Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 26-04-2025 | Corigendum | Date | 19-05-2025 |
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils |
| 2 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 3 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). |
| 4 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 5 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (\"Original producers\" who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 6 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc.Up To Plinth Level |
| 7 | Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design MixProviding M-25 grade concrete by using min 410 kg of cement per cum instead ofM-20 grade design mix.Up To Plinth Level |
| 8 | Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. |
| 9 | Banking excavated earth in layers not exceeding 20cm. in depth breaking clods watering, rolling each layer with 1/2 tonne roller, or stone or steel rammers, and rolling every 3rd and top- most layer with power roller of 8-10 tonne capacity and dressing up in embankments for roads, flood banks marginal banks, and guide banks etc. lead up to 50 Mtr. and lift up to 1.5 Mtr. All kinds of soils |
| 10 | Random rubble dry stone Kharanja under floor. |
| 11 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. |
| 12 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. Add extra for centering and shuttering work in superstructure above floor five level for each four flooror part thereof . |
| 13 | Columns, pillars, posts and struts etc. |
| 14 | Columns, pillars, posts and struts etc. |
| 15 | Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M20 grade Nominal Mix / Design MixProviding M-25 grade concrete by using min 410 kg of cement per cum instead ofM-20 grade design mix. |
| 16 | Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M20 grade Nominal Mix / Design MixProviding M-25 grade concrete by using min 410 kg of cement per cum instead ofM-20 grade design mix. Add extra for RCC work in superstructure above floor five level for each four flooror part thereof . |
| 17 | Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M25 grade Nominal Mix / Design Mix Providing M-25 grade concrete by using min 410 kg of cement per cum instead ofM-20 grade design mix. |
| 18 | Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M25 grade Nominal Mix / Design Mix Providing M-25 grade concrete by using min 410 kg of cement per cum instead ofM-20 grade design mix. |
| 19 | Half brick masonry in Superstructure , above plinth level upto floor Vlevelusing bricks of designation 75 Cement mortar 1 : 4 (1 cement : 4 coarse sand) Add extra providing and placing in position 2 Nos. ,6mm Ø M.S. barat every thirdcourse of half brick masonry . |
| 20 | Half brick masonry in Superstructure , above plinth level upto floor Vlevelusing bricks of designation 75 Cement mortar 1 : 4 (1 cement : 4 coarse sand) Add extra providing and placing in position 2 Nos. ,6mm Ø M.S. barat every thirdcourse of half brick masonry . Add extra for brick work in superstructure above floor five level, for each four floors or part thereof. |
| 21 | Brick work with clay flyash F.P.S. brick(IS 13757- 1993 ) of class designation 75 in superstructureaboveplinth level upto floor five level in :Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 22 | Brick work with clay flyash F.P.S. brick(IS 13757- 1993 ) of class designation 75 in superstructureaboveplinth level upto floor five level in :Cement mortar 1 : 6 (1 cement : 6 coarse sand) Add extra for brick work in superstructure above floor five level, for each four floors or part thereof. |
| 23 | Providing and fixing in cement sand mortar 1 : 4 single paitam(rebated) stone doors windows and ventilator frames ofapproved quarry : Size 100 x 60mm Profile C |
| 24 | S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws not exceeding 150mm distance at all heights with all lead and lift with scafolding. |
| 25 | Plaster on new surface on walls in cement sand mortar 1:4 including racking of joint etc. complete fine finish :Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.20mm thick. |
| 26 | Plaster on new surface on walls in cement sand mortar 1:4 including racking of joint etc. complete fine finish :Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 20mm thick. |
| 27 | 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) |
| 28 | Extra for plastering done on moulding cornices or architraves including neat finish to line and level:In two coats |
| 29 | Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm |
| 30 | Providing non slip grooves to granite/ kota stone flooring, counters, vanities etc. using groove cutter V type including machine polishing to groove to give high gloss finish etc. complete as per design approved by engineer in charge |
| 31 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour)1501 Cm2 to 3600 Cm2 Tiles |
| 32 | P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. size600 mm X 600 mm |
| 33 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). size450 mm X 450 mm |
| 34 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure \"A\":35 mm thick .Decorative teak veneer both side |
| 35 | Extra for providing external lipping with 2nd class teak woodbattens 6 mm minimum depth on all edges of shutters (over all areaof door shutter to be measured) Over item no. 8.13. |
| 36 | Providing & Fixing mica of approved make for inner/outerside of shutters with fevicol & nails complete as per approvedby engineer in charge. 0.6mm thick mica |
| 37 | Applying priming coat : With ready mix pink or gray primer of approved brand andmanufacture on wood work hard and soft wood. |
| 38 | Providing and fixing cow catcher made of R.S. joist angleschannels MS rounds including cutting welding and fabricationwith priming coat of red oxide (as per design). |
| 39 | Making grooves as per design in plaster 10mm to 20mm wide. |
| 40 | Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completeNew Plastered Surface (three or more coats) |
| 41 | Distempering with oil bound washable distemper of approvedbrand and manufacture to give an even shade including allscaffolding:New work (two or more coats) over and including scrappingandprimingcoatwithcement primer. |
| 42 | Painting exterior surface ofWallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect including scaffolding and safety provision . New Work |
| 43 | Providing & laying Chequered terrazzo tiles of approved make 22mm thick with marble chips of size upto 6mm, in floors, jointed with neat cement slurry mixed wit pigment to match the shade of tiles including rubbing and polishing complete in all respect as per specification, on 28mm thick bed of C.M. 1:4 :Light shade using shade cement. |
| 44 | Supply and fixing in cement mortar welded hand railing made out of MS round or square bars, flats etc. for staircase or verandah as per design complete in all respect (wooden or PVC hand railing to be paid extra) with priming coat of red oxide. Extrafor providing D type pipe head as top of hand railing |
| 45 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide .Extra if square,rectangular hollow tubelarsections are used or grill made by flats only |
| 46 | Providing & Fixing of Mineral Fibre Anti BacterialSuspended Ceiling System with (Bevelled Tegular) EDGETILES WITH 15 mm Exposed GRID. The tiles should haveHumidity Resistance (RH) of 95% Light Reflectance 90%, Thermal Conductivity K =0.052-0.057 w/m K, Colour White, Fire Performance UK Class 0/Class 1 (BS 476 Part 6 & 7), inmodule size of 600 x 600 x 15 mm with Anti Microbialcoating on the face of the tile, suitable for Green Building application, with Recycled content of 34 % The tile shall be laid on Silhouette profile grid system with 15 mm white/black flanges incorporating a 6 mm central reveal in white/black colour and with a web height of 45mm and a load carrying capacity of minimum 15.68 Kgs/M2 & minimum pull out strength of 100 kgs. Silhouette, Main Runners & Cross Tees to have mitred ends & \"birdsmouth\" notches to provide mitred cruciform junctions. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with suspension system of make. The Tile & Grid system used together should carry a 10 year warranty. INSTALLATION :- To comprise main runner spaced at 1200 mm centres securely fixed to the structural soffit using suspension system (Specifications below) at 1200mm maximum centre. The First/Last suspension system at the end of each main runner should not be greater than 450 mmfrom the adjacent wall. Flush fitting 1200 mm long cross tees to be interlocked between main runners at 600 mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600 mm module to be formed by fitting 600 mm long flush fitting cross tees centrally between |
| 47 | Providing and fixing in position collapsible steel shutters with vertical M.S. Channels 20 x 10 x 2mm and bracket with flat iron diagonals 20 x 5mm. size with top and bottom rail of T-iron 40 x 40 x 6mm. with 40mm dia steel pulleys/ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer. (To be measured and paid as per outer dimension). |
| 48 | Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work |
| 49 | Providing and fixing Drapery rod shall be made of 20 gauge cold rolled steel strip, which is electrical resistance welded. The section will be available 25.4 mm diameter the sectionshall be coated with acid resistance polymer finish shall madefrom ABS material in nearest matching colour of rod. The ringshall be made from ABS material in nearest matching colourto rod. Brackets made of galvanized steel. |
| 50 | Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). Polyester Powder coating aluminum( minimum thickness of powder coating 50 micron) |
| 51 | Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). For fixed portionPolyester Powder coating aluminum( minimum thickness of powder coating 50 micron) |
| 52 | Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). For fixed portionExtra for shutters of slidingaluminum windows |
| 53 | Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge. Prelaminated particle board with decorative lamination on both sides. |
| 54 | Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.) With float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm).Extra for providing frosted glass panes instead of ordinary float glass panes in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). |
| 55 | Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.) With float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm) |
| 56 | Extra for providing toughened glass panes instead of ordinary float glass panes in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).10 mm thick glass |
| 57 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. With stainless steel cover plate |
| 58 | Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 59 | Filling the gap upto 5 mm depth and 5 mm width in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. |
| 60 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia |
| 61 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 160 mm dia |
| 62 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Coupler (socket) 160 mm dia |
| 63 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Coupler (socket) 110 mm dia |
| 64 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Bend 87 .5 160 mm dia |
| 65 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Bend 87 .5110 mm dia |
| 66 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:Plain Tee110mm dia |
| 67 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:Plain Tee160 mm dia |
| 68 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:Vent Cowel 110mm dia |
| 69 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:Vent Cowel 160 mm dia |
| 70 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Pipe Clip110mm dia |
| 71 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Pipe Clip 160 mm dia |
| 72 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Plain floor trap 110mm dia |
| 73 | P & F European type white glazed vitreous china 1st quality Double syphonic W.C (IS :2556 Mark) with P or S trap including cutting and making good the wall and floor |
| 74 | P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556mark). Of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS: 1703 mark) complete including cutting and making good the wall:PVC withCP brass long band. |
| 75 | P & F WVC wash basin (1st quality, I.S. : 2556 Mark) of approved make with C.I. brackets duly painted, 1 No. 15 mm C.P. Pillar cock (IS : 8934 Mark) & 32 mm C.P. brass waste coupling of approved make, 25 mm G.I. waste pipe complete including cutting & making good the wall.: Size 450 mm x 300 mm . Size 550 mm x 400 mm dia for counter top |
| 76 | P & F Kitchen & Lab. Sink of approved make with C.I.brackets duly painted, 40 mm C.P. waste coupling, C.P. Brasschain with rubber plug, 40 mm G.I. waste pipe up-to floorlevel complete including cutting and making good the wall &floor :WVC Lab sink (IS:2556 mark) size 530 x 430 x 180 mm |
| 77 | P & F Sink Cocks of superior quality & approved made :C.P. Sink cock swinging spout 15mm. |
| 78 | Providing & Fixing premium qulaity WVC Urinal with PVCwaste pipe, dome couplings, concealed iron brackets or screwsetc. complete. Flat Back (small) size 440x265x315 mm. |
