Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead of area 3 sqm and below complete all as specified and directed. |
| 2 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead of area 3 sqm and above complete all as specified and directed. |
| 3 | Material and labour for uPVC factory made, white colour louvered ventilators made of extruded profiles with figured / frosted glass louvers; profiles of frames and sash will be mitred cut and fusion welded at all corners including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2 ± 0.2mm thick galvanised steel profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners complete as directed by the Engineer-in-Charge. |
| 4 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door / window / clerestory windows & other frames / chowkat size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (suspension grade), calcium carbonate and natural fiber (wood powder / rice husk / wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with mitre joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite / borer proof, water / moisture |
| 5 | proof and fire retardant and fixed in position with M.S hold fast / lugs / SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S hold fast / lugs or SS dash fasteners shall be paid for separately).Note: WPC solid door / window frames, minus 5mm tolerance in dimensions i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 6 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of 35 mm thick size comprising of virgin polymer of K value 58-60 (suspension grade), calcium carbonate and natural fibers (wood powder / rice husk / wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite / borer proof, water / moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws all as per direction of Engineer-in-Charge.Note: Stainless steel butt hinges with S.S screws shall be measured and paid separately. |
| 7 | Providing and fixing aluminium tower bolts 200 x 10 mm, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc., complete all as specified and directed. |
| 8 | Providing and fixing aluminium sliding door bolts 250 x 16 mm, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade with nuts and screws etc., complete all as specified and directed. |
| 9 | Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc., brass butt hinges (light / ordinary type) : 100 x 70 x 4 mm complete all as specified and directed. |
| 10 | Providing and fixing aluminium handles 125 mm, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc., complete all as specified and directed. |
| 11 | Providing and fixing Fibre Glass Reinforced plastic (FRP) door frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fibre glass from all sides. M.S. stay shall be provided at the bottom to steady the frame complete all as specified and directed. |
| 12 | Providing and fixing 30 mm thick glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture made with fire-retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames complete all as specified and directed. |
| 13 | Supply and fix, zebra blinds for windows with all necessary fittings all complete as specified and directed. |
| 14 | Supply and fix, 12 mm thick plywood for wall panelling and fixing 4 mm thick veneer & premium wooden beadings by levelling and framing of the wall with PU interior polishing of veneer complete all as specified and directed. |
| 15 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead for thickness of tiles 10 mm to 25 mm complete all as specified and directed. |
| 16 | Providing and laying vitrified floor tiles in 800 x 800 mm size (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete all as specified and directed. |
| 17 | Providing and laying vitrified tiles, size of tile 600 x 600 mm (thickness to be specified by manufacturer) with water absorption less than 0.08% and conforming to I.S. 15622 of approved make in all colours & shade in skirting, riser of steps over 12 mm thick backing coat of cement mortar 1:3 (1 cement : 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc., complete all as specified and directed. |
| 18 | Providing and laying Glazed vitrified tiles Matt / Antiskid finish of size tile 600 x 600 mm in floor(thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved brand & manufacturer in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily complete all as specified and directed. |
| 19 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kgs per sqm including pointing in white cement mixed with pigment of matching shade complete all as specified and directed. |
| 20 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to edges to give high gloss finish etc., complete at all levels. Granite stone slab colour Black, Cherry / Ruby red area of slab over 0.50 sqm complete all as specified and directed. |
| 21 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead complete all as specified and directed. |
| 22 | Providing and laying polished granite stone flooring in required design and patterns in linear as well as curvilinear portions of the building with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc., all complete as specified and directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry / Ruby Red or equivalent. |
| 23 | Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge in cement mortar complete all as specified and directed. |
| 24 | Material and labour for Half brick masonry with non modular fly ash bricks of class designation 10, conforming IS : 12894 in super structure above plinth and upto floor V level cement mortar 1 : 4 (1 cement : 4 coarse sand) complete all as specified and directed. |
| 25 | Material and labour for Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level upto floor level in cement mortar 1:6 (1 cement : 6 coarse sand) : with F.P.S. (non modular) bricks complete all as specified and directed. |
| 26 | Material and labour for 12 mm cement plaster of mix : 1:6 (1 cement : 6 fine sand) complete all as specified and directed. |
| 27 | Material and labour for newly plastered internal wall and applying two coats of white cement based putty including sand papering the puttied surfaces to form an even and smooth surface and applying two coats of plastic emulsion over a coat of interior primer complete all as specified and directed. |
| 28 | Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering including disposal of rubbish to the dumping ground all complete as per direction of Engineer-in-Charge. |
| 29 | Material and labour for filling the existing cracks on plastered surfaces of walls by using Dr. Fixit Crack-X Shrinkfree compound including preparation of surfaces before application by opening the cracks and cleaning off the dust, dirt etc., for ease of application of paste all as per manufacturer\"s instructions and making good surfaces complete all as specified and directed. |
| 30 | Chipping of unsound / weak concrete material in patched for 15mm average thickness from slabs, beams, columns etc., with manual Chisel and/or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc., complete with necessary scaffolding / staging and disposal of debris for all lead and lifts all complete as per direction of Engineer-in-Charge. |
| 31 | Cleaning of reinforcement in patches from rust from the reinforcing bars of dia upto 12mm to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry all complete as per direction of Engineer-in-Charge. |
| 32 | Material and labour for mixing and applying SBR polymer modified cement mortar in proportion of 1:4 (1 cement : 4 graded coarse sand with polymer minimum 2% by wt. of cement used) 15 mm average thickness each in three layers of as per specifications and directions of Engineer-in-Charge.Note: Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument. |
| 33 | Material and labour for White washing with lime to give an even shade : New work (three coats) complete all as specified and directed. |
| 34 | Demolishing cement concrete manually / by mechanical means in sunken flooring including disposal of material within 50 metres lead as per direction of Engineer-in-Charge. |
| 35 | Material and labour for filling light weight cinder as in sunken floors complete all as specified and directed. |
| 36 | Material and labour for cleaning the inner concrete surface of the sunken floor using chisel and wire brush, remove all dirt, dust, loose particles by using air blower, identify the honey comb and deteriorated areas if any which are to be patch repaired. Patch repairing all such areas by using SBR polymer modified cement mortar in proportion of 1:3, 15mm average thickness followed by providing and applying two coats of high performance elastomeric cementious water proofing coating.[Make of water proofing coat: \"Brushbond RFX\" components (i.e. mixture of powder 15 kgs + Nitobond BBX 4.8 litres + clean fresh water 3 litres) manufactured by M/s Fosroc Chemicals India (P) Ltd. / equivalent in \"Dr Fixit\" / \"Harjas Coatings & Polymers\" / \"Krishna Conchem Products (P) Ltd\" & Make of polymer modifier: \"Nitobond SBR\" of make: \"Fosroc\" or equivalent in \"Dr Fixit\" / \"Harjas Coatings & Polymers\" / \"Krishna Conchem Products (P) Ltd\"]. |
| 37 | Supply only Water proofing compound complete all as specified and directed. |
| 38 | Removing building materials other than soil to a distance 500m but not exceeding 1.0Km beyond the lead including in rates including loading, unloading ant stacking at destinations complete all as specified and directed. |
| 39 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., upto floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) complete all as specified and directed. |
| 40 | Material and labour for Steel reinforcement for R.C.C. work ready to use \"cut and bend\" rebars of approved make from factory / workshop to construction site including placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more complete all as specified and directed. |
| 41 | Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead complete all as specified and directed. |
| 42 | Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge.(a) Internal work - Exposed on wall. |
| 43 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 15 mm nominal dia pipes having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings this includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing ofjoints complete as per direction of Engineer-in-Charge. |
| 44 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 20 mm nominal dia pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings this includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. |
| 45 | Supply and fixed in repairs bib taps, 15mm bore, cast copper alloy, chromium plated with crutch handle, short body with wall flange, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 46 | S&F in repairs 15mm dia pillar taps, cast copper alloy with long neck, chromium plated fancy type with aerator, screwed down high pressure with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 47 | Supply and fixed in repairs 15mm dia angle valve cast copper alloy fancy type chromium plated with crutch handle and wall flange complete all as specified and directed. |
