Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-09-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 25-09-2025 |
| 2 | 17-09-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 22-09-2025 |
| 3 | 10-09-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 17-09-2025 |
| 4 | 27-08-2025 | c13 | Date | 10-09-2025 |
| 5 | 27-08-2025 | C12 | BOQ | 10-09-2025 |
| 6 | 20-08-2025 | Corrigendum No 11 | Date | 03-09-2025 |
| 7 | 08-08-2025 | Corrigendum NO 10 | Date | 27-08-2025 |
| 8 | 01-08-2025 | Corrigendum NO 09 | Date | 18-08-2025 |
| 9 | 19-07-2025 | Corrigendum NO 08 | Date | 08-08-2025 |
| 10 | 08-07-2025 | Corrigendum NO 07 | Other | 28-07-2025 |
| 11 | 08-07-2025 | Corrigendum NO 06 | Date | 28-07-2025 |
| 12 | 01-07-2025 | Corrigendum No 05 | Date | 15-07-2025 |
| 13 | 21-06-2025 | Corrigendum No 04 | Date | 08-07-2025 |
| 14 | 10-06-2025 | Corrigendum No 03 | Date | 01-07-2025 |
| 15 | 26-05-2025 | Corrigendum No 02 | Date | 21-06-2025 |
| 16 | 15-05-2025 | Corrigendum No 01 | Date | 06-06-2025 |
| Sl. No. | Item Description |
| 1 | Schedule \"A\" Acoustic wall panneling |
| 2 | Item No. 01 : PET PANEL PANELING @ 8 FEET FROM FFL : Supply Installation Testing and Commissioning ofPet panelswith acoustical properties made of 100 % polyster fibre with thickness of 9 mm homogenieous material with so many color option as per the choice of the architect / person in charge of size 2440 mm x 1220 mm. Can be cut in to any size for E G like 600 mm x 600 mm 1200 mm x 600 mm etc. as per client requirement. NRC Value of the eccoboard will 0.6. should be weather ressitant with anti fungal properties. Thermal insulation should be easy to install with the help of water proof bostik / fevicol SR 505 Adhesive. on the walls of the auditoriumusing GI frame work of 48mm GI Studs using 0.55mm thick and stud channels at 610mm x 610mm, 0.5mm thick, fixed with MS angle cleats 1220x610mm centers to wall by using metal fasteners, backed with 24 SWG x 12.5mm GI Chicken Wire Mesh with air gap a minimum of 50mm on back side, as per detailed drawing. The frame work to be filled with 50 mm thick micron having the density of 1000 GSM to achievethe 1.0 NRC valueThen 8 mm perforated Boiling Water Proof, FR is Born Tough HDF Board density is above 1000 kg/m3 Borer Proof and Termite proof board will be nailed on G.I. frame. Finally9mm thick pet panels will be paste on 8 mm perforated board with the help of S.R. |
| 3 | Item No. 02 : STRECHED FABRIC IN UPVC GRIPPER PANELING FROM 8 FEET TILL CEILING LVLSupply Installation Testing and Commissioning of Acoustical Panels on the side and back wall of the auditorium usingGI frame of 48mm GI Studs using 0.55mm thick and stud channels at 610mm x 610mm, 0.5mm thick, fixed with GI angle1220x610mm centers to wall by using metal fasteners, backed with 24 SWG x 12.5mm GI Chicken Wire Mesh with air gap a minimum of 50mm on back side, as per detailed drawing,50 mm thick synthetic wool having the density of 1000 GSM to achieve the 1.0 NRC value, and chicken wire mesh support on the rear side abuting the wall face. Finallystreched fabric will tucked into the gripper strips teeth and a tool stretch it tightly beforefastening. this creates a smooth wrinkle free surfacefinish, using UPVC grippers fixed to8 mm perforated Boiling Water Proof, FR is Born Tough HDF Board density is above 1000 kg/m3 Borer Proof and Termite proof board . |
| 4 | Item No. 03 : PET PANEL PANELING IN BETWEEN FABRIC PANELINGSupply Installation Testing and Commissioning Pet panelswith acoustical properties made of 100 % polyster fibre with thickness of 9 mm homogenieous material with so many color option as per the choice of the architect / person in charge of size 2440 mm x 1220 mm. Can be cut in to any size for E G like 600 mm x 600 mm 1200 mm x 600 mm etc. as per client requirement.NRC Value of the eccoboard will 0.6. should be weather ressitant with anti fungal properties. Thermal insulation should be easy to install with the help of water proof bostik / fevicol SR 505 Adhesiveon the side walls of the auditorium using GI frame work of 48mm GI Studs using 0.55mm thick and stud channels at 610mm x 610mm, 0.5mm thick, fixed with MS angle cleats 1220x610mm centers to wall by using metal fasteners, backed with 24 SWG x 12.5mm GI Chicken Wire Mesh with air gap a minimum of 50mm on back side, as per detailed drawing. The frame work to befilled with 50 mm thick micron insulation synthetic wool having the density of 1000 GSM to achievethe 1.0 NRC valueThen 8 mm perforatedboard will be nailed on g.i frame.Finally9mm thick pet panels will be pasted on8 mm perforated Boiling Water Proof, FR is Born Tough HDF Board density is above 1000 kg/m3 Borer Proof and Termite proof board with the help of S.R |
| 5 | Item No. 04 : STAGE WALL PANELING Supply Installation Testing and Commissioning Pet panelson the stage wallsusing GI frame work of 48mm GI Studs using 0.55mm thick and stud channels at 610mm x 610mm, 0.5mm thick, fixed with MS angle cleats 1220x610mm centers to wall by using metal fasteners, backed with 24 SWG x 12.5mm GI Chicken Wire Mesh with air gap a minimum of 50mm on back side, as per detailed drawing. The frame work to befilled with 50 mm thick micronhaving the density of 1000 GSM to achievethe 1.0 NRC valueThen 8 mm perforated biolo board will be nailed on g.i frame. Finally9mm thick pet panels will be paste on8 mm perforated Boiling Water Proof, FR is Born Tough HDF Board density is above 1000 kg/m3 Borer Proof and Termite proof board with the help of S.R |
| 6 | Acoustic false ceilingItem No. 05 : PET PANEL CEILINGSupply Installation Testing and Commissioning of Pet panels with acoustical properties made of 100 % polyster fibre with thickness of 9 mm homogenieous material with so many color option as per the choice of the architect / person in charge of size 2440 mm x 1220 mm. Can be cut in to any size for E G like 600 mm x 600 mm 1200 mm x 600 mm etc. as per client requirement.NRC Value of the pet panel will 0.6. should be weather ressitant with anti fungal properties. Thermal insulation should be easy to install with the help of water proof bostik / fevicol SR 505 Adhesiveon the ceiling consisting of GI perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partitionwith the help of nylon sleeves and screws, at 610mm c/c. Then suspending GI intermediate channels of size 45mm (0.9mm thick with 2 flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angles of width 25mm x 10mm x 0.55mm thick fixed to soffit with GI cleats and steel expansion fasteners. |
| 7 | Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clips and in a direction perpendicular to the intermediate channel at 457mm c/c Then8 mm perforated Boiling Water Proof, FR is Born Tough HDF Board density is above 1000 kg/m3 Borer Proof and Termite proof board will be nailed on the framework . finally 9 mm PET panels is then screw fixed to ceiling section with 25mm drywall screws at 230mm c/c. Screw fixing is done mechanically with drilling machine with suitable attachmentThe frame work to overlayedwith 50 mm thick mikron insulation synthetic wool having the density of 1000 GSM to achievethe 1.0 NRC value Pet Panel. |
| 8 | Item No. 06 : STRECHED FABRIC IN UPVC GRIPPER PANELING ON CEILING : SITC of Acoustical Panels on ceiling consisting of GI perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partitionwith the help of nylon sleeves and screws, at 610mm c/c. Then suspending GI intermediate channels of size 45mm (0.9mm thick with 2 flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angles of width 25mm x 10mm x 0.55mm thick fixed to soffit with GI cleats and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clips and in a direction perpendicular to the intermediate channel at 457mm c/c |
| 9 | The frame work to overlayedwith 50 mm thick mikron insulation synthetic wool having the density of 1000 GSM to achievethe 1.0 NRC value then. 8 mm perforated Boiling Water Proof, FR is Born Tough HDF Board density is above 1000 kg/m3 Borer Proof and Termite proof boardwill screw fixed to ceiling section with 25mm drywall screws at 230mm c/c. Screw fixing is done mechanically with drilling machine with suitable attachment. Finally 10 mm gripper will be fixed on8 mm perforated Boiling Water Proof, FR is Born Tough HDF Board density is above 1000 kg/m3 Borer Proof and Termite proof boardthe help of screws finallystreched fabric will tucked into the gripper strips teeth and a tool stretch it tightly beforefastening. this creates a smooth wrinkle free surface Fabric. |
| 10 | Item No. 07 : STAGE GRID CEILINGSupply Installation Testing and Commissioning of Stage false ceiling of 9 mm polyster fiberboard with homogenieous material with so many color option as per the choice of the architect / person in charge of size 2440 mm x 1220 mm. Can be cut in to any size for E G like 600 mm x 600 mm 1200 mm x 600 mm etc. as per client requirement.NRC Value of the pet panel will 0.6. should be weather ressitant with anti fungal properties laid over MS Suspension Grid consisting of 2 nos 40 X 40X 5mm MS Angles, welded back to back @1200mm c/c & M.S. Tees @ 600mm c/c . |
