Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-05-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 26-05-2025 |
| 2 | 08-05-2025 | BOQ CORRIGENDUM | BOQ | 19-05-2025 |
| Sl. No. | Item Description |
| 1 | Taking down aluminium windows,chowkats or frames with shutters (without taking off shutters from the frame).incl taking down deco grill and refixing the same after repairing, changing of locks,rubber beading, rollers etc (new aluminium will be measured under item No and new decogrill will be measured under item 9 and 10 respectively |
| 2 | Taking down aluminium/ wooden chowkats or frames with shutters (without taking off shutters from the frame)incl grill not exceeding 1.5 sqm each. and stacking for issued under Sch of Credit. |
| 3 | All as per item No. 2above but exc 1.5 Sqm but n.exc 4 Sqm each |
| 4 | Taking down shutters of any description n exceeding 1 Sqm each complete all as specified & directed |
| 5 | Taking down shutters of any description exceeding 1 Sqm and not exceeding 2 Sqm each complete all as specified & directed |
| 6 | Taking down shutters of any description exceeding 1 Sqm and not exceeding 2 Sqm each and refixing in the same opening after easing, cutting complete all as specified & directed |
| 7 | Taking down aluminium grill with frame/ F/U channel and refixing the same in the same opening |
| 8 | M & L for machine cut cudappah stone slab 20-25 mm thick laid over 15mm thick cement rendering inCM 1:4 as in cills,jambs of window , cooking platform laid and jointed with grey cement slurry mixed with pigments to match the shade of the slab including rubbing and polishing including taking down of old cuddapah stone complete all as specified and directed by the Engineer-in-charge |
| 9 | S & F anodised aluminium section for sliding / openable window / doors of reqd size medium weight section, plain glass on and aluminium wire cloth shutters with two nylon roller on each shutters including star lock handle, soft rubber gasket or aluminium glazing beading fixed with nickel plated screws complete all as specified and directed by Engineer-in-chargeNote(i): Make of AL section shall be Jindalco/Hindalco/Indalco.Glass & wire cloth required shall be measured and paid separately.Note (ii) : The Al section shall be medium weight, section as decided by the Engineer-in-Charge. |
| 10 | S & F Aluminium grill (DG 104) 10 mm thick fixed on aluminium u/F section of suitable size fixed to aluminium window/ventilator. |
| 11 | Supply only aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm & fixed with aluminium wire staples. |
| 12 | Supply and fix in repairs aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm & fixed with aluminium wire staples. |
| 13 | Supply only 4-5 mm thickglass ordinary quality ineach pane for aluminimum slidingwindow complete all as specified & directed by Engineer-in-Charge. |
| 14 | Supply only 5 mm thickfigured glass pin head ineach pane for aluminimum slidingwindow area n exc 0.5sqm in each pane complete all as specified & directed by Engineer-in-Charge. |
| 15 | Hacking out old broken glass (any thickness, size, quality or description) from wooden/aluminiumframes or stone, concrete or brick surrounds, glazed with putty or fixed with beads |
| 16 | S & F4-5 mm thickglass ordinary quality ineach pane for aluminimum slidingwindow complete all as specified & directed by Engineer-in-Charge. |
| 17 | S& f in 4-5 mm thick figured glass pin head ineach pane for aluminimum slidingwindow arean exc 0.5sqm in each pane complete all as specified & directed by Engineer-in-Charge. |
| 18 | S&F as in repairs anodised aluminium alloy curtain rods with fixing brackets,stops,rollers etc all as specified. |
| 19 | Taking down cementor cement lime plaster on brick or stone walls etc including raking out joints, hacking for keys, scrubbing down with water & removing deris outside MD land complete all as specified including necessary scaffolding and safety arrangement |
| 20 | M & L for rendering 12mm thickusing polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratechNote: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provosion of dubbing of the surface and nothing extra shall be payable on this account. The rate also includes the rate of scaffolding and necessary safety measurements |
| 21 | M & L for rendering 5 mm thickusing polymer modified ready mix cement based plaster on the ceiling surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratechNote: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provosion of dubbing of the surface and nothing extra shall be payable on this account. The rate also includes the rate of scaffolding and necessary safety measurements |
| 22 | M&L for15mm(10+5mm)thick in two coats polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratechNote: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provosion of dubbing of the surface and nothing extra shall be payable on this account. The rate also includes the rate of scaffolding and necessary safety measurements |
| 23 | Supply only integrated Water Proofing compound |
| 24 | M&L Preparation of new plastered surfaces of walls and applying first coat of primer, and applying two coat of oil bound distemper. |
| 25 | M&L for complete removal of existing treatment onold decorated surfaces on walls, preparation for distempering and applying first coat of primer, and applying two coat of oil bound distemper. including stopping of nails holes,cracks etc. complete all as specified and directed. |
| 26 | M & L for 3mm wall care putty on walls |
| 27 | M&L for preparing of new plastered or unplastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed by the Engineer-in-charge |
| 28 | Preparation of old surfaces(plastered or unplastered or previously white washed) and applying one coat of white wash on ceiling complete all as specified. |
| 29 | Chipping , Removing,Carefullly Loose Concrete work from structural members (Beams, Columns, Slabb, Chajja etc) by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed by Project Manager. Hard concrete should not be removed by force including removal of debris outside MD land. |
| 30 | Carry out application of ‘Bi-polar migratory corrosion inhibitor\" EPCO-KP-100 on concrete surface. This inhibitor has migratory kind of property which permits the material to migrate to a virtual extent of 100 mm, through pores of concrete, inhibiting the corrosionand de-passivating the Electro-chemical reaction. It has property to attack anode as well as cathode, which is purely alkaline in nature (pH-9.5), so it has no carcinogen activity with concrete |
| 31 | Drilling and fixing Teflon nozzles in RC members, including, Drilling Holes:Drilling 12mm dia, 50 to 100mm deep holes in structural members at the intervals of 300 to 500mm in staggered manner or as directed by the consultants in RC structural element. Cleaning of Holes: Clean the holes by air blower prior to fixing nozzles. Fixing of nozzles: Insert 12mm dia. Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun.Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing.Cure the system for min.12 hrs. Cutting of nozzles: Cut the nozzles by chisel after completion of grouting without damaging structural elements. |
| 32 | Grouting Injecting Super low viscosity epoxy resin by pressure and using injector with accessories till nozzles refused to accept the grout, Including, Mixing of materials: Mixing material components in required quantities as per mfg instruction by weigh batching. Grouting: Fill the grouting gun with material, Maintain desired pressure in the gun by air compressor maintain the pressure at exit (3 to 4 kg/Cm2) by monitoring pressure gauge at exit.Grout the material through prefixed nozzles in the structural elements still its refusal. Seal the nozzle with Non shrinking Epox putty after the refusal. Monitor leakages through other nozzles while grouting and seal them as per requirement |
| 33 | 1)M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. \"Feovert\" of \"Krishna Conchem\" OR \"Roff Rust Cleaner\" of \"Pidilite\" OR \"Shali Rustoff\" of \"STP Ltd\", on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)2)M&L for Anticorrosive Treatment to Reinforcementusing Corroseal - ZR of M/s Krishna Conchem orEpoxy Zinc Primer of M/s. Dr. Fixitby application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat.The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. |
| 34 | M&L for providing CRS TMT bars of 10mm dia and over in various structural RCC elements like columns, beams, Slabs etc. including cutting, bending, fixing of bars with welding/ tying as required at site with & including binding wires etc. and all relevant works like anchoring of the bars in the existing RCC Members including necessary dismantling/taking down of existing rusted & decayed reinforcement complete all as specified and directed. |
| 35 | M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchemas approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete& new concrete by brush application, complete all as specified and directed. |
| 36 | Providing & casting & Repairing of excessively damaged members with Micro-concrete at all levels with all leads & lift or as directed including formwork, centering, scaffolding, & mixing , laying, levelling, and finishing including curing etc. complete (excluding steel reinforcement).for thickness more than 40 mm |
| 37 | Building up the profile of structural members by using polymer modified mortar thickness upto 40mm thickness including leveling profiling etc. complete. Each layer should not have a thickness more than 20 mm with epoxy latex based bond coat before each layer |
| 38 | S&F pressed steell door frame 125x60 mm for doors with one or more rebates including necessary fixing lugs hinges lock strike plates comlete as specified and directed (pcc filling of holloow section measured and paid seprately) |
| 39 | S&F pressed steell door frame 105x60 mm for doors with one or more rebates including necessary fixing lugs hinges lock strike plates comlete as specified and directed (pcc filling of holloow section measured and paid seprately) |
| 40 | M & L PCC typeC-1,1: 3:6 (20mm graded stone aggt) for cills,hold fast filling of hollow of pressed steel door frame etc |
| 41 | S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides and both faces are covered with decorative face veneer with lipping/frame to match complete all as specified and directed by EIC. |
| 42 | S&F 2nd class hardwood 35mm thick glazed and skeleton shutters open and prepared to rceive glass ,gauze etc (withsash bars) edges of plain, chamferred or rounded, fitted with cut and mitred beads for securing gauzes etc, sizes of members of sizes of shutters as specified in SSRpart -I sec 8,cluse 8.24(a). |
| 43 | S&F in repair 18mm thick celuka PVC sheet minimum 600 Kg/Cum density grade 1 quality one side pre-laminated and other side plain white colour to make kitchen cabinet/drawer shutters/cup board shutters fixed with screws, solvent cement/adhesive and parliament hinge as required as per manufacturer instructions complete as per specifications and as directed by the Engineer-in-Charge.Note:- (i) Cup board accessories ie fittings. handles, hinges, will be measured and paid under this schedule.(ii) Quoted rates deem to be include fixing of cabinet on wall with appropriate rawal plug/ dash through fastener (hammer type).(iii) Fabrication and installation of cabinet to be carried out by authorised vendor of manufacturer only. |
| 44 | S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supply and fixing in opening as perspecification given under SSR Part II 2010 including making good the disturbed surface. Make: Rajashree or equivalent. |
| 45 | M&L for factory made solid PVC panel type PVC door shutter 30mm thick consisting of frame madeout of MS tubes for top and bottom rails MS frame shall be covered with moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rails, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent supplying and fixing in the frame at site as per specifications and drawing given under SSR Part II 2004 complete as as specified. Make : Rajashree or equivalent. |
| 46 | S&F MS hold fasts and similar small articles complete all as specified. |
| 47 | M&L for treating with tar or coal tar black paint on back of chowkats area exc 0.10 Sqm but not exc 0.5 Sqm each complete all as specified. |
| 48 | M& L for treating small articles such as stop, covers, gully gratings, hold fasts, and of posts , back of chowkats, etc area not exec 0.1 Sqm each treated with tar or coal tar black paint complete all as specified. |
| 49 | S&F aluminium anodised sliding door bolts with hasp and staple (Bolt type) and fixing clip of lsheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, length of bolt 300mm |
| 50 | S&F in repairs aluminium anodised sliding door bolts with hasp and staple (Bolt type) and fixing clip of lsheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, length of bolt 300mm |
| 51 | S & F stainless steel butt hinges with extruded aluminium alloy with galvanised mile steel hinges pins 100mm size. |
| 52 | S & F in repairs stainless steel butt hinges with extruded aluminium alloy with galvanised mile steel hinges pins 100mm size. |
| 53 | S & F 150 mm extruded aluminium alloy handles, fabricated type anodised. |
| 54 | S & F in repairs 150 mm extruded aluminium alloy handles, fabricated type anodised. |
| 55 | S & F aluminium anodised barrel tower bolt of extruded section of size 200 mm length. |
| 56 | S & F in repairs aluminium anodised barrel tower bolt of extruded section of size 200 mm length. |
| 57 | S & F aluminium anodised barrel tower bolt of extruded section of size 300 mm length. |
| 58 | a) M&L for dismantling completely existing roofing membrane including loosened cement plaster and exposing the top surface of RCC slab and making good the same in CM 1:4including cleaning of all dirts and provide the following water proofing treatment in Accessible Roof & terrace, narrow width over the roof gutter of store houses or chajjas etc. including the debris outside MD land.b)Apply oil boundbitumenprimer @ 0.25 gm/Sqm manufacturerby thesameagency as that of APPwithdensityof 0.87-0-89 Kglitr at 25 c on the prepareddry roofsurface provideand layAPPmodified water proofingmembrancereinforced with nonwoovenpolystermatt with physicalproperties as under :- (aa)Membrane Weight -not less than 3.5 Kg/Sqm (ab)Non woven polyster weight-160 gm /Sqm (ac)Joint Tensile strengthLongiutinal-650 N/SqcmTranverseand longitudnal-350/Sqcm (ad) Tear strengthLongiutinal-300N /cm Tranverse -250N/cm Direction(ae)Impermeability underwater pressure 2Kgf/Sqcmc)APP membraneshallbe laidusing butaretorch by Torchon applicationwith minimum 10cmside overlapand 15cmend lap. Thelaying of membranceshall begot, donethroughan authroiset applicate of Manufacture of membrane.d)S&Fof cool tiles of size 300x300x18-20mm thick over 15mm screed bed in CM 1:4 mixing with linseed oil @3kg/10Sqm set and jointed in neat cement slurry and pointed with epoxy grout complete all as specified and directed by EIC. |
| 59 | i) Dismantling completely existing roof treatment (excluding cement screed bed ) including loosened cement plaster and exposing the top surface of RCC slab and making good the same in CM 1:4 and removing rubbish, etc outside MD land complete all as specified and directed by the Engineer-in-chargeii) M & L for APP modified roof treatment over existing roof slab etc to be executed through approved authorised applicator of the membrane manufacturer with the following specifications complete all as specified and directed:- (a) The wall surface shall be throughly wire brushed cleaned to eliminate all sharp projection, washed dried upto and cleaned overall foreign material and dust to receive primer. (b) The dry surface shall be primed with Torch shield primer as per manufacturer’s instructions, manufactured by the same agency as that of APP membrane.(c) Providing and laying APP modified polyester reinforced water proofing membrane with minimum weight of 3.5 Kg/Sqm, as specified here-in-before.(d) The APP membrane shall be laid using torch-on butane application with minimum 10 cm side overlap and 15 cm end overlap. The laying of membrane shall be got done through an authorised applicator of manufacturer of the membrane.(e) The APP membrane shall be taken up to minimum 200 mm on vertical surfaces. The edge of the membrane shall be fixed with termination bar and fasteners and end shall be properly sealed with sealant.(f) The top of App membrane should be applied two coats of aluminium paint completely all as specified and as directed by Engineer in charge. |
| 60 | M&L for 50mm thick PCC (1:2:4) type B-1, using 20mm graded stone aggregate as in leveling course over RCC roof/ terrace surfaces to achieve required slope, benching etc including making rounded or chamfered on edges mixed with WPC(water proofing compound) as per manufacturer\"s instructions, including demolition of old concrete of any description and removing the debris outside MD land complete all as specified and directed.Note : WPC shall be measured and paid separately as \"supply only\". |
| 61 | M & L 15 mm thick rendering in CM 1:4 over the roof surface complete all as specified and directed |
| 62 | Demolition/Dismantling of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc and removing the debris out side MD land complete all as specified and directed . |
| 63 | M&L for rendering 10mm thick in cement and sand mortar 1:4 finished even & rough for fixing of tiles as in dado or fixing skirting complete all as specified and directed. |
| 64 | M&L screed bed or bedding layer15mm thick for laying floor finishes in cement mortar 1:6 to recive tiles complete all as specified and directed by EIC. |
| 65 | M & L Non Skid ceramic coloured tiles 8 to10 mm thick (square/rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in epoxy grout to match |
| 66 | M&L for coloured glazed ceramic tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed with epoxy grout complete all as specified and directed . |
| 67 | M&L for Non skid coloured ceramic tiles 7mm to 8mm thick ( square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in epoxy grout to match complete all as specified and directed. |
| 68 | M&L for machine cut cudappa stone slab 20 to 25mm thickness over cement screed bed laid and jointed with grey cement slurry mixed with pigments to match the shed of the slab including rubbing and polishing complete all as specified and directed by EIC.. |
| 69 | M&L for 18-20mm thick granite of any type work (Table rubbed and polished) in platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite & Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situation complete all as specified and directed by EIC. |
| 70 | M&L for Kota stone slab 20-25mm thick in Riser/Treads of steps, Landing ,skirting, dado and pillar laid overcementscreed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engr-in-Charge |
| 71 | S&F in repairs wash hand basin of size 550x400mm, vitreous china( flat back) includingbracketsetc complete. |
| 72 | S&F in repairs 20mm bore concealed type fancy CP stop cock, cast copper alloy , screwed down high pressure, screwed for iron pipe or for unions and fixed. |
| 73 | S&F in repairs 20mm bore CP bib taps, cast copper alloy , screwed down, screwed for iron pipe or for brass ferrule and fixed. |
| 74 | S&F in repairs 20mm bore CP pillar taps, cast copper alloyscrewed down high pressure, screwed for iron pipe or for unions and fixed. |
| 75 | S&F in repairs chromium plated shower rose 125mm size for fixing in 20mm dia pipe. |
| 76 | S&F fixed in repairs 15 mm dia Health faucet (ABS Body) mild steel chromium plated suitable for 20 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as speicified and directed by EIC. |
| 77 | S&F in repairs Two way Bib cock with flange 20mm dia approved by the GE complete all as specified and directed by EIC. |
| 78 | Taking down GI tubing and connections including fittings, cleaning for refixing complete all as for following sizes :- |
| 79 | (a) 15mm bore |
| 80 | (b) 20mm bore |
| 81 | (c) 25mm bore |
| 82 | Supplying and laying of 20mm dia CPVC pipes UV stable,leak proof, tough ,rigid , conforming to IS:15778 of SDR 11 standard., medium grade with and including all fittings and fixed to walls and ceilings or laid in floors, complete all as specified and as directed. |
| 83 | S&F GI tubing medium grade galvanised with all fitting and fixed complete to walls and ceiling or laid in floors complete all for the following sizes :- |
| 84 | (a) 20mm bore |
| 85 | (b) 25 mm bore |
| 86 | Dismantling of cast iron pipe 100 mm dia including all fittings |
| 87 | (a) 100 mm dia |
| 88 | (b)75 mm dia |
| 89 | S&F inPVC (SWR) pipes, single socketed, in any length with rubber ring joints fixed to walls/floor with proper brackets complete all as specified and directed by the Engineer-in-charge for the following bores: |
| 90 | (i) 75mm bore |
| 91 | (ii) 110mm bore |
| 92 | S&F as in repairs for 100mm bore PVC (SWR) branch piece, single (single \"Y\") equal or unequal and fixed complete all as specified and directed by the Engineer-in-charge |
| 93 | S&F as in repairs for 75mm borePVC (SWR) branch piece, double (double \"Y\") equal or unequal and fixed complete all as specified and directed by the Engineer-in-charge |
| 94 | S&F as in repairs for PVC SWR bends with/without oval access door(any radius) complete all as specified and directed by the Engineer-in-charge for the following bores: |
| 95 | (i) 75mm bore |
| 96 | (ii) 110mm bore |
| 97 | S&F as in repairs for PVC SWR vent cowl complete all as specified and directed by the Engineer-in-charge for the following bores: |
| 98 | (i) 75mm bore |
| 99 | (ii) 110mm bore |
| 100 | S&F as in repairs for sinks made of stainless steel 1mm thick kitchen or laboratory with plugs,washers and wastes including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting unions to pipe, overall size 495mmx420mm bowl size 410mmx330mmx160mm complete all as specified and as directed. |
| 101 | S&F in repairs vitreous white China Europeon water closet (Pedestal Pattern)including seat cover with mild steel chromium plated or aluminised hinging devices complete all as specified and directed by EIC. |
| 102 | S&Fin repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers |
| 103 | S & F in repairs Soap dish, vitreous China white, approximate size 160x 160x90mm fixed to chromium plated brass screws |
| 104 | S&F in repairs chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges |
| 105 | S & F in repairs 20/25 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed |
| 106 | Taking down PVC/Cl flushing cistern including mild steel brackets , S&F 10 ltr capacity high level/low levelPVC cistern with PVC flush pipe brackets connections and making good the surfaces complete . |
| 107 | Demolition of cement concrete (unreinforced) of any descriptionand in any position not otherwise specifically provided for and removing the debris out side Md land complete all as specified and directed by EIC |
| 108 | M&L for PVC floor trap 75 mm dia of out letwith grating including jointing to waste pipe with solvent cement fixed in cement concrete type B1 1:2:4 mixed with WPC including taking down the old one etc complete all as specified and directed. |
| 109 | M&L for cement concrete type E-2,1:5:10 (using 40 mm graded aggregate) as in sunken portion of toilet and bathroom complete all as specified and directed. |
| 110 | M&L for PCC 1:2:4 type B-2 using 40mm graded stone aggregate mixed with water proofing compound @ 2% by weight of cement in position complete allas specified. |
| 111 | M & L for special treatment for sunken portion of WC bath toilet kitchen etc executed in following stagesstage 1 providing 20 mm thick plaster in CM 1:3 mixed with water proofing chemical of Dr fixit or shalicrete R of STP ltd in the proportion/quantity all as per manufacturers instructionsstage 2 Application of 1 st coat of tarfelt LM of STP Ltd (diluted with water in ratio 1:1) @ 250 gms/sqm and apply the primer on the plastered surfacesStage 3 Application of 1 st coat of tarfelt LM of STP Ltd (without dilution with water) @ 1kg/sqm by brush all as per manufacturers instructions.Stage 4 Laying fibre glass cloth ( weight not less than 50 gm/sqm) over 1 st coat while the coated surface is still stickyStage 5 After 6 to 7 hours iterval, apply second coat ie final coat of tarflet LM of STP ltd (without dilution with water) @ 1 kg/sqm by brush as per manufacturers instructions.Stage 6 Providing 10 mm thick protective plaster in CM 1:3 mixed with STP No. 1 @ 250 ml/50Kgcement all as per manufacturer\"s instructions.Stage 7 Carry out ponding test for 72 hours to ensure water tightness of repaired sunken portion.Notes: (i) Mode of measurement: Actual area treated (floor and adjoining walls) will be measured and paid. |
| 112 | S & F in repairs PVC connection 20mm size with PTMT nut of length 450 mm complete all as specified and directed by Engineer in charge. |
| 113 | S & F in repairs 40 mm bore PVC pipes single socketed in any length jointed and fixed to walls and floors for spouts, washbasin outlet |
| 114 | M&L for demolition of reinforced cement concrete in roofs, floors, beams, staircases, landings, chajjas, water tanks and similar suspended work (reinforcement cut to facilitate demolition) |
| 115 | M&L for 75mm thick cement concrete type C-2,1:3:6 (40mm graded stone aggregate) as in plinth protection ,finishing cement concrete surface even and smooth without using extra cement and spike rollong to surfaces or making impression of expanded metal,whilst the concrete is green including necessary dummy joints @1.5m spacing and filling with bitumen & necessary form work complete all as specified and directed. |
| 116 | S & F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 117 | S & F Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel , flat sections or tubes) including distance pieces, cleats etc. |
| 118 | M & L synthetic enamel painting to new steel surfaces of any description over 10 CM width or girth in two coats over a coat of primer including preparation of surface. |
| 119 | M & L synthetic enamel painting to old steel surfaces of any description over 10 CM width or girth in one coats over a coat of primer including preparation of surface. |
| 120 | M & L in repairs for 18/19 mm plywood grade BWR type BB fixed with screws to timber frame work |
| 121 | Demolition of brickwork of stone/boulder masonry, build in cementmortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles and removal of debris outside MD land conplete all as specified. |
| 122 | Providing and injecting chemical emulsion for post antitermite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron. |
| 123 | Treatment of soil under existing floors using emulsion @ one litre per litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floors |
| 124 | Antitermite treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ .5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same |
| 125 | M & L for Brickwork with subclass `B\" bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed by EIC. |
| 126 | Complete removal of existing treatment of walls, chajjas, beams, parapets etc by brooming down or steel wire brushing, scraping down moulds, moss and greasy spots etc including washing down with water etc and filling cracks above 5 mm thickness with mortar using pidicrete URP of Dr fixit or equivalent of M/s STP Ltd, filling cracks less than 5 mm withCrack X paste of M/s Dr fixit or equivalent of M/s STP Ltd |
| 127 | M&L for leakage / seepage proof coating consisting of preparing the newly plasteredsurfaces of existing exterior walls, parapet walls, chajjas etc. and applying Primeseal primer of M/s Dr Fixit or equivalent chemical of M/s STP Ltdas approved by the GE or one coat of Chemstic PDE 600 elastomeric coating (and allowing to dry for 8hrs) under torch dry condition and subsequently applying two coats of water proofing decorative elastomeric coating system Raincoat of M/s Dr Fixit with DFT 100microns or Shalicryl 215 of M/s STP Ltd or Chemstic PDE 600 elastomeric coating (the surfaces after painting one coat shall be allowed to dry for 6 to 8hours before application of next coat) including necessary scaffolding etc, complete all as per manufacturer instructions, as specified & directed.Note:The aforesaid treatment shall be got executed by the contractor from the authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE. |
| 128 | M & L for cement concrete 1:2:4 , type B-1 (using 20mmgraded stone aggregate) as in coping, bed block,including necessary form work. |
| 129 | Fixing only Rotational moulded polyethylene water storage tanks of capacity 500Ltr (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I Note:- PVC water tank of 500 litre capacity shall be supplied by MES store. |
| 130 | S&F 25mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20mm-210gms./ 25mm-455gms/ 40mm - 690 gms) complete all as specified and directed by EIC. |
| 131 | M& LPre Polished Chequredcement concrete tiles 30cmx 30 cm x 20 mm thick, set, jointed and pointed in near cement slurry in floors with mixture of grey white cement in equal proportions complete all as specified and as directedMake :- Gems / Orient/ Nitco/ Ntc or equivelent |
| 132 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting in any girth in brick walls or stone concrete block or slab walls complete all as specified and directed by EIC. |
| 133 | M&L as in repairs to reinforced concrete pipe class NP 2 laid and jointed complete with collars 150 mm dia |
| 134 | M & L for plain cement concrete 1:3:6 type C2 as in bed to drain pipe, 150mm bore including packing under and haunching against the sides of pipes after they are laid and testedincluding necessary shuttering and supports to concrete |
| 135 | Taking down carefully point wiring of any type & pattern (Light/Fan/Socket or power) including fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings of any type etcand making good disturbed surfaces of walls/ roof etc, complete all as specified and directed. |
| 136 | Taking down complete main switches/DBs with enclosure and its components of any size and capacity ,etc complete all as specified and directed. |
| 137 | M & L for Concealed point wiring complete with proper colour coding using, 1100 Volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked drawnin and including PVC conduit (minimum 25mm dia)with all accessories, fittings, PVC junction boxes etc, with suitabe sunk pressed steel boxes not less than 2 mm thick, also including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for one light point /fan/bell point controlled by one one way switch, complete all as specified and directed.Make of conduit :- Sudhakar/ Precision/ PressfitMake of wire :- Finolex/ Havells/ Polycab/ KEI/Benlo |
| 138 | All as per item No. 124 above but for One 2pin/3 pin socket outlet 5 Amps on same board complete all as specified and directed. Make: Anchor/ Havells (Crabtree) / Bentec |
| 139 | All as per item No. 124above but for One 2 pin/3 pin socket outlet 5 Amps on independent board.Make: Anchor/ Havells (Crabtree) / Bentec |
| 140 | M&L for Concealed point wiring using proper colour coding with 1100 Volts grade, 2.5 Sqmm PVC insulated, FRLS, unsheathed, wire confirming to IS-694, Part-II, ISI marked with multistranded copper conductordrawnin and including PVC conduit (minimum 25mm in dia)with all accessories, fittings, PVC junction boxes etc, with suitable sunk pressed steel terminal box not less than 2 mm thick, also including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, multistranded, copper conductor 1100 Volts grade, green color, continuous earth wire connected to common earth dolly for 15 Amps, 3 Pin, socket outlet independent complete all as specified and directed. Make of conduit :- Sudhakar/ Precision/ PressfitMake of wire :- Finolex/ Havells/ Polycab/ KEI/Benlo |
| 141 | S&F modular type6A one way SP switch 1 moduleconfirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed. Make: Anchor/ Havells (Crabtree) / Bentec |
| 142 | S&F modular type 2/3 pin combined shuttered type 6 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed.Make: Anchor/ Havells (Crabtree) / Bentec |
| 143 | S&F modular type 2/3 pin combined shuttered typr 16 Amps socket 2 module conforming toIS: 1293-2005 complete all as specified and directed.Make: Anchor/ Havells (Crabtree) / Bentec |
| 144 | S&F modular type16 A one way SP switch 1 module confirming to IS: 3854-1997 with finguer proof terminal complete all as specified and directed. Make: Anchor/ Havells (Crabtree) / Bentec |
| 145 | Supply & Fix Modular Bell push flush type 6 Amp, 1 module, 230 Volts complete all as specified and directed.Make: Anchor/ Havells (Crabtree) / Bentec |
| 146 | Supply and fix bell ding dong AC 230 V single pole.complete all as specified and directed.Make: Anchor/ Havells/ Maru |
| 147 | S & F Modular Blank plate 1 module suitable for Modular switch boards all as specified and as directed |
| 148 | S & F Modularcover plate 8 modules |
| 149 | S & F Modular metal flush box with modular cover plate 4 modules |
| 150 | S & F Modular metal flush box with modular cover plate 3 modules |
| 151 | S & F Modular metal flush box with modular cover plate 2 modules |
| 152 | S & F Modular metal flush box with modular cover plate 1 module |
| 153 | S&F ceiling rose three terminal, 230 Volts PVC / Polycarbonate body, complete all as specified and directed. Make: Anchor/ Havells/ Vinay |
| 154 | S&Fmodular type 120W step fan regulator of 2 module size conformng to IS: 11037-1984 complete all as specified and directed.Make: Anchor/ Havells (Crabtree) / Bentec |
| 155 | S&F in repairs Surface, hanging and wall mounted batten (Double side connection) suitablefor LED tube 20/22 watts, operating on 230 volts alongwith tube rod 4 feet long 22 watt (double side connection), driverincluding fixing mounting blocks 2 Nos, 15 mm MS conduit, 1.5 sqmm 3 core pvc insulated copper conductor cable including fixing arrangements complete all as specified and directedMake : Bajaj, Model No : BCLAV20W-LEDP, Halonix:-: HLB-03-18-CW-AL-SQ-HL2, Jaquar-: LGLZU1X022XC, Wipro :-Note : The lowest tenderer shall furnish 3 years warranty certificate from OEM for luminiries including LM79 & LM80 test certificate from NABL certified laboratory. |
| 156 | Supply and fixing in replacement of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt opearating on 220 V AC decorative type with driver holder and LED lamp including provision with three core flexible copper conductor cable of suitable size and PVC square blocks complete all as specified and directed Make : Bajaj, Model No : BCLAV10W-LEDP, Halonix:-: HLB-03-18-CW-AL-SQ-HL2, Jaquar-: LGLZU1X010XC, Wipro :-Note : The lowest tenderer shall furnish 3 years warranty certificate from OEM for luminiries including LM79 & LM80 test certificate from NABL certified laboratory. |
| 157 | Taking down of existing ceiling fans and re-fixing of the same ceiling fan 1200mm sweep including provision of cable from ceiling nose/ conductor to fan and spray painting of ceiling fan with two coats of synthetic enamel paint, after preparation of surfaces, complete all as specified and directed. |
| 158 | Supply & fix Heavy Duty metallic Exhaust fan high speed type of sweep 300 mm, speed 1400 RPM, air delivery 1300CMH, power 70W (approx) comprising of double ball bearing, blades,louvers complete mounting anchor fasteners, aluminium louvers made of aluminium sheet of 0.5 mm thickness, provision of three core 1.5 Sqmm PVC insulated copper cable from ceiling rose to fan etc complete all as specified and directed.Make-:Crompton/ Orient/ Almonard/ BajajNote -: The Contractor shall submit 1 years warranty certificate from OEM of exhaust fan. |
| 159 | S & F MCB DB, 12 way, SPN, double door, 240 Voltsand including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections complete all as specified and directed.Make: Schneider/Legrand/Havells/Indoasian/BentecNote: Quoted rate shall be deemed to include for provision of copper bus bar of 200 Amps rating. |
| 160 | S & F MCB SPN 40 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacityMake: Schneider/Legrand/Havells/Indoasian/Bentec |
| 161 | S & F MCB SP 5 to 32 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacityMake: Schneider/Legrand/Havells/Indoasian/Bentec |
| 162 | M&L for sub mainwiring with twosingle core 6.0 Sqmm PVC insulated FRLS multistrandedflexible copperconductorcable 660/1100 volts grade downin throughnon metalicPVC casing capingwith and includingPVC insulated 6 Sqmmsinglecore singlestrand copperconductoras continous earth wire in greencolour connected to commonearth dolly all as specified and as directedNote : 1.Two runs ofcable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit.Make of wire :- Finolex/ Havells/ Polycab/ KEI/BenloMake of casing capping: Pressfit/ Precision/ Anchor |
| 163 | M&L for sub mainwiring with twosingle core 1.5 Sqmm PVC insulated FRLS multistrandedflexible copperconductorcable 660/1100 volts grade downin throughnon metalicPVC conduitwith and includingPVC insulated 1.5 Sqmmsinglecore singlestrand copperconductoras continous earth wire in greencolour connected to commonearth dolly all as specified and as directedNote : 1.Two runs ofcable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit.Make of wire :- Finolex/ Havells/ Polycab/ KEI/BenloMake of casing capping: Pressfit/ Precision/ Anchor |
| 164 | S&F in repair/replacement of building Security lightfitting 30/35 Watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements and taking down old rusted bracket fittings completeall as per directed by Engr- in – charge.Make: Wipro/ Bajaj/ Crompton/ Jaquar |
| 165 | Supply install, test and commissioning of Powder coated LTFeeder panel cubical out door type Channel mounted compartmentalized in construction allConfirming to IS 8623 Part 1 1993CPRI approved factory fabricatedmade out of 3 mm thick CRCA sheet & suitable size to accomodate all accessories / fittings, to accommodate incoming MCCB and TPN Copper bus bars, incomer MCCB and outgoing MCCB, MCB, ContactorsThe TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The bus bar shall have copper extension links for connecting with out going MCCB. Thecubicle shallhaveabottomchannel & free standing frame made of angle iron of size not less than 40mm X 40mm X 6mm of A detachable predrilled gland plateof thickness not less than 3 mm thickpowder coated should be used at thebottom for entry of armoured cableof adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side. The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs, control wiring by 1.5Sqmm Wireand consisting the following, including taking down of old unsv panel after disconnecting Existing cables, Existing energy meters and re fixing the energy meters at new panel & Reconnecting the cables to new panels and including PCC foundation, excevation, grouting bolts.: Location SPDC P-12a) Copper bus bar 150 Amps for 3 phase and Neutralb) MCCB TP 100 Amps 415 Volt25 KA - 1 Noc) MCB TPN 40 Amps, 25 KA 415 Volts- 1 No (Security light & staircase light)d) MCB SPN 40 Amps, 10 KA 230 Volts - 10 Nose) MCB SPN 20 Amps, 10 KA 230 Volts - 02 Nosf) Digital Ameter -01 No,f) Digital Volt Meter - 01 Nog) Digital type ISI marked energy meter 1 Øhaving range 10-60 Amps - 11 Nos Make: HPL/ L&T/ Benlo h) LED based phase indication lamps RYB - 1 Set |
| 166 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 167 | M & L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised MS strip 32 x 6 mm by means of bolts, nuts, check nuts and washers all as shown in Electrical Plate No.3 connected to earthing test point all as specified or indicated including testing on completion. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy