| Sl. No. | Item Description |
| 1 | Dismantling of CGI/PGI sheet roofing any gauge and any thickness including ridge, valley gutter etc including removal of rubbish/ demolished materials out of MD landcomplete all as specified and directed. |
| 2 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick ofan colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws omplete all as specified and directed. |
| 3 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws omplete all as specified and directed. |
| 4 | Taking down of old bituminous tarfelt or any other type of roof treatment from roof/ concrete surfacesand cleaning of the roof surface with wire brush to make it free from dust, dirt etc including removal of rubbish/ demolished materials out of MD landcomplete all as specified and directed. |
| 5 | Demolition of cement concrete of any description and in any position not otherwise specifically provided in roof padding concreteetc including removal of rubbish/ demolished materials out of MD landcomplete all as specified and directed. |
| 6 | M&L PCC (1:2:4) type B0 (using 12.5 mm graded stone aggregate) mixing with WPC @ 2% by weight of cement or as per manufacturer\"s instructionsas in levelling course, haunching, coping and similar works over RCC roof surface and RCC over head tank top surface including rounded or chamferred on edges and formwork etc all as specified and directed.Note: Water proofing compound will be measured and paid separately under relevant item in this schedule |
| 7 | M&L Rendering 10mm thickCM (1:4) on roof surfaces mixing with water proofing compound at the rate of 3% by weight of cement and finished even and smooth complete all as specified and as directed Note: Water proofing compound will be measured and paid separately under relevant item in this schedule |
| 8 | M & L Providing,PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in copings,over parapet walls,kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded for chamfered angles and throating,including necessary form work complete all as specified and as directed. |
| 9 | Supply only water proofing compound |
| 10 | M & LProviding water proofing treatement with APP based polymeric membrane minimum weighing 3 kg/ Sqm and minimum 3mm thick reinforced with polyesternon oven fabric ( weight not less than 150gm/Sqm) applyied on one coat of oil based bitumen emulision primer @ 0.3 lit per sqm ( OR as per the directions of manufacturer instructions) including cleaning of surface thoroughly from dust, dirt and projections.Laying of membrane by forced ( torch) application with 10cm overlaps .A coat of blown bitumen 85/25 grade @ 1.2 Kg/sqm to be applied on top of memberane, finally coating the surface with bituminous aluminium paint @ 100gm/Sqm complete all as specified and as directed. |
| 11 | Dismantling wrought iron or mild steel work of any description not otherwise provided for including removal of rubbish/ demolished materials out of MD landcomplete all as specified and directed. |
| 12 | S&F Structural steel work,rolled mild steel as injoist, channel, angle or tee sections, fixed independently without connecting plates, etc., ( cut to ordinary lenghts i.e within 20mm of the length indicated of Fe 410-W ( Gde-E-250) quality A complete all as specified and as directed.Note: The ISMB\"s have to be inserted in wall by replacing damaged existing rafters as in old madras terrace roof including necessary precautionary measures as in supports etc., as directed by the Engr-in charge. |
| 13 | S&F Structural steel work,Roof strusses (framed) trussed,purlins,crane gantries,rails and fastenings and heavy bracket framing,connecting plates, etc., ( cut to ordinary lenghts i.e within 20mm of the length indicated of Fe 410-W ( Gde-E-250) quality A complete all as specified and as directed. Note: The ISMB\"s have to be inserted in wall by replacing damaged existing rafters as in old madras terrace roof including necessary precautionary measures as in supports etc., as directed by the Engr-in charge. |
| 14 | S&F Structural steel work as in plates (plain or chequered)channels, square cut or notched(ordinary and counter sunk)forming holes, without anyattachment etc.Roof strusses (framed) andconnecting plates, etc.,including necessary precautionary measures as in supports etc., complete all as specified and as directed by the Engr-in charge. |
| 15 | S&F Mild steel bolts.purpose made.with hexagonal orforming holes, without anyattachment dia of neck exc 20mm not exc 25mm complete all as specified and as directed. |
| 16 | M & L Preparation ofnew or previously untreted steel or iron surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 17 | Taking down cement plaster of any description and thickness on brickwallsincluding racking out joints, hacking for key, scrubbing down with water etc including removal of rubbish out of MD landcomplete all as specified and directed. |
| 18 | M&L Rendering 10 mm thick CM (1:6) on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 19 | M&LRendering in two coats (10 + 5 mm) 10mm thick in CM (1:6)for first coat and 5mm thick in CM (1:4) forsecond coat mixed with integral water proofing compound ISI Marked @ 2% by the weight of cement on fair faces of brick work or concrete surfaces, even and fair complete all as specified and directed. Note - WPC shall be measured and paid separately |
| 20 | M & L Rendering 10 mm thickCM (1:3) on concrete surfaces such as ceilingor soffits of chhajas etc;finished even and smooth without using extra cement complete all as specified and as directed. |
| 21 | M&L Preparation of newly plasteredwall surfaces and applying two coats of oil bound distemper (oil emulsion) over a coat of alkali resistant primer over 3mm thick wall care putty in two layers complete all as specified and as directed. |
| 22 | M&L Preparation of newly plasteredwall surfaces and applying two coats of distemper (oil emulsion) overa coat of primercomplete all as specified and as directed. |
| 23 | M&L Preparation of newly plasteredwall surfacesand applying three coats of white wash complete all as specified and as directed. |
| 24 | M&L Preparation of newly plasteredceilingsurfaces and applying three coats of white wash complete all as specified and as directed. |
| 25 | M & L Preparing old plastered ceiling surfaces and applying two coats of white wash complete all as specified and as directed. |
| 26 | M&L Preparation of newplastered surfaces on walls, chajjas,filling of hair line cracks and applying white acrylic smooth exterior paint of required shade two coats applied @ 1.67 ltrs/10 sqm over and includingapplyingprimer @ 2.20kg/10 sqm,etc complete all as specified and as directed. |
| 27 | M&LComplete removal of existing treatment onwall surfaces and applying two coats of oil bound distemper (oil emulsion) over a coat of primerover a coat of 3mm thick birla care wall putty etc all as specified and as directed. |
| 28 | Taking down chowkats or frames with shutters (without taking off shutters from frames) of size not exceeding 1.5 Sqms each complete all as specified and as directed |
| 29 | Taking down chowkats or frames with shutters (without taking off shutters from frames) of size exceeding 1.5 sqm and not exc 4.00 sqm each complete all as specified and as directed |
| 30 | S&F Steel windows (fly proof and glazed shutter) made with galvanised steel colour coated/ powder coated ( Base steel as per IS 513 \"D\", galvanised as per IS 277 with zinc of 120gm/sqm) with total coating thickness of 0.60mm. ( outside for glazing and inside gauged shutter) Sections forframe should be of 72mmx55mm, section for mullian should be72mm x 50mm section for shutterframe should be 47mmx 20mm,andsection for fixing glass bead should be 12mm x 12mm and section for fly mesh shutter frame should be 40mm x 20mm mesh fixing should be of 18mm x 0.6mm.Stainless steel wire mesh of 0.45mm dia and ave width of aperture 1.4mm shall be used for fly proofing .4mm thick plain sheet glass to be used for glazing of glazed shuttersincluding 10mm powder coated square saftey grills, locking arrangement and all necesseryaccessories etc, complete all as specified and as directed. |
| 31 | S & F PVC solid ventilator frame size 55 X 47mm with wall thickness of 5mm made out of extruded 5mm PVC sheet, mitre cut at two comers and jointed with 2 Nos of 150mm long brackets of 15 x 15mm MS square tube the two vatted profiles are to be reinforced with 19 x 19mm MS squre tube the 50% of bottom portion is fixed with 4mm pin headed glass and balance 50% of top portion is fixed with 4mm thick pin headed glass lowers and cover with 0.36mm dia stainless steel wire mesh at top portion including necessary PVC beading with screws and 3 Nos 12mm dia MS guard, bars fixed in ventilator frame including two coats of synthetic enamel paint over a coat of red oxide primer to MS guard bars etc complete all as specified and as directed.Make: SINTEX or epuivalent seetings in RAJSHRI , NANDImake as approved by GE. |
| 32 | Dismantling water tanksn. exc 500 litres and removing to store recovery from the contractor as schedule of credit, all as specified and directed. |
| 33 | S&F Rotational moulded polyethyiene water storage tanks (cylindrical vertical with closed top) of 500 liters including tank Nipple suitable for water tank (mininmum weight 15 mm-38gms/20mm-45gms/25mm-65gms capcacity complete 25mm dia bore complete all as specified and as directed. |
| 34 | S & F in repairs 20 mmBall valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. .(Minimum weight20mm-210 gms.complete all as specified and as directed. |
| 35 | Dismantling of wall/ceiling boardas in ceiling and lining of any gauge or any thickness including cover fillets including removal of rubbish/ demolished materials out of MD landcomplete all as specified and directed. |
| 36 | S & F E-grid suspended false ceilng grid system of size 600x600mm with main runner 29x24.7x0.6mm cross tee 29x24.7x0.6mm and wall angle 22.2x22.2x0.50mm. Ceiling suspended with 3mm dia GI wire hanger fixed with steel dash fastner, butter fly clips, hold down clips etc (Main runner, cross tee& wall angle of MS galvanised with PPPCGS) including 4mm thick HPSC self textured design pre primered non asbestos fibre cement building board fixed to false ceiling incl dismantling existing ceiling material etc., complete. |
| 37 | Demolition of brickwork or stone/boulder masonry, built in cement mortar with all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articlesincluding removal of rubbish/ demolished materials out of MD landcomplete all as specified and directed. |
| 38 | M&L Brick work with fly ashbricks old size, straight or curved on plan exceeding 6.0 metre mean radius built in CM (1:6) complete all as specified and as directed. |
| 39 | Dismantling floor, hearth or wall tiling including cementmortar beddingremoving serviceable tiles and rubbish off the premises etc including removal of rubbish/ demolished materials out of MD landcomplete all as specified and directed. |
| 40 | M&L Screed bed or bedding layer of mortar 20 mm thick CM (1:6)for laying floor finishes,etc: complete all as specified and directed. |
| 41 | M&L Rendering 10 mm thk in CM (1:4) as in backing coat of cement plaster for laying of wall tiles etc: complete all as specified and directed. |
| 42 | M&LNon-skidceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqmin floorsetc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match, etc complete all as specified and directed. |
| 43 | M&LNon-skidceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqmin skirting / dado etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match etc.complete all as specified and directed. |
| 44 | M&L Vitrified ceramic tiles 10mm (light shade of square/ rectangular) polished,area of each tilesnot exc 0.36 sqmin floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match etc, complete all as specified and directed. |
| 45 | M&L Vitrified ceramic tiles 10mm (light shade of square/ rectangular) polished,area of each tilesnot exc 0.36 sqmin walls skirting etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match etc.complete all as specified and directed. |
| 46 | S&F Non Skid (coloured) ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etccomplete all as specifed and as directed. |
| 47 | M&LGlazed (Coloured) ceramic tiles in vertical surfaces 300 x 450 x 8 to 9 mm/ 450 x 350 x 8 to 9 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as specified and as directed. |
| 48 | S&FSteel ventilatorswith top hung shutters includinghinges with steel handles and steel peg stay, complete with glazing bars devetailed or weldedall as approved and as directed by the Engr-in-Charge. |
| 49 | S & F 3 mm thick pin headed glass ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.. |
| 50 | Dismantling / taking down PVC/ Cast iron soil /waste pipes 100 mm / 75mm bore including all fitting like bendsetc complete all as specified and directed |
| 51 | S&F PVC (SWR) Nahani /Floor trap, 75 mm dia of out let, plain with grating including jointing to waste pipe with solvent and cement concrete type B1 (1:2:4) & including removing old trap and fixing ofstainless steel grating in ground shape etc complete all as specified and as directed. |
| 52 | S&F75mm bore PVC (SWR)pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps8mm dia with two nuts wall nails etccomplete all as specifed and directed. |
| 53 | S&F110mm bore PVC (SWR)pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps8mm dia with two nuts wall nails etccomplete all as specifed and directed. |
| 54 | S&F 75mm bore PVC (SWR) bends any radius dimnishing pieces or tapers withaccess doors etc, complete all as specified and as directed. |
| 55 | S&F 110mm bore PVC (SWR) bends any radius dimnishing pieces or tapers withaccess doors etc, complete all as specified and as directed. |
| 56 | S&F 75mm bore PVC (SWR) branch piece, single (single Y ) equal or unequalwithaccess doors etc, complete all as specified and as directed. |
| 57 | S&F 110 mm bore PVC (SWR)junction single (single T ) equal or unequalwithaccess doors etc, complete all as specified and as directed. |
| 58 | S&F75mm bore PVC (SWR) vent cowletc, complete all as specified and as directed. |
| 59 | S&F 110 mm bore PVC (SWR) vent cowletc, complete all as specified and as directed. |
| 60 | Supply and fix mild steel flat iron 25 x 3mm as in windtie, etc including necessary drilling holesetc conforming to Fe-290(Gde E-165) all as specified and directed. |
| 61 | S & F 35mm thick flush shutters solid core construction with block board core and ply wood face panels, commercial type on both sides complete all as specified and as directed. |
| 62 | S&FFactory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 50x100mm comprising of virgin PVC polymer of K value 58-60(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applyingPVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules ofelasticity 900 N/mm2 and resistance to spread of flame of Class A category withproperty of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). → Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra, complete all as specified and as directed. |
| 63 | S& F 30 mm thick Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately)complete all as specified and as directed. |
| 64 | S & F 100 mm size Butt hinges extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed type C21complete all as specified and as directed |
| 65 | S & F 150 mm size aluminium handle fabricated type anodized complete all as specified and as directed |
| 66 | S & F 150 mm size aluminium anodized tower boltcomplete all as specified and directed. |
| 67 | S & F 3 mm thick sheet glassordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed |
| 68 | S & F 3 mm thick figured glass pin head type ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed |
| 69 | Taking down steel/aluminium windows/ventilator/Doors complete with frames and shutters (without taking off the shutters) of area not exc 2.00 sqm complete all as specified and as directed. |
| 70 | S&F Standard aluminum sections of any Type as in doors, windows, ventilators, partitons etc, powder coated, cut to size, jointed with cadmium plated steel screws, including necessary jointing clips, rubber packing, neoprene rubber gasket, aluminium snap beading, screws, aluminium fittings, handles, locking arrangement (star lock), Nylon ball bearings and Unit rate quoted shall be deemed to include for sealing the gap of frame with Jamb and Cill (alround) using silicon gel at the rate of 0.05 lit/m for both faces of window etc complete all as specified and as directeNote :- Weight of Aluminum sections for frames and shutters shall be only considered for payment.Cost of other consumables required for the item shall be deemed to be included in the quoted rate.However glass panes / Bakelite sheet only will be measured and paid separately under respective items as supply only.Fixing by element of these items shall be deemed to be included in quoted rate. |
| 71 | Supply only 4.8 mm thicksheet glass, ordinaryquality, ineach pane for n exc 0.50 Sqm each pane for aluminium slidingwindows/ventilatorshutters etccomplete all as specified and directed. |
| 72 | Supply only 4.8 mm thicksheet glass, ordinaryquality, ineach pane forexc 0.50 Sqm each pane for aluminium slidingwindows/ventilatorshutters etccomplete all as specified and directed. |
| 73 | Supply only for 12mm thick Veneered decorative plywood,grade I (with BWR resin) decorative both side faces etccomplete all as specified and as directed |
| 74 | S&F in repair aluminium powder coated (fancy type) tubular curtain rod, 20mm dia, complete all as specified and as directed. |
| 75 | S&F in repair bracket aluminium powder coated (fancy type) for 20 mm dia tubular curtain rod(for item above) complete all as specified and as directed |
| 76 | S&F in repairswash down water closet (pedestal pattern) white and including plastic water closet seat cover as per reqd colour with flat bottom and cover and mild steel chromium plated or aluminium hinging device (excludingflushing cistern ) etc complete all as specified and directed. |
| 77 | S&F in repairs vitreous china wash basin, white, flat back, size 580mm X 450mm including CI brackets, 32mm dia brass chromium plated waste fittingswith long screwed shanks and fly nuts flanged end bedded in red lead cement and other end fixed with & including cutting for & pinning in end of brackets and 15mm bore pillar tap, cast copper alloy fancy type chromium plated, screwed down high pressure complete all as specified and as directed. |
| 78 | S&F PVC Low level flushing cistern 10 ltr capacity, includingwaste pipe, down take pipe, pair of CI brackets and all accessories complete all as specified and as directed. |
| 79 | S&F in repairs of stop valvescast copper alloy, fancy type chromium plated screwed down with long shank and cup (concealed) type, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe and fixed to 15 mm bore pipecomplete all as specified and as directed |
| 80 | S&F in repairs CP angle cock 15mm bore fancy type chromium plated.with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 81 | S&F in repairs CPbib tap 15mm bore fancy type with crutch or butterfly handle, screwedfor iron pipe or for unions and fixed complete all as specified and directed. |
| 82 | M&L 75 mm thick PCC (1:4:8) type D2 (using 40 mm graded stone aggregates) as in subbase to floor complete all as specified and as directed. |
| 83 | M&L Designer rubber moulded chequerred cement concrete tilesof size 200x 200xx25mm ,300 x 300 x 22mmor250 x 250 x 22mm thick with mixture of greyand white cemetn in equal porportions with pigmentsand set and pointed in neat cement slurry in floors over a screed bed or bedding layer 15mm thick CM (1:6) for laying floor finishes etc complete all as specified and as directed. |
| 84 | Taking down the existing unserviceable point wiring of any description, type, size of light or fan or power or two way or bell etc on TW batten or conduit including removal of batten or conduit or gutters or wooden boards or switches or sockets or regulators or light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall or ceiling to match with the existing surfaces complete all as specified and as directed. |
| 85 | M&L Point wiring of any length complete with stranded copper conductor 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLS conforming to IS - 694 multistranded CONCEALED with new sunk type pressed steel terminal boxes suitable for MODULAR switches including fixing/grouting sunken/ surface as per site requirement covered with suitable modular white cover platefor suitable size for mounting of MODULAR switches, regulators and drawing continuous earth wire with one run of 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLSconforming to IS - 694 multistranded copper conductor as earth wire and connecting to common earth dolly for one light point controlled by one, one way switch 5 amps, single pole including making good the disturbed wall surfaces to match with the existing surfaces complete all as specified and as directed. Note: 1. Modular cover plate with frame and modular meta flux bos included in the rate quoted.2. Cutting chasses will me measured and paid seperately. |
| 86 | All as per Item No.85 but one ceiling fan/ exhaust fan point controlled by one, one way switch 5 amps, single pole |
| 87 | All as per Item No.85 above but one 3 pin 5 amps switch socket out let point controlled by one switch on independent board. |
| 88 | All as per Item No.85 above butone 3 pin 5 amps switch socket out let point controlled by one switch on same board. |
| 89 | All as per Item No.85here-in-before butusing 2.5 square millimetre single core copper conductor cable of multistranded PVC insulated unsheathed 1100 volts grade FRLS confirming to IS-694 for 3 pin 15 amps switch socket combination point on independent board and running of 2.5 square millimetre copper conductor PVC insulated cable FRLSas earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and as directed |
| 90 | S & F Modular switch 1 way 6 A, 1 Module capacity 230 volts complete all as specified and directed. |
| 91 | S&F Socket outlet modular type multipurpose 5 Pin, 6 amps, 230 volts 2 Module complete all as specified and directed. |
| 92 | S&F Socket outlet modular type multipurpose 6 Pin, 6/16 amps, 230 volts 2 Module complete all as specified and directed. |
| 93 | S & F Modular switch 1 way 16 A, 1 Module capacity 230 volts complete all as specified and directed. |
| 94 | S & F Modular ceiling fan regulator 5 stepped type heavy duty suitable for BLDC ceiling fans, 2 Module complete all as specified and directed. |
| 95 | S & F Lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings including 9W LED bulb complete all as specified and directed.. |
| 96 | S & F Ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified and directed. |
| 97 | S & F in replacement of wall mounted batten type LED light of 20 watts with aluminium extruded batten and system lumens of 2200 lm minimum with IP & surge protection alongwith driver efficiency >85% and power factor >0.95 , colour rendering index CRI>80 along with integrated driver completeand connecting to the point wiring with necessary flexible copper conductor of multistrand three core of suitable length from fitting to the ceiling rosecomplete all as specified and directed.Make: Philips Model BN021C LED22Sor equivalent model in Havells/Wipro/GE. |
| 98 | S&F LED Light fitting 1x35 Watt230V AC IP 65/66 proctection complete with bracket made out GI pipe med grade 25mm of L Shape 1.5 m long including clamps and nuts botls etc , complete all as specified and as directed. |
| 99 | S&F Sheet metal enclosure MCB DB TPN 4 Way with 200 Amps rated bus bar of 415 Volts, double door with magnetic locking system for fixing MCB’s / isolators including taking down existing old unserviceable MCB DB complete all as specified and as directed. |
| 100 | S & FSheet metal enclosure MCB DBSPN 8 way with 200 Amps rated bus bar of 240 Volts, double door with magnetic locking system for fixing MCB’s / isolators including taking down existing old unserviceable MCB DB complete all as specified and as directed. |
| 101 | S&F MCB TPN 40 to 100 amps 240 volts \"C\" curve suitable for fixing in MCB DBincluding taking down existing old unserviceable MCB complete all as specified and as directed. |
| 102 | S&F MCB SPN 40 to 63 amps 240 volts \"C\" curve suitable for fixing in MCB DBincluding taking down existing old unserviceable MCB complete all as specified and as directed. |
| 103 | S&FMCB SP 6 to 32 amps 240 volts\"C\" curve suitable for fixing in MCB DBincluding taking down existing old unserviceable MCB complete all as specified and as directed. |
| 104 | M&L Sub main wiring with two runs of single core FRLS PVC multistranded stranded unsheathed copper conductor cable of size 2.5 square mm and drawing through PVC conduit of 20mm dia with accessories on surface in wall/roof along with one run of 2.5 square mm FRLS PVC insulated unsheathed multi stranded 1100 volts grade with copper conductor cable as earth continuity conductor connected to earth and earth dolly, connecting to main board including removing the existing wiring and making good the disturbed wall surfaces to match with the surroundingscomplete all as specified and directed.Note: 3 runs of 2.5 Sqmm cable and 1 run of PVC conduit with accessories shall be measured as 1 unit of running metre. |
| 105 | M&L Earthing with galvanized mild steel earth plate electrode 60 centimetre x 60 centimetre x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level connected to galvanized iron earth wire of 4 mm dia by means of bolts, nuts and washers made out of GI / steel earth wire protected by GI light grade pipe 15 mm bore, 20mm dia light grade galvanisediron pipe with funnel wire mesh for watering and connecting to main switch board / control board all s shown in electrical plateof SSR Pt - I connected to earthing test point and including testing on completion complete all as specified and as directed.Note: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 type C1 by using 20 mm graded aggregate inpit, 50 mm thick reinforced cement concrete 1:2:4 type B1 using 20 mm graded aggregate cover duly reinforced with 8 mm dia TMT bars @ 100mm centre to centre both ways,CI cover with CI frame hinges, galvanised iron funnel with watering pipe, wire mesh, complete. |
| 106 | M&L Sub main wiring with two runs of single core FRLS PVC multistranded stranded unsheathed copper conductor cable of size 6 square mm and drawing through PVC conduit of 20mm dia with accessories on surface in wall/roof along with one run of 6 square mm FRLS PVC insulated unsheathed multi stranded 1100 volts grade with copper conductor cable as earth continuity conductor connected to earth and earth dolly, connecting to main board including removing the existing wiring and making good the disturbed wall surfaces to match with the surroundingscomplete all as specified and directed.Note: 3 runs of 6 Sqmm cable and 1 run of PVC conduit with accessories shall be measured as 1 unit of running metre. |
| 107 | S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed /surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver threecore flexible copper conductor cases of suitable size complete all as specified and as directed. |
| 108 | S&F Sheet steel MS enclosure earth plug socket 2 pin 20 amps with metal 20 amps with MCB 20 amps complete all as specified and as directed. |
| 109 | M&L Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed by Engineer-in-Charge. |