Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-05-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 20-05-2025 |
| Sl. No. | Item Description |
| 1 | Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient forlaying cables/pipes etc. including removing cable protection covers/ bricks complete all as specified and directed. Notes : (i) Excavation shall be made carefully in order to avoid damage of existing cables and brick protection.(ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations. |
| 2 | M&L for Returning, filling in, including spreading leveling, watering and well ramming the excavated soil in layers not exceeding 25 cm thick complete all as specified and directed. |
| 3 | M&L for Removal of surplus excavated soil to a distance not exceeding 50 Mtr distance and depositing as directedat a level not exceeding 1.5 mtr above starting point complete all as specified and directed. |
| 4 | Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches/ducts for cable protection complete all as specified and directed.(NOTE : Thickness after punning shall be measured for payment) |
| 5 | M&L for Un-reinforced precast concrete cable cover class LV type I, flat, size 250mm x 150mm x 40mm as proteciton to under ground cable laid dry flat adjoining each other complete all as specified and directed |
| 6 | Disconnecting and taking out old unserviceable GI pipe and Supplying, laying & jointing GI water tubing, 50 mm bore, light grade as in sleeving etc laid in trenches / pole post etc, cutting and making necessaries arangement by means of wedling and jointing suitable for post of larntent/ street light fitting including PCC work complete all as specified and directed . Make of pipe TATA / Jindal / Swastik / Prakash / BSTor any other ISI marked make approved by GE.(Note : PCC work shall be measured and paid seperatly under Sch \"A\" relevent item) |
| 7 | Disconnecting and taking out old existing unserviceable/ non- functional LT Cable and Supplying, laying, jointing and testing cable XLPE insulated IS 7098 (Part-I)-2009 marked, screened, PVC sheathed, armoured electric power cable (heavy duty) with aluminum conductor for working voltage upto and including 1100 Volts, cross sectional area of under mentioned size of cables laid in trenches/fixed on pole/wall / passed through pipe complete all as specified and directed. Make:Havells/GLOSTER/Polycab) (NOTE: Earth work, sand cushioning, pipe, clamps for holding cables and brick protection shall be measured and paid separately ) |
| 8 | 6 Sqmm 2 core |
| 9 | 10 Sqmm 2 core |
| 10 | 16 Sqmm 2 core |
| 11 | 16 Sqmm4 core |
| 12 | 25 Sqmm4 core |
| 13 | Labour only for checking the serviceability of the different spares / components / parts of security light fittings/post top lantern light fittings (LED,HPSV, Metal Halide, flood lightfittings etc, any wattage/capacity) of any description and fixed in any position, replacement of un-serviceable/damaged/ broken part(s) either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete all as specified and directed here in after in notes. NOTES FOR SCH `A’ ITEM NO 13:-(i) Replacement of parts i.e Drivers,SPD, LED board,lamps, choke, Igniter, Condenser, Holder, covers etc for Street/Flood light fittings any wattage & capacity, if any required at site, shall be measured and paid for separately under appropriate item of Schedule `A\" as ‘supply only. (ii) Necessary T&P i.e. ladder, tools etc required for checking and making the light fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of street light fittings/security light fittings of any description on poles / on walls / on pillars etc i.e. in any position at site.(iii)Required screws, insulating tapes, internal wiring wire and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item.(iv)Contractor shall be paid only one time the labour charges quoted above in Schedule `A\" items for a particular fitting repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the fittings and replacement of unserviceable / defective parts in order to maintain the fittings in serviceable/working condition. (v) Contractor’s quoted rates for Schedule `A\" item No 9 is deemed to include for inspection/checking the serviceability of the fittings in position or by taking down as per site requirement, removing the damaged unserviceable / broken parts, fixing the new parts as required, fixing the fittings in same position or the other, connecting the fittings with electric source and testing of fittings as directed. |
| 14 | Supply onlythe following parts for LED fittings complete all as specified and directed. NOTES:(i) Fixing element of these items is deemed to be included in the rates quoted by the contractor for Sch `A\" item No 14(ii) Spare parts/items shall be of make Crompton Greaves/Philips/Bajaj/Havells & suitable for the existing fittings.(iii) The above items shall be operated with prior written approval of GE and when required spares are not available with the deptt to issue to contractor under Sch ‘B’ “Free for fixing” and Contractor shall have no claim on account of non execution of above items. |
| 15 | Driver Suitable for 45/48Watt LED fittings.Make:C&S/Havells/Bajaj/Crompton |
| 16 | Driver Suitable for 60Watt LED fittings, Make:C&S/Havells/Bajaj/Crompton |
| 17 | Driver Suitable for 90Watt LED fittings,Make:C&S/Havells/Bajaj/Crompton |
| 18 | Driver Suitable for 100/120/150Watt LED fittings.Make:C&S/Havells/Bajaj/Crompton |
| 19 | Safety Protection Device (SPD). Make:C&S/Havells/Bajaj/Crompton |
| 20 | Taking down existingunserviceablebracket complete and S&F 32 mm dia GIlightgrade pipe bracket 1.50 m long bent to shape by cutting & weldingas required & directed and fixed to pole withtwo Nos of FI clamps 40x5 mm to be tightened with bolts, nut and washers and including painted withtwo coat of aluminium paint over a coat of red oxide primer complete all as specified and directed.Make of pipe TATA / Jindal / Swastik / Prakash / BSTor any other ISI marked make approved by GE. |
| 21 | Supply and fixing in replacement of UNSV 20W LED Post top lantern complete accessories to be fixed on pole/wall includingconnecting the fitting to control switch at the bottom of the pole with using 2.5 Sqmm two single core PVC insulated and unsheathed copper conductor cable complete,all as directed and directed. Make : Cromptonof /Havells/ C&S/Bajaj/Shakti.(Note :PCC work shall be measured and paid seperatly under Sch \"A\" relevent item and rate of cable deemed to be included ) |
| 22 | Supply and fixing in replacement of UNSV 40W LED Post top lantern complete accessories to be fixed on pole/wall includingconnecting the fitting to control switch at the bottom of the pole with using 2.5 Sqmm two single core PVC insulated and unsheathed copper conductor cable complete,all as directed and directed.Make : Crompton/ Havells/ C&S/Bajaj/ Shakti. (Note :PCC work shall be measured and paid seperatly under Sch \"A\" relevent item and rate of cable deemed to be included ) |
| 23 | Taking down old unserviceable MS junction boxes from the pole with disconnectiong all connections, Supplying and fixing in position new Pole box made of thermoplastic Polycarbonate having IP65/IP66 degree of protection (shock proof, dust proof, jet water proof and acid resistive). The gasket should be internally embedded, and made of Polyeutherene. The boxes shall be tested as per IEC 60670-2/ 60670-22. The boxes shall have self threaded holes & provision for mounting din rail. The lid should be hinged type with sealing screw. The screw should be of stainless steel so that there is no corrosion. The boxes should withstand temperature of -40c to +120c. The glow wire test should be conducted at 960 c or 750 c and material should be flame retardant & self extinguishing. UL subject 94, V-0. The boxes should be free from toxic substances like hal ogen and silicon. The boxes should have suitable pre-moulded knock out /or plan wall depending on requirement. Box dimension shall not be less than 205 X 255 X112 MM (LXBXH). Box shall be suitable for 16/25Sqmm cables including one no. MCB SP 230 volts 6 amps of make Havells/Legrand/ABBand connecting the bus bars to cables withusing suitable GI nut, bolts and washers and aluminum lugs etc fixed on pole using 30x5mm FI clamps,nuts,bolts & washers complete all as specified and directed.Make: Hensel/GE/Legrand. |
| 24 | Material & labourof PCC 1:3:6 type C-2 using 20 mm graded stone aggregate (4 stay). in mass concrete and filling completefor foundation/hard standing coping ,complete all as specified and directed. |
| 25 | M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling of poles and mass concrete etc complete all as specified and directed. |
| 26 | M & L for cutting chases in hard standing road/path/drain etc for passing cables/pipes etc. size of and removing the excavated materials and disposal at 50 metre distance and making good the cutting after the pipe and cables are laid with PCC 1:3:6 type C-1 using 20mm graded stone aggregates complete all as specified and directed. |
| 27 | Supplying,erecting and fixing in replacement of UNSV steel tubular swaged pole (410 SP – 31), 9 mtr long,in true vertical position complete conforming to IS : 2713 (Part-I & III) 1980 with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole with and including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole finished with one coat of red oxide primer complete, all as specified and directed. (Note : Excavation and PCC work shall be measured and paid seperatly under Sch \"A\" relevent item) |
| 28 | Supply, fixing & testing in replacement of UNSV20W LED street light with corbonate cover with high inpact resistance, 15 W-1500 lumens with efficacy of 100 lumans /wall at system level, ingress protection of IP65 PF-0.9 & with input resistanct i.e.IK 09 surge protectin upto 4KV,compiled withIS 10322 CCT is greater than 5000K,complete with all accessories duly prewired, supply and fixing the bracket of 40 mm dia 60 cm long GI pipe light grade bent to shap and including MS FI clamp of 20X3 mm nut and bolts and connected with flexible cable 3 core copper conductor 0.5 Sqmm upto ceiling rose complete mounting on existing MS frame bracket including connecting the fitting complete, all as specified and directed.Make-Crompton / Havells/C& S/Bajaj/ Shakti. (Note :- GI pipe bracket and clamp shall be measured and paid seperatly under Sch \"A\" relevent item) |
| 29 | Supply, fixing & testing in replacement of UNSV25W LED street light with corbonate cover with high inpact resistance, 15 W-1500 lumens with efficacy of 100 lumans /wall at system level, ingress protection of IP65 PF-0.9 & with input resistanct i.e.IK 09 surge protectin upto 4KV,compiled withIS 10322 CCT is greater than 5000K,complete with all accessories duly prewired, supply and fixing the bracket of 40 mm dia 60 cm long GI pipe light grade bent to shap and including MS FI clamp of 20X3 mm nut and bolts and connected with flexible cable 3 core copper conductor 0.5 Sqmm upto ceiling rose complete mounting on existing MS frame bracket including connecting the fitting complete, all as specified and directed.Make-Crompton / Havells/C& S/Bajaj/ Shakti. (Note :- GI pipe bracket and clamp shall be measured and paid seperatly under Sch \"A\" relevent item) |
| 30 | Supply, fixing & testing in replacement of UNSV45W LED street light IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewiredand suitable fixing arragement for mounting on existing MS framebracketincluding connecting the fittingcomplete all as specified and directed.Make-Crompton / Havells/C& S/Bajaj / Shakti. (Note :- GI pipe bracket and clamp shall be measured and paid seperatly under Sch \"A\" relevent item) |
| 31 | Supply, fixing & testing in replacement of UNSV60W LED street light IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewiredand suitable fixing arragement for mounting on existing MS framebracketincluding connecting the fittingcomplete all as specified and directed.Make- Crompton / Havells/C& S/Bajaj). (Note :- GI pipe bracket and clamp shall be measured and paid seperatly under Sch \"A\" relevent item) |
| 32 | Supply, fixing & testing in replacement of UNSV90W LED street light IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewiredand suitable fixing arragement for mounting on existing MS framebracketincluding connecting the fittingcomplete all as specified and directed.Make- Crompton/Havells/C& S/Bajaj/ Shakti. (Note :- GI pipe bracket and clamp shall be measured and paid seperatly under Sch \"A\" relevent item) |
| 33 | Supply, fixing & testing in replacement of UNSV120W LED street light IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewiredand suitable fixing arragement for mounting on existing MS framebracketincluding flexible cable 3 core copper conductor 0.5 Sqmm upto ceiling rose complete mounting on existing MS frame bracket including connecting the fitting complete all as specified and directed.Make- Crompton /Havells /C& S/Bajaj/ Shakti. (Note :- GI pipe bracket and clamp shall be measured and paid seperatly under Sch \"A\" relevent item) |
| 34 | Supply, fixing & testing in replacement of UNSV 50W LED Flood light (Orange, White & Green) colour full IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewiredand suitable fixing arragement for mounting on existing 16 mtrs High Mast/11 mtrs pole /9 mtrs poleor Bldg MS frame/bracketincluding connecting the fittingcomplete all as specified and directed. Make- Crompton/Havells/C& S/Bajaj/Shakti (Note : GI pipe bracket shall be measured and paid seperatly under Sch \"A\" relevent item) |
| 35 | Supply, fixing & testing in replacement of UNSV LED Highmast LED IP 65 luminaire with high efficiacy light fittings 200 watts with all aecessaries complete on Pole and building wall/ ceiling comple (Make- Crompton /Havells /C& S/Bajaj). |
| 36 | Material and labour for cleaning and preparation of all existing steel surfaces of straight Electric/ steel tubular poles 9 mtrs long for painting including mild steel cross arms, clamps and street light brackets,protection pipe, MS boxes etc and applying Two coat of aluminium paint all round the exposed steel surfaces of existing steel tubular poles of any description and in any position above the height of 1.50 mtr from the plinth of the pole and applying one coat of synthetic enameled paint of different colours in strips of 150mm width upto the height 1.5 mtr from the plinth of polecomplete all as specified and directed. |
| 37 | Material and labour for cleaning and preparation of all existing steel surfaces of straight Electric/ steel tubular poles 11 mtrs long for painting including mild steel cross arms, clamps and street light brackets,protection pipe, MS boxes etc and applying Two coat of aluminium paint all round the exposed steel surfaces of existing steel tubular poles of any description and in any position above the height of 1.50 mtr from the plinth of the pole and applying one coat of synthetic enameled paint of different colours in strips of 150mm width upto the height 1.5 mtr from the plinth of polecomplete all as specified and directed. |
| 38 | M & L for re-writing letters or figures (Black, roman, Indian)for electric/ street light pole Nos on existing poles with stencilout with black colour including fixing red colour radium of 80 mm hight arround the radius of pole complete all as specified and directed. |
| 39 | M&L in replacement of UNSV cross arms, bracing, supports, clamps and black plates fabricated from structural steel sections including nut,bolts and washer welding, bending cold or hot ,drilling holls for bolts in any shape or size as indicated or directed and inclisive one primer coat one under coat and one finishing coat of paintscomplete all as specified and directed. |
| 40 | Taking down of carefully unserviceable Aluminium/copperpoint wiring (light, fan socket or power) complete with fitting such as switches, ceiling rose lamp holder, sockets, fan regulators, SK/FTL light fittings etc removing materials for store for keeping in safe custody or for taking credit (credit for above items should be taken as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed. |
| 41 | M&L for point wiring with single corePVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI markednot less than 20mm dia, concealed conduit wiring in walls and surface with GI saddles GI screws, rawal plugs in ceiling or roof if not possibleincluding Tee, Junction boxes and provision offlush metal boxes, inner and outer plate suitable for modular switch, socket and fan regulator as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi strandedcopper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for one light/Fan point controlled by one Switch complete all as specified and directed. |
| 42 | All as per Srl item No 41 above but point wiring for one bell/buzzer point controlled by one push button on the same board with other switches or independent complete all as specified and directed. |
| 43 | All as per Srl item No 41 above for point wiring for 5 pin switch socket outlet, 5/6 Amps on same board with other switches complete all as specified and directed. |
| 44 | All as per Srl item No 41 above for point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board complete all as specified and directed. |
| 45 | All as per item No 41 above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sqmm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete all as specified and directed.Make of cable and conduit: Havells/ Plaza/ Kalinga. |
| 46 | All as per item No 41 above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4 Sqmm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete all as specified and directed.Make of cable and conduit: Havells/ Plaza/ Kalinga.Note for item 41 to 46 here in before : (i) The quoted rates shall be deemed to be inclusive for cutting chasesin brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at RCC Columns/Beams/Ceilings shall be in surface conduit of suitable size fixed on surface with using PVC rawl plugs . (ii) Rate for modular metal flush boxes ,inner and outer plate with frames are deemed to be included in the quoted rate by contractor for above items. (iii)Fittings like Modular switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A\". (iv) The size of conduits shall be determined on permissible No. of runs of wires as specified in SSR Part-I (2009) clause 19.125 (B). However minimum size of conduit shall be 20mm dia (Medium grade(v) Make of cable : Finolex /Havells/ Poly cab as approved by GE.(vi)Make ofPVC conduit & fittings : AKG / Asian /Plaza/Jindal /Avon/Finolex/National /Kalinga as approved by GE. |
| 47 | S&F Modular switch pianosingle pole one way 6 amp complete all as specified and directed. Make -Legrand / Anchor Penta / Crabtree/MK/HPL as approved. |
| 48 | S&F Modular switch pianosingle pole one way 16 amp complete all as specified and directed. Make - Legrand / Anchor Penta / Crabtree/MK/HPL as approved. |
| 49 | S&F Modular bell push,6 amp 240 volts complete all as specified and directed. Make - Legrand / Anchor Penta / Crabtree/MK/HPL as approved. |
| 50 | S&F door bell, AC, 240 volts, single pole complete all as specified and directed. Make - Legrand / Anchor Penta / Crabtree/MK/HPL as approved. |
| 51 | S&F Modular socket outlet2/3 pin combined 2 module 6/16 amp complete all as specified and directed. Make -Legrand / Anchor Penta / Crabtree/MK/HPL as approved. |
| 52 | S&F Modular socket outlet2/3 pin combined 2 module 6 amp complete all as specified and directed. Make -Legrand / Anchor Penta / Crabtree/MK/HPLas approved. |
| 53 | S&F ceiling rose 3 plates polycarbonate, isolated body complete all as specified and directed.Make - Legrand / Anchor Penta / Crabtree/MK/HPL as approved. |
| 54 | S&F Angle holder, insulated polycabonate body with back plate suitable for batten fittings complete all as specified and directed . Make of holder - Legrand / Anchor Penta / Crabtree/MK/HPL and Make of LED - Havells / Philips/ C&Sas approved. |
| 55 | S&F LEDlamp/bulb 12/15 watt ,Lumen out put 950, 6500 K , B22complete all as specified and directed. |
| 56 | Supply and fixing LED tube light fitting 220V,AC decorative box type with driver, holder complete alll as specified and directed |
| 57 | S&F modular fan step regulator 120 W 2 module complete all as specified and directed. Make: Legrand / Anchor Penta / Standard/Crabtree as approved. |
| 58 | S&F in replacement of UNSV of Surface and wall mounted20 W LED Batten with polycarnonate housing & Integrated electronic driver, and all accessories pre wired including connecting to mains complete all as specified and directed. Make: Havells or euivalent in Philips/C&S/ Crompton & Greaves. |
| 59 | S&F in replacement of UNSV of Recess mounted 36 watts, 6500 k,4\"x1\" LED ceiling light fittings with slim line extruded aluminium / CRCA body, opal acrylic diffuser, electrinic driver etc and all accessories pre wired including connecting to mains complete all as specified and directed. Make: Havells or euivalent in Philips/C&S/ Crompton & Greaves. |
| 60 | S&Fin replacement of UNSV LED mirror light fitting, 10 watts, 1000 lumens 6500K comprises of aluminium extruded channel, frosted diffuser, integrated electronic driver, IP 20 protection and all accessories pre- wired including connecting to mains complete all as specified and directed. Make-C&G or equivalent in Havells/Phillips |
| 61 | S&F in replacement of UNSV bulkhead fitting with integrated LED bulk head fitting 10W 600 lumens, 6000 K comprises of pressure die cast housing, acrylic diffuser and frame IP 65 protection, IK-07 etcincluding connection complete all as specified and directed. Make- C&G or equivalent in Havells/Phillips as approved. |
| 62 | S&F in replacement of UNSNDecorative, Wall mounting champagne gold finish fixture with plastic body along with 9 W LED lamp B22 base as per Havells or equivalent in Philips/C&S as approved complete all as specified and directed. |
| 63 | Supplying, fixing & testing in replacement UNSVrecess mounting in built ,36 Watts,2\"x2\" LED ceiling light fitting with slim line extruded aluminium/ CRCA body, opal acrylic diffuser, electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed.Make- C&G Cat Pt No LCTLRNE-36-FO-CDL or equivalent in Phillips/Havells as approved. |
| 64 | Supplying & fixing, testing in replacement UNSV of surface mounted in built , LED 18 watts, 1\"x1\" LED ceilinglight fitting with slim line extruded aluminium/ CRCA body, opel acrylic diffuser, electronic driver etc and all accessories pre-wired including connecting to source complete all as specified and directed. Make- Crompton cat pt No- LCTLSNE-18-FO-CDL or equivalent model of Havells / Philips as approved . |
| 65 | S&F in replacement ofSingle pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole and neutral MCB 20 amp,240Volts power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet with and including one number single pole \"C\" series MCB 16/20 amp as required. Make of MCB SP 16/20 Amp- IndoAsian orequivalent in Legrand/Seimens/Schneider Make of SPN DB with MCB 20Amp - CAt PT No 811956 of Indo Asian or equivalent in Legrand/Schneider as approved. |
| 66 | M&L in replacement UNSV ofsub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dianot less than 20 mm dia with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductorof size 4.0 Sqmm as earth continuity conductor complete all as specified and directed.Notes for item No. 66 (i) Two run of single core PVC cable with one run ofearth conductor and conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc.for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces with using PVC rawl plugs) (iii) Make of cable : Plaza /Finolex /Havells/Shalabh/ Polycab/HPL/L&Tas approved by GE. (iv)Make ofPVC conduit & fittings : AKG / Asian /Plaza/Jindal /Avon/Finolex/National /Kalinga as approved by GE.) |
| 67 | M&Lin replacement UNSV ofsub main wiring using four single core PVC insulated, unsheathed stranded copper conductor cable of size 10 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade)of suitable dia not less than 32 mm dia with standard accessories along-with two run of PVC(green colour) insulated , unsheathed, stranded copper conductorof size 10 Sqmm as earth continuity conductor wall/ ceiling/concealed surface etc complete all as specified and directed. |
| 68 | M&Lin replacement UNSV of sub main wiring using four single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade)of suitable dia not less than 32 mm dia with standard accessories along-with two run of PVC(green colour) insulated , unsheathed, stranded copper conductorof size 6 Sqmm as earth continuity conductor complete all as specified and directed. Notes for Item 66 & 67 here in above: (i) Four run of single core PVC cable with two run ofearth conductor andone run of conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc.for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces with using PVC rawl plugs)(iii) Make of cable : Plaza /Finolex /Havells/Shalabh/ Polycab/HPL/L&Tas approved by GE. (iv)Make ofPVC conduit & fittings : AKG / Asian /Plaza/Jindal /Avon/Finolex/National /Kalinga as approved by GE.) |
| 69 | S&Fin replecement of UNSVvertical type load line distribution board ,double door, 8 way,AC 3 Phase 415 volt with TPN bus bar 250 Amps for each phase with 2 Neutral bar, 2 Earthbar and cable ties for cable management,fully insulted busbar & shrouded Neural bars ,improved Pan assembly for each insullation ,prefittedmasking sheeet,reversibledoor for IP 43-\"IK 09 with metal doorwith provision for DPX3 160 MCCB as incomer and SP/TP MCB\"s as out going complete all as specified and directed.. Make of VTPN DB:-IndoAsian cat Part No-811896 or equivalent make inHavells/L& T. Make of MCCB:- IndoAsian or equivalent make inHavells/L& T |
| 70 | All as per item No 44 above but4way complete all as specified and directed.Make of VTPN DB:-IndoAsian cat Part No-811893 or equivalent make inHavells/L& T. Make of MCCB:- IndoAsian or equivalent make inHavells/L& T |
| 71 | S&F in replacement of UNSV MCB distribution board SPN, 240 volts, 4 ways , powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 42- IK-09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with following ratings & ways:-Note:(i) MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. Make: Legrand or equivalent in Havells/L&T/Schneider/ IndoAsian as approved |
| 72 | All as per item No 71 above but SPN, 240 volts, 8 ways. Make -Legrandor equivalent in Havells/L&T/Schneider/ IndoAsian as approved. |
| 73 | All as per item No 71 above but SPN, 240 volts, 12 ways. Make - Legrand or equivalent in Havells/L&T/Schneider as approved.Notefor Item No.71 to 73 (i) Fittings like MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. (ii) -Sheet steel enclosure to be fixed flush to wall by cutting niche & make good to the disturbed wall surface as per existing (iii) Rate forIncomer MCCB is deemed to be included under above item. |
| 74 | Supply and fixed in replacement of UNSVMCB 3 pole, 50/ 63 Amps415 volts, 50 Hz \"C\" Curve having breaking capacity 10 KA , with thermal magnetic protection unit and testing Complete all as specified and directed. Make- IndoAsian or equivalent in seimens / Schinder as approved by GE. |
| 75 | S & F in replacement of unserviceable MCB SPN 240 volts \"C\" Curve suitable for fixing in MCB DB of capacity 6 to 32 amps complete all as specified and directed. Make - IndoAsianor equivalent in Hager or Schneider as approved. |
| 76 | S & F in replacement of unserviceable MCB SP 240 volts \"C\" Curve suitable for fixing in DB of capacity 6 to 32 Amps complete all as specified and directed.Make -IndoAsian or equivalent in Hager or Schneider as approved. |
| 77 | M&L for earthing complete for bldgwith galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm diaby means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel,PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish ,internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (2009) and specified includingprovision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete,all excavation andearth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed.NOTE : RCC pit cover shall be pre-cast of RCC (1:2;4) type B-1 80 mm thick reinforced with XPM weighting not less than 4 Kgs/Sqm in lieu of CI cover. |
| 78 | S&F in replacement of UNSV modular switch socket combination universal type 6/16 Amps with box (2 hole complete all as specified and directed with suitable connection with 1x1.5 sqmm and 1x1.5sqmm single core cable length upto 01 mtr Make Legrand/Anchor Penta/Crabtree as approved. |
| 79 | S&F in replacement of UNSV modular switch socket combination universal type 6Amps with box (2 hole complete all as specified and directed with suitable connection with 2x2.5sqmm and 2x2.5 sqmm single core cable length upto 01 mtr Make Legrand/Anchor Penta/Crabtree as approved. |
| 80 | S&F replacement of UNSV galvanized pressed steel terminal boxes concealed in wall of thickness 1.12 mm covered with phenolic laminated white sheet cover 3 mm thickin renewal of wooden/rusted boards of size 200 mm x 250 mm x 60 mm deep complete all as specified and as directed. |
| 81 | S & F in replacement of UNSV switch piano single pole flush type 5 amps, 230 volts complete all as specified and as directed. |
| 82 | S&F in replacement of UNSV socket out let 3 pin 5 Amps flush type complete all as specified and as directed. |
| 83 | S&F in replacement of UNSV switch piano flush type single pole way15 Amps complete all as specified and as directed. |
| 84 | S&F in replacement of UNSV socket outlet 2 in 1 3 pin 5/15 Amps flush type complete all as specified and as directed. |
| 85 | S&F in replacement of UNSN phenolic laminated white sheetcover 3.0 mm thick, cut into required size suitable for fixing on existing boards / terminal boxes for mounting switches, sockets, regulators as required complete all as specified and directed. |
| 86 | Supply and fixing LED tube light fitting 220V,AC decorative box type with driver, holder complete alll as specified and directed |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail