Tender For Provision Of Md Accommodation At Tezpur Military Station Under Ge (N) Tezpur; 1 BUILDINGS & STRUCTURE (Sch A PART-I) 2 Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE”as listed in Schedule ‘A’ Part-I.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 86,52,29,000.00inserted by the MES in Schedule ‘A’ Part-I. 3 EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch A PART-II) 4 Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT”as listed in Schedule ‘A’ Part-II.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 39,03,451.78 inserted by the MES in Schedule ‘A’ Part-II. 5 INTERNAL WATER SUPPLY (Sch A PART-III) 6 Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-III.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 52,58,866.28inserted by the MES in Schedule ‘A’ Part-III. 7 INTERNAL ELECTRIFICATION (Sch A PART-IV) 8 Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-IV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 2,13,21,973.40 inserted by the MES in Schedule ‘A’ Part-IV. 9 ROAD, PATH, CULVERT & HARDSTANDING (Sch A PART-V) 10 Lump sum price worked out by the Contractor for “(ROAD, PATH, CULVERT & HARDSTANDING)”as listed in Schedule ‘A’ Part-V.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 1,26,27,883.00 inserted by the MES in Schedule ‘A’ Part-V. 11 SEWAGE DISPOSAL (Sch A PART-VI) 12 Lump sum price worked out by the Contractor for “(SEWAGE DISPOSAL)”as listed in Schedule ‘A’ Part-VI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 28,27,973.03inserted by the MES in Schedule ‘A’ Part-VI. 13 AREA DRAINAGE(Sch A Part-VII) 14 Lump sum price worked out by the Contractor for “(AREA DRAINAGE)”as listed in Schedule ‘A’ Part-VII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 37,29,719.29inserted by the MES in Schedule ‘A’ Part-VII. 15 EXTERNAL WATER SUPPLY (Sch A Part-VIII) 16 Lump sum price worked out by the Contractor for “(EXTERNAL WATER SUPPLY)”as listed in Schedule ‘A’ Part-VIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 8,27,538.00 inserted by the MES in Schedule ‘A’ Part-VIII. 17 EXTERNAL ELECTRIFICATION(Sch A PART-IX) 18 Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-IX.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 90,42,816.18inserted by the MES in Schedule ‘A’ Part-IX. 19 FIRE FIGHTING (Sch A Part-X) 20 Lump sum price worked out by the Contractor for “(FIRE FIGHTING)”as listed in Schedule ‘A’ Part-X.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 57,13,063.16 inserted by the MES in Schedule ‘A’ Part-X. 21 STP (Sch A Part-XI) 22 Lump sum price worked out by the Contractor for “(STP)”as listed in Schedule ‘A’ Part-XI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs.15,57,138.06inserted by the MES in Schedule ‘A’ Part-XI. 23 LIGHTNING PROTECTION & DG SET (Sch A Part-XII) 24 Lump sum price worked out by the Contractor for “(LIGHTNING PROTECTION AND DG SET) ”as listed in Schedule ‘A’ Part-XII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 5,21,128.90inserted by the MES in Schedule ‘A’ Part-XII. 25 LIFT (Sch A Part-XIII) 26 Lump sum price worked out by the Contractor for “(LIFT)”as listed in Schedule ‘A’ Part-XIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,50,64,975.70 inserted by the MES in Schedule ‘A’ Part-XIII. 27 AVIATION OBSTRUCTION LIGHT (Sch A Part-XIV) 28 Lump sum price worked out by the Contractor for “(AVIATION OBSTRUCTION LIGHT)”as listed in Schedule ‘A’ Part-XIV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 44,646.95 inserted by the MES in Schedule ‘A’ Part-XIV. 29 TELE/TV SOCKET (Sch A Part-XV) 30 Lump sum price worked out by the Contractor for “(TELE/TV SOCKET)”as listed in Schedule ‘A’ Part-XV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,13,408.80 inserted by the MES in Schedule ‘A’ Part-XV. 31 CHAIN LINK FENCING (Sch A Part-XVI) 32 Lump sum price worked out by the Contractor for “(CHAIN LINK FENCING)”as listed in Schedule ‘A’ Part-XVI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 9,28,684.57 inserted by the MES in Schedule ‘A’ Part-XVI. 33 MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch A Part-XVII) 34 EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENTBringing approved Earth may be mixed with granules / pebbles not exceeding 40 mm size (as approved by Garrison Engineer) from sources outside defence land including all cost such as royalty if any, transportation, taxes if any etc. complete all as specified and directed.NOTE :-(a) Earth required for the item shall be supplied by contractor from outside of MOD land at any lead, at his own arrangement.(b) All cost of procurement of earth including cost of transportation, compaction royalties, tax etc shall be deemed to be included in the unit rate quoted by the contractor.(c) Forming embankments / filling in low lying areas including raising (or lowering) earth, spreading in layers not exceeding 30 cm thick, watering ramming / rolling and finishing of required size, shape etc not exceeding 1.5 m high from base / natural ground level.(d) With reference to Clause 3.6 of MES Schedule Part-II on Serial Page No. 21, it is clarified that measurement of the above item shall be of finished embankment / traverse of filled earth after consolidation / compaction and 5% deduction shall be made from measured and calculated volume to allow for increase in bulk.(e) Total quantity / partial quantity of earth may not be available in Sevoke Area. The contractor shall bring the earth outside area and it is advised to quote the rate considering available of soil and its lead involved. 35 INTERNAL WATER SUPPLYS & F 15 mm health faucet, chromium plated, fancy type with 1.0 m steel flexible complete suitable for 15 mm inner dia CPVC pipe complete all as specified and as directed.Note: The maximum flow rate will be 03 LPM 36 S & F 15 mm dia bib tap two way, fancy type screwed down and fixed suitable for 15 mm inner dia CPVC pipe complete all as specified and as directed.Note: The maximum flow rate will be 03 LPM 37 S & F swivel shower with arm of 15 mm dia, 195 mm long with bend of 45 degrees with flange of fancy type, chromium plated, screwed down and fixed suitable for 15 mm inner dia pipe complete all as specified and as directed. Note: The maximum flow rate shall be 03 LPM 38 INTERNAL ELECTRIFICATIONS&F Modular type 3/5 pin socket including plug top 16 A controlled by switch 16A including sheet metal enclosure suitable for Geyser point complete all as specified and directed. 39 Supply and fix 5 watt LED lamp capable to output 501 lm with lamp holder B22 type complete all as specified and directed. 40 Supply and fix 9 watt LED lamp with wall mounted decorative fitting complete all as specified and directed.MAKE :Philips Grace wall light modal No. 91921585005 or equivalent. 41 S & FTPN DB 6 way (vertical type), double door IP 43 with acrylic door as per IEC 61439-3 sitable for flush/surface mounting with 100Amp fully insulated Copper Busbar for each phase with 2 shrouded Neutral bar, 2 Earth bar and cable ties, prefitted masking sheet, reversible Doorwith provision for FP MCB/RCBO as incommer and SP/SPN MCBs as outgoing without MCBs complete all as specified and directed. 42 S&F SPN DB with sheet metal enclosure240 volts 6 way, single phase, double door with copper bus bar neutral link, earth link, earthing studs without MCBs complete all as specified and directed. 43 S&F Hot press molded SMC meter box of size not less than 700mm X 480mm x 210mm for accommodating 04 nos of single/three phase prepaid energy meter including cutting the wall surfaces for flush mounting of meter box and making good to match with the existing surfacecomplete all as specified and directed. 44 ROAD, PATH, CULVERT & HARDSTANDINGS&F Road Safety convex mirror of size 600mm dia having polycarbonate body, unbreakable orange colour including mountined over metalic stand not less than 65mm dia pipe duly painted of standard height 150cm. All steel parts black powder coated to make all weather resistant. The same is embedded in ground with 300 X 300 X 300 mm size PCC of (1:2:4) including necessary excavation, the cost is included in the item complete all as specified and directed.MAKE : Honesty Automation Private Limited, GREENS/GREENLITE, 3M, Ladwa, Adstar, Fasteck Metro Plus or Equivalent. 45 Providing & laying 8 to 10mm thick, heavy duty non skid coloured digital printed floor tiles of size 300mmX300mm, set and jointed in neat cement slurry and pointed with white cement with pigment to match the tiles colour over and including 15mm thick screed bedding in CM (1:6) and dismentling of existing tiles/blocks of any discription complete in all respect as specified and directed. 46 S & F Sign board of minimum size 1.20 Sqm with 1mm thick hexagonal pattern retro reflective self adhesive plastic sticker sheet of approved colour as per size, design, pasted on 3mm thick aluminium composite panel exterior grade sheet including laser cutted figures such as direction signs, photoes, words including necessary stainless steel nut bolts fixed on stainless steel hollow section pipe of dia 50mm, Overall height above GL not less 1.50m and embedded in PCC (1:4:8) upto 450mm depth in any type of soil complete all as specified and directed. 47 S & F mandatory Sign board with 1mm thick hexagonal pattern retro reflective self adhesive plastic sticker sheet of approved colour as per size, design, pasted on 3mm thick aluminium composite panel exterior grade sheet including laser cutted figures such as direction signs, photoes, words including necessary stainless steel nut bolts fixed on stainless steel hollow section pipe of dia 50mm , Overall height above GL not less 1.50m and embedded in PCC (1:4:8) upto 450mm depth in any type of soil complete all as specified and directed. 48 SEWAGE DISPOSALSupply, laying, jointing and testing of 150mm internal diameter of double wall corrugated (DWC) high density polyethylene pipe (HDPE) and stiffness classes -8 (SN-8) with ISI marked (with CML no) and including all fitting of pipe & jointing material for sewage line and laid in trenches all as specified in IS -16098-2013 part-2 complete all as specified and directed. 49 M&L for precast RCC heavy duty RCPC manhole cover & frame of clear opening 600 mm including fixing with CM (1:4) complete all as specified and directed. 50 STEEL GATEM&L for construction of MS steel gate of size 5.5m x 2.00m with RCC pillar on either side of gate including all necessary excavation, earth work, PCC foundation, reinforcement comprising of 8 Nos 12 mm TMT bar main reinforcement and 8mm dia. stirrups @ 150mm C/C including formwork, plaster 15mm thick in CM (1:4) with surface, Granite/ marble stone on RCC pillar/column, Arch shape MS steel plate over column with decorated Lettercomplete all as specified and shown on TD Drg No. CESZ/2018/TD-27 dated 08 Aug 2018, Sheet 1/3 to 3/3. 51 AVIATION OBSTRUCTION LIGHTSupply and fix aviation obstruction light LED type comprising of aluminium housing with polycarbonate enclosure complete all as specified and directed.MAKE : Bajaj Cat No BGAV 302 LED or equivalent Make mentioned in list of products. 52 Supply and fix MCB SPN 6-32 Amps, 10 KA, C curve complete all as specified and directed. 53 TELE/TV SOCKETSupply and fix TV socket 1 module complete all as specified and directed. 54 Supply and fix Tele socket 1 module complete all as specified and directed. 55 Supply and fix inner and outer modular cover plate of 1/2 M complete all as specified and directed. 56 EXTERNAL WATER SUPPLYSupply, jointing and laying in trenches in standard lenght, centrifugally cast (spun) ductile iron (Dl) pressure pipes, S/S type, 150 mm dia with inside cement mortar lining and black bitumen external coating, nominal daimeter, class K-7 classification, confirming to IS-8329 (ISI marked), including push on and rubber gasket joints and jointing including testing complete all as specified and directed. 57 Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains of size 150 mm dia complete all as specified and directed. 58 Supply and fix Monoblock pump set suitable for 415 V, 3 phase system having capacity 15 HP, 40 mtr head complete all as specified and directed.NOTE : Provn of necessary sheet cover protection for each pump set shall be provided by the contractor. Cost of the same is deemed to be included in the quoted rate. 59 M&L for construction of valve pit of internal size 120 cm x 120 cm x 100 cm with one brick thick brick masonary wall in cement mortar (1:4) PCC foundation 15 cm thick (1:4:8) type D-2 with 15 cm offsets, PCC copping 5 cm thick (1:2:4) type B-1, plastering 15 mm thick in cement mortar (1:4), 40x40x6mm angle iron frame and 3mm thick MS sheet cover with locking arrangement including painting to steel surfaces wtih two coats of synthetic arrangement including painting to steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer and necessary excavation and earth work complete all as specified and directed. 60 Labour only for cutting of CI/DI/GI pipe 100 to 200 mm dia carefully in position for repairs or inserting fittings such as valve, bend, tee, socket pieces, collar etc complete all as specified and directed. 61 Material and labour for horizontal boringunder roads/path for insertion of pipes upto 200 mm bore by manual drilling complete all as specified and directed. 62 Supply, fixing & testing factory made and CPRI tested indoortype Floor mounted self supporting. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 300 Amps for phases & neutral mounted on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-65 class protection and fabricated out of 2 mm CRCA sheet duly powder coated after seven tank process. The panel shall befront openable type adequate space all around cessories suchas LT switch gear and metering instruments including internal wiring in the panel with FRLS non flamable insulated multi stranded/ solid copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practicesand comprising of followings acessories.(i) INCOMING (a) MCCB 415 Volts,32-63Amp rating, 4 Pole microprocessor based (Service Breaking Capacity 16 kA 1 Nos. (b) Digital multi function meter (V,A,Hz,Pf) with and including resin cast CTs - 01 Set.(c) Phase indicating lamp(setof3).(II) OUTGOING (a) MCB 415 Volts,32Amp , rating 3 Pole, (Service Breaking Capacity 10 kA)-02 No.(b) Star delta starter suitable upto 15 Hp auto starter pump set-02 No (as per pump capcity)(b) Internal wiring of panel with stranded copper cable of suitable size (c) LED indicating lamp(Set ofthree)-01 Set (d) All standard relays and contactors to make the motor and pump operational in auto, manual and test mode including power cable from control panel to motor. Note: Scope of work also includes un foreseen items such as laying / passing of cable through walls/ floors/ pipes over/ beneath the surface, drilling holes core cutting etc aredeemed to be included in unit quoted rate. 63 EXTERNAL ELECTRIFICATIONMaterial and labour for horizontal boringunder roads/path for insertion of pipes upto 100 mm boreby manual drilling complete all as specified and directed. 64 Supply and fix junction box made out of polycarbonate with IP 55/1P 66 protection of suitable size including - 04 Nos cable terminal, 02. Nos polycarbonate cable gland, 01 Nos DIN rail and 01 No. MCB SP. 10 KA 6 Ampsincl 01 pair of clamp made out of MS flat 25 X 3 mm, nuts bolts and washers incl painting of clamps and nuts, bolts and washers with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. 65 M&L for street light bracket made out of 32 mm dia GI pipe light grade 1.2 mtr long cut to size and to shape, fixing to steel tubular swaged LT poles with flat iron clamps of size 40X6mm 02 sets incl nuts, bolts and washers incl two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed 66 Supply, Installation, testing and commissioning of LT panel board outdoor cubicle type suitable for 3 phase , 4 wire 415 volt 50 Hz factory fabricated CPRI type tested powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron section 50x50x6mm frame with front and back openable double door system with locking arrangement louver and air vent gasket for natural air flow of air with canopy, inner compartment made out of 2 mm thick CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arrangements with aluminium bus barof cap 1200 amps three phase and neutral suitable capacity marked RED,YELLOW, BLUE and BLACK insulators, made of high strength insulated materials 1100 voltage, bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity, lifting lugs (02 Nos) ,arrangement to be connect earthing strip at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The panel should be chemically treated with 07 tank metal treatment process for anticorrosive treatment. The panel shall be completely dust and vermine proof and degree of protection not less than IP-55 and general construction confirming to IS -1347 epoxy powder coated and the control circuit shall be connected bymulti stranded copper conductor flexible wire not less than 1.5 Sqmm in proper colour coding and drawn through in flexible conduit. All internal connection should be made by using copper strip/wire of suitable size and provision cable entry/exitshall be provided at the bottom / sideof the panel for both incoming/outgoing cable connectionby using suitable size of cable gland, thimbling , grouting of the panel to PCC foundation PCC-M10 using 20 mm graded stone aggregate complete with following accessories all as specified and directed :- Item Contined as Ser No. 17.34 67 (a) 1200 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code(b)Incommer - ACB 4 pole, 800 Amps, breaking capacity 65 kA. - 01 nos (c) OutgoingMCCB 4 pole,400 Amps, breaking capacity 50 kA - 02 Nos(1 x Offr Md Accn Panel + 1 x Spare)(d) Outgoing- MCCB 4 pole,200 Amps, breaking capacity 36 kA.- 04 Nos (2 x JCO Md Accn Panel + 1 x DG Panel + 1 x Spare(e)Three Ph Digital Volt Meter(0-500)Volt with selector switch. - 01Nos(f) Three Ph Digital Ammeter with CTs with appropriate Ratio along with selector switch.- 05 Nos(g) Digital frequency meter 50 Hz - 01 No(h) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase,01 Each Set(k) PCC Foundation 68 Supply, Installation, testing and commissioning of LT panel board outdoor cubicle type suitable for 3 phase , 4 wire 415 volt 50 Hz factory fabricated CPRI type tested powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron section 50x50x6mm frame with front and back openable double door system with locking arrangement louver and air vent gasket for natural air flow of air with canopy, inner compartment made out of 2 mm thick CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arrangements with aluminium bus barof cap 400 amps three phase and neutral suitable capacity marked RED,YELLOW,BLUE and BLACK insulators, made of high strength insulated materials 1100 voltage, bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity, lifting lugs (02 Nos) ,arrangement to be connect earthing strip at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The panel should be chemically treated with 07 tank metal treatment process for anticorrosive treatment. The panel shall be completely dust and vermine proof and degree of protection not less than IP-55 and general construction confirming to IS -1347 epoxy powder coated and the control circuit shall be connected bymulti stranded copper conductor flexible wire not less than 1.5 Sqmm in proper colour coding and drawn through in flexible conduit. All internal connection should be made by using copper strip/wire of suitable size and provision cable entry/exitshall be provided at the bottom / sideof the panel for both incoming/outgoing cable connectionby using suitable size of cable gland, thimbling , grouting of the panel to PCC foundation PCC-M10 using 20 mm graded stone aggregate complete with following accessories all as specified and directed by Engr-in-charge :-Item Contined as Ser No. 17.36 69 (a) 400 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code(b) Incomer - MCCB 4 pole,200 Amps, breaking capacity36 kA.- 01 Nos(c) Outgoing - MCCB 4 pole,63 Amps, breaking capacity 16 kA . - 03 Nos(2x W/S pump panel through stabilizer + 1x spare)(d) Outgoing - MCCB 4 pole,32 Amps, breaking capacity 16 kA . - 14 Nos( 2x Offr Md Accn Lift + 6x JCO Md Accn Lift + 3 X Fire pump Panel + 1x street light + 2x Spare) (e) Outgoing - MCB SPN, 16 Amps, breaking capacity 10 KA-16 Nos. (9x staircase+ 3x common area+ 3 x aviation light+ 1x spare). (f) Street light timer switch -01 Nos(g)Three Ph Digital Volt Meter(0-500)Volt with selector switch. - 01Nos(h) Three Ph Digital Ammeter with CTs with appropriate Ratio along with selector switch. - 01 Nos(j) Digital frequency meter 50 Hz.-01 Nos(k) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase,01 Each Set(l) PCC Foundation 70 Supply, Installation, testing and commissioning of LT panel board outdoor cubicle type suitable for 3 phase , 4 wire 415 volt 50 Hz factory fabricated CPRI type tested powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron section 50x50x6mm frame with front and back openable double door system with locking arrangement louver and air vent gasket for natural air flow of air with canopy, inner compartment made out of 2 mm thick CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arrangements with aluminium bus barof cap 400 amps three phase and neutral suitable capacity marked RED,YELLOW,BLUE and BLACK insulators, made of high strength insulated materials 1100 voltage, bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity, lifting lugs (02 Nos) ,arrangement to be connect earthing strip at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The panel should be chemically treated with 07 tank metal treatment process for anticorrosive treatment. The panel shall be completely dust and vermine proof and degree of protection not less than IP-55 and general construction confirming to IS -1347 epoxy powder coated and the control circuit shall be connected bymulti stranded copper conductor flexible wire not less than 1.5 Sqmm in proper colour coding and drawn through in flexible conduit. All internal connection should be made by using copper strip/wire of suitable size and provision cable entry/exitshall be provided at the bottom / sideof the panel for both incoming/outgoing cable connectionby using suitable size of cable gland, thimbling , grouting of the panel to PCC foundation PCC-M10 using 20 mm graded stone aggregate complete with following accessories all as specified and directed by Engr-in-charge :-Item Contined as Ser No. 17.38 71 (a) Incomer - MCCB 4 pole,200 Amps, breaking capacity 36 kA.- 01 Nos(b) Outgoing - MCCB 4 pole,63 Amps, breaking capacity 16 kA . - 03 Nos(2x W/S pump panel through stabilizer + 1x spare)(c) Outgoing -MCCB 4 pole, 32 Amps, breaking capacity 16 KA-16 Nos. (10x OR Md Accn Lift+ 4x Fire pump Panel+ 1x street light+ 1x spare). (d) Outgoing - MCB SPN, 16 Amps, breaking capacity 10 KA-11 Nos (6x staircase+ 2x common area+ 2x aviation light+ 1x spare).(e) Street light timer switch -01 Nos(f)Three Ph Digital Volt Meter(0-500)Volt with selector switch. - 01Nos(g) Three Ph Digital Ammeter with CTs with appropriate Ratio along with selector switch. - 01 Nos(h) Digital frequency meter 50 Hz.-01 Nos(j) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase,01 Each Set(k) PCC Foundation 72 Supply, Installation, testing and commissioning of LT panel board outdoor cubicle type suitable for 3 phase , 4 wire 415 volt 50 Hz factory fabricated CPRI type tested powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron section 50x50x6mm frame with front and back openable double door system with locking arrangement louver and air vent gasket for natural air flow of air with canopy, inner compartment made out of 2 mm thick CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arrangements with aluminium bus barof cap 600 amps three phase and neutral suitable capacity marked RED,YELLOW,BLUE and BLACK insulators, made of high strength insulated materials 1100 voltage, bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity, lifting lugs (02 Nos) ,arrangement to be connect earthing strip at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The panel should be chemically treated with 07 tank metal treatment process for anticorrosive treatment. The panel shall be completely dust and vermine proof and degree of protection not less than IP-55 and general construction confirming to IS -1347 epoxy powder coated and the control circuit shall be connected bymulti stranded copper conductor flexible wire not less than 1.5 Sqmm in proper colour coding and drawn through in flexible conduit. All internal connection should be made by using copper strip/wire of suitable size and provision cable entry/exitshall be provided at the bottom / sideof the panel for both incoming/outgoing cable connectionby using suitable size of cable gland, thimbling , grouting of the panel to PCC foundation PCC-M10 using 20 mm graded stone aggregate complete with following accessories all as specified and directed by Engr-in-charge :-Item Contined as Ser No. 17.40 73 (a) 600 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code(b) Incommer -MCCB 4 pole,400 Amps, breaking capacity 50 kA.- 01 Nos(c) Outgoing - MCCB 4 pole, 125 Amps, breaking capacity 25 kA.- 06 Nos (1x Each Floor - 05 Nos + 1x Spare)(d)Three Ph Digital Volt Meter(0-500)Volt with selector switch.- 01Nos(e) Three Ph Digital Ammeter with CTs with appropriate Ratio along with selector switch.- 01 Nos(f) Digital frequency meter 50Hz.01 No(g) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase,01 Each Set(h) PCC Foundation. 74 Supply, Installation, testing and commissioning of LT panel board outdoor cubicle type suitable for 3 phase , 4 wire 415 volt 50 Hz factory fabricated CPRI type tested powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron section 50x50x6mm frame with front and back openable double door system with locking arrangement louver and air vent gasket for natural air flow of air with canopy, inner compartment made out of 2 mm thick CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arrangements with aluminium bus barof cap 300 amps three phase and neutral suitable capacity marked RED,YELLOW,BLUE and BLACK insulators, made of high strength insulated materials 1100 voltage, bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity, lifting lugs (02 Nos) ,arrangement to be connect earthing strip at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers.The panel should be chemically treated with 07 tank metal treatment process for anticorrosive treatment. The panel shall be completely dust and vermine proof and degree of protection not less than IP-55 and general construction confirming to IS -1347 epoxy powder coated and the control circuit shall be connected bymulti stranded copper conductor flexible wire not less than 1.5 Sqmm in proper colour coding and drawn through in flexible conduit. All internal connection should be made by using copper strip/wire of suitable size and provision cable entry/exitshall be provided at the bottom / sideof the panel for both incoming/outgoing cable connectionby using suitable size of cable gland, thimbling , grouting of the panel to PCC foundation PCC-M10 using 20 mm graded stone aggregate complete with following accessories all as specified and directed by Engr-in-charge :-Item Contined as Ser No. 17.42 75 (a) 400 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code(b) Incommer - MCCB 4 pole,200 Amps, breaking capacity 36 kA.- 01 Nos(c) Outgoing - MCCB 4 pole,63 Amps, breaking capacity 16 kA.- 07 Nos (1x Each Floor - 06 Nos + 1x Spare)(d)Three Ph Digital Volt Meter(0-500)Volt with selector switch.- 01Nos(e) Three Ph Digital Ammeter with CTs with appropriate Ratio along with selector switch.- 01 Nos(f) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase,01 Each Set(g) PCC Foundation. 76 Supply, Installation, testing and commissioning of LT panel board outdoor cubicle type suitable for 3 phase , 4 wire 415 volt 50 Hz factory fabricated CPRI type tested powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron section 50x50x6mm frame with front and back openable double door system with locking arrangement louver and air vent gasket for natural air flow of air with canopy, inner compartment made out of 2 mm thick CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arrangements with aluminium bus barof cap 1000 amps three phase and neutral suitable capacity marked RED,YELLOW,BLUE and BLACK insulators, made of high strength insulated materials 1100 voltage, bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity, lifting lugs (02 Nos) ,arrangement to be connect earthing strip at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers.The panel should be chemically treated with 07 tank metal treatment process for anticorrosive treatment. The panel shall be completely dust and vermine proof and degree of protection not less than IP-55 and general construction confirming to IS -1347 epoxy powder coated and the control circuit shall be connected bymulti stranded copper conductor flexible wire not less than 1.5 Sqmm in proper colour coding and drawn through in flexible conduit. All internal connection should be made by using copper strip/wire of suitable size and provision cable entry/exitshall be provided at the bottom / sideof the panel for both incoming/outgoing cable connectionby using suitable size of cable gland, thimbling , grouting of the panel to PCC foundation PCC-M10 using 20 mm graded stone aggregate complete with following accessories all as specified and directed by Engr-in-charge :Item Contined as Ser No. 17.44 77 (a) 1000 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code(b)Incommer - ACB 4 pole,800 Amps, breaking capacity 50 kA, - 01 Nos (c) OutgoingMCCB 4 pole, 200 Amps, breaking capacity 36 kA.- 05 Nos (4x OR Md Block +1x Spare.(d) OutgoingMCCB 4 pole,200 Amps, breaking capacity36 kA.- 02 Nos (1x DG Panel + 1x Spare) (e)Three Ph Digital Volt Meter(0-500)Volt with selector switch..- 01Nos(f) Three Ph Digital Ammeter with CTs with appropriate Ratio along with selector switch. - 01 Nos(g) Digital frequency meter 50 Hz - 01 No.(h) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase,01 Each Set(l) PCC Foundation . 78 Supply, Installation, testing and commissioning of LT panel board outdoor cubicle type suitable for 3 phase , 4 wire 415 volt 50 Hz factory fabricated CPRI type tested powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron section 50x50x6mm frame with front and back openable double door system with locking arrangement louver and air vent gasket for natural air flow of air with canopy, inner compartment made out of 2 mm thick CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arrangements with aluminium bus barof cap 300 amps three phase and neutral suitable capacity marked RED,YELLOW,BLUE and BLACK insulators, made of high strength insulated materials 1100 voltage, bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity, lifting lugs (02 Nos) ,arrangement to be connect earthing strip at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers.The panel should be chemically treated with 07 tank metal treatment process for anticorrosive treatment. The panel shall be completely dust and vermine proof and degree of protection not less than IP-55 and general construction confirming to IS -1347 epoxy powder coated and the control circuit shall be connected bymulti stranded copper conductor flexible wire not less than 1.5 Sqmm in proper colour coding and drawn through in flexible conduit. All internal connection should be made by using copper strip/wire of suitable size and provision cable entry/exitshall be provided at the bottom / sideof the panel for both incoming/outgoing cable connectionby using suitable size of cable gland, thimbling , grouting of the panel to PCC foundation PCC-M10 using 20 mm graded stone aggregate complete with following accessories all as specified and directed by Engr-in-charge :-Item Contined as Ser No. 17.46 79 (a) 400 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code(b) Incommer - MCCB 4 pole,200 Amps, breaking capacity 36 kA.- 01 Nos(c) Outgoing - MCCB 4 pole,63 Amps, breaking capacity 16 kA.- 07 Nos (1x Each Floor - 06 Nos + 1x Spare)(d)Three Ph Digital Volt Meter(0-500)Volt with selector switch.- 01Nos(e) Three Ph Digital Ammeter with CTs with appropriate Ratio along with selector switch.- 01 Nos(f) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase,01 Each Set(g) PCC Foundation. 80 M&L for block masonry transformer platform of size 1.5 mtr x 1.5 mtr with height 1.2 mtr above and 60 cm below GL consisting of cement concrete in foundation of PCC 1:4:8 type D2 using 40 mm graded stone aggregate, PCC block masonry work, Sub base concrete with PCC 1:3:6 and 100mm thick top PCC 1:2:4 type B2 and 15 mm plaster on side walls in 1:4 CM incl 2 coats of white wash and providing 2 Nos supporting channel of ISMC 100 of 1.2 mtr long complete all as specified and directed. 81 S&F chain link MS Galvanized fencing 64 RM length, height 2 mtr and 3mm / 4mm dia GI wire and 100 x 100 mm mess, angle or Tee section ( 40x 40 x 5 mm) fixed independently, with connecting plates for fencing post incl necessary drilled holes, bend to shape at top as directed for fencing post of the transformer yard and mild steel round bars 10 mm dia as in horizontal line wires of chain link fencing of quality Fe – 290 (Gde E- 165) making curve wall of 300 mm height around the substation with pre cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar type CM 1:6, plaster on side walls 1:4 CM 15 mm thick incl provn of steel gate of size 2 mtr x 1.8 mtr fabricated out of MS angle iron/ rods with locking arrangementcomplete all as specified and as directed. 82 S & F LT cable route markers made out of PCC (1:3:6) type C1 using 20mm graded stone aggregate size 600 x 300 x 100 mm thick (30 cm buried in ground with DANGER/440 V LT UG CABLE embossed on marker including excavation and earth work complete all as specified and as directed. 83 S & F HT cable route markers made out of PCC (1:3:6) type C1 using 20mm graded stone aggregate size 900 x 300 x 100 mm thick (60 cm buried in ground with DANGER/11 KV UG CABLE embossed on marker including excavation and earth work complete all as directed. 84 Supply installation, testing and commissioning of servo controlled voltage stabilizer (conforming to BIS 9815 (Part-1): 1994, reaffirmation 2019 latest version). Three phase, four wire (RYBN), 50Hz, naturally oil cooled indoor, unbalanced type, copper wound core (CRGO M4 grade/CRNO), metallic body duly powder coated with lifting hooks two Nos., digital display type, relay free smooth and silent operation with first filling of Transformer oil (IS 335) up to level having following specification:- (a) capacity 200 KVA(b) Input voltage 360 V- 480 Volts(c) Desired output voltage 415+1%(d) Wave form distortion - Nil(e) Response time - not to exceed 20 milli secondsItem Continued as 17.52 to 17.53 85 (f) Sensitivity - ±1%(g) Rate of correction - Not less than 6 Volt/second between phase and neutral.(h) Efficiency = More than 95%(j) Metering - Digital display voltmeter/Ammeter with multi functional meter (k) Operating temperature - max 55 degrees Celsius.(l) Class of insulation - Class F(m) Mode of operation - Automatic/manual Winding temperature rise -Max 55 Degree Celsius (10 degree Celsius above operating temp)(n) Auto transformer (Variac) - 100 percent Copper wound Electrolytic grade(o) Power factor-Not less than 0.95(p) Losses - As per IS 86 (q) Protection:-(i) Over load protection(ii) Short circuit protection(iii) High/Low voltage cut off(iv) By pass arrangement in case of emergency.(v) Earth fault protection(r) Standard Fittings and accessories eg marking plate, lifting lugs, CI Rollers, Earthing terminal etc, cable box. 87 DG SETSupply, installation, testing, and commissioning of silent built in within an acoustic enclosure diesel engine driven generating set complied with latest CPCB Normsengine as per IS 10001/10002 and Alternator as per IS 13364 water cooled for power supply 415 volts, 03 Phase, 4 wire, 50 cycles / sec, Pf - 0.8, 100 KVACapacity complete with alternator directly coupled to diesel engine, mounted on common base frame & complete with self starter, fuel tank capacity not less than 08 hours fuel requirement & battery as per OEM, battery leads, sound proof canopy etc. with features for automatic shutdown in the event ofa circuit failure condition arising from low oil pressure, high coolant temperature, over speed etc. & microprocessor based genset includingOEMin built fitted AMF panelwith the following under-mentioned features & all as specified & as directed :-a) Alphanumeric LCD display with LED backlightb) Operator interface.c) Suitable to provide a record of most recent fault conditions & fault history.d) Complete alternator data viz, voltage ph - ph, ph - neutral, KVA, frequency etc.e) Complete engine data viz, starting battery voltage, engine temp, engine running hours, engine oil pressure etc.f) Control including provn of service adjustment & calibration of DG control functions.(A) Genset shall have followings Specifications : Prime mover Rating : 100 KVA/80 KW No of Phase : 03Power Factor: 0.8 (LAG) Item Contined as Ser No. 17.55 to 17.56 88 (B) Engine Specification : Cooling: Water cooledAspriation : Turbo Charged after cooledRPM : 1500Governer : Mechanical (C) Alternator specifications : Voltage : 415 VoltRPM / Frequency : 1500 / 50 HZEnclosure : IP 23Voltage regulation (Max) : +/- 1 %Insulation class : H Class(D) Make of Engine : Cummins/ Kiloskar green/ Ashoka Leyland(E) Make of Alternator : Stamford/ Kirloskar.Make of Battery : Exide/AMCO.(F) Size/type/Number of battery : As per manufacturere (OEM) recommendations.(G) OEM manufacutured Inbuilt type AMF Panel with suitable size MCCB - 02 Nos ( DG incomming and Main Incomming), heavy duty3 Pole contractor, Auto Manual switch, Digitial Amper Meter & Volt meter- 02 Sets (for DC battery current and AC for Mains), 3 Phase Indicators , CT`s , Suitable rating aluminium bus bar complete. Note:- (i) Anything missed out in the technical specifications but technically required for efficient working of DG Set is deemed to be included in the quoted rates.(ii) The quoted rate shall be deemed to be inclusive of first fill of engine oil & final successful acceptance test. 89 (iii) The quoted rate shall be deemed to be inclusive of 12 Hrs test run at site as specified in the PS in presence of rep of Accepting Officer; all testing arrangements / equipment’s, resistive load including POL shall be made available by the contractor.are to be included. (iv) The quoted rate shall be deemed to be inclusive of the PCC foundation required for placing the DG set and it should be as per the manufacturers recommendation.(v) Contractor shall submit the specification of DG set and take prior take approval from GE before procurement of DG set.(vi) Contractor shall produce the plateform drg form OEM and take approval of GE.(vii) Contractor shall produce all test certifacte and Purchase voucher before claming the payment.(viii) AMF panel shall be inbult type as per OEM specification. 90 Supply, installation, testing, and commissioning of silent built in within an acoustic enclosure diesel engine driven generating set complied with latest CPCB Norms engine as per IS 10001/10002 and Alternator as per IS 13364 water cooled for power supply 415 volts, 03 Phase, 4 wire, 50 cycles / sec, Pf-0.8, 15 KVACapacitycomplete with alternator directly coupled to diesel engine, mounted on common base frame & complete with self starter, fuel tank capacity not less than 08 hours fuel requirement & battery as per OEM, battery leads, sound proof canopy etc. with features for automatic shutdown in the event ofa circuit failure condition arising from low oil pressure, high coolant temperature, over speed etc. & microprocessor based genset includingOEMin built fitted AMF panelwith the following under-mentioned features & all as specified & as directed :-( STP 100KLD)a) Alphanumeric LCD display with LED backlightb) Operator interface.c) Suitable to provide a record of most recent fault conditions & fault history.d) Complete alternator data viz, voltage ph - ph, ph - neutral, KVA, frequency etc.e) Complete engine data viz, starting battery voltage, engine temp, engine running hours, engine oil pressure etc.f) Control including provn of service adjustment & calibration of DG control functions.(A) Genset shall have followings Specifications : Prime mover Rating : 15 KVA/12 KW No of Phase : 03Power Factor: 0.8 (LAG) Item Contined as Ser No. 17.58 to 17.59 91 (B) Engine Specification : Cooling: Water cooledAspriation : Turbo Charged after cooledRPM : 1500Governer : Mechanical (C) Alternator specifications : Voltage : 415 VoltRPM / Frequency : 1500 / 50 HZEnclosure : IP 23Voltage regulation (Max) : +/- 1 %Insulation class : H Class(D) Make of Engine : Cummins/ Kiloskar green/ Ashoka Leyland(E) Make of Alternator : Stamford/ Kirloskar.Make of Battery : Exide/AMCO.(F) Size/type/Number of battery : As per manufacturere (OEM) recommendations.(G) OEM manufacutured Inbuilt type AMF Panel with suitable size MCCB - 02 Nos ( DG incomming and Main Incomming), heavy duty3 Pole contractor, Auto Manual switch, Digitial Amper Meter & Volt meter- 02 Sets (for DC battery current and AC for Mains), 3 Phase Indicators , CT`s , Suitable rating aluminium bus bar complete. 92 NOTE :-(i) Anything missed out in the technical specifications but technically required for efficient working of DG Set is deemed to be included in the quoted rates.(ii) The quoted rate shall be deemed to be inclusive of first fill of engine oil & final successful acceptance test.(iii) The quoted rate shall be deemed to be inclusive of 12 Hrs test run at site as specified in the PS in presence of rep of Accepting Officer; all testing arrangements / equipment’s, resistive load including POL shall be made available by the contractor.are to be included. (iv) The quoted rate shall be deemed to be inclusive of the PCC foundation required for placing the DG set and it should be as per the manufacturers recommendation.(v) Contractor shall submit the specification of DG set and take prior take approval from GE before procurement of DG set.(vi) Contractor shall produce the plateform drg form OEM and take approval of GE.(vii) Contractor shall produce all test certifacte and Purchase voucher before claming the payment.(viii) AMF panel shall be inbult type as per OEM specification. 93 FIRE FIGHTINGSupply and fix automatic air release valve 100mm dia suitable for domestic water with 100 mm gun metalstop valve complete all as specified and directed. 94 Factory made and CPRI tested outdoortype wall mounted on wall brackets. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 300 Amps for phases & neutral mounted on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-65 class protection and fabricated out of 3 mm CRCA sheet duly powder coated after nine tank process. The panel shall befront openable type adequate space all around cessories suchas LT switchgear and metering instruments including internal wiring in the panel with FRLS non flamable insulated multi stranded/ solid copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practicesand comprising of followings acessories.Panel shall be mounted on 40x40x6mm angle iron frame and painted with fire red colour. Item Contined as Ser No. 17.62 95 (i) INCOMING (a) MCCB 415 Volts,32-63Amp rating, 4 Pole microprocessor based (Service Breaking Capacity 16 kA 1 Nos. (b) Digital multi function meter (V,A,Hz,Pf) with and including resin cast CTs - 01 Set.(c) Phase indicating lamp(setof3).(II) OUTGOING (a) MCB 415 Volts,32Amp , rating 3 Pole, (Service Breaking Capacity 10 kA)-02 No.(b) Star delta starter suitable upto 15 Hp auto starter fire pump set-02 No (as per pump capcity)(b) Internal wiring of panel with stranded copper cable of suitable size (c) LED indicating lamp(Set ofthree)-01 Set (d) All standard relays and contactors to make the motor and pump operational in auto, manual and test mode tomeet the pressure of 3.5 Kg per cm2 atterrace level. An auxulary switch to start the motor from desired locationto test the motor and pressure from ground floor shaft. Control cables from Pressure switch to control panel, From control panel to Auxilary switch (FRLS armoured) and power cable from control panel to motor. Note: Scope of work also includes un foreseen items such as laying / passing of cable through walls/ floors/ pipes over/ beneath the surface, drilling holes core cutting etc aredeemed to be included in unit quoted rate. 96 Supply and fix FRLS armoured cable copper conductor 2 x 1.5 Sqmm with ISI marked complete all as specified and directed. 97 S&F wall mounted LED emergency Exit signage luminaire Lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours complete all as specified and directed. 98 Supply and installation, testing and commissioning of net workable Analog Addressable type Active Loop Repeater (Loop power/external power) Fire terminal with inbuit turbo isolator, Backlit LCD Display 6x40 characters display,having Controls For Reset, Mute, Accept , Silence alarms and Self Test, with programmable free keys and Duly Approved byEN54/LPCB/VDS/FM complete all as specified and directed. Make: SIEMENS/NOTIFIER/ BOSCH 99 Supply, installation, testing and commissioning of PA console panel (8 zone) having all types of indication, LCD display, selector switches and fitted with 350 Watt Amplifier with individual call/all call with Gooseneck Micro phone of AHUJA complete with all accessories all as specified and directed. 100 Supply, installation, testing and commissioning loud speaker 4 watts wall mounting typecomplete all as specified and directed. 101 Supply, installation, testing and commissioning talk back panel (8 zone) with in built mike wall mounting type complete all as specified and directed. 102 M & L for fire point including civil works such as PCC foundation and galvalume sheet cover shed duly painted complete all as specified and directed consisting of the following:(a) Fire extinguisher dry chemical powder (ABC) type (light weight stored pressure type) 6 Kg capacity as per IS 15683 - 01 No.(b) Fire extinguisher mechanical foam type (light weight stored pressure type) 9 Ltr capacity as per IS 15683 - 01 No.(c) Fire extinguisher CO2 type (light weight squeeze grip type) 4.5 kg capacity as per IS 15683 - 01 No. 103 S&F Fire extinguisher dry chemical powder (ABC) type (light weight stored pressure type) 6 Kg capacity as per IS 15683 complete all as specified and directed. 104 S&F Fire extinguisher CO2 type (light weight squeeze grip type) 4.5 kg capacity as per IS 15683 complete all as specified and directed. 105 LIFTSupply and fix 4 pole MCCB 32 Amp, 50 Hz, 415 volt breaking capacity 25 KA incl suitable sheet metal enclosure complete all as specified and directed. 106 STPDesign, Supply, construction, installation, testing & commissioning of Package type Sewage Treatment Plant 100KLD Capacity comprising of the following items:-(i). Bar Screen(Mesh)MOC: MSEP/SS304 ,Fine Screen Mesh size 06mm - 01 No(ii) Raw Sewage Pump - 02Nos(1W+1S) Type :Non clog sewage submersibleMake: Crompton/Kirloskar/EquivallentHead: 10m Flow : 5cum/hr(minimum)(iii) Diffuser -24Nos Type :Tubular type MOC:Silicon Size: 63 mm dia X 600mm Make : CWC/Cheston (iv) MBBR Media-12 cumSize: 63mm diaX10mmMOC : PPSpecific Gravity : 0.95 to 1 Surface Area : 190sqm/Cum Make Yogeshwar Pastic or equivalent make(v) TubeSettler - 6.35cumSize: 700mm MOC : PVC Type : Honey Comb Type Item Contined as Ser No. 17.74 to 17.78 107 (vi) Filter Feed Pump - 02Nos (1W+1S) Type : Centrifugal Pump Make : Lubi/Kirloskar/KDS Pump Head : 40 mFlow : 5cum/Hr(vii) Treated WaterPump - 02Nos (1W+1S) Type : Centrifugal Pump Make : Lubi/Kirloskar or equivalent makeHead : 30 mFlow : 5cum/Hr(viii) Air Blower - 02Nos (1W+1S) Type : Twin Lobe RootType Both side oil cooling Suction at Top and Discharge at BottomMake :Airvak or equivalent makeCapacity : 110 cum/hr Pressure : 0.4kg/Sqcm(ix) Air Piping - 01 Lot Non submerged piping: MS/GI/uPVCSubmerged piping : uPVCMake of UPVC: Kishan/Astral/Supreme/FinolexMake of MS/GI : Standard available. 108 (x)Liquid Piping - 01 Lot Non submerged piping: uPVC - Sch - 40Submerged piping : uPVC - Sch-40Make : Kishan/Astral/Supreme/Finolex(xi) Control Panel - 01 NoType of Panel : Automatic panel of micro controller base HMI Size :7 Housing: MS with powder coating with minimum 1.6mm sheetMode of operation ; Automatic/Manual Make of Panel :Enviro EngineersAll working + Standby equipment will be change over automatic in case trip on equipment as well as cascade in operation. Blowers with VFD with auto operation of DO meter. All Motor should show individual Amp in HMI. Real time data logger for fault checking. Fault indicator like Under load, Over load, reverse phase, Single phase preventer(xii) Pressure Sand Filter - 01 No MOC of Filter : FRP Design Pressure: 10Kg/Sqcm Operation Presure : 4Kg/Sqcm. Capacity : 5cum/hr Make of pressure vessel :Pentair or equivalent make Multiple Valve : Automatic in operation through Pressure Transmitter 109 (xiii)Activated Carbon Filter - 01 No MOC of Filter : FRP Size of Filter : 330 mm dia x 1350 m HtDesign Pressure : 10 Kg/Sqcm, Operation Pressure : 4 Kg/Sqcm, Capacity : 5 Cum/hrMake of pressure vessel :Pentair or equivalent make Multiple Valve : Automatic in operation through Pressure Transmitter(xiv) Disinfected Dosing System - 01 NoDosing Pump make : Vision/Verito . Type: Metering Type Capacity of Dosing Pump : 0-4LPHNos of Dozing Pump : 02 (1W+1S) Dosing tank make : Spectron/Eqivallent, Nos of Dozing Tank: 01 No Dosing tank capacity : 100KLDDosing tank MOC : LDPE Make :Spectron/Sintex or equivalent make(xv)PressureGauge - 04 Nos Range ; 0-7kg Make ; Brinda/Vision/La/EquivallentType : Bottom mounted(xvi) Pressure Transmitter - 03 NosRange : 0-10kg Make : Boumer/ARTACK/DanfossType : Bottom mounted 110 (xvii) Level Sensor - 05Nos Type : Float type level sensors(xviii) DO Meter - 01 NoType : Optical type Range : 0-20ppmNo maintenance type(xix) Ultra Filtration : 01 NoFlow : 5cum/hrMake of UF : MOWS/Drop Saver QuaNo of Module : 01 No(xx) UF Backwash Pump - 02 Nos (1W+1S) Type : Centrifugal pump Make : LUBI/Kirloskar/KDS PumpHead : 40mFlow : 15 cum/hr(xxi) Centrigfuge - 01 No Capacity : 30 kg/day MOC: PP 111 (xxii) MBBR Tank x2 Nos, Capacity : 5KL EachSize of each Tank : 1.4mx1.2mx3m+0.3FBMS with FRP Inside and Epoxy Paint Outside(xxiii) Secondary Tube Settler, Capacity : 6.3KL Size : 2.1mx1.2mx2.5m + cone+0.4m FBMS with FRP Inside and Epoxy Paint Outside(xxiv) Intermediate Tank- 01 No, Capacity : 10KL MOC : LLDPE (Readymade Tank)(XXV) Aeration TankMS FRP Module Size: 35 KL, MOC : MSFRP(xxvi) Secondary ClarifierMS FRP Module Size : 21 KL, MOC : MSFRP(xxvii) DO Meter- 01 No. Range: 0-20PPM, Type: Optocal, No Maintenance Make : Aquadex/AavolateNOTE : (1). The bidder shall submit a comprehensive proposal (plan of action) for execution of STP Capacity 100KLD, package type including ancillary civil works such as RCC UG collection Sump capacity 40KL capacity, RCC UG Treated water Sump capacity 30KL, Blower shed 4mx4mx3.5m height and intermediate Raw Sewage Sump cum pump house and all other connected items of work for persual and approval by the Accepting officer before commencement of STP work. The quotated rate shall be deemed to be inclusive of all civil works including earth work required etc, complete in all respect. 112 Supply, installation, commissioning and testing of non clog vertical submersible pump of capacity 1 hp with chrome steel impeller and cutter non clog to pass 40 mm size particles incl supply with guide rail and lifting chain(two working + one standby) to transfer raw sewage water from RCC sewage collection sump to bar screen chamber , having Discharge 50 LPM at a head of 25 metre suitable for delivery pipe , 415V (+ 5% & +10%) & frequency 50Hz. (1HP) including suitable size soft starter efficiency level-2 complete all as specified and directed. Material of Construction: Pump and Motor body: cast iron ,impeller:cast iron(a) Dry run protection.(b) 1 Nos of pressure guage 2 dia with valve tee and fittings.(c) Alarm indication with signal in the event of pump failure etc.(d) Arrangement of pressure switch with all connected accessories should be provided for protection of pumpsets.(e) Provision of GI/MS suction pipe of suitable size from clear water sump to pumpsets.(f) Delivery pipe of suitable size GI pipe heavy grade from pump set to existing delivery pipe flanged type complete with all fitting suitable for flanged pipe and necessary nut, bolts, washers and rubber gasket etc including fixing of butterfly valves and non return valve all as required. 113 M&L for construction of valve pitof size 0.6 x 0.6 x 0.6 m (internal diamention)one brickthick wall including MS sheet covermade of MS sheet 3 mm thickand 50 x 50 x 6 mm thick MS angle iron frame and locking arrangement and painting with two coatsof synthetic enamel paint over a coat of red oxide primer after preparation of surfaces complete all as specified and directed. 114 SOLAR POWER GENERATION SYSTEMDesign, procure, erect install, test and commission including connecting to local utility grid; Grid connected solar photovoitaic plant of 10 KWpcapacity (roof top)including solar photovoitaic Module, DC cabling, Module Mounting Structures, Combining Boxes, Lightning Protection of SPV modules and other accessories, string inverter, consisting of following main components: -Poly Crystaline Silicon Solar Photovolaic minimum of 335 Wp, not less than 10 KWp capacity, having efficiency 16.28% min under standard conditions, form fill factor more than 0.74, plant performance ratio > 75% , made of high transmitivity glass front surface and it shall give high encapsulation gain ( transmittance above 90% and bending less than 0.3%). The electrical parameters of SPV modules under standard test condition of irradiance 1000 W/sqm2, AM 1.5 Spectrum and temp 25 degree Celsius shall be as underMax Peak Power Pmax > 335 W Voltage at Max Power :>37.9V Current at Pmax: >8.85 AShort Circuit Current : > 9.41 AOpenCircuitVoltage: >46.27 VModule Efficiency: > 16.28 % . (a) Rated output of the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed.(b) It shall perform satisfactority in RH 85% with temperature up to +85 degree C and should withstand wind of 150 kmph on the surface of panel. Item Contined as Ser No. 17.82 to 17.86 115 (c) PVmodules shall be warrented for their output peak watt capacity, and it shall not fall of its initial value below 90% in first 10 year end and 80% after the end of 25 years. (d) Each module shall have RFID tag encapsulated with solar cell bearing following details: Name of manufacture of SPV Module, Name of Manufacturer of solar cell and module)country of Origin ( both cell and module) Peak wattage, Im, Vm and fill factor of the module IV curve of module. (e) The temperature coefficient of the module shall not be more than 0.50% degree celcius.(f) PV modules must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID. (g) It shall also be in confirmity to latest minimum technical specification issued by MNRE from time to time. Modules should be of 48 cell configuration and should be ofMNRE approved companies/agencies in category/ rating SA-1A(h) Provision of earting and earth strip/ cable etc for earth of solar Pvmodule/ array etc as per latest IS/MNRE norms to be provided and cost of the same is deemed to be included in the item and no extra amount will be paid to the contractor on this account. (j) Both cell and SPV modules shall be made in India and must conform to DSR norms of MNRE(k) The minimum net annual generation shall be 1500 units per kilowatt. 116 (l)DC Cables & AC Cables: Suitable size of XLPE insulated tinned copper cable of solar grade, 1100 volt and UV resistant for outdoor installations confirming to IEC 60227/15694 & 60502/ is 1554 (Pt& I&II) of minium size 6 sq.mm All cables and connectors for use of installation shall be of solar grade which can withstand harsh environmental conditions including high temperature, UV radiations, rain, dirt,burial and attack by moss and microbes for 25 years as voltage as per latest IEC/IS. All the cables/wires shall be provided with UV resistant printed ferrules for DC side .The size of the cable shall be such that average voltage drop at full power from PV module to inverter shall be less than 1.5%. The AC cables along with AC DB with necessary arrangement to Connect with the existing power supply to be done. The size of XLPE LT cable To be got approved by Engineer in charge. Suitable electronic smart meter To be fixed to measure generation of electricity. Cable batch no,drum no, IS code and size and make shall be metioned on every one meter or as per OEM practice .The wiring of the module interconnection shall be in suitable size UPVC/HDPE pipe. The cost of interconnecting DC copper cable, and earth work for trenches suitable to accommodate solar grade cables from SPV module upto inverters are included in the item. 117 (m)Module Mounting Structure: Design, procure, fixing, support structure made of hot dipped galvanisized iron with min 85 micron thickness including necessary PCC foundation and associated work and fixing mounting arrangement suitable for SPV modules so as it can withstand wind speed of 150km per hour. The array mounted structure has to be so designed that it occupies minimum space without sacrificing the output of SPV panels, Nuts, bolts,mounting structure including module mounting structure shall have to be adequately protected from atmosphere and weather prevailing in the area. All the modules fixing fastners shall be of stainless steel of grade SS316.The module mounting structure to be fixed tilt to optimise the maximum generation in a year. MMS design shall be supported with stadpro report and submitted for the approval of the acepting officer. Cost of all equipments, copper strip up to earth test point and copper earthing etc are included in this item. The cost of sufficient earthing for lightning protection is included in this item and no extra payment will be made to the contractor on this account. 118 (n)String Inverter: Procure, fixing, testing and commissioning of 10 KW , 50+3 Hz (min) 3 phase 460 volt, THD< 3%, at nominal power inverter suitable to convert DC power of solar PV module/arry/ to AC for further feeding to grid confirming to IEC 61683 for efficiency, IEC 62109 or equivalent for safety and IEC 62093 for reliability. The input DC technical specification of 10 KW inverter are as under: Input (DC) DC V oltage Range: 575-850 VMax DC Voltage:1000 VNominal Power : 10 kW Max output power : 10 kW Nominal AC current : as per standards Nominal output voltage: 460V Output Frequency : 50/60 Hz Harmonic Distortion current : < 3%Efficiency : 98.3%Standby operation consumption (feed in) : < 20 W 119 Operating temperature up to 85 degree centigrade . The inverter shall have minimum IP 65 protection, ground fault monitoring, gridmonitoring , protection against anti-islanding, DC reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and temperature . The inverter shall adjust voltage and frequency levels to suit the grid . The inverter shall be selfcommulated with Pulse Width Modulation (PWM) technology and shall be capable of synchronise maximum with in one min. Maximum Power Point Tracker(MPPT) confirming to IEC 62093 shall be integrated in the inverter to maximum the energy drawn from the PV array. The inverter shall be suitable nos of protected inputs (as per design) and outgoing shall be protected by Surge protections (MOVs) .The inverter shall be provided with protection class I (IEC 62103) .The inverter should have MODBUS, PROFIBUS, ETHERNET comn ports .The inverter shall include appropriate self protection and self diagnostic feature to protect itself and the PV array from the damage in the event of the inverter componant failure or from parameters beyond the inverters safe operating due to internal and/or external causes. Inverter shall have protection arrangement against ground leakage faults, over voltage, ( SPD) & over current. Inverter should interfaces with Ethernet, RS485, irradation and temperature sensor, Auxilary equipment and power supply, external stop signal. Should have residual monitoring system. 120 COMPREHENSIVE MAINTENANCE AND OPERATION OF SEWAGE TREATMENT PLANT (STP) AND LIFT (PHASE-III) 121 Supply and Dosing or filling of Sodium hypochloride solution (Hypo Solution) with 6% concentrate for chlorination in water treatment at STP of capacity 100 KLD as per parameters as per OEM recommendation complete all as specified and as directed. 122 Supply only of gear oil for comprehensive maintenance of Air blower complete all as specified and as directed. 123 Supply only of grease for comprehensive maintenance of equipments/ machines complete all as specified and as directed. 124 Annual Testing of lift by lift inspector of the State of Assam (once in a Year) of any type of lift and submit the test certificate to the department shall be done by contractor 125 Supply only Control Fuses (Glass Type 2A) electronic components complete all as specified and as directed. 126 Supply only Push Buttons of any type complete all as specified and as directed. 127 Supply only Rollers of any type complete all as specified and as directed. 128 Supply only Guide Shoes any type complete all as specified and as directed. 129 Supply only ARD Battery 7AH complete all as specified and as directed. 130 M & L for any welding machine work lathe work etc complete all as specified and directed. 131 MAINTENANCE AND OPERATION OF SEWAGE TREATMENT PLANT (STP) 132 Outsourcing services for manning and operation of sewage treatment plant (STP) of capacity 100 KLD by deploying 01 pump operator and 01 helper (01 operator + 01 helper), 03 shifts of 08 Hrs per shifts per day for 11 months at NAA comprising of following characteristics of inlet raw sewage / out let treated sewage equipments/ machines and pump sets including testing and operation of valves, operating sewage submersible / centrifugal pump of any number & any capacity and allied work, including Sundays/ holidays for operation of system as and when required and also carry out minor repairs / servicing/ rectification of faults as and when required to all machines/ equipments and valves to ensure 100% serviceability and maintain the ppm level both inlet raw sewage and out let treated sewage of plants and removing scaling materials, mud materials grass/ surface dressing from surrounding area including disposal of dry sludge out of MoD land on monthly basis complete all as specified and directedShift details -1 STP (100 KLD) x 3 shifts (1X OPERATOR AND 1X HELPER) = 3 SHIFTS Item Continued as 18.13 133 NOTE:-(a) Record daily log sheet shall be maintain in log book by the operator and should approved by the Engineer-in-Charge.(b) The operator shall be responsible for checking of maintaining the water parameters like BOD <10mg/ltr, COD < 30mg/ltr, PH 6.5-8.5, Faecal Coliform Nil in MPN/100ml, required chlorine 0.5, TSS <10mg/ltr, Nitrogen, N 5mg/Ltr, Oil grease < 10gm/ltr.(c) Dally cleaning of floor area and maintain a good and hygienic sanitation around the installation, minor repairs of sewage machinery /instruments at sewage pump house area including arrest cutting surrounding sewage pump house.(d) Stationary items such as registers, log books etc should be provided by the contractor.(e) Non providing to operator in day by the contractor shall invite penalty of Double the minimum fair wages per day from his due amount.(f) Suitable relieving staff shall be deployed by the contractor.(g) Tools open end & ring Spanner set, Hammer and other tools as required for maintenance of plant and tolls required for keeping surrounding area and installation in presentable shall be provided by contactor(h) The quoted rate are for STP technician deployed by contractor. Comprehensive maint of STP during defect liability period of 2 years shall be carried out by contractor without any additional cost to the department.(j) Contractor shall ensure and comply with minimum wages and other statutary charges all as applicable as per Govt Orders. 134 All as per Srl Item No. 18.12 & 18.13 here-in-above but for next eleven months from the next day after completion of 11 months. 135 All as per Srl Item No. 18.12 & 18.13 here-in-above but for next two months from the next day after completion of 22 months. 136 All as per Srl Item No. 18.12 & 18.13 here-in-above but for next eleven months from the next day after completion of 24 months. 137 All as per Srl Item No. 18.12 & 18.13 here-in-above but for next eleven months from the next day after completion of 35 months. 138 All as per Srl Item No. 18.12 & 18.13 here-in-above but for next eleven months from the next day after completion of 46 months. 139 All as per Srl Item No. 18.12 & 18.13 here-in-above but for next three months from the next day after completion of 57 months. 140 NOTE FOR SRL ITEM Nos. 18.16 to 18.19 :-(a) All minor parts like nut, bolts lubricant oil etc shall be deemed included in this quoted rate. (b) All necessary T&P required on site shall be provided by contractor without any extra cost.(c) Major parts other than above shall be supplied by the department as and when required, however fixing charges of same be included above quoted rate(d) Comprehensive maintenance for 03 years after Defect Liability Period shall be carried out by contractor only. The quoted rated is deemed to be inclusive of comprehensive maintenance. 141 MAINTENANCE AND OPERATION OF LIFT 142 Comprehensive maintenance of 11 Nos. Lifts, 8 passenger (11 x 8 passenger lift) and 07 Nos. LIft, 13 passenger (7 x 13 passenger lift) electrically operated Lifts of any type and make to serve any number of floors by providing services of Lift Technician (Skilled) [ITI qualified with sufficient experience in day to day maintenance and emergency rescue operation) for Bldg ( 1x Offr’s, 2x JCOs, 2x ORs) in required Shift on all the days for 11 months including Sunday & Holidays including taking care of from any pilferage, theft or damage etc to ensure smooth and trouble free operation of Lifts to the entire satisfaction of users/ department, complete all as specified and as directed.Shift details:-(a) 04 lift technicians on all days for day shift and 01 Lift Technician for night shift.NOTE:-(a) The Lift shall be operated daily in required Shifts as directed by the Engineer-in-Charge.(b) The quoted rate only include for Lift technician deployed by contractor. Comprehensive maint of all lifts shall be carried out by contractor without any additional cost to the department during defect liability period of 02 years.(c) Comprehensive maintenance of Lifts shall be done by OEM only.(d) Contractor shall ensure and comply with minimum wages and other statutary charges all as applicable as per Govt Orders. 143 All as per Srl Item No. 18.22 here-in-above but for next eleven months from the next day after completion of 11 months. 144 All as per Srl Item No. 18.22here-in-above but for next two months from the next day after completion of 22 months. 145 All as per Srl Item No. 18.22here-in-above but for next eleven months from the next day after completion of 24 months. 146 All as per Srl Item No. 18.22here-in-above but for next eleven months from the next day after completion of 35 months. 147 All as per Srl Item No. 18.22here-in-above but for next eleven months from the next day after completion of 46 months. 148 All as per Srl Item No.18.22here-in-above but for next three months from the next day after completion of 57 months. 149 NOTE FOR SRL ITEM Nos. 18.25 to 18.28 :-(a) All minor parts like nut, bolts, grease, cotton waste, lubricant oil etc. shall be deemed included in this quoted rate.(b) All necessary T&P required on site shall be provided by contractor without any extra cost.(c) Major parts other than above as recommended by OEM shall be supplied by the department as and when required, however fixing charges of same be include in above quoted rate.(d) Comprehensive maintenance shall be done OEM only.(e) Comprehensive maintenance for 03 years after Defect Liability Period shall be carried out by contractor only. The quoted rated is deemed to be inclusive of comprehensive maintenance. 150 NOTE FOR SRL ITEM No. 18.11 to 18.29The bidders shall ensure that the quoted amount for M & O is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.01 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment.