse sand after second coat while surface is tacky.Note: (i) Item will be executed by authorised applicator of the selected /approved company only. (ii) Every stage of work will be approved by GE then only next layer will be executed by contractor. 21 Material and labour for applying Two or more coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS-15489:2004, Alkali & fungal resistance, dirt restance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 ltre/10 Sqm over 2mm thick wall care putty and icluding priming coat of exterior primer applied @ 0.90 litre/10 Sqm over new/Oldsurfaces complete as all specified and directed by Engineer-In-Charge. 22 Material and labour for three coats of white lime wash on new plastered surfaces of ceiling including preparation of surfacescomplete all as specified and directed by Engineer-in-Charge. 23 Material and labour for two coats of white lime wash on old plastered surfaces of ceiling including preparation of surfacescomplete all as specified and directed by Engineer-in-Charge. 24 Material and labour for preparation of new plastered surface of two coats Distempering with 1st quality acrylic distemper (ready mixed) over one coat primerover 2mm thick wall care putty having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colourcomplete , as per manufacturers specification and as specified and directed by Engineer-in-Charge. 25 Material and labour for complete removal of existing treatment ofwall Old plastered surface of Two coats Distempering with 1st quality acrylic distemper (ready mixed) over one coat primerhaving VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete , as per manufacturers specification and as specified and directed by Engineer-in-Charge. 26 Demolition of cement concrete (reinforced) inRoofs, floors (other than ground floors), beams, staircases, landing, chajjas, cooking platformand similar suspended work, complete all as specified and directed by Engineer-in-Charge. 27 Demolition ofof reinforced Cement Concrete of any description and in any positionincl cutting of reinforcement complete all as specified and directed by Engineer-in-Charge. 28 Material and labour for use and waste of form work to sides & soffits of plinth bands , lintel band, Shelves etc including, shelves etc. complete all as specified and directed by Engineer-in-Charge. 29 Material and labour for use and waste of form work to chajjas and similar work for fair finish surfaces complete all as specified and directed by Engineer-in-Charge. 30 Material and labour forreinforced cement concretetype B1 as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, cooking platformand in shelves and the like Type B1 1:2:4 (20 mm graded aggregate), complete all as specified and directed by Engineer-in-Charge. 31 Material and labour for Reinforced Cement concrete Nominal mixType B0 1:2:4 using 12.5mm graded aggregates mechanically crushedas in chajjas etc complete all as specified and directed by Engineer-in-Charge. 32 Material and labour mild steel 10 mm dia and over TMT bar cut to length, bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-Charge. 33 Material and labour mild steel 6-8 mm dia TMT bar cut to length, bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-Charge. 34 Material and labour for post anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed by the Engineer-in-Charge. 35 Material and labour for post anti termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed by the Engineer-in-Charge. 36 Material and labour for post anti termite treatment of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed by the Engineer-in-Charge. 37 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises 38 Roughening of old surfaces of old concrete floor by picking , sweeping,clean and washing down with water to remove dust etc all as directed and specified. 39 Material and labour for PCC 1:4:8 type D-2using40mm graded stone agg 75 mm thick as in sub base of floor complete all as specified and directed by Engineer-in-Charge. 40 Material and labour for 25mm thick cement concrete Type B0 1:2:4 (12.5mm graded aggregate)as in floor finished rough to recieve floor finishes etc, complete all as specified and directed by the Engineer-in-Charge. 41 Material and labour for First quality, Non skid ceramic, coloured, rectified i.e. straight edge (locally known as joint free) tiles of size 600 x 600mm each and of thickness not less than 7mm, in floors etc., set and jointed in neat cement slurry and pointed in coloured cement to matchthe shade selected quality laid over and including 15mm thick screed bedding layer in CM (1:4) complete all as specified and directed by Engineer-in-Charge. 42 Material and labour for First quality, Non skid ceramic, coloured, rectified i.e. straight edge (locally known as joint free) tilesof size 600 x 600mm each and of thickness not less than 7mm, in skirting etc. over & including 10 mm thick cement mortar (1:4) screed, set and jointed with tile adhesive with notched trowel and pointed in grout of matching shade of tiles, complete all as specified and directed by the Engineer-in-Charge. 43 Material and labourfor non skid coloured ceramic tiles 400 x 400 x 7 to 8 mm set & jointed with neat cement slurry & pointed in white/coloured cement to match the tiles over and including 15mm thick screed bed incement mortar 1:6 complete all as specified and directed by Engineer-in-Charge. 44 Material and labour for glazed ceramic colouredtiles 450x350x7 mm thick onvertical surface such as skirting , dado etc. over 10 mm thick backing coat plaster in CM 1:4 complete all as specified and directed by Engineer-in-Charge. 45 Material and labour forVitrifiedceramic tiles light shade 8 to 9mm thick (Square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floor etc set and jointed in neat cement slurry and pointed in coloured cement to matchthe shade selected quality laid over and including 15mm thick screed bedding layer in CM (1:4) make and sample as approved by GE, complete all as specified and directed by Engineer-in-Charge. 46 Material and labour for Vitrifiedceramic tiles 8 to 9mm thick (Square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in skirting/dado etc set and jointed in neat cement slurry and pointed in coloured cement to matchthe shade selected quality laid over and including 10mm thick screed bedding layer in CM (1:3) make and sample as approved by GE, complete all as specified and directed by Engineer-in-Charge. 47 Material and labour for providing and laying of 300x300 mm & 8 to 9mm thick Vitrified Pavementtile in approved color & shade and in anti skid finish set and jointed in neat cement slurry and pointed in white cement & pigment to match over and including 20 mm thick screed bed in cement mortar 1:4complete all as specified and directed by Engineer- in - Charge .