| 1 | PART \"A\" CIVIL BUILDING WORK |
| 2 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 3 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar. |
| 4 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. |
| 5 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Walls (any thickness) including attached pilasters,buttressesplinthandstring course. |
| 6 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. |
| 7 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Columns, pillars, posts and struts etc. |
| 8 | Add extra for centering and shuttering work in superstructure above floor five level for each four floor or part thereof . |
| 9 | Add extra for additional height in centring, shutteringwhere ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at alllevels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan are is to be measured) |
| 10 | Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Design Mix |
| 11 | Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix |
| 12 | Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix |
| 13 | Providing and laying in position Ready mix concrete manufactured in fullyautomatic Batching Plant andtransported to site intransit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge.All works upto floor V floor M20 grade Design Mix by using cementas per codal provision. |
| 14 | Add extra for RCC work in superstructure above floor five level for each four floor or part there of |
| 15 | Add extra for providing richer mixes respectively at all floor levels Providing M-25 grade concrete by usingcement as per codal provision instead ofM-20 grade design mix. |
| 16 | Add extra for providing richer mixes respectively at all floor levels Providing M-30 grade concrete by usingcement as per codal provision instead ofM-20 grade design mix. |
| 17 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 18 | Add extra for reinforcementin superstructure above floor five level for each four flooror part thereof . |
| 19 | Providing & Laying autoclave aerated blocks masonry with 150mm/230mm/300mmthick AAC Blocks of Grade-I Conforming to IS:2185 Part:III in superstructureabove plinth levelwith polymer modified adhesive mortar as per direction of Engineer in Charge. |
| 20 | Add extra for AAC block masonary work in superstructure above floor five level, for each four floors or part thereof. |
| 21 | Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level upto floor V level in.Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 22 | Add extra for Square or Rectangular Pillars in Superstructre brick work up to five storey Upto 45 cm length and all sides are free |
| 23 | Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level upto floor V level in.Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 24 | Add extra providingand placing in position 2 Nos. ,6mm Ø M.S. barat every thirdcourse of half brick masonry . |
| 25 | Add extra for brick work in superstructure above floor five level, for each four floors or part thereof. |
| 26 | Quantity in Cum |
| 27 | Quantity in Sqm |
| 28 | Providing and fixing Marble stone flooring table rubbed, 15-18 mm thick over 20mm (Av.) thick base of CM 1:4 (1 cement : 4 coarse sand) jointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.ORProviding and fixing stone slabs table rubbed, 15-18 mm thick in Walls, Steps, Pillars, Counters, Jambs, Shelves, Sills etc. laid on 12mm (Av.) thick base of CM 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Rajnagar 1st quality/Ageria with light spots.1501 Cm2 to 3600 Cm2 Tiles |
| 29 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. |
| 30 | Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour)Above 3601 Cm2 Slabs |
| 31 | GRANITE |
| 32 | South Zed BlackAbove 3601 Cm2 Slabs |
| 33 | Extra for providing edge moulding to 15-18mm thick marble/ Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite/Kota Stone Work |
| 34 | Full Edge moulding |
| 35 | Half Edge moulding |
| 36 | P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. |
| 37 | size 800mmX800mm |
| 38 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). |
| 39 | Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). |
| 40 | ExtraforusingMarbleprinted/Graniteshadeordarkshadetilesinsteadofwhite,grey,ivory,fumeredbrown,lightgreen,lightblueandotherlightshadesinglazedtilesandMATfinishedtiles. |
| 41 | Extraforusingsize above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. |
| 42 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure \"A\":Commercial Veneer both side: 35 mm thick shutter |
| 43 | Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) |
| 44 | Providing & Fixing mica of approved make for inner/outer side of shutters with fevicol & nails completeas per approved by engineer in charge.0.8mm thick mica |
| 45 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide |
| 46 | Extra if square,rectangular hollow tubelarsections are used or grill made by flats only |
| 47 | Extra for hoisting and fixing for every additional one metre or part thereof beyond 10 mtr height. |
| 48 | Providing and installation of Poly Carbonate Sheet roofing over existing steel framing as per drawing and design including fixing with non-corrodible nuts and water proof washers as per instruction of Engineer-in-charge |
| 49 | Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish :12mm thick . |
| 50 | Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish :20 mm thick . |
| 51 | 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) |
| 52 | Making grooves as per design in plaster 10mm to 20mm wide. |
| 53 | Providing and Fixing Chiken wire mesh at the joint of masonry members/ R.C.C. Memberswith Nails complete in all respect. |
| 54 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth completeNew Plastered Surface (three or more coats) |
| 55 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. |
| 56 | Painting with synthetic enamel paint of approved brand and manufacture togive an even shade :Two or more coats on new work |
| 57 | Painting exterior surface ofWallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect including scaffolding and safety provision |
| 58 | Providing and fixing to existing door frames. 30mm thick factory made solid both side Pre laminated panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles and 15x15mmtop & bottom rails. M.S .frame shall have a coat of steel primers of approved make and manufacture M.S. frame covered with 5mm thick heat moulded PVC ‘C channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on either side forming stiles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75 mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2) thick, 20mm wide cross PVC sheet shall be provided as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with 7mm (5mm +2mm) thick x 15mm wide PVC sheet bending on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacture’s specification & drawing.(For W.C.and bathroom door shutter). |
| 59 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.(FOR HEIGHT 19 TO 22 METER) |
| 60 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.(FOR HEIGHT 22 TO 25 METER) |
| 61 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.(FOR HEIGHT 25 TO 28 METER) |
| 62 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.(FOR HEIGHT 28 TO 31 METER) |
| 63 | Providing and laying M30 grade controlled cement concretepavements including mixing and vibrations concrete with necessary needle vibrators and surface with screed board vibrating complete in all respect with 20/25 mm stone aggregate (crusher broken) including anti-skid textured finish to required camber/ super lavation and grade including curing etc. as per specification with cement concrete M-30 grade including cost of Steel frame work for sides of C.C. pavement consisting of M. S. channels flats and angles with required steel pegs ( some of them may left embedded in concrete/ including providing frame work |
| 64 | Extrafor vacuum processed concrete including cost of equipments labour etc. |
| 65 | Cutting of construction joint/ longitudinal joint 4 to 6 mm. wideusing mechanical concrete cutter including cost of diamond bit cutting wheel and filling of bitumen sealingcompound in groove including cost of sealing compound.50 mm depth |
| 66 | Sanitary work |
| 67 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 mspacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) |
| 68 | 20 mm nominal outer dia pipes |
| 69 | 25 mm nominal outer dia pipes |
| 70 | Providing and Fixing Unplastricized Poly Viny Chloride (UPVC) SWR Pipe Type B for sciland waste discharge system (IS 13592 : 1992 Marked ) of approved quality / make. 110mm dia |
| 71 | PVC Pipe 75 mm dia |
| 72 | PVC Pipe 110 mm dia |
| 73 | Providing and Fixing Unplastricized Poly Viny Chloride (UPVC) SWR Pipe fitting Type B for sciland waste discharge system (IS 13592 : 1992 Marked ) of approved quality / make. 110mm dia |
| 74 | Single tee with door 110mm |
| 75 | Bend 87.5 110mm |
| 76 | Door Bend 87.5 Dg. 110mm |
| 77 | Single tee 75mm |
| 78 | Nahani trap with Jali 110mm |
| 79 | Vent Cowel 110mm |
| 80 | Single \"Y\", 110mm |
| 81 | Single \"Y\" with Door 110mm |
| 82 | Double \"Y\" with Door,110mm |
| 83 | Concealed stop cock 15 mm nominal size |
| 84 | Making of holein R.C.C. slab/wall/beams and masonary wall (width up to 450 mm) by core cutting machine complete as per direction of EIFrom diameter 100mm to 150mm |
| 85 | Electrical works |
| 86 | Supply and fixing following size of Hot dipped Galvanized (275 GSM) floor raceways / Under floor trunking with/ without partion, including common cover, joint sleeve, cross over junction Box etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR |
| 87 | 100 mm x 25 mm x 1.5 mm |
| 88 | 150 mm x 25 mm x 1.5 mm |
| 89 | 150 mm x 38 mm x 1.5 mm |
| 90 | 250 mm x 38 mm x 2.0 mm with 3 Compartment |
| 91 | Supply and fixing following Hot dipped Galvanized (275 GSM) accessories for floor raceways / Under floor trunking etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work ,refer Annexure \"A\" attached with this BSR |
| 92 | Access Outlet 200 mm x 200 mm x 40-75 mm with Galvanized Lid |
| 93 | Access Outlet 300 mm x 300 mm x 40-75 mm with Galvanized Lid |