| 1 | Excavation for foundation in earth, soils of all types, sand, Gravel and soft murum, including removing the excavated material upto a distance of 50 m. beyond the building area stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering (including shoring and strutting) etc. complete. (Lift upto 1.50 Metre). by Mechanical means Spec. No. : Bd.A.1 Page No. 259. SSR I.No. 21.02 |
| 2 | Providing and laying cast in situ / Ready mix , cement concrete in M10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, form work, compacting, roughing them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reverisble drum type mixer/concrete batch mix plant (pan mixer) etc complete finishing if required and curing etc. complete. Spec. No. : Bdf3. SSR I.No. 24.01. Page. no. 217 |
| 3 | Providing and laying in situ / Ready mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete work in foundation like raft, grillages, strip foundation and footings of reinforced cement concrete columns and steel stanchionetc including bailing out water, form work, compaction and finishing, curingroughening the surface if special finish is to be provided (excluding reinforcemetn anf structural steel) etc. complete with fully automatic micro processor based PLC with SCADA enabled reverisble drum type mixer/concrete batch mix plant (pan mixer) etc complete with fine aggregate (Natural sand / CRushed sand VSI grade finely washed etc ) finishing if required and curing etc Spec. No. : Bd.F.3 Page No. 298. and B.7 , Page. No. 38 S.S.R.I. I.No. 25.11. |
| 4 | Providing and laying in situ / Ready mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete columns as per detailed design and drawing or as directed including steel centreing, formwork, , cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complte (excluding reinforcemetn anf structural steel) etc. complete with fully automatic micro processor based PLC with SCADA enabled reverisble drum type mixer/concrete batch mix plant (pan mixer) etc complete with fine aggregate (Natural sand / CRushed sand VSI grade finely washed etc ) finishing if required and curing etc Spec. No. : Bd.F.5 Page No. 300. and B.7 , Page. No. 38 S.S.R.I. I.No. 25.31 Page. No. 222. |
| 5 | Providing and laying in situ / Ready mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete beams and lintelsas per detailed design and drawing or as directed including steel centreing, formwork, , ocver blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complte (excluding reinforcemetn anf structural steel) etc. complete with fully automatic micro processor based PLC with SCADA enabled reverisble drum type mixer/concrete batch mix plant (pan mixer) etc complete with fine aggregate (Natural sand / CRushed sand VSI grade finely washed etc ) finishing if required and curing etc Spec. No. : Bd.F.6 Page No. 300. and B.7 , Page. No. 38 S.S.R.I. I.No. 25.50. |
| 6 | Providing and laying in situ / Ready mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete slabs and landings as per detailed design and drawing or as directed including steel centreing, formwork, , ocver blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complte (excluding reinforcemetn anf structural steel) etc. complete with fully automatic micro processor based PLC with SCADA enabled reverisble drum type mixer/concrete batch mix plant (pan mixer) etc complete with fine aggregate (Natural sand / CRushed sand VSI grade finely washed etc ) finishing if required and curing etc Spec. No. : Bd.F.8 Page No. 302. and B.7 , Page. No. 38 S.S.R.I. I.No. 25.70 |
| 7 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. DSR I.no. 26.33 |
| 8 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in plinth as backing in composite masonry including bailing out water manually, striking joints, raking out joints and watering etc Complete. SSSR I.No.27.01 |
| 9 | Filling in plinth and floors with contractor\"s soil, sand or murum in 15 cm. to 20 cm. layers includingwatering and compaction etc. complete. Spec. No. : Bd.A.11 Page No. 263. SSR I.No.21.37 |
| 10 | Providing internal cement plaster 20mm thick in two coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curingetc.complete. DSR I.no. 32.07 |
| 11 | Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete. a) Flooring DSR I.No. 33.40 |
| 12 | Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.dSR I.No. 32.34 |
| 13 | Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. DSR I.no. 35.21 |
| 14 | Providing and applying two coats of water proof cement paint of approved manufacture and of approved colour to the plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc.complete. DSR I.no. 35.13. |
| 15 | Providing and fixing board displaying information, such as \"Name of work, Tender cost, Name of contractor, work completion and liability period etc, having rectangular shape of 1.20 m x 0.90 m size made out 18 gauge (1.25m) thick mild steel sheet painted with one coat of zinc chromate stoving primer and two coats of zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border/ messages / symbos etc with approved colour shade paint complete, on M.S. angle of size 3 x 35 x 3 mm frame with properly cross braced M.S angle of size 35 mm x 35 mm x 3 mm duly painted including two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling transportatiion, and labour etc complete Spec. No. As directed by engineer in charge MORTH 801 S.S.R. I.No. 6.96 |