(Note: Design/pattern shall be as approved by GE at the time of execution) 48 Material and labour for Machine cut Kota stone slab flooring 18-20 mm thick, laid over & including 20 mm thick screed bed in cement mortar 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (mirror finish) complete all as specified and directed by Engineer-in-Charge. 49 Material and labour for Machine cut Kota stone slab flooring 18-20 mm thickskirting, dado and pillar, laid over & including 10 mm thick rendering in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (mirror finish) complete all as specified and directed by Engineer-in-Charge. 50 Material and labour for Granite jet black shade, 16-18 mm thick, machine cut, machine polished,bedded and jointed with adhesive suitable for granite/stone & pointed with grout of matching shade including necessary cutting over & including 15 mm thick(average thickness) cement mortar(1:4) screed, as in cookingplatform,shelves,RCCcounters,windowcills&similarsituations,complete all as specified and directed by Engineer-in-Charge. 51 Material and labour for Baroda Green marble, 16-18mm thick,machine cut, laid over & including 15 mm bedded and jointed with adhesive suitable for granite/stone & pointed with grout of matching shade including necessary cutting over & including 15 mm thick(average thickness) cement mortar(1:4) screed, as in cookingplatform,shelves,RCCcounters,windowcills&similarsituations,complete all as specified and directed by Engineer-in-Charge. 52 Material and labour for Baroda Green marble, 16-18 mm thick,machine cut, laid over & including 15 mm bedded and jointed with adhesive suitable for granite/stone & pointed with grout of matching shade including necessary cutting over & including 15 mm thick(average thickness) cement mortar(1:4) screed, as in Tread of Stair case, complete all as specified and directed by the Engineer-in-Charge. 53 Rounding to edgesof stone (of any description) slabs one edge, such as in steps, cooking platform, window cill ,jamb and other similar situations including rubbing and polishing (mirror finish), complete all as specified and directed by Engineer-in-Charge. 54 Material and labour for plain cement concrete75 mm thick 1 :2 4 type B 2 using 40 mm graded stone aggregate as in flooring, finished cement concrete surface even andfair with outusing extra cement to be laid in alternate panels, complete all as specified and directed by the Engineer-in-Charge. 55 Material and labour for 40 mm thick plain cement concrete type B-1 , 1:2:4 (20 mm graded crushed stone aggregate) as in flooring finished the concrete surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. 56 Supply and fixing glass dividing strips, 3mm thick and inserted in position to conform to design and width of strip 38mm complete all as specified and directed by Engineer-in-Charge. 57 Taking down chowkaths or frames n.exc 1.5 sqm (without takingoff shutter from the frame) each and removing from the site including dismantling brick work for hold fasts, Complete all as specified and directed by Engineer-in-Charge. 58 Taking down chowkaths or frames Exc 1.5 sqm but n.exc 4 sqm(without taking off shutter from the frame) each and removing from the site including dismantling brick work for hold fasts, Complete all as specified and directed by Engineer-in-Charge. 59 Taking down chowkaths or frames not exc1.5 sqm each and removing from the site including dismantling brick work for hold fasts etc,complete all as specified and directed by the Engineer-in-Charge. 60 All as per item No 59 above but exc 1 sqm each and nexc 2 Sqm each all as specified and directed. 61 Supply and fixing of Factory made single extruded WPC (Wood Polymer Composite) solid door Frames/Chowkhat of size 125 x 65 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant , complete all as specified and directed by Engineer-in-Charge.Note: For WPC solid door frames, minus 5mm tolerance in Dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 62 All As per Ser No 61 abovebut frame size 100 x 65 mm, complete all as specified and directed by Engineer-in-Charge. 63 As per Ser No 61 abovehere in before frame size 75x 50 mm, complete all as specified and directed by the Engineer-in-Charge. 64 Supply and fixingplain, solid, straight 2nd class Hard wood chowkhats and frames, wrought, framed rebated on solid, rounded or chamferred, put together with glue pinned at joints complete all as specified and directed by Engineer-in-Charge. 65 Supply and fixing ofFactory made single extruded moulded WPC (Wood Polymer Composite) solid plain flush door shutter of 35mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ ricehusk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant, Complete all as specified and directed by Engineer-in-Charge. 66 Supply and fixing ofFactory made single extruded WPC (Wood Polymer Composite) moulded solid plain flush door shutter of 30 size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ ricehusk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant, Complete all as specified and directed by Engineer-in-Charge. 67 Supply and fixingfor 30mm thick factory made solid WPC factory made Supply and fixing glazed & Skelton shutter (wood Polymer composite) moulded gauged door shutter with wire mesh in any number of division with brown wood grain texture, square tube in side rails with screwing 8 x 28 heat metal zink coated screw can be remove or fix again after changing of wire mesh, when needed. The density of the shall be as per manufacture instruction compete all as specified and directed. 68 Supply and fixingof windows made of pre-painted steel (Base steel as per IS 513 of 0.58mm thick “D” Quality galvanized as per IS 277 with zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 72x55mm, centre mullion should be of 72x50mm, section for fixed glass beading should be of 12x12mm and section for shutter should be of 48 x 25mm. Outer frame & mullion sections to have rebate for glazed shutters, fly mesh and 20 mm provision for guard bars/ grills fly mesh shutter section should be of 20x40mm. The sections are to be cut to length mitre joined with corner bracket. Centre mullions to be fixed with mullion cap. Elixir or equivalent stay, handles 2nos of heavy duty stain less steel pivot hinges shall be provided per shutter. The windows should be paneled with 4 mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade). Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self expanding screws. Including 10mm square guard bars with 6” (152.4mm) pitch, complete for finished with suitableprovision for Window AC , complete all as specified and directed by the Engineer-in-Charge. 69 Supply and fixingof windows made of pre-painted steel (Base steel as per IS 513 of 0.58mm thick “D” Quality galvanized as per IS 277 with zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 72x55mm, centre mullion should be of 72x50mm, section for fixed glass beading should be of 12x12mm and section for shutter should be of 48 x 25mm. Outer frame & mullion sections to have rebate for glazed shutters, fly mesh and 20 mm provision for guard bars/ grills fly mesh shutter section should be of 20x40mm. The sections are to be cut to length mitre joined with corner bracket. Centre mullions to be fixed with mullion cap. Elixir or equivalent stay, handles 2nos of heavy duty stain less steel pivot hinges shall be provided per shutter. The windows should be paneled with 4 mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade). Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self expanding screws. Including 10mm square guard bars with 6” (152.4mm) pitch, complete for finished item of work including of all taxes., Complete all as specified and directed by Engineer-in-Charge. 70 Supply and fixingof ventilators made of pre-painted steel (Base steel as per IS 513 of 0.58mm thick “D” Quality galvanized as per IS 277 with zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 72x55mm, centre mullion should be of 72x50mm, section for fixed glass beading should be of 12x12mm and section for shutter should be of 48 x 25mm. Outer frame & mullion sections to have rebate for glazed shutters, fly mesh and 20 mm provision for guard bars/ grills fly mesh shutter section should be of 20x40mm. The sections are to be cut to length mitre joined with corner bracket. Centre mullions to be fixed with mullion cap. Elixir or equivalent stay, handles 2nos of heavy duty stain less steel pivot hinges shall be provided per shutter. The windows should be paneled with 4 mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade). Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self expanding screws. Including 10mm square guard bars with 6” (152.4mm) pitch, complete for finished with suitableprovision as in ventilator in toilet/bathroom/staircase, Complete all as specified and directed by Engineer-in-Charge. 71 Supply & fixing of stainless steel butt hinges 100 mm long medium weight Complete all as specified and directed by Engineer-in-Charge. 72 Supply & fixing stainless steelhandle 100mm long Complete all as specified and directed by Engineer-in-Charge. 73 Supply and fixing 150 mm longstainless steelbarrel tower boltsand fixed , complete all as specified and directed by the Engineer-in-Charge. 74 Supply & fixing stainless steel , sliding door bolt with hasp, staple (bolt type) 250 mm longand fixing with bolts extruded sections , complete all as specified and directed by the Engineer-in-Charge. 75 Supply and fixing 200 mm longstainless steel tower bolts and fixed with screw , complete all as specified and directed by the Engineer-in-Charge. 76 Supply & fixing stainless steelhandle 150 mm long complete all as specified & directed by Engineer-in-Charge. 77 Material and labour forstainless steel (Grade 304) railing made of hollow tubes,channels,plates etc, including welding,grinding ,buffing,polishing and making curvature ( whereever required) and fitting the same with necessary stainless steel nuts and bolts complete all and including fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc , of required size , on the top of floor or the side of waist slab with suitable arrangemen incl dismantling old steelall as directed by Engr in Charge. 78 Supply and Fixing steel dome 50 mm dia including polishing complete all as specified and directed by Engr-in-Charge. 79 Supply and Fixing steel cap 40 mm dia complete all as specified and directed by Engr-in-Charge. 80 Dismantling wrought iron or mild steel work of any description not otherwise provided for in any position of unframed/ framed work complete all as specified and directed by Engineer-in-Charge. 81 Supply and fixing of mild steel, framed work such as ornamental intricate design grills, grating etc with end of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing framed work of water tanks and similar work including pintal hinges, stops hand made sliding bolts etc conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-Charge. 82 Supply & fixing Mild Steel Framed work such as Guard Bar/grill welded to window frame or fixed independantlys, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, cooler stand and similar work conforming to Fe.290.Gde-E-165 complete all as specified & directed. 83 Supply and fixing0.80 mm thick mild steel plain black sheeting as in covering to door shut ters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and directed by Engineer-in-Charge. 84 Supply and fixing Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, Complete all as specified and directed by Engineer-in-Charge. 85 Supply and fixing Plain Sheet glass 3 mm thick, ordinary quality and glazing with linseed oil pane putty & spring glazing clips, in squares not exceeding 0.5 Sq. mm in each pane, complete all as specified and directed by Engineer-in-Charge. 86 Supply and fixing 3 mm thick figured glass pin head type and glazing with oil putty in sqm not exc 0.5 sqm each Complete all as specified and directed by Engineer-in-Charge. 87 Material and labour for painting to steel surfaces of any description not other wise described over 10cm width or girth with two coats of synthetic enamel paint over a coat of red oxide primer incl preparation of new surfaces complete all as specified and directed by Engr-in-charge. 88 Material and labour for painting to steel surfaces of any description not other wise described over 10cm width or girth with twocoats of synthetic enamel paint incl preparation of Old surfaces complete all as specified and directed by Engr-in-charge 89 Supply and fixing in repair300 mm MS ordinary rat tail rod pattern springs incl roller and roller plate fixed to wooden chwkhats or welded to angle iron door frames. 90 Supply and fixing in repair stainlesssteel curtain rod 25mm dia having wall thickness 1.6mmfixed with and including stainless steeldecorative brackets, two lotto for each road length at both endetccomplete all as specified and as directed by the Engineer-in-Charge. 91 Supply and fixing stainless steel peg set of 5 size 300x20x2.5mm, complete all as specified and directed by Engineer-in-Charge. 92 Supply and fixing band , straps,supports or stays for rain water, ventilating pipes including bolts, if required: hooks (stay) , heavy, for large gates: hook and pintle hinges large hasps and staples, chain hand made sliding bolts clamps hold fasts wall ties: hooks for hanging fans plain angle cleats for securing purlins to wood trusses or rafters: knee piece inserts; two ways and three way straps, plate washers and similar small articles conforming to fe-290 gde E-165, Complete all as specified and directed by Engineer-in-Charge. 93 Supply and fixing factory made mild steel door shutter with frame, fabricated from of 1 mm thickMS sheetincluding provision of steel handle & locking arrangement by providing 04 leaver lock with duplicate keys (of make Godrej, Link or Harrison) & handle etc, (all as per Godrej pattern & detail shown on Drawing No. FD-1032 sheet 1/1 dtd 25.9.93) including spray painting over a coat of red oxide primer and fixed the same on existing cupboard nitch with cement & sand mortar, incl dismantling existing door shutter , Complete all as specified and directed by Engineer-in-Charge. 