| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to stores and rubbish off the premises. all as directed. |
| 2 | Roughening surfaces of old concrete floor by picking, sweeping, clean and washing down with water to remove dust, etc, all as specified and directed. |
| 3 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/ blankets, any thickness including cover fillets complete all as specified. |
| 4 | M&L 25mm thick cement concrete type B0, 1:2:4, (using 12.5 mm graded aggregate) as in sub base for floor complete all as specified and directed . |
| 5 | Material and labour for screed bed or bedding layers of 15 mm thick cement mortar (1:4) for laying floor finishes all as specified and directed |
| 6 | Material and labour for screed bed or bedding layers 10 mm thick cement mortar (1:3) to receive tiles in vertical surfaces all as directed all as specified and directed. |
| 7 | M&L Vitrified ceramic tiles light shade double charged of 10 mm thick (Square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.28 sqm in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified. |
| 8 | All as per item No 7, here-in-before but as in skirting on vertical surfaces. |
| 9 | M&L Vitrified ceramic tiles light shade of 10 mm thick (Square/ rectangular) polished, area of each tiles not exceeding 0.36 sqmin floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified. |
| 10 | All as per item No 9, here-in-before but as in skirting on vertical surfaces. |
| 11 | M&L for glazed ceramic coloured tiles of size 350x250x 7mm/450x 300 x 7 mm thick as on vertical surfaces such as wall, dado ,skirting etc set and jointed in neat cement slurry and pointed with coloured cement to match complete all as specified. |
| 12 | M&L anodised aluminium snap grid with powder coated frame work for false ceiling of size 605x605 mm including 6mm dia GI (upto 1200mm length) hangers adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size60 mm long and expansion hold fasteners 12.5mm dia 40 mm long complete all as specified. |
| 13 | M&L 4mmnon asbestos fibre cement building boards flat, fixed or laid/inserted to timber/GI/aluminium frame work with screws complete and applying two coats of Oil bound distemper over a coat of primer complete all as specified. |
| 14 | S&F Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing atsite on PVC frame as per specifications and drawing complete all as specified and directed. |
| 15 | S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed. |
| 16 | S&F for Framed work such as grills, gratings etc, with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0, and for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. all as specified. |
| 17 | M&L welded steel wire fabric, weight n exc 4 kg per square meter complete , fixed to steel members, all as specified and directed. |
| 18 | Cutting holes in brick walls in cement mortar for inserting holdfast or pipes and making gooddismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required exc half brick but not exc one brick, etc complete all as specified and directed. |
| 19 | M&L for preparation of new steel and iron surfaces of any description, over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed . |
| 20 | M & L for preparation of surfaces of walls and applying two coat of Oil Bound Distemper over a coat of alkali resistant primer and 1 mm thick wall care putty after complete removal of existing treatment, all as specified and directed. |
| 21 | Material and labour for applying one coat of white wash on old decorated surfaces of ceiling and cornices including preparation of old plastered or un plastered surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots all as specified and directed. |
| 22 | M&L for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 23 | All as per item No 22 but on steel surfaces |
| 24 | Taking down easing and adjusting aluminium shutters/partitions including rubber neoprene packing complete of any description n.exc 1 sqm each andrefixing in same opening or other openings, all as specified and as directed. Note :- Replacement of door closer, glass, lock, handle, tower bolt etc shall be measured and paid separately. |
| 25 | All as per items 24, here-in-before, but exc 1 sqm and n.exc 2 sqm each refixing in same opening or other openings. |
| 26 | Hacking out old broken glass (any thickness size quality or description) from metal framesincluding punching or drilling out old glazing pins/spring clips and providing and fixing new ones., all as specified and as directed. |
| 27 | M&L 12 mm thick Toughned glass as in hinged doors, partitions, windows, automaticdoors and similar work including cutting to shape, drilling holes with handles, locks, hinges, etc complete fittings arrangement as required, all as specified and directed |
| 28 | M&L for sheet glass 4.80mm thick ordinary quality obscured or frosted on one side and glazing with oil putty in square exec 0.5 Sqm in each pane complete all as specified and as directed. |
| 29 | M&L solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers, all as specified and directed. |
| 30 | M&L for providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) for any sunk or raised moulding to flat surface over metal frame work and reinforced with GI wire mesh with complete arrangements including cornices, pattern/design etc all as specified and directed. |
| 31 | M&L for preparation of new surfaces and applying two coats of OBD over alkali resistant primer after applying 2 mm thick wall care putty on ceilings, all as specified and directed. |
| 32 | Material and labour preparation of old decorated surfaces including washing, rubbing down and stopping of distempered surfaces and applying one coat of distemper oil emulsion on walls all as specified and directed. |
| 33 | Allas per item No 32 above but on ceiling. |
| 34 | S&F Suspended metal grid Ceiling System with mineral fibre acoustic tiles as per following specifications:-a) Ceiling Tiles:- Mineral fibre acoustic tile of 16mm thickness having sand textured finish with acoustical punchers, bevelled regular edge and 8mm drop in module size of 600 x 600mm. Tiles shall have humidity resistance (RH) of 99%, NRC 0.50 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 33db as per ASTM E1414, Light Reflectance ≥85% as per ASTM E-1477, Thermal Conductivity k = 0.052 - 0.057 W/mK, Colour Global White, Fire Performance of class 0/1 as per BS 476 Part 6/7 and Class A as per ASTM E84.b) Metal Grid:- The grid system shall be 15 mm wide T - section flanges colour global white (matching to tile colour) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam\". All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of morethan 100kg. |
| 35 | The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. The ceiling grid sections shall be fixed to ceiling with 6 mm dia GI hangers upto required length by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5mm dia 40 mm long, complete all as directed.MAKE OF CEILING GRID : ARMSTRONG, Model: SUPRAFINE 38 or equivalent in GYPROC / USG BORAL / UNISTEEL, MAKE OF CEILING TILES: ARMSTRONG, Model: DUNE or equivalent item in GYPROC / USG BORAL / U TONE) |
| 36 | Taking down aluminum frame with shutters of any description exc 1.50 sqm but n.exc 4.0 sqm each, complete all as specified. |
| 37 | M&L for brick work with fly ash brick straight or curved on plan exc 6.0 mtr mean radius built in 1:6 cement mortar complete all as directed. |
| 38 | M&L rendering 15 mm thick on fair faces of brick work/concrete surfaces in CM 1:6, finished fair & even & smooth without using extra cement, all as specified and directed. |
| 39 | S&F powder coated aluminum frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified. |
| 40 | S&F powder coated aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws, etc. complete all as specified. |
| 41 | S&F Pre-laminated 9 mm thick particle board interior grade prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to frame work complete all as specified. |
| 42 | Supply and fixed aluminium (die cast) body door closer hydraulically regulated designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and as directed. |
| 43 | M&L for preparation of new surfaces and applying two coats of OBD over alkali resistant primer after applying 2 mm thick wall care putty on walls, all as specified and directed. |
| 44 | S&F for Framed work such as grills, gratings etc, with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0, etc complete all as specified. |
| 45 | S&F for expanded metal, cut to length, bent to shape, required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples, weight not exceeding 4 Kg/Sqm, complete fixed to steel members, all as specified and directed. |
| 46 | Material and labour for providing Cement Concrete (1:2:4) type B1 using 20 mm graded aggregate as in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, coping, kneelers, apex stones etc water troughs and the like including weathering, slightly rounded or chamfered angles and throating, all as specified and directed. |
| 47 | Disconnecting existing water tanks exc 500 & n.exc 1000 ltr of capacity, setting aside (or lowering if required) for repairs, etc and hoisting if required re-connecting and re-fixing in position after cleaning and removing all scale and dirt etc from tank and from mouths of circulating pipes etc all as specified. |
| 48 | All as per item No 46 above but exc 1000 ltr &n.exc 2000 ltr of capacity. |
| 49 | Supply, hosting and fix 1000 litres rotational moulded polythene water storage water tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I (ISI marked) all as specified and directed. |
| 50 | All as per item No 48 above but2000 ltr of capacity. |
| 51 | Supply and fix as in repairs, ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for 25mm bore pipe and fixed (Minimum weight 455 gms) all as specified and directed. |
| 52 | Taking up or down 20 mm bore steel tubing and including cleaning for refixing or removal to store complete all as directed. |
| 53 | All as per item No 51 above but 25mm bore of pipes. |
| 54 | Supply, lay and fix 20 mm bore galvanized iron water tubing medium grade including all fittings and fixed complete to walls and ceiling or laid in floors. all as specified and directed. |
| 55 | All as item No 53 above but fixing only. |
| 56 | Supply, lay and fix 25 mm bore galvanized iron water tubing medium grade including all fittings and fixed complete to walls and ceiling or laid in floors. all as specified and directed. |
| 57 | All as item No 55 above but fixing only. |
| 58 | Supply and fix gun-metal, globe or gate valves with iron wheel head, screwed both ends for 20 mm fbore iron pipe all as specified and directed. |
| 59 | All as per item No 57 above but 25mm bore. |
| 60 | M&L providing precast cement concrete type B1 1:2:4 (20 mm graded stone aggregate), solid building blocks or slabs 10 cm thick with set in cement mortar 1:4 complete in walls, all as specified and directed. |
| 61 | M&L for mild steel TMT bars10 mm dia and over, cut to length, bent to shape required, including cranking bending spirally for lintels and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, all as specified. |
| 62 | Material and labour for providing Precast Reinforced Cement Concrete(1:2:4) type B1 using 20 mm graded aggregate as in cover slabs set in cement mortar (1:4) including necessaryform work all as specified and directed. |
| 63 | Taking down cement plaster, of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water all as directed. |
| 64 | M&L rendering 15 mm thick on fair faces of brick work/concrete surfaces in CM 1:4 on walls, finished even and smooth without using extra cement, all as specified. |
| 65 | M&L for preparation of new surfaces and applying two coats of cement based paint on walls over a coat of primer, all as specified and directed. |
| 66 | Taking down chowkats or frames not exc 1.5 sqm each but with shutters (without taking off shutters from the frame), all as directed. |
| 67 | All as per item No 65 but exc 1.5 sqm but n.exe 4sqm each. |
| 68 | Supplying and installing uPVC- Sliding windows/doors made out of lead free green profiles having a worldwide presencewith a GREENLINE mark having two tracks and two sashes (shutters) and one fly screen sash with frame dimension of 88mm x 49mm and sash dimension of 61mm x 47mm x 37 mm and flyscreen sash dimension of 32mm x 58mm with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm. The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The profile manufacturer should be a certified member of IGBC and should have extrusion facility in India and the windows to be assembled and installed by an authorised fabrication partner . The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets, bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent. The profiles should be of an international brand having factories in multiple countries and having a warranty of 20 years. The profiles should conform to BSI Quality Management System ISO 9001-2015 and Environmental Management System ISO 14001-2015 (without glass/ mesh). |
| 69 | Supplying and installing ofuPVC- Sliding windows /doors made out of lead free green profileshaving a worldwide presence with a GREENLINE mark having three tracks and three sashes with fly mesh (shutters) with frame dimension of 137.5mm x 49mm and sash dimension of 61mm x 47mm x 37mm and fly screen sash dimension of 32mm x 58mm each with with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm. The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The profile manufacturer should be a certified member of IGBC and should have extrusion facility in India and the windows to be assembled and installed by an authorised fabrication partner . The windows must be installed complete with all kinds of ironmongery in Ist quality (including EPDM gaskets, bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside and Outside with Make: Dowcorning / GE or equivalent.The profiles should be of an international brand having factories in multiple countries and having a warranty of 20 years. The profiles should conform to BSI Quality Management System ISO 9001-2015 and Environmental Management System ISO 14001-2015 with and including necessary scaffolding as required for fixing, complete all as specified and directed. Make: Kommerling or Fanesta or equivalent other approved makes as specified in particular specifications |
| 70 | Supplying and installing rectangular uPVC louver windows with fixed and exhaust made out of lead free green profiles having a worldwide presence with a GREENLINE mark with frame dimension of 58mm x 36mm for windows with aluminium powder coated framework and glass blades for louvers with corners fusion welded, fully reinforced with Galvanized steel of 1.2mm . The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The profile manufacturer should be a certified member of IGBC and should have extrusion facility in India and the windows to be assembled and installed by an authorised local fabrication partner . The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets, bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside and Outside of Dowcorning / GE or equivalent. Scaffolding if required will be charged at actuals. The profiles should be of an international brand having factories in multiple countries and having a warranty of 20 years. The profiles should conform to BSI Quality Management System ISO 9001-2015 and Environmental Management System ISO 14001-2015 and also scaffolding if required for fixing is deemed to include in the rate quoted of Make Kommerling or equivalent model in Fanesta & in other makes. |
| 71 | M&L 5 mm thick Toughned glass as in hinged doors, partitions, windows, automaticdoors and similar work including cutting to shape, drilling holes required, complete all as specified. |
| 72 | S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, all as specified. |
| 73 | Forming jambs etc to openings (to foregoing item) including cutting, toothing and properly bonding into old work, also facing jointing and pointingto match existing work in cement mortar 1:4 complete all as specified and directed. |
| 74 | Making good under cills or over arches, lintels and bressumers, including all pinning when necessary in cement mortar 1:4 complete all as specified and directed. |
| 75 | (E/M PORTION)Materials and Labour for surface type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing capping medium duty complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. |
| 76 | One 3 pin socket outlet, 5 Amp independent |
| 77 | Supply & fixingwall mountedfans 230 volts singlephaseoscillating 400 mm sweep with white/Black Color with following technical specification Box Dimension 48x24.5x47.5cm wattage 35W ,Air Delivery (CMM)76 Blade Length 40CM,Speed 1500RPM, Item Weight 4.2Kg Voltage 165-285V, Blade Material ABS PLastic including all Fixing accessories for fixing at Wall complete all as specified and directed by Engr-in-Charge. |
| 78 | S&F Ceiling rosethree terminals polycarbonate , isolated body completeall as specified and directed. |
| 79 | M & L for sub main wiring with 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through and including PVC casing-capping of suitable size, surface type all as directed. |
| 80 | S & F Switch socket combination with back cover 2 in 1, 5 Amp flush type complete all as specified and directed. |
| 81 | S & F Ceiling rose, 3 terminal PVC insulated body completeall as specified and directed. |
| 82 | Supply and fixing PVC casing/capping of size 25 mm with all accessories all as directed . |
| 83 | Supply and fixing PVC casing/capping of size 20 mm with all accessories all as directed . |
| 84 | S & F Sheet metal enclosure for MCB DB double door 240V single pole & Neutral 8 way with common bus bar complete all as specified and directed. |
| 85 | S & F MCB \"C\" series single pole 5 to 32 Amps, breaking capacity 10KA. complete all as specified and directed. Make : Cat No. 408587, ofLegrand or equivalent make specified in tender. |
| 86 | Note: Schedule of credit (SCHEDULE OF CREDIT)amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ. |