| 1 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish[PWD Schedule Page No-E-14;2](c)Average run 8 mtr |
| 2 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.2+4 way(Legrand)[PWD Schedule Page No-D-9;Iteam No-13] |
| 3 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection6-32A SP MCB[PWD Schedule Page No-D-6;Iteam No-7] |
| 4 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.63A FP MCB Isolator(Legrand)[PWD Schedule Page No-D-5;Iteam No-6] |
| 5 | Supply of Powder coated Industrial regular Batten for 15W LED 6500 K mounted panel Light with integral LED driver.Make - Havells |
| 6 | Supply & Fixing of Powder coated Batten for T5 28W with replacable Electronic Ballast.(Model-BATTEN EZ T5LHIT81128032)(Make-Havells) |
| 7 | Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling by screws etc.[PWD Schedule Page No-C-2;Iteam No-14a] |
| 8 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works(b) 6 Module[PWD Schedule Page No-E-17, Iteam No-1] |
| 9 | ( e ) 2 Row 12 Module[PWD Schedule Page No-E-17, Iteam No-1] |
| 10 | Supply 1200 mm 3 blade ceiling fan (Make - Cromption/Havells) |
| 11 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.[PWD Schedule Page No-C-3, Iteam No-21(a)] |
| 12 | Supplying and Drawing 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC[PWD Schedule Page No-E-9, Iteam No-1(s)] |
| 13 | 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC[PWD Schedule Page No-E-9, Iteam No-1(v)] |
| 14 | Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI \"U\" hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles[PWD Schedule Page No-E-3, Iteam No-6(b)] |
| 15 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:60 cm (24\")[PWD Schedule Page No-C-4, Iteam No-28(e)] |
| 16 | Supply of Powder coated Industrial regular Batten for 28W LED 6500 K mounted pFlex strip lighgt with integral LED driver.Make - Havells |
| 17 | Supply of 9\" (225mm) SWEEP. TRANS AIR -(Make - Havells/Crompton) |
| 18 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:22.5cm ( 9\" )[PWD Schedule Page No-C-4, Iteam No-28(a)] |
| 19 | Fixing only louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long)For (9\") Exhaust fan[PWD Schedule Page No-C-4, Iteam No-30(a)] |
| 20 | Supplying of 1.1 KV. Grade PVC insulated Conductor of following cables (make: Polycab/ Gloster/Havells/)10 sqmm 4 core alluminium[Ref. UD & MA Electrical-Mechanical Works (Volume-1), Page No - 11/ Item(c)-3] |
| 21 | Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish(i) From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.[Ref. PWD Electrical Shedule 2017, Page No - F-3/ Item5] |
| 22 | Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.[Ref. PWD Electrical Shedule 2017, Page No - E-19/ Item17] |
| 23 | ADD 18 % GST |
| 24 | ADD 1% CESS |