| 48 | Supply and fixed in repairs cast copper alloy, chromium plated 2 way bib cock 15mm dia with crutch handle with wall flange complete all as specified and directed. |
| 49 | Supply and fixed in repairs CP push taps for urinals with connecting CP pipes complete all as specified and directed. |
| 50 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer-in-Charge. |
| 51 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore complete all as specified and directed. |
| 52 | Supply and fix, rotational moulded polyethylene water storage tanks, double layered of capacity 2000 ltrs (cylindrical vertical with closed top) hoisted and fixed in position complete including necessary GI tank nipples, taking down existing unserviceable tank all as specified and directed by Engineer-in-Charge. |
| 53 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore complete all as specified and directed. |
| 54 | S.C.I. gully or nahani grating 100 mm dia complete all as specified and directed. |
| 55 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 100 mm nominal dia pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings this includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. |
| 56 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti-microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-in-Charge [PN - 16 Pipe, 40mm OD (SDR-7.4)]. |
| 57 | Material and labour for repairs counter top wash basin of size 560mm x 455mm embedded in granite over RCC slab of colour white complete all as specified and directed. |
| 58 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern including flush pipe with manually controlled device (handle lever) conforming to IS : 7231 with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid complete all as specified and directed. |
| 59 | Providing and fixing white vitreous china flat back half stall urinal of size 580 x 380 x 350 mm with white PVC automatic flushing cistern with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required : single half stall urinal with 5 litre P.V.C. automatic flushing cistern complete all as specified and directed. |
| 60 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished of size 75 x 50 cm deep and 1.8 cm thick fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-Charge |
| 61 | Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete all as specified and directed. |
| 62 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms complete all as specified and directed. |
| 63 | Supply and fixed in repair brass chromium plated soap dish complete all as specified and directed. |
| 64 | Taking down old unserviceable old PVC toilet outlet pipes of 75/110mm dia complete with clamps & fittings complete all as specified and directed. |
| 65 | Material and labour for complete removal of existing treatment from internal wall and applying two coats of white cement based putty including sand papering the puttied surfaces to form an even and smooth surface and applying two coats of plastic emulsion over a coat of interior primer complete all as specified and directed. |
| 66 | Material and labour for Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : one coat on old work complete all as specified and directed. |
| 67 | Material and labour for Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : one coat on old work complete all as specified and directed. |
| 68 | Taking down existing roof treatment of any description including roof plaster and removing the debris to a distance exceeding 500m and depositing out side MD land complete all as specified and directed. |
| 69 | (a) Material and labour for mechanical cleaning of surface to make it free from any bituminous residue / dirt, oil and grease etc all as specified and directed by GE / Engineer-in-Charge.(b) Material and labour for cracks treatment by cutting open cracks and cleaning it from dirt / loose materials etc and filling with polyurethane based sealant with and including application of PU based primer all as directed by GE / Engineer-in-Charge.(c) Material and labour for applying water based polyurethane modified dispersion (single component, cold applied, non toxic, VOC complaint) in 03 coats including 01 coat of primer of same materials after dilution of water at 50% or specific primer matching same materials as per manufacturer specification and as directed by GE / Engineer-in-Charge. |
| 70 | Properties of Polyurethane based chemical shall confirm to following Technical Parameters:-(i) Highly Elastic.(ii) UV Resistance.(iii) Adhesion to concrete.(iv) Tensile strength-not less than 2.0 N/Sq.mm for free film.(v) Elongation-not less than 300%.(vi) Solid content by weight-not less than 60%. |
| 71 | (vii) Air / water permeability BSEN 12390 at 5 bar -72 hours should be NIL and minimum dry film thickness of water proofing membrane must be 1.0 mm.(viii) Accelerated weathering (ASTM453) : Pass 1000 hours.(ix) Reaction to fire-non inflammable. |
| 72 | Supply and fixed in repairs of raised false flooring with enhanced load bearing capacity, higher footprint area on pedestal head leading to enhanced stability & improved load carrying capacity with no overlapping of panels as per below specifications:-1) floor panel of size 600 x 600 mm.2) The panel is laminated by edge beading ESRG system.3) Floor height of 18 inches.4) UDL of 650 kg/sqm.5) Point load of 363 kgs.6) With understructure like pedestal head and stringers, plastic caps and screws. |
| 73 | Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling upto a height of 5 m &above the floor level, over first class kail wood strips 25 x 6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame in curved surfaces complete all as specified and directed. |
| 74 | Dismantling aluminium / Gypsum partitions, doors, windows fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material within 50 m lead as directed by Engineer-in-Charge. |
| 75 | Providing and fixing 15 mm thick densified regular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24 x 38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross \"T\" of size 24 x 28 mm made out of 0.33 mm (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm centre to centre to form a grid of 1200 x 600 mm and secondary cross ‘T’ of length 600 mm and size 24 x 28 mm made of 0.33 mm thick (minimum) sheet to be inter locked at middle of the 1200 x 600 mm panel to from grid of size 600 x 600 mm, resting on periphery walls / partitions on a perimeter wall angle pre-coated steel of size (24 x 24 x 3000 mm made of 0.40 mm thick (minimum) sheet with the |
| 76 | help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture in the grid, including, cutting / making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25 x 35 x 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all \"T\" sections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. |
| 77 | Note: Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames / opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tile shall have NRC value of 0.50 (minimum), light reflection > 85%, non-combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK. |
| 78 | Material and labour for provision of toughened glass partition and doors of thickness 12mm with all fittings complete all as specified and directed. |
| 79 | Taking down old point wiring complete for light / fan / socket (5/15 Amps) bell point complete with all light fittings accessories, such as switch sockets 5/15 Amps, ceiling rose including making good to the disturbed surface to match with the existing complete all as specified and directed by Engineer-in-Charge. |
| 80 | Taking down old DBs with MCCB, MCBs of any size and capacity & making good to the disturbed surface to match with the existing complete all as specified and directed by Engineer-in-Charge. |
| 81 | Taking down old sub main wiring / cable of any size and capacity including making good to the disturbed surface to match with the existing complete all as specified and directed by Engineer-in-Charge. |
| 82 | Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required complete all as specified and directed.(a) Group-C |
| 83 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as required complete all as specified and directed. |
| 84 | Supply and fix, suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin, 5/6 A modular socket outlet and 5/6 A modular switch, connections as required complete all as specified and directed. |
| 85 | Supply and fix, suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin, 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections as required complete all as specified and directed. |
| 86 | Supply and fix, 3 pin, 5 A ceiling rose on the existing junction box / wooden block including connections as required complete all as specified and directed. |
| 87 | Supply and fix, modular switch one way 6 Amps on the existing modular plate & switch box including connections but excluding modular plate as required complete all as specified and directed. |
| 88 | Supply and fix, modular switch two way 6 Amps on the existing modular plate & switch box including connections but excluding modular plate as required complete all as specified and directed. |
| 89 | Supply and fix, modular bell push on the existing modular plate & switch box including connections but excluding modular plate as required complete all as specified and directed. |
| 90 | Wiring for circuit / submain wiring alongwith 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required for light point, 5 Amps socket, 16 Amps power socket & sub main wiring complete all as specified and directed. |
| 91 | Wiring for circuit / submain wiring alongwith 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required for light point, 5 Amps socket, 16 Amps power socket & sub main wiring complete all as specified and directed. |
| 92 | Wiring for circuit / submain wiring alongwith 2 x 4 sq. mm + 1 x 4 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required for light point, 5 Amps socket, 16 Amps power socket & sub main wiring complete all as specified and directed. |
| 93 | Wiring for circuit / submain wiring alongwith 2 x 6 sq. mm + 1 x 6 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required for light point, 5 Amps socket, 16 Amps power socket & sub main wiring complete all as specified and directed. |
| 94 | Wiring for circuit / submain wiring alongwith 2 x 10 sq. mm + 1 x 10 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required for light point, 5 Amps socket, 16 Amps power socket & sub main wiring complete all as specified and directed. |
| 95 | Supply and fix, LED lights fitting 1 x 18 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.Make: Crompton Cat No. LCTLRNE-18-CDL (1X1) & techno commercially equivalent of Havells / Bajaj / Philips / JAQUAR. |
| 96 | Supply and fix, LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.Make: Bajaj Cat No. BCLSB10WH & techno commercially equivalent of Crompton / Havells / Bajaj / Philips / JAQUAR. |
| 97 | Supply and fix, LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable sizecomplete all as specified and directed by Engineer-in-Charge.Make: Bajaj Cat No. BZSSQL 36L LED WH GX & techno commercially equivalent of Havells / Crompton / Philips / JAQUAR. |
| 98 | Supply and fix round shape 15 watt, 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp of warm white suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge.Make: Bajaj Cat No. BZSLOnxt 15L LED WH SD & techno commercially equivalent of Havells / Crompton / Philips / JAQUAR. |
| 99 | Supply and fix, (4FT) 20 W LED fitting baten fro surface and wall conduit mounting High Transmissibility diffuser High lumen Output PF > 0.98, thd < 10% wall mounted type fitting with LED tube rod, complete all as specified and directed by Engineer-in-Charge.Make: Bajaj Cat No. BCLAB 20W LED PS & techno commercially equivalent of Havells / Crompton / Philips / JAQUAR. |
| 100 | Supply and fix, LED flood light 120 watt, 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection with impact and corrosion resistant complete with driver and lamp complete with luminous efficacy not less than 120 lm/w complete all as specified and directed by Engineer-in-Charge.Make: Bajaj Cat No. PRAZE F 144L WH NB-A5 TG SD & techno commercially equivalent of Havells / Crompton / Philips / JAQUAR. |
| 101 | Supply and fix, LED luminaire 1ft x 4 ft, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable sizecomplete all as specified and directed by Engineer-in-Charge.Make: Bajaj Cat No. BZRSLL 36L LED GX WH SD & techno commercially equivalent of Havells / Crompton / Philips / JAQUAR. |
| 102 | Supply and fix, 12 way (4 + 36), double door surface / recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required complete all as specified and directed.Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required. |
| 103 | Supply and fix, 8 way (4 + 24), double door surface / recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required complete all as specified and directed.Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required. |
| 104 | Supply and fix, 20 A, 240 V, SPN industrial type socket outlet with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB in sheet steel enclosure on surface or in recess with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required complete all as specified and directed. |
| 105 | Supply and fixed in repair MCCB, AC 415 V, 50 HZ fixed type, capacity 125 Amps, 4 Pole, 36 KA, suitable to be fixed in 4/6/8/12 way TPN DB complete all as specified and directed. |
| 106 | Supply and fixed in repair MCCB, AC 415 V, 50 HZ fixed type, capacity 100 Amps, 4 Pole, 30 KA, suitable to be fixed in 4/6/8/12 way TPN DB complete all as specified and directed. |
| 107 | Supply and fixed in repair MCB DB double door SPN 12 Way with 200 Amps rated copper bus bar complete all as specified and directed. |
| 108 | Supply and fixed in repair MCB DB double door SPN 8 Way with 200 Amps rated copper bus bar complete all as specified and directed. |
| 109 | Supply and fix, amp rating 240V, 10KA \"C\" curve Miniature Circuit Breaker (MCB) of SP 6 to 32 Amps poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 110 | Supply and fix, amp rating 240V, 10KA \"C\" curve Miniature Circuit Breaker (MCB) of SPN 40 Amps poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 111 | Supply and fix, amp rating 240V, 10KA \"C\" curve Miniature Circuit Breaker (MCB) of SPN 32 Amps poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 112 | Supply and fix, MCB TPN 40 Amps, 4 Pole with breaking capacity 10 KA alongwith replacement of old unservceable one complete all as specified and directed. |
| 113 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long (but with charcoal / coke and salt) as required complete all as specified and directed. |
| 114 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required complete all as specified and directed. |
| 115 | Supply and fix, call bell / buzzer complete all as specified and directed. |
| 116 | Material and labour for taking down the split AC indoor unit from false ceiling / wall carefully and making good to the disturbed surface to match with the existing, deposit in MES storeyard and after completion work refixing the indoor units at their existing / new location complete electrical connection as per earlier make it operationalincluding brazing work, insulation, required copper tube & gas charging if required complete all as specified and directed by Engineer-in-Charge. |
| 117 | Material and labour for taking down the cassette type indoor unit from false ceiling / wall carefully and making good to the disturbed surface to match with the existing, deposit in MES storeyard and after completion work refixing the indoor units at their existing location / new location complete electrical connection as per earlier make it operational including brazing work, insulation, required copper tube & gas charging if required complete all as specified and directed by Engineer-in-Charge. |
| 118 | Taking down old LT panel board after disconnecting all electrical connection, cables, MCCBs, MCBs of any size and capacity including making good to the disturbed surface to match with the existing complete all as specified and directed by Engineer-in-Charge. |
| 119 | Supply, install, testing & commissioning of LT panel board CPRI approved, indoor type cubical, pedestal type, floor mounted factory made, dust and vermin proof, IP-65 fabricated out of CRCA sheet not less than 2.0 mm thick fixed on angle iron frame of size 50 x 50 x 6mm conforming to Fe 410-0, front openable double stud hinged with locking arrangements, lock openable by keys having chromium plated 19mm dia fancy lock, louvers and air vent, gasket U type for natural flow of air, complete dust and vermin proof and panel fixed with PCC 1:2:4, type B1 (using 20mm graded stone aggregate) platform 60 cm above the ground level and 45 cm below the ground level, suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz with copper bus bar of 600 Amps painted with powder coated paint having not less than 100 microns over a coat of zinc chrome primer with seven tank process and general construction confirming to IS-8623 of 1993 comprising the following:- |
| 120 | (a) Copper bus bar 600 Amps capacity 4 wire fixed on insulator not less than 1.0 mtr long bus bar - 01 Set.(b) MCCB, 4P, 400 Amps with fixed thermal release 50 KA at 415 Volts (incoming) - 01 No.(c) (Outgoing) MCCB, 4P, 160 Amps with ultimate breaking capacity of 25 KA at 415 Volts with fixed thermal release 36 KA at 415 Volts - 02 Nos.(d) (Outgoing) MCCB, 125 Amps, 4P, 415 Volts AC having rupturing capacity 25 KA - 02 Nos.(e) (Outgoing) MCCB, 100 Amps, 4P, 415 Volts AC having rupturing capacity 25 KA - 02 Nos.(f) Digital Voltmeter 0-500 V of size 96 x 96 mm square with selector switch - 01 No.(g) Digital Ammeter 0 to 1000 A of size 96 x 96 mm square with selector switch - 01 No.(h) R, Y, B phase indicating lamp assembly with HRC fuse protection - 01 No. |
| 121 | (j) CT\"s coils of suitable ratio - 01 Set.(k) MCB SP 5-32 Amps - 02 Nos.(l) MCB DP 32 Amps 16 KA - 02 Nos.(m) On load change over switch 400 Amps - 01 No.(n) 250A, 4P 25KA thermal magnetic trip, microprocessor based alongwith APFC relay, 1 x 100 KVAR and 2 x 50 KVAR capacitor alongwith suitable size MCCB and contactors. |
| 122 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections as required complete all as specified and directed. |
| 123 | Taking down / out old unserviceable aluminium cable / cross linked poly-ethylene (XLPE) insulated, LT cable of any size from pole / laid in trenches / through pipe in road crossings / paths / drains / ducts / floors / along poles / walls / ceilings / equipments etc., complete all as specified and directed. |
| 124 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth in soft / loose soil complete all as specified and directed. |
| 125 | Material and labour for dry sand cushioning to under ground cable intrenches including spreading, levelling and hand punning complete all as specified and directed. |
| 126 | Supply and laying, un-reinforced precast concrete cable cover Class LV type I, size 250 x 150 x 40mm complete all as specified and directed. |
| 127 | Material and labour for cement concrete (1:2:4) type B2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 128 | Cutting trench of width 30cm and depth not exceeding 60cm through road / hard standing for laying cable through GI pipe and returning, filling in including spreading leveling watering and well ramming in layers not exceeding 25cm after laying the cable complete all as specified and directed. |
| 129 | GI tubing light grade 150 mm for cable protection, laid under plinths / floors / roads / paths / culverts or fixed on walls or concealed in walls or along the steel poles by means of M.S.F.I clamps with necessary bolts nuts & washers etc complete all as specified and directed. |
| 130 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in thick all as specified and directed. |
| 131 | Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified by the Engineer-in-Charge. |
| 132 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed. |
| 133 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and directed. |
| 134 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed. |
| 135 | Material and labour for removal and reinstallation of Nitrile rubber insulation on terraces / rooms / corridors of various sizes ranging from 1 1/8\" to 15/8\" & varioustypes of thickness ranging from 9 mm to 19 mm as a cover as required at site and testing after completion of work complete all as specified and directed by Engineer-in-Charge. |
| 136 | Material and labour for wrapping glass cloth & applying UV paint for Nitrile rubber insulation on terraces / rooms / corridors complete with necessary accessories and testing after completion of work complete all as specified and directed by Engineer-in-Charge. |
| 137 | Material and labour for removal reintallation of nitrile rubber insulation on terraces / rooms / corridors of various sizes ranging from 1/4\"\" to 7/8\"\" & various types of thickness ranging from 9mm to 19mm as a cover as required at site and testing after completion of work complete all as specified and directed by Engineer-in-Charge. |
| 138 | Material and labour for wrapping glass cloth & applying UV paint for Nitrile rubber insulation on terraces / rooms / corridors complete with necessary accessories and testing after completion of work complete all as specified and directed by Engineer-in-Charge. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy