| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:All kinds of soil : |
| 2 | Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 3 | Providing and laying in position specified grade of reinforced cement concrete includingcuring but excluding the cost of centering, shuttering, finishing and reinforcement. Allworks upto plinth level1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 4 | Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 5 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 6 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 7 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 8 | Reinforced cement concrete work in walls (any thickness) including attached pilasters,buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts andstruts upto floor five level including curing but excluding cost of centering shuttering,finishing and reinforcement 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering,finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 12 | Foundations, footings, bases of columns etc. for mass concrete |
| 13 | Suspended floors, roofs, landings, balconies and access platforms. |
| 14 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 15 | Columns, pillars, piers, abutments, posts and struts. |
| 16 | Edges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 17 | PProviding and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60mm thickness,including hinges jamb, lock jamb, bead and if required angle threshold ofmild steel angle of section 50x25mm, or base ties of 1.60mm pressed, mildsteel welded or rigidly fixed together by mechanical means, including M.Spressed butt hinges 2.5mm thick with mortar guards, lock strike-plate andshock absorbers as specified and applying a coat of approved steel primerafter pre-treatment of the surface as directed by Engineer-in-charge:Fixing with adjustable lugs with split end tail to each jamb |
| 18 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all completeFixed to steel windows by welding |
| 19 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 20 | 12mm cement plaster of mix 1 : 6 ( 1 cement : 6 fine sand) |
| 21 | 15mm Cement plaster on the rough side of single or half brick wall ofmix:1 : 6 ( 1 cement : 6 fine sand) |
| 22 | Providing and laying Vitrified tiles in floor with different sizes(thickness to be specified by the manufacturer), with water absorptionless than 0.08% and conforming to IS: 15622, of approved brand andmanufacturer, in all colours and shades, laid with cement based highpolymer modified quick set tile adhesive (water based) conforming to IS:15477, in average 6 mm thickness, including grouting of joints (Paymentfor grouting of joints to be made separately).Size of tile 600x600 mm |
| 23 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacturer), of approved make, in all colours, shadesexcept burgundy, bottle green, black of any size as approved by Engineer- in-Charge, inskirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointingin white cement mixed with pigment of matching shade complete. |
| 24 | Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size withnecessary screws, excluding panelling which will be paid for separately, allcomplete as per direction of Engineer-in-charge. (Note: -Butt hinges andnecessary screws shall be paid separately).Second kail wood |
| 25 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Plain particle board flat pressed, 3 layer or graded wood particle boardmedium density Grade I, IS : 3087 marked |
| 26 | Providing and fixing glazed shutters for doors, windows and clerestory windowsusing 4mm thick float glass panes including ISI marked M.S. pressed butthinges bright finished of required size with necessary screws.Second class Kail wood |
| 27 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze ofaverage width for aperture 1.4 mm in both directions with wire of dia. 0.63 mmfor doors, windows and clerestory windows with ISI marked M.S. pressed butthinges bright finished of required size with necessary screws as per direction ofEngineer-in-charge :Second class Kail wood 35mm thick |
| 28 | Providing and fixing ISI marked oxidized M.S. sliding door bolts with nuts andscrews etc. complete :250x16 mm |
| 29 | Providing and fixing aluminum tower bolts ISI marked anodized (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed torequired colour or shade with necessary screws etc. complete :200x10 mm |
| 30 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :150x10mm |
| 31 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 100x10mm |
| 32 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.100mm |
| 33 | Providing and fixing aluminum handles ISI marked anodized (anodic coatingnot less than grade AC 10 as per IS: 1868) transparent or dyed to requiredcolour and shade with necessary screws etc. complete. 125 mm |
| 34 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size |
| 35 | Distempering with oil bound washable distemper of approved brand andmanufacture to give an even shade on New work (two or more coats) overand including priming coat with water thinnable cement primer |
| 36 | Applying priming coat:With ready mixed pink or grey primer of approved brandand manufacture on wood work (hard and soft wood) |
| 37 | Finishing walls with acrylic smooth exterior paint of required shade onNew work (Two or more coats applied @ 1.67 liter/10sqm over andincluding priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 38 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 39 | Providing and fixing on wall face un-plasticized Rigid PVC rain waterpipes conforming to IS: 13592 Type A including jointing with seal ringconforming to IS: 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes 110 mm diametre |
| 40 | Providing and fixing electric point complete in all respect as per necessary as site (NSI) |
| 41 | Carriage of material by mechanical transport from source to the site of work including loading/unloading and stakcing complete. |
| 42 | Sandfor an av. 100 Kmsdisntace. |
| 43 | Bajreefor an av . 35Kms distance |
| 44 | Bricksfor an avg. lead of110kmsdistance. |