| 1 | Construction of Record room building in DRDA building 2nd floor in Viluppuram District |
| 2 | Clean removal of Cement Plaster from walls and racking out joints 12 mm deep labour charges only |
| 3 | Dismantling,Clearing away and carefully stacking materials useful for reuse for any thickness of Brick work wall in cement mortor |
| 4 | Dismantling RCC using deploying machineries |
| 5 | Dismantling , Clearing away and carefully stacking materiales useful for re-use One course of Pressed Tiles and weathering course etc complete . |
| 6 | Cement concrete 1:2:4 mix using 20mm ISS metal including cost and conveyance of all materials to site and all labour charges for mixing, laying and curing etc completefor 10 cum. |
| 7 | Supplying and Erection centering for sides and soffiots including necessaary supports and strutting as directed by the departmental officers. Rate for 10m2 for the following items (RCC floor slab, roff slab, Rectangular / Square, Tee/ Ell beams, Lintels, StairCase Waist Slablanding slab landing beam Canopy etc in all floors with all cross Bracings using mild steel sheets of size 90cm x 60cm and 10BG stiffened withmild steel angles of size 25mmx3mm for boarding laid over country wood joists of size 10cmx6.50cm spaced at about 90cm centre to centre and supported by Casurina props of 10cm to 13cm dia spaced at 75cm centre etc, complete and as directed. |
| 8 | For Second Floor Centering |
| 9 | For Sill Slab Lintel, Portico Beam |
| 10 | Lintel Sides |
| 11 | Providing Additional Strutting to Centering of RCC Slabs of Plain Surface for every additional 1.00 meter Height or Part thereof but not less than 30 cm, over the initial 3.00 m height from Floor Level using Casuririna props of 10 cm to 13 cm dia including cross bracing etc complete complying with standard specificatios and as directed by the Departmental officers etc complete . |
| 12 | Supplying, Fabricatung and placin g in position of RTS or MS rod for all reinforced cement concrete works as per design given including cost of steel and binding wire in all floors etc,complete complying with standard specification |
| 13 | Providing and Laying in position machine batched,machine mixed and machine Vibrated Design Mix Cement Concrete of M25 Grade for Reienforced Cementratio with plasticiser using 20 mm and down concrete structural elements under controlled water graded machne broken stone jelly excluding the cost of centering and shuttering and Reinforcement but including curing,fixing,fan clamps etc., as per standard specification and as directed by the deparrtmental officers complete. |
| 14 | Brick Work in Cement Mortor 1 : 5 mix using Country Bricks of size 22 x 11 x 7 cm including cost and conveyance of all materials and labour charges etc complete . |
| 15 | Brick Work in Cement Mortor 1 : 5 mix using Country Bricks of size 22 x 11 x 7 cm including cost and conveyance of all materials and labour charges etc complete . |
| 16 | Brick Partion Walls of 11.00 cm thicknessusing best quality Country Brickks of size 22 x11x7 cm in Cement mortar 1:3 (one Cement and Three Sand) using Hoop iron reinforcement if found necessary including curing etc complete and as directed by the departmental officers (Hoop iron reinforcement will be measured and paid separately) |
| 17 | Special Ceiling Plastering and finishing all RCC exposed surfaces such as RCC Slabs,Canopies,sunshades,landing slab Beams ,etc with CementMortor 1:3, 10mm thick (one cement and three sand)including cost and conveyance of all materials and labour charges etc complete as directed by the departmental officers etc complete complying with standard specification. |
| 18 | Providing GronolothickFloor Finish 25 mm Thick in Cement Concrete 1 ; 2 : 4 mixby using 10 - 12 mm iss hbg chips and M.Sandincluding cost and conveyance of all materials and labour charges etc complete |
| 19 | Providing ,Fabricating and Fixing M.S Grills for Windows, Ventilators, Gate and Lader etc.,made out of MS Rods, Flats,Angles,pipes,Channel etc including necessary fixtures complete as per requirement and specification and as directed by the Engineer . |
| 20 | Door Frame : Supplying and fixing First Quality Teak Wood frames for Doors,windows,Ventilators and other similar Joinery works with the following sizes and sections including labour charges for wrought and puttup in position and also for fixing in Hold Fast in frames and masonry in all floors etc complete |
| 21 | a.Teak wood Scantling upto 2.00 metre |
| 22 | b.Teak wood Scantling above 3.00 metre and below 3.00 meter |
| 23 | Providing and fixing PVC Rain Water Down Fall Pipe of following pipes with necessesary shoes , bends and other specials clamps,screws,nails,teak wood plugs etc,. Complete including cost of all materials etc -3 RM |
| 24 | Supply and Fixingof 35 mm thick single Leaf High Density Interior Grade marine Ply Wood Shutters pasted bothsideswith 4mm thick OST Ply pf approved Design with 35 x 12 mm T.W Lippng on all edges with necessary Adhesives and CP Screws complying with standard specfications .The Cost is inclusive of one no Mortise Lock ,Handle,tower bolt ,approved equvalent make SS Hinges of equvalant make of approved maKE, Two No Floor mounted SS Door Stopper etc complete. |
| 25 | UPVC WINDOW Supplying and fixing upvc ( Un Plasticized Polyvinyl Chloride ) windows of casement type (open) frm the profile size of outer frame 60 mm x 58 mm and shutter profilre are reinforcement with gi/1mm 125GSM and 100 % corrosion free, the profiles are muli chamberedcv section with wall thick of 2 mm . The EPDM rubber (block colour ) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power points locks and also it operates as handle. The corners and joints should be welded and cleaned.Radiations free pin headed or plain glass 4 mm thick should be provided to the shutter andit should not allow leakage of water even atmost ranging storms and should have key lockable action, Security protective hinges,strong locking systems and as per size for arresting noise and Energy loss. |
| 26 | UPVC VENTILATOR : Supplying and fixing UPVC ( Un Plasticized Polyvinyl Chloride ) Louvered Ventilators of from the profile the size of Outer frame 60 x 58 mmand shutter profilethe size of 60 x 78 mm both profile size of 60 x 78 mm both profiles are reinforced with GI/1 MM 125 GSM and 100 % corrosion free ,the profile are multi chambered sections with wall thick of 2 mm .The EPDM RUBBER ( BLACK COLOUR ) Covered with all over the edges of frame and Shutter. .TheCornerandjoints shuld be welded and cleaned .Radiation Pin headed Glass 4 mm thick should be fixed to the wall with 100 % packing with screws and silicon packing all around the frame .The Ventilator should be got approved from the Executive Engineer before use on work . |
| 27 | Painting Two Coats of Synthetic Enamel Paint of approved Colour and make over one coat of anti corrosive Zinchromite primer over New Steel work suitably prepared for receiving the paint by surface scraping rubbing applying filleretc ,including cost of filler ,primer paint all complete as per specifications |
| 28 | Distembering Two Coats with Primer coat and Two Coat with OIL BOUND DISTEMBER over cement plastered surface including all charges etc complete |
| 29 | Painting Two Coats with approved Exterior Emulsion over the Plastered surface over one coat of Primer paint including cost of all materials and labour charges etc complete |
| 30 | Painting Two Coats of Synthetic Enamel Paint of approved Colour and make over one coat of WOOD primer over NewWood work suitably prepared for receiving the paint by surface scraping rubbing applying filleretc ,including cost of filler ,primer paint all complete as per specifications |
| 31 | Wiring with 2 x 1.50 sqm ( 22/0.3) PVC insulated SC unsheathedCu Conductor of 1100 v Grade in suitable PVC Rigid Pipe Concealed in wall and ceiling with PVC accesseries,in flush with wall , with TW box 150 mm x 100 mm x 113 mm TW Switch box with 3 mm thick Hylem sheet coverfor 5A3 Pin non inter locking CS plug with painting of suitable colour with contionues earth wire connection of 14 SWG TC Wire and making good of the concealed portion with suitable colour for Concealed Plug Point SD No 38 for PVC PLUG Point |
| 32 | Wiring with 2 x 1.50 sqm ( 22/0.3) PVC insulated unsheathed single core Copper Conductor of 1100 v Grade in suitable PVC Rigid Pipe concealed in wall and ceiling with PVC accesseries with TW Switch box with 5 A F . T . Switchand making good of the concealed portionwithsuitable colour forPVCConcealed Light Point and Fan Point S D N o 16 |
| 33 | Supply and Fixing of fancy glass shade and11 WCFL in the existing light point SDnO 80 |
| 34 | Supply and Fuixing of Water TIGHT Bulk Head fitting with Guard suitable for 11 wlamp withCFL SD No 83 |
| 35 | Supply and fixing of 1200 mm ( 48\" ) A C Ceiling Fan complete with stepped eloctronic 300 w regulator with 1.00 meter down Rod on the existing clamp S D N o 107 |
| 36 | cost and supply of cuddapa slab |
| 37 | Name BoardLS |
| 38 | GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column \"BB\" for all works in this package} |