| 11 | Item No. 08 : PROCENIUM : Installation Testing and Commissioning of MS structure & fixing of 9 mm pet panels on L-angle (40x40x5) will fixed outside the provenium, then will make frame 600 x 600 c to c with MS angle (50 x 25 x 5) at center then 12mm boiling water proof, FR is born tough HDF Board density is above 1000kg/m3 borer proof and termite proof board will nailed on the MS FRAME finally 9mm polyster fiber board with homogenieous meterial with so many color option as per the choice of the architect / Person in charge of size 2440 mm x 1220mm. can be cut in to any size for E G like 600 mm x 600 mm 1200 mm x 600 mm etc. as per client requirement. NRC Value of the pet panel will 0.6 should be weather ressitant with anti fungal properties. Thermal insulation 9 mm pet panel will pasted on 12 mm board with the help of S.R. |
| 12 | Building including internal services (Acoustic Door) |
| 13 | Item No. 09 : ACOUSTIC DOOR Supply Installation Testing and Commissioning ofSystems Double leaf Wooden Acoustic Fire Door, 55mm thick, STC 45. with theAcoustic Property and 2 Hours Fire rated As per confirming IS :3614(Part-II) & BS:476 (Part 20&22) Department of Industries and Commerce, Haryana. Acoustic Fire Door having infill of Rockwool 64kg/ M3 density, Sandwiched between Two Calcium Silicate Boards without asbestos, Brucite and Meerschaum having a density not more than 1150kg/ M3 and Fire rated Ply both side with heat activated intumescent fire seal strip of size 10x4mm and EPDM Gaskets around the frame are used to enhance acoustic properties. 1mm thick Mica laminates facing on both sides in desired shade and colour. Hard Wood Door frame size is 125x90mm with double rebate. Door Hardware Provision as per choice of Architect/client\"s approval. All are complete as per Architect\"s/ Clients approval . Cost ofDoor Hardware like Brass Door closer of suitable specification for heavy door are inclusive in the quoted rates for all doors (approx qty 12 Nos door). |
| 14 | Item No. 10 : S & F ofStainless SteelGrade 304 Handle 600mm long, fancy type, of any colour (as approved by PMG) heavy duty complete all as specified and directed |
| 15 | Item No. 11 : S & F ofStainless SteelGrade 304 SS Hinges 125 mm, heavy duty complete all as specified and directed. |
| 16 | Item No. 12 : S & F ofStainless SteelGrade 304 Tower Bolt 450 mm long, complete all as specified and directed. |
| 17 | Item No. 13 : S & F ofStainless SteelGrade 304Dead Lock and automatic drop down seal are inclusive in the quoted rates for all doors (approx qty 12 Nos door) complete all as specified and as directed. |
| 18 | Fixing and Lifting Arrangement of Stage Curtings |
| 19 | Item No. 14 : Supply Installation Testing and Commissioning of MAIN CURTAINhorizontal sliding arrangement complete with fixing rails, brackets, sliding arrangement & motorized operation complete with runners, master runners, pullies, 3mm steel wire rope, 1 HP motor (Crompton) 2nos., Air breaker contactors (L&T/SIEMENS), 2nos. micro switches for auto stop, 3 nos push buttons for forward, reverse and stop positions.The curtain should be draped to half area when in closed position.Minimum overlap at centre should be 900mm and should be stitched in double gathering Mechanism (Fabric made out ofvelvet curtain 300 to 400 GSM cloth with Fabric) |
| 20 | Item No. 15 : Supply Installation Testing and Commissioning of REAR/MIDDLE CURTAIN - horizontal sliding arrangement complete with fixing rails, brackets, sliding arrangement & motorized operation complete with runners, master runners, pullies, 3mm steel wire rope, 1 HP motor (Crompton) 2nos., Air breaker contactors (L&T/SIEMENS), 2nos. micro switches for auto stop, 3 nos push buttons for forward, reverse and stop positions.The curtain should be draped to half area when in closed position.Minimum overlap at centre should be 900mm and should be stitched in double gathering Fbric(Fabric made out ofvelvet curtain 300 to 400 GSM cloth with Fabric) |
| 21 | Item No. 16 : Supply Installation Testing and Commissioning of WINGS :- Supply Installation testing and commissioning of velvet cloth300 to 400 GSM black fabric as per approved samplefixed over the metal frameworkmetal framework made out of 50 x 50 mm squareMS pipe (medium grade) specification complete. Note : Measurement will be made for external dimensions including heading for payment Fabric |
| 22 | Item No. 17 : Supply Installation Testing and Commissioning of FRILLS :-Supply Installation testing and commissioning of frills in double gathering box pleats stiched out of 300 to 400 GSM valvet fabric,The frill to be fixed from the suspension grid with38 mm dia B class ms pipe suitably hung by mean of 35x4mm MS flat. The pipe & flat to be painted with black enamel paint . |
| 23 | Arboriculture |
| 24 | Item No. 18 : Excavating / Digging out pits of suitable size (but dia not less than 400 mm and depth not less than 500 mm) each pit not exc 0.50 Cum in soft/loose of soil, manually or with using augar/pickxe including removing excavated soil to a distance not exc 50 m and making good the surfaces complete all as specified and directed. |
| 25 | Item No. 19 : Supply only approved each mixed with suitable as well as suffcient manure & chloropyriophos complete all as directed and specified. |
| 26 | Item No. 20 : Supplying and planting of following season flowering healthy plant/sapling of fully young 1 year aged of specified minimum 1 m height in the pits, refiling the pits with prepared mix of earth duly mixed with suitable manure & chlorpyriophos etc in the suitable proportions as complete all as specified and directed. |
| 27 | (a) Rose |
| 28 | (b) Bougainvine cwarf mix colour hybrid |
| 29 | (c) Hibiscus |
| 30 | (d) Plumeria champa |
| 31 | (e) areca palm |
| 32 | (f) bottlel palm |
| 33 | (g) Foxtail palm |
| 34 | (h) Adanium palm |
| 35 | NOTE: (a) Rate for digging for plantation for plant/sapling will be measured and paid seperately(b) Rate for approved earth mixed with suitable manure will be measured and paid seperately |
| 36 | Item No. 21 : Supplying and planting of following seasonal ornamental trees healthy plants of 2 year aged of specified minimum 1.5 m height in the pits, refiling the pits with prepared mix of earth duly mixed with suitable manure & chlorpyriophos etc in the suitable proportions as complete all as specified and directed. |
| 37 | (a) Michelia champa 1.20 mtr minimum height |
| 38 | (b) Night bluming jasmine |
| 39 | (c) Ficus banjaminia |
| 40 | (d) Amal Tar |
| 41 | (e) Tabebuja Roses (savana oka) |
| 42 | (f) Tubebuia avelianedas (pink trumpet) |
| 43 | (g) Cassia fistula (golden shower tree) |
| 44 | NOTE: (a) Rate for digging for plantation for plant/sapling will be measured and paid seperately(b) Rate for approved earth mixed with suitable manure will be measured and paid seperately |
| 45 | Item No. 22 : Supplying and planting of following fruits trees healthy plants of 2-3 year aged of specified minium 1.5 m height in the pits, refiling the pits with prepared mix of earth duly mixed with suitable manure & chlorpyriophos etc in the suitable proportions as complete all as specified and directed. |
| 46 | (a) Mango 3 year agred (MIYAZAKI, RED PALMER, MALLIKA, ALPHANSO) |
| 47 | (b) Water Apply 3 year agred (dalhari, Bell chamba) |
| 48 | (c) Jamun 3 year agred |
| 49 | (d) Sapota (cricket ball) |
| 50 | (e) Guava 2 year agred (VNR, L49, Red diamond) |
| 51 | NOTE: (a) Rate for digging for plantation for plant/sapling will be measured and paid seperately(b) Rate for approved earth mixed with suitable manure will be measured and paid seperately |
| 52 | Item No. 23 : Supply & planting of shrubs/hedges in double row at desired distances of suitable shurbs like durantla, laisa and aclipha (Min height 25 cms) one the prepared formation around the peripheri of the area complete incl necessary trenching to plantation all as specified and directed.Note: (a) Rate for laying of approved earth in including in the items.(b) Rate for approved earth mixed with suitable manure will be measured & paid seperately. |
| 53 | Item No. 24 : Supply & planting of grass readymade like carpet or selected no 1 by dibbing root method on layed approved earth mixed with manure including necessary trenching complete all as specified and directed.Note: (a) Rate for laying of approved earth in including in the items.(b) Rate for approved earth mixed with suitable manure will be measured & paid seperately. |
| 54 | Item No. 25 : Drilling and tapping cast iron water mains (in position) for branch connections of the internal dia of pipe is 15 mm complete all as specified and directed. |
| 55 | Item No. 26 : Supply and Fixing of 20 mm GI tubes \"medium grade\" galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 56 | Item No. 27 : Supply and Fixing of 15 mm GI tubes \"medium grade\" galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 57 | Item No. 28 : S&F of bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 58 | Item No. 29 : S&F of Gun-metal, globe or gate vlaves, 20 mm with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 59 | SCROLL WATER COLLED CHILLING MACHINE WITH MICRO-PROCESSOR BASED CONTROL PANEL |
| 60 | Item No. 30 :SupplyInstallation,testing and commissioningof ScrollScrewWater ChillingM/C of 70 TR( Actual) capacityConusmingnot more than0.72 (IKW/TR ) at 100 % Loadatbelowmentionedoperatingconditionswith R410 A/R407Crefrigerant, / semihermatic// hermaticsealedcompressor, driven by suitable KW Sq. Cage inductionmotorcompletewith watercooled shell& tubecondenser,insulatedshell and tubeflooded chiller, flowswitchesatcondenser & chiller outlet, refrigerant piping,RefrigerantandOil(First Charge), Microprocessor based control panel& accessories etc.( to be supplied by manufacturer of the chilling machine & Factory fitted ) allmountedonM.S. frame.Motorshallbesuitablefor 415 volts ± 10%, 50Hz± 3 %, three phase A.C. supply. |
| 61 | Condenser CDWIN-32.22º C./ 90.00 º F CDW OUT -36.39º C /.97.50 º FChillerCHWIN- 12.22 º C / 54.00 º F CHWOUT-6.66 º C /44.00 º F |
| 62 | Insulationofthechillingmachineshallbedone by manufactureronlyThechillingmachineas described aboveshall bein line with specifications. |
| 63 | Item No. 31 :Supply, installation,testing &commissioning ofEnd Sectioncondenserwater centrifugalpump sets with bronze impeller for condenser water recirculation completewithTEFC Sq. Cageinductionmotor with class\"F\"insulation, mechanical seal etc.conforming to technical specification & as per following parameters: (Company Assembled & Factory Fitted). |
| 64 | Condenser Water Pumps Capacity of each pump (LPM)1059Pump Head (Mt) 25.0 |
| 65 | Proposed KW of Motor 7.5 |
| 66 | Item No. 32 :Supply, installation, testing andcommissioning of End section chilledwatercentrifugalpumpsetswith bronze impeller for chilled water recirculation complete withTEFC Sq.Cageinduction motorwithclass \"F\" insulation, mechanical seal etc. conforming to techinical specification and as perfollowingparameters. Thechilled waterpumps shall include thermal insulation & cladding. (Company Assembled & Factory Fitted) |
| 67 | Primary Chilled Water Pumps Capacity of each pump (LPM)635Pump Head (Mt) 12.0 |
| 68 | Proposed KW of Motor 2.2 |
| 69 | Secondary Chilled Water Pumps |
| 70 | Item No. 33 :Supply,installation,testingandcommissioning ofEnd Secrtion Chilledwatercentrifugal pump sets with bronzeimpellerforchilled waterrecirculation complete withTEFC Sq. Cageinduction motor with class \"F\"insulation, coupling guard,factory fitted mechanicalsealetc. conformingto technical specification & as per following parameters.Thechilled waterpumpsshallalsoincludethecost of thermal insulation and aluminium cladding.Secondary chilled water pumps shall besuitable for operation on adjustable frequency drives & conforming to the specifications of variable speed pumping system (Company Assembled & Factory Fitted) |
| 71 | Variable Speed Pumping System |
| 72 | Item No. 34 :Supply, installation, testingandcommissioningof VariableSpeedPumping system consisting of Three Numbers3.7 KWadjustable frequency drive(AFD) ( Stand alone or integrated with motor for sensorless operations) suitablyinterfacedwithothersystemcomponents,hand / auto macro designedforpumpingapplication,No. of dedicated microprocessor based pump logic controller, parallel pumping softwareduly downloaded,No. of Differential Pressure Sensor/ Transmitters, interfacingamongstall components and compatibility of I/O signals etc complete with other accessories as required. |
| 73 | Capacity of Each Pump LPM635Pump Head (Mt)36.0 |
| 74 | Proposed KW of Motor 7.5 |
| 75 | Item No. 35 :Supply, installation, testing andcommissioning of FRP induced draft Cooling Towerofcapacity 100 TR (HeatRejection Capacity - 3,02,400 K Cal per hour.) complete with FRP water basin, PVC fillings, statically anddynamicallybalancedfan, TEFC motor, suction screen, make up & quick fill arrangement, over flow & drain connection,suitablesteel ladderetc.and conforming to standard specification.Inlet Water Temperature 37.50 °C |
| 76 | Outlet Water Temperature32.00 °C |
| 77 | Item No. 36 :Supplyinstallation , testing andcommissioning of Closed loop expansion tank as per standards & requirements.The tank shall be made of mild steel and has a synthetic rubber membrane. Nitrogen gas or compressed air is filled in space between the membrane and the wall of the tank. The tank should be supplied complete with buster pumps (1W+1S), isolating valve, check valve, drain valve & pressure gauge. Before connecting the tank to water system, the gas pressure should be checked through the charging valve and adjusted according to the requirements, the control panel should also be included. The quoted price shall be inclusive of structural support for the tank. Capacity of tank i 300 lts+ Pumps with N+1 confirgration |
| 78 | Item No. 37 :Supply, installation, testing andcommissioningof PN 10 rated Air Separator made out of MS Sheet as per Specification and Schematic diagram - 300 Ltrs.for Chilled water system |
| 79 | Double Skinned Celing SuspendedAir Handling Units |
| 80 | Item No. 38 :Supply, installation,testing & commissioning of factoryfabricated Double Skinned Chilled Water Air-handling unitCeiling Suspended type fabricated out of extruded aluminium section with 0.8mm pre-plasticized/pre-coated Galvanised steel sheet outside & 0.8mm plain Galvanised steel sheet inside withblower,blower section & Blower shall be DIDW Forward Curved blade from & blower motor TEFC type suitable for operation on 415volts±10%,50 Hz± 5% AC supply, 4/6 Row cooling coil made of Aluminium finned Copper tube( thickness 0.50mm) with coil section,pre-filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90%,polished stainless steel drain pan made out of 22Gsheet duly insulated complete with motor& belt drive package etc.without face & bypass dampers.The AHU panels shallbe insulated with40mm thick &38Kg/m³density PUfoam.The motor&blower assembly shallbe mounted on Aluminium extruded section only.The completeAHUshall conform to standard specification.The face velocity across cooling coil shall be limited to152MPM maxm.The capacity of Air-handlers shall be as follows: |
| 81 | Thefacevelocity across cooling coil shall be limited to 152 MPM maxm.The capacity of Air-handlers shall be as follows:(For AHU No. Please Refer Basic Of Design & AC TenderDrawing )AHUStaticCoolingMotor Coil Area FilterCap. Pr.Coil RowKW SMT CFM mm of WCDeep |
| 82 | 350030 mm 4 Row 2.2 0.65 Pre |
| 83 | 750045 mm 4 Row 3.7 1.39 Pre |
| 84 | Double Skinned Floor Mounted Air Handling Units with Pre Filter |
| 85 | Item No. 39 :Supply, installation, testingand commissioningof factory fabricatedDoubleSkinnedChilledWater Air- handlingunithorizontaltypefabricated out of extruded aluminium sectionconsistingwith 0.8mm pre-plasticized/pre-coated Galvanised steel sheet outside & 0.8 mm plain alvanised steelsheetinsidewithblower,blowersectionand Blower shall be DIDW Forward / Backward Curvedbladefrom and blowermotorTEFCtypesuitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply,6 Row cooling coil made of Aluminium finned Copper tube ( thickness 0.50 mm) withcoilsection,pre - filtersectionwithnonwoven syntheticmediaof10 micronparticlesizewith an efficiencyof90%, polished stainless steel drain pan madeout of 18 G sheet duly insulated complete with motorandbeltdrivepackage etc. withoutface and bypass dampers. The AHU panelsshall be insulated with 40 mm thick & 38 Kg/m³ density PU foam. Themotor & blower assembly shallbemountedon Aluminium extruded sectiononly. The complete AHU shall conform to standard specification.Compatable with Air Ozone System) |
| 86 | Thefacevelocity across cooling coil shall be limited to 152 MPM maxm.The capacity of Air-handlers shall be as follows:(For AHU No. Please Refer Basic Of Design & AC TenderDrawing ) |
| 87 | AHUStaticCoolingMotor Coil Area FilterCap. Pr.Coil RowKW SMTCFM mm of WCDeep |
| 88 | 2000075 mm 6 Row113.71 Pre |
| 89 | Item No. 40 :Supply, installation,testingandcommissioningof GI powder coatedfancoilunitscompletewith fan, 3speedmotor, 3/4 row deepcooling coil,aluminium filterswithfilter box, doublesandwitchedinsulated tray,ballvalve with strainer, balancing valve, copper connection,rotary switch, supporting arrangement,electricalwiringetc. Thefan shall be selected for 12 mm static pressure. The complete fan coil unit shall be in line with the standard specification. The capacity of fan coil units shall be as follows: |
| 90 | 1.5 TR , 600 CFM, 12 mm SP |
| 91 | 2.0 TR , 800 CFM, 12 mm SP |
| 92 | Item No. 41 :Supply, installation,testingandcommissioningof automatic control forFan Coil Units consisting of two way motorised valves with snapeacting motor & thermostat. |
| 93 | 1.5- 3.0TR( 25/32mm dia.) |
| 94 | Item No. 42 : Supply,installation,testingandcommissioning oftwoway motorised valvesdulyinsulated ( 50 mm thick EPS , 20 Kg / meter³ with modulating moterincoolingcoil& heating Coil ofair handlingunits with actuator&electronicmodulatingthermostat with digital display alongwith transformerof following size. |
| 95 | 25 mm dia |
| 96 | 40 mm dia |
| 97 | 65 mm dia |
| 98 | INSULATED CHILLED WATER PIPING ( Expanded Polystrene Insulation) |
| 99 | Item No. 43 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. |
| 100 | Note : The Pipes of sizes 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. |
