| 1 | Clearingjungle includinguprootingofrank vegetation, grass, brush wood, trees and saplingsofgirthupto30cmmeasuredata height of 1 m above ground level and removalof rubbishuptoadistance of50m outside the periphery of the area cleared. |
| 2 | Earth work in excavation bymechanical means(HydraulicExcavator)manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan)includingdressingofsidesand ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositingandrefillingofjhiriwith watering&ramminganddisposalof surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils |
| 3 | Fillingavailableexcavatedearth(excluding rock)intrenchesplinthsideoffoundation etc. in layers not exceeding 20 cm in depth consolidationeachdepositedlayerby ramming and watering including lead up to 50 mtr and with all lift. |
| 4 | Supplyingchemicalemulsioninsealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20% |
| 5 | Diluting and injection Chloropyrifos Emulsifiableconcentrate20%with1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuouschemicalbarrierunderand aroundthecolumnpits,walltrenches, basementexcavation,topsurfaceofplinth filling,junctionofwallandflooralongthe external perimeter of building expansion joints,overthetopsurfaceofconsolidated earthofwhichaprochistobelaid surroundingofpipesandconduitsetc. completeasper specification(Plinthfloor area only shall be measured for payment and excluding the cost of chemical emulsion). |
| 6 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 7 | RandomRubblestonemasonryforwith hardstoneinfoundationandplinthin CementSandmortarabove30CMthick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 8 | Random rubble dry stone kharanja under floor. |
| 9 | Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement.M25 grade Design Mix |
| 10 | Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M25 grade Design Mix |
| 11 | Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M25 grade Design Mix |
| 12 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending,placinginpositionandbinding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code 1786) |
| 13 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. |
| 14 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Columns, pillars, posts and struts etc. |
| 15 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. |
| 16 | Brick work with F.P.S. bricksof class designation 75 in superstructure above plinthlevel uptofloor Vlevel inall shapes and sizes in : Cementmortar1:6(1cement:6coarse sand) |
| 17 | Half brick masonry in Superstructure, above plinthlevelupto floor V level using bricks ofdesignation75 Cementmortar1:4(1 cement : 4 coarse sand) |
| 18 | HalfbrickmasonryinSuperstructure, above plinth level upto floor Vlevelusing bricks of designation 75Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 19 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steelTee-sections,joints mitredand welded with 15x3 mm lugs 10cm long embeddedincementconcreteblocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand:6gradedstoneaggregate20mm nominalsize)orwithwoodenplugsand screwsorrawlplugsandscrewsorwith fixing clips or with bolts and nuts as require including fixingofnecessarybutthinges and screwsand applying a primingcoat of approved steel primer. |
| 20 | Providing and fixing steel glazed window frame made out of80x40mmhollow sheet sectionof16gaugethickness,jointmitred weldedandgrindedincludingholdfastof steellugs13mmx3mmand15Cmlong embeddedinCCblock15x10x10Cmof 1:3:6nominalconcreteandincludingfixing of pivoted hinges of superior quality, window shuttersmadeoutof50x25.0mmhollow steelsection15 mm paitam of18gauge thickness,joint mitred andgrinded including 10mm x 10mm square bars welded to frame for paitam fixing float glass 4mm thick panes withglazingclipsandmetalsashputtyand fixingofshuttersframespegstay,Ushape handle100mmlong,towerbolts100mm long of steel powder coated superior quality including fixingand jointingwith frame hingesprimingcoatwithsteelprimer completeinallrespectasperdirectionof Engineer-in –charge Window openble |
| 21 | V Fixed |
| 22 | Providing and fixing of double leaf steel shutter for cupboard, the Sqm frame is made of pressed steel ISI section 80x25mmx 1.25 mmthickwith1.00mmMSsheettospot weldedincludingholdfastsof15x3mm,MS oxidizedfittingssuchasbutthinges,sliding doorsbolts,handles,towerboltsandtwin pegetccompleteincludingapplying priming coatofapprovedsteelprimerofredoxide zinc chromate and spray painting in approved shade with deco paint of approved quality complete as per direction of Engineer In Charge |
| 23 | Providing and fixing M.S. sheet 1mm thick dabble leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint |
| 24 | Providing and fixing squre bars or other glat welded to window,ventiator,door etc (8mm squre bar for window) |
| 25 | Plaster on newsurface on walls in cement sand mortar 1:4 including rackingof joints etc.completefinefinish:20mm thick.includingall stage with scaffolding |
| 26 | Plaster on newsurface on walls in cement sand mortar 1:4 including rackingof joints etc.completefinefinish:20mm thick.includingall stage with scaffolding |
| 27 | 6 mm thick cement plaster to ceiling of mix 1:3 (1cement : 3-fine sand) |
| 28 | Providingandlayingbrickkharanja onroofs withcementmortar1:4(1cement:4coarse sand)mixedwith2%integralwaterproofing compound in square pattern 75mm to 100mm thick average |
| 29 | Supplyingandapplyingbituminoussolution primeronroofsoronwallsurfaceat0.24 litre per sqm. |
| 30 | ProvidingandlayingCeramicMATfloor tiles(thickness to bespecified bythe manufacturer)of1stqualityconforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brownofanysize,laidon20mmthick bedofcementmortar1:4(1cement:4 coarsesand) includingpointinginwhite cementmixed with pigmentof matching shade complete. |
| 31 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in charge in skiriting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white mixed with pigment of matching shade complete. |
| 32 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) Dark shade using ordinary cement. |
| 33 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars,steps,Shelves,SillsCounters,Floors etc. 15-18 mm thick laid on 12mm (Av.) thick baseofcementmortar1:3(1cement:3 coarse sand) jointing with white cement mortar1:2(1white cement:2marble dust) with pigment to match theshade ofthe marbleslabincludinggrinding,rubbingand polishing complete. South (Red) Above 3601 Cm2 Slabs |
| 34 | Providing and applying white cement based putty overplasteredsurfacetoprepare the surface even and smooth complete New plastered surface (three or more coats) |
| 35 | Distemperingwithoilboundwashable distemper ofapprovedbrandand manufacture to give an even shade including all scaffolding: New work (two or more coats) over and including scrapping and priming coat with cement primer. |
| 36 | Painting exterior surface of Wall with 100% acrylicexterior paintof approvedbrand andmanufacturetogiveanevenshade with two or more coats including prepartion of base with sand papering, primer, putty, etccompleteinallrespect. includingscaffoldingandsafetyprovision. New work |
| 37 | Finishing walls with textured exterior paint of required shade as perapproved colour complete as per manufacturers specifications includingprimer coatand protectingcoat including scaffolding and safety provision RollerFinishav.thickness400to500 microns. Qty 20% of Putty Surface |
| 38 | Kotastoneslabflooring25mmthickover 20mm(average)thick baselaidoverand jointed with grey cement slurry mixed with pigmenttomatchtheshadeoftheslab includingrubbingandpolishingcomplete with skarting as per require base of cement mortar 1 : 4 (1 cement : 4 coarse sand). For areaof each slab from 901 to 2000 Sq.Cm |
| 39 | Painting with synthetic enamel paint of approvedbrandandmanufactureto give an even shade :Two or more coats on new work |
| 40 | Extra for lining out plaster to imitate stone or concrete blocks walling |
| 41 | MakingofDripcourse(Tapaka)incement sandmortar1:6widthupto40mmand10 mm thick as per approved design |
| 42 | Making grooves as per design in plaster 10mm to 20mm wide |
| 43 | ProvidingandFixingChikenwiremeshat the joint of masonry members/ R.C.C. MemberswithNailscompleteinall respect. |
| 44 | Providing & Fixing Premium Quality white glazed vitreous china Sanitary Wares (IS:2556 Mark) of approved make as per direction of Engineer-in-charge including cutting and making good the wall and floor. W.C. orissa pan with 100 mm vitreous china P or S trap (Size 580x440 mm.) |
| 45 | P & F vitreous china P trap of approved quality |
| 46 | P & F C.P. Brass flush Valve with C.P. flush bend of approved make. Economy model 32 mm dia. |
| 47 | P & F Grating of approved quality/make: Stainless Steel Sheet size 125mm dia. |
| 48 | P&FEuropeantypewhiteglazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor |
| 49 | P&FwaterclosetSeatCoverswith brass hinges complete : SolidPVC(IS2548marked)grade-I Black for EWC. |
| 50 | P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I.bracketsdulypainted,brassball cockwithball(IS:1703mark) complete including cutting and making good the wall:PVC with PVC bend as per IS : 7231. |
| 51 | P&FBevellededgeMirror/mirrorwith teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thickcommercialplybasefixedto wooden screws & washers.Size 600 x 450mm x 4 mm thick |
| 52 | P& F Toilet Shelf of approved quality/make: Acrylic shelf on C.P. brass casted brackets & guard railofapproved make as per direction of EI ofsize 550x125mm |
| 53 | P&FGratingofapprovedquality/make: Stainless Steel Sheet size 125mm dia. |
| 54 | P&FBathShower ofapproved quality/make. C.P. brass ofHeavy & superior quality, revolving with adjustablekey 150mm. |
| 55 | P & F Shower arm 15mm dia of approved quality/make.C.P.brass heavy & superior quality 150mmProjection. |
| 56 | P&FTowelRailorRingofapproved quality/make: C.P. brass Towel Rail elbow type withconcealedscrewssize 600mm (Heavy duty). |
| 57 | P&FSoapDishorTrayofapproved quality/ make. C.P.brassheavyand superior quality. |
| 58 | P & F Liquid Soap Container with brackets complete of approved make: C.P. brass |
| 59 | P&FToothPaste&BrushHolderofapproved quality/make: C.P. brass |
| 60 | P & F Jet spray for water closetwith C.P. Copper Tube flange of approved make. |
| 61 | P&FW.V.C.(IS:2556Mark)Squatting Urinal of standard make complete. Including cutting & making good the floor: Size 450x350mm |
| 62 | P&F Marble Urinal Partition slab both sides polished of approved design cut from marble size 900x600mm. Makrana II quality marble having light spots |
| 63 | P&FWVCWashbasin(Istquality IS:2556 Mark) of approved make with C.I.bracketsdulypainted1No.15 mmC.P.Pillarcock(IS:8934Mark) & 32mmC.P.brasswastecouplingof approved make, P.V.C Waste pipe withPVCnut32mmcomplete includingcutting&makinggoodthe wall : |
| 64 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall) 15 mm dia nominal bore B class |
| 65 | 25 mm dia nominal bore B class |
| 66 | 32 mm dia nominal bore B class |
| 67 | P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: C.P. Brass bib cock,15mm nominal bore. |
| 68 | (-do-) Long body, 15mm nominal bore weight not less than 690 gm |
| 69 | P & F Stop Cock (IS :8931 Mark), superior quality & of approved make: C.P. Brass 15mm nominal bore. |
| 70 | (-do-) Concealed stop cock 15mm |
| 71 | P & F Flush Cock / Flush Valve (IS : 9758 Mark) for WC of approved quality make : CP brass Concealed 25mm nominal bore. |
| 72 | P & F Full way valve (IS : 778 mark or wheel valve of approved make.Gun-metal 15 mm dia nominal bore |
| 73 | Gun-metal 25 mm dia nominal bore |
| 74 | Gun-metal 32 mm dia nominal bore |
| 75 | P & F Gun-metal Non-return Valve or Check Valve (IS : 778 Make) of approved make, superior quality: 25mm nominal bore. Horizontal |
| 76 | Vertical |
| 77 | P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 1000 litres capacity. |
| 78 | P & F Ball Cock (IS :1703 Mark) with Rod & P.V.C. Ball complete : Brass wt. Not less than 300 gm,15mm. |
| 79 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2 .) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 75 mm dia |
| 80 | 110 mm dia |
| 81 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Coppler 110 mm dia |
| 82 | 75 mm |
| 83 | Plain Tee 110 mm dia |
| 84 | 75 mm |
| 85 | Vent Cowel 110 mm dia |
| 86 | Bend 75mm |
| 87 | 110 mm dia |
| 88 | Plain Floor Trap 110 mm dia |
| 89 | Pipe Clip 110 mm dia |
| 90 | 75 mm |
| 91 | 110mm dia |
| 92 | Construction of chamber in all type of soil with300mmthickmasonryinCM1:6 m,10cmthickC.C.1:5:10infoundation, 20mm thickinsider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. Inside size 450 X 450 mm depth upto 0.5 MCement cover with frame. |
| 93 | 150mm dia S.W. pipe |
| 94 | Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C flooring & over stone slab covering ,80 mm thick slab ,jointing of slab in CM 1:3. Ralthal, Kharanja,50 mm thick stone partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos C.I foot rests of approved design ,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- Size 400 x140x150 cm.(for 50 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 10mm ϕ @15 cm c/c,bothways including shuttering complete in all respec |
| 95 | Add extra if R.C.C slab of designed thickness & reinforcement is provided on manhole in place of stone slab( Actual area of R.C.C slab to be measured). |
| 96 | 450mm dia, 5Kg. C.I. frameto with stand 3 MT center point load & minimum unfracturedload of 1 MT. (Light duty). |
| 97 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it\"sISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR Short point (up to 3 mtr.) |
| 98 | Medium point (up to 6 mtr.) |
| 99 | Long point(up to 10 mtr.) |
| 100 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it\"s ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR On board |
| 101 | Long point(up to 10 mtr..) |
| 102 | Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 5 step fan regulator 2 Module 360 dgree rotating |
| 103 | Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 104 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 105 | 1 x 4.0 sq.mm |
| 106 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR Single pole MCB (With B/C curve tripping Characteristics)10A rating |
| 107 | Glazeddoor(Threephase)IK-09andIP-43with Metal end box 6 Way |
| 108 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 20 mm |
| 109 | 25 mm |
| 110 | P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 111 | Providing & Fixing ofextra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe including cutting, threading, drilling, fixing quarter pin etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 112 | Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .1170mm(+/-10%) LED batten with min. lumen output 2200 lm |
| 113 | Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) |
| 114 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .LED Street Light fixture with Minimum lumen output 11225 lm |
| 115 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR8 SWG tinned copper Wire |