| Sl. No. | Item Description |
| 1 | UPS Tapa Khurd |
| 2 | Civil Work |
| 3 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 4 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-chargeIn cement mortar |
| 5 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead Of area beyond 3 sq. metres |
| 6 | Dismantling tile work in floors and roofs laid in cement mortar includingstacking material within 50 metres leadFor thickness of tiles 10 mm to 25 mm |
| 7 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead |
| 8 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transportincluding loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. |
| 9 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 10 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.All kinds of soil |
| 11 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 12 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: |
| 13 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. |
| 15 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. |
| 17 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinthlevel up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources). |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. |
| 19 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 20 | Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Mild steel and Medium Tensile steel bars |
| 21 | Providing and fixing factory made uPVC white color sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chamberedframe with in-built roller track and sash extruded profiles duly reinforcedwith 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to Upvc profile), appropriate dimension of uPVC extruded glazing beads anduPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylonrollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mmsize for fixing frame to finished wall and necessary stainless steel screwsetc. Profile of frame & sash shall be mitred cut and fusion welded at allcorners, including drilling of holes for fixing hardware\"s and drainage of |
| 22 | Providing and fixing 12 mm thick frameless toughened glass door shutterof approved brand and manufacture, including providing and fixing top &bottom pivot & double acting hydraulic floor spring type fixing arrangementand making necessary holes etc. for fixing required door fittings, allcomplete as per direction of Engineer-in-charge (Door handle, lock andstopper etc.to be paid separately). |
| 23 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or dash fastener shall be paid for separately)Sal wood |
| 24 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately)Second Class teak wood35mm thick shutters |
| 25 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0 mm thick |
| 26 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :300x10 mm |
| 27 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 28 | 12 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) |
| 29 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) |
| 30 | Distempering with oil bound washable distemper of approved brandand manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 31 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. |
| 32 | Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or / and residual bitumen applied hot at 1.45, 1.20 and 1.70 kg per square metre of area respectively, second and fourth courses of roofing felt type 2 grade I (fibre base self finished bitumen felt) six and final courses of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic decimeter per sqm including preparation of surface, excluding grading, compete. |
| 33 | Supplying and applying bituminous solution primer on roof and / or wall surface at 0.24 litre per sqm. |
| 34 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under: Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N.Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane 3 mm thick |
| 35 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75mm deep chase. |
| 36 | Providing and laying integral cement based water proofing treatmentincluding preparation of surface as required for treatment of roofs,balconies, terraces etc consisting of following operations: Applying a slurry coat of neat cement using 2.75 kg/sqm ofcement admixed with water proofing compound conformingto IS. 2645 and approved by Engineer-in-charge over the RCCslab including adjoining walls upto 300 mm height includingcleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm |
| 37 | Steel work welded in built-up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 38 | SUPPLYING, INSTALLATION, TESTING ANDCOMMISSIONING OF GRID INTERACTIVE ROOF TOP SOLAR PHOTO VOLTAIC POWER GENERATION SYSTEM INCLUDING SPACE FRAME (CPWD 6.7.1) 54480*0.735*109/107=40791.30 |
| 39 | ProvidingofRainwaterharvestingetc.allcomplete (as per attatch estimate). |
| 40 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 41 | Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with machine cut edges of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). Red sand stone - 30mm thick gang saw cut stone |
| 42 | Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand 4 graded stone aggregate 20 mm nominal size) of size 300×230x300 mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). |
| 43 | Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gram), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge |
| 44 | Providing and fixing 18 mm thick Granite (gang saw cut), mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/ Ruby red Area of slab over 0.50 sqm |
| 45 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \" |
| 46 | Kota stone slab flooring over 20 mm (average) thick base laid over andjointed with grey cement slurry mixed with pigment to match the shadeof the slab, including rubbing and polishing complete with base of cementmortar 1 : 4 (1 cement : 4 coarse sand) : |
| 47 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineerin-Charge. External work. 100 mm nominal inner dia pipes |
| 48 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 49 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 50 | Supply of fixing ACP WITHLED light Letters for Nagar Nigam Logo with text ` as per drawing |
| 51 | Supply and fixingof C02 type fire extinguisher4.5 kg. capacity each (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completionof work. |
| 52 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 53 | Smart Class, CCTV & Furnture Work |
| 54 | Interactive Display Board 65 Inches Diagonal with custom casing with Green Board SITC of 65\" Multipurpose Interactive digital board , native resolution -3,840 x 2,160 (UHD),Panel Technology- IPS,Brightness(Typ., cd/m²)-360 nits,Life Time (Typ.)-30000Hrs,Built in 24W (12W + 12W) speakers, ,Input HDMIX3,RGB/Audio,RJ45 ,optical output/audio out, Embedded Writing Annotation Software reuired Intuitive UX/UI with built-in annotation SW with Latest Features like Palm erasing, Finger and styllus writing , touch type - IR/ In glass/ PCAP (10 Multi touch or more),Built in Wi-Fi with dual antenna, Screen Sharing provision of 6 Devices at the same time from Android, Mac, Windows, IOS Devices,Built in Web browser and PC Less Operations to work on PDF, Excel, Word and PPT Files,2 x Pens with magnet, OPS slot installation and testing of Learning Management Software Applications like Diksha, E- Pathshaala etc. Will be approved by Engineer-in-charge). |
| 55 | Two Seater Desk Bech for Studying on Smart Class and Language Lab (20 Sets @ Rs. 6500 per Set) Will be approved by Engineer-in-charge). |
| 56 | Books for library |
| 57 | Furniture for library corner (01 Unit of 12 Seater Desk with 24 Chairs ) Will be approved by Engineer-in-charge). |
| 58 | Table & Chairs for instructer/teacher (1 set) Will be approved by Engineer-in-charge). |
| 59 | 20 Set of All In one desktop computer set Processor Speed 2 GHz Base Speed or higher, Motherboard Intel J5040 Quad Core or better/AMD Athlon 3050U or better/other ; Memory 4 GB SDR or better, memory tech DDR4 or better ; HDD 1 TB ESATA or better; Monitor 18.5 inch Diagonal dispaly size or better ; Keyboard Standard Keyboard wired/wireless ; Mouse USB Optical Scroll Mouse ; Ethernet RJ45 Ethernet or better 2X USB 3.0 ports or better, 1 HDMI port or better, t; Operating System DOS/Windows 10 Home; Graphics Integrated HD Graphics ; Warranty :Standard On-site manufacturer Warranty @ Rs 39,000 per Desktop computer |
| 60 | 1 Set of All in one Print, Scan, Copy, Fax Print Speed (A4): 23 pages per minute Monthly print volume: 500 - 2 000 pages (Recommended) Print Resolution: 1200 x 1 200dpi (equivalent) FPOT (A4): 6.0s Vari- Angle Operation Panel (9.2 cm monochrome touch panel), One-Touch Solution Keys, Touch Screen LCD, 35-sheet Auto Document Feeder |
| 61 | Green Board/White Board for Computer Room. |
| 62 | Table & Chairs for instructer/teacher (1 set) Will be approved by Engineer-in-charge). |
| 63 | Almirah with 12 set of Locker Will be approved by Engineer-in-charge). |
| 64 | Installation of Inverter & Battery Combo (1 No. Cruze + 4 KVA Pure Sine Wave Inverter, 3 No. RC 18000 150 Ah Tall Tubular Battery) Will be approved by Engineer-in-charge). |
| 65 | Furniture (Desk-Bench) for Class 1 to 5. (70 sets of Desk-bench for 220 Students) @ Rs. 6500 per set |
| 66 | 150 Liters/hour L Water Cooler (Maximum Energy Consumption (Watt) 1550 Watt for 150 ltr/hrcooling cap.) Will be approved by Engineer-in-charge). |
| 67 | Fully automatic with auto cut off RO Potable Water Purification System (Filtration Capacity in liter/hour 50, Manufacturers Quality System Certifications ISO 9001:2015) Will be approved by Engineer-in-charge). |
| 68 | Connection Charges for High speed Internet |
| 69 | Two Set of high frequency Modem Wi-Fi Speed Up to 867 Mbps/5 GHz + 300 Mbps/2.4 GHz, 5 Gigabit Ports, 4 External Antennas, MU-MIMO, Dual Band, WiFi Coverage with Access Point Mode,Wireless Router with LAN Cable connection Will be approved by Engineer-in-charge). |
| 70 | Two Set of high frequency Modem Wi-Fi Speed Up to 867 Mbps/5 GHz + 300 Mbps/2.4 GHz, 5 Gigabit Ports, 4 External Antennas, MU-MIMO, Dual Band, WiFi Coverage with Access Point Mode,Wireless Router with LAN Cable connection Will be approved by Engineer-in-charge). |
| 71 | Grand Total (Less 1% Labour cess + 18% GST)= (D) |
| 72 | External Development Work |
| 73 | Construction and Installation of Open Gym with BALA concept Will be approved by Engineer-in-charge). |
| 74 | Development of horticulture and land development/landsceping Will be approved by Engineer-in-charge). |
| 75 | Repairing, Refurbishing and Maintaince of Exesting class rooms as per requirement.Includes Painting+Replacement of Door & Window+Roof\"s Water Proofing+Floor Tiling+ 30% of Plaster + Maintenance and Re-furbishing of existing toilet with Repairing/Installation of Pipe Line, Plaster & Tiles, Water Supply System and Sanitary fitting as required) + Modification of existing kitchen with tiling, flooring, plotform repairing etc. + Maintenance & Modification of Entrance Gate ( Maximumof up to 8 Class Rooms, 1 Principal room, 1 Kitchen, 2 Toilets Unit & 1 Entrance Gate) |
| 76 | Construction of CWSN (Child with Special Need) toilet |
| 77 | Construction of Multiple Hand Washing System |
| 78 | Extension of height of existing boundary wall with the help of barbed wire (upto 300 meter) |
| 79 | Construction of Securit Guard\"s Room |
| 80 | Playing Equipments |
| 81 | Supply and fixing of 3 Seater Arc Rubber Belt Swing size 13x3.50x8 feet as per attach photograph. |
| 82 | Supply and fixing of 2 Seater See Saw size 6x2.29 feet as per attach photograph. |
| 83 | Supplying, installation, testing and commissioning of IP based CCTV system for Building security comparising of PTZ/ fixed camera, cabling, digital recording, display system and hardware software for indoor only |
| 84 | Electric Work |
| 85 | Water and Sanitary Installation work |
| 86 | 5 Year Operation and Maintainancel |
| 87 | UPS Multi Storey Sailai |
| 88 | Civil Work |
| 89 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 90 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-chargeIn cement mortar |
| 91 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead Of area beyond 3 sq. metres |
| 92 | Dismantling tile work in floors and roofs laid in cement mortar includingstacking material within 50 metres leadFor thickness of tiles 10 mm to 25 mm |
| 93 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead |
| 94 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transportincluding loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. |
| 95 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 96 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.All kinds of soil |
| 97 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 98 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: |
| 99 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 100 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. |
| 101 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 102 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. |
| 103 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinthlevel up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources). |
| 104 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. |
| 105 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 106 | Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Mild steel and Medium Tensile steel bars |
| 107 | Providing and fixing factory made uPVC white color sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chamberedframe with in-built roller track and sash extruded profiles duly reinforcedwith 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to Upvc profile), appropriate dimension of uPVC extruded glazing beads anduPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylonrollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mmsize for fixing frame to finished wall and necessary stainless steel screwsetc. Profile of frame & sash shall be mitred cut and fusion welded at allcorners, including drilling of holes for fixing hardware\"s and drainage of |
| 108 | Providing and fixing 12 mm thick frameless toughened glass door shutterof approved brand and manufacture, including providing and fixing top &bottom pivot & double acting hydraulic floor spring type fixing arrangementand making necessary holes etc. for fixing required door fittings, allcomplete as per direction of Engineer-in-charge (Door handle, lock andstopper etc.to be paid separately). |
| 109 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or dash fastener shall be paid for separately)Sal wood |
| 110 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately)Second Class teak wood35mm thick shutters |
| 111 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0 mm thick |
| 112 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :300x10 mm |
| 113 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 114 | 12 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) |
| 115 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) |
| 116 | Distempering with oil bound washable distemper of approved brandand manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 117 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. |
| 118 | Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or / and residual bitumen applied hot at 1.45, 1.20 and 1.70 kg per square metre of area respectively, second and fourth courses of roofing felt type 2 grade I (fibre base self finished bitumen felt) six and final courses of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic decimeter per sqm including preparation of surface, excluding grading, compete. |
| 119 | Supplying and applying bituminous solution primer on roof and / or wall surface at 0.24 litre per sqm. |
| 120 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under: Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N.Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane 3 mm thick |
| 121 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75mm deep chase. |
| 122 | Providing and laying integral cement based water proofing treatmentincluding preparation of surface as required for treatment of roofs,balconies, terraces etc consisting of following operations: Applying a slurry coat of neat cement using 2.75 kg/sqm ofcement admixed with water proofing compound conformingto IS. 2645 and approved by Engineer-in-charge over the RCCslab including adjoining walls upto 300 mm height includingcleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm |
| 123 | Steel work welded in built-up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 124 | SUPPLYING, INSTALLATION, TESTING ANDCOMMISSIONING OF GRID INTERACTIVE ROOF TOP SOLAR PHOTO VOLTAIC POWER GENERATION SYSTEM INCLUDING SPACE FRAME (CPWD 6.7.1) 54480*0.735*109/107=40791.30 |
| 125 | ProvidingofRainwaterharvestingetc.allcomplete (as per attatch estimate). |
| 126 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 127 | Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with machine cut edges of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). Red sand stone - 30mm thick gang saw cut stone |
| 128 | Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand 4 graded stone aggregate 20 mm nominal size) of size 300×230x300 mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). |
| 129 | Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gram), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge |
| 130 | Providing and fixing 18 mm thick Granite (gang saw cut), mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/ Ruby red Area of slab over 0.50 sqm |
| 131 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \" |
| 132 | Kota stone slab flooring over 20 mm (average) thick base laid over andjointed with grey cement slurry mixed with pigment to match the shadeof the slab, including rubbing and polishing complete with base of cementmortar 1 : 4 (1 cement : 4 coarse sand) : |
| 133 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineerin-Charge. External work. 100 mm nominal inner dia pipes |
| 134 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 135 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 136 | Supply of fixing ACP WITHLED light Letters for Nagar Nigam Logo with text ` as per drawing |
| 137 | Supply and fixingof C02 type fire extinguisher4.5 kg. capacity each (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completionof work. |
| 138 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 139 | Smart Class, CCTV & Furnture Work |
| 140 | Interactive Display Board 65 Inches Diagonal with custom casing with Green Board SITC of 65\" Multipurpose Interactive digital board , native resolution -3,840 x 2,160 (UHD),Panel Technology- IPS,Brightness(Typ., cd/m²)-360 nits,Life Time (Typ.)-30000Hrs,Built in 24W (12W + 12W) speakers, ,Input HDMIX3,RGB/Audio,RJ45 ,optical output/audio out, Embedded Writing Annotation Software reuired Intuitive UX/UI with built-in annotation SW with Latest Features like Palm erasing, Finger and styllus writing , touch type - IR/ In glass/ PCAP (10 Multi touch or more),Built in Wi-Fi with dual antenna, Screen Sharing provision of 6 Devices at the same time from Android, Mac, Windows, IOS Devices,Built in Web browser and PC Less Operations to work on PDF, Excel, Word and PPT Files,2 x Pens with magnet, OPS slot installation and testing of Learning Management Software Applications like Diksha, E- Pathshaala etc. |
| 141 | Registering from 40 student @ Rs. 6500 per student and Connectivity to ext. audio devices (VCD player/PC/VHS player etc). |
| 142 | Two Seater Desk Bech for Studying on Smart Class and Language Lab (20 Sets @ Rs. 6500 per Set) |
| 143 | Books for library |
| 144 | Furniture for library corner (01 Unit of 12 Seater Desk with 24 Chairs ) |
| 145 | Table & Chairs for instructer/teacher (1 set) |
| 146 | 20 Set of All In one desktop computer set Processor Speed 2 GHz Base Speed or higher, Motherboard Intel J5040 Quad Core or better/AMD Athlon 3050U or better/other ; Memory 4 GB SDR or better, memory tech DDR4 or better ; HDD 1 TB ESATA or better; Monitor 18.5 inch Diagonal dispaly size or better ; Keyboard Standard Keyboard wired/wireless ; Mouse USB Optical Scroll Mouse ; Ethernet RJ45 Ethernet or better 2X USB 3.0 ports or better, 1 HDMI port or better, t; Operating System DOS/Windows 10 Home; Graphics Integrated HD Graphics ; Warranty :Standard On-site manufacturer Warranty @ Rs 39,000 per Desktop computer |
| 147 | 1 Set of All in one Print, Scan, Copy, Fax Print Speed (A4): 23 pages per minute Monthly print volume: 500 - 2 000 pages (Recommended) Print Resolution: 1200 x 1 200dpi (equivalent) FPOT (A4): 6.0s Vari- Angle Operation Panel (9.2 cm monochrome touch panel), One-Touch Solution Keys, Touch Screen LCD, 35-sheet Auto Document Feeder |
| 148 | Furniture for Computer Room (20 Computer table & 40 chairs) |
| 149 | Green Board/White Board for Computer Room. |
| 150 | Table & Chairs for instructer/teacher (1 set) |
| 151 | Table & Chairs for staff room (For sitting arrangement of 20 Teachers) |
| 152 | Almirah with 12 set of Locker |
| 153 | Installation of 2 set of Electric Incinerator attached with girl\"s toilet |
| 154 | Installation of Inverter & Battery Combo (1 No. Cruze + 4 KVA Pure Sine Wave Inverter, 3 No. RC 18000 150 Ah Tall Tubular Battery) |
| 155 | Furniture (Desk-Bench) for Class 1 to 5. (70 sets of Desk-bench for 220 Students) @ Rs. 7500 per set |
| 156 | 150 Liters/hour L Water Cooler (Maximum Energy Consumption (Watt) 1550 Watt for 150 ltr/hrcooling cap.) |
| 157 | Fully automatic with auto cut off RO Potable Water Purification System (Filtration Capacity in liter/hour 50, Manufacturers Quality System Certifications ISO 9001:2015) |
| 158 | Connection Charges for High speed Internet |
| 159 | Two Set of high frequency Modem Wi-Fi Speed Up to 867 Mbps/5 GHz + 300 Mbps/2.4 GHz, 5 Gigabit Ports, 4 External Antennas, MU-MIMO, Dual Band, WiFi Coverage with Access Point Mode,Wireless Router with LAN Cable connection |
| 160 | Grand Total (Less 1% Labour cess + 18% GST)= (D) |
| 161 | External Development Work |
| 162 | Construction and Installation of Open Gym with BALA concept |
| 163 | Development of horticulture and land development/landsceping |
| 164 | Repairing, Refurbishing and Maintaince of Exesting class rooms as per requirement.Includes Painting+Replacement of Door & Window+Roof\"s Water Proofing+Floor Tiling+ 30% of Plaster + Maintenance and Re-furbishing of existing toilet with Repairing/Installation of Pipe Line, Plaster & Tiles, Water Supply System and Sanitary fitting as required) + Modification of existing kitchen with tiling, flooring, plotform repairing etc. + Maintenance & Modification of Entrance Gate ( Maximumof up to 8 Class Rooms, 1 Principal room, 1 Kitchen, 2 Toilets Unit & 1 Entrance Gate) |
| 165 | Construction of CWSN (Child with Special Need) toilet |
| 166 | Construction of Multiple Hand Washing System |
| 167 | Extension of height of existing boundary wall with the help of barbed wire (upto 300 meter) |
| 168 | Construction of Securit Guard\"s Room |
| 169 | Playing Equipments |
| 170 | Supply and fixing of Wheel Chair Swing size 14x8x10 feet as per attach photograph. |
| 171 | Supply and fixing of 3 Seater Arc Rubber Belt Swing size 13x3.50x8 feet as per attach photograph. |
| 172 | Supply and fixing of 2 Seater See Saw size 6x2.29 feet as per attach photograph. |
| 173 | Electric Work |
| 174 | Water and Sanitary Installation work |
| 175 | 5 Year Operation and Maintainancel |