| 101 | 125mm dia.(50mm thick insulation) |
| 102 | 100mm dia. (50mm thick insulation) |
| 103 | 80mm dia. (50mm thick insulation |
| 104 | 65mm dia.(50mm thick insulation) |
| 105 | 50mm dia.(50mm thick insulation) |
| 106 | 40mm dia. (50mm thick insulation) |
| 107 | 32 mm dia(50mm thick insulation) |
| 108 | 25 mm dia(50mm thick insulation) |
| 109 | INSULATED VALVES |
| 110 | Item No. 44 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequatelyupported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot water circulation as specified |
| 111 | 80mm dia. |
| 112 | 50mm dia. |
| 113 | 40mm dia. |
| 114 | SUB HEAD 2.2 - PIPING & INSULATIONWORK |
| 115 | Item No. 45 : BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. |
| 116 | 80mm dia. |
| 117 | 50mm dia. |
| 118 | 40mm dia. |
| 119 | Item No. 46 : NON - RETURN VALVE with duel plate of C I body SS plates anized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified. |
| 120 | 80 mm dia. |
| 121 | Item No. 47 : Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. |
| 122 | 80mm dia. |
| 123 | 50mm dia. |
| 124 | 40mm dia. |
| 125 | Item No. 48 : Providing and fixing in position the industrial type pressure gauge complete as required |
| 126 | Item No. 49 : Providing & fixing in position the mercury in glass industrial type thermometer complete as required |
| 127 | CONDENSER WATER PIPE |
| 128 | Item No. 50 : Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS ‘C’ class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. |
| 129 | Note:-The Pipes size 150mm & below shall be M.S. ‘C’ classas per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. |
| 130 | 150 mm dia. |
| 131 | 100 mm dia. |
| 132 | 40 mm dia. |
| 133 | 32 mm dia. |
| 134 | VALVES WITHOUT INSULATION |
| 135 | Item No. 51 :Supplying, fixing, testing and commissioning of following sizevalves, gauges and strainers for condenser water circulation as per specifications. |
| 136 | BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O-ring & PN 16 pressure rating as specified. |
| 137 | 150 mm dia. |
| 138 | 100 mm dia. |
| 139 | 65 mm dia. |
| 140 | Item No. 52 : NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as pecified. |
| 141 | 100 mm dia. |
| 142 | Item No. 53 : Supply, installation, testing andcommissioningof Pot - Strainerof the following sizes conformingto standard specification. |
| 143 | 150 mm dia |
| 144 | SUB HEAD 2.2 - PIPING & INSULATIONWORK |
| 145 | Item No. 54 : Supply , installation , testing andcommissioningof condensatedrainwaterpipingofGI \"Medium\" class complete withMedium Class fittings like elbows, tees, reducers bends, MS flanges, supports, welding, painting 25 mm thick EPS insulation etc. asrequiredconformingto standard specifications and offollowing sizes. |
| 146 | 40 mm dia pipe |
| 147 | 50 mm dia pipe |
| 148 | 65 mm dia pipe |
| 149 | Item No. 55 : Supply, installation, testing andcommissioningof auto air vent valve of following sizes:- |
| 150 | 12 mm dia auto air vent valve |
| 151 | DUCTING, GRILLS,DIFFUSER AND INSULATION |
| 152 | Item No. 56 : Supply, installation, balancing and commissioning of factory abricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings andpecifications of following sheet thickness complete as required. |
| 153 | Thickness 0.63 mm sheet |
| 154 | Thickness 0.80 mm sheet |
| 155 | Thickness 1.00 mm sheet |
| 156 | Thickness 1.25 mm sheet |
| 157 | Item No. 57 :Supplying & fixing of powder coated extruded aluminiumSupply Air Grills with aluminium volume control dampers as per specifications. |
| 158 | Item No. 58 : Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required. |
| 159 | Item No. 59 : Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. |
| 160 | Item No. 60 : Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core. |
| 161 | Item No. 61 : Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return actionshall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. |
| 162 | Damper |
| 163 | Actuator |
| 164 | Item No. 62 : Supplying, fixing testing commissioning of volume control dampers with anti smudge ring & removable core. |
| 165 | Item No. 63 : Supplying & fixing of powder coated Linear extruded aluminium Supply / Return Air Grills with aluminium volume control dampers as per specifications. |
| 166 | 150 mm |
| 167 | Item No. 64 : Supplying & fixing of Fresh air intake louvers with bird screen dampers (Aluminium extruded only). |
| 168 | Item No. 65 : Supplying and fixing of acoustic lining of duct with Open Cell cross linked polyethylene density80-100 Kg/m³. Applied by Adhesive, conforming to standard specification. |
| 169 | 10 mm thick open cell XLPE |
| 170 | 15 mm thick open cell XLPE |
| 171 | Item No. 66 : Supply & Installation of Thermal Insulation on Ducts not exposed to sunlight using Physically / Chemically crosslinked polyethylene foam, with factory reinforcedalupet foil facing, with Class O fire properties,with very low fire propagation of < 5.5 and passing E-84 at < 25/50, as per tender technical specification, the density of the foam should be not less than 25-30kg/m3 and the maximum thermal conductivity Kshould be 0.032W/mK@ 23 Deg C , the permeability resistance factor u shouldn\"t be less than 14000.to be applied on Ducts using manufacturer\"s recommendedAdhesive in a blend of Solvents. |
| 172 | 13 mm thick Close cell XLPE |
| 173 | 19 mm thick Close cell XLPE |
| 174 | SUB HEAD 2.4 - ELECTRICAL WORK |
| 175 | CUBICAL PANEL BOARD For |
| 176 | i) 70 TR Actual Water-Cooled Scroll Chilling Machine (3W+1S)ii)7. 5KW CDW Pumps (3W+1S)iii) 2. 25KW P.CHW Pumps (3W+1S)iv)7. 5KW S.CHW Pumps (2W+1S) v) 3.75 KW (100 TR) Cooling Tower(3W+1S) |
| 177 | Item No : 67Supply, installation, testing and commissioning of non draw out Cubical type sectinalised & Compartmentalised floor standing powder coated switchboard of 31 MVAfault capacity at 415 V complete with 4 strip, 250 A capacity AluminiumBus - BarElectrolytic grade,cable alley & supplying&fixingoffollowingswitchgearsasper specifications including connections & interconnections.i) INCOMER |
| 178 | 02 No. -250 A FP MCCBManualDraw out Microprocesserased adjustable protection relays type with overload,short ckt.,earth fault protection release &under voltageprotection, selector switch, 96mm ammeter & 96mm Voltmeter with selector switches,phase indication light with protection fuse,on/off/tripindicatinglight with Protection Fuse. ACB shall be of 50 KA(Icu = Ics).ii) Bus Coupler |
| 179 | 01 No. - 2504Pole MCCBManual Drawoutmanuallyoperated drawouttype Bus Coupler. MCCB shall be of 50 KAiii) Incomers andbuscouplershall be mechanically electricallyinterlockedwith onesetof castlekeyinterlocking system ( 3 locks and 2 keys )interlockedto avoid paralleling ofthe two supplies.OUTGOINGSFor 3 Nos. 70 TR ScrollWater ChillingMachine03 NO. -150 A FP MCCBThermal Maganitic release adjustable type with overload,short ckt.,Protection, on/off /trip indicating lightwith Protection Fuse. |
| 180 | For 3Nos.7.5 KWCondenser WaterPumps.03 No. - 40 A TPMCB with Conforming to BIS Star Delta starter, overload relay, start/stop push buttons,ammeter (0-40A) with three CT, on / off / trip indication lights with protection fuse, single phase preventer.For 3Nos.2. 25 KWP. ChilledWaterPumps.03 No. - 40 A TPMCB with Conforming to BIS Star Delta starter, overload relay, start/stop push buttons,ammeter (0-40A) with three CT, on / off / trip indication lights with protection fuse, single phase preventer. |
| 181 | For 3Nos.7.5KWS. ChilledWaterPumps.03 No. - 40 A TPMCB with Conforming to BIS Star Delta starter, overload relay, start/stop push buttons,ammeter (0-40A) with three CT, on / off / trip indication lights with protection fuse, single phase preventer.For 3 Nos. 3.75 KW - Cooling Towers.03 No. - 40 A TPMCB with Conforming to BIS Star Delta starter, overload relay, start/stop push buttons,ammeter (0-40A) with three CT, on / off / trip indication lights with protection fuse, single phase preventer.Controls & interlocking accessories as Complet withConnection / interconnection required for above switchgears |
| 182 | SUB - PANELS FOR AIR HANDLING UNITS |
| 183 | Item No. 68 : Supply , installation ,testingandcommissioningof Cubicaltypesectionalised& Compartmentalised wall mounted switch board with 4 strip Alunimun Bus Bar suitable capacity, Cable allay etcofof as detailed below & conforming to the specification. Includingconnections & interconnection etc as required. |
| 184 | AHU Sub Panel -Supply Air Blower ( Up to11 KW) |
| 185 | 01 No. - 40 A TPMCB with Conforming to BIS Direct on Line starter, overload relay, start/stop push buttons,ammeter (0-40A)on / off / trip indication lights with protection fuse, single phase preventer.Controls & interlocking accessories as Complete withConnection / interconnection required for above switchgears |
| 186 | POWER & CONTROL CABLING |
| 187 | Item No. 69 : Supply, laying, testing and commissioning of power andcontrolcabling, asper Standard specification including end termination as required.Power Cabling (XLPE) insulated andPVC sheathed, armoured, Aluminium Conductorof 1.1 KV grade on cable trays). |
| 188 | 3.5C x 95 Sq. mm |
| 189 | 3C x 10Sq. mm |
| 190 | 3C x 6 Sq. mm |
| 191 | Earthing Strip / Wires. |
| 192 | Pdg.and fixing 25 x 5 mmG.I. strip along with Cable Tray as required. |
| 193 | Pdg. &fixing 6 SWG GI wire on surface or in recess , along with the exiting cable for loopearthingIncluding connection etc as required. |
| 194 | Supply & laying of rubber mat of size 900 mm & 12 mmthick |
| 195 | Item No. 70 : Supplying and installing following size of perforated pre-painted M.S cable trays with perforation not more than 17.5% in convenient sections,joined with connectors,suspended from the ceiling with M.S suspenders including bolts & nuts,painting suspenders etc as requuired. |
| 196 | 150 mm width x 50 mm depth x 1.6 mm thickness |
| 197 | 300 mm width x 50 mm depth x 1.6 mm thickness |
| 198 | 600 mm width x 50 mm depth x 1.6 mm thickness |
| 199 | SITCof63 AFPMCCBinduly enclour in MS box including complete with connection / interconnection etc. as requiredfor Conforming to Specification for cooling tower |
| 200 | SUB HEAD 3.0 - MECHANICAL VENTILATION SYSTEM |
| 201 | Ventilation fan |
| 202 | Air Qty.=20000 CFM Static Pressure = 25mm WgFan Speed = not exceeding 1450 rpmMotor=12.5 KWFan Dia = 1000 mm (Approx.)Noise level = not exceed 90 db at 1 meter distanceTube Axial Fans as described above. |
| 203 | Fan Sub Panel -Supply Air Blower ( Up to15 KW) |
| 204 | 01 No. - 40 A TPMCB with Conforming to BIS Direct on Line starter, overload relay, start/stop push buttons,ammeter (0-40A)on / off / trip indication lights with protection fuse, single phase preventer.Controls & interlocking accessories as Complet withConnection / interconnection required for above switch gears |
| 205 | NOTE: The AC contractor shall provide fire shunt relay contact in his panel wherever necessary along with auto / manual mode selector switch in the outgoing feederforVentilation&Pressurizationfanetc.to take fire input signal (Potential Free Contact).Cost shall be included in the panel price quoted by him. |
| 206 | Item No. 71 : Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm. |
| 207 | Item No. 72 : Removing excavated material exceeding 250m but not exceeding 500 m and depositing where directed |
| 208 | Item No. 73 : Plain Cement Concrete in foundations, filling & mass concrete D2 1:4:8 (40 mm graded aggregate).OPC replaced with 100 % PPC |
| 209 | Item No. 74 : Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in Cement mortar 1:4 |
| 210 | Item No. 75 : M-25 concrete for RCC workWalls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses |
| 211 | Item No. 76 : Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter |
| 212 | Item No. 77 : S/F TMT bars 10mm dia and over cut to lengths bent to shape required including cranking bending spirally for hooping for columns, hooking ends and bindings withmild steel wire (annealed)not lessthan 0.9 mm dia or securing with clips quality conforming to complete all as specified. |
| 213 | Item No. 78 : S/F TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacersand binders required for columns, hooking ends and bindings with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to complete all as specified. |
| 214 | Item No. 79 : Medium duty precast concrete manhole cover frame & gratings Test Load – 10 MT as per IS 12592 Part – I & IIMHCF-18 |
| 215 | Item No. 80 : Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity1.5 TR. |
| 216 | Item No. 81 : Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.0 KVA |
| 217 | Item No. 82 : Supply and fixing modular AC Box (white) with 3 pin socket two in one, all in one type, single pole and neutral box with one single pole MCB 32 A, 230 Volts inculuding modular metal Box, modular cover plate with frame of 4 modulecomplete all as specified and as directed. |
| 218 | stage light system |
| 219 | Item No. 83 :SITC of3-Way Cinema Screen Speaker System has been specially developed as a cost effective solution for large and extra large cinemas. Frequency Response 45Hz to 20kHzPower Rating LF: 1600W AES, 6400W peak; MF: 150W AES, 1000W peak; HF: 80W AES, 450W peak. Sensitivity LF: 104dB @ 1W/1m; MF/HF: 118dB @ 1W/1. Dimensions (H x W x D) 1808 mm x 893 mm x 760 mm (71.1″ x 35.1″ x 30″). Net Weight 137 kg (302 lb). |
| 220 | Item No. 84:SITC of 2 x 18” (450 mm) long throw weather resistant woofer. Front and rear loaded optimized SIC™ design, High power handling. Frequency Response 35Hz to 200Hz. Power Rating 2000W AES, 8000W peak. Sensitivity 101dB @ 1W/1m. Maximum SPL 134dB continuous, 140dB peak @ 1m. Nominal Impedance 4Ω. Dimensions (H x W x D) 552 mm x 1000 mm x 700 mm. Net Weight 80 kg (176 lb). |
| 221 | Item No. 85 :SITC of Cinema Surround Speaker System is specially designed for immersive sound playback in medium and large cinemas. Frequency Response 100Hz to 18kHz. Power Rating 250W AES, 750W peak. Sensitivity 102dB @ 1W/1m. Maximum SPL 126dB continuous, 132dB peak @ 1m. Nominal Impedance 8Ω. Dimensions (H x W x D) 470 mm x 380 mm x 279 mm. Net Weight 10 kg ( 22 lb). |
| 222 | Item No. 86 : SITC of active crossover designed to maximise the performance of cinema speaker systems. It has 4 balanced inputs and 7 balanced outputs for the left, centre and Right screen channels and one subwooferchannel in a 1U rack space chassis. 24dB/octave Linkwitz Riley configured with low noise OPAMPS and close tolerance components. The additional features include subsonic roll off, delays, CD horn EQ and screen loss equalisation. Externally accessible thumbwheel switches are provided for HF, LF and BM level settings |
| 223 | Item No. 87 : SITC of four channel power amplifier designed and built for applications where sonic transparency and robust high power output capability are the prime criteria. No.Of Channels 4Output Power(per channel) >4 x 480 Watts @ 8&Omega 4 x 820 Watts @ 4&Omega2 x 1380 Watts @ 8Ω in bridge mode. Frequency Response 20Hz - 20kHz, +0/0.5dB.nput Power 1200 Watts. Dimentions 88 mm x 440 mm x 480 mm (3.47\" x 17.3\" x 18.9\"). Net Weight 28.4kg (62.6 lb). |
| 224 | Item No. 88 : SITCof the isolation base, 2 two layer of 19 mm ply with MS support for speaker paltform for the main speaker as per drg. |
| 225 | Item No. 89 : SITC of 16-IN, 16-OUT Digital Speaker Processor2 x 24 back-lit LCD display helps navigate options through its extensive feature set and is also easy to see in dimly lit venues24-Bit A/D converters 96kHz sampling rate and an array of DSP functions that include crossover, delay features, compression, limiting, feedback control features and much more.16 analog inputs and 16 analog outputs, microphone or line, 48V switch per input channel, 24 bit A/D and D/A convertor 48kHz sampling rate 8th order filters for crossover GPIO Extensible Function Feedback suppressor in per input channel AUTO-MIX and MATRIX-MIX 31 PEQ per input and 10 PEQ per output USB, RS232/RS485 connector for centre control . |
| 226 | Item No. 90 :SITC of Male & Female Green Rooms: All WeatherCo-axial Loudspeaker, , 5.5\" Weather Resistant Coaxial Driver, frequency Response (+/-3 dB): 67 Hz - 18 kHz or better. The Sensitivity (SPL / 1 W @ 1 m) > 87 dB . The Maximum SPL @ 1 m >114 dB . Coverage Pattern should be 90° x 90° or better .The Long-Term Power Handling is 80W Continuous, 320W Peak or better , IPX 67 rated ABS Enclosure ,Rust-Free, Zinc Treated Grill - Powder Coated ,Approved |
| 227 | Item No. 91 : SITC of Control Room: All WeatherCo-axial Loudspeaker, , 5.5\" Weather Resistant Coaxial Driver, frequency Response (+/-3 dB): 67 Hz - 18 kHz or better. The Sensitivity (SPL / 1 W @ 1 m) > 87 dB . The Maximum SPL @ 1 m >114 dB . Coverage Pattern should be 90° x 90° or better .The Long-Term Power Handling is 80W Continuous, 320W Peak or better , IPX 67 rated ABS Enclosure ,Rust-Free, Zinc Treated Grill - Powder Coated , Approved. |
| 228 | Item No. 92 : SITC of High PerformanceAmplifier 3300W (1650 W X 2 channels @4 ohm); THD < 0.02%; damping factor > 400; inbuilt Sensitivity Selection - High Pass Cut Off - Stereo, Bridge, Parallel Switch, Signal to Noise Ratio (1 kHz, 8 Ohms)- 105 dB . |
| 229 | Item No. 93 : SITCof Software Controlled Digital DSP with below Specifications:-Number of Inputs - 4,Number of Outputs - 8,Input Impedance - 12kΩ unbalanced, 24 kΩ balancedCMMR - >45 dBAdjustable Delay - 1 second / input & 1 second / outputApproved . |
| 230 | Item No. 94 : SITC of 8\" In-ceiling Co-axial Loudspeaker Frequency Response (-3 dB)60 Hz - 20 kHz Nominal Impedance 8 Ohms or 100/70 V Enclosure Dura-light ABS Enclosure Diameter 16.1\" Frequency Range (-10 dB) 52 Hz - 20 kHz Coverage Pattern 135° ConicalGrill Quick Fit Low Reflection Metal Grill 10\" Rated Power 75W Continuous, 300W Peak LF Driver Kevlar Woven 8\" Coaxial Driver - MG45Maximum SPL 113 dB HF Driver1 x 1-inch compression driver, coaxial center-firingSensitivity 91 dB Transformer Taps 60W, 30W, 15W - 100 / 70 V Approved. |
| 231 | Item No. 95 : SITCof 350 W 6-Zone Mixer Amplifier, 6-inputs, 70/100V power amplifer 3 mic inputs, 1 aux input with individual gain pots Ideal for commercial installations Class-H, Ergonomic 2U designIndependent Bass and Treble controls Supports 70V and 100V distributed audio systems Priority EMC mic, 12V phantom power. Supports 24V DC Approved. |
| 232 | Item No. 96 : SITC of Speaker Cable – 4.0 Sqmm (128/0.20mm) x 2 core cable ATC copper conductor PVC insulated, core twisted, outer jacketed with Vasiform Type PVC Sheath. |
| 233 | Item No. 97 : SITC of Speaker Cable – 2.5 Sqmm (80/0.20mm) x 2 core cable ATC copper conductor PVC insulated, core twisted, outer jacketed with Vasiform Type PVC Sheath. |
| 234 | Item No. 98 : SITC of 18 AWG microphone cable (24/0.20mm) x 2 core ATC copper conductor, PE insulated, core twisted in a circular form, Inner sheathed with moisture Proof Polymer, braid shielded (80%) with ATC copper, outer Jacketed with Matt finish Rugged Flexible PVC. |
| 235 | Item No. 99 : SITC of 24 Pair Snake Microphone Cable. |
| 236 | Item No. 100 : SITC of Customized Floor Box with 4x Mic In, 1x Speaker Out and 1x Power Socket. |
| 237 | Item No. 101 : SITC of for Auditorium, bulk connectors such as XLR (Male & female), RJ-45, Speakon, Phono, Stereo Jack, velcro tape, cable ties etc as per site requirement. |
| 238 | Item No. 102 : SITC ofof 42 U Equipment rack to house all rack mountable equipment, with internal wiring, front glass door,heat dissipation fans,power distribution units etc.complete with standard accessories as required. |
| 239 | Sound System |
| 240 | Item No. 103 : SITC of3-Way Cinema Screen Speaker System has been specially developed as a cost effective solution for large and extra large cinemas. Frequency Response 45Hz to 20kHzPower Rating LF: 1600W AES, 6400W peak; MF: 150W AES, 1000W peak; HF: 80W AES, 450W peak. Sensitivity LF: 104dB @ 1W/1m; MF/HF: 118dB @ 1W/1. Dimensions (H x W x D) 1808 mm x 893 mm x 760 mm (71.1″ x 35.1″ x 30″). Net Weight 137 kg (302 lb). |
| 241 | Item No. 104 : SITC of 2 x 18” (450 mm) long throw weather resistant woofer. Front and rear loaded optimized SIC™ design, High power handling. Frequency Response 35Hz to 200Hz. Power Rating 2000W AES, 8000W peak. Sensitivity 101dB @ 1W/1m. Maximum SPL 134dB continuous, 140dB peak @ 1m. Nominal Impedance 4Ω. Dimensions (H x W x D) 552 mm x 1000 mm x 700 mm. Net Weight 80 kg (176 lb). |
| 242 | Item No. 105 : SITC of Cinema Surround Speaker System is specially designed for immersive sound playback in medium and large cinemas. Frequency Response 100Hz to 18kHz. Power Rating 250W AES, 750W peak. Sensitivity 102dB @ 1W/1m. Maximum SPL 126dB continuous, 132dB peak @ 1m. Nominal Impedance 8Ω. Dimensions (H x W x D) 470 mm x 380 mm x 279 mm. Net Weight 10 kg ( 22 lb). |
| 243 | Item No. 106 : SITC of active crossover designed to maximise the performance of cinema speaker systems. It has 4 balanced inputs and 7 balanced outputs for the left, centre and Right screen channels and one subwooferchannel in a 1U rack space chassis. 24dB/octave Linkwitz Riley configured with low noise OPAMPS and close tolerance components. The additional features include subsonic roll off, delays, CD horn EQ and screen loss equalisation. Externally accessible thumbwheel switches are provided for HF, LF and BM level settings. |
| 244 | Item No. 107 : SITC of four channel power amplifier designed and built for applications where sonic transparency and robust high power output capability are the prime criteria. No.Of Channels 4Output Power(per channel) >4 x 480 Watts @ 8&Omega 4 x 820 Watts @ 4&Omega2 x 1380 Watts @ 8Ω in bridge mode. Frequency Response 20Hz - 20kHz, +0/0.5dB.nput Power 1200 Watts. Dimentions 88 mm x 440 mm x 480 mm (3.47\" x 17.3\" x 18.9\"). Net Weight 28.4kg (62.6 lb). |
| 245 | Item No. 108 : SITCof the isolation base, 2 two layer of 19 mm ply with MS support for speaker paltform for the main speaker as per drg. |
| 246 | Item No. 109 : SITC of 2-Way Passive Speaker consists of 2 x 12” low frequency driver in conjunction with 1.75″ voice coil high frequency driver of high sonic quality and dynamic range.90° horizontal and 40° vertical pattern control horn exhibits uniform HF response throughout the cinema auditoriumFrequency Response 50Hz to 20kHz, Power Rang 800W AES, 2400W peak Sensitivity 100dB @ 1W/1m, Maximum SPL 127dB continuous, 133dB peak @ 1m, Nominal Impedance 4ΩCrossover 1.2kHz Passive, low loss air core inductors and MKP capacitors Finish-Black impact resistant structured coating Enclosure 15 mm Birch Plywood direct radiator vented enclosure with mounting options, Grill Acoustically transparent perforated steel with foam backing complete with MS support accessories. |
| 247 | Item No. 110 : SITC of 2-Way Cinema Surround Speaker System,wall mounng with a 15° downward ltFrequency Response 60Hz to 20kHz Power Rang 400W AES, 1600W peak Sensivity 97dB @ 1W/1m, Maximum SPL 123dB connuous, 129dB peak @1m Nominal Impedance 8Ω Low Frequency Driver 12\" (308 mm) Low-Mid driver, High Frequency Driver 1.75\" (44 mm) voice coil compression driver mounted on 90° x 40° horn, Crossover 1.3kHz Passive, low loss air core inductors and MKP capacitors, Dispersion 90° horizontal, 40° vercal Finish Black impact resistant structured coang Enclosure15 mm MDF direct radiator vented enclosure Grill Acoustically transparent black woven fabric with complete MS support accessories |
| 248 | Item No. 111 : SITC of high sensitivity, high power 8″ full range driver with well defined directivity Frequency Response 65Hz to 18kHz Power Rating 250W AES, 750W peak, Sensitivity 94dB @ 1W/1m, Maximum SPL 117dB continuous, 123dB peak @ 1m Nominal Impedance 8Ω, Transducers 8″ (200 mm) dual cone full range driver, Dispersion 90° conical Finish Black impact resistant structured coating Enclosure 15 mm MDF direct radiator vented enclosure Grill Acoustically transparent black woven fabric complete with MS support accessories. |
| 249 | Item No. 112 : SITC of surround subwoofer 18” driver is loaded in a direct radiator bass-reflex enclosure subwoofer. It has a 3” high temperature stabilized voice coil for high power handling and reduced power compression. The specially treated cone is weather resistant and can withstand extremely severe climatic conditions. The large port area reduces turbulence at full power output and low frequencies. Frequency Response , 30Hz to 200Hz Power Rating 600W AES, 2400W peak, Sensitivity 98dB @ 1W/1m, Maximum SPL 125.5dB continuous, 131.5dB peak @ 1m, Nominal Impedance 8 Ω, Transducers 1 x 18″ (455 mm) long throw weather resistant woofer Finish Black impact resistant structured coating, Connector Push type binding post, cable upto 4 mm diameter, Enclosure 18 mm MDF direct radiator vented enclosure, Subsonic Filter 30Hzhigh pass 18dB/octave slope complete with MS support accessories |
| 250 | Item No. 113 : SITC of Speaker Cable – 4.0 Sqmm (128/0.20mm) x 2 core cable ATC copper conductor PVC insulated, core twisted, outer jacketed with Vasiform Type PVC Sheath. |
| 251 | Item No. 114 : SITC of Speaker Cable – 6.0 Sqmm (128/0.20mm) x 2 core cable ATC copper conductor PVC insulated, core twisted, outer jacketed with Vasiform Type PVC Sheath. |
| 252 | Item No. 115 : SITC of 18 AWG microphone cable (24/0.20mm) x 2 core ATC copper conductor, PE insulated, core twisted in a circular form, Inner sheathed with moisture Proof Polymer, braid shielded (80%) with ATC copper, outer Jacketed with Matt finish Rugged Flexible PVC. |
| 253 | Item No. 116 : SITC of for Auditorium, bulk connectors such as XLR (Male & female), RJ-45, Speakon, Phono, Stereo Jack, velcro tape, cable ties etc as per site requirement. |
| 254 | Item No. 117 : SITC of of 42 U Equipment rack to house all rack mountable equipment, with internal wiring, front glass door,heat dissipation fans,power distribution units etc.complete with standard accessories as required. |
| 255 | Item No. 118 : Blank |
| 256 | Item No. 119 : Blank |
| 257 | FURNITURE ITEMS |
| 258 | Item No. 120 : SUPPLY AND FIXING OF AUDITORIUM CHAIRS WITH PUSHBACK MECHANISM & AUTO TIP-UP |
| 259 | Item No. 121 :Auditorium Mild Back Chair with cupholder and bolts 12 Main+ 88 add on Supply and placing auditorium chair size is : 980mm W:525 mm D; 560mm construction seat & back understructure are made in moisture content shall be less than (10-12)%. Thicness of plywood used (mm) shall be 12mm grade is 303 indian standard for commercial (common) and moisture proof plywood (tentative). framing are made in metal should be finishing with epoxy polyester black powder coated to the thickness of 50-60 microns (1/5 micron) chair upholstered in standard high resilience polyurethane molded pu foam having density 40 +/-5 laminated with fabric - polyester. chair have common sharng arms made in plastic armrests shall be high impact injection molded polypropylene plastic in black colour with cupholder arms. full plastic seat shell formed to fit the contour of the body when in the sitting position. the multiple curves give the spectator long time support. The waterfall at the front of the cushion reduces pressure points. The seat bottom and seat-lifting mechanism is totally enclosed by an injection molded polypropylene plastic seat shell in black colour unique texture Drgs – TP |
| 260 | Item No. 122 :Auditorium Mild Back Chair with cupholder and bolts 51 Main+ 449 add on Supply and placing exclusive premium fabric modernist classic design auditorium chair size is H: 980mm W:525 mm D; 560mm construction seat & back understructure are made in moisture content shall be less than (10-12)%. Thicness of plywood used (mm) shall be 12mm grade is 303 indian standard for commercial (common) and moisture proof plywood (tentative). framing are made in metal should be finishing with epoxy polyester black powder coated to the thickness of 50-60 microns (1/5 micron) chair upholstered in standard high resilience polyurethane molded pu foam having density 40 +/-5 laminated with fabric - polyester. chair have common sharng arms made in plastic armrests shall be high impact injection molded polypropylene plastic in black colour with cupholder arms. full plastic seat shell formed to fit the contour of the body when in the sitting position. the multiple curves give the spectator long time support. The waterfall at the front of the cushion reduces pressure points. The seat bottom and seat-lifting mechanism is totally enclosed by an injection molded polypropylene plastic seat shell in black colour unique texture Drgs – TP |
| 261 | Item No. 123 :Sofa set 04 Seater (02+02 Seater) Supply and placing in Potision of 2 seater modernist classic desigh jesse sofa sku : jesse/2 size : 1320mm(I) x 860mm(d)x 830 mm (h), Material: premium leatherette / style : contemporary colour : green-advo green / finish : matte. Supplying and placing two seater exclusive premium leatherette modernist classic desigh louge seating sofa size is 1200mm (I) x 720mm (d)x 845mm(h) with solid wood framing makes it warp and scratch resistant, comfortable seat depth & height designed keeping modern indian lifestyle in mind, wrapped in buttery - soft premium leatherette / classic button-tufting, the panelled back and solid wooden armrests encourage lounging, designed with modernity & elegance, choose the option that suits your home. Combination construction structure are made in moisture content shall be less than (10-12)% thickness of plywood used (mm) shall be 12 mm grade is 303 indian standard for commercial (common) and moisture proof plywood (tentative). structure frame shall be constructed from solid wood wooden framing is highly durable. |
| 262 | the seat & back structure shall be covered by p.u. foam fixed with adhesive glue, the frame shall be padded with high resilience polyurethane foam having 40 +/-5 density in seat 40mm thik, 40mm thick back foam having 40 +/-5 desity foam used, seat & back structure shall be covered with in green-advo green colour, it complements the modish legs are made by squre shape in solid wood material, (seat: 440mm (h), back height@ 470mm), The seller/ company should be NABCB CERTIFIED ISO-9001:2008, ISO-9001:2015, ISO-14001:2015, OHSAS-18001:2007. OTHER CERTIFICATIONS : GREEN PRO, indian design mark, AIOTA, FSC & SEDEX. The bidder should also be a member of BIFMA and One or more products of the OEM should be certified as BIFMA compliant and an official link/screenshot of the product listing must be provided. Drgs – TP |
| 263 | Item No. 124 : Chair Revolving Executive type Dimension: The Base pedestal assembly of chair computer shall be of dis 700mm and 1060 mm high. Discription: The chair revolving shall be high back type with push back and tilt mechanism of hydraulic base with PU soft arms. The padestal assembly shall be provided with injection moulded in black 30% glass filled nylon. A 10.5mm dia forged bright Zinc plated MS castor pin is of press fitted into each prong for holding the castors. The seat and back of the chair computer shall be made of 12mm thick hot pressed plywood upholstered with fabric and moulded polyurethane foam. The back form shall be designed with contour lumber support for extra comfort with PVC lipping allround. The back rest shall be adjustable and consist of drop lift mechanism and shall be adjusted in the insert. It shall be scratch and weather resistant. Rest all as per drg and as per sample approved by BSO/GE. Finish: Pre treated with epoxy powder coated oven baked with ivory white color/white/warm greyDrgs – TP |
| 264 | Item No. 125 : Table Office Clk Steel: Overall size shall be 1200mm long, 410mm wide and 760mm wide and 440mm deep. The base shall be of 25 mm square tube of 1.6mm wide thickness. Legs shall be joined in short sides with 25mm square tube of wide thickness 1.6mm a long stiffener joining short stiffeners shall be provided the middle of short stiffeners. The top of legs shall be joined in short side with 25 mm square tube of wall thickness 1.6mm . on right side, when viewing the table, three drawers shall be provided of 110mm wide. the total height of drawers shall be 430mm and 440mm deep. the drawers shall be made of 1mm thick mild steel sheet. 25mm square mild steel tube 1.6mm wall thickness stiffeners shall be provided for the drawers. The drawers shall run smoothly over one another, the top of table shall be of 19mm thick MDF board commercial over which 1.5mm thick plastic aminated sheet shall be fixed. The standard PVC edging shall be provided to all round thedging of top of table PVC/hard rubber toes shall (Drgs – 381) |
| 265 | Item No. 126 : Almirah Small Steel With Shelves : Dimension: Overall size shall be 1270mm high, 765mm wide and 440mm deep. The base shall be made of two numbers mild steel sheet channel base welded to bottom of almirah and shall be 100mm high. Specifications: Mild steel sheet shall be 1mm thick for channel base. The base channel shall be welde at 50mm from each and of 765mm op, sides, back bottom and front of almirah shall be of almirah shall be of 1mm thick mild steel sheet. Three shelves equally spaced making four compartments will joints and welding, fixing shall be done according standard workmanship |
| 266 | LOCKING DEVICE: The locking device shall be three way locking device and shall also be provided with decorative key plate. take of lock-Harrison/Godrej/Linkor equivalent.HANDLE: A steel chromium plated handle 100mm long shall be provided to the shutter. FINISH: All steel csurfaces exposed to view when placed in position shall be painted with two coats of sliver hammer paint over a coat of primer th spray machine after preparation of surfaces. Rest all as per drgs. (FD-1032) |
| 267 | Item No. 127 : Rack Steel (1830mm x 760mm x 1905mm) Overall size for two units shall be 1830mm long, 760mm wide and 1905mm high. Mild steel angle iron 30mm x 30mm x 3mm shall be used in ners and in middle for two units as vertical support. The rack shall be open from all sides. Mild steel shett 1.25mm thick shall be provided to helves (including top). all steel and iron surfaces exposed to view when placed in position shall be painted with two coats of anamen paint a coat of primer after preparation of surfaces as directed by engineer-in-charge. painting shall be done with spray machine. all as shown drawing and as directed.Drgs : FD- 129(M) |
| 268 | Item No. 128 : Stool Revolving (Adjustable) steeloverall size shall be 455mm dia and 600mm high four legs of 25mm dia mild sheet pipe legs made to shap of thickness 1.6mm irrespective of what is shown on drawing. 12mm dia mild steel bar ring shall be provided at 150mm from bottom joining four legs as show on drawing. Two cast iron discs shall be provided at top of legs and at 100mm top of legs as shown on drawing and fixed to legs with 6mm dia bolt. 25mm dia threaded steel bolt 255mm long fixed with 6mm thick steel plate 100mm dia and top of 25m dia threaded bolt shall be provided as shown on drawing the padded seat shall be fixed on 6 mm thick, 100mm dia steel plate with scren for which four number holes are provided in steel plate. Padded seat shall be 38mm dia, the bottom of padded seat shall be 30mm soft wood over which a layer of coir shall be provided to give proper shape as shown on drawing. |
| 269 | hessian cloth shall be provided to cover the layer of coir and under the soft wood padded seat. A layer of cotton shall be provided and covered with rexene cover alround the top and bottom to form the padded seat. All steel surfaces exposed to view when placed in position shall be given two coats of enamel paint over a coat of primer after preparation of surfaces. Hard rubber/PVC toes ahsll be provided to the bottom of legs. All as shown on drawing.(FD-354) |
| 270 | Item No. 129 : Recepticle PVCDIMENSION/CAPACITY:The recptacle shall be of capacity 40ltrs DESCRIPTION: The body of receptacle Pvc shall be made up of thick polymer plastic of thickness not less than 5mm, provided with swivel lid and steel handles on both sides as shown in drg. (FD/E6/MAP/13) |
| 271 | Item No. 130 : Lecture stand/Compodiumoverall size shall be 970mm wide and 1220mm high. Two upright of mild steel rectangular tube of 75mm x 25mm of 1202 mm high shall be provided in rear side and shall be 635mm apart. The two upright shall be joinded with bottom, middle and top rails with 75mmx50mm mild steel tube of wall thickness 1.6mm and shall be form the part of bottom rails and join the long side of bottom rail of size 785mm long, 75mm x 50mm mild steel tube of wall thickness 1.6mm The front base below bottom rails shall be of 785mm long and 125mm x 50mm mild steel tube of wall thickness 1.6mm and this shall be joined with rear uprights with sides of base which shall be 430mm long 125mmx50mm mild steel tube of wall thickness 1mm. Two support of angle iron shall be provided to the bottom rails owards sides of 150mm long over which 1.6mm thick mild steel foot rest shall be fixed. foot rest shall be 635mm long. |
| 272 | The two sides rails at top fixed and 170mm from buttom shall be 505mm long 75mm x 50mm mild steel tube of all thickness 1.6mm and shall form the part of top rails and jon the long side of top rails and join the long side of top rail of size 920 mm long 75mmx50mm mild steel tube of wall thickness 1.6mm sloping upright support shall be provided between top rails, middle rail and bottom rails in the front two corners. The sloping supports of 25mm square mild steel tube of wall thickness 1.6mm shall be welded to sloping upright in the front two corners.To sloping supports of 25mm square mild steel tube of wall thickness 1.6mm shall be welded to sloping upright Supports for making shell which shall have 12mm thick pre laminated MDF BOARD irrespective of what is shown of drawing. |
| 273 | Another horizontal shell 230 mm below the top shelf shall be provided by welding 25mm square mild steel tube of wall thickness 1.6mm over which 10mm thick pre-laminated MDF BOARD shall be fixed as shown on drawing front and sides of desk stand lecture shall be convered with 12mm thick pre laminated particleboard teak veneer shade. 18mm thick pre-laminated MDF BOARD teak veneer shade shall be provided at top . Horizontal top shall be 970mm 185mm and sides shall be 485mm x 110mm. Al edges of pre-laminated MDF BOARD remained exposed shall be covered with PVC edging as per the size of board edging. One tube light 600mm long and with proper electric connection concealed in such away the same is not visible from outside shall be provided as directed by Engineer-in-charge. all steel surfaces exposed to view when placed in position shall be given two coats of enamel paint over a coat of primer with spray machine after preparation of steel surfaces. (FD-1022) |
| 274 | Aluminium Powder coated door(Fire proof door) |
| 275 | Item No. 131 : ACOUSTIC DOOR Supply Installation Testing and Commissioning ofSystems Double leaf Wooden Acoustic Fire Door, 55mm thick, STC 45. with theAcoustic Property and 2 Hours Fire rated As per confirming IS :3614(Part-II) & BS:476 (Part 20&22) Department of Industries and Commerce, Haryana. Acoustic Fire Door having infill of Rockwool 64kg/ M3 density, Sandwiched between Two Calcium Silicate Boards without asbestos, Brucite and Meerschaum having a density not more than 1150kg/ M3 and Fire rated Ply both side with heat activated intumescent fire seal strip of size 10x4mm and EPDM Gaskets around the frame are used to enhance acoustic properties. 1mm thick Mica laminates facing on both sides in desired shade and colour. Hard Wood Door frame size is 125x90mm with double rebate. Door Hardware Provision as per choice of Architect/client\"s approval. All are complete as per Architect\"s/ Clients approval . Cost ofDoor Hardware like Brass Door closer of suitable specification for heavy door are inclusive in the quoted rates for all doors (approx qty 06 Nos double door). |
| 276 | Item No. 132 : S & F ofStainless SteelGrade 304 Handle 600mm long, fancy type, of any colour (as approved by PMG) heavy duty complete all as specified and directed. |
| 277 | Item No. 133 : S & F ofStainless SteelGrade 304 SS Hinges 125 mm, heavy duty complete all as specified and directed. |
| 278 | Item No. 134 : S & F ofStainless SteelGrade 304 Tower Bolt 450 mm long, complete all as specified and directed. |
| 279 | Item No. 135 : S & F of Stainless Steel Grade 304Dead Lock and automatic drop down seal are inclusive in the quoted rates for all doors (approx qty 06 Nos Double Door) complete all as specified and as directed. |
| 280 | Central Air Conditioning |
| 281 | Item No. 136 : Design, Vetting, supply, installation, testing & commissioning of Central air conditioning plant (for existingAuditorium building of 600 Seating capacity ) withWater cooledChiller Plant of min Capacity 140 TR (02 Nos of half capacity), AHUs,FCUs, Electric Hot water Generator set, Expansion tank for chilled water and Hot water, Humidifiers, water pump sets( min 2W+1S)of suitable type and capacity for chilled water ,condenser , hot water generator , FRP Induced Draught cooling towers(1W+1S), ducting and Insulation for duct and pipings . Electrical Panels and cables of suitable size for Chiller ,AHU Panels,Hot water Generator,any type of Pumps and any other electrical equipments shall deemed to be included in the quoted rates. Cable tray, Water piping for condenser, chiller hot water generator etcwith strainer,all types of valves and vents,Piping Accessories ,Temperature guage,Pressure guage, Dampers/fire proof damper, diffusers and grills, Air curtain, earthing,ducting sheet , associated civil work,plumbing work and electrical work shall demed to be included in the quoted rate.The designing and installation of Central AC Plant shall be as per ASHRAE/ISHRAE standards , relavant IS specification and best practices for auditorium bldgs. |
| 282 | Any other Technical items which is required for proper/efficient installation of HVAC system as per standard norms and as specified in tender shall deemed to be included in the quoted rates.Design of Central AC Plant to be submitted to the dept duly vetted by IIT/NIT/any govt engg college after 30 days of acceptance of the tcontract.Note:1(I) Design of energy efficient central air conditioning plant based on inside & outside conditions inside conditions as per given data sheet attached in PS. The design shall meet relevant ASHRAE/ISHRAE norms and code requirements and should as per latest IS practices. It should included the followings:-(a) Data based heat load calculations for all weather seasons .(b) Duct drawing showing different sizes of ducts air flow details, incl fire dampers and air dampers.(c) Chiller water piping / condenser water pipingetc drawings including valves, vents ,strainer, drains etc .(d) Layout schematic line diagram of LT control panel suitable for the plant showing all the details such as main incoming, outgoing and their type, capacities, qty, alongwith connected measureing instrument/meters, indication lamp, starters, MCB/ MCCB/ isolator literature of various components.(e) Specification/description of equpeiment and other materials/items with technical literature of various components. |
| 283 | (f) Line plan of plant AHU showing various eqpts/items with dimensions of various eqpts/items with specific working clearances between eqpts to eqpts and from walls, after due consideration of existing doors and windows.(g) Schedule of item/description of equipment of all items with accounting unit. Qty and particular specification etc.(h) Full description of item/eqpt of schedule as per recommended brands/makes in the Tender.(i) Inside design conditons are required to be maintained irrespective of minor variations in outside conditons throughout the year as per desired conditions as per PS data sheet .(j) Contractor will submit detailed Qty with line plan which shows the all type of valves,pumps, pipe lines, Chiller,AHU, Cooling Tower,Expansion tank etc. |
| 284 | Note2: (a) Contractor should submit 2 Nos CD showing detailed design with description/specfification complete alongwith heat load calculation (For summer, winter & monsoon design, drawings, bill of quantities and four Nos hard copies.(b) Outside design conditons at Jabalpur can be obtained from concerned metrological authorities. (c) Contractor will develop the soft copy of all the drawings required for the work on the basis of hard copy/line plan of the project. (d) Design folder duly incorporating above design details, layout plans and specifications incl BOQ of the items shall be submitted by the contractor duly bound 3 hard copies and CDs after vetting from IIT/NIT/ any Govt Engineering Collegefor the acceptance by the Rep of accepting officer before execution.(e) The work of Air conditoning shall be carried out by a specialist agency having past experience. (f) Noise level (Sound pressure) should not exceed the permissible limts.(g) Testing includes phase-I 24 Hrs continuous after completing the main workand phase-II 72 Hrs continuous for all three seasons after isssuing completion ofPhase- I by the IEM . (h) Any modification/alteration done for ducting and piping in the building, the Contractor shall make good the damage done for the same. |
| 285 | Item No. 137 : Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR inverter type incl necessery connection cable, copper tubes and stand with MS bolts complete all as specified and directed. |
| 286 | Item No. 138 : Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA. |
| 287 | Item No. 139 : Supply and fixing modular AC Box (white) with 3 pin socket two in one, all in one type, single pole and neutral box with one single pole MCB 32 A, 230 Volts inculuding modular metal Box, modular cover plate with frame of 4 modulecomplete all as specified and as directed.Make- Havells cat no. DHDMCSN0251016 or equivalent make specified in PS. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy