}

Tender For Renovation Works At District Tb Centre Wayanad District, Kerala, wayanad-Kerala

Hll Lifecare Limited has published Tender For Renovation Works At District Tb Centre Wayanad District, Kerala. Submission Date for this Tender is 10-05-2025. Building Work Tenders in wayanad Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

48920036
Corrigendum : Tender For Renovation Works At District Tb Centre Wayanad District, Kerala
Tender
Indian
Kerala
Wayanad
10-05-2025

Tender Details

Renovation Works At District Tb Centre Wayanad District, Kerala - 1 CIVIL WORKS 2 DISMANTILING AND DEMOLISHING 3 Demolishing brick work manually / by mechanical means including stacking ofserviceable material and disposal of unserviceable material within 50 metres lead asper direction of Engineer-in-Charge. In cement mortar 4 Dismantling steel work in built up sections in angles, tees, flats and channelsincluding all gusset plates,boltd, nuts, cutting rivets, welding etc. includingdismembering and stacking within 50 metres lead. 5 Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking thematerial within 50 metres lead of :G.S. Sheet 6 Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and falseceiling including disposal of unserviceable surplus material and stacking ofserviceable material with in 50 metres lead as directed by Engineer - in-Charge 7 Demolishing R.C.C. work manually / by mechanical means including stacking ofsteel bars and disposal of unserviceable material with in 50 metres lead as perdirection of Engineer -in-Charge. 8 Dismantling of plumbing pipe lines of 15mm dia to 110mm dia pipes, includingstacking of useful materials near the site and disposal of unserviceable materialswithin 50 metres lead as per the direction of engineer in-charge. 9 EARTHWORK EXCAVATION 10 Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil 11 PCC 12 Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering -All work upto plinth level1:4:8 (1 cement : 4 coarsesand : 8 graded stone aggregate 40 nominal size) 13 Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering -All work above plinth level up to floor fivelevel1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 14 RCC 15 Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo - MechanicallyTreated bars of grade Fe-500D or more 16 Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more 17 Providing and laying in position machine batched and machine mixed design mix M 25 grade cement concrete for reinforced cement concrete work, using cement contentas per approved design mix, including pumping of concrete to siteof laying butexcluding the cost of centering, shuttering, finishing and reinforcement, includingadmixtures in recommended proportions as per IS: 9103 to accelerate, retard settingof concrete, improve workability without impairing strength and durability as perdirection of Engineer - in-charge. .All work above plinth level upto floor V level 18 Providing and laying in position machine batched and machine mixed design mix M 25 grade cement concrete for reinforced cement concrete work, using cement contentas per approved design mix, including pumping of concrete to siteof laying butexcluding the cost of centering, shuttering, finishing and reinforcement, includingadmixtures in recommended proportions as per IS: 9103 to accelerate, retard settingof concrete, improve workability without impairing strength and durability as perdirection of Engineer - in-charge.All work upto plinth level. 19 Providing and supplying of Decking Sheet plates ofwidth 0.94m, thickness 1mm , crest height 51mm and width(top) 91mm, width (bottom) 143mm. The rate inclusive of material, transportation, scaffolding . as per the direction of Engineer in charge. ( The steel frame work should be paid seperately ) 20 FORM WORK 21 Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform 22 Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders bressumers and cantilevers 23 Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide 24 Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts 25 Centering and shuttering including strutting, etc. and removal of form for:Weathershade, Chajjas, corbels etc., including edges 26 MASONRY WORKS 27 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearestsize in cement mortar 1:6 for super structure above plinth level up to floor two levelincluding all cost of materials, labour charges etc. 28 STONE WORK 29 Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarsesand) 30 PLASTERING 31 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 32 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 33 DOORS AND WINDOWS 34 Providing and fixing to existing door frames24 mm thick factory made PVC doorshutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wallthickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and railsmitred and joint at the corners by means of M.S. galvanised/plastic brackets of size75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles ofthe shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm(± 0.1 mm) wall thickness. The lock rail made up of H section, a uPVC hollowsection of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness,fixed to the shutterstyles by means of plastic/galvanised M.S. U cleats. The shutter frame filled with auPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled verticallyand tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod andfastened with nuts and washers, complete as per manufacturers specification anddirection of Engineer-in-charge( For W.C. and bathroom door shutter). 35 Providing and fixing factory made uPVC door frame made of uPVC extrudedsections having an overall dimension as below (tolerance ±1 mm), with wall thickness2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized bracketsand stainless steel screws, joints mitred and plastic welded. The hinge side vertical ofthe frames reinforced by galvanized M.S. tube of size19 x 19 mm and 1 mm (± 0.1mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete asper manufacturers specification and direction of Engineer-in-chargeExtruded sectionprofile size 48x40 mm 36 Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating notless than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,with necessary screws complete:100x10 mm 37 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mmnominal size) 38 Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressedbutt hinges bright finished of required size with necessary screws. ( Shutter area to bemeasured) 39 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pairof handles of approved quality for aluminium door, with necessary screws etccomplete as per direction of Engineer- in- charge. 40 Providing and fixing 12 mm thick frameless toughened glass door shutter of approvedbrand and manufacture, including providing and fixing top & bottom pivot & springtype fixing arrangement and making necessary holes etc. for fixing required doorfittings, all complete as per direction of Engineer-in-charge ( Door handle, lock andstopper etc to be paid separately) 41 Providing and fixing of glass door SS Patch Lock with out handle in toughened glassdoor including all necessary screws etc. complete. . 42 Providing and fixing Steel S.S- 304 (D) DoorHandle of 450mm(1 Handles) ( bestmake of approved quality ) for Glass, Wooden or similar doors including necessarycutting and making good etc. complete 43 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I)decorative type, core of block board construction with frame of I st class hard woodand well matched teak 3 ply veneering with vertical grains or cross bands and faceveneers on both faces of shutters.35 mm thick including ISI marked Stainless Steelbutt hinges with necessary screws 44 Providing wood work in frames of doors, windows, clerestory windows and otherframes, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paid forseparately), using good quality Anjili wood /jack wood 45 TILE WORKS 46 Extra for providing opening or required size & shape for wash basin/kitchen sink inkitchen platform, vanity counter and similar location in marble/granite/ stone work,including necessary holes for pillar taps etc. including moulding, rubbing andpolishing of cut edges etc. complete. 47 Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm. 48 Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer -in Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm,including pointing in white cement mixed with pigment of matching shade complete. 49 Providing and laying Vitrified tiles indifferent sizes (thickness to be specified bymanufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622,ofapproved make, in all colours & shade, in skirting, riser of steps, over 12 mm thickbed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint withwhite cement & matching pigments etc. complete.Size of Tile 600x600 mm 50 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to bespecified by the manufacturer), of 1st quality conforming to IS : 15622, of approvedmake, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thickcement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints withwhite cement and matching pigment etc., complete. 51 Taking out existing CC interlocking paver blocks from footpath/ central verge,including removal of rubbish etc., disposal of unserviceable material to the dumpingground, for which payment shall be made separately and stacking of serviceablematerial within 50 metre lead as per direction of Engineer-in-Charge. 52 Laying old cement concrete interlocking paver blocks of any design/ shape laid inrequired line, level, curvature, colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as perthe direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by thedepartment free of cost.) 53 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded andprepolished, machine cut for kitchen platforms, vanity counters, window sills, faciasand similar locations, of required size, approved shade, colour and texture laid over20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated withwhite cement, mixed with matching pigment, epoxy touch ups, including rubbing,curing, moulding and polishing to edges to give high gloss finish etc. complete at alllevels. Granite stone slab of colour black , cherry / ruby red .Area of slab over 0.50sqm 54 Providing and laying 60 mm thick factory made cement concrete interlocking paverblock of M - 30 grade made by block making machine with strong vibratorycompaction, of approved size, design & shape, laid in required colour andpattern over and including 50 mm thick compacted bed of coarse sand, filling thejoints with fine sand etc. all complete as per the direction of Engineer-in-charge. 55 ALUMINIUM WORKS 56 Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 57 For shutters of doors, windows & ventilators including providing and fixing hinges /pivots and making provision for fixing of fittings wherever required including thecost of EPDM rubber/ neoprene gasket required (Fittings shall be paid forseparately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 58 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:125 mm 59 Providing and fixing aluminium extruded section body tubular type universalhydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body,door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), withdouble speed adjustment with necessary accessories and screws etc. complete. 60 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised(anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed torequired colour and shade, with necessary screws etc. complete.Twin rubber stopper 61 Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating notless than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,with necessary screws complete:200x10 mm 62 Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness 63 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:75 mm 64 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layeror graded wood particle board conforming to IS : 12823 Grade I Type II, in panellingfixed in aluminum doors, windows shutters and partition frames with C.P. brass /stainless steel screws etc. complete as per architectural drawings and directions ofEngineer - in- Charge.Pre- laminated particle board with decorative lamination onboth sides 65 Providing and fixing 100 mm brass locks ( best make of approved quality ) foraluminium doors including necessary cutting and making good etc. complete. 66 Providing and fixing glazing in door, window, ventilator shutters and partitions etc.with EPDM rubber /neoprene gasket etc. complete as per the architectural drawingsand the directions of engineer-in-charge . (Cost of aluminium snap beading shall bepaid in basic item): toughened glass of 6 mm thickness. 67 Providing and fixing frosted film in the fixed glass etc. Complete as per the directionof departmental officers 68 FALSE CEILING 69 Providing and fixing false ceiling at all height including providing and fixing of framework made of special sections, power pressed from M.S. sheets and galvanized withzinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting ofangle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mmdia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangersof 25x10x0.50 mm of required length with nuts & bolts of required size and other endof angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at thespacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thickbottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5 mm,at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I.intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm longG.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mmhigh having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed towall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wallscrews @ 230 mm interval, including fixing of gypsum board to ceiling section andperimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c,including jointing and finishing to a flush finish of tapered and square edges of theboard with recommended jointing compound, jointing tapes, finishing with jointingcompound in 3 layers covering upto 150 mm on both sides of joint and two coats ofprimer suitable for board, all as per manufacturers specification and also includingthe cost of making openings for light fittings, grills, diffusers, cutouts made withframe of perimeter channels suitably fixed, all complete as per drawings, specificationand direction of the Engineer in Charge but excluding the cost of painting with:12.5mm thick tapered edge gypsum moisture resistant board 70 Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm intrue horizontal level, suspended on inter locking metal grid of hot dipped galvanizedsteel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting ofmain T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to centerand cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mmlong spaced between main T at 600 mm center to center to form a grid of 1200x600mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mmthick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to formgrids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceilingtiles of approved texture in the grid including, required cutting/making, opening forservices like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main Trunners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at1200 mm center to center along main T, bottom exposed width of 24 mm of all T sections shall be pre-painted with polyester paint, all complete for all heights as perspecifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Layin perforated Tegular global white color tiles of size 595x595 mm and 0.5mm thickwith 8 mm drop; made of GI sheet having glavanizing of 100 gms/ sqm (both sidesinclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (NoiseReduction Coefficient) of 0.5, electro statically polyster powder coated of thickness60 microns (minimum), including factory painted after bending and perforation, andbacked with a black Glass fiber acoustical fleece. 71 STEEL WORK 72 Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steelprimer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 73 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished welded type tubes 74 Structural steel work riveted, bolted or welded in built up sections, trusses and framedwork, including cutting, hoisting, fixing in position and applying a priming coat ofapproved steel primer all complete. 75 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angleiron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittingscomplete, including applying a priming coat of approved steel primer.Using M.S.angels 40x40x6 mm for diagonal braces 76 Designing, fabricating, testing, installing and fixing in position Curtain Wall withAluminium Composite Panel Cladding, with open grooves for linear as well ascurvilinear portions of the building , for all heights and all levels etc. including: a)Structural analysis & design and preparation of shop drawings for pressureequalisation or rain screen principle as required, proper drainage of water to make itwatertight including checking of all the structural and functional design. b) Providing,fabricating and supplying and fixing panels of aluminium composite panel cladding inpan shape in metalic colour of approved shades made out of 4mm thick aluminiumcomposite panel material consisting of 3mm thick FR grade mineral core sandwichedbetween two Alumini um sheets (each0.5mm thick). The aluminium composite panelcladding sheet shall be coil coated, with Kynar 500based PVDF / Lumiflon basedfluoropolymer resin coating of approved colour and shade on face # 1 and polymer(Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts,washers, cleats, weather silicone sealant, backer rods etc. c) The fastening brackets ofAluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serratedwashers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts ofapproved make in SS 316, Nylon separators to prevent bi-metallic contacts allcomplete required to perform as per specification and drawing The item includes costof all material & labour component, the cost of all mock ups at site, cost of allsamples of the individual components for testing in an approved laboratory, field testson the assembled working curtain wall with aluminium composite panel cladding,cleaning and protection of the curtain wall with aluminium composite panel claddingtill the handing over of the building for occupation. Base frame work for ACPcladding is payable under the relevant aluminium item.s The Contractor shall providecurtain wall with aluminium composite panel cladding, having all the performancecharacteristics all complete , as per the Architectural drawings, as per itemdescription, as specified, as per the approved shop drawings and as directed by theEngineer-in-Charge. However, for the purpose of payment, only the actual area on theexternal face of the curtain wall with Aluminum Composite Panel Cladding(including width of groove) shall be measured in sqm. up to two decimal places. 77 MULTIWOOD WORKS 78 Providing and fixing panelling or Providing and fixing panelled or Making Shelf,Racks, Tables, etc : 19 mm thick Marine Ply wood with 1 mm thick laminate pastedand pressed with adhesive to give a uniform and smooth finish with 25 year warranty.(Area of opening for panel excluding portion inside grooves or rebates to bemeasured, no extra shall be paid for making openings, door / window frames andmaking provisions for electric conduits.) Shades, design, etc. as per the direction ofsite-in-charge 79 Providing and fixing 4 mm thick Veneer on plywood cupboard/reception counter/wardrobes etc. of approved make with necessary adhesive, complete as per directionof Engineer-inCharge. 80 Providing and fixing panelling or Providing and fixing panelled or Making Shelf,Racks, Tables, etc : 25 mm thick Marine Ply wood with 1 mm thick laminate pastedand pressed with adhesive to give a uniform and smooth finish. (Area of opening forpanel excluding portion inside grooves or rebates to be measured, no extra shall bepaid for making openings, door / window frames and making provisions for electricconduits.) Shades, design, etc. as per the direction of site-in-charge. 81 Providing and fixing 40mm thick cladding comprising of Wooden framework using25x50mm sections at a maximum spacing of 600mm in any one direction (includingadding members as required) covered with 12mm thick BWP ply layered with 4mmthk. veneer on one side pasted and pressed with adhesive to give a uniform andsmooth finish. including 4mm thk. S.S. strip framework on all sides of veneer panelswith wooden member surround, top moldings / margins, excluding primer and polishetc. to finish the thickness, as shown complete in drawing. All members / ply etc.shall be treated with anti- termite solution as per norms. No extra shall be paid formaking of openings, door / window frames and for making provisions for electricconduits.Details of cost for 10sqmAdd wastage @ 20% 82 Providing and fixing Thomson Multi wood board or equivalent make, in shelves withscrews and fittings wherever required, edges to be painted with polyurethane primer(fittings to be paid separately) as per the direction of site Engineer-in-charge. 83 Providing and fixing concealed hinge of approved quality for 19-20mm thick doorwith stainless steel screws complete : 84 Providing and fixing special quality bright finished brass cupboard or ward robe lockswith four levers of approved quality including necessary screws etc. complete.40 mm 85 Providing and fixing magnetic catcher of approved quality in cupboard/ward robeshutters, including fixing with necessary screws etc. complete.Triple strip verticaltype 86 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:75 mm 87 ROOFING 88 Supply Installation Testing & Commissioning (SITC) of color coated PUFroofing sheet with powder coated Galvanized Iron of 0.4 mm thick sheet on bothsides, 20 mm thick class O PUF sheetof size 40x35cm, min.40kg/m3density sandwiched in between. The surface shall be coated with 80-micron thickpowder coating by hot dip galvanizing with zinc coating not less than 180gm/sqmboth side of the panel. Scope includes runner, covings, interconnecting profiles, fixingarrangements, silicon sealant application and all other accessories required tocomplete the work as per site requirement, Silicon Sealant (Clear/White/WinselGray), complete with all necessary hardware, accessories, fittings and fixtures, as perdescription in individual items, technical specifications, drawings and instructions ofthe Engineer-In charge. 89 PAINTING 90 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare thesurface even and smooth complete. 91 Providing and applying plaster of paris putty of 2 mm thickness over plastered surfaceto prepare the surface even and smooth complete. 92 Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Two or more coats applied on walls @1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10sqm 93 Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Painting Steel work with Deluxe MultiSurface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqmover an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand andmanufacture 94 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additivesof required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over andincluding priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 95 Melamine polishing on wood work ( one or more coat) 96 Removing white or colour wash by scrapping and sand papering and preparing thesurface smooth including necessary repairs to scratches etc. complete. 97 PLUMBING 98 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Flat backwash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 99 Flexible pipe40 mm dia 100 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approvedquality and colour.Waste coupling 31 mm dia of 79 mm length and 62 mm breadthweighing not less than 45 gms 101 Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 31 mmsingle piece moulded with height of 270 mm, effective length of tail pipe 260 mmfrom the center of the waste coupling, 77 mm breadth with 25 mm minimum waterseal, weighing not less than 260 gms 102 Providing and fixing white vitreous china pedestal type water closet (European typeW.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, includingflush pipe, with manually controlled device (handle lever), conforming to IS : 7231,with all fittings and fixtures complete, including cutting and making good the wallsand floors wherever required:W.C. pan with ISI marked white solid plastic seat andlid 103 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge.Concealed work, including cutting chases and making good thewall etc.20 mm nominal outer dia pipes 104 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge.Concealed work, including cutting chases and making good thewall etc.32 mm nominal outer dia pipes 105 Providing and fixing ball valve (brass) of approved quality, High or low pressure,with plastic floats complete:15 mm nominal bore 106 Providing and fixing ball valve (brass) of approved quality, High or low pressure,with plastic floats complete:20 mm nominal bore 107 Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore 108 Providing and fixing PTMT extension nipple for water thank pipe, fittings ofapproved quality and colour .20 mm nominal bore, weighing not less than 40 gms 109 Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of Joints complete as per direction ofengineer in charge.110 mm dia 6Kgf/cm2 110 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00m spacing . This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge 110 mm dia 6Kgf/cm2 - External work- Exposed on wall 111 Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make )including cost of materials and labour charges etc complete as per the direction of siteEngineer-in-charge. 112 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, Collarand bush approved quality and colour .15 mm nominal bore with 45 cm length 113 Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore 114 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing . This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 6 Kgf/cm2 - Internal work- Exposed on wall 115 Providing and fixing C.P brass long nose bib cock of approved quality conforming toIS standards and weighing not less than 810 gms.15 mm nominal bore 116 Constructing soak pit 1.20x1.20 m filled with brickbats including S.W. drain pipe 100mm diameter and 1.20 m long complete as per standard design. 117 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approvedquality) complete with 6 mm thick hard board ground fixed to wooden cleats withC.P. brass screws and washers complete. 118 Supplying and fixing Stainless steel soap dish including cost of materials and labourcharges etc complete as per the direction of site Engineer-in-charge. 119 Supplying and fixing CP Towel rod 45cm or nearest available length including cost ofmaterials and labour charges etc complete as per the direction of site Engineer-in charge. 120 Providing and fixing square rain water gutter pipes including jointing.<br>150mm diameter 121 SIGNAGES 122 NAME BOARD ACP SHEET WITH MULTIWOOD LETTERING : Design,Supplying andfixing Name Board as per the technical specifications given -1 Inch GI pipe frame(16Guage) for Frame (Sizeproportional), Primer Paint & Black Painted Pipes for Frame.,5mm ACP sheets(Aluminum Composite Panel)for Box area, 18mm thick Multi wood Lettering for Name Board as approvedby Engineer incharge.For Measurement purpose, only area of ACP sheet to be measured 123 Design, providing and fixing Digital Printed vinyl signage boards with transparent3mm acrylic Sheet with 4 nos. SS Studs with lettering of size 15x45 cm. Complete asper the per the direction of Engineer in charge. 124 Providing and fixing up Multiwood Letter of Size 7 Inch Height & WidthProportional, over any surface as per the direction of site engineer in charge. Rateinclusive of labour, adhesives, etc. 125 Electrical 126 POINT WIRING 127 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B 128 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 129 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 130 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 131 CIRCUIT WIRING 132 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire 133 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 134 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire 135 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire 136 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 137 accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 138 SWITCHES AND SOCKETS 139 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch 140 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 141 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch 142 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 143 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 144 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) 145 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) 146 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator 147 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket 148 Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface 149 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module 150 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required Bell push 151 DB, ENCLOSURE 152 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 153 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43) 154 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door 155 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 156 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 157 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker with overcurrent protection (RCBO), having a sensitivity current upto 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A, 4P, 100mA 158 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current breaker with overload (RCBO), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 25A, 2P, 30mA 159 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 160 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 161 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps DP Isolator complete with connections, testing and commissioning etc. as required. 162 CABLE SUPPLY ,LAYING AND TERMINATION 163 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp 164 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 165 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 166 Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) 167 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 168 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) 169 EARTHING PROTECTION 170 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required 171 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) 172 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) 173 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 174 LIGHT AND FAN FIXTURES 175 SITC of 36 W (+/-2) high efficient recess mounted 600mm x 600mm soft glowing LED luminaire with system light output greater than 3600 lumens and system efficacy >110 lm/W, UGR<19. The luminaire must be energy efficient with CRI>80, CCT – 6500K, pf > 0.95, THD <10% SDCM<5, IP20 protection. The luminaire shall be flicker free with a ripple content less than 5 %. The luminaire must be BIS certified and must have LM79 and LM80 reports from NABL certified labs. The luminaire housing shall be made of CRCA and prismatic polystyrene diffuser with high transparency coefficient and a lifetime of 50,000 burning hours as per L70B50 criteria, 2.5 kV internal surge protection, including all accessories necessary as required to complete installation. 176 SITC of 10 W (+/-2) high efficient recess mounted LED circular/square down lighter with white powder coated, pressure die cast aluminum housing, a polycarbonate diffuser and a sleek design of product height not more than 40 mm. The luminaire shall have a CCT of 6500 K, CRI>80, power factor>0.9 and THD <10 %. The luminaire shall be EMI/ EMC compliant. The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports shall be submitted. The luminaire shall have a non-integral LED driver with 50,000 burning hours as per L70B50 criteria, ambient temp-0 to 45 o C, 2.5 kV surge protection, and inbuilt electronic driver, luminaire efficacy > 110 lm/W including all accessories necessary as required to complete installation. 177 SITC of 4 feet surface mounted batten type luminaire with a power consumption not more than 20 W, luminaire lumen output of 2400 lumens, luminaire efficacy > 120 lm/W with an operating voltage range from 140 V - 270 V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and a sleek design with width not more than . The luminaire shall have a CCT of 4000K ,6500 K , CRI > 80, power factor >0.95, SDCM < 5, THD <10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content <5% and shall have high and low cut off with auto restart feature. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 kV. The luminaire shall have Class - 1 Electrical Insulation, Class - B Serviceability (The driver can be replaced at site level). The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports from NABL accredited labs. 178 SITC of 2 feet surface mounted batten type luminaire with a power consumption not more than 10 W, luminaire lumen output of 1200 lumens, luminaire efficacy > 120 lm/W with an operating voltage range from 140 V - 270 V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and a sleek design with width not more than . The luminaire shall have a CCT of 4000K ,6500 K , CRI > 80, power factor >0.95, SDCM < 5, THD <10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content <5% and shall have high and low cut off with auto restart feature. The luminaireshall be EMI/ EMC compliant and shall have a internal surge protection of 4 kV. The luminaire shall have Class - 1 Electrical Insulation, Class - B Serviceability (The driver can be replaced at site level). The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports from NABL accredited labs. 179 SITC of EXHAUST FAN,SHUTTER TYPE white colour, 9 OR 10 star rated as per BEE complete with its all accessories including mounting accessories. 180 Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply 181 UPS 182 Supply installation, testing and commissioning of following single phase to single phase 6KVA UPS with inbuilt battery backup, indoor (IP20) in stand alone configuration, true online double conversion DSP based UPS system, with 30 min backup battery with, input pf>.9, less input current consumption, with input 230V single phase, output 230V single phase , IGBT rectifier and IGBT inverter. It shall be 100% generator compatible with efficiency > 90% and output power factor > 0.8 and including all accessories etc as required. The UPS system shall be with manual maintenance bypass switch facility. The system shall comply to IEC /EN 62040-1 and relevant IS standard and.The acoustic noise of the system should be less than 58dB. The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3 and relevant IS standard. 6kVA UPS - 1 Nos, Battery Circuit Breaker-1 nos, Battery Required nos. of SMF for providing 30 Minutes Backup and Battery Accessories like battery rack, interconnecting cables etc. 183 DISMANTLING 184 Electrical Labour works Dismantling of existing ceiling fan, light fittings, Switch Boards, DB Boards (SPN &TPN) using mechanical means or physical means without disturbing the overall structure of proposed area. All items dismantled and shall be made a checklist for returning back to concerned Authorities. All items shall be verified by ElectricalEngineer (HLL) before handing over. If any working product is damaged during transit, the same shall be replaced without any additional claim. 185 Dismantling of existing meter board, removing and rewiring the connections to the meter board after informing the KSEB authorities about meter shifting. 186 Dismantling of ceiling fan and painting the same with with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins reinstalling the same as required. 187 Dismantling, re installation and commissioning of HiWall Split AC (IDU and ODU) units (1.0TR/1.5TR/2.0TR) with water service, gas top up, including all necessary fittings for recommissioning complete as required as per the direction of Engineer in charge. 188 DOCUMENTATION AND APPROVAL 189 DOCUMENTATION AND APPROVAL - Charges for Preparation of all drawings submitting and getting approval from KSEB, submitting of Completion certificates and arranging inspection, getting sanction from KSEB, obtaining power allocation if necessary & power connection etc. for commissioning of the whole installation in the premises. All statutory payments will be reimbursed on production of the original receipts 190 PA SYSTEM 191 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.speaker cable Two pair, 2-core, 1.5 sqmm 192 SITC OF Light weight Potable Tripod projector stand omes with a fold-up tray that provides a secure tilting platform for most projectors. Its tilt adjustment ensures optimal viewing angles. Removable tray quickly detaches to easily pack into theincluded nylon carry bag. The included straps add additional support and safety. Retractable folding tripod legs with locking paddles are ideal for transport and storage. Built-in bubble level keeps proper leveling. Anti-skid feet ensure stability and prevent the surface from scratches. This stand can also support other devices including laptops, cameras, tablets and DJ equipment. Perfect for home, offices, camps, presentations, stage and other applications 193 SITC OF Professional 3-Way 250 w speaker system consisting of one high efficiency, high SPL 15” LF speaker, a 1” HF Compression Driver and two Piezo Tweeters, for excellent high frequency response. The speaker system has a high efficiency that makes it particularly good value as high levels of acoustic power can be achieved without drawing excessive power from the amplifier. The system is housed in a Rugged Bass Reflex Trapezoidal Enclosure made of 18mm board, and Carpet covered. A Stand Adapter is provided at the bottom for stand mounting. The trapezoidal cabinet design assures optimum low frequency performance. An On/Off switch for the piezo speakers is provided to limit extended HF if desired. The speaker is ideal for PA as well as music performances. 194 SITC OF Professional high quality PA Gooseneck Microphones are suitable for various PA applications such as on Lecterns and Podiums, Open Conferences etc. The sleek and slender design makes the microphones unobtrusive. fitted with stand mount base and are supplied with 6 mtrs twin core shielded low noise cable.Wide frequency response.High front-to-back rejection for more gain before feedback.Built-in XLR socket. Frequency Response 50-15,000Hz Impedance 500 Sensitivity 2.2mV/Pa Overall Length 395mm (15½”) 195 SITC OF 1000 Watts High Wattage PA Power Amplifier with Line Input 200mV/1V switchable for connecting a mixer or another amplifier.100V input for connecting another amplifier output. Resettable circuit breaker for protection against overload and short circuit. 196 Brightness, 20000:1 High Contrast Ratio, Dual Hdmi, Upto 15000 Hrs Extra-Long Lamp Life, 10W Speaker, 3D Capable, White Connectivity Technology with VGA, USB, HDMI Display resolution1280 x 800 native resolution 1280 x 800 light source life 15000 hours 197 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 198 NETWORKING AND TELEPHONE 199 Supply, installation, testing and commissioning of CAT6A Information Outlet, RJ45 with all accessoriesrequired at site to complete the work as per technical specification 200 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required2 run of Cable 201 Supply,Installation,Testing &Commissioning of CAT6 Patch Cord with Moulded boots Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable.- 2Meter 202 Supply, Installation, Testing & Commissioning of 8 Port Network Switch with 8 Nos of 10/100/1000 ports and 2 Gigabit Copper/ SFP Combo ports for uplink 203 Supply, Installation, Testing & Commissioning of 6U Network Rack with below specifications as minimum and all the necessary accessories: - Lock & Keys - Tray (1 No) - 1 Cooling Fan and Adjustable Shelf - Height - 6U - Fan Units with 1coolin Fans - PDU point - Mounting Hardware Kit (1 lot) - Tray - Front glass doors and back steel door and side panels 204 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module 205 SITC Of Krone Box 10 Pair 206 Supply, Installation, Integration and Commissioning of 8 Lines EPABX Intercom System along with krone module as per the direction from Engineer in charge 207 Supply of User Phone- Analog phone 208 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet 209 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair 210 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet 211 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 212 AIR CONDITIONING 213 Supply and fixing of M.S OUTDOOR STAND for Split ACs. The work involves supply of heavy duty powder coated mounting bracket for outdoor unit with mounting bolts, complete as required and as directed by the Engr.-in-Charge 214 Supply & installation of STABILIZER suitable for 2.0TR Capacity Split AC units inclusive of all necessary wiring/connection. Stabilizer should comply with the detailed specification mentioned below. Intelligent Time Delay System, Latest IC Technology - Assures reliable protection, Wall Mounting Cabinet Design - Elegant and easy to install, Low & High Voltage cut-off Protection, Built-In Thermal Overload Protection - Protects the stabilizer and compressors during high-temperature burnout, Working Rage Voltage 170 VAC - 270 VAC.Make: V Guard/Vstab / Microtek or Equivalent with ISI Standard. 215 Supply & installation of Stabilizer suitable for 1.0TR/1.5TR Capacity Split AC units inclusive of all necessary wiring/connection. Stabilizer should comply with the detailed specification mentioned below. Intelligent Time Delay System, Latest IC Technology - Assures reliable protection, Wall Mounting Cabinet Design - Elegant and easy to install, Low & High Voltage cut-off Protection, Built-In Thermal Overload Protection - Protects the stabilizer and compressors during high-temperature burnout, Working Rage Voltage 170 VAC - 270 VAC Make: V-Guard/Vstab / Microtek or Equivalent with ISI Standard. 216 Drain Piping for Split ACs: Supply & installation of PVC insulated piping for condensate drain Including wall chasing, necessary supports, Clamps etc complete as required 217 Additional refrigerant Copper piping Kit for Split ACs : Supplying and installation of additional refrigerant piping kit consisting of power and control cables, good quality copper tubing, Elastomeric Nitrile rubber insulation etc. for Split AC units. 218 Supply, Installation, Testing and Commissioning of 2.0TR - 3 Star rated Inverter type split AC units , Hi-wall mounted, preferably with anti corrosive / powder coated outdoor units, fitted with hermitically sealed suction cooled energy efficient Scroll / Rotary compressor operating on R-32 / HFC-134a / 407 C / 410 A refrigerant suitable for operation on 220 V, 1 Ph, 50 Hz A/C supply. The units shall be inclusive of all standard accessories like power & control cables, good quality copper tubing of minimum 3 meter length to interconnect the outdoor unit with indoor unit for refrigerant lines, elastomeric Nitrile rubber insulation, clamps etc. Notes: (1) Condenser tubes, Evaporator tubes & connecting pipes should be made out of good quality copper. (2) High-energy efficient compressor of rotary / Scroll type (3) Cordless remote for setting Temp, on time, off time, power saving mode, auto mode operation, sleep mode, auto setting with memory backup, time delay feature, programmable timer, etc. with real time clock. (4) Warranty: 5 Years on PCB, 10 years warranty on compressor and one year warranty for the total system from the date of handing over/ commissioning Make: Blue Star / Voltas / Carrier Midea / Hitachi / Daikin / Panasonic / Mitsubishi / Toshiba / Trane / O General or equivalent 219 Supply, Installation, Testing and Commissioning of 1.5TR - 3 Star rated Inverter type split AC units , Hi-wall mounted, preferably with anti corrosive / powder coated outdoor units, fitted with hermitically sealed suction cooled energy efficient Scroll / Rotary compressor operating on R-32 / HFC-134a / 407 C / 410 A refrigerant suitable for operation on 220 V, 1 Ph, 50 Hz A/C supply. The units shall be inclusive of all standard accessories like power & control cables, good quality copper tubing of minimum 3 meter length to interconnect the outdoor unit with indoor unit for refrigerant lines, elastomeric Nitrile rubber insulation, clamps etc. Notes: (1) Condenser tubes, Evaporator tubes & connecting pipes should be made out of good quality copper. (2) High-energy efficient compressor of rotary / Scroll type (3) Cordless remote for setting Temp, on time, off time, power saving mode, auto mode operation, sleep mode, auto setting with memory backup, time delay feature, programmable timer, etc. with real time clock. (4) Warranty: 5 Years on PCB, 10 years warranty on compressor and one year warranty for the total system from the date of handing over/ commissioning Make: Blue Star / Voltas / Carrier Midea / Hitachi / Daikin / Panasonic / Mitsubishi / Toshiba / Trane / O General or equivalent

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 08-05-2025 Date 1 Date 10-05-2025

Key Value

Document Fees
INR 2950 /-
EMD
INR 100000.0 /-
Tender Value
INR 58.24 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail