| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.all kinds of soil |
| 2 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level: |
| 4 | i) 1:3:6 ( 1 Cement: 3 fine sand : 6 gradedwell burnt brick aggregate 20mm nominal size) |
| 5 | ii) 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size) |
| 6 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level: 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size) |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses,plinth and skirting courses, fillets, columns, pillars,piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) col of boundary- above cover drain, |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies,shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-RCC work in beams, lintels, bands, plain window sills,staircases and spiral staircases excluding precast spiral staircase.1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)forslab- |
| 9 | Centering shuttering including struttings, propping etc.and removal of form work for:i)Columns, Pillars, Piers, Abutments, Posts and Struts with wooden plank |
| 10 | ii) Lintels, beams, plinth beams, girders, bressumers and cantilevers with wooden plank forslab- |
| 11 | iii) Suspended floors, roofs, landings, balconies and access platform with timber planks |
| 12 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars/ Cold twisted deformed steel bars |
| 13 | First class brick work in foundation and plinth including cost of all materials as required complete:-In Cement mortar 1:4 ( 1 cement : 4 fine sand) |
| 14 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:- |
| 15 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position : Karai Wood |
| 16 | Providing wood work in frames of false ceiling,partitions etc. sawn and put up in position : Soft Wood |
| 17 | Providing and fixing wooden moulded beading todoor and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : local Teak Wood |
| 18 | Providing and fixing panelled / or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked bright finished / blacke namelled M.S butt hinges with necessary screws excluding panelling and or glazing, which will be paid for separately but including the wooden beading of 20 × 12 mm for fixing panelling and or glazing as per direction of Engineer-In-Charge. GamairWood35 mm thick shuttersDoor, |
| 19 | Providing and fixing glazed shutters for doors,windows and clerestory windows using 4 mm thick float glass (weight not less than 10ks/Sqm) panes including black enamelled ISI marked MS butt hinges with necessary screws.Gamair Wood35 mm thick shuttersWindow |
| 20 | Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete:25 mm dia |
| 21 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x16 mm |
| 22 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : i) 200x10 mm |
| 23 | ii) 150x10 mm |
| 24 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 100 mm |
| 25 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.Fixed to openings /wooden frames with rawl plugs screws etc. |
| 26 | Providing and fixing ISI marked flush door shuttersconforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veeners on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 27 | Providing and fixing 25 mm thick shutters for cupboards etc. including ISl marked black enamelled M.S. butt hinges with necessary screws :Panelled or panelled and glazed shutters Gamair Wood |
| 28 | Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71mm width & 28mm thick as vertical & horizontal styles. Joints are made using solvent adhesive and GI ‘C sections (39mm x 19mm x 0.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric ‘L’ corners .The panel shall be filled with 3mm thick high - pressure compact laminate as per manufacturer’s specifications and directions of the Engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter). |
| 29 | Providing and fixing factory made door frame (single rebate) made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 60mm width & 30mm thickness and shall be fixed to wall as per instructions of Engineer-In-Charge using 100x8 sheet metal CSK screws. |
| 30 | Providing and fixing hard drawn steel wire fabric 75 x 25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62 x 19 mm beading of Gamair wood. |
| 31 | Providing 40 × 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30 × 10 × 15 cm 1:3:6 mix (1 cement : 3 fine sand : 6 graded stone aggregate 20mm nominal size) |
| 32 | Fixing chowkhats in existing opening includingembedding chowkhats in floors or walls, cuttingmasonry / RCC / CC for hold fasts, embedding hold fasts in cement concrete blocks with cement concrete 1 : 3 : 6 ( 1 cement : 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size ) painting two coats of coal tar to sides of chowkhats and making good the damages to walls and floors as required including disposal of rubbish to the dumping ground with all leads and lifts complete as per direction of the Engineer in charge:-Door Chowkhats, |
| 33 | Window Chowkhats |
| 34 | Providing and fixing aluminium work for doors,windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred andjointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction of Engineerincharge. (Glazing and paneling and dash fasteners to be paid for separately) :-For fixed portion of approved quality:-Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). size (65mmx40mm) |
| 35 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing fittings wherever required including the cost of EPDM rubber / neoprene gasket required ( Fittings shall be paid for separately ):-Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 36 | Providing and fixing glazing of approved quality inaluminium doors, windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) :-With float glass panes of 4.0 mm thickness ( weight not less than 10.0 kg / sqm ) |
| 37 | Providing and laying 1st class quality ceramic floor tiles in different sizes (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 - 2017 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid over 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. all complete as per direction of the Engineer in-charge.Mat Finish Tiles/ Anti-skid Tiles/ Glossy Tiles 300 mm x 300 mm in all shades and designs |
| 38 | Providing and fixing 1st class quality ceramic glazed wall tiles conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-incharge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade etc. all complete as per direction of the Engineer in-charge. 450 mm X 300 mm in all shades and design |
| 39 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 - 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge.. Double charged Stainfree vitrified tiles (Glossy) |
| 40 | Providing and fixing Precast chequered cement concrete tiles 18 mm thick, laid in footpath & courtyard, on 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry including rubbing and cleaning etc. all complete as per direction of Engineer-in-charge. |
| 41 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides |
| 42 | Supply & installation of pre-painted Galvalume sheets for roofing/cladding (size, shape and pitch of corrugation as approved by Engineer-in-charge) in 550mpa steel grade, made out of Cold Rolled Steel coated with Zinc-Aluminium alloy coating of 43.5% Zn, 55% Al and 1.5% Silicon confirming to ASTM A792/A792M and AS1397, Alloy coating AZ150/AZ70, colour coated with high quality Polyester coating, top coated of modified polyester of 20 micron, back side coat of 5 micron, having epoxy primer coat of 5 micron on both side. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in singlelength upto 12 metre or as desired by Engineer-incharge.The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55mm) with EPDM washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required and as per direction of Engineer-in-charge. 0.50mm thickness |
| 43 | Providing and fixing plain Multipurpose Cement board (High Pressure steam cured) as per IS : 14862 : 2000 with suitable screws for fibre cement board in ceiling etc. complete (frame work to be paid separately) : 6 mm thick cement board |
| 44 | Steel work in built up tubular (round, square orrectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes40 mm dia MS pipe |
| 45 | ProvidingandfixingonwallfaceunplasticisedRigidPVCrainwater pipes (working pressure 4 kg / cm2)conformingto IS : 13592 Type Aincludingjointingwith sealring conformingtoIS:5382leaving10mmgapforthermalexpansion:Single socketedSingle socketed pipe -75 mm OD |
| 46 | Single socketed pipe - 110 mm OD |
| 47 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type-A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge :Single equal tee without door110x110x110mm |
| 48 | Single equal tee with door110x110x110mm |
| 49 | Bend 87.5° 110mm |
| 50 | 12 mm cement plaster of mix a) In cement mortar 1 : 4 ( 1 cement : 4 fine sand ) |
| 51 | Neat cement punning. |
| 52 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.For too small damaged portion , |
| 53 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :New work ( two or more coats) over and including water thinnable priming coat with cement primer |
| 54 | Finishing walls with acrylic smooth exterior paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : New work ( two or more coats applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 55 | Applying priming coat [Payment shall be made after submission of Test Certificate issued by theManufacturer] : With ready mixed Pink or Grey primer of approved brand and manufacture on wood work ( hard & soft wood ). |
| 56 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: |
| 57 | Painting with synthetic enamel paint ( one or more coats ) of required colour of approved brand and manufacture on old work to give an even shade including preparation of surface as required complete as per direction of the Engineer in charge. |
| 58 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:Float glass panes of thickness 4 mm Sqm. |
| 59 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 60 | Distempering with 1st quality washable acrylicdistemper of approved brand and manufacture and of required shade on old work ( one or more coats ), to give an even shade as required complete as perdirection of the Engineer in charge. |
| 61 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 62 | Finishing walls with acrylic smooth exterior paint of required shade of approved brand and manufacture on old work ( one or more coats ) including preparation of surface as required complete as per direction of the Engineer in charge. |
| 63 | Varnishing with varnish ( one or more coats of glue sizing ) of approved brand and manufacture on old work including preparation of surface as required complete as per direction of the Engineer in charge:- With copal varnish. |
| 64 | Repairs to plaster of thickness 12 mm to 20 mm inpatches of area 2.5 sqm and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground with all leads and lifts including finishing even and smooth and curing complete as per direction of the Engineer in charge:-With cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 65 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials including malba all complete as per directions of Engineer-in-Charge |
| 66 | Dismantling of flushing cistern of all types(C.I./PVC/Vitrious China) including stacking ofuseful materials near the site and disposal ofunserviceable materials within 50 metres lead. |
| 67 | Dismantling doors, windows and clerestory windows ( steel or wood ) shutter including chowkhats,architrave,holdfasts etc. complete & stacking within 50m lead. a) Of area 3 sqm and below. |
| 68 | Dismantling old plaster or pointing, raking out joints, cleaning and preparing the surface for re-plastering or re-pointing including disposal of rubbish to the dumping ground with all leads and lifts etc.complete as per direction of the Engineer- in-charge. |
| 69 | Dismantling old glass panes from wooden/steel structures including stacking of serviceable materials and disposal of rubbish and unserviceable materials to the dumping ground with all leads and lifts etc.complete as per direction of the Engineer- in-charge. |
| 70 | Demolishing cement concrete manually / bymechanical means including disposal of materialwith all lifts and upto 50 m lead etc. complete as per direction of the Engineer- in-charge:- Nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) |
| 71 | Dismantling tile work in floors and roofs laid incement mortar including stacking material within 50metres lead. |
| 72 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :White Vitreous china Orrisa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 73 | Providing and fixing white vitreous china pedestaltype water closet (European type W.C. pan) with seatand lid, 10 litre low level white P.V.C. flushingcistern with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 74 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 75 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps. |
| 76 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour.a) 450mm long towel rail with total length of 495mm, 78mm wide and effective height of 88mm, weighing not less than 170gms. |
| 77 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/ cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement: 2 coarse sand : 4graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. : For 100 mm dia. Pipe |
| 78 | For 75 mm dia. Pipe |
| 79 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia |
| 80 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 81 | Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 82 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893115 mm nominal bore |
| 83 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):c) 40 mm nominal bore |
| 84 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 85 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall15 mm nominal outer dia .Pipes. |
| 86 | 20 mm nominal outer dia .Pipes. |
| 87 | 25 mm nominal outer dia .Pipes. |
| 88 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete as per CPWD specification and direction of the Engineer - in - charge.(New work) 20 mm nominal bore |
| 89 | 25 mm nominal bore |
| 90 | 40 mm nominal bore |
| 91 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore. |
| 92 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 93 | Providing and fixing ball valve (brass) of approvedquality High or low pressure, with plastic floatscomplete :i) 20 mm nominal bore |
| 94 | ii) 25 mm nominal bore |
| 95 | Constructing brick masonry chamber forunderground C.I. inspection chamber andbends with 1st class bricks in cement mortar1:4 (1 cement : 4 fine sand) C.I. cover withframe (light duty) 455x610 mm internaldimensions, total weight of cover with frameto be not less than 38 kg (weight of cover 23kg and weight of frame 15 kg) R.C.C. top slabwith 1:2:4 mix (1 cement :2 fine sand : 4graded stone aggregate 20 mm nominal size)foundation concrete 1:5:10 (1 cement: 5 finesand : 10 graded stone aggregate 40 mmnominal size), inside plastering 12 mm thickwith cement mortar 1:3 (1 cement: 3 fine sand)finished smooth with a floating coat of neatcement on walls and bed concrete etc.complete as per standard design :Inside dimensions 455x610 mm and 45 cm deep for single pipe line |
| 96 | Providing and fixing PTMT pillar cock of approvedquality and colour .15mm nominal bore, 107mm long, weighing not less than 110 grams. |
| 97 | Providing and fixing gun metal non-return valve of approved quality (screwed end): i) 32 mm nominal bore Vertical each |
| 98 | ii) 40 mm nominal bore Horizontal each |
| 99 | Cutting holes upto 30x30 cm in walls including making good the same : With 1st class bricks. |
| 100 | Cleaning of exposed concrete surface of stickingmaterial including loose and foreign material by sand blasting with fine sand followed by and including cleaning with oil free air blast as required and as per direction of the Engineer-in-charge. |
| 101 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound, as directed by Engineer-in- Charge and consisting of applying :(a) after surface preparation, first layer of slurry ofcement @ 0.488 kg/sqm mixed with water proofingcement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and fine sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.For the purpose of measurement the entire treated surface will be measured. |
| 102 | Grading roof for water proofing treatment complete as required as per direction of the Engineer-in-charge with : Cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size) |
| 103 | Providing & applying superlatex(SBR based) or equivalent water proofing coating over RCC slab/ brick wall with three components by mixing super latex or equivalent, water, cement @ 1:4:7 or as per manufacturer recommendation in/c cleaning the roof surface with weir brushing & with clean water before application & curing the chemical by sprinkling water for 3 to 5 days after applixcation of water proofing compound complete as per direction of the E-In-C & technical instruction of the manufacturer. |
| 104 | Providing and fixing white vitreous china wash basin of HINDWARE/PARRYWARE/JAQUAR (as selected and approved) with long pedestal, CI brackets, 32 mm CP brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required as per direction of the Engg-in-charge: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps. |
| 105 | Providing and fixing white vitreous china European type low level W.C pan of JAQUAR/HINDWARE/PARRYWARE with seat and lid including white vitreous china flushing cistern (as selected and approved) with manually controlled device with all fittings and fixtures complete in/cl cutting and making good the walls and floors wherever required as per direction of the Engg-in-charge: |
| 106 | Providing and fixing 2-in-1 CP pillar cock (fome) of JAQUAR/PARRYARE/ROYAL/HINDWARE as selected and approved at VVIP quarter as per direction of the E-In-C. |
| 107 | Providing and fixing 3-in-1 CP wall mixture tap of JAQUAR/PARRYARE/HINDWARE as selected and approved at VVIP quarter as per direction of the E-In-C. |
| 108 | Providing and fixing 2-in-1 bib cock of JAQUAR/PARRYARE/HINDWARE as selected and approved at VVIP quarter as per direction of the E-In-C. |
| 109 | Providing and fixing GODREJ SILVER STEEL hydraulic door closer with double speed adjustment with necessary accessories and screws etc complete as selected and approved as per direction of the E-In-C. |
| 110 | Refitting,fixing of old shutters for doors/windows after necessary repairs with nails, screws,hinges etc. as per direction of the E-In-C. |
| 111 | Labour charge for washing GI pipe internal for removing iron deposited iron etc. in/c. replacement of the pipe from original positionas per direction of Eng.-in –Chargea)15 mm. to 40 mm.dia. |
| 112 | Clearing & uprooting of banian trees in/c roots from the roof & walls ofdifferent office buildings/qtrs in/c disposal of rubbish etc upto 50.00mtr as per direction of the Eng-In-Charge. |
| 113 | Labour charge for cleaning inspection chamber with night soil & refusal water as per direction of the Eng-In-Charge. |