| 79 | P&F Marble Urinal Partition slab both sides polished ofapproved design cut from marble size 900x600mm.Makrana `Adanga` or Raj Nagar 1St Quality White or Andhi Indo-Italian marble. |
| 80 | P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers. Other sizes |
| 81 | P & F Acrylic Toilet accessories set consisting of Towel rail, shelf, towel ring, soap dish, paste & brush holder & twin peg of approved quality/make. |
| 82 | Providing & Fixing Premium quality Bottle trap internal portion 32mm, size 250mm long wall connection pipe & wall flangeas per approved by Engineer in Charge. |
| 83 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall)25 mm nominal outer dia pipes |
| 84 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall)20mm nominal outer dia pipes |
| 85 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge. (External work). 40 mm nominal outer dia pipes |
| 86 | P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: (-do-) Long body, 15mm nominal bore weight not less than 690 gm |
| 87 | P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : Gun-metal 25mm nominal bore. |
| 88 | P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :(-do-) 40mm nominal bore. |
| 89 | P & F water closet Seat Covers with brass hinges complete : Solid PVC (ISI marked) grade-I White for EWC. |
| 90 | P & F Grating of approved quality/make: Stainless Steel Sheet size 125mm dia. Heavy Quality of approved make |
| 91 | P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. 37 cm long Pipe and nut |
| 92 | P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. |
| 93 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it\"sISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR Short point (up to 3 mtr.) |
| 94 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it\"sISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR Medium point (up to 6 mtr.) |
| 95 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it\"sISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR Long point(up to 10 mtr..) |
| 96 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it\"s ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSROn board |
| 97 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it\"s ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSRShort point (up to 3 mtr.) |
| 98 | Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 99 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 20 mm |
| 100 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR25 mm |
| 101 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 32 mm |
| 102 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR40 mm |
| 103 | Providing & Fixing of ISO certified company made virgin material PVCtrunking system as perPWDspecificationforelectricalWorks,withdoublelock feature for cablemanagement including finishing accessories likecorners, tees, adjustableangles, junctionetc. as required . Thetrunking systemshallhave daptablesystemformodulartypeRJ45datasocket/ wiringaccessories/powersocketsandshallbecoveredwithpealoffplastic cover.OEMshall havesubmit NABLaccrediated/CPET lab test reportsbeforeexecution&All asperpreapprovedbyEngineer incharge. For additional technicalparametersofproducts/work , refer Annexure\"A\" attached with this BSR . 32mm X 20m |
| 104 | Providing & Fixing of ISO certified company made virgin material PVCtrunking system as perPWDspecificationforelectricalWorks,withdoublelock feature for cablemanagement including finishing accessories likecorners, tees, adjustableangles, junctionetc. as required . Thetrunking systemshallhave daptablesystemformodulartypeRJ45datasocket/ wiringaccessories/powersocketsandshallbecoveredwithpealoffplastic cover.OEMshall havesubmit NABLaccrediated/CPET lab test reportsbeforeexecution&All asperpreapprovedbyEngineer incharge. For additional technicalparametersofproducts/work , refer Annexure\"A\" attached with this BSR .80mm x 50mm |
| 105 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 3x 1.5 sq.mm |
| 106 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR2 x 2.5 sq. mm. + 1x1.5sqmm |
| 107 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 4 x 4.0 sq.mm |
| 108 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. |
| 109 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 4 x 6.0 sq.mm |
| 110 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. |
| 111 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR4 x 10.0 sq.mm |
| 112 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 4 x 16.0 sq.mm |
| 113 | Supplying and drawing coaxial cable 75 ohm impedance with foam PEinsulated solid bare copper inner conductor,and Istouter conductor ofbondedalum.tapeandsecondouterconductorof alum.alloybraid inexisting surface orrecessed conduit/casing capping including makingconnections as required. For additional technical parameters ofproduct / work refer Annexure \"A\" attached with this BSRRG - 6 |
| 114 | Supplying and drawing coaxial cable 75 ohm impedance with foam PEinsulated solid bare copper inner conductor,and Istouter conductor ofbondedalum.tapeandsecondouterconductorof alum.alloybraid inexisting surface orrecessed conduit/casing capping including makingconnections as required. For additional technical parameters ofproduct / work refer Annexure \"A\" attached with this BSRRG -11 |
| 115 | Supplying and drawing PE Insulated &PVCSheathed unarmouredtelephone cable with 0.5mm dia. Solid Annealedelectrolyticgrade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specificationGR /WIR/06-03March 2002 in existing surface orrecessedconduit/casingcapping.includingferrulingoneachpair for Identificationetc.asrequired.Foradditional technicalparametersofproduct / work refer Annexure \"A\" attached with this BSR 2 pair |
| 116 | Supplying and drawing PE Insulated &PVCSheathed unarmouredtelephone cable with 0.5mm dia. Solid Annealedelectrolyticgrade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specificationGR /WIR/06-03March 2002 in existing surface orrecessedconduit/casingcapping.includingferrulingoneachpair for Identificationetc.asrequired.Foradditional technicalparametersofproduct / work refer Annexure \"A\" attached with this BSR 4 pair |
| 117 | Supplying and drawing PE Insulated &PVCSheathed unarmouredtelephone cable with 0.5mm dia. Solid Annealedelectrolyticgrade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specificationGR /WIR/06-03March 2002 in existing surface orrecessedconduit/casingcapping.includingferrulingoneachpair for Identificationetc.asrequired.Foradditional technicalparametersofproduct / work refer Annexure \"A\" attached with this BSR10 pair |
| 118 | Providing & Fixing of 240/415 V AC MCB withpositive isolation of breaking capacity not lessthan 10 KA(B/C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828 (1996) /conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum, energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm.,conductorline load reversibility, label holding facility, IP 20 contact protection and fitted with existing distribution board /sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000for 80A rating including making connections , testing etc. as required. OEM shall have submit NABL / CPRI / ERDAaccrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attachedwiththis BSR . Single pole MCB 6 A to 32 A rating |
| 119 | Providing & Fixing of 240/415 V AC MCB withpositive isolation of breaking capacity not lessthan 10 KA(B/C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828 (1996) /conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum, energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm.,conductorline load reversibility, label holding facility, IP 20 contact protection and fitted with existing distribution board /sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000for 80A rating including making connections , testing etc. as required. OEM shall have submit NABL / CPRI / ERDAaccrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attachedwiththis BSR . Single pole MCB50/63 A rating |
| 120 | Providing & Fixing of 240/415 V AC MCB withpositive isolation of breaking capacity not lessthan 10 KA(B/C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828 (1996) /conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum, energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm.,conductorline load reversibility, label holding facility, IP 20 contact protection and fitted with existing distribution board /sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000for 80A rating including making connections , testing etc. as required. OEM shall have submit NABL / CPRI / ERDAaccrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attachedwiththis BSR .Double pole MCB 6 A to 32 A rating |
| 121 | Providing & Fixing of 240/415 V AC MCB withpositive isolation of breaking capacity not lessthan 10 KA(B/C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828 (1996) /conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum, energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm.,conductorline load reversibility, label holding facility, IP 20 contact protection and fitted with existing distribution board /sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000for 80A rating including making connections , testing etc. as required. OEM shall have submit NABL / CPRI / ERDAaccrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attachedwiththis BSR .Double pole MCB 50-63 A rating |
| 122 | Providing & Fixing of 240/415 V AC MCB withpositive isolation of breaking capacity not lessthan 10 KA(B/C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828 (1996) /conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum, energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm.,conductorline load reversibility, label holding facility, IP 20 contact protection and fitted with existing distribution board /sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000for 80A rating including making connections , testing etc. as required. OEM shall have submit NABL / CPRI / ERDAaccrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attachedwiththis BSR .Four pole MCB6 A to 32 A rating |
| 123 | Providing & Fixing of 240/415 V AC MCB withpositive isolation of breaking capacity not lessthan 10 KA(B/C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828 (1996) /conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum, energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm.,conductorline load reversibility, label holding facility, IP 20 contact protection and fitted with existing distribution board /sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000for 80A rating including making connections , testing etc. as required. OEM shall have submit NABL / CPRI / ERDAaccrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attachedwiththis BSR .Four pole MCB50-63 A rating |
| 124 | Providing & Fixing of 240/415 V isolator as per PWD specification for electrical Works with ISI marked IS:13947- III/conforming to IEC 60947-3, suitable for AC22A utilization catagory, 4KV impulse withstand voltage, true contact indication, Red colour dolly/ lever shall have single mould covering over all poles for operation, two position din rail mounting,minimum phase termination capacity of 35sq.mm., label holding facility , IP 20 contact protection and fitted with existing distribution board / sheetincluding making connections,testingetc.asrequired.OEMshall have submit NABL / CPRI / ERDAaccrediatedlabtest reports beforeexecution&Allasperpreapprovedby Engineer in charge. For additional technical parameters of products/work ,referAnnexure\"A\"attachedwiththis BSR . Double pole isolator 30 A / 40 A rating |
| 125 | Providing & Fixing of 240/415 V isolator as per PWD specification for electrical Works with ISI marked IS:13947- III/conforming to IEC 60947-3, suitable for AC22A utilization catagory, 4KV impulse withstand voltage, true contact indication, Red colour dolly/ lever shall have single mould covering over all poles for operation, two position din rail mounting,minimum phase termination capacity of 35sq.mm., label holding facility , IP 20 contact protection and fitted with existing distribution board / sheetincluding making connections,testingetc.asrequired.OEMshall have submit NABL / CPRI / ERDAaccrediatedlabtest reports beforeexecution&Allasperpreapprovedby Engineer in charge. For additional technical parameters of products/work ,referAnnexure\"A\"attachedwiththis BSR .Four pole Isolator63 A rating |
| 126 | Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protection as per PWD specification for electrical Works with ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA, true position indication and trip free mechanisum, line load reversibility, provision for pad lock, min. operation 10,000 upto 63 A rating and 5000 for 80 A-100 A rating, minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as perpre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .Two pole 100/300mA sensitivity 6A-32 A rating |
| 127 | Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protection as per PWD specification for electrical Works with ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA, true position indication and trip free mechanisum, line load reversibility, provision for pad lock, min. operation 10,000 upto 63 A rating and 5000 for 80 A-100 A rating, minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as perpre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . Four pole 100/300 mA sensitivity63 A rating |
| 128 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR Metal door (Three phase) IK-09 and IP-43with Metal end box6 Way |
| 129 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR Metal door (Three phase) IK-09 and IP-43with Metal end box12 Way |
| 130 | SITCof 3/4 polecurrent limitingMouldedcasecircuitbreaker(MCCB)madeof flame retardent&heat resistantmaterial having followingcurrentrating,shortcircuit breakingcapacityat440/415V,50Hz;O/L&S/Csettings,conformingtoIS/IEC60947P-2:2003withfront faceandcentralised adjustable, trip freemechanisum, true contact positionindicator, line load interchangeability, designedforbothhorizontal&verticalmountingwithoutanyadverseeffectonelectricalperformance, suitable for operationupto55degreeandwithout deratingupto40 degree, pollutiondegree3, havingpositive isolationcapability, push (test) totrip, triptime less then10msunder s/ccondition,Breakingcapacity Ics=100%Icu.Uimp=8KV, ratedinsulationvoltage 690 V.provisionforUVR,shunttrip,earthfaulttrip,doorinterlock,padlock&rotaryhandle, includingmakingconnections etc.asrequired.OEMshallhavesubmit NABL/CPRI /ERDAaccrediated labtypetestcertificatebeforeexecutionAll as per preapprovedbyEngineer incharge. Foradditional technical parametersof product /work referAnnexure \"A\" attached with this BSR4 pole MCCB With Microprocessorbasedrelease withadjustableO/L&S/C setting with Inbuilt Instantaneous and Ground fault Protection.250 Amp , 50 kA |
| 131 | SITCof 3/4 polecurrent limitingMouldedcasecircuitbreaker(MCCB)madeof flame retardent&heat resistantmaterial having followingcurrentrating,shortcircuit breakingcapacityat440/415V,50Hz;O/L&S/Csettings,conformingtoIS/IEC60947P-2:2003withfront faceandcentralised adjustable, trip freemechanisum, true contact positionindicator, line load interchangeability, designedforbothhorizontal&verticalmountingwithoutanyadverseeffectonelectricalperformance, suitable for operationupto55degreeandwithout deratingupto40 degree, pollutiondegree3, havingpositive isolationcapability, push (test) totrip, triptime less then10msunder s/ccondition,Breakingcapacity Ics=100%Icu.Uimp=8KV, ratedinsulationvoltage 690 V.provisionforUVR,shunttrip,earthfaulttrip,doorinterlock,padlock&rotaryhandle, includingmakingconnections etc.asrequired.OEMshallhavesubmit NABL/CPRI /ERDAaccrediated labtypetestcertificatebeforeexecutionAll as per preapprovedbyEngineer incharge. Foradditional technical parametersof product /work referAnnexure \"A\" attached with this BSR4 pole MCCB With Microprocessorbasedrelease withadjustableO/L&S/C setting with Inbuilt Instantaneous and Ground fault Protection.630 Amp, 50 kA |
| 132 | Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 10 A one way switch |
| 133 | Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .10 A bell push |
| 134 | Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 16 Amp. 1 Module switch With Led Indicator |
| 135 | Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .25 Amp. 1 Module switch With Led Indicator |
| 136 | P & F of occupancy sensor with a build in lighting switch designed for automatic switching on/off of lights in case of no occupancy for a pre-determined amount of time in indoor applications. The device must have a circular detection pattern for a range of 8/ 6.7 meters diameter at a mounting height of 2.7 meters. The device should be able to work with electronic ballasts and handle lighting loads upto 10A(GP1)/ 6A (GP2). |
| 137 | SITC of ISO Certified company made MNRE approved & confirming to IS:12933 P-1,2,3 & 5 Flat Plate Collector type solar hot water system with collector, insulated stainless steel (SS grade:304) storage tank with electrical back up with Portable Residual Current Device ( PRCD ) facility form OEM , CRCA Powder coated /MS stand for Collector & Tank etc. asrequired. of following capacity complete in all respect. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. Foradditional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 500 litre/ day |
| 138 | Providing & Fixing of IP 51 ( upto 500) V range Volt meter on existing panel as per PWD specification for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. Meter shall give true RMS measurments, acc. CI 1.0 or better , with field programmable primary & sec. values PT(VT) primary upto 2000 KV. Field-programmable high and low threshold values, meter shall compliance of IS 13875 & IEC 61236. as required. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab test reports before execution &All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , referAnnexure \"A\" attached with this BSR . Digital type |
| 139 | Providing & Fixing of CT operated direct reading type IP- 51 Ampere meter on existing panel as per PWD specification for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. Ampere meter shall give true RMS measurement, Acc. Cl 1.0 or better, Measuring current range 50 mA to 6 A, with Fieldprogrammable primary and secondary values CT primary up to 15000 A, Field-programmable high and low threshold values as required. compliant to IS 13875, & IEC 61326. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab test reports before execution &. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure\"A\" attached with this BSR . E080610 Digital type Confirming to IEC 62053-21 Below 500 A |
| 140 | Providing & Fixing of ISO certified company made selector switch of 10 A for voltmeter (4 position ) using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on\ copper should provided . contact assembly is of operating temp range - 25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations@300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 141 | Providing & Fixing of ISO certified company made CT linked selector switch of 10 A for Ampere meter (4 position ) using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour , including making connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 142 | Providing & Fixing of ISO certified company made UL listed , IP 65 110/220 V, unibody LED Indicating lamp IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . Red/yellow/Green colour |
| 143 | Providing & Fixing of ISO certified company made UL listed , IP 65 110/220 V, unibody LED Indicating lamp IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . Blue / white Colour |
| 144 | Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure \"A\" attached with this BSR .11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break DownVoltage 45 KV |
| 145 | Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .6 A one way switch |
| 146 | Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 6 A bell push |
| 147 | Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .16 Amp. 1 Module switch With Led Indicator |
| 148 | Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 25 Amp. 1 Module switch With Led Indicator |
| 149 | Providing & Fixing of modular type lockable feature socket duly ISI marked (IS :1293) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .6 A 3 pin shuttered socket |
| 150 | Providing & Fixing of modular type lockable feature socket duly ISI marked (IS :1293) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .16 A 6 pin shuttered socket |
| 151 | Providing & Fixing of modular type lockable feature socket duly ISI marked (IS :1293) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .25 Amp. 2 Module Socket |
| 152 | Providing & Fixing of modular type Step Fan regulator duly ISI marked (IS :11037) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .5 step fan regulator 100 watt 1 Module |
| 153 | Providing & Fixing of following modular accessories as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .RJ-11 telephone jack single two line |
| 154 | Providing & Fixing of following modular accessories as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . USB Charger 1 A - 1 M with BIS mark |
| 155 | Providing & Fixing of following modular accessories as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . RJ-45 computer jack with shutter |
| 156 | Providing & Fixing of following modular accessories as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .T.V. coaxial socket |
| 157 | Providing & Fixing of following modular accessories as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .Blanking plate |
| 158 | Providing & Fixing of following modular accessories as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .Modular MCB 6 A to 32 A DP (IS:8832 marked) |
| 159 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcableconfirmingtoIS:1554P-I / IS:7098P- Iof1.1KVwith H4 GradeelectrolyticaluminiumconductorconfirmingtoIS8130ofpurity>99.6%, round/flatstriparmouringofcables, Inner/outersheathconfirmingtoIS:5831 inexistingRCC/Hume/Stoneware/PVCpipe/openduct/cabletrench/Cable tray(withcabletie)including testingetc.asrequiredoffollowingsize.OEMmust haveit\"sowninhouseNABLaccrediatedLaboratoryfortestingprocedureasper IS:10810.Foradditional technicalparametersofproduct/workreferAnnexure \"A\" attached with this BSR95.0 Sq. mm 3.5 core |
| 160 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcableconfirmingtoIS:1554P-I / IS:7098P- Iof1.1KVwith H4 GradeelectrolyticaluminiumconductorconfirmingtoIS8130ofpurity>99.6%, round/flatstriparmouringofcables, Inner/outersheathconfirmingtoIS:5831 inexistingRCC/Hume/Stoneware/PVCpipe/openduct/cabletrench/Cable tray(withcabletie)including testingetc.asrequiredoffollowingsize.OEMmust haveit\"sowninhouseNABLaccrediatedLaboratoryfortestingprocedureasper IS:10810.Foradditional technicalparametersofproduct/workreferAnnexure \"A\" attached with this BSR 185.0 Sq. mm3.5 core |
| 161 | Pipe Earthing as per PWD specification for electrical Works as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. \" B \" class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 162 | Mesh earthing as per IS:3043 with GI earth strip of size 25 mm x 6 mm to form a mesh of size 3000 mm x 1000 mm in horizontal formation to create equal sections of 500 mm x 500 mm by means of 10 mm brass bolts, & nuts with spring washer, embodying 1 mtr. below the ground level, refilling the pit by alternative layers of charcoal & salt up to 500 mmwith 20 mm dia. GI \"B\" class watering pipe, wire mesh funnel and brick masonary finished chamber covered with hinged MS cover of 6 mm thickness and locking arrangement of size 300 mm x 300 mm complete in all respect including connections and testing as required. Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 163 | P & F 18 swg M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 164 | Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic bladeceiling fan as per PWD specification for electrical Works, conforming to IS:374-2019, & IS:1885 -P-V1981. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) |
| 165 | Providing & Fixing of heavy duty, copper wound , Double ball bearing and with metal sturdy mesh guard; Aluminium alloy one piece blade wall mounting oscillating type air circulator as per PWD specification for electrical Works, conforming to IS:2997, includingfixing with anchor bolts, regulator making connection testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .450 mm sweep With wall Mounting and three speed regulator |
| 166 | Providing & Fixing of Heavy duty capacitor start, copper woind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 450 mm sweep(900/1400 RPM) |
| 167 | Providing & Fixing of of ventilating fans Capacitor start, copper wounded, single phase with PVC impeller, ABS body, automatic openable louver shutter in existing opening including making connection, testing etc. as required. OEM shall be an ISO certified company.Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 250 mm sweep |
| 168 | Providing & Fixing of energy efficient / energy saving direct fit (Retrofit) composite self ballasted compact fluorscent lamp (CFL) with PF >0.85 in existing holder / fixture as required complete in all respect. All as per pre approved by Engineer in charge. Foradditional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 8/9 Watt |
| 169 | Providing & Fixing of IP40 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing & Heat Sink for heat dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy of ≥ 120 lm / watt, THD <10 % ,p.f.≥0.95, CRI >80, life time of minimum 50000 BurningHours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure \"A\" attacheded with this BSR.Recessed MountingLED Downlight 6/7W |
| 170 | Providing & Fixing of IP40 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing & Heat Sink for heat dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy of ≥ 120 lm / watt, THD <10 % ,p.f.≥0.95, CRI >80, life time of minimum 50000 BurningHours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure \"A\" attacheded with this BSR.Recessed Mounting LED Downlight 18/20W |
| 171 | Providing & Fixing of IP40 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing & Heat Sink for heat dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy of ≥ 120 lm / watt, THD <10 % ,p.f.≥0.95, CRI >80, life time of minimum 50000 BurningHours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure \"A\" attacheded with this BSR.Recessed Mounting LED Downlight 18/20W |
