| 1 | SMART PERIODICALM&L for complete removal of existing treatment of walls by mechanical means complete all as specified and directed.Note : Work will be strictly executed by mechanical means/tools as required for smart periodical services). |
| 2 | M&L for applying 2mm thick wall care putty (of approved make) making smooth surface complete all as specified and directed. |
| 3 | M & L for applying Two or more coats of 100% Premium acrylic emulsion paint (weather proof)having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shadewith silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on smooth surface of walls complete all as specified and directed.Note : For serial item Nos 1 ,2 ,3 and 17(a.) The work pertaining to periodical services shall be executed from authorized applicator through manufacturer of which the materials .i.e. Paint, Distemper, Cement base paint, Putty etc. to be used by the contractor and approved by Garrison Engineer.(b.)The contractor shall upload along with the documents under cover-I, ‘Memorandum of Understanding’ (MOU) with only one manufacturer mentioned in the contract, failing which the bid shall be liable to be rejected. (c) Work will be strictly executed by mechnised means/tools as required for smart periodical services i.e. vacuum based sanding machine,mechanical mixer,grinder, roller etc.(d) The rate quoted by contractor is deemed to be included necessary steel/wooden scafolding and from work as required upto 12m height building. |
| 4 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 5 | M&L forbrick work with fly ash bricks old size, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed. |
| 6 | As as described Ser item No. 5 here-in-before but except brick ( sub class \"B\" bricks or fly ash bricks which is retrieved from demolition ) complete all as specified and directed. |
| 7 | Taking down cement plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete as directed and specified.Note : The rate quoted by contractor is deemed to be included necessary steel/wooden scafolding and from work as required upto 12m height of building. |
| 8 | M&L applying 15mm thick in CM 1:4 rendering using ready mix plaster mixture on brick/concrete suface of extenal wall finished even and faircomplete all as specified and directedNote : 1. Contractor is required to deposit ready mix bags for 100% CA quanitity within 15 days to AGE B/R-II office after issue of work order. 2. The rate quoted by contractor is deemed to be included necessary steel/wooden scafolding and from work as required upto 12m height building. |
| 9 | M&L 5mm thick rendering on concrete surface of ceiling with cement mortar (1:3) finished even and smooth without using extra cement complete all as specified anddirected. |
| 10 | M&L including preparation of newly plastered surface of ceiling and applying three coats of white wash complete all as specified and directed. |
| 11 | M&L for preparation old plastered/unplastered/decorated surfaces of walls and applying two coat of exterior acrylic emulsion paint including repair of patches with putty and primer complete all as specified and directed. |
| 12 | M&L for preparing old plastered/unplastered/decorated surfaces of walls and applying two coat of cement base paint, complete all as specified and directed. |
| 13 | M&L for preparing surfaces plastered or unplastered old decorated surfaces of ceiling and applying two coats of white wash on ceiling complete all as specified and directed. |
| 14 | M&L for preparing surfaces plastered or unplastered old decorated surfaces of walls and applying two coat of white wash, complete all as specified and directed. |
| 15 | M&L preparation of newly plaster surface and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified and directed |
| 16 | M&L for preparation of old decorated surfaces of walls, washing rubbing down and stooping of distempered and painted surfaces and applying two coat of oil bound distemper using roller for paintingover including repair of patches with putty and primercomplete all as specified and as directed. |
| 17 | M&L applying two coats of oil bound distemper on smooth surface of walls using roller for painting complete all as specified and as directed. |
| 18 | M&L for applying washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified including forming/rpovinding groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster in each Sqm area as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete all as specified and directed. |
| 19 | M&L for clean the surface using wire brush, remove existing paint wall putty and remove the entire loose particles from the dampness surfaces of walls and apply Dampguard solution mixed with wall care putty and apply two coats of mixed solution as per manufacturer instruction complete all as specified and directed.Note : (i) Work will be strictly executed as per manufacturer instruction or as per direction of Engr-in-Charge. |
| 20 | M&L preparation of old wooden surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 21 | M&L prepration of old steel surfaces of any description not otherwise described over 10cm in width or girth and applying two coat of synthetic enamelcomplete all as specified and directed. |
| 22 | Hacking out old broken glass any size thickness from steel frame including removing MS cleats punching or drilling out old glazing pins/springs etc complete all as specified and directed. |
| 23 | S&F 3mm thick sheet glass, ordinary quality glazing with oil putty or fixed with wooden beads in square n exc 0.50 sqm each pane complete all as specified and directed. |
| 24 | S&F in repairs Galvanised mild steel wire cloth, 0.63 mm nominal dia. of wire and avg width of aperture 1.14 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 25 | Cleaning of water tanks of capacity exceeding 500 litre and not exceeding 1000 litre by removing all scale and dirt, etc from tanks and from mouth of circulating pipes etc complete all as specified and directed. |
| 26 | Taking up or down steel tubing and connection 15 mm bore pipe complete all as specified and directed. |
| 27 | S&F tubes medium grade, galvanised with all fittings and fixed complete to walls and ceiling or laid in floors for 15 mm borecomplete all as specified and directed. |
| 28 | S&F in repairs Rotational moulded polythene water storage tanks (Cylinderical vertical with closed top) hoisted and fixed in position 500 ltrs, including 20 mm bore Ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed and dismantling of old water tank complete all as specified and directed. |
| 29 | Taking down eaves gutters and rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed |
| 30 | S&Fin repairs 75mm bore PVC (SWR) pipes in any length with rubber ring joints fixed to walls including clamps complete all as specified and directed. |
| 31 | S&Fin repairs 110mm bore PVC (SWR) pipes in any length with rubber ring joints fixed to walls including clamps complete all as specified and directed. |
| 32 | S&F in repairs 75mm borePVC (SWR) bends any radius complete all as specified and directed. |
| 33 | S&F in repairs 110mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 34 | S&F in repairs 110mm bore PVC (SWR) Tee any radius complete all as specified and directed. |
| 35 | S&F in repairs 75mm borePVC (SWR) Tee any radius complete all as specified and directed. |
| 36 | M&L for cutting and removing of bushes, small trees, vegetation (Peepal, bad small plants etc) of any ida and girth from roof projection, chajjas, wall junction, parapet etc at any height by necessary demolition of brick work, cement plaster, digging out roots from concrete or brick wall filling holes on building wall/roof/chhajja/water tank staging area etc and making good with cement mortar 1:4 complete all as specified and directed. |
| 37 | M&L writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high complete all as specified and directed. |
| 38 | M&L for guniting of spalled / corroded reinforced cement concrete surface, on vertical or overhead position, comprise of chipping of spalled and loose concrete; cleaning rust from reinforcement by sand blasting; scrubbing down concrete surface with wire brushes; cleaning with water; allowed to dry and applying a layer of zinc rich epoxy primer as anti rust on all exposed reinforcement followed by a layer of bonding coat of approved epoxy adhesive on complete exposed surfaces of concrete to be gunited;applying two layers of guniting over steel welded wire mesh having 4 mm dia of wire and aperture 75 mm, total thickness of gunite not exc 25 mm thick (average thickness) in cement mortar 1:2 using OPC 53 grade cement duly mixed with polycrete admixture @ 2% by weight of cement or as per manufactures instruction and finally applying cement plaster over gunite surface of required thickness to give even uniform & smooth finish conforming to proper geometrics in cement mortar (1:3) to match with the existing surface as in sides and soffits etc of slabs, chajjas, fins, fascias, parapets, lintels, columns and beams etc with and incl necessary scaffolding, shuttering, chases to brick work or RCC members etc,complete all as specified and directed. |