94 Supply and fixing in repair stainless steel plate rack of standard size 900mmx750mm x250 mm complete and fixing with rawl plug and steel screws, Complete all as specified and directed by Engineer-in-Charge. 95 Supply and fixing stainless steel plate rack of standard size 750mmx600mm x250 mm complete and fixing with rawl plug and steel screws , Complete all as specified and directed by Engineer-in-Charge. 96 Supply and fixing rubber strips 3 to 4mm thick & 65mm to 75mm wide fixed on bottom rail of door for covering gaps between door & floor to avoid entry of insects,dust etc, complete all as specified and directed by Engineer-in-Charge. 97 Supply and fixing 140 mm overall length of cover plate Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor , complete all as specified and directed by Engineer-in-Charge. 98 Dismantling woodenboarding of any description, fixed in any position with nails as in shelves of cup board and pelmets of any description,complete all as specified and directed by Engineer-in-Charge. 99 Supply and fixing for LEAD FREE PVC Celuka ply 18mm thick (Minimum density 600kg/Cum) of both side plain white colour, fixed with stainless steel screws, solvent cement /adhesive to make kitchen /bed rooms cabinet sides top and bottom and shelves inside the cabinets complete as per manufacturer’s specifications complete all as specified and directed by Engr–in–Charge. 100 Supply and fixing for LEAD FREE PVC Celuka ply 18mm thick (Minimum density 600kg/Cum) of single side rigid lamination of approved colour and other side plain white colour, fixed with stainless steel screws, solvent cement /adhesive to make kitchen cabinet shutters and shelves complete as per manufacturer’s specifications complete all as specified and directed by Engr–in–Charge. 101 Supply and fixing for 12mm thick LEAD FREE PVC Celuka ply (Minimum density 600kg/Cum) of fixed with stainless steel screws, solvent cement /adhesive to make wall mount kitchen cabinet back and pull out drawer sides complete as per manufacturer’s specifications complete all as specified and directed by Engr–in–Charge. 102 Supply and fixing for stainless steel 304 grade wire basket cutlery of size 370 x 485mm premium quality fixed in position complete all as specified and directed by Engr–in–Charge. 103 Supply and fixing for stainless steel 304 grade wire basket (average weight 2.5 to 4 Kg per Basket) of pull out type like plain /cup & saucer /bottle /multi purpose /2–3 shelf basket etc for kitchens of required size fixed in position complete all as specified and directed by Engr–in–Charge. 104 Supply and fixing for Ball bearing runners 45mm telescopic (KTS–20) full extension load capacity minimum 50Kgs complete all as specified and directed by Engr–in–Charge. 105 Supply and fixing for ‘D’ type cabinet handles premium quality, stainless steel grade 304, gloss chrome, SN finished 150mm long matt finishedcomplete all as specified and directed by Engr–in–Charge. 106 Supply and fixing for Auto closing hinges of size 35mm of 0 crank (KH–001) of 8 crank (KH–002) openable at 110 degree for kitchen cabinet shutters complete in all respect and fixed in position complete all as specified and directed by Engr–in–Charge. 107 Supply & fixed GI tubing medium grade 15 mm dia incl fittings, cutting threading and fixing to walls or fixing in concealed walls or in floors etc,including taking up or down old tubing and making good the surfaces matching to exsiting surafaces of walls/ floor to the entire satisfaction of Engineer-in-charge. 108 Supply & fixed GI tubing medium grade 20 mm dia incl fittings, cutting threading and fixing to walls or fixing in concealed walls or in floors etc,including taking up or down old tubing and making good the surfaces matching to exsiting surafaces of walls/ floor to the entire satisfaction of Engineer-in-charge. 109 Supply & fixed GI tubing medium grade 25 mm dia incl fittings, cutting threading and fixing to walls or fixing in concealed walls or in floors etc,including taking up or down old tubing and making good the surfaces matching to exsiting surafaces of walls/ floor to the entire satisfaction of Engineer-in-charge. 110 Supply & fixing GI tubing medium grade 40 mm dia incl fittings, cutting threading and fixing to walls or fixing in concealed walls or in floors etc,including taking up or down old tubing and making good the surfaces matching to exsiting surafaces of walls/ floor to the entire satisfaction of Engineer-in-charge. 111 Cuttingchases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends of edges of landings, steps, cills etc., and cutting chases for concealed water tubing and making good , complete all as specified and directed by Engineer-in-Charge. 112 Refixing old GI tuibing 15/20mm bore galvanised with all fittings as in walls,ceilings or floors including taking up or down old tubing etc, complete all as specified and directed by the Engineer-in-Charge. 113 Supply and fixing in repairs, EWCVitreous china wash down water closet pan (Pedestal pattern), with PVC water closet seat cover , white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device white (excluding fixing bolts, flushing cistern and flush pipe, P or S trap,) , complete all as specified and directed by the Engineer-in-Charge. 114 Supply & fixingin repairsvitreous China squatting pan of “Orissa Pattern” of size 580x440mm colouredwith integral footrest complete including making good floors complete all as specified and directed by Engineer-in-Charge. 115 Supply and fixing in repair10 ltr capacity PVC valveless, syphonic action type flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, 32 mm dia flush pipe, complete all as specified and directed by the Engineer-in-Charge. 116 Supply andfixingin repair vitreous china wash hand basin white flat back of size 550x440mm including CI brackets ,chromium plated waste coupling, waste pipe and Brass CP WHB Mixer valve for mixing hot and cold water screwed down for 15mm dia etc (incl all waste fittings),complete all as specified and directed by Engineer-in-Charge. 117 Supply and fixing in repairhealth faucet ABS body with 1 metre long easy flex tube in chrome finish and wall hook, , complete all as specified and directed by Engineer-in-Charge. 118 Supply and fixing in repair Chromium plated toilet paper holder, complete all as specified and directed by Engineer-in-Charge. 119 Supply and fixing CP Water purifier RO Connecting piece for Water Bib Tap for inlet of RO etc , complete all as specified and directed by Engineer-in-Charge. 120 Supply and fixing Two way angle valve cock chromium plated brass fancy type bore 15 mm complete all as specified and directed by Engineer-in-Charge. 121 Supply and fixingtwo way bib Tap chromium plated brass fancy type of 15 mm bore , complete all as specified and directed by Engineer-in-Charge. 122 Supply and fixing chromium plated hand showerwith 1.5 mtr long flexible tube complete all as specified and as directed by engineer in charge. 123 Supply and fixing in repair CP wall mixer telephonic type , complete all as specified and directed by Engineer-in-Charge. 124 Supply and fixing for corner glass shelf with CP stand complete all as specified and directed by Engineer-in-Charge. 125 Supply and fixing in repair Towel ring square with round flange of make JAGUARor Equivalent, complete all as specified and directed by Engineer-in-Charge. 126 Supply and fixing in repair 15 mm fancy type chromium plated fancy type bib tap brass long body with flange screwed down high pressure CP cast copper alloy with crutch or butterfly handles scrwed down suitable for 15mm bore pipe or union in repair , complete all as specified and directed by Engineer-in-Charge. 127 Supply & fixed in repairs stainless steel grating openable 100mmsize with/without hole including fixing with white cement complete all as specified and directed by Engineer-in-Charge. 128 Supply and fixing in repair angle valve cock chromium plated fancy type 15 mm bore with flange make L & K code No 077A or equivalent complete all as specified and directed by Engineer-in-Charge. 129 Supply and fixing in repair 15mm bore Gun-Metal, globe or gate valves , with iron wheel head,screwed down both end for iron pipe and fixed all as specified and directed by Engineer-in-Charge. 130 Supply and fixing in repair 40mm bore Gun-Metal, globe or gate valves , with iron wheel head,screwed down both end for iron pipe and fixed all as specified and directed by Engineer-in-Charge. 131 Supply and fixing in repairStop valves, cast copper alloy, screwed down,high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, all as specified, of 15mm bore, fancy type, chromium plated with long shank and cup (Concealed type), complete all as specified and directed by Engineer-in-Charge. 132 Supply & fixedin repair fancy type shower rose125mm dia sizeof Rim and 30cm long CP brass pipe with swivel joint in complete all as specified and directed by Engineer-in-Charge. 133 Supply and fixing sheet glass shelf assembly consisting of 5.5 mm th sheet glass shelf 12 cm wide with chromium plated guard and railing 60 cm long, complete all as specified and directed by Engineer-in-Charge. 134 Supply & Fix in repair Soap dish any type, fixed to plugs with chromium plated brass screws, complete all as specified and directed by Engineer-in-Charge. 135 Supply and fixing in repair chromium plated, towel rail, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed by Engineer-in-Charge. 136 Supply and fixing in repairfor PVC connections 15mm size with PTMT nuts of length 450mm, complete all as specified and directed by Engineer-in-Charge. 137 Supply and fixing in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste pipe incl bedding in cement mortor to dwarf wall ot cantilever brackets and connecting union to pipe overall size 915x460mm, bowl size 410x 330x160mm incl all fittings ie CP waste coupling, waste pipe complete all as specified and directed by Engineer-in-Charge. 138 Supply and fixing in repair sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm, waste pipe complete all as specified and directed by Engineer-in-Charge. 139 Supply and fixing in repairs 600x450mm size bevelled edge looking mirror of selected quality glass mounted on 12mm thick marine plywood with powder coated aluminium frame alround and fixed with wooden plugs, CP screws, cup and washers, complete all as specified and directed by Engineer-in-Charge. 140 Supply and fixingPVC cabinet with looking mirror of size 350x450mm , complete all as specified and directed by the Engineer-in-Charge. 141 Demolition& breaking up drain pipes any size/ typeSWG, PVC, concrete pipe including fittings or taking out from trenches/wall/ floor , if required, complete all as specified and directed by the Engineer-in-Charge. 142 Supply and fixing for 110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls / laid in trenchesof existing pipescomplete all as specified and as directed, , complete all as specified and directed by the Engineer-in-Charge. 143 Supply and fixing PVC (SWR) 75 mm pipe type A single socket in any length with rubber ring joints laid in wall/floors or trenches, complete all as specified and directed by Engineer-in-Charge. 144 Supply and fixing in repair of PVC (SWR) bends 75 mm bore , complete all as specified and directed by Engineer-in-Charge. 145 Supply and fixing in repair of PVC (SWR) bends 110 mm bore , complete all as specified and directed by Engineer-in-Charge. 146 Supply and fixingof 110 mm bore PVC (SWR) vent cowl , complete all as specified and directed by Engineer-in-Charge. 147 Supply and fixing of PVC (SWR) floor trap 75mm dia plain with PVC grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge. 148 Supply and fixing of PVC (SWR )multi floor floor trap 110/125mm dia plain with PVC grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge. 149 Supply and fixingof PVC (SWR) junction single, (Single T) 110mm bore equal or unequal fitted with access door complete all as specified and directed by Engineer-in-Charge. 150 Supply and fixingof PVC (SWR) junction single, (Single T) 75mm bore equal or unequal fitted with access door complete all as specified and directed by Engineer-in-Charge. 151 Supply and fixing of PVC (SWR) Gully trap 125/110mm, plain with grating including seting and jointing with solvent cement complete fixed in repair all as specified and directed. 152 Supply and fixing PVC (SWR) branch piece, single (single Y) equal or unequal, complete all as specified and directed by Engineer-in-Charge. 153 Supply and fixing of stack clamps of 50mm by 5 mm flat iron and 16 mm dia round iron stays, incl bolts & nuts and securing ends of stays to wall or roof for 75 mm bore CI / PVC Pipe .,complete all as specified and directed by Engineer-in-Charge. 154 Supply and fixing of stack clamps of 50mm by 5 mm flat iron and 16 mm dia round iron stays, incl bolts & nuts and securing ends of stays to wall or roof for 100/110 mm bore CI/PVC Pipe .,complete all as specified and directed by Engineer-in-Charge. 155 Material and labour salt glazed stone ware drain pipes 150 mm bore grade ‘A’ laid in trenches and jointed in cement mortar 1:1 complete all as directed and specified. 156 Material and labour for salt-glazed stoneware gully traps,150x150 square or round mouthed, type P setting and jointing to drains with cm 1:1, complete all as specified and directed by Engineer-in-Charge. 157 Material and labour for Concrete bed to drain pipes of 100mm bore including packing under and hauching against the sides of pipes after they are laid and tested in PCC 1:3:6 type C2 , complete all as specified and directed by Engineer-in-Charge. 158 Material and labour for Concrete bed to drain pipes of 150mm bore including packing under and hauching against the sides of pipes after they are laid and tested in PCC 1:3:6 type C2 , complete all as specified and directed by Engineer-in-Charge. 