| 1 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as reqd. |
| 2 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as reqd. |
| 3 | Providing and laying earth connection from earth eletrode with 6 SWG dia G.I. wire in 15mm dia G,I, pipe from earth electrode including connection with G.I. thimble excavation and re-filling as reqd. |
| 4 | Supplying and fixing following size modules GI box along with modular base and cover plate for modular switches in recess etc as reqd |
| 5 | 1 or 2 Module |
| 6 | 3 Module |
| 7 | 6 module |
| 8 | 8 Module |
| 9 | 12 Module |
| 10 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Group B |
| 11 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box i/c connections but excluding modular plate etc. as reqd. |
| 12 | 5 amps switch |
| 13 | 5 amps socket |
| 14 | 15 amps switch |
| 15 | 15 amps socket |
| 16 | Bell Push |
| 17 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 18 | Supplying and fixing suitable size GI box wuth modular plate and cover in front or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SPMCB . \"C\" curve including connections , painting etc as reqd |
| 19 | Suppling and fixing suitable sie GI Box modular Plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16 A modular switch, connection etc. as reqd |
| 20 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.Group B |
| 21 | Supplying and fixing Brass batten/angle holder including connection etc as reqd |
| 22 | Supplying and fixing 3 pin . 5 amp ceiling rose on the existing junction box/wooden block including connections etc as reqd |
| 23 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required |
| 24 | 1X1.5 sq.mm |
| 25 | 2x2.5 sq.mm |
| 26 | 2x4 sq,mm |
| 27 | Supplying and fixing of following sizes of Heavy duty class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 28 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Heavy dutyclass PVC conduit as required.2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 29 | Supplying and fixing call bell/buzzer suitable for single phase , 230 Volts complete as reqd |
| 30 | Supply, installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Moter, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. conopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as reqd. |
| 31 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator) |
| 32 | 12 way double door |
| 33 | 8 way double door |
| 34 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
| 35 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps |
| 36 | S/F of Single box type fitting(1x20 watt) complete with all accessories i/c 1 No. 20 watt LED tubeetc. directly on ceiling or wall i/c connection testing etc. as reqd.(PhilipsModelTMC 502 1xT - LED 22W) (MAS LED) |
| 37 | S/F ofDouble box type fitting(2x20 watt) complete with all accessories i/c 2 Nos. 20 watt LED tubeetc. directly on ceiling or wall i/c connection testing etc. as reqd.(PhilipsModelTMC 502 2xT - LED 22W) (MAS LED) |
| 38 | Suplying & fixing of following type steet lights fitting luminaire with efficacy 100 lumen/watt , pressure dia cast aluminium and heat resistance toughened flat glass complete with accessories having IP 65 protection with against dust and water & replaceable driver with 4 KV surge protectioni/c making connections etc as reqd.(make Philips) |
| 39 | 70 watts (BRP032 P LED 75CW) |
| 40 | 150 watts (Model BRP340 LED 175CW) |
| 41 | Supplying,fixing and laying of one number PVC insulated and PVC sheathed/XLPEaluminiumconductor, armoured power cable confirming to 1.1KV grade of following size direct in ground including excavation,sand cushioning, protective covering, refilling the same etc as reqd. |
| 42 | 4x16 sq.mm |
| 43 | 3x6 sq.mm |
| 44 | S/F 3x2.5 sq mm PVC sheathed copper conductor flexible wirei/c connection etc as required |
| 45 | S/I/T/C of 150 watts LED flood light fitting 5700K pressured die cast housing with IP 65 protection efficient high 220V- 40V output emitter LED for better distribution with dimension 447x163x327 mm and colour 6500 with lumens 17200 with all accessories etc. as required at site. (Model No. BVP122 LED 147 CW AK55 FG PSU A1) (Philips Make) |
| 46 | Supplying and fixing of 40mm HDPEPipe i/c excavation of CC roadand making good the same etc. ad reqd. (Rex, Finolex and Jindal) |
| 47 | Servicing / cleaning the panel/feeder pillar with air blower i/c rubbing the corrossion, painting the panel with two or more coat i/c dressing the cables etc. complete as reqd. |
| 48 | Supplying and Fixing of Landshape gate light fiiting decorative Post Top for 360 degree indirect lightwith IP 65 protection and resistant to impact and corrosion glare freeand better informity etc as required at site (Cat No. LPTO-40-CDL) |
| 49 | S/F of 16 sq. mm aluminum lugs i/c crimping connection testing etc. as reqd |
| 50 | Supplying & fixing of street light pole box of size 8\"x10\"complete all accessories i/c suitable clamps brass screws,washers and 1 No SP MCB of 10 amps capacity, 4 way DMC stud cap terminal block i/c making connections etc as required |
| 51 | Dismantling the existing accessories and depositing the same at Engineering store |