| 1 | Dismantling of existing conducting and wiring, surface mounting box of light/plug/ telephone/LAN/bell push/fan regulator, holders, sockets & switch works, distribution board & MCB in the entire building at all heights or as directed by the engineer in charge, handing over the reusable material to the engineer in charge and devolution of scrap items to central store/thalakundah, etc., complete |
| 2 | Supply and fixing of TNEB meter board suitable for 32A three phase service connection with 3 Nos. 32A fuse unit (500V) 32A neutral link and earth link (1\" x 1/8\" copper flat) on TW plank of size 600mm x 450mm x 19mm with supporting TW reepers of 1\" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit. |
| 3 | Supply and run of 4 of 7/18 VIR cable wire with stranded circular non-compacted copper conductor for three phase service connection mains |
| 4 | Supply and run of 7/20 GI wire with pvc sleeve and necessary reel for three phase service connection mains |
| 5 | Supply and fixing of 32mm dia GI pipe (Class \"B\") suitably bent at both ends with necessary angle iron up right and end supports for mains |
| 6 | Supply and run of 1.0 sq.mm PVC insulated SC unsheathed copper conductor of 1100V grade with ISI mark inside wiring conduit system on wall and ceiling for sub main/circuit/Point wiring |
| 7 | Supply and run of 2.5 sq.mm PVC insulated SC unsheathed copper conductor of 1100V grade with ISI mark inside wiring conduit system on wall and ceiling for sub main/circuit/Point wiring |
| 8 | Supply and run of 4.0 sq.mm PVC insulated SC unsheathed copper conductor of 1100V grade with ISI mark inside wiring conduit system on wall and ceiling for sub main/circuit/Point wiring |
| 9 | Supply and fixing of 22W 4 feet LED Fitting on wall/false ceiling with PVC unsheathed Copper leads from terminal to the fitting |
| 10 | Re-fixing of dismantled existing LED light fittings after completion of fresh conducting and wiring work with fitting clamps, ceiling rose if necessary and PVC unsheathed Copper leads from terminal to the fitting. |
| 11 | Supply and fixing of 3 module plastic surface mounting box with necessary plastic module base & cover plate on wall, partitions, etc., complete |
| 12 | Supply and fixing of 4 module plastic surface mounting box with necessary plastic module base & cover plate on wall, partitions, etc., complete |
| 13 | Supply and fixing of 6 module plastic surface mounting box with necessary plastic module base & cover plate on wall, partitions, etc., complete |
| 14 | Supply and fixing of 8 module plastic surface mounting box with necessary plastic module base & cover plate on wall, partitions, etc., complete |
| 15 | Supply and fixing of 6A-230V modular switch 1W - 1 Module in plastic surface mounting box with necessary point wiring inside surface mounting box complete |
| 16 | Supply and fixing of 16A-230V modular switch 1W with indicator - 1 Module in plastic surface mounting box with necessary point wiring inside surface mounting box complete |
| 17 | Supply and fixing of 6A-230V modular socket - 2 Module in plastic surface mounting box with necessary point wiring inside surface mounting box complete |
| 18 | Supply and fixing of 16A-230V modular socket - 2 Module in plastic surface mounting box with necessary point wiring inside surface mounting box complete |
| 19 | Supply and fixing of 16A-230V modular socket - 3 Module in plastic surface mounting box with necessary point wiring inside surface mounting box complete |
| 20 | Supply and fixing of modular blanking plate/dummy - 1 Module in plastic surface mounting box complete |
| 21 | Supply and laying of rigid 25mm (1\") PVC conduit pipes or 25mm x 12mm cable trunking & ducting system with necessary conduit accessories, saddles, junction boxes, etc., complete |
| 22 | Supply and laying of rigid 20mm (3/4\") PVC conduit pipes or 20mm x 12mm cable trunking & ducting system with necessary conduit accessories, saddles, junction boxes, etc., complete |
| 23 | Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) accommodating 1No 32A DP MCB switch as incoming and 6 No\"s 6A to 32A SP MCB as outgoing on wall with earth connection. |
| 24 | Supplying and fixing of single pole 6A to 32A - 240/415V - 10 KA, miniature circuit breaker suitable for inductive load in the MCB DB complete with connections, testing and commissioning etc., complete |
| 25 | Supplying and fixing of double pole 6A to 32A - 240/415V - 10 KA, miniature circuit breaker suitable for inductive load in the MCB DB complete with connections, testing and commissioning etc., complete |
| 26 | Supplying and fixing of sheet steel enclosure for miniature circuit breaker, etc., complete |
| 27 | Supply and fixing of surface mounting CAT 6 PVC module gang box with single socket RJ-45 face plate & RJ-45 CAT 6 Keystone jack on surface mounted gang box for data outlet on wall/ partitions including crimping of UTP/Telephone cable with keystone jack complete, etc., complete |
| 28 | Supply and fixing of 1m length patch cord for data connectivity framework b/w Computer I/O Port & Gang box including CAT 6 cable, RJ-45 connector, etc., complete |
| 29 | Supply & fixing of 5-Port 10/100Mbps LAN network switches on surface by wall mounting including bunching of cables, connections, testing and commissioning complete |
| 30 | Supply & run of unarmoured CAT-6 Lan cable for data connectivity framework b/w switches & Gang box, inside conduit system or openly bunched with cable tile and hanged with saddles on wall and ceiling, including bunching of cables, connections, testing and commissioning complete |
| 31 | Earthing as per PWD standard with an earth electrode of 2 metre Class \"B\" GI pipe of dia not less than 32mm complete with necessary masonry work |
| 32 | Supply and fixing of 30W LED Street Light Fitting with LED on wall, street light post with 25mm dia GI pipe with 1 No GI bend, with PVC unsheathed Copper leads from terminal to the fitting, clamp, etc., complete |
| 33 | Supplying & laying in position of UPVC pipes of 20 mm dia including cost of cutting, joining and fixing UPVC plain specials using adhesives for external work, etc., complete |
| 34 | Supply and run of 3 core 2.5 sq.mm PVC insulated & sheathed flat type copper cable of 1100V grade with ISI mark inside wiring conduit system for sub main/circuit/Point wiring for electric appliances |
| 35 | Supplying and fixing of double pole 32A surface switch with Neon indicator complete with connections, testing and commissioning etc., complete |
| 36 | Dismantling fixed glazing and false ceiling, partitions, doors, windows, including clearing away/disposal of unserviceable material and stacking of serviceable material within 50 meters lead as directed by Engineer-in-charge. |
| 37 | Providing & fixing 12mm thick board pre-laminated on both sides for pannel in aluminium door with necessary rubber breading, aluminium clip, re-erction of aluminium door with necessary hinges, etc. complete as per the directions of engineer-in-charge. |
| 38 | Providing & fixing 4mm thick plain float glass for glazing pannel in panneled stell window with putty, etc. complete as per the directions of engineer-in-charge. |
| 39 | Repair works to wooden window shutter including sanding, applying wooden filler for gaps, replacing loose hardware, aligining tracks, etc. complete as per the directions of engineer-in-charge. |