159 Dismantling old unserviceable cement concrete/PVC water tanks of capacity exc 250 ltrs & n.exc 500 Ltrs including supplying & fixing of PVC water storage tank 500 ltr capacity HDPE triple layered ,white colourcylindrical type fixed and hoisted in position on roof at any height complete with inlet/outlet of 20 mm GI Pipe connection incl locking arrangement, including supplying & fixing of Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 20 mm dia(Minimum weight20 mm - 210 gms ) fixed as in repairs.Note :(i) Inlet, outlet & wash out pipe will be measured and paid for separately. 160 Disconnecting existing tanks of capacity 500 liters, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.(cleaning reparing etc measured separately). 161 Material and labour for rendering 15mm thick in CM 1:4on fair faces of brick work or concrete surface of wall and finished surface even and smooth with neeru finish to plastering , complete all as specified and directed by Engineer-in-Charge. 162 Material and labour for providingplain cement concrete 1:2:4 type B-1 (using 20mmgraded stone aggregate )as in coping/ benchingetc including necessary form work complete all as specified and directed by Engineer-in-Charge. 163 Material and labour for plain cement concrete 1:4:8 , type D-2 using 40 mm graded stone aggregate) as in foundation , filling and mass concrete ,complete all as specified and directed by Engineer-in-Charge. 164 Cleaning of sludge from the manholes by taking out loose sediment sand, girt, ash, sludge water, rags, fibres or vegetation from manholes including removal of sludge/debris to a distance exceeding 250m but not exceeding 500m and buried under groundcomplete all as specified and as directed by the Engineer-in-Charge. 165 Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150 mm dia pipe,complete all as specified and directed by Engineer-in-Charge. 166 Demolition ofof reinforced Cement Concrete of any description & in any positionincl cutting of reinforcement complete all as specified and directed by Engineer-in-Charge. 167 Material and labour for pre-cast concrete cover slabs for drain manhole/drain etc.in nominal mix 1:2:4 type B-1 (using 20 mm mechanically crushed graded stone agg)set in CM (1:6) , complete all as specified and directed by Engineer-in-Charge. 168 Demolition of cement concreteunreinforced of any description andin any position not otherwise specifically provided for, complete all as specified and directed by Engineer-in-Charge. 169 Material and labour for, 75 mm thick plain cement concrete(1:3:6) C-2 using 20mm graded stone agg in path/plinth protection finished even & smooth completed without using extra cement, complete all as specified and directed by Engineer-in-Charge. 170 Material and labour plain for cement concrete (1:3:6) C-1 using 20 mm graded stone agg as in surface channel or drain incl use of necessary from work for fair finishedsurface, complete all as specified and directed by Engineer-in-Charge. 171 Extra for forming fair finishing of drain or channel 30 cm inner girth in cement concret using extra cement including forms, moulds mitrel gloppid ends etc,, complete all as specified and directed by Engineer-in-Charge. 172 Dismantling of brick or terracing tiles of single layers on roofs incl cleaning of bricks/tiles and removal of unusable bricks/tiles and removal from site, complete all as specified and directed by Engineer-in-Charge. 173 Demolition of Mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof complete all as specified and directed by Engineer-in-Charge. 174 Material and labour for APP polymeric water proofing membrane minimum 3 mm thick and weighting not less than 3.0 Kg/Sqmblack finish reinforced with non-woven polyster matt wt not less than 150 gms/Sqm with thermo fusable finish laid over compatible bitumen primer at the rate of 0.40 Ltr/Sqm torching over laps with a propane or butane gas torch with a over lap of 75 mm at the side and 100 mm at the ends and sealing including applying a coat of cold emulsion bituminious primer all as per manufacturers instructions incl preparation of surface complete all as specified and directed by Engineer-in-Charge. Note :- The water proofing treatment shall be got carried out by the manufactarer or their authorised applictors duly approved by GE in writing. 175 Material and labour for plain cement concrete 1:2:4 type B-1, (using 20 mm graded mechanically crushed stone aggregates) as in padding to roof to maintain the required slope and finished the surface even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. 176 Material and labour for a coat of Heat resisting painting to Surfaces of any description wood, steel, iron, concrete, brick, stone, APP surface, etc., exceeding 10cm in width or girth incl preparation of APP surfaces complete all as specified and directed by Engr-in-charge 177 Material and labour for plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded mechanical crushed aggregate) for benching, coping shall be 150 mm in radius mixed with acrylic based polymer water proofing compound, complete all as specified & directed by Engineer-in-Charge.(WPC shall be paid separately) 178 Material and labour for precast plain cement concrete plain factory made tiles,22 mm thick of size 250 mm x 250 mm, fabricated using grey cement & no pigments. on 15 mm thick cement mortar (1:3) bedding and joints grouted flush in cement mortar (1:3) mixed with integral liquid water proofing compound over roof surfaces complete all as specified and directed by Engineer-in-Charge. 179 Material and labour for Roof Trusses (framed) , trussed , purlins, crane gantries, rails and fastenings and heavy bracket framing ( Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete as all spfd and directed by EIC 180 Supply and fixing in repair Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and as directedby Engr-in-charge. 181 Demolition of cement concrete (unreinforced) in ground floor and paving n.exceeding 15cm thickness (below or above GL) and disposing of debris outside MD land complete all as specified and as directed 182 Material and labour for 100mm thick plain cement concrete type D-2, 1:4:8 (40 mm graded aggregate) as in sub base complete all as specified and directed by Engineer-in-Charge. 183 Material and labour for sand filling under floor or in foundations including watering and consolidation complete all as specified as directed. 184 Material and labour for 60 mm thick coloured machine pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006 of M-35 grade with gray cement and no pigment to match complete all as specified and directed by Engineer-in-Charge. 