| 172 | Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection and in compliance to IEC standards (Integral with lightfixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure \"A\" attacheded with this BSR. Recessed mounting 36W LED Light 2’x2’ with acrylic/ prismatic front cover |
| 173 | Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from polycarbonate /extruded aluminium powder coated housing with in built driver , Power Consumption of 18W/20W ,system lumen efficacy ≥ 120 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% ,p.f.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure \"A\" attacheded with this BSR. 4\" LED Tube shape fixture 18/20 W (Polycarbonate Base) |
| 174 | Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray (Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work ,refer Annexure \"A\" attached with this BSR . 300mm x 50mm x 1.6mm |
| 175 | UPS, Capacity 5 KVA, 230 VAC, 50 Hz. with 1 hr battery backup forall the Analysers only |
| 176 | (ITEM TAKEN FROM PWD BSR 2019 CHAPTER 30,) Supplying , installation , Testing and commissioning of the passenger / goods / Stretcher or Bed elevator having following main features:(a)MOTOR : Gearlesslift drivecomprising of high starting torque lift duty , 3 phase 440 Volts A.C. permanent magnetic synchronous motor of proper rating with high efficiency shall be used. (b) Operation / Drive : Microcessor based /PLC, AC Variable Voltagevariable frequency variable speed (V3F) vector control drive with encoder feedback closed loop system shall be used for lift car and door operationwhich shall be full collective selective operation hall call demand response , UP/Down hall stops , main , Up/Down contactor with overload and phase reversal relay and safety controls . ( c ) Traction Media: main hoist flat coated steel belt / rope . Thimbles of spring permit adjustment of uniform tension for smooth operation of the elevator Pulse belt monitoring system to avoid the cut in the belt.(d) Car :car should be with M S platform with bracings of adquate size and to sustain the impact load cabin plus passengers with safety factor of fire for steel withAnti skid PVC flooring and side panels should be of Stainless steel with hair line finish of sheet of grade 304 duty with S.S. handrails . Car ceiling shall be steel finish with aesthetic appearances with LED ceiling lights .The size of the car shall be taken as per available lift well size and relevant BIS code of lifts . Car panel will also be ofS S 304 gradefinished with emergency stop device , emergency alarm,mechanical door safety device ,full length infra-red curtain in car door , facility of auto/attended mode . All car panel buttons and all floor switches must be with brail language as per lift act. Agency shall also provide & install one No. 2 MP , IR , IP based ceiling mounted Dome Camerain the car complete with connecting cables & accessories (To be connected with existing CCTV system in the Building) .The inspection unit shall be provided at the top of the car.(e)Landing Doors : All landing door shall be fully automatic centre opening / telescopic made of hair line finish stainless steel grade 304 with key holes and infrared curtains with unlocking facility from outside.(f) Emergency light: Appropriate rechargeable battery operated LED emergency light in the car and along with alarm switch shall be provided.(g) ARD: Automatic rescue Device (ARD) shall be provided according to passenger capacity with SMF batteries of approved brands as per BSR.(h) Audio-Visual Indication : Audio visual indication in the lift car, showing over loadingsuch that doors kept open till excess load is removed. (i) Scrolling Indicators: Digital scrolling indicator system for up-down arrow with floor position indicator shall be provided inside the car and at all stops/floors.(j) Buffers : Spring buffers/PU Buffers shall be provided.(k) Car Fan :ENERGY EFFICIENT Car fan/blower with automatic sleep timer shall be provided.(l) Voice Annunciator: Voice annunciator with suitable music shall be provided in lift car.(m) Self diagnostics system for operational and safety parameters shall be provided in control panel .(n) Mechanical/Electronic over speed governor , door key holes in the floor doors, fireman switchshall be provided .(o) Lift machine hoisting arrangement in the lift machine room , counter balance to promote smooth and economic operation complete with steel guide rails for the car & counter weight ,Trap Door , Lifting hooks as requiredand monkey ladders for lift pit should be provided by theagency along withall other steel structure works , foundations for the machine etc as required.(p) Permanent wiring in lift machine roomand in lift well with providing and fixing of electrical distiribution boardcomplete with SP & TP MCB\"s , proper numbers of light points, with LED fixtures , exhaust fan , 2 nos copperplate /chemical earthing with 8 SWG copper earth wire and plug points shall be provided by the agency . ( Power supply of 3 phase 440 V shall be made available by department in lift machine room .)(q) All civil work related to installation of lift like finishing , cleaning and levellingof lift pit , white wash of lift welland in machine room shall be done by the lift erecting agency without any extra cost. (r) Granite or marble claddingaround all landing door openings shall be in the scope of lift installation agency and additional payment shall be made according to the actual measurement / schedule by the department to thelift agency.( s) Agency has to provide all working drawings and documents to comply latest BIS specifications and make proper liasion services for obtaining all necessary permissions. 13 passengers/884 Kg, 3 stops , rated speed adjustable up to 1.0 mtr /sec with 2 years comprehensive maintenance / DLP . |
| 177 | (ITEM TAKEN FROM PWD BSR 2019 CHAPTER 30,) Supplying , installation , Testing and commissioning of the passenger / goods / Stretcher or Bed elevator having following main features:(a)MOTOR : Gearlesslift drivecomprising of high starting torque lift duty , 3 phase 440 Volts A.C. permanent magnetic synchronous motor of proper rating with high efficiency shall be used. (b) Operation / Drive : Microcessor based /PLC, AC Variable Voltagevariable frequency variable speed (V3F) vector control drive with encoder feedback closed loop system shall be used for lift car and door operationwhich shall be full collective selective operation hall call demand response , UP/Down hall stops , main , Up/Down contactor with overload and phase reversal relay and safety controls . ( c ) Traction Media: main hoist flat coated steel belt / rope . Thimbles of spring permit adjustment of uniform tension for smooth operation of the elevator Pulse belt monitoring system to avoid the cut in the belt.(d) Car :car should be with M S platform with bracings of adquate size and to sustain the impact load cabin plus passengers with safety factor of fire for steel withAnti skid PVC flooring and side panels should be of Stainless steel with hair line finish of sheet of grade 304 duty with S.S. handrails . Car ceiling shall be steel finish with aesthetic appearances with LED ceiling lights .The size of the car shall be taken as per available lift well size and relevant BIS code of lifts . Car panel will also be ofS S 304 gradefinished with emergency stop device , emergency alarm,mechanical door safety device ,full length infra-red curtain in car door , facility of auto/attended mode . All car panel buttons and all floor switches must be with brail language as per lift act. Agency shall also provide & install one No. 2 MP , IR , IP based ceiling mounted Dome Camerain the car complete with connecting cables & accessories (To be connected with existing CCTV system in the Building) .The inspection unit shall be provided at the top of the car.(e)Landing Doors : All landing door shall be fully automatic centre opening / telescopic made of hair line finish stainless steel grade 304 with key holes and infrared curtains with unlocking facility from outside.(f) Emergency light: Appropriate rechargeable battery operated LED emergency light in the car and along with alarm switch shall be provided.(g) ARD: Automatic rescue Device (ARD) shall be provided according to passenger capacity with SMF batteries of approved brands as per BSR.(h) Audio-Visual Indication : Audio visual indication in the lift car, showing over loadingsuch that doors kept open till excess load is removed. (i) Scrolling Indicators: Digital scrolling indicator system for up-down arrow with floor position indicator shall be provided inside the car and at all stops/floors.(j) Buffers : Spring buffers/PU Buffers shall be provided.(k) Car Fan :ENERGY EFFICIENT Car fan/blower with automatic sleep timer shall be provided.(l) Voice Annunciator: Voice annunciator with suitable music shall be provided in lift car.(m) Self diagnostics system for operational and safety parameters shall be provided in control panel .(n) Mechanical/Electronic over speed governor , door key holes in the floor doors, fireman switchshall be provided .(o) Lift machine hoisting arrangement in the lift machine room , counter balance to promote smooth and economic operation complete with steel guide rails for the car & counter weight ,Trap Door , Lifting hooks as requiredand monkey ladders for lift pit should be provided by theagency along withall other steel structure works , foundations for the machine etc as required.(p) Permanent wiring in lift machine roomand in lift well with providing and fixing of electrical distiribution boardcomplete with SP & TP MCB\"s , proper numbers of light points, with LED fixtures , exhaust fan , 2 nos copperplate /chemical earthing with 8 SWG copper earth wire and plug points shall be provided by the agency . ( Power supply of 3 phase 440 V shall be made available by department in lift machine room .)(q) All civil work related to installation of lift like finishing , cleaning and levellingof lift pit , white wash of lift welland in machine room shall be done by the lift erecting agency without any extra cost. (r) Granite or marble claddingaround all landing door openings shall be in the scope of lift installation agency and additional payment shall be made according to the actual measurement / schedule by the department to thelift agency.( s) Agency has to provide all working drawings and documents to comply latest BIS specifications and make proper liasion services for obtaining all necessary permissions.Note: Add Rs 65,000/- per stop in the above rate for elevator up to 13 passenger and10 stops (For Item no.E305201 to E305204) . |
| 178 | Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 179 | Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture , material should be PC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure \"A\" attached with this BSR . Single Aperture |
| 180 | Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors as per ANSI/TIA/EIA 568 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568, minimum requirement for 1G BASE-T/ 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, Minimum 750 to 1000 mating cycles in plug contacts for long durability complete in all respect. All as per pre approved by Engineer in charge. For additional technical parametersof products/ work , refer Annexure \"A\" attached with this BSR.E200610 Cat 6, UTP (Un-sheilded Twisted Pair) Patch Cord1 Mtr |
| 181 | Supply, Drawing and Testing, of stranded Multi mode (50/125 µm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC 11801:2011/ IEC 60794-1- 2 E1, E3,E11, F1/ EN 50173-1/ EN 187 000/ IEC 60974-2, 2-20, 2-21/ ITU G.652D, construction of LSZH outer sheath cable, cable should be used for LAN and WAN back bones, . With its LSZH sheathing these cables should be ideal for indoor/outdoor installations in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .6 fiber |
| 182 | E200300 Supply and Installation of unsheilded/ sheilded Information outlets made of high impact plastic body with ABS, FR Grade with provision for protection against dust in jack/ FP, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact punch termination on reliable copper tin plated Insulation displacement contact, It complied with ANSI/TIA/EIA 568 standard. In existing modular/MS Boxes along with necessory connections as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR. Cat 6, Un-sheilded Information Outlet |
| 183 | Supply, Installation, Testing and Commissioning of Wall mounted ISO 9001:2015 & 14001 or higher level certified company made Communication enclosure (Rack) of Minimum 500 MM Depth with made from CRCA & hot dip powder coated, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with \"U\"Marking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19\" angles with wall mounting provision on wall. Accessories like: 1 No of 19\" 1U Horizontal Cable manager, 2 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19\" 1U, mountable socket strips with 6 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with fastner of suitable capcity etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .9 U wall mounted Enclosure |
| 184 | Supply , Installation, Testing and Comissioning of Unmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 10/100/1000 MBPS gigabit auto-negotiation RJ45 ports, IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 24 Port |
| 185 | Supply, installation, Testing and Commissioning of 1000 base-LX/LH single mode/Multi mode fibre to 1000 base-T copper giga bit , Media Convertor complete as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 186 | Fiber Fusion Splicing with OTDR Testing of Fiber Single/ Multi mode (per splice) of glass Fiber Optic Cable including cleaning the cable and making splice as per standard practice complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure\"A\" attached with this BSR . |
| 187 | SITC of MGPS of medically grade as per BSEN-13348 with third party certification from Lloyds/TUV degreased [ie free from oil, grease and particulate matters) seamless copper pipe confirming to ASTM BBB and all copper joining done by brazing with AWSAS.B, classification BCuP-S or BS 1845 following procedure in accordance with ASTM BB2B after purging with nitrogen. All pipe cutting shall be carried out with a radial pipe cutter and copper pipe fitting\"s shall comply with 84 alloy designation. Adequate support shall be provided while laying pipeline testing shall be done at L7 bar and after testing pipe shall be painted with two coat of enamel paint as per colour codification as per ISO 7396-Part-\2076. |
| 188 | SITC of non lubricated ball type GM Isolation Valve with adapter & PTFE Seat having quarter turn handle opening of following sizes suitable for flow capacity 1500 LPM at 4.7 bar with maximum allowable pressure of 30 bar and suitable for working temperature ranging - 20\"C to L30\"C.Valve should beCE approved/ CE certified. Annexure \"A\" attached with this BSR .For 12 MM OD pipe |
| 189 | SITC of non lubricated ball type GM Isolation Valve with adapter & PTFE Seat having quarter turn handle opening of following sizes suitable for flow capacity 1500 LPM at 4.7 bar with maximum allowable pressure of 30 bar and suitable for working temperature ranging - 20\"C to L30\"C.Valve should beCE approved/ CE certified. Annexure \"A\" attached with this BSR .For 15 MM OD pipe |
| 190 | SITC of non lubricated ball type GM Isolation Valve with adapter & PTFE Seat having quarter turn handle opening of following sizes suitable for flow capacity 1500 LPM at 4.7 bar with maximum allowable pressure of 30 bar and suitable for working temperature ranging - 20\"C to L30\"C.Valve should beCE approved/ CE certified. Annexure \"A\" attached with this BSR .For 22 MM OD pipe |
| 191 | SITC of non lubricated ball type GM Isolation Valve with adapter & PTFE Seat having quarter turn handle opening of following sizes suitable for flow capacity 1500 LPM at 4.7 bar with maximum allowable pressure of 30 bar and suitable for working temperature ranging - 20\"C to L30\"C.Valve should beCE approved/ CE certified. Annexure \"A\" attached with this BSR .For 28 MM OD pipe |
| 192 | SITC of non lubricated ball type GM Isolation Valve with adapter & PTFE Seat having quarter turn handle opening of following sizes suitable for flow capacity 1500 LPM at 4.7 bar with maximum allowable pressure of 30 bar and suitable for working temperature ranging - 20\"C to L30\"C.Valve should beCE approved/ CE certified. Annexure \"A\" attached with this BSR . For 42 MM OD pipe |
| 193 | SITC of non lubricated ball type GM Isolation Valve with adapter & PTFE Seat having quarter turn handle opening of following sizes suitable for flow capacity 1500 LPM at 4.7 bar with maximum allowable pressure of 30 bar and suitable for working temperature ranging - 20\"C to L30\"C.Valve should beCE approved/ CE certified. Annexure \"A\" attached with this BSR . For 54 MM OD pipe |
| 194 | SITC of Gas outlet point (AR -4), (AR - 7) and vaccum (8.7 Psig) for disPensing medical gases [oxygen/air/VaccumJ at point of use confirming to BSEN ISO 9170-1:2008. The gas outlet are quick connect type. it should have colour coding for dieffrentgas source and should accept only respective adapters as required. |
| 195 | SITC of suction unit (suction Controller and Collection |ar) with posibility to conftgure required capacity capacity collection jar and should meets the requirements as per BSEN IS0 10079-3:2009. The unit must designed to operate with the vaccum line of MGPS. the cotlection jar must accumpained with Vaccum regulator suitable for 0-14.7 psig with flow rate 0-55 Lmp (min) for opeiating temperature -. 18\"C. to 20c with ON/OFF facility. the collection jar should be transparent, made of high quality polycarbonate that can be autoclaved at 121 degree for 20 minutes for reuse and provided with auto stop to avoid over spill and contamination of the suction source when the jar collection reached optimized level. the complete unit supplied with filter to protect the source and pipe line from bacterial contamination.1000 ml Capacity collection jar |
| 196 | SITC of Valve box made of CRCA sheet duly powder coated with transparent window which is installed in the MGPS for oxygen and vaccum line and should comply with ENISOS211.2001 complete with ball type valves and gauses as required for oxygencompressed air and vaccum line fthree gas) For Three gas |
| 197 | SITC of Valve box made of CRCA sheet duly powder coated with transparent window which is installed in the MGPS for oxygen and vaccum line and should comply with ENISOS211.2001 complete with ball type valves and gauses as required for oxygencompressed air and vaccum line fthree gas) For Four gas |
| 198 | SITC of microprocessor based auto alarm system (digital type) suitable for medical gas service provided with audible and visual alarm for MGPS Zoning. It should monitors the current status of oxygen /compressed air pressure in distribution pipeline of central medical supply system and trigger the alarm to alert. The system should comply BSEN IS0: 73 96- 1 :2007 For Three Gas Services |
| 199 | SITC of microprocessor based auto alarm system (digital type) suitable for medical gas service provided with audible and visual alarm for MGPS Zoning. It should monitors the current status of oxygen /compressed air pressure in distribution pipeline of central medical supply system and trigger the alarm to alert. The system should comply BSEN IS0: 73 96- 1 :2007 For Four Gas Services |
| 200 | SITC of HP Stainless Steel Tube for Oxygen/Vacuum work should beexecuted as per direction of Engineer in charge of CE Certified make. |
| 201 | SITC of Bed Head Panel of 1200 -1500 MM long made out from high strength extruded aluminium with powder coating with 4 nos 6/L6 Amp switch socket and provision forfour Nos gas outlet point work should be executed as per directions of engineer in charge and of CE certified makes. |
| 202 | Providing and fixing of Rail clamp for mountin ward vaccum unit on bed head panel com Plete as required\" |
| 203 | SITC of High pressure Rubber Tube for Oxygen/Vacuum work should be executed as per direction of Engineer incharse of CE Certified. |
| 204 | P8.F of B.a Panel accessories like Monitor Tray, Utility Basket, VacuumSlider, Infusion PumP Pole with IV hooks, with proper nut bolts and screw and with Proper finishing & work should be executed as per directions of engineer in charge of CE certified/ CE Approved.Utility Basket |
| 205 | P8.F of B.a Panel accessories like Monitor Tray, Utility Basket, VacuumSlider, Infusion PumP Pole with IV hooks, with proper nut bolts and screw and with Proper finishing & work should be executed as per directions of engineer in charge of CE certified/ CE Approved. Vacuum Slider |
| 206 | P8.F of B.a Panel accessories like Monitor Tray, Utility Basket, VacuumSlider, Infusion PumP Pole with IV hooks, with proper nut bolts and screw and with Proper finishing & work should be executed as per directions of engineer in charge of CE certified/ CE Approved.Infusion PumP Pole |
| 207 | SITC of Automatic Gas Control Panel for Each oxygen/Nitrous 0xide - Control Panel .out made for M.S. duly Powder coated. Compact and fully automatic manifold control system for 0xygen services. Easy to maintain and use. Designed with both safety and continuity of flow supply at a constant pressure via two banks of bottled gas cylinders with following status monitoring. A -Bank in use [Green Indicationi f - EmPW bank [Red Indication). Control Panel should have built in LED display to indicate Normal, High & Low line pressure. It.should have facility to test all above indicators working perfectly. the control panel should include pressure gauge to indicate the gas pressure of each header and pipe line distribution pressure. Capable to provide a distribution flow rate in excess of 1200 LPM. The control panel should incbrporate manual bypass system in case of failure of shifting mechanism. It should be of CE certified product. |
| 208 | SITC of Oxygen/ Nitrous Oxide Manifold System (1,2+12) with tail pipes NRV - manifold system comprise of bank of 1,2+12 cylinders (Bulk cylinder of D type) capacity manifold high pressure copper pipe of size 1/2 \" x14 swg (approx. 2.0320 mm) & high pressure fitting made of high tensile strength brass be used to connect the cylinders to the header assemblies with 24 no,s non return valves & 24 no\"s high pressure flexible tail pipe is made of copper pipe of 1f3\"x1-6 swg (approx. L.6256 mm) the manifold is hydraulically tested at 225kg/cm2 pressure it is also degreased and is to be offered duly wrapped in a polythene bag make CE Approved/CE certified Note : Providing of Cylinders is in the scope of Hospital / End Client. |
| 209 | SITC of Oxygen/Nitrous Oxide Manifold System [B+B) with tail pipes NRV - manifold system comprise of bank of 8+8 cylinders (Bulk cylinder of D type) capacity manifold high pressure copperpipe of size 1/2 \" x14 swg (approx. 2.0320 mm) & high pressure fitting made of high tensile strength brass be used to connect the cylinders to the header assemblies with 24 no,s non return valves & 24 no\"s high pressure flexible tail pipe is made of copper pipe of 1f3\"x1-6 swg (approx. L.6256 mm) the manifold is hydraulically tested at 225kg/cm2 pressure it is also degreased and is to be offered duly wrapped in a polythene bag make CE Approved/CE certified Note : Providing of Cylinders is in the scope of Hospital / End Client. |
| 210 | SITC of Dessicant Air Dryer 0utput Capacity - 60 cfm with UL CertifiedMicroprocessor Controller with dewpoint based changeover option,Pre-filter rating 0.3 microns , Shuttle valve for Low Pressure drop, AIIAluminium resist oxidation & scale formation, Dewpoint better than -40 degree C including fixing on wall with required T & P making connections etc complete in all respect. |
| 211 | SITC of Compressed Air System should consist of 1 nos. Air Compressors with Electric Motors, Electrical Switch Gear and Automatic Control SYstem of following Specifications:a)- Air Compressor L(0ne) Nos; Type Non-lubricated / Oil-free; Capacity 57 cfm at 8.5 kg/cm2; Cooling Air cooled b) Drive- Electric Motor 2 [two) Nos; Capacity 15 HP; Speed L440 rpm (syn.); Drive Belt drive; Electricity supply 440 volt, 50 Hz. 3 Phasec) Starter Star/Delta Control & Switchgear with overload protection.including making PCC foundation and fixing withbolts , anti vibration pad and making connections complete as required. |
| 212 | SITC of Vacuum Pump of Single stage, capacity 4235 lpm / L49cfm(Piston displacementJ. The pumP should be suited for maximum working pressure of 29 inch mercury [730 mm mercury) The pump should be fitted with MS channel frame comPlete having vibration isolators with 1 Nos.silencers at vacuum pump discharge end. The pump should be air cooled.l sets of isolation valve, on return valve and filter should be provided with pumps. Drive Assembly. The electrical drive for vacuum pump should consist of suitable TEFC induction motor operating at 1440 RPM and connected through a V-belt. The motor shouldbe suited for 415v + 10% 50 HZ .3 Phase AC supply. Capacity : 10 HP of a rePuted make Vacuum Switch Vacuum switch of 0-760 mm range should be provided, it should have both NO/NC contracts and suitable for 230 V 50 Hz.AC supply. The vacuum switch I should be housed in weather Prool I casing with 3/B\"BSP gas service I connection at the bottom of the Assembly. vaccum filter 1 Nos vacuum filters with drain valve. This filter should be non-ferrous and in line. including making PCC foundation and fixing with bolts , anti vibration pad and making connections complete as reouired. |
| 213 | SITCof Compressed air filtration system:One set of 3 - stage filter The filters should be made of die cast aluminums housing with epoxy power paint on the outside and anodized surface treatment inside to prevent corrosion and ensure extra long life. The filters should have maximum contaminant removal efficiency with minimum pressure drop. Total 3-stage of filters should be used as mentioned below:-Stage 1 : coalescing filters for generalpurpose protection, removing liquid water and oil aerosol to 0.1 mg/cum. [0.1 pm) and particles down to 5 micron.Stage 2 : particular filter for dust protection, removing particles down to 1 micron. Stage 3 : high efficiency coalescing filters, removing liquid water and oilaerosol to 0.01 mg/cu.m. (0.01 pip) and particles down to 0.0L micron. |
| 214 | Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class pipes conforming to IS 3589 / 1239 part-I for hydrent and sprinkler applications including cutting, screwing, welding etc & malleable iron fittings like elbows, tees, flanges, tapers, reducer, with compressed asbestos gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts as per approved spacing. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of Post office red shade complete as required.Complete installtion shall be pressure tested at 14kg/sqcm for 24 hr as per practice complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 25 mm dia |
| 215 | Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class pipes conforming to IS 3589 / 1239 part-I for hydrent and sprinkler applications including cutting, screwing, welding etc & malleable iron fittings like elbows, tees, flanges, tapers, reducer, with compressed asbestos gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts as per approved spacing. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of Post office red shade complete as required.Complete installtion shall be pressure tested at 14kg/sqcm for 24 hr as per practice complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .32 mm dia |
| 216 | Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class pipes conforming to IS 3589 / 1239 part-I for hydrent and sprinkler applications including cutting, screwing, welding etc & malleable iron fittings like elbows, tees, flanges, tapers, reducer, with compressed asbestos gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts as per approved spacing. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of Post office red shade complete as required.Complete installtion shall be pressure tested at 14kg/sqcm for 24 hr as per practice complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 40 mm dia |
| 217 | Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class pipes conforming to IS 3589 / 1239 part-I for hydrent and sprinkler applications including cutting, screwing, welding etc & malleable iron fittings like elbows, tees, flanges, tapers, reducer, with compressed asbestos gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts as per approved spacing. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of Post office red shade complete as required.Complete installtion shall be pressure tested at 14kg/sqcm for 24 hr as per practice complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 50 mm dia |
| 218 | Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class pipes conforming to IS 3589 / 1239 part-I for hydrent and sprinkler applications including cutting, screwing, welding etc & malleable iron fittings like elbows, tees, flanges, tapers, reducer, with compressed asbestos gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts as per approved spacing. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of Post office red shade complete as required.Complete installtion shall be pressure tested at 14kg/sqcm for 24 hr as per practice complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 65 mm dia |
| 219 | Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class pipes conforming to IS 3589 / 1239 part-I for hydrent and sprinkler applications including cutting, screwing, welding etc & malleable iron fittings like elbows, tees, flanges, tapers, reducer, with compressed asbestos gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts as per approved spacing. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of Post office red shade complete as required.Complete installtion shall be pressure tested at 14kg/sqcm for 24 hr as per practice complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .80 mm dia |
| 220 | Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class pipes conforming to IS 3589 / 1239 part-I for hydrent and sprinkler applications including cutting, screwing, welding etc & malleable iron fittings like elbows, tees, flanges, tapers, reducer, with compressed asbestos gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts as per approved spacing. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of Post office red shade complete as required.Complete installtion shall be pressure tested at 14kg/sqcm for 24 hr as per practice complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .100 mm dia |
| 221 | Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class pipes conforming to IS 3589 / 1239 part-I for hydrent and sprinkler applications including cutting, screwing, welding etc & malleable iron fittings like elbows, tees, flanges, tapers, reducer, with compressed asbestos gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts as per approved spacing. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of Post office red shade complete as required.Complete installtion shall be pressure tested at 14kg/sqcm for 24 hr as per practice complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .150 mm dia |
| 222 | Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class pipes conforming to IS 3589 / 1239 part-I for hydrent and sprinkler applications including cutting, screwing, welding etc & malleable iron fittings like elbows, tees, flanges, tapers, reducer, with compressed asbestos gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts as per approved spacing. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of Post office red shade complete as required.Complete installtion shall be pressure tested at 14kg/sqcm for 24 hr as per practice complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .200 mm dia, 6.0 mm thick |
| 223 | Supplying, Installation, Testing & Commissioning of pressure switches for Main, Jockey, Terrace pump and standby Diesel pumps, including necessary control wiring From pressure switch upto control panel and Ball valve complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 224 | Providing & fixing vane type water flow switches with contacts for installation in 50 mm to 150 mm dia M.S. pipe for a service pressure up to 20 Kg / Sq.cm complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . Each 4712.0 |
| 225 | Providing & fixing pressure transducer in M.S. Pipe line (pressure range 3.5 kg/cm2) suitable for 12 volts/24 volt DC. Including connection etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 226 | Supplying, Installation, Testing & Commissioning of floor mounted dust and vermin proof compartmentalised cubical type main fire pump control panel made out of CRCA sheet , required hardware ,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate M.S. base channel ,hinged door with locking arrangement for equipment/switchgear . Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of anycompartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors and having accessories/ switch gear (as per Specf Ch-06 & 08) as below:- complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .Incomer 400 Amp. TPN MCCB (adj.O/L) with Extended ROM, 36 kA, with Thermal magnetic release, Analouge Ammeter, Voltmeter, Selector switches,CT,Indicating Lamps, 500 Amps FP Alum. Bus bar with with heat shrinkable sleeves. Out going(a) 200 Amp. TPN MCCB(adj.O/L) with Extended ROM, 36 kA, with Thermal magnetic release, Analouge Ammeter, Voltmeter, Selector switches,CT, Indicating Lamps for \"ON\", \"OFF\", \"TRIP\" 1 no. DOL Starter of rating upto 75 HP with thermal over load relay, timer, push buttons, Auto / Manual selector switch, Single phase preventor - 2 Sets(b) 63 Amp. TPN MCCB (adj.O/L) with Extended ROM, 16 kA, with Thermal magnetic release, Digital Ammeter, Voltmeter, Selector switches, CT, Indicating Lamps for \"ON\", \"OFF\", \"TRIP\" 1 no. DOL Starter of 5 - 15 HP with thermal over load relay, timer, push buttons, Auto / Manual selector switch, Single phase preventor - 1 Set(c) One no. Diesel Engine Auto Starting kit with Auto Manual selector switch & 3 attempt starting device, timers, relays, Indicating lamp for High / Low Lub. Oil pressure, High water temperature and engine ONindication, DC ammeter & voltmeter(d) System controller to control Operation Main Electric pumps, Diesel pump, jockey pump in sequence consisting of relays, timers, sensors, annuciation window for fault indication.(e) Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturer shall be submitted. |
| 227 | Supplying and fixing cylindrical air vessel of continuous welded construction for pump room made of 450 mm dia,fabricated out of 10 mm thick dished ends and 8 mm thick MS sheet, 2000 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia drain valve,air release valve,safety valve pressure gauge with required accessories and painting with two coats of Red Oxide and two coat of post office red enamel paint as required complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 228 | Supplying and Fixing of Y type strainer fabricated out of cast iron/ steel body, strainer shall have 1.6 mm. thick stainless steel sheet perforated screen with 3 mm. dia holes with flange at both ends complete with nuts, bolts, washers, gaskets etc of following sizes. complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .200 mm dia |
| 229 | Supplying and fixing, testing & commissioning of double flanged sluicevalve conforming to IS 780 -1984 of rating PN 16 with non risingspindle, bronze /gun metal seat ISI marked complete with nuts, bolts,washers, gaskets,flanges of following sizes as required. complete in all respect.Appropriate Test Certificate/ report of product/accessoriesfrom OEM shall be submitted. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work , referAnnexure \"A\" attached with this BSR . 200 mm dia |
| 230 | Supply, installation, testing and commissioning of dual plate non-return valve (PN-16) of following sizes confirming to IS:5312 -1975 complete with flanges,rubber gasket, nut,bolts, washers etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 100 mm dia |
| 231 | Supply, installation, testing and commissioning of dual plate non-return valve (PN-16) of following sizes confirming to IS:5312 -1975 complete with flanges,rubber gasket, nut,bolts, washers etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .200 mm dia |
| 232 | Providing, installation, testing and commissioning of Brass ball valves (PN-16) duly ISI marked confirming to IS : 9890-1981 complete with flanges,Nuts, Bolts, washers, gaskets etc of following sizes as required complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .25 mm dia. |
| 233 | Providing, installation, testing and commissioning of Brass ball valves (PN-16) duly ISI marked confirming to IS : 9890-1981 complete with flanges,Nuts, Bolts, washers, gaskets etc of following sizes as required complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .32 mm dia |
| 234 | Providing, installation, testing and commissioning of Brass ball valves (PN-16) duly ISI marked confirming to IS : 9890-1981 complete with flanges,Nuts, Bolts, washers, gaskets etc of following sizes as required complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .40 mm dia |
| 235 | Providing, installation, testing and commissioning of Brass ball valves (PN-16) duly ISI marked confirming to IS : 9890-1981 complete with flanges,Nuts, Bolts, washers, gaskets etc of following sizes as required complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .50 mm dia |
| 236 | Providing & fixing testing & commissioning of installation control valve of cast iron body and brass/bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continous alarm when the wetriser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc. of size 150 mm dia as required complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 237 | Supplying and fixing orifice plate made of 6 mm thick stainless steel with orifice of required size in between flange & landing valve of external and internal hydrant to reduce pressure to working pressure of 3.5 kg/cm2 complete with rubber gasket, GI bolts, nuts, washers etc. as required complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 238 | Supplying and fixing of Non-percolating flexible hose (RRL type-A) ISI marked confirming to IS:636, 63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia male and female couplings (Confirming to IS:903) duly bound and riveted to hose pipes with copper rivets and copper wire etc. as required complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . With Stanless steel Coupling |
| 239 | Supplying and fixing first -Aid Fire hose reel wall mounted swinging type with MS construction spray painted in post office Red, conforming to IS 884-1985 with upto date amendments, complete with the following as required. (A) 30 m long 20 mm (nominal internal) dia water hose (B)20 mm (nominal internal) dia gun metal globe valve & nozzle 5mm orifice (C)Drum and brackets for fixing the equipments on wall. (D) Connections from riser with 25 mm dia stop valve (gun metal) & M.S. pipe complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . with High Pressure Braided Rubber Hose as per IS:5132 - 1969 |
| 240 | Supplying and fixing Fire Brigade In let Connection of CI body with Gun Metal/stainless steel male instantaneous inlet couplings complete with PVC blank cap and chain as required for 150mm dia MS pipe connection, conforming to IS 903 as required of following way :-complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 2 Way |
| 241 | Providing and fixing of Gun Metal/stainless steel Fire brigade Suction hose coupling (draw out connection) with nut for female coupling as per IS:902-1974 complete with 100mm dia valve, complete with nut bolts and rubber insertion complete as required complete in all respect.Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 242 | Supplying and fixing of Hose Cabinet made of 1.6 mm thick MS sheet with 6 mm thick glazed glass doors including necessary locking arrangement suitable to accommodate external hydrant with butterfly valve, 2 Nos 15 Mtr. Long Hose pipe, 1 No. branch pipe, mounted onwall duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect, for internal/external hydrant complete as required. Appropriate TestCertificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . size 750 mm x 600 mm x 250 mm |
| 243 | Providing, fixing, testing & commissioning of 15 mm dia size quartzoid bulb type sprinkler heads suitable for 68 degree centigrade rating standard response (UL/FM/LPC/TAC Listed/Approved) chrome plated complete in all respect of the following type complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . Pendant/ Upright type |
| 244 | Providing, fixing, testing & commissioning of 15 mm dia size quartzoid bulb type sprinkler heads suitable for 68 degree centigrade rating standard response (UL/FM/LPC/TAC Listed/Approved) chrome plated complete in all respect of the following type complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .Sidewall Sprinklers (ordinary) |
| 245 | Providing & fixing 10 SWG chrome plated brass 100 mm dia decorative flanges(rossette) / escutcheon plates fixed at junction of Sprinkler piping with the false ceiling complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall beubmitted.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 246 | Supply & Fixing of Fire Man\"s Axe with carbon steel head & rubber moulde handel and confirming to IS :926 with length approx 0.4 M & weight 3.0 Kg. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 247 | SITC of UL 10th edition / EN54 VDS approved IP40 Analog addressableMulti criteria (two optical/Smoke sensor to reduce false alarm ) typePhoto smoke detector with mounting base & LED etc including thecost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved byEngineer in charge. For additional technical parameters of products/work , refer Annexure \"A\" attached with this BSR . with inbuilt isolator or with isolator base |
| 248 | SITC of IP40 Analouge Addressable type Heat Detectors (Thermal Detectors): GRADE-I with solid state design with sensing element combination of fixed type and rate of rise of temperature mounting base & LED shall have UL 10th edition / EN54 VDS approved certification etc including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure \"A\" attached with this BSR . with inbuilt isolator or with isolator base |
| 249 | SITC addresable automatic fire duct detector for monitoring of ventilation ducts with air velocity of 20 m/s which can perform alarm pattern analysis, with even response sensitivity for all fires with smoke development with 1 no outlet tube 7.5 cm long with housing complete , Shall have EN54 /UL Certification including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . with inbuilt isolator or with isolator base. Each 6766.0 |
| 250 | Supply installation testing and commisisioning of Addressable control (input/output) modules/ Relay Module for shutting down lifts, AHU\"s, Acknoledgement of Sprinkler system etc. with potential free contact monitoring Shall have EN54 /UL Certification. including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . with inbuilt isolator or with isolator module |
| 251 | Supply, Installation, Testing and Commissioning of Microprocessor based inteligent, Analogue addressable fire alarm panel with CPU redredundancy & min 640 charactor/ 6\" touch screen display , shall have UL 10th edition / EN54 VDS approved certification, modular, expandable networkable loop Fire Alarm Control Panel with each loop capacity of min 125 detectors per loop with total of 250 detectors & devices with Loop length up to 1.5 KM. Minimum 5000 history eventfacility . Panel shall be Compatible for Seamless integration with PA system and both system should be of the same make. The panel shall have 230 + 5 % volts power supply, Automatic battery charger 24V, sealed lead acid maintanence free battries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during emergency condtion. Loop interface cards, communication module, inbuilt networking port (both RS485 & Ethernet),Serial port for printer, two supervisory inputs,two position key switch and USB port for programming. including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 2-LOOP |
| 252 | Supply , installation testing and commisioning of EN-54 Certified IP based PA controller capable of adding 12 ZONE and expandable upto 50 zones with full digital functionality same with FACP OEM, it shall contain 12 speaker line outputs. 5000 fault warning and event conditions log. Built in message manager for 60 emergency/ business calls up to 60 minutes. It also contains EN-54 certified Call Station with extension keypad to serve minimum 12 zones, gooseneck microphonewith supervised electret microphone, integrated loudspeaker for system sounds, customizable function and speed dial buttons. Possible to use keys (push buttons) for Zone select, source select, level control, emergency on/off, message on/off, failure acknowledge/reset. Call Station is completely supervised by system controller. Power Amplifier of 480 W in a 3U high housing with 70 V / 100 V and 8 ohm outputs,Dual inputs with priority switching,100 V input for slave operation on 100 V speaker line, Mains, battery back-up, including the cost of all accessories ,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect.OEM appropriate test certificate shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 253 | Supply, installing,testing & commissioning of PA system Operator Console of following wattage to be installed with Conventional fire alarm system complete with following capacity , channel mixing amplifier , 1 no cardioids goose neck microphone , 1 no professional grade cassette deck/ CD Player , 16 zone floor selector console , equipment rack complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure \"A\" attached with this BSR . 1x 240 Watt |
| 254 | SITC 6 watt Speaker mounted in M S sheet box with perforated front mesh for PA and Emergency System complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 255 | Supply & Fixing of ABC Type (MAP 50) type powder Fire Extinguisher (Stored Pressure type) of following capacity duly current and valid BIS certification conforming to IS: 15683:2006, with Dry chemical powder used as extinguishing agent should be Mono Ammonium Phosphate50% concentration conforming to IS 14609:1999. OEM will produce supplier certificate complete with squeeze grip release valve, locking arrangement, pressure gauge and bracket including initial fill and wall suspension complete in all respect. Serial no. and date of manufacturing should be embossed or printed on the body of the fire extinguisher. The firm should submit the product certificate from an EN notified body & product performance test report from NABL accredited Lab as per IS 15683. . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 6 kg |
| 256 | Providing, Fixing, of Photo luminescent Self charge EXIT Sign boards of approximate size 12\" x 6\" The colour combination and letter size shall be in accordance with IS: 9457-1980, IS: 12349-1988. complete in all respect. All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 257 | Supplying and drawing FRLS PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC60228. FRLS PVC insulation which provides better fire retardant properties then normal PVC & also emits Low Smoke in case of fire & use type A insulation PVC, in existing conduit including , all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technicalparameters of products/ work , refer Annexure \"A\" attached with this BSR . 2 x 1.5 sq.mm |
| 258 | Supply,Installation, Testing & Commissioning of modular type VariableRefrigerantFlow/VariableRefrigerantVolumeaircooled Outdoorunitssuitable for cooling and heating,having100% hermetically sealed inverter type Scroll/Twin Rotary Compressor(s) with100% inverter Compressor,microprocessorbased Controller,top discharge type condensing unit(s), with R-410 A Refrigerant,vibrationisolators,withsuitablefoundationetc. completeasrequired.Unit Shall work at 54 Degree Ambient condition.The unit shall be suitable to work on 400V +/- 10%, 3Phase,50HzACpowersupply.Theunit shallbefilledwithfirst charge of the refrigerant and ready for use as required. The EER at 100% load with AHRI conditions shall not be less than 3.2 andIncluding OEM supplied Piping connection Kit etc. as required. All as per pre approved by Engineer in charge.OEM to provide Detaion and Power Input data |
| 259 | Supply,installation,testingandcommissioningoffollowing minimumcapacityVRV/VRFHighwalltypeIndoorunitequipped withand comfort washable synthetic media pre-filter, fan section with low noise fan/dynamicallybalancedblower,multispeedmotor,coilsection with DX copper coil, electronic expansion valve, outer cabinet, cord lessremotecontrol,drainpan,necessaryaccessoriesetc.,suitable foroperationon230V±10%,50Hz,singlephaseACsupply, complete as required.The unit shall have automatic force shut down valveincaseoffireonreceivingsignalfromBMSSystem.The coolingcapacityofindoorunitwillbeatairinletconditionsof27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor) All as per pre approved by Engineer in charge.1.0 TR |
| 260 | Supply,installation,testingandcommissioningoffollowing minimumcapacityVRV/VRFHighwalltypeIndoorunitequipped withand comfort washable synthetic media pre-filter, fan section with low noise fan/dynamicallybalancedblower,multispeedmotor,coilsection with DX copper coil, electronic expansion valve, outer cabinet, cord lessremotecontrol,drainpan,necessaryaccessoriesetc.,suitable foroperationon230V±10%,50Hz,singlephaseACsupply, complete as required.The unit shall have automatic force shut down valveincaseoffireonreceivingsignalfromBMSSystem.The coolingcapacityofindoorunitwillbeatairinletconditionsof27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor) All as per pre approved by Engineer in charge. 1.65 TR |
| 261 | Supply,installation,testingandcommissioningoffollowing minimum capacity and external static pressureVRF/VRV ceiling mounted ductable type Indoor unit equippedwith washable synthetic mediapre-filter, fan section with low noise fan/dynamicallybalancedblower,multispeedmotor,coilsection with DX copper coil,electronic expansionvalve, corded/Cordlessremote control, outer cabinet, vibration isolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V ±10%,50Hzcompleteasrequired.Theunitshallhaveautomatic forceshutdown valve incaseoffireonreceiveingsignalfrom BMS System.The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. All as per pre approved by Engineer in charge. 4.5 TR |
| 262 | Supply,installation,testingandcommissioningoffollowing minimum capacity and external static pressureVRF/VRV ceiling mounted ductable type Indoor unit equippedwith washable synthetic mediapre-filter, fan section with low noise fan/dynamicallybalancedblower,multispeedmotor,coilsection with DX copper coil,electronic expansionvalve, corded/Cordlessremote control, outer cabinet, vibration isolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V ±10%,50Hzcompleteasrequired.Theunitshallhaveautomatic forceshutdown valve incaseoffireonreceiveingsignalfrom BMS System.The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. All as per pre approved by Engineer in charge.5.8 TR |
| 263 | Supply,installation,testingandcommissioningoffollowing minimum capacity and external static pressureVRF/VRV ceiling mounted ductable type Indoor unit equippedwith washable synthetic mediapre-filter, fan section with low noise fan/dynamicallybalancedblower,multispeedmotor,coilsection with DX copper coil,electronic expansionvalve, corded/Cordlessremote control, outer cabinet, vibration isolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V ±10%,50Hzcompleteasrequired.Theunitshallhaveautomatic forceshutdown valve incaseoffireonreceiveingsignalfrom BMS System.The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. All as per pre approved by Engineer in charge. 7.1 TR |
| 264 | Supply,installation,testingandcommissioningoffollowing minimum capacity and external static pressureVRF/VRV ceiling mounted ductable type Indoor unit equippedwith washable synthetic mediapre-filter, fan section with low noise fan/dynamicallybalancedblower,multispeedmotor,coilsection with DX copper coil,electronic expansionvalve, corded/Cordlessremote control, outer cabinet, vibration isolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V ±10%,50Hzcompleteasrequired.Theunitshallhaveautomatic forceshutdown valve incaseoffireonreceiveingsignalfrom BMS System.The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. All as per pre approved by Engineer in charge. 8.0 TR |
| 265 | Supply,installation,testingandcommissioningoffollowing minimum capacity 4-way flow VRV/VRF Compact cassette or regular Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor,coilsection with DXCoppercoil,electronicexpansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation,Corded/Cordless remotecontroletc., suitableforoperationon single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down valve in case of fire on receivingsignalfromBMSSystem. Thecoolingcapacityofindoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor). All as per pre approved by Engineer in charge.1.5 TR Compact type |
| 266 | Supply,installation,testingandcommissioningoffollowing minimum capacity 4-way flow VRV/VRF Compact cassette or regular Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor,coilsection with DXCoppercoil,electronicexpansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation,Corded/Cordless remotecontroletc., suitableforoperationon single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down valve in case of fire on receivingsignalfromBMSSystem. Thecoolingcapacityofindoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor). All as per pre approved by Engineer in charge.2.6 TR |
| 267 | Supply,installation,testingandcommissioningoffollowing minimum capacity 4-way flow VRV/VRF Compact cassette or regular Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor,coilsection with DXCoppercoil,electronicexpansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation,Corded/Cordless remotecontroletc., suitableforoperationon single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down valve in case of fire on receivingsignalfromBMSSystem. Thecoolingcapacityofindoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor). All as per pre approved by Engineer in charge. 3.2 TR |
| 268 | CS-AHU having Prefilter section and Fine/microvee section, 6rows deep DX cooling coil, anddischarge plenum, 120mmwg static pressure. 4000 CFM (10.0 TR ) ESP - 120 mmFOR OT |
| 269 | Supply, installation, Testing & commissioning of VRV/VRF compatible OEM make AHU KIT\" including expansion valve and controller for connecting AHU with VRF. |
| 270 | Supplying and installation of high-pressure grade required size OEM make copper connectionY or T Joints / refnet for liquid and suction line complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV / VRF air conditioning system. All as per pre approved by Engineer in charge. |
| 271 | Gas charging of VRF/VRV system with R410A refrigerant gas. Before gas charging system shall be flushed with high purity Nitrogen Gas to remove carbon content, dirt particles to make sure that there is no chance of mixing any impurity with Refrigerant Gas. Thereafter System shall be tested with Nitrogen Gas at 1.5 Times of working pressure of R410 Refrigerant Gas to ensure leakproof system. Whole system shall be Vacuumed up to 500-micron level which ensures the zero-moisture content level in piping to ensure better cooling efficiency and long life of the system. All as per pre approved by Engineer in charge. |
| 272 | Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified \"Class O\" in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge. 41.1 mm O.D., wall thinkness ≥ 1.4mm (insulation – 19 mm thick) |
| 273 | Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified \"Class O\" in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.34.9 mm O.D., wall thinkness ≥ 1.4mm (insulation – 19 mm thick) |
| 274 | Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified \"Class O\" in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.28.6 mm O.D., wall thinkness ≥ 1.2mm(insulation – 19 mm thick) |
| 275 | Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified \"Class O\" in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.22.2 mm O.D., wall thinkness ≥ 1.0mm (insulation – 19 mm thick) |
| 276 | Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified \"Class O\" in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge. 19.1 mm O.D., wall thinkness ≥ 1.0mm (insulation – 13 mm thick) |
| 277 | Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified \"Class O\" in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge. 15.9 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) |
| 278 | Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified \"Class O\" in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) |
| 279 | Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified \"Class O\" in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge. 9.5 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) |
| 280 | Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified \"Class O\" in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge. 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) |
| 281 | Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.32 mm |
| 282 | Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.25 mm |
| 283 | SITC of shealeded communication cable between indoor and out door units . 2 core x 1.5 Sq.mm |
| 284 | Supply , Installation, Testing and Comissioning of site fabricated ducting made from aluminium sheet conforming to IS:737, Grade 31000fabricated as perIS:655 and as per approved drawings & designs including the cost of hangers, supports , angle , expansion fasteners , closed cell neoprene gasket T&P etc. as required of following thickness. All as per pre approved by Engineer in charge.0.63mm (24 G) |
| 285 | Supply , Installation, Testing and Comissioning of site fabricated ducting made from aluminium sheet conforming to IS:737, Grade 31000fabricated as perIS:655 and as per approved drawings & designs including the cost of hangers, supports , angle , expansion fasteners , closed cell neoprene gasket T&P etc. as required of following thickness. All as per pre approved by Engineer in charge. 0.80mm (22 G) |
| 286 | Supplying, installing, testing and balancing of double louveredof extruded Aluminium Powder coated supply/return air grills of various sizes, Each grill shall be with fixed aerofoil shaped horizontal front bar at 0 deflection and back adjustable vertical louvers, air distribution grid for straightening the air flow through the collar and register including fixing with steel screws etc. complete in all respect. All as per pre approved by Engineer in charge. Supply air grill with key operated volume control damper |
| 287 | Supplying, installing, testing and balancing of double louveredof extruded Aluminium Powder coated supply/return air grills of various sizes, Each grill shall be with fixed aerofoil shaped horizontal front bar at 0 deflection and back adjustable vertical louvers, air distribution grid for straightening the air flow through the collar and register including fixing with steel screws etc. complete in all respect. All as per pre approved by Engineer in charge.Return air grill without volume control damper |
| 288 | Supplying, installing, testing and balancing of extruded Aluminium powder coated Air Diffuser and complete with Flush, 20mm flanges with PVC/neoprene gasket, anti – smudge frame and removable inner core to facilitate the adjustable of air control damper, square/round/ rectangular as required.including fixing with steel screws etc. complete in all respect. All as per pre approved by Engineer in charge. Supply Air Diffuser with Volume Control damper |
| 289 | Supplying, installing, testing and balancing of extruded Aluminium powder coated Air Diffuser and complete with Flush, 20mm flanges with PVC/neoprene gasket, anti – smudge frame and removable inner core to facilitate the adjustable of air control damper, square/round/ rectangular as required.including fixing with steel screws etc. complete in all respect. All as per pre approved by Engineer in charge.Return Air Diffuser without Volume Control damper |
| 290 | Supplying, installing and balancing of extruded Aluminium powder coated fresh air inlet louvers with bird screen & volume control damper fixing with steel screws etc. complete in all respect. All as per pre approved by Engineer in charge. |
| 291 | SITC of canvas connection |
| 292 | Supply , Installation, Testing and Comissioning of site fabricated ducting made from aluminium sheet conforming to IS:737, Grade 31000fabricated as perIS:655 and as per approved drawings & designs including the cost of hangers, supports , angle , expansion fasteners , closed cell neoprene gasket T&P etc. as required of following thickness. All as per pre approved by Engineer in charge. 0.63mm (24 G) |
| 293 | Supply , Installation, Testing and Comissioning of site fabricated ducting made from aluminium sheet conforming to IS:737, Grade 31000fabricated as perIS:655 and as per approved drawings & designs including the cost of hangers, supports , angle , expansion fasteners , closed cell neoprene gasket T&P etc. as required of following thickness. All as per pre approved by Engineer in charge.0.80mm (22 G) |
| 294 | Supply & fixing of external thermal closed-cell Nitrile rubber Insulation material FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified \"Class 1\" in Fire Propagation as per BS 476 Part 6 in form of sheet on duct including cost of adhesive (CPRX Compound) complete as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .13mm thick for indoor Application |
| 295 | Supply & fixing of external thermal closed-cell Nitrile rubber Insulation material FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified \"Class 1\" in Fire Propagation as per BS 476 Part 6 in form of sheet on duct including cost of adhesive (CPRX Compound) complete as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .19mm thick for indoor Application |
| 296 | Supply & fixing of external thermal closed-cell Nitrile rubber Accusticmaterial FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified \"Class 1\" in Fire Propagation as per BS 476 Part 6 in form of sheet on duct including cost of adhesive (CPRX Compound) complete as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .10mm thick for indoor Application |
| 297 | Supply , Installation, Testing and Comissioning of ISO certified company made self contained drinking water coolar with BEE Rated energy efficient hermetic sealed type compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz ac supply,Full stainless steel (S304)bodyand tank , stainless steel water tray,minimum two nos faucets and suitable drainage system complete in all respect with 300mm height MS fabricated and painted plateform. complete in all respect of the following capacity. NABL accredeated / CPRI/ ERDA lab testing reports with OEMcertificate must submitted to engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs |
| 298 | Supply and Installation of Box type EU13 Hepa Filter of 99.997% efficiency down to 0.3 micron particle size installed in zero leakage Aluminium frame as per ISO 14644-1 clean room including sealing and packing material cost like silicon and hardware cost and Labour cost. NABL accredeated / appropriated lab testing reports with OEM certificate must submitted to engineer in charge. . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 305 mm Thick |
| 299 | Supply, Installation, Integration, Testing, & Commissioning of 4 MP Fixed Lens Network IR Bullet Camera with SD Card as per requirement, scope of work, technical specification & complete in all respect as per the satisfaction of Engineer in Charge with 3 years onsite OEM support. |
| 300 | Supply, Installation, Integration, Testing, & Commissioning of 4 MP Vari-focal Motorized Bullet camera with SD card as per requirement, scope of work, technical specification & complete in all respect as per the satisfaction of Engineer in Charge with 3 years onsite OEM support. |
| 301 | Supply, Installation, Integration, Testing, & Commissioning of 4 MP Fixed Lens Network IR Dome Camera with SD Card as per requirement, scope of work, technical specification & complete in all respect as per the satisfaction of Engineer in Charge with 3 years onsite OEM support. |
| 302 | Supply, Installation, Integration, Testing, & Commissioning of 64 Channel H.265 Network Video Recorder upto 8 SATA III, with 6 TB -2 NOS HDD, as per requirement, scope of work, technical specification & complete in all respect as per the satisfaction of Engineer in Charge with 3 years onsite OEM support. |
| 303 | Supply, Installation, Integration, Testing, & Commissioning of 8 Port Gigabit POE Network Switch as per requirement, scope of work, technical specification & complete in all respect as per the satisfaction of Engineer in Charge with 3 years onsite OEM support. |
| 304 | Supply, Installation, Integration, Testing, & Commissioning of 42\"Led Monitor as per requirement, scope of work, technical specification & complete in all respect as per the satisfaction of Engineer in Charge with 3 years onsite OEM support. |
| 305 | P & F Automated operated hermetically sealing sliding main door on Operation Theatre of approximate size, 2100mm (H) X 1000 (W) and 2100mm (H) X 1500 (W) It Door should be having a track system wherein the door blade is guided under a 45° angle with approximately 6mm deep indentations at the closed position. The door should having a special inside & outside Stainless Steel lever handle that lifts out the door blade from its hermetic closing position, thus should allow even very heavy doors to be opened effortlessly, manually .The door should be encased within an extruded anodized 2.5 mm thick aluminum profile frame all around the door blade, and should be with solid high pressure laminate on both sides bonding firmly for rigidity. The door should have special nylon top rollers with double roller bearings, to enable the door to slide smoothly & silently. The door blade should be having a special 3-tier specially designed 3 side heavy duty replaceable EPDM gaskets, for the hermetic sealing on the wall frame. The bottom sealingshould be with a 2-tier heavy duty EPDM gasket to flush with the finished floor. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy