| 1 | M&L for preventive maintenance of fire alarm system complete Addressable type at 24 ED technical area having smoke, heat, multi detector, beam detector, Addressable module, manual call point, addressable electronic sounder cum strobe, short circuit isolator, electronic siren, PA system complete with monthly checkup of entire system and unlimited breakdown calls complete all as specified & directed.NOTE:-(i) Testing of fire alarm system as per relevant IS in the presence of the user and Engr-in-Charge is deemed to be included in the quoted rate. (ii) The spare parts required to be replaced will be measured and paid seperately.(iii) The unserviceability noticed of fire alarm system shall be attended with in 72 hours failing which a sum of Rs 1000/- per day shall be recovered from the contractor.(iv) The preventive maintenance of fire alarm system under this contract shall be done through rep of OEM only.(v) The contractor shall carry out routine checking of the complete fire alarm system and rectify the minor/major defect noticed during checking immediately. Cleaning of detector once in a month and making the maintenance register for above maintenance and one separate register to be maintained by the contractor. The register will be signed by Engr-in-Charge / JE (E/M) and user rep after rectifying the defect.(vi) Contractor shall rectify the defect between 0700 Hrs to 1500 Hrs. |
| 2 | Taking down old unserviceable Switch power supply (SMPC) of Control Panel as existing make Morley and supply and fixing Switch power supply (SMPC) input 100-240 V out put 24 V, 1.3 to 2 Amp, operating temperature -10 degree to + 50 degree C, closed housing with protection against mains AC, short circuit protection in-built filter against EMC interference complete all as specified & directed. |
| 3 | Taking down old unserviceable detector base and supply and fixing analogue Addressable detector base advanced protocol and smoothing filter to suppress false alarm maintain loop connectivity complete all as specified & directed. |
| 4 | Taking down old unserviceable Heat detector and Supply, Installation, testing and commissioning addressbale sensor type certified to EN 54 part 1, 58 degree addressable type microprocessor based, programable inteligent type, blue light optical thermal heat detector with detector base, advanced protocol and smoothing filter to suppress false alarm, rotary decade switches, in-built isolator, dual Integrated LED for 360 degree visibility, LPCB approved, environment friendly-meets WEEE & RoHS legislative requirements, operating voltage 15 to 32 Vdc complete including necessary connection complete all as specified & directed. |
| 5 | Supply, Installation, testing and commissioning in replacement addressable sensor type certified to EN 45 addressable type microprocessor based, programmable intelligent type, blue light optical smoke detector with detector base, advanced protocol and smoothing filter to suppress false alarm, rotary decade switches, in-built isolator, dual Integrated LED for 360 degree visibility, conforms to EN 54-7, LPCB approved, environment friendly-meets WEEE & RoHS legislative requirements, operating voltage 15 to 32 Vdc complete including necessary connection complete all as specified & directed. |
| 6 | Supply, Installation, testing and commissioning in replacement addressable intelligence having inbuilt microprocessor, memory and decision algorithm twin angle with both forward and backward light scattering mechanism cum thermal multicriteria detector (sensor) with heat and smoke combination confirms EN54-5 & FN 54-7 LPCB approved complete all as specified & directed. |
| 7 | S&F in replacement maintenance free battery of capacity 12 Volt 7 AH, VRLA AGM type including standard spade terminals connecting and testing at site complete with one year warranty including taking down old unserviceable battery complete all as specified & directed. |
| 8 | Taking down old unserviceable PCB of main Control panel of fire alarm and S&F of new PCB of existing make complete all as specified & directed. |
| 9 | S&F in replacement ONLINE UPS 1 KVA (1000 VA) 6 Volt pure sinewave without in-Built batteries,40-50 Min backup, inbuilt OVCD (over voltage Cut off Device) with surge protection, efficient micro controller based, advanced PFC technology, static bypass-improves reliability, over temperature indication and protection, generator compatible, boost function for low input over voltage protection Extended input voltage range of 135 to 300 volt UPS to battery backup mode including wall mounted stand for UPS suitable size complete all as specified & directed. Note: Old unserviceable UPS shall be deposited to be for claiming the payment. |
| 10 | M&L in replacement sub main wiring with two run of single core PVC FRLS IS-694 cable with multi stranded copper conductor of size 1.50 Sqmm and drawing through in PVC medium grade heavy duty conduit pipe on surface of wall with using 1.50 Sqmm PVC insulated unsheathed multi stranded copper conductor cable connected to earth and earth dolly in conduit including connecting to main board including PVC conduit heavy duty minimum 20 mm dia size complete all as specified & directed. NOTE : (i) One run of conduit with three run of copper cable in equal size shall be measured against one unit. |
| 11 | Taking down any type of detector and clean properly with help of air blower and after cleaning fixed in existing position complete all as specified & directed.Note : T&P (ladder, Air blower, etc) shall be arranged by the Contractor under his own cost and arrangement complete all as specified & directed. |
| 12 | Supply, Installation, testing and commissioning in replacement floor/surface mounting addressable microprocessor fire alarm control main control panel single loop with BS EN 54 and indicating panel sounder circuits complete with LCD Display and push button to acknowledge alarm, testing and reset suitable for operation 230 volts single phase 50 Hzs AC supply 24 V DC supply with suitable capacity charger maintenance free batteries and battery charger, compatable with detector for communication to detectors and2 x 16 character LCD, confirming to IS : 2189 and BSEN 54 of capacity from 99 detector and 99 module devices upto 200 detector single loop 6*4\" character 2 sounder circuits PTR requires network card and modules (per each loop) etc including making all connection and fixing accessories complete all as specified & directed. |
| 13 | Supply, install, testing and commissioning in replacement conventional electronic speaker cum hooter with range of 25-30 meter with output not less than 4 watt including necessary connection complete all as specified & directed. |
| 14 | Taking down old unserviceable siren and supply and fixing Fire Alarm Sounders / Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured with sound output variation of +5 DB 500 mtrs range complete all as specified & directed. |
| 15 | S&F in replacement addressable control unit for siren complete all as specified & directed. |
| 16 | S&F addressable type Manual Call point resettable type compatible with main fire alarm control board microprocessor based as per IS-2189complete all as specified and directesd. |
| 17 | Taking down old unserviceable cable and Supply and laying for XLPE insulated PVC innersheathed, armoured, LT control cableFRLS multistranded copper conductor, 1100 volts grade, cross-sectional area 2.50 Sqmm 4 core as per IS 7098 (Part I) 1988 complete all as specified & directed. |
| 18 | S&F in replacement AFO (Auto fire off) plastic fire extinguisher ball (orange colour) it can self active in the presence of fire, active within 3 to 5 seconds upon reaching the appropriate temprature and extenguish the fire, maintenance free for period 5 years, completely harmless to the human body, area cover 360 degree angle, area of about 70 to 80 sqft, it can be extinguish three classes of fire, solid, Liquid and electrical classes of fire, weight 1.50 Kg, 100% eco friendly, 100% bio-degradable along with fixing on wall accessories complete all as specified & directed. |
| 19 | S&F in replacement Fire extinguisher spray 50 ml aluminium body with stand, spray that works immediately on touch to keep small from growing dangerously out of control complete all as specified & directed. |
| 20 | S&F in replacement Eco fire ABC powder type 6 Kg fire extinguisher (red and black) effective for all type of fire with wall mount hook,ISI/ BIS marked, ISO & CE certified multipurpose use with 5 year warranty portable complete all as specified & directed. Make :-\"Eco Fire / AMEREX / Kidde\" |
| 21 | S&F in replacement Eco fire ABC powder type 9 Kg fire extinguisher (red and black) effective for all type of fire with wall mount hook,ISI/ BIS marked, ISO & CE certified multipurpose use with 5 year warranty portable complete all as specified & directed. Make :- \"Eco Fire / AMEREX / Kidde\" |
| 22 | Taking out old unserviceable XLPE LT cable any type any size complete all as specified and directed |
| 23 | Excavation in trenches not exc 1.5 M wide and not exc 1.5 M indepth for pipe line, etcgetting out in soft/ loose soil and levelling of bottom surface to required level complete all as specified & directed. |
| 24 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 CM complete all as specified & directed. |
| 25 | Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified & directed. |
| 26 | Supply, laying and spreading of dry (Ganga) sand, free from organic impurities for cushioningas in trenches 8cm depth below cable and 15cm above cable andpunned to 10cm depthcomplete all as specified & directed. Note :- Punned thickness shall be considered for measurement purpose. |
| 27 | M&L brick, sub class \"B\" bricks laid dry, flat, length equal to width of brick over sand cusioning in trenches for cable protection complete all as specified & directed. |
| 28 | Labour only for reuse of serviceable bricks obtained from taking down of cable complete all as specified & directed. |
| 29 | M&L for cutting /boringto plinth protection/ hard standing / road etc in suitable depth to across the GI pipe size upto 80 mm dia of bore for drawn through XLPE under ground cable forgivingmechanical protection to cable complete all as directed.(Note : Quoted rate shall be included the cost of required material for repairing to disturbed surface complete all as per existing site complete all as specified & directed.) |
| 30 | S&F in replacement galvainesd water tubing light grade 50 mm dia of borewith fix with pole/ surface of wall / laid in trench etc as required atsitecomplete all as specified & directed. |
| 31 | Supply, laid in trench /fixedin replacement with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area3.5 core x 35 Sqmm (earthed) complete all as specified & directed. |
| 32 | Supply, laid in trench /fixedin replacement with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area3.5 core x 50 Sqmm (earthed) complete all as specified & directed. |
| 33 | Taking down old foam of fire extinguisher and refilling of ABC powder type, CO2 fire extinguisher, foam type firein extinguisher cylinder complete all as specified & directed. (Note : Contractor shall be provide all safety equipment to the person which is refill the Cylinder) |
| 34 | S&F in repair MCCB 4 Pole 250 Amps, rated Ultimate Shortcircuit Breaking Capacity 25 KAIcu at 415 V (kA rms thermal & magnetic adjustable type, 415 volts with extended copper terminals including taking out existing unserviceable / burnt MCCB from site complete all as specified & directed. |
| 35 | S&F in repair MCCB 4 Pole 160 Amps, rated Ultimate Shortcircuit Breaking Capacity 25 KAIcu at 415 V (kA rms thermal & magnetic adjustable type, 415 volts with extended copper terminals including taking out existing unserviceable / burnt MCCB from site complete all as specified & directed. |
| 36 | Supply, install, testing and commissioning of Solar PV modules of minimum rating 315 W with Glare Retardent Poly Crystalline Module made up of Blue Silicon shall be certified as per IEC 61215-Edition -II, IEC 61646 and IEC 61730-1 & 2 complete incl taking out old unserviceable solar module all as specified . solar Modules should be in conformity of latest technical specification issued by MNRE andmust use a R F identification tag (RFID) complete all as specified & directed. |
| 37 | M&L for repair, testing and commissioning of Main distribution board Floor Mounted DC Panel, DC Bus, Auxiliary Buses for required load as per site requirement on DC side of inverter complete all as specified & directed. |
| 38 | M&L for repair, testing and commissioning of Main distribution board Floor Mounted AC Panel, AC Bus,Auxiliary Buses for required load as per site requirement on AC side of inverter complete all as specified and directed . |
| 39 | M&L for repair of array junction box of 1000 V DC capacity by checking shunt monitoring card and other control accessories,connections etc complete all as specified and directed |
| 40 | S&F in repair PV junction box ,IP-65 suitable for one incoming and one outgoing to make series connection of solar panels complete all as specified and directedof 1000 V DC capacity by checking shunt monitoring card and other control accessories,connections etc complete all as specified and directed. |
| 41 | Supply , laid and connectionin replacement of PVC sheathed DC cable 1100 volt confirming IS-694 ISI marked ,4 sqmm single suitable for solar panel connections incl jointer,cliping ,saddeles etc for fixing complete all as specified and directed. |
| 42 | M&L for repair,maintanance,servicing and callibration ofInverter/PCU, DCto AC (indoor type) ofcapacity 100 kW of make statcon throughspecialised agency or OEMby checkingthe functioning, control, motherboard, transformer, protection accessories like relay,fuse MCBs, contactor and rewiring complete in all respect to make serviceable by repair the parts or replacing the defective parts which are not repairable .complete testing on load shall be carried out for proper functioning of complete system .Note :-(i) Power Conditioning Units (PCU):PCUs shall be warranted for any manufacturing defect of bad workmanship for contract liability period from the date of completion ofthe work.(ii). During the period of Warranty the CONTRACTOR shall remain liable to replace any defective parts that become defective in the PCU,provided such defective parts are not repairable at site. After replacement the defective parts shall be returned to the CONTRACTOR.(iii) Bidder has advised to visit the site before quoting the rate . |
| 43 | M&L for testing and recommissioning of existing grid tie solar power plant of capacity 200 KVA,that consists of 634 Nos of solar panel of 315 watt capacity,ACDB and DCDB box ,Array junction box,two nos inverter (PCU) indoor type of 100 KW etc.Intregation,commisioning and balancing of all the component of solar plant through specialised agency in this field or OEM rep to became solar plant functional andprovide adequate output.The testing of complete solar system shall be carried out for 72 hours for proper functioning and adequate solar output in presence of user and Engr-in-Charge complete all as specified and diected |
| 44 | M&L for preventive maintenance of roof top Solar panel of 200 KVA capacity by removing the dust/dry leaves with clean water, wiping and checking the wire connection of solar panel on monthly basis complete all as specified and directed. |
| 45 | M&L, installation, commissioning and testing for converting 20 KW off grid solar system into on grid solar system by installing required equipment and accessories like- on grid inverter, ACDB, DCDB, power cable-4 core of adequate size, net meter ,control accessories etc and other necessary accessories and spares to make existing solar system on grid through net meter. complete testing shall be carried out after installation and commissioningto check the functionality of on grid solar system complete all as specified and directed.Note- 1. The existing off grid solar system of capacity 20 KW is functional.2. Unit rate to complete the job is inclusive of required equipment and accessories as discribed above .3. Bidder has advised to visit the site before quoting the rate . |
| 46 | Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.(ii) Make of material shall be as per mentioned in Particular specifications or Appendix \"B\" to Particular specifications as approved by AGE (I) AF manauri |