| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.All kinds of soil(Consider only 60% of total Qty) |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. Ordinary rock .Ordinary rock (Consider only 40% of total Qty) |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil (Consider only 60% of total Qty) |
| 4 | Earth work in excavation by mechanical means (Hydraulicexcavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan)includingdressing of sidesand ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. Ordinary rock(Consider only 40% of total Qty) |
| 5 | Fillingavailableexcavatedearth(excludingrock)intrenches,plinth,sidesof foundationsetc.inlayersnotexceeding20cmindepth,consolidatingeach deposited layer by ramming and watering, lead up to 50 m and lift up to1.5 |
| 6 | Providingandlayinginpositioncementconcreteofspecifiedgradeexcluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 9 | Providing and laying in position specified grade of reinforced cement concrete excludingthecostofcentering,shuttering,finishingandreinforcement-All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from naturalsources:4gradedstoneaggregate20mmnominalsizederivedfrom natural sources) |
| 10 | Reinforcedcementconcreteworkinwalls(anythickness),includingattached pilasters,buttresses,plinthandstringcourses,fillets,columns,pillars,piers, abutments,posts andstruts etc.uptofloorfivelevel excludingcost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources): |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels,beams,plinth beams and girders, bressumers and cantilevers. |
| 12 | Reinforcedcementconcreteworkinbeams,suspendedfloors,roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 13 | SteelreinforcementforR.C.C.workincludingstraightening,cutting,bending, placing in position and binding all complete upto plinth level.Thermo- Mechanically Treated bars. |
| 14 | Randomrubblemasonrywithhardstoneinfoundationandplinthincluding levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand).Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 15 | Randomrubblemasonrywithhardstoneinsuperstructureaboveplinthlevel and upto floorfive level, includingleveling up with cement concrete1:6:12 (1 cement:6coarsesand:12gradedstoneaggregate20mmnominalsize)at window sills, ceiling level and the like. Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 16 | Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars atevery third course of masonry work. |
| 17 | Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing \"C\" wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to 1000 mm c/c. Inverted triangle shaped Spring Tee having the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/ sqm (both side inclusive), fixing with clip in tiles into spring T with : 12.54.1 GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. |
| 18 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) |
| 19 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) |
| 20 | Providing & fixing in position Phenol bonded Bamboo wood in wall skirting with planksofsizes14mmthick,1900mmlength(minimum)and85mm wide(minimum),inapprovedcolour,textureandfinish,havingPerformance Appraisal Certificate (PAC) issued by Building Materials & Technology Promotion Council(BMTPC). Theskirting shallbe fixedwith SSscrews&rawl plugs,over underlayment of 4mm thick, expanded polyethylene foam sheets having 40kg/cumdensityoverpreparedsurface.Thebamboowoodplanksshallhave minimumdensityof1000Kg/cum&minimumHardness1000Kgf.withEco friendly UV coating, all complete as per direction of the Engineer in-charge. |
| 21 | ProvidingandlayingVitrifiedtilesinfloorindifferentsizes(thicknesstobe specifiedbythemanufacturer)withwaterabsorptionlessthan0.08%and conformingto IS:15622, of approvedbrand & manufacturer, in all coloursand shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing withgrey cementslurry @3.3 kg/sqm includinggrouting thejointswithwhite cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutteronly . Laying of tiles willbe done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Size of Tile 600x600 mm |
| 22 | ProvidingandfixingGlClipinMetalCeilingSystemof600x600mmmodule which includes providing and fixing \"C\" wall angle of size 20x30x20 mm made of0.5mmthickprepaintedsteelalongtheperimeteroftheroomwithhelpof nylon sleeves and wooden screws at 300 mm center to centre, suspending the mainCcarrierofsize10x38x10mmmadeofG.Isteel0.7 mmthickfromthe soffitwithhelpofsoffitcleat37x27x25x1.6 mm,rawlplugsofsize38x12 mm and C carrier suspension clip and main carrier bracket at height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to 1000 mm c/c. InvertedtriangleshapedSpring Tee having the main C carrierand in direction perpendiculartoitat600mmcenterswithhelpofsuspensionbrackets. WhereverthemainCcarrierandspringThavetojoin,CcarrierandspringT connectors have to be used. All sections to be galvanized @ 120 gms/ sqm (both side inclusive), fixing with clip in tiles into spring T with : 12.54.1 GI Metal Ceiling Clip in plainBeveled edge globalwhite colortiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. |
| 23 | Providing, fabricating and supplying shadow box of required size and shape,for fixinginthespandrelportionofthestructuralglazing,inlinearaswellas curvilinear portions of the building by providing semi -rigid, inorganic, noncombustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulationlayer shallhave facing(factorybondedon surface#1ofthefibreglassinsulationlayer),ofblacknon-wovenfibreglass tissueofnominalthickness0.5mmandnominalmassnotlessthan60gm/ sqm, made of randomly oriented glass fibres distributed in a binder by a wetlay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete |
| 24 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand)and jointing with grey cement slurry @3.3kgpersqmincludingpointinginwhitecementmixedwithpigmentof matching shade complete. |
| 25 | ProvidingandlayingCeramicglazedfloortiles300x300mm(thicknesstobe specifiedbythemanufacturer)of1stqualityconformingtoIS:15622of approvedmakeinallcoloursshadesexceptWhite,Ivory,Grey,FumeRed Brown,laidon20mmthickCementMortar1:4(1Cement:4Coarsesand) includingpointingthejointswithwhitecementandmatchingpigmentetc., complete. |
| 26 | Providingwoodworkinframesofdoors,windows,clerestorywindowsand other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Kiln seasoned and chemically treated hollock wood |
| 27 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessaryscrewsshallbe paid separately).Kiln seasonedand chemically treated hollock wood. 35 mm thick shutters |
| 28 | Providingandfixingpanellingandglazinginpanelledorpanelledandglazed shutters for doors , windows and clerstory windows (Area of opening for panel insertsexcluding portioninside groovesor rebates to be measured). Panelling for panelled or panelled or panelled andglazed shutters 25 mm to 40 mm thick: Kiln seasoned and chemically treated hollock wood |
| 29 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges brightfinishedofrequiredsizewithnecessaryscrews.Kilnseasonedand chemically treated hollock wood. 35 mm thick |
| 30 | ProvidingandfixingaluminiumslidingdoorboltsISImarked anodised(anodic coatingnotlessthangradeAC10asperIS:1868)transparentordyedto required colour or shade with nuts and screws etc. complete : 250x16 mm |
| 31 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating notlessthangradeAC10asperIS:1868)transparentordyedtorequired colour or shade with necessary screws etc. complete :200x10 mm |
| 32 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 100 mm |
| 33 | Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 34 | Providingandfixingprecoatedgalvanisedironprofilesheets(size,shapeand pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns.Sheetshouldhaveprotectiveguardfilmof25micronsminimumto avoidscratcheswhiletransportationandshouldbesuppliedinsinglelength upto12metreorasdesiredbyEngineer-in-charge.Thesheetshallbefixed usingselfdrilling/selftappingscrewsofsize(5.5x55mm)withEPDMseal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the costofpurlins,raftersandtrussesandincludingcuttingtosizeandshape wherever required. |
| 35 | Providingandfixingprecoatedgalvanisedsteelsheetroofingaccessories0.50 mm + 0.05 % total coated thickness, Zinc coating 120gsm as per IS: 277 in 240 mpasteelgrade,5-7micronsepoxyprimeronbothsideofthesheetand polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) |
| 36 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats @ 3.84 kg/10 Sqm complete.) |
| 37 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 38 | Makingplinthprotection50mmthickofcementconcrete1:3:6(1cement:3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand including finishing the top smooth |
| 39 | Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position : Kiln seasoned and chemically treated hollock wood |
| 40 | Extra for providing and fixing wind ties of 40x 6mm flat iron section |
| 41 | Providingandfixingwaterclosetsquattingpan(IndiantypeW.C.pan)with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making goodthewallsandfloorswhereverrequired:WhiteVitreouschinaOrissa pattern W.C. pan of size 580x440mm with integral type foot rests. |
| 42 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40mm flush bend, overflow arrangementwithspecialsofstandardmakeandmosquitoproofcouplingof approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid. |
| 43 | ProvidingandfixingwashbasinwithC.I.brackets,15mmC.P.brasspillar taps,32 mm C.P. brass waste of standardpattern, includingpainting of fittings and brackets,cuttingandmakinggoodthewallswherever require:White VitreousChinaWashbasinsize630x450mmwithasingle15mmC.P.brass pillar tap |
| 44 | ProvidingandfixingP.V.C.wastepipeforsinkorwashbasinincludingP.V.C. waste fittings complete. Flexible pipe of 40mm dia |
| 45 | Providingandfixing600x450mmbevelededgemirrorofsuperiorglass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 46 | ProvidingandfixingC.P.brassbibcockofapprovedqualityconformingto IS:8931 15 mm nominal bore |
| 47 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominalbore |
| 48 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore |
| 49 | ProvidingandfixingP.V.C.wastepipeforsinkorwashbasinincludingP.V.C. waste fittings complete.32 mm dia |
| 50 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brassthreaded fittingsThisincludesjointingofpipes&fittingswithonestepCPVCsolvent cement,trenching,refilling&testingofjointscompleteasperdirectionof Engineer in Charge. 25 mm nominal dia Pipes |
| 51 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittingswith one step CPVC solventcement and thecost ofcutting chasesandmakinggoodthesameincludingtestingofjointscompleteasper directionofEngineerinCharge.Concealedwork, includingcutting chasesand making good the walls etc. 15 mm nominal dia Pipes |
| 52 | Providing and placing on terrace (at all floor levels) polyethylene water storage tanksISI:12701marked,withcoverandsuitablelockingarrangementand making necesssary holes for inlet, outlet and overflow pipes but without fittings and bse support for tank. |
| 53 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey combshaftwithbricksandPVC.drainpipe100mmdiameter,1.8mlong complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 54 | Providing and laying Double Flanged (screwed / welded) Centrifugally (Spun) Cast Iron, Class B (IS : 1536) :100 mm dia C.I. Double Flanged Pipe |
| 55 | Providing push-on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and the cost of rubber gasket :100 mm dia pipes |
| 56 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLSPVCinsulatedcopperconductorsinglecorecablein surface/recessedmediumclassPVCconduit,withmodularswitch, modularplate,suitableGIboxandearthingthepointwith1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 57 | Wiring for circuit/sub main wiringalong with earth wire with 2x1.5 sq mm + 1x1.5 sq mm earth wire FRLS PVC insulated copper conducter, single core cable in surface/ recessed 20 mm PVC conduit (Polymer/Polyfit/Anchor/ISI)asrequired.Wireshouldbeof Plaza/Havell\"s/Anchor) |
| 58 | Wiring for circuit/sub main wiringalong with earth wire with 2x4 sq mm + 1x4 sq mm earth wire FRLS PVC insulated copper conducter, single core cable in surface/ recessed PVC conduit (Polymer/Polyfit/Anchor/ISI)as required. Wire should be of Plaza/Havell\"s/Anchor) |
| 59 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing6 pin 5/6 &15/16A modular socket outlet and15/16 A modular switch, connections etc. as required. |
| 60 | Supplying and fixing PVC angle/Batten holder (Anchor/Ambit) including connectionsetc. as required. |
| 61 | Supplying and fixing double Pole 40 Amp, 240 volts, isolator (Havells) in the existing MCB DB complete with connections, testing and commissioning etc as required. |
| 62 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 63 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |