| 1 | Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). |
| 2 | For fixed portionPowder coating aluminum( minimum thickness of powder coating 50 micron) |
| 3 | For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately).Powder coating aluminum( minimum thickness of powder coating 50 micron) |
| 4 | Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.) With float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm) |
| 5 | Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 50mmx48mm to aluminum window/vent with required screws, Y and H aluminium section (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge. Powder coating aluminum( minimum thickness of powder coating 50 micron) |
| 6 | Providing & Fixing BWR ISI marked 19 mm board of approved make for making wardrobe/shelves and other furniturewith fevicol & nails completeas per approved by engineer in charge. |
| 7 | Providing & Fixing mica of approved make for inner/outer side of shutters with fevicol & nails completeas per approved by engineer in charge. 0.8mm thick mica |
| 8 | Providing & Fixing of ward robe shutters made out of 19mm thick BWP block board ISI of superior quality make with following details Front side finishing with 1mm thick superior quality mica approved make and 0.8mm thickapproved shade mica in the inner side. Covering with teak wood beading 25x12mm all the sides of shutter & 35x12mm on outer frame for making good the wall joint including heavy brass S.S. fittings (Handle 200mm 2 Nos., Tower Bolt 150mm 2 Nos., Brass Lock 1 Nos., Magnetic Catcher 2 Nos., Brass Hinges 75x40x2.5 mm 6 Nos., SS Hanger Rod 20mm dia)complete as per drawing and design approved by Engineer in Charge. |
| 9 | Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge. Prelaminated particle board with decorative lamination on both sides. |
| 10 | Filling the gap upto 5 mm depth and 5 mm width in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. |
| 11 | Providing & fixing 12 mm thick tegular edge Glass Fibre Reinforced Gypsum False ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross |
| 12 | “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-Charge. |