| 1 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof coverings Complete all as specified and as directed by Engr-in-charge. |
| 2 | M & L for prepainted galvanume aluminium zine coating GI based corrugated steel sheeting 0.50 mm thick any colour having tensile strenght 550Mpa in roof coverings fixed with self tapping screws Complete all as specified and as directed by Engr-in-charge. |
| 3 | M & L for prepainted galvanume aluminium zine coating GI based plain steel sheeting 0.50 mm thick any colour having tensile strenght 550Mpa in roof coverings fixed with self tapping screws Complete all as specified and as directed by Engr-in-charge. |
| 4 | Dismantling of wall andceiling boards(fibre, pulp, insulationetc.) or insulation boards/ slabs/ blankets, any thickness including cover filletsComplete all as specified and as directed . |
| 5 | S&F hangers 6mm dia G.I. (upto 1200mm length ) adjusting level, size of grid 605mm X605mm, fixed to steel purlins or rafter with nexc 60cm long and 6mm dia adjustable GI fasternersComplete all as specified and as directed by Engr-in-charge. |
| 6 | S&F Gl frame work for seamlessceiling comprising of GIperimeter channnel 0.55 mmthick with two unequal flangesof 20 and 30 mm and web of27 mm fixed to surrounding wall using nylon sleeves andscrews at 450 mm centre tocentre /intermediate channel 0.9 mm thickhaving two equalflanges of 15 mm each and webof 45 mm suspended fromsoffit at approx 900 mm centreto centre with Gl cleatetc as in false ceiling frame workComplete all as specified and as directed by Engr-in-charge. |
| 7 | S&F Non asbestos fiber cement building board(Designer board) 6mm thick , fixed to aluminium or MS galvanised snap grid frame work with screw in ceiling Complete all as specified and as directed by Engr-in-charge. |
| 8 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified. |
| 9 | Supply and fix steel work in tubular trusses/rafter/purline including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240 complete all as specified and as directed. |
| 10 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc complete all as specified and directed. |
| 11 | M&L for Precast cement concrete 1:3:6 type C1 (Using 20 mm graded crushed stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed. |
| 12 | Taking down cement plaster any description from roof slab, stone wall, brick wall parapets including raking out joints hacking for key and scrubbing down with water etc(for roof treatment) complete all as specified and as directed by Engr-in-charge. |
| 13 | M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finish the surface even and smooth without using extra cementall as specified and as directed by Engineer-In-Charge. |
| 14 | M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even andsmooth without using extra cement complete all as specified. |
| 15 | M&L for Preparing new plastered surfaces and applying two coats of cement base paint on surfaces of walls over one coat of alkali resistant primer complete all as specified and as directed by Engr-in-charge. |
| 16 | M & L forold decorative surfaces, preparation of wall and applying two coats of cement base paint complete all as specified and as directed by Engr-in-charge. |
| 17 | M&L for prepair old decorative surface and applying two coats of oil bound distemper on walls etc Complete all as specified and as directed by Engr-in-charge. |
| 18 | M&L preparing newly plastered surfaces of wall and applying complete walland applying two coats of Oil bound distemper over a coat of primer all as specified and directed . |
| 19 | Taking out old unserviceable floor, hearth or wall tiling including cement mortar bedding (but not backing and rubbish off the premises complete all as specified and as directed |
| 20 | M & L for glazed ceramic colourtiles 300x 450x 7mm as in vertical surface of wall etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over backing coat 10mm thick in CM 1:4complete all as specified and as directed. |
| 21 | M&L 15mm thick screed bed or bedding layer in cement plaster 1:4 for laying floor finished to receive floor tiles/granite complete all as specified and directed by engr in charge. |
| 22 | S&F Coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but notexceeding 0.38 sqm, in floors etc, setand jointed in neat cement slurry and pointed in white or Coloured cement to match shade of the tiles complete all as specified & directed. |
| 23 | Demolition ofcement concrete in ground floors and pavings not exceeding 15 cm thickness. (Below or above ground level) complete all as specified and directed by engr in charge. |
| 24 | M&L 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm gradedstone aggregate) in plinth protections, finished even and smooth w/o using extra cementincluding necessary joints |
| 25 | M&L for 100mm thick cement concrete 1:2:4 type B2 using (40 mm graded stone aggregate)and laid in alternate bays as inhard standing & finished the surface even & fair without using extra cement all as specified. |
| 26 | Forming Construction joint 30mm deep x10mm wide including filledwith sealing compound(1x part of bitumen and 3 x part of sand) and complete all as specified and directed. |
| 27 | Taking down Chowkats or frames not exceeding 1.5 Sqm each (Without taking off shutters from the frames) complete all as specified and directed. |
| 28 | Taking down chowkats or frames exc 1.5 sqm but not exceeding 4 sqm each but with shutter (without taking off shutter from the frame) and removing to store complete all as specified and directed by Engr-in-charge. |
| 29 | S&F factory made pressed steel frames 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.,complete all as specified and directed by engr in charge. |
| 30 | M&L Plain Cement Concrete1:3:6 type C1 filling of pressed steel frame and hold fast block etc. complete all as specified and directed by engr in charge. |
| 31 | S&F 2nd class hardwoodfactory made 30 mm thick flushshutter solid core construction with block board core & plywood face panels commercial type on both sides incl 5mm thick teakwood leaping alround complete all as specified & directed. |
| 32 | Supply and fixing (factory Made)2nd class hard wood35 mm thick glazed and skelton shutters open rebated and prepared to receive gauge.(Without sash bars) edges of framing plain chamfered or rounded fittedwith cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I section 8 clause 8.20 (a) supplied and fitted to chowkatscompleteall as specified. |
| 33 | M&LAluminium anodised, barrel tower bolts of extruded section and fixed of size 200 mm complete all as specified and as directed by Engr-in-charge. |
| 34 | S&F 150 mm long aluminium anodised handles or extruded section complete all as specified and directed. |
| 35 | S&F 300mm long Aluninium alloy, anodised , sliding door bolt with hasp , staple,(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. |
| 36 | S&F Mild steel 300mm ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 37 | S&F floordoor stopper 140 mm of aluminium alloy body and tongue anodised with hard drawn steel springcomplete all as directed by Engineer-in-charge. |
| 38 | Supply & fixing for galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm & fixed with tinned tacks, or galvanised wire staples. & directed by Engr-in-charge. |
| 39 | Supply and fixed steel windows with side hungshutters including box type hinges with steel handle and steel peg stay complete with glazing bars for glazed shutters, dovetailed or welded complete all as directed by Engineer-in-charge. |
| 40 | Supply and fixedsteel ventilatorfor industrial buildings fixed type with glazing bars, complete with glazing bars for glazed shutters, dovetailed or welded complete all as directed. |
| 41 | S&F plain sheet glass of 4 mm thick in Squares not exceeding 0.50 Sqm in each pane with oil putty and clips complete all as directed by Engineer-in-Charge. |
| 42 | Dismantling structural steel work including doors,gates but excluding framed truss etc.complete all as specified and as directed. |
| 43 | Supply and fixed Steel rolling shutters, with outball bearing, as specifiedincluding top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete:push pull ormanual type in position as indicated complete all as specified and directed. |
| 44 | Supply and fixed safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed. |
| 45 | M & L for preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat synthetic enamel paintcomplete all as specified and directed by Engr-in-charge. |
| 46 | Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 47 | M&L reinforced cement concrete (nominal mix) type A1 1:1.5:3 (20mm graded aggregate)asincolumns, pillars, piers,posts and struts , all as specified and directed. |
| 48 | Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished concrete surfaces complete all as specified and as directed. |
| 49 | Material andlabour for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending lapping etc as required and welding with existing bar complete all as specified and as directed |
| 50 | All as per Item No. 49 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders. |
| 51 | Material and labour for 5mm thick plastering in CM (1:3) on concrete surfaces as in sides of column, lintel, beam, chajja, faciaetc including finish the surface even and fair without using extra cement complete all as specified and as directed |
| 52 | Material and labour for framed work as in steel doors of gates of angles or other section with gusset plates, rails, braces, etc. Complete,conforming to Fe-410W (Gde-E-250) quality \"B\", drilled for fixing of steel sheeting or other covering. doors etc to be prepared hanging or sliding with and including either hooks and hinges or steelhangingdoor fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing complete all as spd & directed. |
| 53 | Material and labour for mild steel, plain, black sheet 1.60mm thick in steel gates, wall cladding and similar works, cut to size, holes punched, includinground headed screws clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams including bending or turining up, mitred angles etc, as required complete all as spd & directed. |
| 54 | Preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engr-in-charge. |
| 55 | Ditto- all as per item 54 above but one coat of synthetic enamel paint on old steel surfaces of any description complete all as spd & directed. |
| 56 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, excluding fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed by Engr in Charge. |
| 57 | Taking down unserviceable submain wiring and service cable alongwith batten/ PVC conduits etc. and making good disturbed surfaces of walls/ floors and match the existing surface complete all as specified & directed by Engr in Charge |
| 58 | Taking down unserviceable main switches, DBs with MCB SP/ Isolators by unscrewing form board complete all as specified & directed by Engr in Charge |
| 59 | M&L for point wiring using approved colour coding as per IS with using approved colour coding as per IS 1.5 Sqmm multistranded,1100 volt grade copper conductor cable of PVC insulated and unsheathed type alongwith 1.5 Sqmm PVC insulatedstranded copper conductor cable for continuous earthing in & incl PVC Casing and capingwith accessories having ISI mark fixed on wall surfaces / ceilingincluding provision PVC Box on top for fixing switches sockets etc. all as specified for one light point/ fan /Bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge. |
| 60 | All as per Srl item No 59 here-in-before but controlled with one 5 pin socket outlet 5 Amp on same board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge. |
| 61 | All as per Srl item No 59 here-in-before but controlled with one 5 pin socket outlet 5 Amp onthe independent board with other switches with cables 1.5 Sqmm including provision of 1.5 sqmm single core multistanded PVC insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge. |
| 62 | All as per Srl item No 59 here-in-before but controlled with one 5 pin socket outlet 15 Amp, independent board withcable 2.5 sqmm including provision of 2.5 sqmm single core multistanded PVC insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge. |
| 63 | Supply and fixing of piano type switch 15 amp, 230 volt, flush button single pole one way complete all as per specified and directed by Engineer-in-Charge. |
| 64 | Supply & fixing of socket outlet 3 pin 15 amp 2-in-1 230 volt flush type complete all as per specified and directed by Engineer-in-Charge. |
| 65 | Supply & fixing of socket outlet 3 pin 5 amp 2-in-1 230 volt flush type complete all as per specified and directed by Engineer-in-Charge. |
| 66 | Supply & fixing of switch piano type 5 amp, 230 volt, flush button single pole one way complete all as per specified and directed by Engineer-in-Charge. |
| 67 | Supply and fix ceiling fans, complete with three blade, down rod, accessoried 230V, 1200 mm sweep, with squirrel cage induction motor complete all as per specified and directed by Engineer-in-Charge. |
| 68 | M&L Ceiling rose, 3 terminal with ISI markall as specified and directed by Engr-In-Charge. |
| 69 | Supply andfixing surface & wall mounted LED 20W (Warm white) tube light fitting batten 4 feet, mirrorlite slim type with extruded aluminium housing enhances safety. High quality PC diffuser, reliable and robust housing structure, maximize the endurance over thelifetime slim integrated design, easy to install efficacy 125 limen/ watt all accessories complete all as specified and directed by Engr in Charge. |
| 70 | Material and labour forlamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engr in Charge. |
| 71 | S&F LED lamp 9W energy saving upto 80%, BEE rated with all accessories complete all as specified and directed by Engr in Charge. |
| 72 | S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as specified and directed by Engr in Charge. |
| 73 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMS diffuser soft glare free light comoplete with driverm holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr in Charge. |
| 74 | S&F bulk head light with 10 W LED Lamp complete all as specified and directed by Engr in Charge. |
| 75 | Supply and fixing of sheet metal enclosure double door for DBs single pole and neutral for 12 way 240 volt complete all as specified and directed by Engineer-in-Charge. |
| 76 | S&F MCBSPN 63 Amp,10 KA, complete all as specified and directed by Engineer-in-Charge. |
| 77 | S&F MCBSPN 16 Amp,10 KA, complete all as specified and directed by Engineer-in-Charge. |
| 78 | S&F in replacement of ON LOAD change over switch 415 V in sheet metal enclosures 4 pole of capacity 63 amps complete all as specified and directed by Engineer-in-Charge. |
| 79 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanised earth wire of 4 mm dia by means of bolts, nuts hook nuts and washers of galvanization of steel all as shown in electrical plate no 3 connected to earthing testing point all as specified or indicated including testing of completions.. |
| 80 | S&F for steel body exhaust fan AC, single phase 230/240V of 450 mm sweep 1400 rpmincluding louvre & cutting of holes in a round shape and including fixing the exhaust fan complete all as specified and directed.Note:- Fixing of Exhaust fan on wall with suitable size anchor bolt, making hole in wall for grouting and making good the disturbed surface including plaster work shall be part of job at no extra cost. |
| 81 | M & L in replacement of Earthing complete with galvanised steel earth plate electrode 600×600×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead strip 24x4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion all as directed. |
| 82 | S&F Modular Metal flush box 1/2 module complete all as specified and directed by Engineer-in-Charge. |
| 83 | S&F Modular Metal Metal flush box 3 module complete all as specified and directed by Engineer-in-Charge. |
| 84 | S&F Modular Switch socket combination 16A, 6 pin, 3 module complete all as specified and directed by Engineer-in-Charge. |
| 85 | S&F Modular Switch socket outlet 5 pin 6A flush type complete all as specified and directed by Engineer-in-Charge. |
| 86 | Supply & fixing 1100 volts grade heavy duty, XLPE aluminium cable, in service connections, twin core 10 Sqmm Circural cable, complete all as specified and directed by Engr in Charge. |
| 87 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in hard/ dense soil for laying/ jointing kit/ repair of cable and erection of poles complete all as specified and directed by Engr in Charge. |
| 88 | Returning filling in including spreading, leveling watering and well ramming in layers n.exc 25 cm in hard/ dense soil complete all as specified and directed by Engr in Charge. |
| 89 | Removing excavated material n.exc 50 mts and depositing where directed at a level n.exc 1.5 mt above the starting point complete all as specified and directed by Engr in Charge. |
| 90 | M&L for taking out old unserviceable and supply, laying, fixing double walled corrugated HDPE duct pipeof 25 mm outer dia confirming to IS-14930 (Part-II) of approved colour with fittings for cable protection complete all as specified and directed by Engr in Charge. |
| 91 | M&L in replacement of Submain wiring with two run of 4.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and incl in PVC casing caping/ PVC conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistrandedcopper conductor cable of size 4 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly.(Note: Industrial socket shall be measured & paid under separate item) |
| 92 | Taking down shutters of any description not exceeding 1.0 Sqm each complete all as specified and as directed. |
| 93 | M&L for walling of random rubble masonry uncourced well bonded bedded and solidly hearted built in CM 1:6complete all as specified and directed by Engr-in-Charge. |
| 94 | M & L for providing precast cement concrete type C-1, 1:3:6 using 20mm graded stone aggregate and set in cement mortar 1:6 as bond stone complete all as specified . |
| 95 | M & L for Raised pointing to random or polygonal rubble, uncoursed or brought upto courses in cement mortar 1:3 complete all as specified and directed. |
| 96 | Material and Labour PCC 1:3:6 Type C1(using 20 mm graded stone aggregate) as in bed block , coping , kerbs, rounded or chamfered on edge including necessary form work complete all as specified and as directed . |
| 97 | S&F Coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but notexceeding 0.38 sqm, in Skirting etc, setand jointed in neat cement slurry and pointed in white or Coloured cement to match over backing coat 10mm thick in CM 1:4 complete all as specified & directed. |
| 98 | M&L for 75 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing & finished the surface even & fair all as specified. |
| 99 | M&L for Chequered cement concrete tiles 300x 300x 25mm thick with grey cement and pigment set and jointed in neat cement slurry and pointed in white or coloured cement incl 15mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and directed by Engr-in-charge. |
| 100 | M & L for providing cement concrete cas in situ 1:2:4, type B1 (using 20mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edge including use of formwork complete all as specified and directed by engr in charge. |
| 101 | Supply and fix 35mm thick 2nd class hard wood factory made plain framed panelled door shutters, (two panel) with lock rail and panel of 12mm veneered particle board with commercial veneered on both faces and rail and stiles as per IS 1003(Pt-I), kilnseasoned and chemically pressure treated etc. complete all as specified and as directed. |
| 102 | Supply and fix 30mm thick factory made 2nd class hard wood glazed and skeletonwindow shutters, open rebated and prepared to received glass/gauge etc (with sash bars) divided in squares with plain, chamfered or rounded and mitred, and rebated sash bar any number for securing glass etc the size of member of shutter as specified in SSR Part-I, clause 8.24 (b) complete all as specified and as directed. |
| 103 | M & L for Preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer. |
| 104 | S & F Mild steel butt hinges medium weight , cold rolled, 100mm, ISI marked, complete all as specified and as directed by Engr-in-charge. |
| 105 | Supply and fix 75 mm size butt hinges, medium weight, cold rolled mild steel ((ISI marked) complete all as specified and as directed. |
| 106 | Supply and fix 100mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed. |
| 107 | Supply and fix 100mm size extruded aluminum alloy handle fabricated type anodized (ISI Marked) complete all as specified and as directed. |
| 108 | S&F in repair20mm dia curtain rods fancy type, mild steel chromium plated with fixing brackets, stops, rollers complete all as specified and as directed. |
| 109 | Material and labour for applying one coat of synthetic enamal paint to wooden surface as in ceilinig surface exceeding 10cm widht or girth complete all as specified and as directed. |
| 110 | Schedule of Credit |