Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 08-05-2025 | Time Extension | Date | 15-05-2025 |
| 2 | 08-05-2025 | Due Date Extended for tenders closing on 07-05-2025. | Admin Corrigendum Date Extend | 10-05-2025 |
| Sl. No. | Item Description |
| 1 | Supplying and laying HMS PVC conduit FRLS grade 32mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 2 | Supplying & erecting GI flexible Conduit 50 mm dia. conforming to I.S. with required number of couplings, bushes, check nuts etc. complete |
| 3 | Supplying & erecting GI flexible Conduit 40 mm dia. conforming to I.S. with required number of couplings, bushes, check nuts etc. complete |
| 4 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 5 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 6 | Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 7 | Supplying & erecting GI flexible Conduit 25 mm dia. conforming to I.S. with required number of couplings, bushes, check nuts etc. complete |
| 8 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 9 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 10 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 11 | Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 12 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 13 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 14 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 15 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 16 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG PW/CW |
| 17 | Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/ CW |
| 18 | Point wiring for independent plug, concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wires,modular type switch, earthing and required accessories as per specification No WG-PW/SW |
| 19 | Supplying and erecting PVC insulated PVC round sheathed 4 sq.mm (56 no. x 0.30 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV |
| 20 | SITC of Industrial type 20Amp SP MCB with 20A ray roll type, 3pin plug & socket with cap & chain etc. |
| 21 | Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW |
| 22 | Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete.. |
| 23 | Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 24 | Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty |
| 25 | Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty. |
| 26 | Supplying and erecting motion sensor LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty |
| 27 | Supplying LED concealed type foot / step light with aluminium body for indoor/outdoor application suitable for 4W-6W LED including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with 1 year warranty |
| 28 | Supplying and erecting with allunimium profiles strip upto 20mmLED Strip light 5m Length Max. 45 W IP20 class having minimum lumens output of 800 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD<10%, p.f. >0.95, operating range of 230-270V, Life class of 30,000 Hrs. at L70B50, including driver with 1 year warranty. |
| 29 | Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF |
| 30 | Supplying and erecting ISI mark modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 31 | Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia.or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab. |
| 32 | Supplying and erecting ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. |
| 33 | Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation. |
| 34 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 35 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 36 | Supplying, fixing and commissioning 2 pole, RCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO |
| 37 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 38 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 39 | Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 40 | Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO |
| 41 | Providing & erecting floor / wall mounting, MCCB panel board with door suitable for four pole incoming 250A, 8 ways Four pole outgoing upto 100 A MCCB\"s on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCB\"S) |
| 42 | Providing & erecting 4 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides,with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 43 | Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 44 | Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 45 | Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box / panel and duly connecting with necessary PVC wire leads and lugs. |
| 46 | Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc. |
| 47 | Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.. |
| 48 | Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard |
| 49 | Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 50 | Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.. |
| 51 | Supplying and erecting GI sheet 1.6 mm (16 SWG) having zinc coating of 350 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling,welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 52 | Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 8 way outgoing or 400A incoming and 6 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB |
| 53 | Supplying and erecting 30 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating , APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC |
| 54 | Providing and fabricating structural steel work in cuplock sections as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. |
| 55 | Supplying and erecting ON LOAD four pole automatic transfer switch, 415V, 200A, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 . |
| 56 | Supplying and erecting triple pole mini feeder pillar with 500V, 200A FPMCCB as incomer and 2 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet box with supporting angles, self locks, gasket having IP54,IK10 protection and slanting top to be erected on provided foundation complete as per specification no. SW SWR/MFP |
| 57 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 58 | Supplying, erecting & terminating XLPE armoured cable 4 core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 59 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL |
| 60 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 61 | Supplying, erecting, testing and commissioning of diesel generating set CPCB - IV with alternator of 125 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per CPCB - IV+ as per engineering Incharge |
| 62 | Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 100 kVA up to 125 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. |
| 63 | Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 64 | Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. |
| 65 | Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950- 1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) |
| 66 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). |
| 67 | Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner. |
| 68 | Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware |
| 69 | Supply, Installation, Testing and commissioning of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. Specification no. EA-MOBI |
| 70 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no.EA-EP |
| 71 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 72 | Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP. |
| 73 | Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. |
| 74 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 75 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 76 | Supplying & laying (including excavation) 25 cm Dia half round RCC Hume pipe of standard thickness at required depth up to 90 cms. below road / ground surface, for enclosing provided cable & necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet). |
| 77 | Making trench in Hard murum/Tar road having 0.75 m depth and minimum 0.3mtr width as per IS for laying provided cables up to voltage level 1.1Kv cable complete as per specification No. CW-EXN-CTR |
| 78 | Carrying out core cutting of size 3\" to 5\" dia x 15\" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. |
| 79 | Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200) |
| 80 | Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. APWCR/WC |
| 81 | Supplying and installing cat-6 cable with rodent proof and anti termite jacket suitable for networking as per specification No. WG-COC/NC |
| 82 | Supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 Volts 50 cycles 1440 RPM without speed regulator, metallic blades, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 meter length and hand shield type 3 pin6A. plug top complete with moisture proof treatment and ‘E’ class insulation |
| 83 | Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s. A.C. supply, having delivery head from 27 to 9 m and discharge from 300 to 660 litres. per minute & pipe of Suction 65mm /Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP |
| 84 | Supplying & erecting flat flexible 3 core 2.5 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 85 | Supplying & erecting Water lavel controller 230/ 415V AC., Four way for under ground & Over head tank operation. |
| 86 | Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.c. Submersible/centrifugal pump set upto 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P.,Combined ammeter/voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc |
| 87 | Supplying & erecting Float sensor switch for water level controller working on 250V & rated current 8A, with 2 mtr. wire & High quality of wire & plastic body. |
| 88 | Supplying & erecting inline cut point end pole D. P. Structure for 11/0.415 kV, 200 KVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 400 Amps as incomer & 6 Nos. 200 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos. Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer. Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 176 Kg. iron work) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete. |
| 89 | Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 315 kVA, Mineral oil immersed and naturally cooled outdoor type, Copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%,+5 to -10 in steps of 2.5%, having 7 number of tap positions with standard accessories complete with test certificate with losses below 1025 Watts at 50% load, 3100 Watts at 100% load as per IS:1180 (part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL. |
| 90 | Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6mm., straining screws, G.l. stay wire 7/10 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. |
| 91 | Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay). |
| 92 | Supplying and erecting ACSR conductor of size 6/1-2.59 mm complete. (Weasel) (127.7 kg/km) as per specification No. OH-CON/ACSR |
| 93 | Supplying and erecting V cross arm with ISM channel of 75x40x6mm for 11kV HT OH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1220mm bent at angle of 60 degree keeping base 305mm and the total vertical height of V cross arm as 460mm, and fixed on pole with MS clamp of 80x10 mm, nut bolts, washers complete as per specification no. OH-PL/VCA |
| 94 | Supplying & erecting MS pole bracket for guarding/LT OH line, fabricated from angle iron 50x50x6mm and 1100mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT |
| 95 | Supplying and erecting pin type LT medium insulator 100mmx 62mm dia. with suitable G.l. spindle, nut, bolts complete. |
| 96 | Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. |
| 97 | Supplying and erecting 3 phase 4 core 95 sq.mm. (3x95+1x70) Aerial bunched aluminium cable along with necessary accessories for LT distribution on provided LT pole as per specification no. OH-CBL/ABC |
| 98 | Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ |
| 99 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). |
| 100 | \"Cost of lisaning to MESDCL ChargesCoordination with MSEDCL obtaining scheme sanction and release of power supply including metering connection. The cost also includes cost of metering of respective capacity as per the approval of MSEDCL. The scope also includes providing erecting, testing and commissioning of meters Preparation of schematic & detailed drawings as required by statutory authority and submission of the same in required sets to the statutory authority on behalf of MTDC, obtaining the approval for commencement and commissioning of the work. Payment of charges/fees to statutory authority/MSEDCL, Coordinating with authority for the site visit, and submission of its built drawings in 3 sets in hard and soft copy\" |
| 101 | Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 102 | Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 103 | Supplying & erecting 20 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly-al laminate moisture barrier, laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 104 | Supplying, erecting & commissioning 20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW |
| 105 | Supplying, erecting & commissioning 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW |
| 106 | Supplying, installing, testing & commissioning push button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete. |
| 107 | Supplying, installing, testing & commissioning IP telephone instrument as per specification complete. |
| 108 | Supplying, erecting, testing and commissioning of single phase input & 1 phase output 1 kVA capacity online pure sine wave UPS, with backup time of 01 hrs. PWM & IGBT based, with 0.8 to unity output pf complete with all protections as per specification no. AP-UPS |
| 109 | Supplying & erecting 50 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly-al laminate moisture barrier, laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 110 | Supplying, erecting & commissioning MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW |
| 111 | Supplying, installing, testing & commissioning digital (hybrid) type EPABX of 6 x 16 extension complete |
| 112 | Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG |
| 113 | Supplying, fixing, and configuring modularised multi-service router 802.11/a/n/ac unified Wave 2.5 GHz, with RJ-45 port, supporting 1 to 13 channels for 2.4 GHz, with unified wireless access point complete. |
| 114 | Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC |
| 115 | Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO |
| 116 | Supplying and fixing tool-less shutter keystone jack (RJ-45) in provided patch panel complete as per specification no. WG-NAS/KJ |
| 117 | Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP |
| 118 | Supplying and fixing 24 ports light guide unloaded interconnect unit, rack mounted type, with adapter panel for termination of optical fibre cables in provided U rack complete as per specification no. WG-NAS/ LIU |
| 119 | Supplying and fixing SC/SC type multimode pigtails (OM3) for LIU to terminate OFC in LIU as per specification No. WG-NAS/LIU2 |
| 120 | Supplying and fixing POE adaptor to provide DC supply to ethernet devices as per specification No. WG-NAS/PEA |
| 121 | Supplying and fixing Power Distribution Unit for networking rack comprises of 6/16A (6 Nos. sockets), 25 A modular MCB, appropriate rating fuse and indicator lamp, enclosed in black powder coated metal with necessary arrangement for fixing as per specification No. WG-NAS/RAK |
| 122 | Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK |
| 123 | Supplying and fixing manageable wireless 2x2 Mesh Router, 50 m range, dualband 802.11 n/ac unified wireless access point complete as per specification no. WG-NAS/LAP1 |
| 124 | Supplying and installing armoured single mode optical fibre cable with 6 fiber, core dia 50/125μm (OS1/OS2) 10/40 GBPS speed in provided underground HDPE pipe complete. |
| 125 | Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC |
| 126 | Supplying and fixing 2 m UTP patch cord of cat 6 type in position as per specification No. WG-COC/PC |
| 127 | Supplying and errectingIP DOME 5 MPProgressive ScanIllumination: 30 MtrWDRLux withLens: 4 -mmDay &Night: IR cut filter. Dynamic Range: Digital WDR Video compensation: Yes. Zone optional Alarm Trigger: Motion detection, Tampering alarm, Network disconnect, IP address confict, Storage full , Storage error Protocols: TCP /IP ,ICMP,HTTP,HTTP S, FTP, DHCP, DNS, DDNS, RTP, RTSP RTCP, PoE, NTP, UPnP, SMTP, SNMP ,IGMP, 802.1X, QoS, IPv6, Bonjour Security: User Authentication, Communication Interface: 1 RJ45 10M/100M Ethernet interface GBIP66 Impact Protection: IEC60068-275Eh, 20J; EN50102, up to IK10 IR Range: 20 meters Dimensions: Φ 140 × 99.9 mm (Φ 5.51\" × 3.94\")(Similar to Hikvision Make) |
| 128 | Supplying and errectingIP BULLET 5 MP 30 mtr Progressive Scan CMOS Min. 3.6mm @ F1.4, Lens Mount: Φ14 Day & Night: IR cut filter with auto switch Digital Noise Reduction: 3D DNR Wide Dynamic Range: Digital WDR Video compensation: Yes. Zone optional Alarm Trigger: Motion detection, Tampering alarm, Network disconnect, IP address confict, Storage full , Storage error Protocols TCP/IP, ICMP, HTTP, HTTPS, FTP, D HCP, DNS, DDNS, RTP, RTSP, RTCP, PoE, NTP, UPnP, SMTP, SNMP, IGMP, 802.1X,QoS,IPv6,BonjourSecurity: User Authentication, Communication Interface: 1 RJ45 10M/100M Ethernet interface IR Range: 20 meters Dimensions: Φ 140 × 99.9 mm (Φ 5.51\" × 3.94\")(Similar to Hikvision Make) |
| 129 | Providing and installing 32 chanel NVR /DVR with 8 TB Hard Disc storage capacity with all material complete. |
| 130 | Supplying and installing DVR rack with all accessories complete. |
| 131 | Supplying and installing BNC/DC Connector with all accessories complete. |
| 132 | Monitor - Supplying and installing43 \" LED TV (Sony KLV-32R412C or Simillar) having features such as ELECTRONIC PROGRAMME GUIDE (EPG), USB viewer supports FAT16, FAT32 and NTFS file systems, Multiple Indian Languages, Parental Control,Audio Power Output of minimum 8W+8W+14W (DOLBY® DIGITAL / DOLBY® DIGITAL PLUS / DOLBY® PULSE), HD Ready (1366 x 768) resolution with aspect ration of 16:9, Viewing Angle (UP / DOWN): 178 (89/89) degree, Minimum 2 HDMI and 1 USB inputs etc. with remote, Batteries, AC Power Adaptor, AC Power Cord, Table Top Stand including all leads-lifts as directed by Engineer in Charge. |
| 133 | SITC of Compact Air Cooled type outdoor units of VRV system having hermetically sealed scroll type compressors 100% inverter compressor, condenser coil fabricated from Seamless Copper tube & Plate type Al. Fins of Multi Row, Axial Flow, upward throw condenser fan, Condenser fan - motor unit, insulated refrigeration piping, power / control wiring, and earthing, external wiring between Indoor & Outdoor units. ODU shall be with Anti Corrosive Coating. Each Outdoor units with High Pressure switch, Fan driver overload protector, Over current relay, Inverter Overload Protector & Fusible Plug. The unit shall be suitable for 415 ± 10 % volts, 50 Hz, 3 phase AC supply, and IP 65 protection.The cost of ELCB should be included. The configuation of Outdoor units shall be selected to acheive the max. COP (min. 3.28 COP as per ECBC guidelines). ( VRF ODU with Scroll Inverter Compressor with 2 nos compressor.) |
| 134 | Supply Installation Testing & commissioning AHU Controller / distribution kit of suitable capacity for connecting multi VRF ODU to DX AHU, with a) built in auto restart function, c) with necessary electrical ( AHU kit (15HP +10HP)) |
| 135 | Supply, Installation, Testing and Commissioning of Refnets as specified of pipe sizes from 1/4 \" to 2\" ( IDU Refnet ) |
| 136 | Installation, Testing and Commissioning of VRF ODU along with Electrical Power Cable |
| 137 | Installation ,Testing & Commissioning of AHU kit with thermostat along with Refnet |
| 138 | Supply, Installation, Testing & Commissioning of seamless heavy gauge Copper piping of adequate size duly insulated with 13 mm thk. Nitrile Rubber Insulation. Refrigeration piping will have to be taken in the piping rack / Support individually connecting to all indoor units for the respective floors. Even necessary supports, fittings, valves & ref. joints where ever required will be included. ( Copper piping with suitable size insulation ) |
| 139 | Supply and Installation Communication / Control Cabling between Outdoor Units & Indoor Units, Communication cabling between the individual controllers to the main central controller with PVC conduits or Cable Trays if required. Of 3 core 1.5sqmm with flexible Conduit |
| 140 | Providing and fixing in position the following pipes cut to required lengths and necessary fitting with 9 mm thk.Nitrile Rubber Insulation as per drawing. |
| 141 | Supply and Installation of AHU DX type 6 row Floor Mounted AHU(Direct Driven Fan along with VFD) mixing box, pre& fine filter= 17.5TR/6500 CFM/35mm ESP with Electrical Starter panel 2.4Kw and electrical power Cable (Make : Citizen, Flakgroup,VTS ,Zeco) |
| 142 | Supply and installation of MS structural supports for AC ODU & Equipments including M.S \"C\" Channels, I Beams, Checkered Plates, Angles, M.S Pipes for M.S platform. The rate to be inclusive of painting 2 coats with synthetic epoxy paint with all accessories etc., to complete the foundation for Equipment & Pipes. |
| 143 | Supply, Fabrication, installation and testing of sheet metal ducts in accordance with the approved shop drawings and as required by the specifications. For GI Ducts with 180 GSM coating, External SP upto 500 Pa. Rectrangular ducting complete with elbows, turning vanes, neoprene / PVC gaskets, GI fully threaded rods, hot dip G.I. supports / slotted chanells / hangers etc. Duct Pressure Class - 2 inch W.G with intermediate bracing @ every 1200 mm as per approved shop drawings. The sealant used for general purpose like duct sealing or any other leakage proofing shall have the VOC limit of 500 g/L less water. The duct work and duct sealing shall be done as per ASHRAE 90.1: 2007, clause 6.4.4.2 to meet the Green building standards.Irrespective of standards considered 26 Guage duct & Slip on duct joints to maintain the quality , so contractor has to consider minimum 22 Gauge Duct & TDF Joints. All Exposed Ventilation Ducts , Dampers & Supports shall be with Anti Corrossive painting. 22G |
| 144 | Supply, Fabrication, installation and testing of sheet metal ducts in accordance with the approved shop drawings and as required by the specifications. For GI Ducts with 180 GSM coating, External SP upto 500 Pa. Rectrangular ducting complete with elbows, turning vanes, neoprene / PVC gaskets, GI fully threaded rods, hot dip G.I. supports / slotted chanells / hangers etc. Duct Pressure Class - 2 inch W.G with intermediate bracing @ every 1200 mm as per approved shop drawings. The sealant used for general purpose like duct sealing or any other leakage proofing shall have the VOC limit of 500 g/L less water. The duct work and duct sealing shall be done as per ASHRAE 90.1: 2007, clause 6.4.4.2 to meet the Green building standards.Irrespective of standards considered 26 Guage duct & Slip on duct joints to maintain the quality , so contractor has to consider minimum 24 Gauge Duct & TDF Joints. All Exposed Ventilation Ducts , Dampers & Supports shall be with Anti Corrossive painting. 24G |
| 145 | Supply & Installation of open cell, super silent, microbe resistant, Low VOC Accoustic insulation in supply air ducting internally with nitrile rubber below mentioned thickness as per approved drawing and specifications. The material shall be antifungal in nature and tested to ASTM G21 standard of 15mm |
| 146 | Supply & Installation of closed cell Thermal insulation over supply air ducting externally with electromeric nitrile rubber with factory applied reinforced aluminium foil as per technical specificatons. Material shall comply to green building standards by using formaldehyde free compound or adhesives with low VOC content of 13mm |
| 147 | Supply, installation, testing and balancing of powder coated Extruded Aluminium supply/return/exhaust air Grilles without volume control dampers in accordance with the approved shop drawings and specifications. |
| 148 | Supply and Installation of Collar Damper |
| 149 | Supply and Installation of VCD |
| 150 | Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC |
| 151 | Supplying, installing, testing and commissioning of 25 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 75 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges for RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG. |
| 152 | Supply of 148mm Dia X 158mm Height 3000K Circular Flood Light with Non-integral driver & completely made in India luminaire. The luminaire’s shall be made of Extruded aluminum housing powder coated in grey. The complete luminaire has IP66 & IK08 protection and it comprises of high purity integrated poly carbonate Lens.The LEDs shall have minimum CRI ≥80 (White LED) & shall have SDCM≤5. The luminaire shall have wattage 24W and shall deliver 1320 lumens. Beam angle of the Luminaire shall be 11 deg .Fixture shall operating temperature range of 0°C to 45°C. Input Voltage Range of 24V DC. The luminaire shall have declared life of 50,000 burning hours at L70.Luminaire and Driver must be made in India with same brand. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. Must submit the NABL accreditation certificate for Luminaire manufacturer along with LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed / engraded on each an every light fixtures. Luminaire and Driver should be Made in India. Luminare, Driver and controller should be with same make. |
| 153 | Supply of Isolated, constant Voltage type240 W LED Driver enclosurein Extruded Aluminium metal enclosure . Driver shall be made in India compatible for RGBW luminaires with silicone potted and IP66 Protected of same make as luminaire. Output voltage of the driver 24Vdc. Driver efficiency should be greater than 85% at full load, THD < 10%, PF > 0.95 with Under and Over Voltage Cutoff Protection and 440V withstand for 8 hours minimum & sould have large operating input voltage range of 140V to 300V AC(nominal rated voltage – 240V) with 5KV internal surge protection. LED driver shall have inbuilt output short circuit, over voltage protection, Thermal Shutdown protection. |
| 154 | Supply of Patch cord Patch Endcap 1m |
| 155 | Supply of 148mm Dia X 158mm Height 3000K Circular Flood Light with Non-integral driver & completely made in India luminaire. The luminaire’s shall be made of Extruded aluminum housing powder coated in grey. The complete luminaire has IP66 & IK08 protection and it comprises of high purity integrated poly carbonate Lens.The LEDs shall have minimum CRI ≥80 (White LED) & shall have SDCM≤5. The luminaire shall have wattage 24W and shall deliver 1320 lumens. Beam angle of the Luminaire shall be 60 deg .Fixture shall operating temperature range of 0°C to 45°C. Input Voltage Range of 24V DC. The luminaire shall have declared life of 50,000 burning hours at L70.Luminaire and Driver must be made in India with same brand. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79.Must submit the NABL accreditation certificate for Luminaire manufacturer along with LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed / engraded on each an every light fixtures. Luminaire and Driver should be Made in India. Luminare, Driver and controller should be with same make. |
| 156 | Supply of 495mm Length X 155 mm Width X 190mm Height 3000K Rectangular Flood Light with Non-integral driver & completely made in India luminaire. The luminaire’s shall be made of Extruded aluminum housing powder coated in grey. The complete luminaire has IP66 & IK08 protection and it comprises of high purity integrated poly carbonate Lens.The LEDs shall have minimum CRI ≥80 (White LED) & shall have SDCM≤5. The luminaire shall have wattage 100W and shall deliver 5500 lumens. Beam angle of the Luminaire shall be 30 deg .Fixture shall operating temperature range of 0°C to 45°C. Input Voltage Range of 24V DC. The luminaire shall have declared life of 50,000 burning hours at L70.Luminaire and Driver must be made in India with same brand. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79.Must submit the NABL accreditation certificate for Luminaire manufacturer along with LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed / engraded on each an every light fixtures. Luminaire and Driver should be Made in India. Luminare, Driver and controller should be with same make. |
| 157 | Supply of Isolated, constant Voltage type150 W LED Driver enclosurein Extruded Aluminium metal enclosure . Driver shall be made in India compatible for RGBW luminaires with silicone potted and IP66 Protected of same make as luminaire. Output voltage of the driver 24Vdc. Driver efficiency should be greater than 85% at full load, THD < 10%, PF > 0.95 with Under and Over Voltage Cutoff Protection and 440V withstand for 8 hours minimum & sould have large operating input voltage range of 150V to 300V AC(nominal rated voltage – 240V) with 5KV internal surge protection. LED driver shall have inbuilt output short circuit, over voltage protection, Thermal Shutdown protection. |
| 158 | Supply of 2 X6W, Wall Up - Down Light 3000K with Integral driver & completely made in India luminaire. The luminaire’s shall be made of Die cast aluminum with Pure polyester powder coated housing. Optical compartment is sealed with toughened glass using Silicon gasket ensuring IP65 & IK06 protection and lifelong performance.The LEDs shall have minimum CRI ≥80 (White LED) & shall have SDCM≤5. The luminaire shall have wattage 2 X 6W and shall deliver 2 X 600 lumens. Beam angle of the Luminaire shall be 20 deg. Fixture shall operating temperature range of 0°C to 45°C. Input Voltage Range of 140 - 280V AC. 2 stage Constant current driver with Inbuilt 3kV surge protection. The luminaire shall have declared life of 50,000 burning hours at L70. Luminaire and Driver must be made in India with same brand. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. Must submit the NABL accreditation certificate for Luminaire manufacturer along with LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed / engraded on each an every light fixtures. Luminaire and Driver should be Made in India. Luminare, Driver and controller should be with same make. |
| 159 | Supply of 100 mm Dia X 175mm Height Recess Down Light 4000K with Integral driver & completely made in India luminaire. The luminaire’s shall be made of Exteruded aluminium powder coated. Optical compartment is sealed with toughened glass using Silicon gasket ensuring IP65 & IK06 protection and lifelong performance.The LEDs shall have minimum CRI ≥70 (White LED) & shall have SDCM≤5. The luminaire shall have wattage 15W and shall deliver 1350 lumens. Beam angle of the Luminaire shall be 60 deg. Fixture shall operating temperature range of 0°C to 45°C. Input Voltage Range of 140 - 280V AC. 2 stage Constant current driver with Inbuilt 3kV surge protection. The luminaire shall have declared life of 50,000 burning hours at L70. Luminaire and Driver must be made in India with same brand. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79.Must submit the NABL accreditation certificate for Luminaire manufacturer along with LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed / engraded on each an every light fixtures. Luminaire and Driver should be Made in India. Luminare, Driver and controller should be with same make. Wipro make - LD08-151-060-40-RM |
| 160 | The 20W COB LED Downlight luminaire shall provide 2000 lumens with a cut-out diameter of 110mm and a height of 72mm, suitable for recess mounting. It will feature a white powder-coated extruded aluminium housing with an inbuilt heat sink for enhanced thermal management, ensuring long LED life. The optical compartment will include a high-efficiency reflector and a PC diffuser to produce a precise light beam while minimizing glare, achieving a Unified Glare Rating (UGR) of less than 15. The luminaire will be equipped with LM 80-08 compliant LEDs from reputed manufacturers like Nichia, Cree, Bridgelux, Lumileds, Osram, Seoul, or Citizen, with a minimum L70 life of 50,000 hours at maximum current, supported by a complete LM 80 test report for 10,000 hours. Additionally, the LEDs will comply with EN 62471 for photobiological safety, and a certificate confirming compliance will be provided. The color temperature will be 3000K, with a minimum Color Rendering Index (CRI) of 80, and the available beam angles will be 24°, 36°, and 60°. The luminaire will feature an integrated, isolated, constant current operated LED driver with a voltage range of 120-270V AC. The driver will have an efficiency greater than 85%, 3 kV internal surge protection, a power factor greater than 0.95, and total harmonic distortion (THD) of less than 15%. The luminaire will be IP20 rated for indoor use. LM 79 and LM 80 reports from a NABL/UL accredited lab will be provided to verify the performance. The product will comply with Indian standards IS 10322 Part 5/Sect 2, IS 16105:2012, IS 16106:2012, IS 15885 (Part 2/Sec 13):2012, and IS 16108:2012. The manufacturer must also have an in-house lab approved by NABL or the Ministry of Science and Technology, Government of India. |
| 161 | Supply of COB Magneto Track Light, IP 20, 24W Track Mounted with System efficacy of , operating in an ambient temperatire of 0⁰C to 45⁰C at 50Hz frequency. Luminaire shall have aluminium pressure die cast housing in Black with hHigh efficiency diffuser . EMC/PCT package of wattage of 0.5-1 W LEDs used in the product shall comply with IEC 62471 for Photo-biological safety. LM 80-08 compliant LEDs from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul should be provided. The LED shall comply with L70 life of 50000 burning hours tested at maximum current. The LEDs used should be with CCT of 4000 K and CRI of Minimum 80, with MacAdam CCT binning <3 mounted on 1.6mm MCPCB/FR4 with 35 micron cu layer. LEDDriver shall be external, Isolated type, Power factor of minimum 0.95, driver efficacy of minimum 85%, and total harmonic distortion (THD) of less than or equal to 10% should be integral to the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance toIndian Standards of IS10322 Part 5 / Sect 5:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012. |
| 162 | MAGNETO RM TRACK FOR TRACK LIGHT: LDX17 2mtr Track |
| 163 | MAGNETO TRACK FIXED JOINTER |
| 164 | SURGE PROTECTION 3 KVA |
| 165 | Supply, erection,testing and commissioning of GI pipe line class \"C\" E.R.W (as per IS:1239 / 3589 along with fittings like sockets, bends, elbows, tees, plugs, nipples, flanges, reducers etc. (APPROX) for above Ground With Painting150 mm dia |
| 166 | Supply, erection,testing and commissioning of GI pipe line class \"C\" E.R.W (as per IS:1239 / 3589 along with fittings like sockets, bends, elbows, tees, plugs, nipples, flanges, reducers etc. (APPROX) for above Ground With Painting80mm dia. |
| 167 | Supply, erection, laying, jointing and testing in trenches the following sizes of GI class `C\" (heavy class) pipes conforming to IS:1239 with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, G.I. nuts, bolts and washers.for Under Ground 150 mm dia |
| 168 | Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.13.6.10 |
| 169 | Supplying and erectingcast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV 150 mm Dia |
| 170 | Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/AR |
| 171 | Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV |
| 172 | Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FFFFA/NZ |
| 173 | Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe,15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL |
| 174 | Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8\" x 6\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) 13.8.19 |
| 175 | Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/FMC |
| 176 | Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG |
| 177 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 178 | Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 1 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity,interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP. |
| 179 | Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with \"Break Glass\" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP. |
| 180 | Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH. |
| 181 | Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300μA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FFAFAS/ SD . |
| 182 | Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5 - 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI |
| 183 | Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area\"s etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD. |
| 184 | Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM |
| 185 | Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU |
| 186 | Supplying, erecting, testing and commissioning 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR |
| 187 | Supplying, erecting, testing and commissioning 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC |
| 188 | Supplying, erecting, testing and commissioning rust free microphone floor stand of chrome plating/powder coating or S.S. material , 500 mm to 1500 mm height and sturdy mechanism ensuring trouble free movement complete. |
| 189 | Supplying, erecting, testing and commissioning of 2 core shielded cablecomplete as per specification no. FF-PA/MCC |
| 190 | Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall. 10-2-36 DSR-21-22 |
| 191 | Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete. |
| 192 | Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats ofsilver paint complete. |
| 193 | Supplying & installing auto glow ( Viewing upto 15 Mtr length) fire Signages viz Fire Hydrant, Fire Extinguishers , Fire Exit , Fire Door . Fire Hqse Box etc. Size of 300 x 100mm |
| 194 | Supplying & installing auto glow ( Viewing upto 15 Mtr length) fire Signages viz Fire Hydrant , Fire Extinguishers , Fire Exit . Fire Door . Fire Hose Box etc. Size of 450 x lsomm |
| 195 | Supplying & installing auto glow ( Viewing upto 15 Mtr length) Iire Signages viz Fire Hydrant , Fire Extinguishers , Fire Exit , Fire Door , Fire Hose Box etc. Size of 600 x 2oomm |
| 196 | Supply & installation of 30 Feet Aluminium Self Support Extension Ladder Comes with corrosion-resistant coating.Skidproof ladder steps. Rubber grips are also provided at the top and the bottom legs of the ladder.Heavy-duty ladder frame.Both sides are assembled with a ladder section. |
| 197 | SITC of 2 D Digital Planetarium System with following detailsComplete Pure RGB Laser Projector Array• Servers & Rack, Console, Show Control Hardware & Software• Astronomy Simulation & Playback Software with Complete features• Auto Alignment, Auto Blending, Auto Geometry Correction, Auto Stitching, Auto Calibration, Auto Uniform Illumination Systems• AMNH – Digital Universe Database• Four 2D Full dome Shows• Two Astronomy Shows• Complete Installation, Integration, Commissioning• Warranty – 2 Yrs• Spare Parts Kit for Computer Rack• All Cables, Connectors (Pease Follow Additional Specification In Tender) |
| 198 | SITC of Seamless Projection Dome Powder Coated15 Mtr dia & 15 deg Tilt• Perforated Al Panels• Cove Trough• Complete Installation & Commissioning• Service Ladder (Pease Follow Additional Specification In Tender) |
| 199 | SITC of Sound System5.1 Surround Sound System & Rack• Amplifiers, Speakers, Mixer, Matrix Switcher, Cordless mics, Equalizer• Installation, Integration & Commissioning (Pease Follow Additional Specification In Tender) |
| 200 | SITC of LED Cove Light SystemIndian Make (Professional) suitable for 15 M dome with all features• Exit and Entry Signage• Seat Row LED lighting (Pease Follow Additional Specification In Tender) |
| 201 | SITC of UPS SystemSuitable online UPS System specially designed for the proposed Planetarium System including audio system, Cove Lighting, Battery Backup, Racks, Cabling, Integrating with 30 minutes of backup (Pease Follow Additional Specification In Tender) |
| 202 | Operation Charges after Completion work with consumable Item Six Months operation charges after completion Work with consumable item & with following Staff Requirment at PlanetariumEngineering Staff1 Sr. Planetarium Operator 2 Assistant Planetarium Operator 3 Air conditioner operator4 Electrical operator5 Technician (Mechanical)6 Technician (Electrical)7 HelperFire Fighting Staff8 Supervisor/Operator9 HelperHousekeeping Staff10 Supervisor/Operator11 HelperSecurity Staff12 Security Persons Day Shift13 Security Persons Night ShiftTicketing Staff14 Cashier/ Cleark |
| 203 | Supply Dry & Wet Vaccume cleaner , 1500 W, Airflow 250 CUM/H, 15 Lit Tank, Cable Length 20 Mtr. |
| 204 | Supply Rodent trap |
| 205 | Supply 100 W LED Flood light with Aluminium hand held of height 2 Mtr & Cable 25 Mtr. |
| 206 | Supply 200 W LED Flood light with Aluminium ladder held of height 10 Mtr, Tripod & 3 Flood lights of 200W Each & Cable 50 Mtr. |
| 207 | Supply Safety helmet along with rechargable toarch arrangement |
| 208 | Supply Rubber Cushion Matt as per requirement upto satisfaction |
| 209 | Supply 15 Ltr bucket made of PVC as per requirement upto satisfaction |
| 210 | Supply Gala mop inlcuding rince roller bucket |
| 211 | Supply Phenyl |
| 212 | Supply Cloths |
| 213 | Supply Brooms |
| 214 | Supply Air diffusers |
| 215 | Supply Sanitizer sprey |
| 216 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge.Note: - (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. |
| 217 | Providingstructuralsteelworkinhollowsectionofvariousthicknessandsizesin square, rectangular and round shape from 25mm to 450mmsection as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete.,SSR-2022-23,Item No.-23.12,Sr. No.-826,Ref(Specification)-Spec. One Number As directed by Engineer in Charge. |
| 218 | Providing and fixing commercial grade 19 mm thick plywood, coated/ coloured from both sides, fixing in position as per detailed designs and drawing or as directed including cutting.hoisting, erecting, fixing in position, making riveted/bolted/ welded connections etc complete. As directed by Engineer in Charge. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy