| 1 | Demolition of roof treatment any thickness including APP, roof tiles, screed bed or plastering and remove the rubist materials outsideMOD land at a dumping place marked by any state govt/municipalities etc any distance complete all as specified and directed. |
| 2 | M&L Providing, cement concrete (1:2:4) type B-0 (using 12.50 mm graded stone aggregate) as in roof padding, sub base of floor coping or roof karbs on roof chamfered on edge rounded or chamfered on edges including trowelling slightly etc complete all as specified and directed. |
| 3 | M&L 15 mm thickcement plaster in CM (1:4) mixed with WPC as per manufacturer’s instructions @ 3% by weight of cement on concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid separately. |
| 4 | Supply only intergral water proofing compound ISI Marked complete all as specified |
| 5 | M&L for water proofing treatment of roof consisting as under:- (a) Applyinga tack coat of industrial bitumen 85/25 at the rate of 1.20 kg per sqm over a coat of primer @ 0.30 litre/ sq.m including preparation of roof surfaces (b) A layer of 3mm thick APP polymeric membrane of weight not less than 3.60 kg/sqm, reinforced with polyester non-woven polyester fabric (weight not less than 160gm/sqm), duly sealed at over laps & joints with flame (by torch application) all as per manufacturer’s instructions complete all as specified and directed. |
| 6 | M&L for applying two coat of bitumenous aluminium paint over APP membrane complete all as specified and directed |
| 7 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description in any position not specifically provided complete all as specified and directed. |
| 8 | M&L Providing, reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in chajjas and the like etc complete all as specified and directed. |
| 9 | M&L for TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hopping for columns,hooking ends and binding with and including MS wire (annealed) not less than 0.90 mm dia confirming to TMT bars complete all as specified. |
| 10 | M&L for form work to soffits of suspended slabs such as roof slabs, florslabs, landings and similar work not exceeding 200 mm thick rough finished in flat surface complete all as specified. |
| 11 | M&L for form work to edges of concrete flats, treads, break in floor window cills, concrete raillings, opening in concrete walls floor and roofs n.exc 20 cm wide and sides of RCC/PCC bands in walls, horizon tal or sloping and similar work exc 5 cm but not exc 10 cm wide rough finished surface complete all as specified. |
| 12 | Taking up or down steel tubing and connections 15mm dia pipes including cleaning for refixing or removal from site complete all as specified and as directed. |
| 13 | Taking up or down steel tubing and connections 20mm dia pipes including cleaning for refixing or removal from site complete all as specified and as directed. |
| 14 | S & F 15 mm bore Galvanized Steel tubes, medium grade with all fittings forwater supply pipes etc., laid in trenches/fixed on walls. |
| 15 | S & F 20 mm bore Galvanized Steel tubes, medium grade with all fittings forwater supply pipes etc., laid in trenches/fixed on walls. |
| 16 | Refixing old steel tubing and connections 15mm dia in new or old position (walls, ceiling, floors etc). |
| 17 | Refixing old steel tubing and connections 20mm dia in new or old position (walls, ceiling, floors etc). |
| 18 | Dismantlingwatertanks Capacity of tank exc250 & n. exc 500 ltrs removing complete all as specified and as directed |
| 19 | Dismantlingwatertanks Capacity of tank exc500 & n. exc 1000 ltrs removing complete all as specified and as directed |
| 20 | Supply and fixingrotational moulded polyethylene three layered water storage tanks 500 litres capacity (cylindrical,vertical with closed top) hoisted and fixed in position all as specified and as directed. |
| 21 | Supply and fixingrotational moulded polyethylene three layered water storage tanks 1000 ltrs capacity (cylindrical,vertical with closed top) hoisted and fixed in position all as specified and as directed. |
| 22 | Disconnecting existing PVC water tank of capacity upto 500 ltrs, setting aside or lowering down if required for repairs of roof treatment, hoisting and reconnecting and refixing in position on roof including cleaning of overhead tank & removing the sludge washing down with detergent/bleaching powder without distrubing pipe line system and float valve/refixing of float valve and making functional after cleaning and writing letter \"Tank cleaned on_____ (date, month and year)” boldly with thick white/black/yellow synthetic enamel paint complete all as specified and as directed . |
| 23 | Disconnecting existing PVC water tank of capacity exc. 500 ltrs but n. exc 1000 ltrs, setting aside or lowering down if required for repairs of roof treatment, hoisting and reconnecting and refixing in position on roof including cleaning of overhead tank & removing the sludge washing down with detergent/bleaching powder without distrubing pipe line system and float valve/refixing of float valve and making functional after cleaning and writing letter \"Tank cleaned on_____ (date, month and year)” boldly with thick white/black/yellow synthetic enamel paint complete all as specified and as directed . |
| 24 | S & F in repair for Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed,Bore dia of pipe in 20 mm, etc complete all as specifed and directed. |
| 25 | S&F in repairs 20mm dia gun metal gate valve, with iron wheel head, screwed both ends for iron pipes complete all as directed by Engr in Charge. |
| 26 | Dismantling Asbestos cement sheet (corrugated, semi corrugated etc), plain or corrugated steel sheet in roof coverings complete all as specified. |
| 27 | S&F for pre-painted Galvalume aluminium Zinc cooating GI based corrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 mpa as in covering/cladding to wall fixed with self tapping screws all as specified and directed. |
| 28 | Fixing onlypre-painted Galvalume aluminium Zinc cooating GI based corrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified and directed. |
| 29 | S&F for pre-painted Galvalume aluminium Zinc cooating GI based Plain steel sheet 0.5 mm thick of any colour having tensile strength of 550 mpa as in covering/cladding to wall fixed with self tapping screws all as specified and directed. |
| 30 | Fixing only pre-painted Galvalume aluminium Zinc cooating GI based Plain steel sheet 0.5 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified and directed. |
| 31 | S&F in repair false ceiling with exposed GI system using “SILHOUETTE XL 15 mm (Nominal) designer Grid \"Armstrong\"white or Global white with black reveal and 600 x 600 x 15 mm thick prime fine fissured micro look white/coloured tiles (superfine 15mm/silhouette). Making necessary framework for AC ducting, if any and necessary cutouts for diffusers and light fittings, taping and finishing to proper line & level and incl dismantling old undervicable false ceillingcomplete all as per manufacturer’s instructions and as directed. |
| 32 | Taking down aluminium door/window/partition shutter including chowkhat of area not exc. 1.50 Sqm complete all as specified and directed by Engineer-in-Charge. |
| 33 | Taking down aluminium door/window/partion shutter including chowkhat of areaexc. 1.50 Sqm but n.exc 4.00Sqm complete all as specified and directed by Engineer-in-Charge. |
| 34 | S&F powder coated aluminium frame work fordoors, windows,partition s etc incl grill for windows for windows etc with one or more rebated section incl jointing cleats for fixingetc complete complete. |
| 35 | S&F powder coated anodised aluminium door shutters, partition wall, aluminium section weighting 0.55 Kg/Rm incl necessary joining cleats glazing clips rubber neoprene packing, handles two Nos in each door, hinges anodised aluminium snap beading screws etc complete all as specified and as directed. |
| 36 | S&F powder coated anodised aluminium window and ventilator shutters , sliding type with & without sash bars aluminium section weighting 0.55 Kg/Rm incl necessary joining cleats glazing clips rubberpacking, aluminium anodised snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (1Nos0, hinges type B-21 100 mm long(2Nos) suitable handles (1Nos)complete all as specified and as directed. |
| 37 | S&F Powder coated aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge. |
| 38 | M & L for repair of Aluminium door shutters, including taking down, re-setting easing, fixing of cleats, screws, nuts, bolts, door closers, hold fasts, Aluminium door stopper, change of PVC rubber beadings, repair for smooth functioning of door and refixing in same opening all as specified and directed. |
| 39 | S&F in repairs Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing ports made of brass , other parts made of mild steel heavy duty and finishing the disturbed surface to match with existing finish complete all as specified and directed by Engr-in-Charge. |
| 40 | S & Fin repair brass mortice lock vertical type size 100 /150mm 4/6 levers all as specified and directed by Engr-in-Charge |
| 41 | Hacking out old broken glass (any thickness, size, quality or description) from metal / Aluminium frames including punching or drilling out old glazing pins/ spring clips complete all as specified anddirected. |
| 42 | S&F 5.5 mm thick Sheet glass, ordinary quality and glazing with oil putty / Aluminium rubber beading in squaresexceeding 0.5 Sq.M in each pane complete all as specified anddirected |
| 43 | S&F 4 mm thick sheet glass ordinary quality and glazing wooden fillets / rubber beading in squares as directed and specified. |
| 44 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15cm thickness (below or above ground level).all as specified and directed. |
| 45 | M&L for PCC (1:3:6) Type C-2 50 mm thick using 40 graded stone aggregate as in subbase of floor all as specified. |
| 46 | M&L for 100 mm thick Cement concrete type C1, 1:3:6 (using 40 mm gradedaggregate) infoothpaths andhard standingfinish even and fair without using extra cement complete all as specified and directed. |
| 47 | M&L for 75 mm thick Cement concrete type C2 1:3:6 (using 40 mm gradedaggregate) inplinth protection etc finished even and smooth without using extra cemen complete all as specified and directed. |
| 48 | Material and labour for Forming Contraction (Dummy) joints 65mm deep x 10mm wide,grade Bfilled with sealing compound as in pavings,hardstanding etc all as spd and dirceted by the Engr In Charge. |
| 49 | S&F in repairs, stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed to steel frames with tinned tacks, or galvanized wire staples, or fixed to wooden frames with first class hard wood bead,complete all as specified and directed. |
| 50 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth, including removal of rubbish outside MoD land complete all as specified. |
| 51 | S & F in repair 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed. |
| 52 | S & F in repair 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed. |
| 53 | Demolition of brick workbuilt in cement mortar incl all quoins, arched, pillars etc but excl ashlar facings, dressed stone work and precast concretecomplete all as specified and directed by Engineer - in - Charge. |
| 54 | M&L Brick work with sub class \"B\" Bricks, straight or curved on plan to any radius as in half brick thick wall in CM 1:4 completeall as specified and directed by Engineer - in - Charge . |
| 55 | M&L Brick work with sub Class ‘B’ bricks straight or curved on plan exceeding 6 mm mean radius built in cement mortar 1:4, complete all as specified. |
| 56 | Taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, including removal of rubbish outside MoD land, complete all as specified and directed. |
| 57 | M&L Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:4) finished fair and even without using extra cement, complete all as specified and directed. |
| 58 | M&L Rendering 10 mm thick on brick or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement, complete all as specified and directed. |
| 59 | M&L Rendering 10 mm thick in cement mortar (1:3), as on concrete surfaces (such as top & sides of chajjas, beams, balcony ceiling etc.) finished even and smooth without using extra cement, complete all as specified and directed. |
| 60 | M&L for 3mm thick white wall putty on new/old surfaces of walls & making the surfaces fair and smooth complete all as specified and as directed by Engr-in-charge. |
| 61 | M&L for preparation of newly plastered surfaces of wall and applying two coats of wheather proofing exterior emulsion paint over a coat ofprimer complete all as specified and as directed. |
| 62 | M&L for preparation of newly plastered or unplastered/undecorated surfaces of ceiling and applying twocoats of oil bound distemper over a coat ofprimer complete all as specified and as directed. |
| 63 | M&L for preparation of newly plastered surfaces of wall and applying two coats of exterior emulsion paint over a coat ofprimer complete all as specified and as directed. |
| 64 | M&L for reparation of old surfaces of walls including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc.; rubbing down and stopping of surfaces using sand paper and applying one coat of oil bound distemper, complete all as specified and directed. |
| 65 | M&L for preparation of old surfaces of ceiling including cornices by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc, filling cracks/holes with putty and applying one coat of oil bound distemper, complete all as specified and directed. |
| 66 | M & L forcomplete removal of existing treatment from old plastered surfaces of celing and applying two coats of Asian paints Royale Shyne paint (coloured/white) over a coat ofdeco prime primer over and including one coats of wall care putty with brush/roller, finished even and smooth complete all as per manufacturer\"s instruction and as directed by GE. |
| 67 | M & L forcomplete removal of existing treatment from old plastered surfaces of walls and applying two coats of Asian paints Royale Shyne paint (coloured/white) over a coat ofdeco prime primer over and including one coats of wall care putty with brush/roller, finished even and smooth complete all as per manufacturer\"s instruction and as directed by GE. |
| 68 | M&L for preparation of old surfaces of walls by washing rubbing down and stopping of surface and applying one coats of cement base paint complete all as specified and directed. |
| 69 | M&L for preparation(complete removal of existing treatment) of old decorated external wall/ceiling surface of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7\"/9\" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying Two coats of wheather proofing exterior acrylic emulsion paint over priming coat premium quality on wall/ceiling surface including applying 2mm thick wall care putty over disturbed surface during preparation of any reason, sand papering thus make surface smooth upto 4th storey buildings complete all as specified and directed. Note : (a) Stage for Preparation of surfaces shall be got approved from Engg-In-Charge before applying the finishes.(b) Material shall be procured from manufacturer and work shall be got executed through authorised applicator. |
| 70 | M&L for preparation(complete removal of existing treatment) of old decorated external wall/ceiling surface of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7\"/9\" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying Two coats of wheather proofing exterior acrylic emulsion paint (Camouflage Pattern) over priming coat premium quality on wall/ceiling surface including applying 2mm thick wall care putty over disturbed surface during preparation of any reason, sand papering thus make surface smooth upto 4th storey buildings complete all as specified and directed. Note : (a) Stage for Preparation of surfaces shall be got approved from Engg-In-Charge before applying the finishes.(b) Material shall be procured from manufacturer and work shall be got executed through authorised applicator. |
| 71 | Material and labour for preparation of old painted surfaces of steel of any description and girth, not otherwise described and treated with one coat of synthetic enamel paint complete all as directed.Make of Paint : Asian(Apcolite)/ Nerolac (Goodlass)/ Berger paints/ICI Dulux |
| 72 | Material and labour, Gunniting to existing RCC Chajja, facia, parapet, beams, landings and similar RCC members after removing all loose concrete & preparations of surface, application of derusting chemical such as Dr Fixit Rust Remover or equivalent, welding additional bars/welded steel wire fabric if found necessary, priming reinforcement bars with a coat of zinc primer of coating not less than 40 micron, provision of bonding agent with bonding material like Dr Fixit bonding agent and repair to external RCC structure with slurry light and steel/ply form work and shortcrete concrete of mixed 1:3:1 (one part of cement, three part of coarse sand and one part of 10mm and down aggregate) of minimum 50mm thick incl plastering 5 mm thick in CM mortar 1:3all as specified in IS 9012-1978 (all priming and bonding epoxy based paint shall be of Dr Fixit epoxy zinc primer or equivalent) etc complete all as specified and directed, as below:- Note(s) : 1. The rates include for necessary formwork and scafolding etc. 2. Reinforcement and welded steel wire fabric will be measured and paid separately. |
| 73 | S&F in repairs steel rolling shutter 1.25 mm thickness of laths without ball bearing as specified incl top cover archoring rod, hasp & staple and shop coat of primer erected in position as indicated complete push pull or manual type including taking down of old shutter completeall as specified and directed by engineer in charge. |
| 74 | - Ditto - but gear operated type with bevel gear box and crank handle. |
| 75 | S&F sefty lever lock MS with 04 levers for rolling shutters complete all as specified and directed by engineer in charge. |
| 76 | S&F ball bearing for rolling shutters complete all as specified and directed. |
| 77 | M&L greasing and servicing (overhauling) of steel rolling shutter of manual type of any size incl greasing and survives of ball bearing,hood cover anchoring rod hasp and staple completeall as specified and directed by engineer in charge. |
| 78 | M&L greasing and servicing (overhauling) of steel rolling shutter of gear operated type of any size incl greasing and survives of ball bearing,hood cover anchoring rod hasp and staple completeall as specified and directed by engineer in charge. |
| 79 | M&L replacing unserviceable rolling shutter spring of any size incl taking down and refixing rolling shutter in same condition if required completeall as specified and directed by engineer in charge. |
| 80 | Dimantling Interlocking paving tiles/brick tiles etc any description and tiles laid in dry complete all as directed |
| 81 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specifed and directetd. |
| 82 | M&L for sand filling under interlocking tiles or in foundations, spread and levelled including watering and consolidation complete. |
| 83 | S&F Factory made machine pressed Chequered cement concrete colour tiles30 cm X30 cm X22 mm thick, with grey cement andpigments, set, jointed and pointed in neat cement slurry in floors , over 20 mm thickscreed bed in CM 1 :4complete all as specified and as directed. |
| 84 | Excavation in post holes (or similar holes) in soft/disintegrated rock each n. exc 0.5cum, getting out, returning filling in and ramming earth or brocken rubble mixed with earth arround in layers not exc 25cm watering and removing surplus soil to a distance n. exc 50m and making good surfaces etc Complete all as specified and directed |
| 85 | M&L for plain cement concrete type B-2, 1:2:4 (40mm graded stone aggregate) as in foundations, filling and mass concrete etc Complete all as specified and directed |
| 86 | Dismantling wrought iron or mild steel work of any description all as specified and directed by Engineer - in - Charge . |
| 87 | S& F for Hand rails, half round or other steel section or core for wooden hand-rail straight portion,drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wiremesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165etc complete all as spd and directed. |
| 88 | S & F steel work in mild steel trusses, rafters and posts etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 (grade st-240) complete all as specified and directed by Engineer - in - Charge. |
| 89 | S&F Framed work as in doors orgates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hook sand hinges or steel hangingdoor fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete. |
| 90 | S&F 1.60 mm thick mild steel, plain black sheet in wall cladding, steel gates and similar work, cut to size holes punched, including round headed screws, clout nails or rivet and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams including bending or turming up mitred angles etc as required all as specified and directed |
| 91 | M&L Preparation new steel surface of any description not other wise described over 10 cm width or girth and applying two coat of synthetic enamel paint over one coat of red oxide complete all as specified. |