185 Material andlabour for 5mm thick PVC hollow interlocking wall panelling of width 250mm for wall paneling forfixing on to wallwith screws and solvent alongwithcornerand u channel beadingof colour choice including dismantling old boarding/panelling all as specified and directed.sting ceiling any type including wooden filletes if any , complete all as specified and directed by Engineer-in-Charge. Note : Rate will be inclusive any elctrical board, fitting etc effected for removing & refixing and mating good to match with existing , complete all as specified and directed by Engineer-in-Charge. 186 Removing building materials etc (other than spoil payable under items 03028 to 03031 in section 3-Earthwork) to a distance of 5KM or under beyond the lead included in the rates including loading, unloading and stacking at the destination , complete all as specified and directed by Engineer-in-Charge. 187 Taking down carefully aluminium/ copper point wiring (light, fan,socket or power) complete, including fixtures and fittings such as switches, ceiling rosees, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of walls,ceilings etc, .,complete all as specified and directed by Engineer-in-Charge. 188 Taking down Ceiling fan any size or any type and deposited to MES store yard complete all as specified and directed by Engineer-in-Charge. 189 Taking down Exhaustfan any size or any type and deposited to MES store yard complete all as specified and directed by Engineer-in-Charge. 190 Taking down old unserviceable single phase Electric Meter and deposited to MES Store Yardcomplete all as specified and directed by Engineer-in-Charge. 191 Taking down old and unserviceable submain wiring any size /type including earth wire complete with batten/conduit etc complete all as specified and directed 192 Taking down old Water Heater (Geyser) any type/Size/Capacity with all accessories after removing of all incoming/outgoing pipe line connection and deposited to MES Store Yard for repair complete all as specified and directed by Engineer-in-Charge. 193 Taking down old unserviceable VPTN MCCB DB//MCB SPN 8way any of size/capacity complete all as specified and directed by Engineer-in-Charge. 194 Taking down old unserviceable MCB SPN/MCB SP of any size/capacity complete all as specified and directed by Engineer-in-Charge. 195 Material and labour for point wiring inconduit using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSHPVC insulated and unsheathed stranded cable drawn through and including PVC non metallic/mettalicheavy duty concealed/Surface conduit and including replacement of its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI sunken boxes made out of 1.2mm thick of any module from 2 to 18module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly coated with two coats of anti corrosive paint over a coat of red oxide primer internallyand externally including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over sunken box for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbedsurfaces as per existing for one light / fan/Exhaust fan point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathedFRLSH copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dollywith suitable size of lugs for one light point/ fan Point controlled by one switch , complete all as specified and directed by Engineer-in-Charge.NOTES : - 1. Switch, socket and fan regulators to be measured and paid for separately.2. All chases will be cut by chase cutter only. 196 Description all as per item No 195 here in before but for socket out let point 5 Amps on same board. complete all as specified and directed by Engineer-in-Charge. 197 Description all as per item No 195 here in before but for socket out let point 5 Amps on independentboard, complete all as specified and directed by Engineer-in-Charge. 198 Description all as per item No 195 here in before but for one two way point controlled by two switch, complete all as specified and directed by Engineer-in-Charge. 199 Description all as per item No 195 here in before but for one bell point controlled by one bell push, complete all as specified and directed by Engineer-in-Charge. 200 All as per srl item No 195 above but point wiring forone socket out let 15 & 5 Amps (independent) controlled by one switchwith using 2.5 Sq mm (nominal area) stranded copper conductor, complete all as specified and directed by Engineer-in-Charge. 201 All as per srl item No 195 above but point wiring for one Plug & socket (independent) controlled by one MCB with using 4.00 Sq mm (nominal area) stranded copper conductor for Geyser, complete all as specified and directed by Engineer-in-Charge. 202 Supply and fix in repair modularswitch 1 way 6A, 1 module ,230 volt , AC supply,complete all as specified and directed by Engineer-in-Charge. 203 Supply and fix in repair modularswitch 2 way 6 Amps,module,230 volt , AC supply, complete all as specified and directed by Engineer-in-Charge. 204 Supply and fix in repair modular switch 1 way, 16A,1 module,230 volt , AC supply,complete all as specified and directed by Engineer-in-Charge. 205 Supply and fix in repair modularsocket outlet 6A-3 Pin combined 2 module, 230 volts, complete all as specified and directed by Engineer-in-Charge. 206 Supply and fix I repair modularsocket outlet6/16 A-3 pin combined 2 modules, 230 volts, complete all as specified and directed by Engineer-in-Charge. 207 Supply and fix in repair modularfan regulator 2 modules, 120W,50 Hz, AC supply suitable for ceiling fan any type/make/sweep complete all as specified and directed by Engineer-in-Charge. 208 Supply and fix in repair modular bell push, 6 Amps one module , 230V,50Hzs, supply complete all as specified and directed 209 Supply and fixin repair call bell ding dang /musical type single pole , complete all as specified and directed by Engineer-in-Charge. 210 Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and directed by Engineer-in-Charge. 211 Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings,complete all as specified and directed by Engineer-in-Charge. 212 Supply and fixing of LED light fitting 1x20W , 220V,not less than 100 lumen per watt, AC with aluminium housing with batten type with driver , holder including 20W LED tube light for connecting up with three core flexiable copper conductor cable of suitablae size from celing rose to connector complete all as specifid and directed. Note: LED cool white/warm white must get approved from engineer-in-charge. 213 Supply and fixing LED light fitting 9/12 W wall mounting fixture (Sketch type) suitable for retrofit LED lamp B22 compact and energy efficient epoxy powder coated light luminaire including disconnecting and taking down existing unserviceable light fittings of any description complete all as specified and as directed by Engineer in-Charge. 214 Supply and fixingsurface mounted wallMirror LED light compact & sturdy10W LED decorative fixture with anti glare polycarbonate diffuser, multi purposelighting solution & applications all accessorieSupply and fixingixtures, internally prewired and connecting by providing copper flexiabkle wire 23/0.0076 mm twin core upto fitting completeall as specified and directed. 215 Supply and fixing LED surface mounted bulk head luminaries 8-10W with min 800 lumen, industrial model IP65, aluminium housing , surgeprotection including driver & LED LED etc complete with all accessories connecting with copper conductorflexiable cable from celing rose to connector of the light complete all as specified and directed by Engineer-in-Charge. 216 Supply and fixing LEDBldg security light fitting of capacity 30 Watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safty input voltage range 170 to 270 volts, with IP66 protection and other connected accessories including service bracket of MS pipe25/32mm bore of length 0.09 mtr with MS clamps, bolts, nuts and washers and suitable reducer for connecting to MS pipe as required at site and making electrical connection complete all as specified and directed by Engineer-in-Charge. 217 Supply and fixingSingle Pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCBof capacity 20 Amps, complete all as specified and directed by Engineer-in-Charge. 218 Material and labour for sub main wiring with two single core FRLSH PVCinsulatedunsheathed copper conductor cable 6.0 sq mm drawnin and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories onwall or ceiling withone additional PVC insulated , strandedcopper conductor FRLSHof 6.0 sqmm,green colourfor earthcontinuity conductor including including taking down old unserviceable sub main wiringand making good the disturbed surface complete,all as specified and directed. 219 Material and labour for sub main wiring with two single core FRLSH PVCinsulatedunsheathed copper conductor cable 4.0 sq mm drawnin and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories onwall or ceiling withone additional PVC insulated , strandedcopper conductor FRLSH of 4.0 sqmm,green colourfor earthcontinuity conductor including including taking down old unserviceable sub main wiringand making good the disturbed surface complete,all as specified and directed. 220 Supply and fixing sheet metal enclosures vertical distribution boardVTPN, (MCCB DB) 4 ways, double door , 415 volts with 200 amps rated bus bar IP 54 protection, with shrouded neutral bar and insulated bus bar and earth link, with and includingadjustable thermal setting MCCB 4 Pole, 125 Amps 25 KA as incomerand MCB sas out going complete with making suitable size of MS cabinet 2 mm thick dully grouted on the wall (flush) with opening arrangementincluding and making connection with suitable size of lugs and making good the disturbed surface matching with existing surface all as specified and dire 221 Supply , insatallation, testingofSPN distibution board 8way,double door , IP 43 , as per IS 8623including 200 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles complete all as specifid. 222 Supply and fixing MCB SP single pole, 240 volts, 50 Hz, breaking capacity , 6 to 32 Amps, complete all as specified and directed by Engineer-in-Charge. 223 Supply and fixing MCB SP single pole, 240 volts, 50 Hz, breaking capacity , 40-63Amps,complete all as specified and directed by Engineer-in-Charge. 224 Supply and fixing SPN 40 -63 Amps rating ,240 volts, 50 Hz, breaking capacity 10 KA completeall as specified and directed. 225 Taking out old unserviceable earthing and Material and labour for earthing with Galvanised Steel earth plate electrode 60cmx 60cm x 6.0 mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer ofcharcoal dust and common salt filling in alternate layers and electrode connections by usingGalvanised Earth lead wire 4.00mmdia(upto terminal point) by means ofbolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40 mm diaGI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6)type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type ofsoil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 ofSSR 1991(Part-I) complete all as specified and as directed by Engineer-in-charge. Note : The rates for earth work, GI protection pipe, funnel, wire wesh, CI cover, etc shall be deemed to beincluding in quoted rates. 226 Supply and fixing ceiling fans, AC, single phase, 230V, 50Hzs , copper wounded of 1200mm sweep with BLDC technology , max power input upto 35W , copperwire induction motor with 5 star BEE ratings alontwith canopy cover , down rod `U clamp, 3 core PVC flexiable cable 1sqmm for making connection of fan and hanging the fan in clamp, connecting with exisiting electrical connection all as specified and directed by Engineer-in-Charge. 227 Supply and fixingExhaust fan, steel body , AC single phase, 52 W, 2100 rpm,230V of size300mm . with four blades, frame and lovers complete all as specified and directed.Note: The rate of MS louvers and making 300 mm size hole (square or round)in the wall is deemed to be included in unit rate quoted. 228 Supply, installation and testing of storage type heater (Geyser) of 25 Litres Capacity, vertical type to sustain high pressure upto 8 bars with fixing bolts / fastener, necessary PCC/cement work and making good the disturbed surfaces to match with existing surface giving electric and water connection and testing after installation to entire satisfaction of the Engineer-in-Charge complete with following specifications : - (a) 5 Star rated (Vertical type) Necessary BEE cerificate from OEM shall be produced by the contractor at the time of sample approval. (b) Metal Body.(c) Glass line coated tank (Ferro-glass technology) / Polymer coated.(d) Incoloy glass coated heating element. (e) Adjustable thermostat. (f) Temperature indicator dial/digital type.(g) Multiple Heating Option. (h) Multiple Functional Safety Valve. (j) Thermal Cutout Capillary Type.NOTE : - Warranty certificate to be produced by the contractor from OEM for the following components before processing the bill.(a) For product - 02 Years (b) For metal tank 07 years. 229 Material and labourfor re-fixing single phase electric meter any type and any capacity with all accessories with making all connection complete all as specified and directed. 230 Supply and fix in repair post top lantern LED 30W , cast aluminium spigot, with high effieient LED light, with poly carbonate diffuser, complete with high efficient LED lamp 30 W and accessoriesinternally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable including disconnecting and taking down existing light fitting and removal complete all as specified and directed by Engineer-in-Charge. 231 Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium solid conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sq. mm nominal cross section in service connections, one twin core cable including all incoming and outgoing connection complete all as directed and specified. 232 NOTE:- Amount of credit ofRs. 80,051.00 for retrieved materials is mentioned in Schedule of Credit Page No 21 & 22 of tender documents in pdf form which will be deducted offline while acceptance of tender.

Key Value

Document Fees
INR 500 /-
EMD
INR 96140.0 /-
Tender Value
INR 48.07 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail