| 1 | Repair & Rennovation Work of 02 Nos Court Room, Office Constructed inNon Residential Campus of outer Court in Kalpi at Distt. Jalaun. |
| 2 | Renovation Work of Building Dismantling cement concrete or granolithic floors including base concrete and including stacking of dismantled materials as directed by Engineer-in-charge within a distance of 60 meters.(200feet) |
| 3 | Dismantling doors & windows including chaukhats with hold fast and including stacking of dismantled materials as directed by Engineer-in-charge within a distance of 60 meters.(200feet) |
| 4 | Dismantling doors & windows leaves including stacking of dismantled materials as directed by Engineer-in-charge within a distance of 60 meters.(200feet) |
| 5 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 6 | Dismantling existing plaster including disposal of refuseas directed by Engineer-in-charge within a distance of 60 meters.(200feet) |
| 7 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth. (1)1 cement : 6 coarsesand. |
| 8 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 9 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 10 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 11 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm |
| 12 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick. |
| 13 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 14 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 15 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 16 | Providing & fixing of Z-Section Windows |
| 17 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 18 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 19 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. |
| 20 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 21 | Disposal of malwa including loading & unloading Refused material within distance of 10.00 Km from site. |
| 22 | French spirit polishing : Two or more coats on new works including a coat of wood filler |
| 23 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. |
| 24 | Disposal of malwa including loading & unloading Refused material within distance of 10.00 Km from site. |
| 25 | Sanitary Work |
| 26 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid |
| 27 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 28 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Flexible pipe i) 32 mm dia |
| 29 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 30 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. |
| 31 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Circular shape 450 mm dia |
| 32 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm O.D. |
| 33 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 34 | Supply and fixing of UPVC S.W.R. door bend confirming to IS- 14735 110 mm size |
| 35 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain) 110 mm Shoe |
| 36 | Supply and fixing of UPVC S.W.R. Plain Tee confirming to IS- 14735 110x110x110 mm size |
| 37 | Supply and fixing of UPVC S.W.R. Plain bend confirming to IS- 14735 110 mm size |
| 38 | Supply and fixing of UPVC S.W.R. Door Y confirming to IS- 14735110 mm size |
| 39 | Supply and fixing of UPVC S.W.R. Cowel confirming to IS- 14735110 mm size |
| 40 | Supply and fixin g of UPVC S.W.R. Nahni trap size 100/75mm, 100/90mm confirming to IS - 14735 self cleannig design fixed in PCC 1:2:4 and supply and fixing of 125mm dia heavy duty CP brass jali. |
| 41 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms. |
| 42 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 43 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal outer dia Pipes |
| 44 | 25 mm nominal outer dia Pipes |
| 45 | 32 mm nominal outer dia Pipes |
| 46 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 15 mm nominal outer dia pipes |
| 47 | 20 mm nominal outer dia pipes |
| 48 | Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) 25mm dia, nominal bore |
| 49 | 32 mm dia, nominal bore |
| 50 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore |
| 51 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore |
| 52 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore |
| 53 | Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 15mm nominal bore |
| 54 | Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 15 mm nominal bore |
| 55 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 56 | Electrical Work |
| 57 | Wiring for circuit/ submain wiring alongwith earth wire withthefollowingsizesofFRLSPVCinsulatedcopper conductor,singlecorecableinsurface/recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 58 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 59 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 60 | Supplyingandfixingfollowingmodularswitch/socket ontheexistingmodularplate&switchboxincluding connectionsbutexcludingmodularplateetc.As required. 5/6 A switch |
| 61 | 3 pin 5/6 A socket outlet |
| 62 | Supplyingandfixingtwomodulesteppedtype electronicfanregulatorontheexistingmodularplate switch box including connections but excluding modular plate etc. as required. |
| 63 | Supplying and fixing modular blanking plate on the existing modular plate & switch boxexcluding modular plate as required. |
| 64 | Supplyingandfixingfollowingsize/modules,GIbox alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) |
| 65 | Supplyingandfixing suitable sizeGIboxwithmodular plate and cover in front on surface or in recess, including providing andfixing 3pin5/6A modularsocketoutletand 5/6 A modular switch, connections etc. as required. |
| 66 | Supplying and fixing following way, horizontal type threepoleandneutral(TPN),sheetsteel,MCB distributionboard,415V,onsurface/recess,complete withtinnedcopperbusbar,neutralbusbar,earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door |
| 67 | Supplyingandfixingoffollowingwayssurface/recess mounting,verticaltype,415V,TPNMCBdistribution board of sheet steel, dust protected,duly powder painted, inclusive of 200 A tinned copper bus bar, commonneutrallink,earthbar,dinbarformounting MCBs(butwithoutMCBsandincomer)asrequired. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door |
| 68 | Supplyingandfixing5Ato32Arating,240/415V,10 kA, \"C\" curve, miniature circuit breaker suitable for inductiveloadoffollowingpolesintheexistingMCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 69 | Supplyingandfixingsinglepoleblankingplateintheexisting MCB DB complete etc. as required. |
| 70 | Providing and fixing following rating and breaking capacityandpoleMCCBwiththermomagneticrelease andterminalspreadersinexistingcubiclepanelboard includingdrillingholesincubiclepanel,making connections, etc. as required. 100 A,30KA,FPMCCB |
| 71 | Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve.CAT A |
| 72 | Supply and fixing of40 Amp. FP MCB (10 KA) C Curve.CAT A |
| 73 | Supplyingandfixingfollowingrating,fourpole,(three phase and neutral) SPN, 415 volts, residual current circuitbreaker(RCCB),havingasensitivitycurrent30 mA in theexisting MCBDBcompletewithconnections, testing and commissioning etc. as required. 40 A |
| 74 | ProvidingandfixingM.V.dangernoticeplateof200 mmX150mm,madeof mildsteel,atleast2mm thick, andvitreousenameledwhiteonbothsides,andwith inscription in single red colour on front side as required. |
| 75 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosurewithcoverplatehavinglockingarrangement andwateringpipeof2.7metrelongetc.withcharcoal/ coke and salt as required. |
| 76 | Supplyingandlaying25mmX5mmG.Istripat0.50 metrebelowgroundasstripearthelectrode,including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlappingandwith2setsofG.I.nutbolt&spring washer spaced at 50mm) |
| 77 | Providingandlayingearthconnectionfromearth electrodewith6SWGdiaG.I.Wirein15mmdiaG.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 78 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less DirectCurrent(BLDC)Motor,classofinsulation:B,3 nos. blades, 30 cm long down rod, 2 nos. canopies, shacklekit,safetyrope,copperwinding,PowerFactor notlessthan0.9,ServiceValue(CM/M/W)minimum 6.00,Airdeliveryminimum210Cum/Min,350RPM (tolerance asperIS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and allremainingaccessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance morethan2 megaohm, suitable for 230V, 50 Hz,singlephaseACSupply,earthingetc.completeas required. |
| 79 | Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA |
| 80 | Supply andfixing of LED Tube Light fitting suitable for up to 1X22 Watt LED Tube Light on surface complete in all Respect . |
| 81 | Supply & fixingof recess mounting round10to15 wattLED down Lighter complete in all respect. |
| 82 | L.T. Switch Panel Board : Supply&Erracetionoffactoryfabricated&wiredmetal claddustandverminprooffloormounting,M.S. ChannelBasewithbottomand topcable entreise Electrical control panel with TPNMCCB\"s (Four Pole 36 KAwiththermalmagnaticrelease)SwitchesComplete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase tophasevoltageandsinglephasevoltage,currentand otherparameters(KVA,P.F,KWetc)ineachphasewith touch type selector switches for different readings, instrument fuses, current transformer etc. The panel boardshallhavesuitablecapacityelectrolytic alumininumbusbarsasperIS8623oraboveinsulated withheatshrinksleevingandmountedonnon gyroscopicsupportssuchasCMC/BMCsupportwith deteachblesidecoversandshallbesuitablefor extension on the sides. TheMCCB\"sshallbecompletewithsuitablecableend boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the boardasperdirectionsofEngineer-incharge.Allout goingsof100AmpandaboveshallhaveanAmmeter. ThepanelboardshallbefabricatedwithCRCAsheet withaminimumthicknessof1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle Type 40 Amp DP MCB - 1 Nos. |
| 83 | Renovation Work of Boundary Wall |
| 84 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 85 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 86 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 87 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 88 | Interlocking tile |
| 89 | Earthworkinexacavationintrenches forfoundationsandforpipescables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directedbytheEngineeri/cwithina lead of 50m. (2.6.1) |
| 90 | Providing and laying in cement concrete 1:4:8 (1 cement:4 coarse sand:8gradedstoneaggregate40 mm nominal size) and curing complete, includingcostofform-work,in foundation and floors. (4.1.8) |
| 91 | M-150brickworkin1:4cementand coarse sandof2.25fineness modulusmortarinfoundationand plinthincludingsupplyof all materials,labourand toolsandplants etc.required forpropercompletionof the work. |
| 92 | Supply & laying of 80 mm thick I shapped mechaniucally compressed interlockingcementconcretepavers block manufactured by high pressure & controlled vibration machine having plan dimension 200x(160+120mm) withminimum5mmthicktoppingof O.P.cementmixedwith25%marble powder.Thecompressivestrenghtof concretepaver blockshall not be less than30MPa&4.5KGno.including costofbeddingsandandjointfilling with sand all material, labour T & P etc. required for proper completion of work as directed by Engineer-in-charge. |
| 93 | GST Extra as per applicable |