| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of50 m. All kinds of soil 2.8.1 |
| 2 | Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement: 4 coarse sand (zone-III) derived from natural sources :8 graded stone aggregate 40 mm nominal size derived from naturalsources) 4.1.8 |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived fromnatural sources) 4.1.2 |
| 4 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) 6.1.1 |
| 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) 6.4.1 |
| 6 | Cement plaster 1:6 (1 cement: 3 coarse sand) finished with cement. 12 mm cement plaster 13.4.2 |
| 7 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.With cement mortar 1:4 (1cement: 4 coarse sand) 14.1.2 |
| 8 | Providing and fixing panelled or panelled and glazed shutters for doors, window sand clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall bepaid separately)ck shutters Kiln seasoned selected planks of sheesham wood 35 mm thick shutters. 9.5.3.1 |
| 9 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete With second class teak wood beading 62X19 mm 9.51.1 |
| 10 | Renewing glass panes, with wooden fillets wherever necessary:Float glass panes of nominal thickness 5 mm (weight not less than12.5kg/sqm) 14.6.2 |
| 11 | Providing and fixing double action hydraulic floor spring of approved brand andmanufacture conforming to IS : 6315, having brand logo embossed on the body /plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.With stainless steel cover plate minimum 1.25 mm thickness 21.4.1 |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo Mechanically Treated bars of grade Fe-500D or more. 5.22.6 |
| 13 | Tile work in skirting, risers of steps and dado up to 2 m height over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade complete.Marble tiles (polished) Raj Nagar 8 mm thick 11.22.1.1 |
| 14 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, ofapproved brand & manufacturer, in all colours and shade, laid with cement based highpolymer modified quick set tile adhesive (water based) conforming to IS : 15477, inaverage 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm 11.49.2 |
| 15 | Providing and fixing unplasticised -PVC pipe clips of approved design tounplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs,screwed with M.S. screws of required length, including cutting brick work and fixingin cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm 12.43.2 |
| 16 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal dia Pipes Code no.18.9.2 |
| 17 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 15 mm dia nominal bore 18.12.1 |
| 18 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 20 mm dia nominal bore 18.12.2 |
| 19 | Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length 15 mm nominal bore 18.21.2.1 |
| 20 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete Flexible pipe 32 mm dia. 17.28.2.1 |
| 21 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge.14.79 |
| 22 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 18.48 |
| 23 | Painting Steel work with Deluxe Multi Surface Paint to give an evenshade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat ofprimer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 13.48.3 |
| 24 | Varnishing with varnish of approved brand and manufacture :Two or more coats of glue sizing with copal varnish over an under coat of flatting varnish 13.67.1 |
| 25 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.Code no.13.80 |
| 26 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.One coatCode no.13.82.1 |
| 27 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 13.88 |
| 28 | Finishing walls with textured exterior paint of required shade :Old work (Two or more coats on existing cement paint surface applied @ 3.28 ltr/10 sqm. 13.110.1 |
| 29 | Providing & fixing White vitreous china water closet squatting pan (Indian type) alongwith \"S\" or \"P\" trap including dismantling of old WC seat and \"S\" or \"P\" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm. 14.80.2 |
| 30 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete 10 litre capacity - White 17.18.1 |
| 31 | Providing and fixing false ceiling at all height including providing and fixing of frame workmade of special sections, power pressed from M.S. sheets and galvanized with zinc coating of120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mmwide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, otherflange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes ,finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint andtwo coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum moisture resistant board 12.45.3 |
| 32 | Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect CSI-29.134 NSI-134 |
| 33 | Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect.CSI. 29.135 (NSI-135) |
| 34 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet.CSI-28.4-DSR Code-1.24.4 |
| 35 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole.CSI-28.12 -DSR Code-2.10.1. |
| 36 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.CSI-28.7-DSR Code-1.14.2 |
| 37 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required CSI-28.10 -DSR Code-5.6 |
| 38 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required CSI-28.11 -DSR Code-5.12 |
| 39 | Providing and fixing in place a full height storage cabinet 600 mm deep made with 19 mm thick ISI marked ply borad, all interior surfaces to finished with pasting of 0.8 mm thick mica and all exterior surfaces to be finshed with pasting of 1 mm thick mica of texture and colour as approved by Engineer in Charge including all labour, T&P, other items like (but not limited to) fevicol, nails screws, higes, sliders,door handles, multipurpose lock of godrej or equivalent rate etc. required for proper completion of works, to be measured interms of front area only29.7(NSI-7) |
| 40 | Pre-Construction anti-termite treatment, by creating a barrier under and around the columns pits,foundation trenches, under floors, junctions of Walls & floors, around the external perimetre ofbuilding, expansion joints, surrounding of pipes and conduits etc. (Plinth area of the building at ground floor only shall be measured as per I.S. 6313 (Part II 1981))with Eldrine emulsifiable 0.2%concentration or any other approved material such as Heptachlore or chlordance will be used. The consumption of emulsion shall be (i) Foundation and masonary @ 5 Ltrs/Sqm, (ii) Back fills in immediate contact of foundation @ 7.5 Ltrs. / Sqm, (iii) Top surface of Plinth filling @ 5 Ltrs / Sqm,( iv) Junction of walls & floors @ 7.5 Ltrs / Sqm, (v) Soil along external perimetre of building @ 7.5Ltrs / Sqm (vi) under apron of the building @ 5 Ltrs. /Sqm. The rates includes cost of all materials,labour, equipments, T&P complete. (NSI-41)CSI. 29.41 (NSI-41) |
| 41 | Cleaning of septic tank including disposal of waste out side the UPPCL area as per direction of the Engineer-in-charge including cost of all labour,T&P etc.required for proper completion of the work CSI-29.59 -NSI-59 |
| 42 | Same as in NSI item No.59 above but for inspection chamber..CSI-29.60 -NSI-60 |
| 43 | Cleaning of main drain or width more than 300 mm.including disposal of waste refuses sludge outside the board\"s area including washing and cleaning by clean water completely as per direction of the Engineer-in-charge including cost of all labour,T&P etc.required for proper completion of the work.CSI-29.61 -NSI-61 |
| 44 | Cleaning and opening of chocked W.C./ bath / kithchen pipe line including opening and refixing of chamber cover including washing etc.complete. (Analysis based on NBO - 11 25.020.CSI-29.63 -NSI-63 |
| 45 | Cleaning and sweeping of roof of residence as and when required including uprooting of rank vegetation and disposal of the garbage upto 50 M.CSI-29.82 NSI-82 |
| 46 | Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)14.75A |
| 47 | Attending to petty maintenance service like plumbingservice,welder service, mansion service and carpenter servicerequired as below. (Job attending by one no. Plumber/welder/mason /carpenter with oneno. helper per hour or part of an hour.)CSI. 29.80 (NSI-80) |
| 48 | Supply and fixing of Single Concealed stop cock with basin spout (Composite one piece body) Jaquar make model no-FLR-5441NK . The work includes cost of all labour, material T&P for proper completion of work. CSI. 29.92(NSI-92) |
| 49 | S/F of Jaquar make pillar cock of model of FLR-5011N as per direction of engineer in charge. This include cost of labour, materialT&P etc for proper completion of work.CSI. 29.93 (NSI-93) |
| 50 | S/F of Jaquar make long body Bib Cock of model no CON-107PM as per direction of engineer in charge. This include cost of labour, materialT&P etc for proper completion of work.CSI. 29.100(NSI-100)CSI. |
| 51 | S/F of Jaquar make Towel Rail of model No. AQN 7711A 450 mm long as per direction of engineer in charge. This include cost of labour, material T&P etc for proper completion of work. CSI-29.102 (NSI-102) |
| 52 | Supply & installation of electrical control panel of L&T / Havells or equivalent make for submersible pump / pumpset containing contractor relay condenser. d) for 5 H.P pump set three phase CSI-29.54 -(NSI-54d) |
| 53 | Extraction of defective VT submersible pumps and motor with 60\" x 90\" column pipe and then lowering of the repaired pump and motor with pipe and testing the same including checking main cut-out fuse and operation of Tube well for 24 hours fo rits smooth working with all cost ofmaterials,labour and T&P etc required for the proper completion of the work.CSI-29.70 -(NSI-70) |