| 1 | Earth Work Excavation for foundation in all types of soils and sub soils to full depth (such as Soils in Rock / Silt / Light Black Cotton Soil / Ordinary Soil ) except in rock requiring blasting but inclusive of shoring, shuttering and bailing out water wherever necessary and refilling the sides of foundation with excavated earth other than sand in layers of 150 mm thick well rammed and consolidated, depositing the surplus earth in places shown by the Departmental Officers with initial lead of 10 m and initial lift of 2 m. Complete as per TNSS23 & 24, V, VI (S2), VII, 9,10 |
| 2 | Plain Cement Concrete of mix 1 : 4 : 8 (One Cement four sand eight aggregates) using 40mm gauge hard broken including cost conveyance of all materials to site including formwork and centering labour charges, transporting and placing in position including shoring, strutting, forming protective bunds, cofferdams bailing out of water labour for mixing compacting, finishing and curing, working at depths, tools and plants and incidental charges such as sheeting, shoring and bracing and their subsequent removal etc., complete as per standard specification. |
| 3 | Supplying anderrectingsteel centering including necessary supportsfor plain surfaces for Reinforced Cement Concrete works such as Column footing, Column pedestals, plinth beams, grade beams, staircase steps, etc which requires only nominal strutting using mild steel sheets of size 90mm x60mm and 10Bg stiffened with welded mild steel angles of size 25mm x 25mm x 3mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm center to center or at suitable intervals etc complete in all floorsComplying with standard Specification( TNSS NO or NBC No 30(S) 86 86 A V, VI(S3)VII |
| 4 | Side wall |
| 5 | Beam Rcc Slab |
| 6 | Column |
| 7 | Providing and laying in position Standardised Concrete Mix M-25 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 350Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone sand (M- Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. |
| 8 | Under Ground |
| 9 | Ground Floor |
| 10 | Supplying and Fabrication of Steel and placing in position MS / Ribbed tor steel grills for RCC works as per design given including cost of steel and GI binding wire in Floors etc., Complete complying with standard specification in force per Kilogram. |
| 11 | Brick Work in Cement Mortor 1:5 Mix (one cement, five sand) using new best Second Class Bricks of size9 ” x 4 3/8 “x 2 3/4 ”from approved quarry including cost and conveyance of all materials to site. Loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications. |
| 12 | Upto Basement |
| 13 | Ground Floor |
| 14 | Brick partition walls of 11.50cm thickness using best quality country bricks of size 8-3/4\" x 4-1/4\" x 2-3/4\" in Cement Mortar 1:3 mix (One cement and three sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) |
| 15 | SpecialPlasteringinC.M. 1 : 3 ( One cement, three sand) to10 mmthickincludingallcostandconveyance ofallmaterialstositeincludingcostofcementwhichwillbepurcharedlocallybythe contractor andconveyanceofthesametotheactualworksiteandcostformworkincludingwatering curingandallleadsofgoodpotablewaterandallother. |
| 16 | PlasteringinC.M. 1 : 5 (1cement 5sand)to12 mmthickincludingallcostandconveyanceofallmaterials tositeincludingcostofcementwhichwillbepurcharedlocallybythecontractor and conveyanceofthesametotheactualworksiteandcostformworkincludingwatering curingandallleadsofgoodpotablewaterandallother. |
| 17 | Supplying and Painting thewalls with TwoCoatsWeather sealedExterior emulsion Paint as instructed by the departmrntal officers includingPreparation of surface curing, etc complete in all floorscomplying with standard specification. ( The Colour and shade of the paint shall be got approved by the departmental officers.) |
| 18 | Floor Finishing First Quality Design Ceramic tiles of All colours of sizes 305mm x 305mm x 6mm. laid in cm 1:3 mix 10mm thick and pointing with white cement using 0.4kg/sqm including finishing the joint and pointing flush with tiles surface etc complete |
| 19 | Manufacturing supplying and fixing ofMILD STEEL DOOR made out of 50 x 50 x 6 mm M.S angle for outer frame,35 X 35 X 5mm M.S.Angle for outer frame of shutter. The entire shutter area shall be covered with CRC sheets (18 G) with 5Nos, of stiffners using M.S.Flats of size 25 X 6mm at equal intervals horizontally. The corners of the frames and shutter with CRC sheets shall be welded by adopting flash butt welding or any other suitable method. Provision towards 3Nos, of Hinges incase of single shutters / 6Nos,of Hinges incase ofDouble shutters of 125 X 31 X 1.25mm size placed at appropriate intervals and provisions shall be made for Tower bolts 2Nos, Aldrop 1No. The frame shall be provided with 6Nos,of Hold fast of 200mm length using 50 X 6mm M.S.Flat. The entire frame and shutter shall be provided with one coat of red oxide primer including cost of hold fasts,hinges, locking arrangements, handles wind appliences etc., complete and as directed by the departemental officers. |
| 20 | Manufacturing supplying and fixing ofMILD STEEL Window made out of 40 x 40 x 6 mm M.S angle for outer frame, 35 X 35 X 5mm M.S.Angle for outer frame of shutter. The entire shutter area shall be covered with CRC sheets ( 18 G ) with 5Nos,of stiffners using M.S.Flats of size 25 X 6mm at equal intervals horizontally. The corners of the frames and shutter with CRC sheets shall be welded by adopting flash butt welding or any other suitable method. Provision towards 3Nos, of Hinges incase of single shutters / 6Nos,of Hinges incase ofDouble shutters of 125 X 31 X 1.25mm size placed at appropriate intervals and provisions shall be made for Tower bolts 2Nos, Aldrop 1No. The frame shall be provided with 6Nos,of Hold fast of 200mm length using 50 X 6mm M.S.Flat. The entire frame and shutter shall be provided with one coat of red oxide primer including cost of hold fasts,hinges, locking arrangements, handles wind appliences etc., complete and as directed by the departemental officers. |
| 21 | Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. |
| 22 | Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer.The colour & quality of tiles should be got approved by Municipal Engineer before use on work |
| 23 | Dadooing sides of walls with Glazed design tiles of size 305 x 200 x 6mm set in Cement Mortar 1:3 ( One cement, three sand) 20mm thick and pointed with the same colour cement including cost and conveyance of all materials, labour charges complete as per standard specification. |
| 24 | Supply and fixing of Solid PVC door shutters with frameusing 19 guage 19mm Ms square tubes for styles and outer frame 15mm MS square tubes for top lock bottom rails. The steel square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutterrs using 5mm thicksolid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. the overall size of styles shall be 50mm x 30mm. the overall size of top rail, lock rail and bootom rail shall be 75mm x 30mm. the ovrall size of frames shall be 50mm x 45mm with suitable rebate for housing the shutters. etc., complete complying with standard specification (PWD SOR 2022-23 P.No.43) |
| 25 | Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work |
| 26 | Supplying and laying of StainlessSteel hand rails fabricated with 50mm dia 40mm dia and 20mm dia stailess steel pipe used in Ramp sideof hand rails and four of stainless steel pipe are welded harijontally at the middile of the hand rails made 18mm S.S. pipe & elegant Stainless steel balls are provided in required places of hand rail as directed by the departmental officers. The size including cost of material welding with stainless steel grinding and good polishingand fixed in the hand rails with good position as directed by the departmental officers |
| 27 | Painting two coats with Ready Mixed Enamel Paint over the new iron works of approved quality and colour without priming coatincluding the cost all materials etc.,complete, in all floors. |
| 28 | Earthing as per the ISI specification with an earth electrode of 2.10 metre Class \"B\" GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry (SD-225) |
| 29 | Supply and run of 2 of No.8 SWG GI wire for guarding with cradle with No.8 SWG GI wire at the equal interval of1.5 metre (SD-75) |
| 30 | Supply and fixing of 3 phase 4 wire 4 way ICDB of 32A per way with 100A TPNMC switch with suitable trunking box MS cable entry boxes and internal connection on suitable angle iron frame work with earth connection etc., complete as per standard specification - (SD 152 PWD Electrical Data) |
| 31 | Supply and run of 2 of 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour(SD-55) |
| 32 | Supply and run of 2 of 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection 14 SWG TC wire with painting of suitable colour(SD No :54) |
| 33 | Supply and fixing of TNEB meter board suitable for 32A three phase service connection with 3 Nos. 32A fuse unit (500V) 32A neutral link and earth link (1\" x 1/8\" copper flat) on TW plank of size 600mm x 450mm x 19mm with supporting TW reepers of 1\" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit(SD No :129) |
| 34 | Supply and run of 4 of 16 sq.mm.PVCArmoured Cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with continuous earth wire connection of 14 SWG TC wire with painting of suitable colour(SD No :217) |
| 35 | Supply and run of 4 of 10 sq.mm.PVCArmoured Cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with continuous earth wire connection of 14 SWG TC wire with painting of suitable colour(SD No :216) |
| 36 | Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A FT switch with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed light point / fan point (for electronic regulator)(SD No :23) |
| 37 | Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet cover for 5A 3 pin non inter locking wall socket with 5A flush type switch with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point(SD No :38) |
| 38 | supply and fixing of 18W LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. (SD No :441) |
| 39 | Supply and Installation of Air-Conditioner with Copper Coil 1.5TR Split Type AC Unit- 3 Star Rated including all labour Charges etc…. |
| 40 | Supply and Installation of 4 KVA capacity Automatic Voltage Stabilizer with time delay relay including all labour Charges etc…. |
| 41 | SupplyingandFixingin position best approvedof BIS quality P.V.C pipe having a pressure of 4Kg / Sq.cm including cost of necessary PVC shoe,PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails etc, and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc, complete. The rate shall be inclusive of cast of removable cast iron grating. The PVc pipe shall be fixed in wall with special type of \"U\"clamp at the centre of the pipe line in addition to those for more than 3.00mt pipe length etc,CompleteComplyingwithStandardSpecifications. |
| 42 | 110mm dia Pipe |
| 43 | 90mm dia Pipe |
| 44 | Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \"B\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). |
| 45 | Supplying and fixing in position colour Europen water closet with low level flushing tank of 10 lit capacity of best quality and approvel make with 100mm \"p\" or \"s\" trap with double flapped rigid PVC seat cover with CP brass etc. Complete complying with standard specifications and as directed by the department officers ( EWC should got approvel by the executive work before use on work.) |
| 46 | Providing & fixing PVC RAIN WATER DOWNFALL PIPE of the following dia with necessary T.W.Clamps Plugs Shoes, Bends, other clamps, screws nails, etc.., complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak wood Plugs use id 150x25mm in front & 200x75mm in rear (wall side) with a depth of 110mm dia PVC pipe (4Kg/sqcm) |
| 47 | Supply and fixing in position 15mm dia brass CP screw down tap/pillar tap (heavy duty) of approved make confirming to BIS Specifications and quality including cost of shellac thread etc complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works) |
| 48 | SD Tap |
| 49 | Pillar Tap |
| 50 | Supply, laying and jointing PVC Pipes (having wotking pressure 10kg/Sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC Specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall or drilling holes in the roof and making good the dismantled portion to original condition with necessary scaffolding charges, etc.. complete complying with standard specifications. The PVC pipes shall be got approved by Executive before use on works |
| 51 | 25mm dia |
| 52 | 32mm dia |
| 53 | Supplying and fixing in position PVC Specials of the following dia and types of approved quality confirmingto BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and redoing the dismantled portion to original condition etc.., complete complying with standard specifications (The PVC Specials should be got approved by the Executive Engineer before use on works |
| 54 | PVC Elbow |
| 55 | 110mm dia |
| 56 | 90mm dia |
| 57 | PVC Elbow with Door |
| 58 | 110mm dia |
| 59 | 90mm dia |
| 60 | PVC Tee |
| 61 | 110mm dia |
| 62 | 90mm dia |
| 63 | PVC Tee with single door |
| 64 | 110mm dia |
| 65 | 90mm dia |
| 66 | PVC \"Y\" with single door |
| 67 | 110mm dia |
| 68 | 90mm dia |
| 69 | Supplying and delivery of following PVC pipe and specials with ISI mark including cost and convience of materials etc completed.. |
| 70 | Coupler |
| 71 | 25mm dia |
| 72 | 32mm dia |
| 73 | Elbow |
| 74 | 25mm dia |
| 75 | 32mm dia |
| 76 | Bend |
| 77 | 25mm dia |
| 78 | 32mm dia |
| 79 | Tee |
| 80 | 25mm dia |
| 81 | 32mm dia |
| 82 | End Cap |
| 83 | 25mm dia |
| 84 | 32mm dia |
| 85 | Reducer |
| 86 | 20mm x 15mm |
| 87 | 25mm x 20mm |
| 88 | 32mm x 25mm |
| 89 | Reducer Tee |
| 90 | 20mm x 15mm |
| 91 | 25mm x 20mm |
| 92 | 32mm x 25mm |
| 93 | Reducer Elbow |
| 94 | 20mm x 15mm |
| 95 | 25mm x 20mm |
| 96 | 32mm x 25mm |
| 97 | Jet Nipple |
| 98 | 25mm dia |
| 99 | 32mm dia |
| 100 | Supplying and fixing in position first quality and approved variety of Gun Metal Gate Valve (Heavy type) with I.S.I.mark of the following sizes including cost of Shellac , thread etc,.including labour for cutting and threading of G.I.Pipes etc.,complete complying with standard specifications for both internal and external water Supply arrangements. |
| 101 | 25mm Gun Metal Gate Valve |
| 102 | 32mm Gun Metal Gate Valve |
| 103 | Supply and fixing of CI Nahini / Floor Trap with stainless Steel Gratings - 100 mm x 75 mm including all charges etc, complete as per standard specification. |
| 104 | Supplying and fixing of 1000 Liters capacity HDPE tank with IS specification IS 10701/96 the tank is meant for outdoor (or)indoor use complete with removable hinged top locking arrangement and to make provision to fix water supply pipe lines, necessary man hole with cover and including all PVC specials pugs, screws nails to fix the tank etc., complete and the tank should fixedfirming as directed by the departmental officers.The rate shall be inclusive of all materials, labour conveyance hoisting and fixing charges etc. (The water tank should be got approved by the EEbefore use on work. |