Tender For Supply Of Fire Fighting Equipments For Use In The Fire Brigade Of Udaipur Municipal Corporation On Annual Rate Contract. (E_01 / Fire_01) - GumBootTechnicalSpecificationProduct:ElectricalInsulatingFiremanBootSize range Euro: 36 – 50UK:3½-14½US:4½-15½Typeof constructionVulcanizedRubberUpperandSoleRecommendationStructuralfirefighting,Generalfirerescue,BushfirefightingEuropeanStandardCEApprovedsuitableforfirerescue,firesuppression, property conservation & etc.HighElectricalResistanceOutsole,HeatInsulationColdInsulationSlipResistanceonceramictilewithSodiumLaurylSulphateFuel Oil Resistant OutsoleHeel Energy AbsorptionNailPenetrationResistanceToeProtectionResistant to hot contactToeprotectionCompressionresistanceNailpenetrationresistance18kVElectricShockResistanceprotectionLiningMaterialExtracomfortwithwovencottoncanvasUpperconstructionFlameretardantupperwithheatinsulationWaterproofReinforcedrubberHighvisibilitywithblackandyellowcontrastSole/HeelFlameretardantrubberoutsoleFueloilresistantsolesuitableforinimicalenvironmentSlipresistantvulcanizedrubberoutsoleExcellentabrasionresistantforextradurabilityHeelenergyabsorptiondesigntominimizeheelimpactCatered to enter high temperatureColdinsulationsoleconstructionSteelToeCapEpoxycoatedtoecapsforanti-corrosionMeetsimpactandcompressiontestsMetaltoecapprovidesreliableprotectionincold&hotenvironmentsSteelMidsoleNon-corrosive stainless steelWithstandspin& sharpobjectsChemicalResistanceSole&Upper–ResistanttowardsstrongacidsandalkaliFinishingLacquercoatingforweatherprotection HelmateNew, modern design and excellent protection properties. Optimalrelationshipbetweenprotectionandcomfortwithabroadspectrumofoptional upgrades. Structural fi refi ghting has never been safer.PERFORMANCEExtremetemperatureresistance(upto1,000°Cina10secondflashoverfl ames)Long-termtemperatureresistance(radiantheattest14kW/m2)HighresistancetomechanicalimpactsLow-temperatureclassification–30°CSAFETYElectricalinsulationcapacityheadprotection(includingneckandface)Interior shock absorberReflectiveelementsforbettervisibilityinlow-lightconditionsNeckprotector(availableinaluminisedfibre,Nomex,genuineleatheror wool for Holland style)3pointchinstrap(testedtopreventskinirritation,fireretardantaramidtape) Chemical resistanceCOMFORTLightweightIntegratedadjustmentsystemOneshellsizeforheadsizesfrom52to64cmWiderangeofaccessoriesand high level of personalisationHIGHTECHMATERIALSFlameretardantandhightemperatureresistantcompositeAnti-scratchand anti-fog coated integrated visorAnti-scratch and anti-fog coatedintegratedgoggle GlovesProductDescriptionFirefightingHandGlovesMake-FlaredefendTheuppermaterialisbeefhidesplitwithspecialtreatmentagainsthightemperature, penetration of water and oils.Another function of this leather treatment is resistance againstmechanicalrisks.Thenextlayeriscompositionthatincreasesresistanceagainst heat, abrasionTheglovesaretestedandcertifiedaccordingtoProtectionforFirefighters. SelfcontaincomprasairBASatA)The breathing apparatus should accept a range ofcompressed air cylinders( B) BA set shall contain air cylinder,back plate, facemask, lung demand regulator, pressurereducingvalve,pressuregauges,hoses,carryingcase,etc.(C)Theminimumdurationofuseofthesetshallnotbelessthan45minutes.ISOprovidesperformancespecificationsoftheselfcontainedair-breathingapparatus(SCBA)(notusingstoredoxygen) Highledsearchlight55WMATERIALThebodyismadeofhighstrengthbutlightweightABCplastic,lendingitrigidity and toughness even in situations of rough handling. Whateverthe situation, you can laways bank on this solidly built, rain-proof FOSLED Search Light.LEDPOWERFeaturing a high power 20W branded LED coupled with a big parabolicreflector,thisFOSrechargeabletorchoffersunmatchedluminosityofupto 1800 lumens with a focesed beam range visibility of up to 2 kms.BATTERYPOWERPowering the LED is a high-performance 2400 mAh, 7.4V Lithium-ionbattery which offers a battery backup of up to 5 hours. The packagecomeswith2batterychargers,anACWallChargingAdapterandaCarCharging Adapter, both with 9 V-1 Amp. Output.LIGHTMODESThis heavy duty ewchargeable handheld torch comes with 2 lightbrightnessmodes,i.e.superstrongandstrong,whichcanbeusedasperyour lighting needs.UserApplicationHeavydutyoutdoorultra-long-rangelighting applicationsas commercialsearchoperationsforArmedForces,Industries,SecurityAgencies. Multi Purpose branchConnection-21/2”,2”,11/4”Application-FIREFIGHTINGMaterial-Aluminum,Alloy,StainlessSteelSize-63mm, 40mm, 50mmFlow-600LPM,800LPM,900LPM,1200LPMPressure-7KG/CM2Hydrulic Test- 30KGWarranty- 5 YEARPressureBar-7KG/CM2InletConnections-63MM,40MM, 50MM MultiPurposeNozzelFlow600Ipmto950LPM(110to210GPM)Inletsize:2½”(63mm)orasperRequirmentMeterial : Light weight hard coat anodizedALUMINIUMMaterial:StainlessSteel,BrassandAllTypeManufacturingSpary Angle : 120 Degree & 130 DegreeBumper:Rubberbumperwithteeth.Mode : Jet, spray and shut offThrow:Above35Mtr.FireHoseReelNozzle,PVCNozzlePlastic,FireHoseReelNozzleAllType.Specifications:DCGunType:OrdinaryDCGunNozzle Material : NylonWorkPressure:12 BarSize:1 1/2”,2”,2 1/2”Flow:600,900,1200LPMPressure:3to7BARWarrantyGuarantee:5YEAR LowerPressureApplicatorInlet–Pipe – Aluminum AlloyNozzle–BrassExtrudedRodSize–63mmMaleinstantaneousinletTest Pressure – 21 BarWorkingPressure–7BarDischargePattern–WaterCurtainPatternFlow Rate – 130 LPM @ 7 BarDischargeRange–ThrowRange:7mMinimumFinish–NaturalSSFinishPolished FireResistantDangries• 100% COTTON Fire Retardant Premium Fabric in 230 GSMadhering to ISO 11612:2015 A1 and A2.• 2 Front pockets with Quality Ring Buttons, 2 side pockets, 1tool pocket, 1 sleeve pocket and 2 back pockets.• For high visibility, 2 inch Fire retardant 3M reflective tapeshave been stitched on the shoulder, sleeves and on theknees.• Fire retardant YKK zippers front closure, ring buttons onsleeves for closure All thestress points have been bartacked.• The size is as per actual and gives a smart fit look however ifyou need a lose fit or if worn above work clothes then go 1sizebigger.FABRIC SPECIFICATION- Premium 100% Cotton per-shrunk FireretardantpremiumFabricin230GSMadheringtoISO11612:2015A1andA2. FireProximitySuitA. Coat/Jecket1. GeneralDescription:Coatwithahighcentralzipclosure,coveredwithsuitable storm flap. The coat should have full-length sleeves and a standup collar with adjustable throat tab.2. Standard:ThecoatmustmeettheNFPA1971:2007or3. Constructiona. Thecoatshouldhaveathree-layer construction:b. Outer Cloth: The outer shell fabric should be made from inherentlyflame resistant fiber with requisite blend of antistatic fibers. The colourof the outer shell be Dark Navy Shade .c. Moisture Barrier: Moisture Barrier shall be Fire resistant andbreathableinnature.Theconstructionshouldbemicroporousin naturelikenonwovensubstrate/felt/PU/spunlacearamid–suitably laminated with PTFE / PU like membrane or treated with compound toensure that no water ingress from outside besides allowing perspirationand heat to escape from inside.d. ThermalBarrier:TheThermalBarriershould consistoftwo integratedorquiltedlayers.Theinnermostlayer facingthe MoistureBarrier shouldbe made from inherently flame resistant fibres in non wiven felt /corded lane construction.e. The should be detachable i.e., it should be able to be used as a singlelayered Coat or multiple layered Garment and should be detachable bybuttons from inside.f. Seams: All sewing to be done using para-aramid or equivalent stronginherently FR thread. The seams on the outer layer should be stitchedwith strong thread overlock.g. Pockets: Coat should be provided with 3 pockets as standard. 2 waistpockets on the lower fronts with flap closure and 1 patch pocket insidethecoat.h. Collar: The collar of the Coat should be designed so that the neckportion is doubley secured and covered by means of a throat tab, fittedwith fire retardant Velcro for secure fastening across the neck. A hangerloop, centrally placed on outer collar or inside section to be provided tofacilitatehanging.i. FrontClosureThe coat should have a heavy-duty moulded zip beneath a full lengthcatch flap, closing with fire retardant Velcro.j. Sleevs & Cuffs: The sleeve should be designed to have an additionalgusset (all 3 layers) in the underarm or any other design innovation toallow the arms to move freely without raising the hem of the coat. Anaramid rib-knitted internal cuff to be provided for suitable wristprotection.k. Reflective Tape: The Coat should have a high quality reflective tapeprovided at the following places.- Single row 50 mm width, around hem / waist (including across frontflap)- Singlerow50mmwidth,aroundlowersleevesThe tape should be premium quality and the quality should comply withthe length and test parameters stipulated in the corresponding NFPA /Enstandreds.l. Sizing: Size chart should be provided along-with the offer. The sizeshould be suitable for fitting on person of 5’10” & 5’ 8” height.m. Labels: A large clear label should be permanently attached (sealed)or stitched inside the lining of the fire suit. This label should give fulldetailsofcompliancetointernationalstandards,manufacturers’contactdetails, sizing, wash/care information, style and date of manufactureand traceability coding. B. TROUSER1. General Description: Trouser should have standard 36 inch &32 inch waist size and adjustable crossover braces, with theknees suitably padded and reinforced with an extra layer ofouter cloth. The waistof the Trousershould be elasticized atboth sides to provide a comfortable flexible fit.2. Standard: The fire Trouser must meet the NFPA 1971 : 2007or their latest applicable version.The Suit should bear UL marking(for NFPA certified suit)with supporting certification.3. Shape – Construction: Thetrousers should fit on the naturalwaistline (36 inch), ankle length and constructed withfollowing 3 layers:-(1) Outer Cloth: The outer shell fabric should be made frominherently flame resistant para aramid fibre material withrequisite blend of antistatic fibre. The colour of the outershell fabric shall be Dark Navy shade.(2) Moisture Barrier: Moisture Barrier shall be Fire resistant andbreathable in Nature. The Construction should be microporous in nature like non woven substrate/ felt / PU / spunlace aramid – suitably laminated with PTFE / PU likemembrane or treated with compound to ensure no wateringress from outside besides allowing perspiration and heatto escape from inside.(3) ThermalBarrier:TheThermalBarriershouldconsistoftwointegratedorquiltedlayers.Theinnermostlayerfacingthe Moisture Barrier should be made from inherently flameresistant fibers in non woven felt / corded laneconstructiong. The Trouser should be detachable i.e., itshould be able to be used as a single lovored coat multiplelovoredGormentandshouldbedetachablebybuttonefrom.4. Seams Allsewing tobedoneusing para-aramidorequivalentstrong inherently FR thread. The seams on the outer layershould be stitched with strong thread overlock,5. Knee Construction The knee should have an extra layer ofouter cloth as reinforcement or alternately an aramidenforcement. The knee region should be shaped or designedsuitably for comfprt and flexibility.6. Pockets The Trouser should have I internal patch pocketinside the right or left hip.7. Reflective Tape: The Trouser should have single row of 50mm wide reflective tape around lower leg. The tape shouldbe premium quality and should comply with test parametersstipulated in the corresponding NFPA/EN standards.8. Sizing size chart should be provided alongwith the offer. Thesizeshouldbesuitableforfittingonpersonof5’-10”height&36 inch waist.m. Labels A large clear lable should be permanently attached( sealed) or stitched to the inside pocket/ section of theTrouser. This label should give full details of compliance tointernational standards, manufacturer’s contact details,sizing, wash/care information, style and date of manufactureand traceability coding. C.ANTIFIRE HOODSSTANDARDS:CertifiedtoNFPA1971FEATURES: The Hood should be offwhitecolour.ThefaceopeningshouldbeFitandFlatThe NeckProtectorshouldbe fit andproperlycoveringtheshoulders.The Hood should be double layeredhaving each layer of the Fabric ofabout230GSM,insetcollarandfaceopening with elastic. CHEMICALRETARDANTSUITS FOAMMAKINGBRANCH:1. FB5X2. FB10X3. FB20X4. InlineIndusterFoam generater ADAPTORS1- Male to Male 2- Female to Female3- Male to Female DANGARIES Size M,L,XL, XXL