Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SH: Demolition work of Existing Structures. |
| 2 | DISMANTLING & DEMOLISHING WORK |
| 3 | Taking out doors windows and clerestory windows shutters (wood or steel) including stacking within 50 m lead. |
| 4 | Not exceeding 3 sqm in area. |
| 5 | Dismantling steel work manually/ by mechanical means in built up sections without embering and stacking within 50 metres lead as per direction of Engineer-in-charge. |
| 6 | Extra for dismantling trusses, rafters, purlins etc. of steel work forevery additional span of one metre or part thereof beyond 10 metres metre span |
| 7 | Dismantling rooting including ridges, hips, valleys and gutters etc. and stacking the material within 50 metres lead of: |
| 8 | G.S. Sheet |
| 9 | Demolishing R.C.C work manually/ by mechanical means including stacking ot serviceable material and disposal ot unserviceable materialwithin 50 metros lead as per direction of Engineer-incharge. |
| 10 | Demolishing brick work manually/ by mechanical means including stacking ot serviceable material and disposal ot unserviceable materialwithin 50 metros lead as per direction of Engineer-incharge. |
| 11 | SH:- Land Development |
| 12 | EARTH WORKS: |
| 13 | Earthwork in rough excavation banking excavated earth in layer not exceeding 20 cm depth, breaking clods. Watering rolling each layer with 1/2 tonne roller or wodden or steel rammer & rolling every third and topmost layer with powerroller or minimum 8 tonne & dressing up embankment for roads flood banks guide banks marginal banks & filling up ground depressing Leadupto 50m and lift upto 1.5m in |
| 14 | All kind of soil |
| 15 | SH:Construction of Type VI (G+4 Quarters) with rooftop Gym Khana. |
| 16 | EARTH WORKS: |
| 17 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m. including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 18 | All Kinds of Soil |
| 19 | Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 20 | Supplying and filling in plinth with sandy soil under floors including watering, ramming, consolidating & dressing complete. |
| 21 | CEMENT CONCRETE WORKS: |
| 22 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level: |
| 23 | 1:2:4( 1cement:2 coarse sand:4 gradedstone aggregate 20mm nominal size) |
| 24 | 1:3:6( 1 Cement.• 3 coarse sand 6 graded stone aggregate 40 mm nominal size) |
| 25 | 1:4:8 (1 Cement:4 coarse sand:8 graded stone aggregate: 40 mm nominal size) |
| 26 | Providing & laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement: 2 coarsesand: 4 graded stone aggregate 20 mm nominal size) |
| 27 | Extra for providing and mixing water proofing material in cement concrete work @1kg per 50kg of cement |
| 28 | MISCELLANEOUS: |
| 29 | Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm bed of dry brick ballast 40 mm nominal size well rammed and consolidated and grouded with fine sand including finishing the top smooth. |
| 30 | R.C.C.WORKS: |
| 31 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level |
| 32 | 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 33 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 34 | 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 35 | R.C.C. work in beams, suspended floors, roofs having slope uptp 15o landings, balconies, shelves, chajjas,lintels, band, plain window sills, staircases and spiral staircases above plinth level upto floor fivelevel excluding the cost of centering, shuttering, finishing and reinforcement, with 1 : 1 .5: 3 (1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) |
| 36 | Providing and laying upto floor five level reinforced cement concrete In kerbs, steps and the like excluding the cost of centering, shuttering, finishing and reinforcement with(1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 37 | Providing, hoisting and fixing upto floor five lovol procast reinforced comont concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the tike including tho cost 01 required contoring, shuttering but excluding cost of reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand: 3graded stone aggregate 20mm nominal size). |
| 38 | Reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. |
| 39 | Thermo-Mechanically Treated bars |
| 40 | Reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete. Above Plinth Level. |
| 41 | Thermo-Mechanically Treated bars |
| 42 | FORM WORKS: |
| 43 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 44 | Foundations, footings, bases of columns, etc. for mass concrete |
| 45 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick |
| 46 | Suspended floors, roofs, andings, balconies and access platform with water proof ply 12 mm thick. |
| 47 | Columns, pillars, piers, abutments, posts and struts. |
| 48 | Stairs, (excluding landings) except spiral staircases. |
| 49 | Edges of slab and breaks in floor walls |
| 50 | Under 20 cm wide |
| 51 | Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards. |
| 52 | Walls (any thickness) including attached pilasters, buttresses plinth and string courses etc. |
| 53 | BRICK WORKS: |
| 54 | Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: |
| 55 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 56 | Half brick masonry 1st class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in |
| 57 | Cement mortar 1: 3 ( 1 cement: 3 coarse sand ) |
| 58 | Honey-comb brick work 10/11.4 cm thick with 1st class common burnt clay FP.S. (non modular) bricks in superstructure above plinth level and upto floor V level in cement mortar 1 : 4 ( 1 cement : 4 coarse sand) |
| 59 | Extra for half brick masonry in superstructure, above Floor V level for every four floors or part thereof by mechanical means by lifting materials using mobile crane |
| 60 | Brick edging 7cm wide 11.4 cm deep to plinth protection with 1st class common burnt clay F.P.S. (non modular) bricks i/c grouting with cement mortar 1:4(1 cement:4 fine sand). |
| 61 | WOOD WORKS |
| 62 | Providing wood works in frames of doors, windows, clerestory windows & other frames, wrought frameed & fixed in position with hold fast lugs or dash fastener shall be paid for separately: |
| 63 | Local best quality teakwood |
| 64 | Providnig and fixing panelled or panalled and glazed shutters for foors, windows and celestory windows including ISI marked M.S. butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all completely asd per direction of Engineer-in-charge. |
| 65 | Local best quality teakwood |
| 66 | 35mm thick shutters |
| 67 | Providing & fixing M.S. Grills of required pattern in frames of windows etc. With M.S. Flats, square or round bars etc. Including priming coat with approved steel primers all complete. |
| 68 | Fixed to openings /wooden frames with rawl plugs screws etc. |
| 69 | Providing & fixing 25 mm thickshutters for cup-board etc. i/c ISI marked black enamelled M.S. butthinges with necessary screws. |
| 70 | Panelled or panelled and Glazed shutters |
| 71 | Ist Class Teak |
| 72 | Providing & fixing bright finished bars 100 mm door mortice latch with one dead bolt & a pair of levers handles with necessary screws etc. complete (Best make of approved quality) |
| 73 | Providing and fixing bright finished brass door latch with necessary screws etc. complete : |
| 74 | 300x16x5mm |
| 75 | Providing & fixing bright finished brass Tower bolts (barrel type) with necessary screws etc. complete. |
| 76 | 250x10 mm |
| 77 | Providing and fixing chromium plated brass handles with necessary screws etc. complete: |
| 78 | 125 mm |
| 79 | STEEL WORKS |
| 80 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 81 | Electric resistance or induction butt welded tubes |
| 82 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required.. |
| 83 | In grating, frames, guard bar, railing, brackets, gates and similar works. |
| 84 | Providing and fixing stainless steel ( Grade 304) railing made ofHollow tubes, channels, plates etc., including welding, grinding, buffinge polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 85 | FLOORING: |
| 86 | Cement concrete flooring 1:2:4 (I cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost Of nosing of steps etc. complete. |
| 87 | 40mm thick with 20mm nominal size stone aggregate. |
| 88 | Cement plaster skirting (upto 30cm height) with cement mortar 1:3 (1 cement:3 coarse sand) finished with a floating coat of neat cement. |
| 89 | 18 mm thick |
| 90 | Providing and laying Vitrified tiles in floor in diffe rent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.080/0 and conforming to 19.15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will bo done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 91 | Double charge vitrified tile polished finish of size - Size of Tile 600 x 600 mm |
| 92 | Providing and fixing 1st quality ceramic glazed wall tiles conformingto IS : 15622 (thickness to be specified by the manufacture of approved make in alt colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (I cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 93 | Marble stone flooring with 18mm thick marble stone (sample Of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with |
| 94 | Makrana White second quality |
| 95 | Tile work in skirting, risers of steps and dado (upto 2 m height) over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shadecomplete |
| 96 | Marble tiles(polished) Raj Nagar |
| 97 | 8 mm thick |
| 98 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (I cement: 4 coarse sand): |
| 99 | 25 mm thick. |
| 100 | ROOFING AND CEILING: |
| 101 | Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of25x25xO.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.l. channels 45x15xO.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to Gil. intermediate channel with connecting clips made out of 2.64mm diax230mm long C.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/pattition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng to a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed. all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with |
| 102 | 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095 - Part 1 |
| 103 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineerin-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using selt drilling Iself tapping screws ot size (5.5x 55 mm) with EPDM seal,comptete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with |
| 104 | Precoated galvanised iron profile sheets 0.50 mm thick |
| 105 | Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or C.I. seam bolts and nuts, G.l. plain and bitumen washers complete |
| 106 | Ridges plain (500 - 600mm). |
| 107 | ALUMINIUM WINDOWS |
| 108 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required EPDM rubber/ Neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleatangle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steelscrews, all complete as per architectural drawings and the directions Of Engineer-incharge. (Glazing and panelling to be paid for separately): |
| 109 | For fixed portion. |
| 110 | Anodised aluminium (anodised transparent or dyed to required kg940.50 shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 111 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). |
| 112 | Anodised aluminium (anodised transparent or dyed to required kg Rss 1.03280 shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 113 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 114 | With float glass panes of 5.50 mm thickness |
| 115 | FINISHING: |
| 116 | 6 mm cement plaster of mix |
| 117 | 1:3(1 Cement:3 fine sand) |
| 118 | 12 mm cement plaster of mix 1:4 (1 cement:4 coarse sand). |
| 119 | (1 cement:4 coarse sand) |
| 120 | 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement:4 coarse sand). |
| 121 | 1:4 (1 cement:4 coarse sand). |
| 122 | Neat cement punning |
| 123 | 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall. |
| 124 | Applying one coat of cement primer of approved quality on wall surface : |
| 125 | Water thinnable cement primer |
| 126 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. |
| 127 | New work(two or more coats)over and including priming coat with cement primer |
| 128 | Finishing walls with textured exterior paint of required shade: |
| 129 | New Work(two or more coats applied @3.28ltr/10 Sqm)over and including base coat of water proofing cement paint [email protected]/10 sqm. |
| 130 | Applying one coat of water thinnable cement primer of approved brand and manufacture onq/all surface |
| 131 | Water thinnable cement primer |
| 132 | Applying priming coat:- |
| 133 | With ready mix pink or grey primer of approved brand and manufacture on wood work(hard and soft wood) |
| 134 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:- |
| 135 | Painting Steel work with Deluxe Multi Surface Paint to give an evenshade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 136 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth |
| 137 | Painting (two or more coats) with synthetic enamel paint of approved brand and manufacture to give an even shade. |
| 138 | Two or more coats on new work |
| 139 | Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tubewell boring machine shall not be used. |
| 140 | 450 mm dia piles |
| 141 | 600 mm diameter piles |
| 142 | Punched tape concertina coil 600 mm dia 10 m openable length |
| 143 | MISCELLANEOUS |
| 144 | Design,Installation,testing and commissioning of SS 10 Passenger Lift(680 KGS) Machine. |
| 145 | Design & Installation of Modular kitchen ,Cupboard for bedroom & TV units etc |
| 146 | SANITARY INSTALLATION |
| 147 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap. 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handlo lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 148 | White Vitreous china Orissa pattern W.C. pan of size 580 x 440 each as. 5,421.50 mm with integral type foot rests |
| 149 | Providing and fixing white vitreous china pedestal for wash basin eaccompletely recessed at the back for the reception of pipes and fittings |
| 150 | Providing and fixing P.V.C. tor sink or wash basin including P.V.C. waste fittings complete. |
| 151 | Flexible pipe |
| 152 | 32 mm dia |
| 153 | Providing and fixing 600x450 mm bovolod cdgo mirror of superior 1,053.30 glass (Of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass scrows and washers complete. |
| 154 | Providing and fixing PTMT liquid soap container 109 mm wide, 125each 195.80 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms |
| 155 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 156 | Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fitting with solvent cement, tenching, refilling & testing of joints complete as per direction of Engineer in charge |
| 157 | 75 mm dia |
| 158 | 110 mm dia |
| 159 | Water Supply |
| 160 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work. including cutting chases and making good the wall etc. |
| 161 | 20 mm diameter |
| 162 | 25 mm diameter |
| 163 | Providing and fixing G.l. pipes complete with G.l. fittings including trenching and refilling etc. External work |
| 164 | 32 mm diameter |
| 165 | 80 mm diameter |
| 166 | Supplying and fixing CI Cover with frame for manholes |
| 167 | 455x610 mm rectangular CI cover (light duty ) the weight of the cover to be not less than 25 kg |
| 168 | 17.29 Providing and fixing C.P. brass bib cock of approved quality conforming tQ IS:8931 |
| 169 | 15 mm diameter |
| 170 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make confcrming to 19.8931. |
| 171 | 15 mm diameter |
| 172 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 173 | 25 mm diameter |
| 174 | Providing and fixing gun metal non-return valve of approved quality (screwed end) |
| 175 | 32 mm diameter |
| 176 | horizontal |
| 177 | ProvidingandfixingC.P.brassshowerrosewith15mmor20mm |
| 178 | 100 mm diameter |
| 179 | Providing and placing on tcrrace (at all floor levels) polyethylene per litre 10.20 water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and tho baso support for tank. |
| 180 | (SH:Providing ofInternal Electrification installation ) |
| 181 | SUB HEAD-1: COPPER WIRING IN STEEL CONDUIT |
| 182 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 183 | Group A |
| 184 | Group B |
| 185 | Group C |
| 186 | Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 187 | Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 2 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 188 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 189 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 190 | 2X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 191 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 192 | Supply and drawing following size of steel conduit along with accessories in surface/ recess i/c painting in case of surface conduit or cuutt the wall and making good the same in case of recessed conduit as reqd |
| 193 | 25 mm |
| 194 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 195 | 5/6 A switch |
| 196 | 15/16 A switch |
| 197 | 3 pin 5/6 A socket outlet |
| 198 | 6 pin 15/16 A socket outlet |
| 199 | S/F 25 amp Air-Conditioner power plug point i/c 4 modules metal box on surface or in recess 4-modules plate and cover in front, 25 amp modular starter 25 amp modular socket outlet and 25 amp plug plate etc/ as reqd |
| 200 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 201 | Supply and fixing modular type blanking plate on existing modular plate and switch ox excluding modular plate as reqd. |
| 202 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.. |
| 203 | 1 or 2 Module (75 mmX75 mm) |
| 204 | 4 Module (125mm X 75mm) |
| 205 | 12 Module (200 mmX150 mm) |
| 206 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/wooden block includingonnectiontc as reqd. |
| 207 | SUB HEAD-II : MCCB, MCB & DB’S |
| 208 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders inexisting cubicle panel board including drilling holes in cubicle panel making connections etc as reqd. |
| 209 | 800 A , 35 KA, 4 Pole MCCB |
| 210 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 211 | 8 way, Double door |
| 212 | 12 way double door |
| 213 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 214 | Single pole |
| 215 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 216 | 43 amps |
| 217 | 63 amps |
| 218 | Supplying, installing, testing and commissioning of surfaceecess mounting vertical type 415V MB distribution board of sheet steel dust protected duly phosphatized and powder painted inclusive of 2 amps tinned copper busbar common neutral link earth bar din bar forunting MCB\"s detachable gland/knock out plate and with 100 amps 10A MCCB as incomer interconnection between incomer MCCB and bus of followingay (butthout MCB\"s) as reqd. |
| 219 | 12 Way (8+36) TPN MCB DB Duble door. |
| 220 | Earthing with copper plate 600mm x 600mm x 6mm thick i/c accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) as reqd |
| 221 | Extra for using salt and charcoal for G.I or copper plate earth electrode as reqd |
| 222 | SUB HEAD IV:- Fittings/Fixtures |
| 223 | S/F 48\"\" sweep (1200mm) A.C.Ceiling fan complete with down rod canopy 3 (three) blades but without regulator etc as reqd.(Make Bajaj/Usha or similar) |
| 224 | S/F 2 tone capacity split type Air conditioner, (Diamond, 3 Star, 5G 30, G-SC 24 FD 3 WJH) complete with Indo voltage stabilizer, Automatic 5KVA (140-280 for 2 ton) |
| 225 | Supplying, Erection, testing and commissioning of (pre-wired) wall bracket/ceiling fittings of all sizes and shapes containingCFL/LED/W GLS lamps per fitting, complete with all accessories including connection etc. as required(havell,s /Bajaja/Phillips/Cromton). |
| 226 | Ceiling fitting (Surface) with 15/18 watt LED Lamp. |
| 227 | S/F surface Pendent mounting 18 W led Downlight complete with driver i/c connections etc as reqd |
| 228 | Supplying, installtion of exhaust fan in the existing opening, including making good the damage, connection,testing,commissioning etc as reqd. |
| 229 | 225mm sweep |
| 230 | S/F surface Pendent mounting 9 W led bulb complete with driver i/c connections etc as reqd |
| 231 | Supplying V Cable at site as per specification of enineer in charge. |
| 232 | 16 mm (Two core) MV Cable |
| 233 | Lightning Conductor along with copper wire withall accessories |
| 234 | Telephone conduit includes point ,wiring and accessories etc. |
| 235 | (SH:Providing ofFire Fighting System ) |
| 236 | Providing & Fixing of M.S. pipeincluding of primer & red paint , fashner, MS bend , tei rod, universal clamp, MS socket,MS flange nut bolt , Gasket etc. Make : Nizone |
| 237 | 150 mm dia |
| 238 | 100 mm dia |
| 239 | 80 mm dia |
| 240 | 50 mm dia |
| 241 | 25 mm dia |
| 242 | Supply and fixingHydrant valve |
| 243 | Supply and fixing RRL hose pipe 15 mtr. Long including male female coupling |
| 244 | Supply and fixing Branch pipe |
| 245 | Supply and fixing Hose box |
| 246 | Supply and fixing Hose reel hose with drum 30 mtr long |
| 247 | Supply and fixing Two way Valve |
| 248 | Supply and fixing ABC type fire extinguisher 4 kg |
| 249 | Supply and fixing CO2 type fire extinguisher 4.5 kg |
| 250 | Supply and fixing Pendent type Sprinkler |
| 251 | Supply and fixing 25 mm ball valve including of fittings |
| 252 | Supply and fixing Butterfly Valve 100 mm dia |
| 253 | Supply and fixing Butterfly Valve 50 mm dia |
| 254 | Supply and fixing Non Return Valve 100 mm dia |
| 255 | Supply and fixing Foot Valve 100 mm dia |
| 256 | Supply and fixing Foot Valve 80 mm dia |
| 257 | Supply and fixing of Pressure Switch |
| 258 | Supply and fixing Pressure Gauge |
| 259 | Providingfixing of 5 HP Electrical mainpump incuding of all fittings (monoblock type) |
| 260 | Providing & fixing of Electric panel/starter for main pump |
| 261 | Providingfixing of 1620 LPM Fire Hydrantpump incuding of all fittings (monoblock type) |
| 262 | Supply, installation, testing and commissioning of 1 loop, compatable, microprocessor based intelligent Analogue Addressable Fire Alarm Control & Indication Panel, expandable to two loop, each loop can be capable of hauling minimum 99 addressable detectors and 99 addressable devices with 24 V SMF battery backup, charger circuit and 80 character LCD display module etc |
| 263 | Supply,Installation, testing and commissioning of Analogue Addressable Photo Electric Smoke Detector with mounting base, having protocol compatibility with Item No. (1) |
| 264 | Supply, installation, testing and commissioning of Analogue Addressable manual Call point, having protocol compatibility with Item No.1 |
| 265 | Supply, installation, testing and commissioning of Analogue Addressable Fire Alarm sounder cum strobe, having protocol compatibility with Item No.1 |
| 266 | Supply, installation, testing and commissioning of Short circuit fault isolator Module, having protocol compatibility with Item No.(36) |
| 267 | Supply and drawing of 2Cx1.5 sqm & shielded tinned copper wire |
| 268 | Supply and laying of 25mm MS Conduit with accessories |
| 269 | 1.5sq mm coper cable with PVC conduit |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy