| 1 | Miatenance in Thottappallyspillway, |
| 2 | 90.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm |
| 3 | OD262425/2024-2025:Supply ,installation , testing and commissioning of Hensel make thermoplastic polycarbonate IP65 weather proof environment friendly, recyclable, UV resistant, halogen & silicon free, anti-acid & anti corrosive outdoor type8 way TPN VDB ( FP VN0800) INCOMER provision for MCB/RCCB/RCBO, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall/FRAME using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as requireddouble cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing |
| 4 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size |
| 5 | 9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 6 | 2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 7 | 2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 8 | 2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole |
| 9 | 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) |
| 10 | 90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) |
| 11 | OD262413/2024-2025:Supply and fixing 240V,MNX 18, 3Pole power contactor (L&T)and giving connection as required- |
| 12 | OD262414/2024-2025:Supply and fixing MN2 Overload relay 6-10A(L&T)and giving connection as required- |
| 13 | OD262411/2024-2025:Supply and fixingfront mounting add on Block for MNX contactor 2NO + 2NC(L&T)and giving connection as required- |
| 14 | OD262415/2024-2025:Supply and fixing NO element for gen next push button and giving connection as required- |
| 15 | OD262416/2024-2025:Supply and fixing NC element for gen next push button and giving connection as required- |
| 16 | OD262424/2024-2025:Supply and fixing LED indication lamp for all voltage ranges- Red, Green, Blue, Yellow, colour in existing panel |
| 17 | 90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet |
| 18 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 19 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 20 | 90.1.1.1:Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement,tying & fixing the conduit firmly with the re-inforcement etc. as required.20 mm |
| 21 | 5.16:Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 22 | 1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm |
| 23 | 90.12.39.5:Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3 core 4 sq mm |