| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 14-05-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 21-05-2025 |
| Sl. No. | Item Description |
| 1 | Disconnecting, dismantlingof air cooled Packaged type AC Plant 16.5 TR capacity complete with indoor and out door unit,strip opening, cleaning & descaling complete withdust cleaning equipment and servicing of the AC plant with usingcaustic soda/detergent powder solution, taking out and removing unserviceable/defective minor parts & wiring ,painting the bottom with one coat of black synthetic enameled paint of out-door unit, replacement ofair filters, belt and replacement of the unserviceable and defective minor parts, heater,brazing,reassembling and testing of the AC plantcomplete all as specified and directed.NOTE :-(i) The defective/nonfunctional minor parts will be replaced by the contractor under the unit rate quoted for this item.(ii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A\".However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item. |
| 2 | Supply of lubricating oil anti freezing for refrigeration in factory sealed container of standardcapacityfor filling under Sch ‘A’items No 1 complete,all as specified and directed. Make: Servo froze -68-10c of IOC. |
| 3 | Supply fixing and testing in replacement of UNSVliqude line filtter driers of suitable sizefor Package type AC plant 16.5TR complete all as specified & directed. |
| 4 | Supply and fixing/testing in replacement of UNSVV belt \"A\" type as per existing for blower fan of packege type unit complete, all as specified and directed. |
| 5 | Supply and fixing/testing in replacement of UNSVcompressore5.5 tr makedenfoss/copland scrollcompressore R-407 with pressure testing complete, all as specified and directed. |
| 6 | Disconnecting & taking out existing defective blower motor Package type AC Plant of any description & in any position of size 2/3 HP, 415 volts strip opening for rewinding, removing for rewinding to & from to workshop, rewinding with appropriate size copper super enameled wire (Make : Atlas /Finolex /Devi Dayal )including suitable bearing, insulating material such as illuminous paper, Leatherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation & fixing the motor at siteincluding necessary connecting & testing at site complete all as specified anddirected. |
| 7 | Supply and fixing/testing in replacement of UNSV blower motor Package type AC Plant of any description & in any position of size 2/3 HP, 415 volts suitable for package type plant 16.5 TR |
| 8 | M&L for replacement of unserviceable remote control assembly with PCB plate complete with connections suitable for Package type AC 16.5 TR threephase capacity complete all as specified and directed .(Make : Carrier/Hitachi/LG ) |
| 9 | M&L for replacement of unserviceable condensing coil unit for Packagetype AC of any type/ any capacity complete, all as specified and directed.(Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH ) |
| 10 | Supply, fixing, connecting and testing in replacement of UNSVthermostate heating/cooling of any description complete,all as specified and directed. |
| 11 | Supply, fixing, connecting and testing in replacement of UNSV strip heater fins type, 3.0 KW, 230 volts, single phase, AC supply in any positioncomplete, all as specified and directed. |
| 12 | Supply fixing and testing in replacement of UNSV Pre filter with GI sheet frame of size 1000mm x 500mm x 8mm deep suitable for Pakage type units of air conditioning plantsincluding efficiency90% , down to 10-20microns, Initial Pressure drop- 2.5 mm WG, filter media shall be Synthetic Non Woven with Both Side HDPE Mesh, and t testing complete complete, all as specified and directed. |
| 13 | Dismantling & opening of GI sheet ducting from AHU for cleaning & descaling complete with air compressor, vacuum cleaning unit, dustcleaning equipment. The cleaning of duct to be started from AHU to different brances in different room.All the grills and diffusers are to be cleaned befor re-fixing. The rate shall also include cost of dismantling of false ceiling and its refixing, repair leakage ducts and refixing of ducts after complete cleaning process and testing etc. complete all as specified and directed. Note :- (i)Old disturbed insulation / leackage of ducts shall be made good by the contractor. |
| 14 | Supply fixing,connectingand testing in replacement of UNSV3 pole Power contactor with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC 3 rating 16Amps. Complete all as specified and directed .Make L&T or equievelent model of specified and directed. |
| 15 | Supply fixing and testing in replacement of UNSV 3 pole Power contactor with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC3 rating 50Amps. Complete all as specified and directed .Make L&T or equievelent model of specified and directed. |
| 16 | Supply fixing and testing in replacement of UNSV 3 pole Power contactor with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC3 rating 70Amps. Complete all as specified and directed .Make L&T or equievelent model of specified & directed |
| 17 | Supply fixing and testing in replacement of UNSVdigital type of size 96mm x 96mm, AC Volt meter 0- 500 Volts including wiring with 1.5 Sqmm PVC insulated stranded copper conductor cable complete all as specified and directed. |
| 18 | Supply fixing and testing in replacement of UNSVdigital type of size 96mm x 96mm, AC Amp meter 0- 200 Amps with including 3 Nos C.T of Ratio 200/5 of class-1.0 including wiring with 1.5 Sqmm PVC insulated stranded copper conductor cable complete all as specified and directed. |
| 19 | Supply fixing and testing in replacement of UNSVindicator light red/yellow /green complete in the existing panel Complete connecting electrically all as specified and directed |
| 20 | Supply, fixing, connecting and testing in replacement of UNSV MCB fourpole, 100 Amps 415 volts, 50 Hz having breaking capacity 10 KA , with adjustable thermal and fixed magnetic setting fixed in existing panel Complete all as specified and directed. Make : L&T /INDO ASIAN/Havells |
| 21 | Supply, fixing, connecting and testing in replacement of UNSVMCCB four pole, 100 Amps 415 volts, 50 Hz having breaking capacity 25 KA , with adjustable thermal and fixed magnetic setting fixed in existing panel Complete, all as specified and directed. Make : L&T /INDO ASIAN/Havells |
| 22 | Disconnecting, dismantling and taking out the non-functional Air conditioner window type of any description, any make and in any position, 1.5 TR/2 TR capacity, single phase, 50 Hz, strip opening, cleaning and servicing of the AC with usingcaustic soda/detergent powder solution, checking serviceability of wiring & parts,painting the bottom with one coat of black synthetic enameled paint,brazing, reassembling and testing of the ACcomplete, all as specified and directed. |
| 23 | Disconnecting, dismantling and taking out the existing Air conditioner Split type of any description, any make and in any position 1.5 TR/2 TR capacity,both indoor and outdoor unit single phase, strip opening , cleaning and servicing of the AC with using caustic soda/detergent solution, cleaning of suction air filter and coil of indoor unit and brazing the discharge and suction line, reassembling, fixing and testing of the AC complete, all as specified and directed.Note:(Applicable for Sch ‘A’ Item No.1& 2). (i) Window/Split type AC\"s shall be taken from department on \"as and where installed\" basis.(ii) Window/Split type AC\"s are to be maintained for heating as well cooling , where this provision is in the machine. (iii) The spare parts measured & paid separately as supply only rates. Rate for fixing of spare parts (ie compressor, condensing coil, cooling coil & blower motor) under relevant items shall be included in item No.1&2).(iv) The contractor shall ensure and asses at the site any initial maintenance required, to make the allWindow/Split type AC\"s in proper working condition, at the time of taking over and he shall be laible to make all listed handed over units functional.(ii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A\". However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item. |
| 24 | Supply only repaired compressor sealed unit of suitable capacity/ model in the unit properly for 1.5/2.0 TR window/Split type AC complete, all as specified and directed. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH ) |
| 25 | Supply only new Rotory type compressor sealed unit of suitable capasity/ model in the unit properly for 1.5 TR window/Split type AC complete, all as specified and directed. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH ) |
| 26 | Supply only new Rotory type compressor sealed unit of suitable capasity/ model in the unit properly for 2.0 TR window/Split type AC complete, all as specified and directed. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH ) |
| 27 | Supply only new condensing coil unit for window type AC of any type/ any capacity complete, all as specified and directed.(Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH ) |
| 28 | Supply only new condensing coil unit for Split type AC of any type/ any capacity complete, all as specified and directed.(Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH ) |
| 29 | Supply only blower motor including fan blade, capacitor complete suitable for Window type AC 1.5 ton/2.0 ton capacity 1/5 HP, 220 Volts, single phasecomplete, all as specified and directed. |
| 30 | Supply only blower motor including fan blade, capacitor complete suitable for split type AC 1.5 ton/2.0 ton capacity 1/8 HP, 220 Volts, single phasecomplete, all as specified and directed. |
| 31 | Supply only cooling coil unit for window type AC of any type/ any capacity complete, all as specified and directed. |
| 32 | M&L for charging refrigerant gas in the system of window/Split type AC of 1.5/2.0 ton capacity complete, all as specified and directed.(Note : The refrigerant gas measured and paid separately under relevant items as applicable as ‘supply only’). |
| 33 | M&L for replacement of unserviceable door Invertor type PCBsuitable for 1.5/2.0 TRsplit type AC complete, all as specified and directed.(Make:Blue Star / Alloyds ) |
| 34 | M&L for replacement of unserviceable running capacitor 36/45/50 MFD 230 V for window/Split type AC 1.5 Ton/2.0 Ton capacity complete, all as specified and directed. (Make : Universal/Sarda ) |
| 35 | M&L for replacement of unserviceableindoorInvertor type PCBsuitable for 1.5/2.0 TRsplit type AC complete, all as specified and directed.(Make : Blue Star / Alloyds ) |
| 36 | M&L for replacement of unserviceable Relay (1622) suitable for window/Split type AC 1.5 Ton/2.0 Ton capacity complete, all as specified and directed. |
| 37 | M&L for replacement of unserviceable thermostat suitable for window type Ac 1.5 ton/2.0 ton capacity complete, all as specified and directed.(Make : Indofoss or equivalent as approved). |
| 38 | M&L for replacement of unserviceable capillary tube and stainer for window/Split type AC of 1.5 ton/2.0 ton capacity complete, all as specified and directed . |
| 39 | M&L for replacement of unserviceable operation knob fro window type AC 1.5 ton/2.0 ton capacity complete, all as specified and directed . |
| 40 | M&L for replacement of unserviceable PVC air filter for window type AC of 1.5 ton/2.0 ton capacity complete, all as specified and directed . |
| 41 | M&L for replacement of unserviceable PVC air filter for Split type AC of 1.5 ton/2.0 ton capacity complete, all as specified and directed . |
| 42 | M&L for replacement of unserviceable capacitor for blower motor suitable for window /Split type AC 1.5 ton/2.0 ton capacity complete, all as specified and directed . |
| 43 | M&L for replacement of unserviceable fan blade for blower motor suitable for window /Split type AC 1.5 ton/2.0 ton capacity complete, all as specified and directed . |
| 44 | M&L for replacement of unserviceable swinging motor with louvers as per existing make for Split type AC 1.5 ton/2.0 ton capacity complete, all as specified and directed . |
| 45 | M&L for replacement of unserviceable remote control assembly with PCB plate complete with connections suitable for Split AC 1.5TR/2TR singlephase capacity complete all as specified and directed .(Make : Carrier/Hitachi/LG ) |
| 46 | M&L for replacement of unserviceable LCD / LED display unit for Window/split type AC 1.5 / 2.0 ton capacity complete, all as specified and directed . |
| 47 | M&L for replacement of unserviceable 15/20 mm bore PVC flexible conduit complete, all as specified and directed . |
| 48 | M&L for replacement unserviceable wiring for AC window type /split type1.5 ton/2.0 ton capacity and rewiring with suitable size multi stranded copper cable including testing, checking etc complete, all as specified and directed . |
| 49 | Supply and fixing in replacing refrigerant copper tubing5/8\" / 1/2\" / 3/8\" / 1/4\" dia (as per existing one) with 22 gauge , fixed on wall / ceiling with saddle as per site requirement including making joints by brazing / flairing and checking for any leakage complete, all as specified and directed . |
| 50 | Supply and fixing in replacment foam type insulation sleeve for copper tubing5/8\" / 1/2\" / 3/8\" / 1/4\" dia (as per existing one) binding and securing the insulation firmly with copper tubing as per site requirement complete, all as specified and directed . |
| 51 | M&L for replacement of unserviceable reverse cycle valve in window/Splittype AC of 1.5 / 2 TR cap. and welding, brazing with copper tubing and testing complete all as specified and directed. Make : Renutrol/Pacific |
| 52 | M&L for replacement of unserviceable PVC insulated PVC sheathed 1.5 Sqmm, 3 core copper cable 1100 Volts confirming to IS complete, all as specified and directed . (Make : KDK/Nicco/Finolex/Havells) |
| 53 | M&L for replacement of unserviceablePVC insulated PVC sheathed 2.5 Sqmm, 3 core copper cable 1100 Volts confirming to IS complete, all as specified and directed .(Make : KDK/Nicco/Finolex/Havells) |
| 54 | M&L for dismantling of storage type water cooler of 40/80/150 ltrs capacity of existing modelin various location, shifting to MES Yard for repair/replacement of unserviceable spares and painting the outer body (including replacement of corroded sheet with new one) by spraying enamel paint and sticking a stickermentioning the “No, Date of overhauling, Due date, CA No., Contractor’s name, user’s signature’ reassembling, testing, checking and shifted to existing location, fixing the same by nut, bolt, angle iron structure and masonry work all as directed & specified by Engineer-in-Charge. (NOTE: The spare parts ( ie compressor, blower motor) measured & paid separately as supply only rates.Rates for fixing of spares parts under the unit rate quoted by the contractor for this item. |
| 55 | Supply only new compressor sealed unit of 40/80 ltrs capacity of existing modelin the unit properly for storage type water cooler of any type complete, all as specified and directed .(Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH ) |
| 56 | Supply only new compressor sealed unit of 150 ltrs capacity of existing modelin the unit properly for storage type water cooler of any type complete,all as specified and directed . (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH ) |
| 57 | Supply only blower motor including fan blade, capacitor complete suitable for 40/80 ltrs capacity, 220 volts, single phase complete, all as specified and directed . |
| 58 | Supply only blower motor including fan blade, capacitor complete suitable for 150 ltrs capacity, 220 volts, single phase all as specified and directed . |
| 59 | Supply only new condensing coil unit suitable for 40/80 ltrs capacity, 220 volts, single phase complete, all as specified and directed . |
| 60 | Supply only new condensing coil unit suitable for 150 ltrs capacity, 220 volts, single phase complete, all as specified and directed . |
| 61 | M&L for charging refrigerant gas in the system of water cooler of any capacity complete, all as directed . (Note : The refrigerant gasmeasured and paid separately under relevant items as applicable as supply only). |
| 62 | M&L for replacement of unserviceable capillary tube and stainer for storage type water cooler of 40/60/150 ltrscapacity complete, all as specified and directed . |
| 63 | M&L for replacement of unserviceable overload protection coil 230 volts for water cooler of 40/60/150 ltrscapacity complete, all as specified and directed . |
| 64 | M&L for replacement of unserviceable relay suitable for water cooler of 40/60/150 ltrs capacity complete, all as specified and directed.(Make : Indfoss / Usha / Arvind) |
| 65 | M&L for replacement of unserviceable thermostat suitable for water cooler of 40/60/150 ltrscapacity icomplete, all as specified and directed . (Make : Indfoss/Asian). |
| 66 | M&L for replacement of unserviceable starting capacitor 80/100 MFD 230 Volts AC for water cooler of capacity 40/60/150 ltrs complete, all as specified and directed. (Make : Indfoss/Sarda ) |
| 67 | M&L for replacement of unserviceable running capacitor suitable for water cooler of capacity 40/60/150 ltrscomplete, all as specified and directed .(Make : Indfoss/Sarda). |
| 68 | M&L for replacement of unserviceable fan blade for water cooler of 40/60/150 ltrscapacity complete, all as specified and directed . |
| 69 | M&L for replacement of unserviceable capacitor for blower motor suitable for water cooler of 40/60/150 ltrscapacity complete, all as specified and directed . |
| 70 | M&L for replacement of unserviceable internal wiring of AC, water cooler, refrigerator of any capacity and rewiring the same with 2.5 Sqmm size multi stranded copper cable incl testing checking etc complete, all as specified and directed . |
| 71 | M&L for replacement of head cover gasket for water cooler of 40/60/150 ltrs capacity complete, all as specified and directed . |
| 72 | M&L for dismantling of storage type refrigerator/freezers of 165/212/310 ltrscapacity in various location, shifting it to MES yard for repair/replacement of unserviceable spares and painting the outer body (including replacement of corroded sheet with new one) by spraying enamel paintand eassembling, testing, checking and shifted to existing location including masonry work complete, all as specified and directed . (NOTE: The spare parts ( ie compressor, cooling unit ) measured and paid separately as supply only rate.Rates for fixing of spare parts under the unit rate quoted by the contractor for this item. |
| 73 | Supply only new compressor seal unit of 165/212 ltrs capacity of existingmodel in the unit properly for domestic refrigerator/freezers of any type all as specified and directed . |
| 74 | Supply only freezer coil unit for domestic refrigerator of any type/ any capacity complete, all as specified and directed. |
| 75 | M&L for charging refrigerant gas in the system of domestic refrigerator of any type/ any capacity complete, all as specified and directed .(Note : the refrigerant gasmeasured and paid separately under relevent items as applicable as supply only ). |
| 76 | M&L for replacement of unserviceable capillary tube and stainer for any type and capacity complete fordomestic refrigerator/freezer complete, all as specified and directed . |
| 77 | M&L for replacement of unserviceable timer/bimetallic relay of existing type for domestic refrigerator/freezer,complete, all as specified and directed . |
| 78 | M&L for replacement of unserviceable over load relay for domestic refrigerator/freezer of any type/ any capacity complete, all as specified ans directed . |
| 79 | M&L for replacement of unserviceable thermostat for domestic refrigerator/freezer of any type/any capacity complete, all as specified ans directed . |
| 80 | Supply only refrigerant gas R-22. |
| 81 | Supply only refrigerant gas 134A. |
| 82 | Supply only refrigerant gas R-407/R-410/R-32 (HYDRO CARBON) |
| 83 | M&L for replacement of angular valve of size 1/2\" suitable for split type AC complete, all as specified and directed . |
| 84 | M&L for replacement of angular valve of size ¼\" suitable for split type AC complete. all as specified & directed. |
| 85 | M&L for replacement of angular valve of size 5/8\" suitable for split type AC complete. all as specified & directed. |
| 86 | M&L for replacement of angular valve of size 3/8\" suitable for split type AC complete. all as specified & directed. |
| 87 | Supply only Remote control for split/ Window type AC of LG/Samsung/existingmake of 1.5 TR/2 TR with battery complete. all as specified & directed. |
| 88 | M & L for dismantling of unserviceable voltage stablizer of capacity 3 KVA/4 KVA/5 KVA in various location for repair/replacement of unserviceable parts, cleaning, servicing, checking, reassembling, testing and handed over to MES in serviceable condition all as specifiedanddirectedby Engr-in-Charge (Note :- The spare parts measured and paid separately as supply only rates. Rates for fixing of spare parts under relevant items shall be included in item) |
| 89 | Supply onlytransformer copper wound ofvoltage stabilizerAC, Single Phase, 230 volts of capacity 3/4/5 KVA of approved make complete all as specified and directed. |
| 90 | Supply only relay 12/24 volts suitable for 3/4/5 KVA voltage stabilizer AC, Single Phase, 230 volts of approved make complete all as specified and directed. |
| 91 | Supply only electromechanical type voltmeter 0 to 300 volts Single Phase , AC,65 mm square/round for stabilizer as per requirement complete all as specified & directed. Make – AE or equivalent approved. |
| 92 | Supply only DC electronic circuit for relay of capacity 24/12 volts stabilizer for3 to 5KVA of approved make complete all as specified & directed. |
| 93 | Supply only 3 way connector 230 volts 50 Hz AC, 32 Amp of approved make & existing shape and size complete all as specified and directed. |
| 94 | Supply only toggle switch 20/30 Amp two way of approved makecomplete all as specified and directed. |
| 95 | Installation only split type AC including indoor/outdoor unit of capacity 1.5 Ton/2 Tonafter carried out the repair under item No.2atnew location as directed including providing necessary chiseling/ cutting for fix the indoor/outdoor unitby means of suitable size of nut, bolt, angle iron structure, masonry work and making good the disturbed surface withPCC, plastering,white wash works,testing & checking complete,all as directed & specified by Engineer-in-Charge. (Note :- The spare parts measured & paid separately as supply only rates. Rate for fixing of spare parts (ie compressor, condensing coil, blower motor and nut bolt angle iron structure) under relevant items shall be included in this item) complete,all as specified & directed by Engineer-in-Charge. |
| 96 | Supply &Fixing in replacement of unserviceable Oudoor unitbody complete with out compressor unitsuitable for existing Split type AC of 1.5 TR capacity, complete,all as specified & directed by Engineer-in-Charge. |
| 97 | Supply &Fixing in replacement of unserviceableindoor unitbody complete suitable for existing Split type AC of 1.5 TR capacity, all as specified and directed . |
| 98 | M & L for preparation of the steel surfaces of desert cooler and applying one coat of synthetic enameled paint on all exterior surfaces and applying one coat of black bituminous paint on all interior surfaces including bottom surfaces and writing MES No of the desert cooler in the pattern as approved by the Engineer-in-Charge with different tint / colour complete all as specified and directed. |
| 99 | Supply &Fixing in replacement of unserviceablePVC distributor 3 way, suitable for 15mm dia water distribution complete all as specified and directed. |
| 100 | Supply &Fixing in replacement of unserviceable wood wool pads best quality of required size as approved (three in each on desert cooler) complete all as specified and directed. |
| 101 | Supply &Fixing in replacement of unserviceable Water circulating pump 1/ 70 H P capacity single phase 230 volts, 1340 RPM, 1.5 Mtr head suitable fot any make any capacity of Desert coolerMake : AUE / CG/ Kaithan complete,all as specified & directed. |
| 102 | Supply &Fixing in replacement of unserviceable plug top3 pin, 15/16 Amp capacity complete all as specified and directed.Make : Anchor (Penta deluxe) or equivalent as approved by GE. |
| 103 | Supply &Fixing in replacement of unserviceable Capacitor suitable for any type any capacity of desert cooler fan motor complete,all as specified & directed. |
| 104 | Supply &Fixing in replacement of unserviceable Regulator for any type any make of Desert cooler |
| 105 | Disconnecting and removing the water and electric connections carefully from the existing Geyser of capacity 25/50 ltrs, any makeand taking out the same in any position from the existing location.Opening the Geyser for inspection, repairs and reassembling the same as per the original assembly after repairs/ replaceing the wourn out unserviceable parts with new parts as orderedincludingre-fixing same position of the Geyser and making electric connection, water inlet and outlet connection, testing andchecking of all the functioning of water inlet outlet valves connected with geysers.all as specified and directed . Note :- Spare parts if any requires replacement shall be measured and paid for separately. |
| 106 | Disconnecting and taking down the existing Geyser of any description and any capacity (25 / 50 Ltrs) and any position from the existing location and Dismantling the Geyser of any capacity and of any description material and labour for cleaning and de-scaling the inner tank and other parts / accessories including inlet, outlet , overflowGeyser element, thermostat , base assembly etc. with brush, cleaning rod, and using de-scaling solution mixed with water in suitable proportion till the complete deposits /scale is removed as approved by Engineer-in-Charge, brazingfor stopping leakage of copper inner tank/gas welding for inner steel tank, re- assembling the complete Geyser after cleaning,Fixing and installation of Geyser in position and testing to the entire satisfaction of Engineer-in-Charge.Note :- Spare parts if any requires replacement shall be measured and paid for separately |
| 107 | Supply only Rubber PVC gasket to ensure water tightness for 25/50 liters capacity complete, all as specified and as directed . |
| 108 | Supply only MS base plate cup any type with screws of suitable size as per requirement complete, all as specified and as directed . |
| 109 | Supply only Heating element of the 1.5/2 KW rating as required at site including rubber washers of any make and type complete, all as specified and as directed by Engr-in-charge |
| 110 | Supply only Steelinner tank of 25 litre capacity geyser tank by made out of steel sheets appropriate thickness complete, all as specified and as directed . |
| 111 | Supply only Steelinner tank of 50 litre capacity geyser tank bymade out of steel sheets appropriate thickness complete, all as specified and as directed . |
| 112 | Supply only Insulating material (glass wool for Geyser) complete, all as specified and as directed . |
| 113 | Supply only Thermostatwith setting range 30°Cto80°Csuitable for230 volts AC, electric supply complete all as specified and directed, Make – Recold / Bajaj,/ Daspass |
| 114 | Supply only Base assay complete with inlet, out let and pipes with drain plug and screw for fixing the element inclusive of clamps for holding the element with nut, bolt and washers fsuitable for 25 Liters cap to 50 Liters cap complete, all as specified and as directed . |
| 115 | Supply only Non return valve 15 mm dia cast copper alloyISI mark complete, all as specified and as directed . |
| 116 | Supply only Safety valve/Fusible plug 15mm complete, all as specified and as directed . |
| 117 | Supply only Chromium plate copper connecting tube 450 mm long with two brass adopters suitable for 15 dia pipe and connecting up complete with washers complete, all as specified and as directed . |
| 118 | Supply onlyPVC connecting tube 450 mm long with two brass adopters suitable for 15 mm dia pipe and fixing in position ,superior quality complete, all as specified and as directed . |
| 119 | M&L in replacement of unserviceable bottom plate of geysers 25/50 liters capacity, same sizes and shape complete all as specified & directed. |
| 120 | M&L in replacement of unserviceable air release valve 15 mm bore for geyser as per existing typecomplete all as specified and directed. |
| 121 | M&L in replacement of unserviceable Indicating lamp of size /shape as per existing suitable for 230 Volts AC supply. complete all as specified and directed |
| 122 | M&L for Painting of geysers size 25/50 liter any make with two coats of broken white enameled paint with spray gun of approved quality after removing all dust/rust and scrapping up old painted surface including preparation, filling of cavaties with metal putty, complete including writing MES No in 2 mm width letter on geyser body with black enameled paint complete all as specified and directed. |
| 123 | Disconnecting , taking down & removing carefully the existingceiling fans etc. of any description, any sweep and from any position / locations (i.e. Md Accn/ OTM Accn/ Md Hostel/ Workshop/ Installations) for repairs / servicing / overhauling / painting / numbering etc., dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessaryadjustment and proper alignment of blades, hanging / fixing the repaired fans in position, connecting to existing electric sources and testing at site to the entire satisfaction of Engineer-in-Charge complete, all as specified and directed. |
| 124 | Disconnecting , taking down & removing carefully the existing exhaust fans etc. of any description, any sweep and from any position / locations (i.e. Md Accn/ OTM Accn/ Md Hostel/ Workshop/ Installations) for repairs / servicing / overhauling / painting / numbering etc., dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessaryadjustment and proper alignment of blades, hanging / fixing the repaired fans in position, connecting to existing electric sources and testing at site to the entire satisfaction of Engineer-in-Charge complete, all as specified and directed. |
| 125 | Disconnecting,taking down and removing carefully the existing table fan, Air circulator wall mounting fan,pedestalfan, of any description, any sweep and from any position / locations for repairs / servicing / overhauling / painting / numbering etc., dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessaryadjustment and proper alignment of blades, connecting the fans to existing electric sources and testing at site to the entire satisfaction complete, all as specified and directed. |
| 126 | Note for item 123 to item 125 here in before :(i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding.(iii)The rates for above items are deemed to include for transportation to & fro of fans to workshop if required and approved by the Engineer-in-charge for necessary repairs.(iv)Cost of minor repair i.e. loose connection tightening, oiling greasing, tightening nut- bolts, insulating wire etc deemed to be inclusive in the item rate above.(v) Writing of fan No. and painting of fans shall be measured and paid for separatelyunder appropriate item of Sch ‘A’ |
| 127 | Supply only the following new parts suitable for the ceiling/ exhaust fans, wall bracket fans & pedestal fans, air circulating fans etc. of any description, any sweep :- Note :- Fixing & testing charges of these items are deemed to be included in the rates quoted by the tenderer for Sch ‘A’ item No. 127 above |
| 128 | Supplying only ball bearing No 6200 (Make SKF/NRB/NBC) |
| 129 | Supplying only ball bearing No 6201 (Make SKF/NRB/NBC) |
| 130 | Supplying onlyball bearing No 6202 (Make SKF/NRB/NBC) |
| 131 | Supplying only ball bearing No 6203 (Make SKF/NRB/NBC) |
| 132 | Supply only gun metal bushes of any description and size to suit existing motor shaft. |
| 133 | Supplying only capacitor of capacity 2.5 mfd(PVC body) (Make:- EPCOS/JYOTI/ USHA) |
| 134 | Supplying only capacitor of capacity 4 mfd(PVC body) (Make:- EPCOS/JYOTI/USHA) |
| 135 | Supply only complete hanging assembly set comprising with rubber reel, MS clamps, nuts,bolts with lock pins suitable for any type of fans & down rods of length 300mm. |
| 136 | Supplying only aluminium cast metal fan blade assembly with necessary MS nuts, bolts & washers suitable for ceiling fans of any descriptions & of 1200/1400 mm sweep. Note: (i) Set of three blades shall be measured as one unit(ii) Make of the blade assembly shall be as approved by GE |
| 137 | Supplying only PVC fan blade assembly with necessary MS nuts, bolts & washers suitable for exhaust fans of any descriptions & of 230 mm sweep.(Note: Set of three blades shall be measured as one unit and make of assembly shall be as approved by GE.) |
| 138 | Supplying only aluminium cast metal fan blade assembly with necessary MS nuts, bolts & washers suitable for exhaust fans of any descriptions & of 300/450 mm sweep.(Note: Set of three blades shall be measured as one unit and make of assembly shall be as approved by GE.) |
| 139 | Supplying only aluminium cast metal fan blade assembly with necessary MS nuts, bolts & washers suitable for air circulator/wall mounting/table ans of any descriptions & of 400/610 mm sweep.(Note: Set of three blades shall be measured as one unit and make of assembly shall be as approved by GE.) |
| 140 | Supply only PVC insulated and sheathed, round flexible cable, three core of size 0.50 Sqmm with copper conductor in pieces for connecting fans. (Make :Havell’s / Finolex / Gloster / National/ Plaza ) |
| 141 | Supply only MS nuts & bolts with one hole washer & lock pin of suitable size for hanging assembly complete,all as specified & directed. |
| 142 | Supply only rubber reel bushof suitable size of hanging assemblycomplete,all as specified & directed. |
| 143 | Supply only MS tube medium grade 15mm dia duly finished with white colourtwo coats over a coat of red oxide cutting in desired length from 300mm to 1500mm, cutting slot and drilling hole for down rod of fan complete all as specifieda and directed. |
| 144 | Taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire (Make : Atlas/Finolex/Devi Dayal) as approved by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of Engineer-in-chargefor the following Fans:- |
| 145 | Rewinding of motor of ceiling fans 1200 mmsweep. |
| 146 | Rewinding of motor of ceiling fans 1400 mmsweep. |
| 147 | Rewinding of motor of exhaust fan of 230/300/450 mm sweep. |
| 148 | Rewinding of motor of wall mounted fan of 400 mm sweep. |
| 149 | Taking down existing worn out louversof any description , in any position and supplying & fixing new louvers made out of MS sheet 22 gaugethick suitable for exhaust fan of 230/300mm sweepcomplete,all as specified & directed.( Note: The louvers shall be of shape, size and pattern as approved by the Engineer-in-Charge duly painted with two coat of synthetic enamel paint over a coat of red oxide primer) |
| 150 | Taking down existing worn out louversof any description , in any position and supplying & fixing new louvers made out of MS sheet 22 gaugethick suitable for exhaust fan of 450mm sweepcomplete,all as specified & directed.( Note: The louvers shall be of shape, size and pattern as approved by the Engineer-in-Charge duly painted with two coat of synthetic enamel paint over a coat of red oxide primer) |
| 151 | Disconnecting & taking out old existing unserviceable ceiling fan regulator of any description & in any position / location and Supply and fixing ceiling fan regulator electronic, step type suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supplycomplete all as specified & directed.(Make :- Anchor/Cona/Leader) |
| 152 | Disconnecting and taking out old existing unserviceable ceiling fan modular regulator of any description and in any position/ location and supply and fixing ceiling fan modular regulator electronic, step type, 1M size modular type , suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supplycomplete all as specified and directed. (Make :- Anchor/Cona/Leader) |
| 153 | Disconnecting & taking out old existing unserviceable ceiling fan modular regulator of any description & in any position / location and Supply and fixing ceilingfan modular regulator electronic, step type, 2M size piano type, suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply 100Watt complete all as specified & directed.(Make :- Anchor/Cona/Leader) |
| 154 | M & L for painting of existing fans of any description of ceiling fan of 1200/1400mm sweepwith applying one coat of synthetic enamel paint (White) by spray machine including preparation of existing decorated surfaces of fans including numbering etc, complete,all as specified & directed. |
| 155 | M & L for painting of existing fans of any description of exhaust fan of 230/300/450mm sweep with applying one coat of synthetic enamel paint grey by spray machine including preparation of existing decorated surfaces of fans including numbering etc complete,all as specified & directed. |
| 156 | Supplying and fixing GI tubing 40mm, medium grade for hanging of ceiling fans including cutting holes in walls built in cement mortar and making good in cement sand mortar 1:4 and finish the surface to match with existing complete,all as specified & directed. |
| 157 | Taking down carefully existing points wiring on surface conduit/concealed conduit forlight/fan/socket/power/bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, pieces of wires, gutties, conduit, wooden boards etc and making good the disturbed portion of all floor, ceiling etc all as specified and directed. |
| 158 | M&L for point wiring with single corePVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI markednot less than 20mm dia, concealed conduit wiring in walls and surface with GI saddles GI screws, rawal plugs in ceiling or roof if not possibleincluding Tee, Junction boxes and provision offlush metal boxes, inner and outer plate suitable for modular switch, socket and fan regulator as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi strandedcopper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for one light/Fan point controlled by one Switch. |
| 159 | All as per Sl item No 158 above herein before but controlled by two 2 way switch complete all as specified and directed. |
| 160 | All as per Sl item No 158 above herein before but one socket out let 5 pins 5 Amp on the independent board complete all as specified and directed. |
| 161 | All as per Sl item No 158 above herein before but one socket out let 5 pins 5 Amp on the same board but with other switches complete all as specified and directed. |
| 162 | All as per item No.2 herein beforebut 2.5 Sqmm PVC insulated and unsheathed FRLS single core multistranded copper conductor incl 2.5 Sqmm PVC insulated and unsheathed FRLScopperearth wire for modular switch socket combination 3 pin 15 amps on independent board |
| 163 | S&F Modular Socket6A/16A - 2/3 pin combined 2 module suitablefor 15 Amp plug top Multipurpose 230 V complete,all as specified & directed. |
| 164 | S & F Modular Socket, 6A - 2/3 pin combined 2 module, 230 V complete,all as specified & directed. |
| 165 | S & F Modular Switch Piano flush type 6 amp single Pole one way 230 V complete,all as specified & directed. |
| 166 | S & F Modular Switch Piano flush type 6 amp single Pole two way 230 V complete,all as specified & directed. |
| 167 | S & F Modular switch 1 way 16A, 1 module flush type single Pole one way 230 V complete,all as specified & directed. |
| 168 | S & F Ceiling rose surface bakelite surface 65 x 50mm, 3 terminals complete,all as specified & directed. |
| 169 | S & F modular Switch Bell push 5 amp single Pole230 V complete,all as specified & directed. |
| 170 | S & F Bellding dong type, AC 230 volts complete,all as specified & directed. |
| 171 | S & F Lamp holder insulated body with back plate batten/angle type for batten fittings complete all as specified and directed. |
| 172 | S & F wall mounted decorative light with 9 W LED bulb complete all as specified and directed. |
| 173 | S & F LED bulb 7 W all as specfied and directed |
| 174 | S&F in replacement of UNSV bulkhead fitting with integrated LED bulk head fitting 10W 600 lumens, 6000 K comprises of pressure die cast housing, acrylic diffuser and frame IP 65 protection, IK-07 etcincluding connection complete all as specified and directed. Make- C&G or equivalent in Havells/Phillips as approved. |
| 175 | Supply & Fixing LED light fitting 10 W batten (Mirror light) for Retro LED Energy saving tube light , high efficiency PMMA diffuser gives soft glare free light environmental friendly, energy efficient ready to use pack complete,all as specified & directed. |
| 176 | Supply & Fixing LED light fitting 20 W batten for Retro LED Energy saving tube light, high efficiency PMMA diffuser gives soft glare free light environmental friendly, energy efficient ready to use pack complete,all as specified & directed. |
| 177 | Supply and fixing LED Bollard light IP65 Rated with robust design and efficient light distribution Crompton syrus Cat part No LBLSR-10-CDL all as specified and directed. |
| 178 | Supplying & fixing, testing in replacement UNSV of surface mounted in built , LED 18 watts, 1\"x1\" LED ceilinglight fitting with slim line extruded aluminium/ CRCA body, opel acrylic diffuser, electronic driver etc and all accessories pre-wired including connecting to source complete all as specified and directed. Make- Crompton cat pt No- LCTLSNE-18-FO-CDL or equivalent model of Havells / Philips as approved . |
| 179 | Supplying & fixing, testing in replacement UNSV of surface mounted in built , LED24watts, 2\"x2\" LED ceilinglight fitting with slim line extruded aluminium/ CRCA body, opel acrylic diffuser, electronic driver etc and all accessories pre-wired including connecting to source complete all as specified and directed. Make- Crompton cat pt No- LCTLSNE24-FO-CDL or equivalent model of Havells / Philips as approved . |
| 180 | S & F modular electronic ceiling fan regulator stepped type 2 module 120 W heavy duty suitable to work on 230 volts complete all as specified. |
| 181 | M & Lfor Sub main wiring with 2 single core PVCinsulated unsheathed cable, 1100v grade with FRLS PVC 6 sq mm copper cable multi stranded conductordrawn through in and including PVC rigid non metallic concealed conduit 20 mm dia, medium duty, ISI Marked to be terminated in DB boxas per IS including of 6 sqmm diaFRLS PVC Copper cable green colour asearth wire connected to earth complete,all as specified & directed. |
| 182 | M&L in replacement UNSV ofsub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dianot less than 20 mm dia with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductorof size 4.0 Sqmm as earth continuity conductor complete all as specified and directed.Notes for item No. 181 (i) Two run of single core PVC cable with one run ofearth conductor and conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc.for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces with using PVC rawl plugs) (iii) Make of cable : Plaza /Finolex /Havells/Shalabh/ Polycab/HPL/L&Tas approved by GE. (iv)Make ofPVC conduit & fittings : AKG / Asian /Plaza/Jindal /Avon/Finolex/National /Kalinga as approved by GE.) |
| 183 | M&Lin replacement UNSV ofsub main wiring using twosingle core PVC insulated, unsheathed stranded copper conductor cable of size 10 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade)of suitable dia not less than 32 mm dia with standard accessories along-with two run of PVC(green colour) insulated , unsheathed, stranded copper conductorof size 10 Sqmm as earth continuity conductor wall/ ceiling/concealed surface etc complete all as specified and directed. |
| 184 | S & F MCB single pole, 240 volts, 6 Amps to 32 Amp breaking capacity 10KA(type \"C\") complete,all as specified & directed. |
| 185 | Supply & Fixing MCB SPN, 240 Volts, 32 Ampsbreaking capacity 10 KA (type C curve) complete,all as specified & directed. |
| 186 | Supply and fixed in replacement of UNSVMCB 3 pole, 50/ 63 Amps415 volts, 50 Hz \"C\" Curve having breaking capacity 10 KA , with thermal magnetic protection unit and testing Complete all as specified and directed. Make- IndoAsian or equivalent in seimens / Schinder as approved by GE. |
| 187 | Supply and fixed in replacement of UNSVMCB 3 pole, 40Amps415 volts, 50 Hz \"C\" Curve having breaking capacity 10 KA , with thermal magnetic protection unit and testing Complete all as specified and directed. Make- IndoAsian or equivalent in seimens / Schinder as approved by GE. |
| 188 | S & F sheet metal enclosure MCB DBSPN 8 way with 200 amps rated bus bar 240 volts double door with isolated Neutral Bar & Shrouded bus bar IP protection 43 having door earthingcomplete all as specified and directed. |
| 189 | All as per item No 30 above but SPN, 240 volts, 12 ways complete all as specified and directed by GEMake: Legrand/ Havells/ C&S/Indoasian. |
| 190 | S & F sheet metal enclosure MCB DBVTPN 4 way with 200 amps rated bus bar 415 volts double door with isolated Neutral Bar & Shrouded bus bar IP protection 43 with incoming with MCCB having door earthing complete all as specified and directed. |
| 191 | Supply & FixingMCCB 100 Amp three pole Breaking capacity25 KA, complete,all as specified & directed. |
| 192 | Supply & FixingMCCB 160 Amp four pole Breaking capacity25 KA, complete,all as specified & directed. |
| 193 | Supply and fixing switch socket combination 6 pin 15 Amps flush type,240 volts (ISI Marked) complete,all as specified & directed. |
| 194 | Supply and fixing socket outlet 5 pin 5/6 Amps flush type polycarbonate body complete,all as specified & directed. |
| 195 | Supply and fixing switch flush type polycorbonate body, single pole, one way 6 Amp, 240 volts (ISI Marked) complete,all as specified & directed. |
| 196 | Supply and fixing switch flush type single pole one way 16 Amp polycarbonate body complete,all as specified & directed. |
| 197 | Supply and fixing socket outlet 2 in 1, 6 pin 5/15 Amps polycarbonate body complete,all as specified & directed. |
| 198 | Supply and fixing twin core flexible wire of size 40/0.0076 complete,all as specified & directed. |
| 199 | Supply and fixing twin core flexible wire of size 23/0.0076 complete,all as specified & directed. |
| 200 | Supply and fixing PVC insulated, FRLS, unsheathed single core, multistranded copper conductor industrial cable 1.5 Sqmm complete,all as specified & directed. |
| 201 | Supply and fixing PVC insulated, FRLS, unsheathed single core, multistranded copper conductor industrial cable 2.5 Sqmm complete,all as specified & directed. |
| 202 | Supply and fixing electronic 5 speed stepped socket type fan regulator of capacity including connectingup complete all as specified and directed. |
| 203 | Supply and fixing LED of 12 Watt 6000K,joy round recess mounted, compact vertical, round shaped down lighter with removable driver for low ceiling heights and all other connected all other connected accessories complete,all as specified & directed. |
| 204 | Supply only Hylum sheet 3 mm thick of size 4\" x 4\" including screws for fixing complete,all as specified & directed. |
| 205 | Supply only Hylum sheet 3 mm thick of size 7\" x 4\" including screws for fixing complete,all as specified & directed. |
| 206 | Supply & fixing Sunkan Box GI 1.22 mm thick of size 4\" x 4\"duly painted inside and outside with one coat of red oxide primer and two coats of black bituminous paint including cutting chasing and PCC work, plastering and making good the disturbed surface and matching with existing by white wash/distemper complete,all as specified & directed. |
| 207 | Supply and fixing Sunkan Box GI 1.22 mm thick of size 7\" x 4\"duly painted inside and outside with one coat of red oxide primer and two coats of black bituminous paint including cutting chasing and PCC work, plastering and making good the disturbed surface and matching with existing by white wash/distemper complete,all as specified & directed. |
| 208 | Supply only metalic plugtop suitable for 20 Amp socket outletcomplete all as directed. |
| 209 | Supply only metalic plugtop suitable for 6Amp socket outletcomplete all as directed. |
| 210 | Supply and fixing of sheet metal encloser with socket plug topSingle pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 A, 240V including taking out old sheet mental enclosures , cutting chasing & PCC work, plasteringmaking good the disturbed surface and matching with existing by white wash/distemper complete all as specified and directed. |
| 211 | Supply and fixing in replacement 1100 Volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed,one twin core cable flat or circular of aluminium stranded conductors of size 10 Sqmm complete,all as specified & directed. |
| 212 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt and electrode to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by galvanised iron light grade 15 mm dia pipe and GI Pipe 20 mm light grade for water filling including 15x20 mm reducer socket funnel wire mesh, RCC cover PCC chamber pit with PCC (1:3:6) type C-2 excavation and earth work, disposal of surplus spoil, to a distance not exceeding 50 mtrs all as specified and shown on electrical plate No. 5 of 2009 (Part-I) including taking out old existing earthing complete all as specified & directed. |
| 213 | Taking down carefully old obsolete electric/ electronic meters of any type by disconnecting all electrical connections and deposit to MES store yard complete all as specified and as directed.Note : (a)Taking down of old obsolete Meter shall be done after installation, trial & testing of new electric/ electronic meters.(b)All old meters are property of MES Department and Contractor shall be deposited to MES Store Yard . |
| 214 | Supply and fix single phase electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and as directed. |
| 215 | Supply and fix Three phase static energy meter of accuracy class 1.0, 3x240V, 50 Hz with optical port and with backlit LCD display of rating 20 to 100 Amp.e with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and as directed. |
| 216 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor, complete, all as specified and directed. |