| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 09-05-2025 | Technical Bid Corrigendum | Technical Bid | 15-05-2025 |
| Sl. No. | Item Description |
| 1 | CIVIL WORK |
| 2 | EXCAVATION |
| 3 | Earth work excavation for foundation (for narrow excavation)in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers.Note: The cost of earth work excavation shall be calculated based on the classifications of soils furnished in the trial pit details appended with the estimates |
| 4 | All Kind of Soil - (Upto 2.00m depth from NGL) |
| 5 | All Kind of Soil - (From 2.00m to 3.00m depth) |
| 6 | All Kind of Soil - (From 3.00m to 4.00m depth) |
| 7 | All Kind of Soil - (From 4.00m to 5.00m depth) |
| 8 | All Kind of Soil - (From 5.00m to 6.00m depth) |
| 9 | All Kind of Soil - (From 6.00m to 7.00m depth) |
| 10 | FILLING |
| 11 | Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15cm thick well rammed with surface vibrator, watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers. |
| 12 | Supplying and filling in foundation, basement, etc with conveyed earth From Quarry about 13 KM in layers of not more than 150mm thick layers well watered, rammed with surface vibrator and consolidated including conveyance charges etc. complete complying with standard specification and as directed by the departmental officers. |
| 13 | Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 14 | Supplying and filling in foundation, basement, etc with Filling Granular Sub Basein layers well watered, Without consolidation etc. complete complying with standard specification and as directed by the officers |
| 15 | PCC |
| 16 | Cement Concrete 1:4:8 (One Cement, Four crushed stone sand and eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanical means |
| 17 | Foundation level, under Plinth protection, under drawf walls and ramps including ancilary bldgs. |
| 18 | FORM WORK |
| 19 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid) |
| 20 | Footing |
| 21 | Boundary Wall & Main Gate |
| 22 | Plinth Beam |
| 23 | Column upto Plinth Level |
| 24 | RCC Wall upto Plinth Level |
| 25 | Lintel at all Levels |
| 26 | Staircase at all Levels |
| 27 | Column above Plinth Level |
| 28 | RCC wall above Plinth level |
| 29 | Roof Beam/Column drop at all Levels |
| 30 | Roof Slab at all Levels |
| 31 | Plinth Protection |
| 32 | REINFORCED CEMENT CONCRETE |
| 33 | Providing and laying in position, Standardised Concrete Mix M-25 Grade using In-situ Concrete batching plant/ Ready Mix Concrete (RMC) adopting weigh batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kglm3 and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including Conveyance of concrete from batching plant to Work site, Electricity charges and other works & labour cost involved for concrete production, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials) |
| 34 | Footing Concrete |
| 35 | Providing and laying in position, Standardised Concrete Mix M-35 Grade using In-situ Concrete batching plant/ Ready Mix Concrete (RMC) adopting weigh batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 425 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including Conveyance of concrete from batching plant to Work site, Electricity charges and other works & labour cost involved for concrete production, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 36 | RCC Lift Wall |
| 37 | Foundation upto the plinth level |
| 38 | Column |
| 39 | Foundation column upto the plinth level |
| 40 | Ground Floor |
| 41 | First Floor |
| 42 | Second Floor |
| 43 | Third Floor |
| 44 | Fourth Floor |
| 45 | Terrace Floor |
| 46 | RCC Wall |
| 47 | From Foundation upto the plinth level |
| 48 | Ground Floor |
| 49 | First Floor |
| 50 | Second Floor |
| 51 | Third Floor |
| 52 | Fourth Floor |
| 53 | Terrace Floor |
| 54 | Floor Slab/Beam Concrete |
| 55 | M - 25 Grade of concrete |
| 56 | Providing and laying in position, Standardised Concrete Mix M-25 Grade using In-situ Concrete batching plant/ Ready Mix Concrete (RMC) adopting weigh batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kglm3 and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including Conveyance of concrete from batching plant to Work site, Electricity charges and other works & labour cost involved for concrete production, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials) |
| 57 | Grade Slab |
| 58 | Plinth Beam |
| 59 | Floor Beam |
| 60 | First Floor |
| 61 | Second Floor |
| 62 | Third Floor |
| 63 | Fourth Floor |
| 64 | Terrace & Mummty Floor |
| 65 | Floor Slab |
| 66 | First Floor |
| 67 | Second Floor |
| 68 | Third Floor |
| 69 | Fourth Floor |
| 70 | Terrace Floor |
| 71 | Mummty |
| 72 | Lintel |
| 73 | First Floor |
| 74 | Second Floor |
| 75 | Third Floor |
| 76 | Fourth Floor |
| 77 | Terrace |
| 78 | STEEL REINFORCEMENT |
| 79 | Supplying, fabricating and placing in position Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete in all floors etc. complete complying with standard specification:Grade of Steel ( Fy )- Fe - 550 Confirm to IS : 1786: 1985. |
| 80 | MASONARY WORK |
| 81 | Masonry work FlyAsh Bricks of size230 x 110 x 70 mm in cement mortar 1:6 (one of cement six of sand) for sub structure & super structure in all floors including fixing frames of door and windows, proper setting, curing etc., complete complying with standard specification as directed by the departmental officers.The ratesincluding curing, providing and removal of scaffolding, cost of materials, labour, equipments and machinery, all leads and lifts, loading and unloading, transportation and all other incidential charges etc, all as complete and directed by Engineer in charge at all levels. |
| 82 | For Foundation and Basement. |
| 83 | For Superstructure in Ground Floor |
| 84 | For Superstructure in First Floor |
| 85 | For Superstructure in Second Floor |
| 86 | For Superstructure in Third Floor |
| 87 | For Superstructure in Fourth Floor |
| 88 | For Superstructure in Terrace Floor |
| 89 | Brick partition walls of 11.50cm thickness using best quality Fly Ash Bricks of size 23 x 11 x 7 cm in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers.The ratesincluding curing, providing and removal of scaffolding, cost of materials, labour, equipments and machinery, all leads and lifts, loading and unloading, transportation and all other incidential charges etc, all as complete and directed by Engineer in charge at all levels. |
| 90 | For Superstructure in Ground Floor |
| 91 | For Superstructure in First Floor |
| 92 | For Superstructure in Second Floor |
| 93 | For Superstructure in Third Floor |
| 94 | For Superstructure in Fourth Floor |
| 95 | Damp proof course with Cement Mortar 1:4 (One Cement and Four crushed stone sand) 12mm thick mixed with best approved quality water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used, finishing and curing etc. complete complying with standard specification. |
| 96 | For Main Building |
| 97 | For Boundary Wall |
| 98 | For Ancilary Building |
| 99 | JOINERIES (DOOR & WINDOWS) |
| 100 | Supply and erection of Double Leaves Fire Rated Door with Frame having the dimensions of 750mmx1500mm & 750mmx2000mm with following specification:a. Door Frame 1.6mm: Galvanized 120 GSM branded make JSWb. Door Leaf 1mm: Galvanized 120 GSM branded make JSWc. Shutter Thickness: 46mmd. Honeycomb: In-fille. Glue Macroplast UR-7221f. Door Hinges: 4\" x 3\" x 3mm, Double Ball: Make Assa Abloy Yale Ball bearing Butt Hinges Grade SS 304 - Finish SSg. Door Closer with Standard Arm Finish: Silverh. Lock Set: Dead Lock with both side keyi. Door Orientation: To be confirmed by clientj. Mounting of door: Brick wall mountedk. Powder Coating: Powder coated in standard RAL paintcolour of PO Red (60 to 90) Micronsl. Single Point Panic Bar (2 Horizontal): Make Assa Abloy Yale or Equivalentm. Dead Lock with both side key: Make Assa Abloy Yale or Equivalentn. Vision Panel 200 x 300mm 2 Hrs. Fire Glass Schott Pyran with Frameo. Rated Glass Schott Pyran with Framep. Anchor Bolt with EndcapsThe above assembly mounted on concrete or brick wall including the cost of cutting, chipping, concrete packing, plastering, scaffolding all other conveyence as per standard methods and as directed by the Departmental Officers/consultants. |
| 101 | 2 hr. fire rated Door |
| 102 | Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately) |
| 103 | Double Leaf/ Single Leaf Door |
| 104 | Providing and fixing approved make and manufacture SS 304 grade Glass to Glass Lock Round type with SS screws etc. complete in all respects as per manufacturers\" specifications & as directed by Engineer-in-charge. |
| 105 | Providing and fixing approved make & manufacture SS 304 grade D type 600mm pull handle & stopper ISI marked with 32mm dia fixed with SS screws etc. complete in all respects as per manufacturers\" specification & as directed by Engineer-in-charge. |
| 106 | Providing and fixingAutomatic Sliding door operator, Make: DORMAKABA ES 250 (EASY) 6150, compliant with future European standards and produced according to the guidelines for power-operated windows, doors and gates,BGR 232, the UVV and the VDE regulations. TÜV design tested for Durability of 1,000,000 Cycles, Manufactured according ISO 9001, tested according to the low voltage guidelines, CE Compliant, fulfils DIN 18650 standards for Padestrian Safety, for framed glass door application with DORMA ST-Flex Profiles Systems,modular design including internal cover and with 12.52 mm Laminated glass for1 Nos sliding door panels and 1 Nos fixed panels, both sliding & fixed panels with DORMAKABA ST-Flex framed profile system with Interlocking Seals.Operator & Frame Finish should be Silver Anodised, with operator dimensions (H x D) : 100 x 180 mm and of length as required to suit the opening sizes as given below. DORMAKABA ES200 Operators are of very sturdy design with Self balancing Panel suspension system and with Anti-Jump fitting.The track profile should be separate from the main profile for enabling reduction in vibration insulation. Microprocessor-controlled control unit, Self-learning, with adjustable parameters for opening and closing speed, hold-open time and opening and closing force, reversing when obstruction is encountered, Class of protection IP 20 with SMPS for Power regulation. Activators- DORMAKABA Nemo Motion + Nemo Dual ( Safety & Motion ) Pack, EM Lock - Fail Safe with CableProgram Switch with Key. Max Panel Weight Carrying Capacity of 1 X 200 Kgs. The system shall have constant power supply230V+ 5%, 50Hz, AC . The requirement in total is as mentioned below: |
| 107 | Providing wood work (75mm X125mm) in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length. ( hold fast lugs or dash fastener shall be paid for separately). |
| 108 | Second Class Teak Wood |
| 109 | French Spirit Polishing: Two or more coats on new works including a coat of wood filler |
| 110 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 111 | Supplying and fixing solid core flush shutter of following type with thickness and necessary T.W. internal lipping alround conforming to IS 2202-1(1999) including cost of wind appliances and furniture fittings such as 3 Nos of SS 304 Grade Parliament Hinges of Size (125mm x 150mm) , 2 Nos 300x12mm aluminium tower bolt 1 No. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 2 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete complying with standard specification and as directed by the departmental officers - Single leaf.Door Shutter Type : Flush shutterThickness:35mm |
| 112 | UPVC Ventilator : Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter.The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work |
| 113 | UPVC WindowSpecification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Departmental Officer before use on work . |
| 114 | Supplying, fabricating and fixing in position of Aluminium anodised natural colour matt finish of single leaf fully panelled sliding door with 12mm thick bothside prelaminated partile boardat the Shutter bottom rail:[email protected] kg/m,Top & Verticle 50x44.45x2.50mm @ 1.292 kg/m,Lock rail 50x44.45x2.50mm @ 1.292 g/m, Running channel section:[email protected] kg/m, and necessary accessories such asAlu.clips 17.15x17.27x1.50mm @ 0.176 kg, Alu handle 100x30mm @ 0.988 kg/mfull length of handles on both sides, lock, roller, including cost of materials, labour charges and power consumption charges required for fabrication including chipping, dismantling and waking hole to the required extent in RCC column, beam masonry with power drill wherever necessary and redoing the damaged portion to the original condition afterfixing etc. complete. All the Alu. sections areto be anodised.with matt finish under electically contolled condition in accordance with IS 1868/1962 for an average anodic film thickness of 15 microns etc., |
| 115 | Supplying and fixing mild steel grills for windows, ventilators, etc., including priming coat etc., complete. |
| 116 | Supplying and erecting of Gear operatedpull and push type rolling shutter with ISI make of approved size and section using 18 gauge GI sheet with hood cover including one coat of approved primer andtransport charges etc.complete in all respects, complying with relevant standard specifications and model /brand of the rolling shutter has to be got approved as directed bythe departmental officers . ROLLING SHUTTERS (WITH ISI MONOGRAM)-SOR,M-0401 (P.NO:49) |
| 117 | SS HANDRAIL |
| 118 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm fromfinishedfloorlevelweldedto38mmdia. StainlessSteelpipepostof1.00mmthick asverticalat 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete |
| 119 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails with 12mm toughened glass for breakout area using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete |
| 120 | Providing and fixing of 3 Nos of stainless steel grab bars for special need including all fixtures and complete finish. |
| 121 | PLASTERING |
| 122 | Plastering Internal with Cement Mortar 1:5 (One cement andM.sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the Engineer-incharge. |
| 123 | Ground Floor |
| 124 | First Floor |
| 125 | Second Floor |
| 126 | Third Floor |
| 127 | Fourth Floor |
| 128 | Terrace Floor |
| 129 | Plastering External with Cement Mortar 1:5 (One cement and Five Plastering sand), 20mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 130 | Ground Floor to Terrace Floor |
| 131 | Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three M.Sand) 6mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the Engineer-in charge. |
| 132 | Plastering with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including mortar plasticizer at 200ml per 50Kg of cement used, finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers. |
| 133 | Prepare surfaces and plaster with CM 1:5 (1 cement: 5 fine sand) 17mm thick(12mm+5mm) to all exteriorfaces of walls including hackingas required on RCC surfaces continuous to masonry in super structure and 12mm will be rough plastering includes water proofing chemical compound and 5mm will be sand paper finishing & double layer chicken mesh .The ratesincluding curing, providing and removal of scaffolding, cost of materials, labour, equipments and machinery, all leads and lifts, loading and unloading, transportation and all other incidential charges etc, all as complete and directed by Engineer in charge at all levels.- BASEMENT HEIGHT |
| 134 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 135 | PAINTING |
| 136 | Supplying and painting the walls with two coats of wall putty as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications (The wall putty shall be got approved by the Executive Engineer before use of work). |
| 137 | White washing two coats with base primer ,brushes, scaffolding charges, etc., complete complying with standard specification and as directed by the department officers |
| 138 | Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. |
| 139 | Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the wallssmooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification.(The colour and shade of the distemper shall be got approved by the Executive Engineer before use of work). |
| 140 | Painting two coats of newly plastered wall surface with Weather Proof Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. |
| 141 | Providing and applying Texture Finish Paint (for External painting)and approved shade including preparation of surface for painting, applying primer and two or more coats of paint as per manufacturer’s specifications, scaffolding curing etc. complete as directed at all levels. |
| 142 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 143 | Painting new wood/iron work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 144 | FLOORING & CLADDING |
| 145 | Providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two crushed stone sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panellingwherever necessary and as directed by the departmental officers) |
| 146 | 40mm thk |
| 147 | Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 of 18 / 20mm with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and threecrushed stonesand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. |
| 148 | Using Fine polished Kota Stone Slab above 600 x 600 of 18 / 20mm size |
| 149 | Kota stone slabs 18/ 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 150 | Using Fine polished Kota Stone Slab above 600 x 600 of 18 / 20mm size |
| 151 | Supplying and fixing superfine polished Ruby red or equivalent colour Granite slab 20 mm thick for Lift facia with bullnose edges are set in adhesivefor base and pointed with the same colour cement etc complete.The rate inclusive of labour charges for laying & pointing curing etc. complete |
| 152 | Supplying and fixing pre polished Ruby red or equivalent colour Granite slab 20 mm thick for Pantry and wash basin counter with bullnose edges are set in CM 1:3, 10mm thick for base and pointed with the same colour cement etc complete.The rate inclusive of labour charges for laying & pointing curing etc. complete |
| 153 | Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise andsimilar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stonesand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. |
| 154 | Fine Polished Granite Slab 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise andsimilar varieties |
| 155 | Granite wet cladding on walls/columns/cills/facias/ jambs/soffits /Bands/ skirting ;Providing and fixing Granite Stone machine cut and machine high prepolished best quality approved colour granite slab of thickness not less than 17/18mm for wall lining (veneer work)/ dadoof approximate size 1200 x 600 / 900 x 600 mm, backing filled with a grout of average 18 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand) set in laticrete adhesive L290 or equivalent, including pointing with matching colour of Laticrete or Araldite Joint filler or approved equivalent to match the granite shade including rubbing, curing and polishing including chamfering and edge polishing at exposed surfaces etc. all complete as specified and as directed by the Engineer-in-Charge all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. The cost to include all shuttering, scaffolding, props. Also it has to be ensured that the bedding mortar thickness is adjusted to achieve the desired level to flush the surfaces with adjoining finishes. |
| 156 | Fine Polished Granite Slab 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise andsimilar varieties |
| 157 | Paving the floor with best approved quality Flamed finish polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of approved colour with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints andfinishing joint with Laticrete or Araldite joint filler or approved equivalent joint filler of approved shade etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. |
| 158 | Paving the floor with best quality vitrified Tiles of following size and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 159 | 600x600mm & 10mm thk. (Double charged) |
| 160 | Providing and laying Double Charged Vitrified Tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 161 | Size of Tile 600x600 mm & 10mm thk (Double charged) |
| 162 | Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 163 | 300x300mm |
| 164 | Dadooing walls with following best approved quality, white / colour glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)Size of Tile 350x450x8mm |
| 165 | Vitrified Tile Cladding/ DadoProviding and laying Glossy/ satin matte finish Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to International Building Codes, of approved brand & manufacturer, in all colours and shade, on walls/ partitions etc in cladding/ dadolaid with cement based high polymer modified quick set tile adhesive (water based)in average 6 mm thickness or set in 1: 4 Cement Mortar, including grouting of joints using epoxy grout stainfree Laticrete/ Balendura or of approved equivalent make and brand of 0.70 kg of organic filler of desired shade (0.10kg of hardener and 0.20 kg of resin per kg), including cutting/ mitring/ curing/ filling/ grouting and finishing complete as per direction of Engineer - in - chargeSize of Tile 600x600 mm |
| 166 | Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three crushed stone Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 167 | Dadooing walls with following best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two crushed stone sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. |
| 168 | Dadooing with white glazed tiles of size 150mm x 150mm x 6mm |
| 169 | Terrace screed: Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 10mm-12 mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers. |
| 170 | Supplying & laying of Solar reflective index tiles 305 x 305 x 7 mm of 30 mm thick in cement mortar 1:3, 30 mm thick using white cement and hard crate mixed same colour pigments etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) - IN OPEN TERRACE AREA. |
| 171 | Wall Panelling:-Providing Wall Panelling using one side teak wood sheet with melamine polishing with following specification. The frame using aluminium tubular section of size 50mm x 25mm x 2mm thick fixing horizontally and vertically in position with wall at interval of 0.60m in both diretions, fixing water proof plywood of 12mm thick over the aluminium frame work with necessary screws. One side teak wood sheet of 3.5mm thick will be fixed over the plywood using fevical and finishing with melamine polishing and the rate inclusive of conveyance to site and labour charges and as directed by the Departmental Officers. The design pattern, water proof plywood, OST sheet and other materials to be used shall be got approved by the Executive Engineer concerned before use on work etc., complete. |
| 172 | Providing groove on Grantine stone for Steps and Wall cladding |
| 173 | Providing and filling the tile joint with epoxy grout with following specification: Surface preparation including cleaning the joint to be free from dust and loose particles. Providing masking tape on either side of the tile joint edges and providing sealing the tile gap with epoxy tile joint grout and finishing neatly and as directed by the departmental officers. The rate inclusive of cost of materials and labour, etc., complete. |
| 174 | Providing PVC Trims (Beading) for Toilet dadooing tiles edges |
| 175 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels Area of slab up tp 0.50 Sqm |
| 176 | WATERPROOFING |
| 177 | Below Grade Slab |
| 178 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded 1.5 mm thick HDPE waterproofing pressure sensitive adhesive membrane over PCC before laying raft concrete having higher puncture resistance of 1000N as per ASTM E 154, confirming to BS 8102 & IS 16471:2017, requirements of UG waterproofing structures. Laying adjacent sheets by keeping overlap of 75mm, end overlaps to be treated using double sided tape. The membrane shall have Tensile strength >25 Mpa as per ASTM D 412, Elongation > 500% as per ASTM D 412, Hydrostatic head resistance >70m head of water as per ASTM D 5385, Low Temperature Flexibility: -25 deg C, Peel Adhesion to Concrete >880 N/m as per ASTM D 903 Modified, UV Exposure > 45 Days. The finished cost including surface preparation completely as per specification. |
| 179 | Sunken Portion (Toilets & ODU\"s Platform) |
| 180 | Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush.Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed.Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete. |
| 181 | Terrace |
| 182 | Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geotextile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids > 85%,Tensile strength >2 Mpa as per ASTM D 412, Elongation at break >400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness >55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo-textile over the angle fillet when the first coat in still wet, treatment of cracks and laying 120GSM Geo-textile as seperation /protective layer over the fully cured PU coating completely as per specification. |
| 183 | OHT/ UGT(inside) waterproofing with Antimicrobial Coating |
| 184 | Waterproofing: Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (5 Liquid :7 Powder) to the RCC surface of the UGT/ OHT tank applied @ 2.2kg/m2 in 2 coats to achieve 1.2mm DFT, having Elongation at break >120% as per ASTM D 412, Tensile strength >1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. Followed by applying 15 mm thick dimensionally stable fibrous reinforced cementitious structural grade dual shrinkage Polymer Mortar on as protective plastering @ 29kg/m2. The material having Compressive strength of 38 MPa at 28 days as per EN 12190, Adhesive Bond Test, >1.5 Mpa as per EN 1542, followed by Water curing by sprinkling water for 3 times a day for 5- 7 days. Followed by applying two component, water-based food grade epoxy resin coatingon inside surface of Potable water tank having antialgae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 – 300 of US – FDA, having mixing Ratio (Base: Hardener: Water) – 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification. |
| 185 | STP (inside) waterproofing with Anticorrosive & Protective Coating |
| 186 | Providing and Applying two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (5 Liquid :7 Powder) to the RCC surface of the STP tank applied @ 2.2kg/m2 in 2 coats to achieve 1.2mm DFT, having Elongation at break >120% as per ASTM D 412, Tensile strength >1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. Followed by applying 15 mm thick dimensionally stable fibrous reinforced cementitious structural grade dual shrinkage Polymer Mortar on as protective plastering @ 29kg/m2. The material having Compressive strength of 38 MPa at 28 days as per EN 12190, Adhesive Bond Test, >1.5 Mpa as per EN 1542, followed by Water curing by sprinkling water for 3 times a day for 5- 7 days. followed by applying two component coal tar epoxy-based coating on inside surface of Sewage & Effluent treatment tank @ 0.30 kg/m2 in 2 coats to achieve a DFT of 200 microns when fully cured. Ensure that this coating is applied over the protective plaster. The material shall have Scratch resistance, for 7kg load as per ASTM : D 7027 - 05, Chemical resistance, immersion in dilute acid alkali & salt solutions – 7 days confirms to ASTM : C 868, Salt Spray resistance confirms to ASTM : B 117. |
| 187 | GYPBOARD FALSE CEILING |
| 188 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x 0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 189 | 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks) |
| 190 | 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks) |
| 191 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to formgrid module of size 600 x 600 mm, suspended from ceiling usinggalvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The workshall be carried out as per specifications, drawing and as per directionsof the Engineer-in- Charge. |
| 192 | With 15 mm thick Tegular edged light weight calcium sliciate false ceiling tiles |
| 193 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 194 | With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles. |
| 195 | Total of False Ceiling work |
| 196 | Toilet Cubical- Providing and fixing Toilet Cubicle (of following standard dimension which includes 600 mm door size width) made of heat, bacteria, water, chemical, scratch, impact and anti bacterial resistant 12 mm thick solid compact laminate panelsFinish of the compact laminate should be raw silk which include doors, pilasters and intermediate panels finished with approved texture/shade as per the detail drawing and as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard.This also includes providing and fixing in position necessary hardware made out of Stainless Steel (Grade 304) as per manufacturer\"s specifications and EIC instructions like (1) Door Knob, (2) Gravity Hinges, (3) Thumb turn lockset indicators, (4) Coat hooks, (5) U- Channels, (6) SS-Shoe Box Plate, (7) MS-Base Plate, (8) Rubber noise deafening tape, (9) Screws and wall Plugs.All screws will be of 304 Grade in stainless steel with satin finish. All pilasters are supported by series stainless steel shoe box with MS- Base Plate. The Base of stainless steel shoe box will be anchored to the floor with a clearance height upto 110 mm. Fixing of intermediate panels to the wall shall be stainless steel\"L\"- Bracket or stainless U- Channel section are fixed into wall with screw inserts. All screws will be of 304 Grade in Stainless steel with satin finish. All pilasters are supported by stainless steel Bottom Cladding. The base of the stainless steel bottom cladding will be anchored to the floor with a clearance height upto 110 mm. All intermidiate panels shall be 12 mm thick, pilasters and door shall be 18 mm thick with edges chamfered complete as per drawing and directions of Engineer- In- Charge. |
| 197 | Toilet Cubicle with standard dimension of 1840 mm Height x 1000 mm width x 1550 mm Depth, which include 600 mm door size width). Toilet Cubicle I- Shape (Front Partion) with standard dimension of 1840 mm Height x 1000 mm width which includes 600 mm door size width). |
| 198 | MISCELLANEOUS |
| 199 | Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below.Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers. |
| 200 | Sunken filling in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. |
| 201 | Ground Floor |
| 202 | First Floor |
| 203 | Second Floor |
| 204 | Third Floor |
| 205 | Fourth Floor |
| 206 | Providing and fixing in position Heavy duty precast SFRC. manhole cover and frame.Square shape 600mm internal dimensions |
| 207 | Providing and fixing PVC coated MS rungs as per drawing and instruction of Engineer in-charge complete. |
| 208 | Water Stops for Joints :Supply and applyof WPM SWa swellable waterbar based on polymer technology and designed for use in construction joints. |
| 209 | Providing expansion joint of 12.5mm wide in between RCC twin columns from top of pedastal to full height including filling the inner space with suitable non-absorbent, flexible and well compressible filler materials of approved quality and brand; finishing the sides of RCC columns with polysulphide sealents for a depth of 7.5mm on either side covering the inner space filled with filler materials as above etc., complete complying with standard specifications and as directed. |
| 210 | Providing and fixing of \"\" TIDEL \"\" Signage Board With Backlighting |
| 211 | Supplying and filling of Boulder by lorry for filling including conveyance loading and unloading charges and all other incidential charges filling laying watering and consolidation etc., complete as directed by the Dept., Officers with standard specification. |
| 212 | POLYURETHANE FOAM THERMAL INSULATION PANELS (PUF): Providing and Fixing of polyurethane foam as Internal Partition Wall Thermal insulation panels or Sandwich insulated panels wihboth internal and external 0.50mm total coated thickness repainted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free , high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc& accessories such as screws ,fastners ,sealants etc for fixing the panel etc., complete complying with standard specification. |
| 213 | 100mm thick PUF Internal Partition wall panel |
| 214 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality,1.5mm thick |
| 215 | Ground floor reception area |
| 216 | Extra for pre finished nosing to treads of steps of Granite stone |
| 217 | Electrical insulating mat of 6mm thick shall with standing voltage up to 65 Kv ac and 240V dc and every meter of mat tested and stamped to IS 15652-06 specifications with ISI Marking (1000mmx2000mmx6mm) |
| 218 | SS STRUCTURE & GLASS CANOPY WITH TIE ROD:Providing and fixing 13.52 mm laminated Toughned Glass (6mm clear toughned + 1.52mm PVB + 6mm Clear toughned) in canopy of structural Strainless steel frame work system in horizontal/inclined plane. The cost includes the cost of providing and fixing of glass with spider fitting and tie rod of Dorma/D-line make or quivalent and all necessary fittings for fixing of glass and joints will be sealed with wheather silicone of dow coming 789 grade to make joints leak proof and also includes all incidental includes all incidental works complete as per direction of engineer incharge. |
| 219 | The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints shall be measured. |
| 220 | Laminated glass to have / be:a) Comply with ASTM C1172.b) PVB interlayer complying with BS 6206 Class A.c) Edge steps less than 0.25mm in toughened or heat-treated glass. Annealed glasslaminate shall have no step.d) Bear identification marks indicating its nature and processor.e) Panes to have edges finished from the autoclave. Protect the interlayer material fromthe effects of moisture absorption in service including clouding, shrinking back,degassing and de-lamination.f) Ensure that the interlayer is compatible with glazing sealants. Undertake a compatibilitytest plus acceleratedweathering to ensure that leeching does not occur.g) The glass shall not delaminate. |
| 221 | Providing and Supplying Stainless Steel Structure Fabricating, Assembling, hoisting, erecting and placing in position SS Built-up section/Tubular Structure ( SS built-up section :-Rolled section & plates confirming to Grade SS-316,Tubular Structure:- made from Steel hollow sections, ISI marked conforming to GradeSS-316, in the profile shape as per drawings. The structure has to be provided as per conceptual drawings and direction of Engineer-In-Charge. |
| 222 | The complete Stainless Steel structure to be Polishing and buffing are Mate Finishing Processes For Smoothing. The work is to be executed as per technical specification and direction of Engineer-In-Charge.Mode of Measurement is Surface Area of Glass |
| 223 | Supply ans Fixing of 3mm Glass Etching Sticker Grade No.1 Good quality Material in sticker cutting materialFor Entire building as required and directed by Engineer -in-Chief |
| 224 | Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture’s specification and direction of engineer in charge all complete. |
| 225 | 75mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum plaster board conforming to IS: 2095: (part I): 2011 (Board with BIS certification marks) |
| 226 | Construction of INSPECTION CHAMBER following clear sizes including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five sand] using best quality of second class Table Mould Bricks of size 9\" x 43/8\" x 23/4\" with Plastering with Cement Mortar 1:3 [One Cement and Three Plastering Sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three crushed stone sand and Six Aggregate] 15 cm thick and covered with precast slab 5 cm thick etc., complete complying as directed by the departmental officers as per standard specification. |
| 227 | 450 x 450 mm clear opening &450 x 450 mm size FRP square manhole frame and cover -10 tonne load |
| 228 | ELEVATION |
| 229 | SEMI UNITIZEDSTRUCTURAL GLAZING SYSTEM |
| 230 | Designing the Semi Unitised Structural Glazing System with open groove joint as per design intent, preparation of shop drawings for approval, supply, fabricate, erect as per approvedshopdrawingsatallfloorlevelsandallfloor heights including conducting field test as per the test criteria set out in the particular specification (Metholodgy should be got approvedby the Dept.Officials.) Designthe framing system (i.e. male & Female frame) to support vision panels, spandrel panels either with glass or aluminium composite panel,openable,windowpanelson acontinuousframing supported between floors. Also design the split framing unutilized glazing system in case of strip or punched windows with vision panel proposed with either insulated / Monolithic glass, groove width in the system both in horizontal and vertical shall not be more than 20mm.Glazing of panel shall be done only at factory at the controlled atmosphere |
| 231 | Semiunitized system cost |
| 232 | Glass : Providing, assembling and Supplying of Double Glazed Performance glass, heat Strengthened clear Glass (IGUs) of size and shape as required and specified of approved, comprising of an outer heat strengthened clear glass of following thick of approved colour and shade with reflective soft coating on surface #2 and an inner heat strengthened clear glass of following thick , spacer tube 12mm wide , dessicants, including primary seal and secondary seal ( structural silicon sealant ) etc. all complete for the required performance , as directed by the engineer -in - charge. The heat strengthened clear glass having properties as visible Light transmittance (VLT) of 25 to 35 %, Solar heat gain coefficient less than or equal to 0.27 and U value of 3.0 to 3.3 W/m2 or lower degree K etc. The IGUs shall be assembled in the factory/ workshop of the glass processor. For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. |
| 233 | 6mm+12mm+6mm |
| 234 | Extra over for Openable:Extra over for Top hung / side hung openable aluminium window systems integrated with Unitized curtain wall system are to be fully prefabricated assembled units completed withfactory glazed panels with accessories,limit restricted stay arm, Handles, SS friction stay arm, excludes glass. All aluminium extrusion shall be Powder coating finish 50 Microns Color to architect\"s selection. Additional framing system to accommodate openable window integrated with Unitized system- Glass Qty covered in item 2b and system price in 2a.Windows all fittings such as accessories, Multi point locking, hardwares etc as per specification and to Architect selection. |
| 235 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T6 asper BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in- Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment. |
| 236 | ALUMINIUM COMPOSITE PANEL CLADDING |
| 237 | Providing and fixing of Aluminium Composite Panel (ACP) 4 sided having 50 x 25 x 1.50mm frame work vertical and horizontals out of specially designed extruded sections withstand wind pressure of 180 Kg/sq.m and fabricated fixed atalllevelelevationandheights. Theextrudedsection cutting and fixing required space extruded section shall be of 6063 and alloy of BSH 9 confirming T is – 63400 rate shall included to fix the main frame with necessary clamps, fasteners, bolt nuts etc.The main frame of extruded section shall be of 22843 & 22739 (H9) grade conforming to BS 4174 (or) IS 8147.Rate shall included 4mm thick ACP sheet (0.25 + 3.5 + 0.25) alstrong or equivalent fixing with spacer tape and the ACP sheet bounded with special type structural sealant of dow corning 789 or equivalent in dust free conditions the gaps between ACP sheet to be filed with whether sealant and backer rod or 12mm foam sheet to ensure water and air tightness in all complete complying with standard specification as directed by the departmental officerThe surface will be finished with fluorocarbon -, coating in topsides and service coating on reverse side coating confirms to the mechanical properties of panel as per detailed drawing shall include all fixing accessories,screws, washers, bolts, nuts, cleats, other required fasteners, sealant brackets, etc., complete. |
| 238 | GLASS PARTITION |
| 239 | Supply and installation of dormakaba ALTERRA Access and Cabin System for minimal frame, room dividing solutions.Single glazed mullion free demountable glass partition using Toughened/ Laminated glass in proprietarynatural anodised/Black aluminium sections ALT 50of size 50mm x 30mm with Concealed sealing(No visible Gaskets/Seals) with acoustic rating of Minimum 32 db with third party test certificate. The profile will have Carpert Groove at the Bottom on both sides for accomodating max. 8mm carpets. THe Glass to be fixed with help of Proprietary Stability GRIPPER Clampto have a stable system. It should consists of intermediate slim junction profiles for Glass to Glass vertical joints, 90 Degree L Junction and T Junction profiles suitably to be used as per room configuration designs.No VISIBLE Clip Lines to provide clutter free view at both side of section. The Glass to be Offset mounted towards outer edge leading to minimum aluminium frame on one side. Optional Profile Bottom Seal pair for additional accoustic if required. Glass thickness-10/12/13.52mm( LSG). All Profiles are min 1.5mm thickness excluding 20 microns of Anodizing, Standards applicable• Structural stability test accordance to BS 5234: Part2:1992 & EN 1991-1-1:2002 • Acoustic test for sound insulation in accordance to DIN EN ISO 10140-2 ASTME-E 90• ALT profile sections are manufactured and tested in accordance to EN573-3, EN755-2, DIN EN 12020T2 , non- dimensions manufacturing tolerance deviation DIN ISO 2768-1 class C = coarse• Toughened glass complies accordance to BS 6262 (glass supplier specification from market)• Environmental product declaration (EPD) rating accordance to ISO 14025 & EN 15804• HPDs - Ref HPD Unique Identifier; 22451 & 22452 - Classification : 09 84 00 Acoustic Room Components |
| 240 | Providing, fabricating and fixing in position M.S. Structure made out of M.S. rolled/hollow (rounds/rectangular/ square etc.) sections as per architect’s details including shearing /cutting, riveting, welding, grinding to smooth surface of all works, MS fixing holdfasts / anchor bolts to be grouted in concrete1:2:4 , providing and fixing nuts bolts fasteners as required as per architect’s details, including painting with two or more coats of first quality synthetic enamel paint of approved quality and make over a coat of primer etc. complete as directed. ( MS standard section shall be measured and paid under relevant Item. Nuts, bolts, washersshall be deemed to have been included in the unit rates and nothing extra shall be paid for) |
| 241 | Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. |
| 242 | Providing & fixing concept wallpapers with wording & arts etc. as per direction of engineer-in charge. |
| 243 | PVC / Fibre Glass Framed 5.5mm thick Mirror, Shelf Typewith Hard Board Backing |
| 244 | Supplying and fixing colour galvalume sheet roof of 0.47mm thickand steelfixing in position with all necessary accessories complete complying with standard specification and as directed by the departmental officers. |
| 245 | Manufacturing supplying and fixing in position of teracotta jally 20x20x5cmthick approved quality and design in cement slurry including cost of materials labour curing lifting fixing in position etc, complete complying with standard specification and as directed by the departmental officers . |
| 246 | Land Development |
| 247 | Providing and laying 83mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge |
| 248 | Manufacturing, supply & fixing of precast kerb stone of size 400mmx259mmx200mm thick made of M 20 grade of concrete rectangular in shape with one corner chamfered by 100 mm x 100 mm as per approved design i/c cost of all material, labour and curing etc., complete. as per IRC 5758 - 1984. |
| 249 | Providing and laying of hot applied Thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes etc., complete as per MoRT&H specification No.803 |
| 250 | LANDSCAPE |
| 251 | Providing and fixing Neelgiri/Mexican grass turf with earthy 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light, watering direction of officer incharge. |
| 252 | Small shrubs- 1,6\" ht |
| 253 | Tall shrubs - 1, - 2, ht |
| 254 | Ground covers: Towards cost and supply of Ground covers, inclusive of pitting and planting(1 Sft) |
| 255 | Hedges: Towards cost and supply of Hedges, inclusive of pitting and planting |
| 256 | Accent Trees: Towards cost and supply of Accent trees, inclusive of pitting and planting |
| 257 | Plumeria alba |
| 258 | Terminalya mantaly |
| 259 | Accent palms: Towards cost and supply of Accent palms, inclusive of pitting and planting |
| 260 | Foxtail palm |
| 261 | Soil Work: |
| 262 | Towards cost of soil mix (i.e Garden Soil and Manure) |
| 263 | Irrigation work |
| 264 | ELECTRICAL |
| 265 | HT WORKS: |
| 266 | 11kV DP STRUCTURE (TNEB Side) |
| 267 | Supply, erection, Testing and commissioning of the \"11KV Two pole (DP) structure using 2 Nos. of 200 x 100mm ISMB Poles, of 9.145 meter long with 450 x 450 x 6mm base plate welded to the pole bottom, \"1 Set of 100 x 50 x 6mm ISMC and angles, clampsto support the A.B. switch, H.G. fuse, line disc insulators, pin insulators, Lightning arresters,\" M.S. clamps to fix the channels made out of 50 x 8mm M.S. flats and required angles as struts for cantilever projection to mount the A.B. switch, stay sets cable supports etc., Supply and fixing of 11KV, 400A single break tandem operated A.B. switch with operating pipe, operating handle with ON-OFF position indications and locking facility, guided, flexible earth for down rod pipe and other accessories, 1Set of 11KV HG fuse, 3 Nos. of station type 11kV Lightning arrestors, 11KV HT Pin insulators with long pin / A stool - 12 nos, 11kV Disc insulators with metal parts - 6 Nos., Stay set complete with guy insulators - 2 Set, ACSR Conductor jumpering works and complete painting works.\"Note : Including All civil work like excavation, concreting, and back filling, etc., |
| 268 | 11kV DP STRUCTURE (Consumer Side) |
| 269 | Supply, erection, Testing and commissioning of the \"11KV Two pole (DP) structure using 2 Nos. of 200 x 100mm ISMB Poles, of 9.145 meter long with 450 x 450 x 6mm base plate welded to the pole bottom, \"1 Set of 100 x 50 x 6mm ISMC and angles, clampsto support the A.B. switch, H.G. fuse, line disc insulators, pin insulators, Lightning arresters,\" M.S. clamps to fix the channels made out of 50 x 8mm M.S. flats and required angles as struts for cantilever projection to mount the A.B. switch, stay sets cable supports etc., Supply and fixing of 11KV, 400A double break tandem operated A.B. switch with operating pipe, operating handle with ON-OFF position indications and locking facility, guided, flexible earth for down rod pipe and other accessories, 1Set of 11KV HG fuse, 3 Nos. of station type 11kV Lightning arrestors, 11KV HT Pin insulators with long pin / A stool - 12 nos, 11kV Disc insulators with metal parts - 6 Nos., Stay set complete with guy insulators - 2 Set, \"0\" SWG Copper jumpering arrangments, etc., and complete painting works. \"Note : Including All civil work like excavation, concreting, and back filling, etc., |
| 270 | HT METERING CUBICLE |
| 271 | Supply, erection, Testing and commissioning of the \"11KV HT Metering Cubicle with 4Core multistranded copper cable between Metering Cubicle to CT-PT, terminal blocks, busbar arrangements, interconnection wiring, etc., as per TNEB Standards and requirements |
| 272 | HT YARD FENCING |
| 273 | Supply and installation of GI HT Yard Fencing using 75 x 75mm 10SWG chain link mesh to a height of 1.8Mtrs. above ground level and a retaining wall with brick all around to a height of 330mm above ground with vertical members of 50 x 6mm ISA at 1.5mtr. Internal and tie angle at top with 25 x 6mm ISA including all the civil works. |
| 274 | Supply and installation of 1.8mtr. Height and 1.5mtr. Width single leaf gate made out of 50 x 6mm ISA cross supports fixed on 100 x 50 x 6mm ISMC and covered with 75 x 75mm chain link mesh with pad locking arrangements. |
| 275 | Supply and installation of 1.8mtr. Height and 2 x 1.5mtr. Width Double leaf gate made out of 50 x 6mm ISA cross supports fixed on 100 x 50 x 6mm ISMC and covered with 75 x 75mm chain link mesh with pad locking arrangements. |
| 276 | Supply and providing the HT Yard using spreading 40mm blue metal to a height of 75mm and river sand bed upto 75mm height, including levelling, etc., |
| 277 | 11KV HT 3VCB (1IC+2O/G) PANEL (OUTDOOR) |
| 278 | Supply, erection, Testing and commissioning of 11kV HT 3VCB Outdoor drawout type Panel board comprising of the followings: 1 No. VCB as Incomer + 2 Nos. VCB as Outgoings as per IEC 62271-200 type floor standing, sheet steel clad cubicle type. \"VACUUM CIRCUIT BREAKER:\" 11kV 800A, 25kA/3Secs., Draw-out type VCB with Power Module, \"Spring charging Motor: 230V AC, Closing/Tripping Coil: 24V DC, Aux. Contacts: 4NO+4NC.\"CURRENT TRANSFORMER:\"11kV Indoor Resin Cast C.T,\"INCOMER Ratio:100-75/5-5A, \"OUTGOINGS 75-50/5A-5A-3SETS, Core-1: 0.2/15VA, Core-2: 5P20/15VA, \"STR : 100 OCF. VOLTAGE TRANSFORMER: 11kV Indoor Resin Cast Fixed PT, \"Ratio: 11kV/rt3/110V/rt3, Core 1 : Cl.: 0.5, Burden: 100VA. PROTECTION DEVICES:\"3 O/C + 1 E/F Relay 50/51/50N/51N - (IRI-PRO-V4),\"High Speed Tripping Relay (CLR-H),\"Auxiliary Relay (VAA33) - 3 Element,\"Anti - Pumping Contactor ,\"Digital Multi Function Meter With RS485 Port,\"Digital Ammeter with Selector Switch,\"Digital Voltmeter with Selector Switch,\"ON / OFF / TRIP / TCH / Spring Charged Indication Lamps, \"R,Y,B Phase Indication Lamps,\"Power Pack ( 230V AC - 24V DC ),\"Surge Arrestor (27kV,10kA) -TYPE II,\"T-N-C Switch (Breaker Control Switch),\"Local/Remote Switch,\"8 Window Annunciator ,\"16 Window Annunciator,\"Buzzer,\"Pushbutton for ACCEPT/RESET, \"Control wiring with appropriate colours,\"Control Fuses,\"Space Heater / Thermostat,\"Dis-Connecting Terminal Blocks - CT Circuits,\"Terminal Blocks - Control Circuits,\"Illumination Lamp,\"Toggle Switch for Heater ON/OFF,\"Door Limit Switch,\"BUSBAR CONNECTIONS:-\"Main Connections:Copper - 1RX80x10mm ,\"Earth Connections:Copper - 50x06mm, CRCA sheet steel enclosure suitable for outdoor (IP65) installation with the provision for receiving incoming & outgoing power cable through rear side bottom entry. (Shade: RAL7032). |
| 279 | 11kV/433V, 630kVA TRANSFORMER WITH OLTC |
| 280 | Design, Supply, Erection,Testing and Commissioning of 11kV/433V, 630kVA TRANSFORMERwith OLTC & RTCC Panel comprising of bi-directional roller, diagram, rating plate, winding temperature indicator, marshalling box, lifting lugs and weather proof HT cable box, LT Cable box disconnecting chamber minimum 8mm thick non magnetic gland plate complete as per specification and as per IS : 1180 / 2026 and as perthe ECBC norms. Including all the civil worksa) Copper wound On Load Tap Changer Transformer b) IS : 1180 (Part I) : 2014 ,Amendment No.4, Level-IIc) Capacity - 630 KVA, Dyn 11d) Primary - 11000 Voltse) Secondary - 433 Voltsf) On Load Tap Changer, +/-10% Iin steps 1.25%g) HV - 28 KV h) LV - 3 KVi) ONAN, Outdoor type(Make : ABB/HITACHI/CG/SCHENIDER/VOLTAMP) |
| 281 | HT CABLE & END TERMINATIONS |
| 282 | Supply and Laying of 11KV 3 Core 240 Sq.mm, HT XLPE insulated (E)Aluminium cable.The cable shall be laid in the cable tray which is fixed inside the cable trench as required as per the site condition |
| 283 | Supply and fxing of the HT Cable Heat shrinkable outdoor type end termination kit for suitable for terminating 3core 240 Sq.mm, HT XLPE Aluminium [E] cable with all the accessories. |
| 284 | Supply and fxing of the HT Cable Heat shrinkable Indoor type end termination kit for suitable for terminating 3core 240 Sq.mm, HT XLPE Aluminium [E] cable with all the accessories. |
| 285 | Supply and laying of 3Runs of 300mm dia. RCC Hume pipe protection of class \"NP2\" including excavation of existing ground for laying of Hume pipe. The excavated trench should be of 1000mm depth 900mm width. After laying of Hume pipes it is vendor responsibility to make the original surface and hand over to the client. |
| 286 | Supply and construction of 1200 x 1200 x 1000mm Manhole chamber including earth excavation works, PCC, brickwall construction and RCC heavy duty top cover with mounting frame |
| 287 | EARTHING |
| 288 | Supply, installation and testing of UL Listed 17.2mm dia. 3000mm long, copper bonded rod earth electrode station complying to IS 3043 standards in all respects with excavation in all types of soil, murrum or rock, filling with earth enhancing compound material, durable 450mm x 450mm masonry chamber in rich plastered brick work and approved quality heavy duty CI or RCC cover, etc., The earth pit identification shall be marked with paint on the cover in an approved manner |
| 289 | Supply, installation and testing of Copper Plate earth electrode station using 600 x 600 x 3.15mm Copper plate with 50mm dia. 3mtr long GI pipe with watering funnel, 2Rx25x6mm Copper strip as vertical run, connecting top clamp, etc., complying to IS 3043 in all respects with excavation in all types of soil, murrum or rock, filling with earth enhancing compound material, durable 450mm X 450mm masonry chamber in rich plastered brick work and approved quality heavy duty CI or RCC cover, etc., The earth pit identification shall be marked with paint on the cover in an approved manner. (Transformer & DG neutral earthing) |
| 290 | Supply and laying of 25 x 3mm copper flats for Transformer body earth, Generator body, DP structure, HT LA Earthing, HT VCB Panel and LT Panels earthing |
| 291 | Supply and laying of 50 x 6mm copper flat for 630KVA Transformers neutral earthing |
| 292 | Supply and laying of No. 8 SWG bare Copper earth wire |
| 293 | Supply and installation of 2m x 1m Rubber Mat suitable for 11KV installation confirming to IS (1Set = 5 Nos) |
| 294 | Supply and installation of First Aid Box complete with all First Aid Medicines |
| 295 | Supply and installation of Shock Treatment Chart fixed in glass frame |
| 296 | Supply and installation of4 Nos. Fire Buckets made out of 40 x 40 x 6mm MS Angle |
| 297 | Supply and installation of Metallic Danger Board as required by the Electrical Authorities |
| 298 | Supply and installation of Earth Discharge Rod |
| 299 | Supply and installation of 11kV HT Hand Gloves (ISI Approved) |
| 300 | L.T. SWITCHGEAR(PANEL BOARDS) |
| 301 | The Switchboard shall be designed so as to receive cables suitable for bottom / top entry and bottom / top exit to suit site conditions. For complete technical details refer schematic drawing/layouts.. The panel shall be Double front/single front\"Linear\" or \"L\" or \"U\" shape to suit proposed electrical room. Panel shall be powder coated with approved shade.\"Rate shall include necessary sheet steel enclosure made out of 14 SWG sheet steel duly powder coated with the same paint shade of panel board adopter box to cover the cables and conduits above the panel to the acceptance of Consultant.\"Design, manufacturing, Supply at site, Unloading, Leading, Positioning, Erecting, Earthing, Testing and Commissioning of panels offree standing type, vermin proof, construction as per tender technical specification and the details mentioned separately,\"Note: AllMCCBs in all panels shall have rotary handle mechanism and spreader wherever necessary.,\"All ACBs with shutter release assembly, door interlock,\"As per specification all outgoing MCCBs in the Main panel / distribution boards and incoming MCCBs of all Sub distribution panel boardsshall be of adjustable overload and short circuit protection settings.\"The outgoing MCCBs in the Sub Panels needs adjustable thermal overload settings only and fixed short circuit setting.\"i. 35KA - above 250A up to 630A ii. 25KA for above 63A & up to 250A. iii. 16KA - up to 63A.\"The KA rating of the MCCBs shall follow as per the BOQ. The KA rating for the Incomer of the Vertical MCCB DBs shall be of 16 KA rating only.\"Details of LT Panels : The details of components, ratings etc. of all panels are furnished in Power distribution schematic diagram,\"Electrical Room Size : Vendor/Contractor to ensure that the panel/room layoutsare designed with adequate clearances as per IE rulesin theproposedElectrical rooms and can be accommodated in the designated space for electrical rooms. |
| 302 | MAIN LT PANEL |
| 303 | Design, fabrication, supply, installation, testing and commissioning of cubicle floor mounting type, Indoor-IP54, compartmentalized, cable alley chamber, dust and vermin proof Main LT Panel board made out of 14SWG CRCA sheet comprising of the followings: |
| 304 | EB INCOMER - 1 & 2:2 Nos. 1000Amps, 50kA, 4Pole. Electrical Draw out type Air Circuit Breaker with Shunt release, UV release and E/F Releases and microprocessor based LSING with current metering display system |
| 305 | EB METERING - 1 & 2:2 Set of RYB Phase indication LED lamps2 set of Breaker ON, Breaker OFF, Breaker Trip LED indication lamps2 No. Digital Multi Function Meter with RS485 port (Selec MFM 384-C-CE)2 Set of 1000/5A, CL-1 Resin Cast CT for metering 2 set of 1000/5A, CL-5P10 Resin Cast CTs for Protection relay2 set of 1000/5A, Cl-1 CT for APFCR Panel sensing 2 Nos. CDG-11 Overcurrent & Earth fault relay 2 Set of LVM, SPP and PPR.4 Set of Control MCBs2 Set of TVSS - Surge Protection Device (Type-1+2) with MPCB2 Nos. T-N-C Control Switch |
| 306 | DG NCOMER - 1 & 2:2 Nos. 800Amps, 50kA, 4Pole. Electrical Draw out type Air Circuit Breaker with Shunt release, UV release and E/F Releases and microprocessor based LSING with current metering display system |
| 307 | DG METERING - 1 & 2:2 Set of RYB Phase indication LED lamps2 set of Breaker ON, Breaker OFF, Breaker Trip LED indication lamps2 Nos. Digital Multi Function Meter with RS485 port (Selec MFM 384-C-CE)2 Set of 800/5A, CL-1 Resin Cast CT for metering 2 Set of LVM, SPP and PPR.4 Set of Control MCBs2 Set of TVSS - Surge Protection Device (Type-1+2) with MPCB2 Nos. T-N-C Control Switch |
| 308 | BUS COUPLER :1 No. 1250Amps, 50kA, 4Pole. Electrical Draw out type Air Circuit Breaker with E/F Releases and microprocessor based LSING with current metering display system |
| 309 | BUS BAR: (Copper)1250Amps, 50kA, for 1 Sec. TPN, Copper bus bars (Current Density not less than 1.2A/Sq.mm) with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable copper earth bus. |
| 310 | Cable Entry & Exit :Top/ Bottom Gland Plate : 3mm thickness removable plateSpace heater with thermostat for Cable chambers |
| 311 | Complete with PLC with HMI based Interlocking system for automatic load balancing and load sharing options during power failure / changeover time |
| 312 | OUTGOINGS:4 Nos. 800Amps, 50kA, TP+N, Electrical Draw out type Air Circuit Breaker with microprocessor based OC, SC & E/F Releases 2 Nos. 630Amps, 35kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC and extended RHOM, spreaders, phase barriers, etc., 1 No. 400Amps, 35kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC and extended RHOM, spreaders, phase barriers, etc., 4 Nos. 250Amps, 35kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC and extended RHOM, spreaders, phase barriers, etc., |
| 313 | Note : All the Outgoing feeder shall be having \"ON-OFF\" LED Indication lamps with Digital Multi Function Meter with RS485 port (Selec MFM 384-C-CE). Suitable size outgoing cable chamber and extension busbars with shrouded partition between each outgoing feeder should be provided for connecting the number of outgoing cables as per the schematic drawing. The board shall be fabricated for future extension and complete with 75x40mm ISMC base frame arrangements. |
| 314 | APFCR PANEL - 1 & 2 |
| 315 | Design, fabrication, supply, installation, testing and commissioning of cubicle floor mounting type, Indoor-IP54,compartmentalized, cable alley chamber, dust and vermin proof APFCR Panel boards made out of 14SWG CRCA sheet comprising of the followings: |
| 316 | INCOMER:1 No. 630Amps, 35kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC and extended RHOM, spreaders, phase barriers, etc., |
| 317 | METERING:1 Set of RYB Phase indication LED lamps1 set of Breaker ON, Breaker OFF, Breaker Trip LED indication lamps1 No. Digital type Multi Function Meter with RS485 port1 Set of 630/5A, CL-1 Resin Cast CT for metering 1 No. 12Stage Microprocessor based APFC Relay .1 Set of Control MCBs1 Set of TVSS - Surge Protection Device (Type-1+2) with MPCB1 No. T-N-C Control Switch |
| 318 | BUS BAR: (Copper)630Amps, 35kA, for 1 Sec. TPN, Copper bus bars (Current Density not less than 1.2A/Sq.mm) with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable copper earth bus. |
| 319 | Cable Entry & Exit :Top & BottomGland Plate : 3mm thickness removable plateSpace heater with thermostat for Cable chambers |
| 320 | 1 No. 50kVAR, Heavy duty APP type capacitor bank with capacitor duty contactor, 7% Detuned copper reactor, ON-OFF Illuminated Push buttons, control MCB, internal control and power wiring arrangements, etc., and controlled by 1 No. 160Amps, 25kA, TP+N, MCCB with thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc., |
| 321 | 3 Nos. 25kVAR, Heavy duty APP type capacitor bank with capacitor duty contactor, 7% Detuned copper reactor,ON-OFF Illuminated Push buttons, control MCB, internal control and power wiring arrangements, etc., and controlled by 3 Nos. 100Amps, 25kA, TP+N, MCCB with thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc.,with 1 No. Dummy chamber suitable for 25kVAR |
| 322 | 3 Nos. 15kVAR, Heavy duty APP type capacitor bank with capacitor duty contactor, 7% Detuned copper reactor,ON-OFF Illuminated Push buttons, control MCB, internal control and power wiring arrangements, etc., and controlled by 3 Nos. 63Amps, 25kA, TP+N, MCCB with thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc., |
| 323 | 2 Nos. 10kVAR, Heavy duty APP type capacitor bank with capacitor duty contactor, 7% Detuned copper reactor,ON-OFF Illuminated Push buttons, control MCB, internal control and power wiring arrangements, etc., and controlled by 2 Nos. 40Amps, 25kA, TP+N, MCCB with thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc., |
| 324 | 2 Nos. 05kVAR, Heavy duty APP type capacitor bank with capacitor duty contactor, 7% Detuned copper reactor,ON-OFF Illuminated Push buttons, control MCB, internal control and power wiring arrangements, etc., and controlled by 2 Nos. 32Amps, 25kA, TP+N, MCCB with thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc., |
| 325 | UTILITY PANEL: |
| 326 | Design, fabrication, supply, installation, testing and commissioning of cubicle floor mounting type, Indoor-IP54,compartmentalized, cable alley chamber, dust and vermin proof UTILITY Panel board made out of 14SWG CRCA sheet comprising of the followings: |
| 327 | INCOMER:1 No. 250Amps, 35kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc., |
| 328 | METERING:1 Set of RYB Phase indication LED lamps1 set of Breaker ON, Breaker OFF, Breaker Trip LED indication lamps1 No. Digital Multi Function Meter with RS485 port (Selec MFM 384-C-CE)1 Set of 250/5A, CL-1 Resin Cast CT for metering 1 Set of Control MCBs |
| 329 | BUS BAR: (Copper)250Amps, 35kA, for 1 Sec. TPN, Copper bus bars (Current Density not less than 1.2A/Sq.mm) with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable copper earth bus. |
| 330 | Cable Entry & Exit :Top Gland Plate : 3mm thickness removable plateSpace heater with thermostat for Cable chambers |
| 331 | OUTGOINGS:2 Nos. 160A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc.,3 Nos. 125A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc.,2 Nos. 100A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc.,4 Nos. 63A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc., |
| 332 | HVAC ODU PANEL (Terrace Floor) |
| 333 | Design, fabrication, supply, installation, testing and commissioning of cubicle floor mounting type, Indoor-IP54,compartmentalized, cable alley chamber, dust and vermin proof HVAC ODU Panel board made out of 14SWG CRCA sheet comprising of the followings: |
| 334 | INCOMER - 1 & 22 Nos. 160Amps, 25kA, 4Pole, Motorised type MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc., |
| 335 | Electro-Mechanical Interlocking arrangements between Incomer -1 and Inocmer-2 for Auto Changover system |
| 336 | METERING:2 Set of RYB Phase indication LED lamps2 set of Breaker ON, Breaker OFF, Breaker Trip LED indication lamps2 No. Digital Multi Function Meter with RS485 port (Selec MFM 384-C-CE)2 Set of 160/5A, CL-1 Resin Cast CT for metering 1 Set of Control MCBs |
| 337 | BUS BAR: (Copper)160Amps, 25kA, for 1 Sec. TPN, Copper bus bars (Current Density not less than 1.2A/Sq.mm) with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable copper earth bus. |
| 338 | Cable Entry & Exit :Top Gland Plate : 3mm thickness removable plateSpace heater with thermostat for Cable chambers |
| 339 | OUTGOINGS:7 Nos. 63A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc., |
| 340 | SUB-SWITCH BOARD - 1(GF) |
| 341 | Design, fabrication, supply, installation, testing and commissioning of cubicle floor mounting type, Indoor-IP54,compartmentalized, cable alley chamber, dust and vermin proof SSB-1 Panel board made out of 14SWG CRCA sheet comprising of the followings: |
| 342 | INCOMER - 1 & 22 Nos. 200Amps, 25kA, 4Pole, Motorised type MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc., |
| 343 | Electro-Mechanical Interlocking arrangements between Incomer -1 and Inocmer-2 for Auto Changover system |
| 344 | METERING:2 Set of RYB Phase indication LED lamps2 set of Breaker ON, Breaker OFF, Breaker Trip LED indication lamps2 No. Digital Multi Function Meter with RS485 port (Selec MFM 384-C-CE)2 Set of 200/5A, CL-1 Resin Cast CT for metering 1 Set of Control MCBs |
| 345 | BUS BAR: (Copper)200Amps, 25kA, for 1 Sec. TPN, Copper bus bars (Current Density not less than 1.2A/Sq.mm) with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable copper earth bus. |
| 346 | Cable Entry & Exit :Top Gland Plate : 3mm thickness removable plateSpace heater with thermostat for Cable chambers |
| 347 | OUTGOINGS:2 Nos. 125A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc.,4 Nos. 100A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc.,2 Nos. 63A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc., |
| 348 | Note : All the Outgoing feeder shall be having \"ON-OFF\" LED Indication lamps with Digital Multi Function Meter with RS485 port (Selec MFM 384-C-CE). Suitable size outgoing cable chamber and extension busbars with shrouded partition between each outgoing feeder should be provided for connecting the number of outgoing cables as per the schematic drawing. The board shall be fabricated for future extension and complete with 75x40mm ISMC base frame arrangements. |
| 349 | SUB-SWITCH BOARD - 2 to 5(1F to 4F) |
| 350 | Design, fabrication, supply, installation, testing and commissioning of cubicle floor mounting type, Indoor-IP54,compartmentalized, cable alley chamber, dust and vermin proof SSB-2 to 5 Panel boards made out of 14SWG CRCA sheet comprising of the followings: |
| 351 | INCOMER - 1 & 22 Nos. 250Amps, 25kA, 4Pole, Motorised type MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc., |
| 352 | Electro-Mechanical Interlocking arrangements between Incomer -1 and Inocmer-2 for Auto Changover system |
| 353 | METERING:2 Set of RYB Phase indication LED lamps2 set of Breaker ON, Breaker OFF, Breaker Trip LED indication lamps2 No. Digital Multi Function Meter with RS485 port (Selec MFM 384-C-CE)2 Set of 250/5A, CL-1 Resin Cast CT for metering 1 Set of Control MCBs |
| 354 | BUS BAR: (Copper)250Amps, 25kA, for 1 Sec. TPN, Copper bus bars (Current Density not less than 1.2A/Sq.mm) with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable copper earth bus. |
| 355 | Cable Entry & Exit :Top Gland Plate : 3mm thickness removable plateSpace heater with thermostat for Cable chambers |
| 356 | OUTGOINGS:6 Nos. 100A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc.,2 Nos. 63A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc., |
| 357 | Note : All the Outgoing feeder shall be having \"ON-OFF\" LED Indication lamps with Digital Multi Function Meter with RS485 port (Selec MFM 384-C-CE). Suitable size outgoing cable chamber and extension busbars with shrouded partition between each outgoing feeder should be provided for connecting the number of outgoing cables as per the schematic drawing. The board shall be fabricated for future extension and complete with 75x40mm ISMC base frame arrangements. |
| 358 | SUB-SWITCH BOARD - 6(Terrace) |
| 359 | Design, fabrication, supply, installation, testing and commissioning of cubicle floor mounting type, Indoor-IP54,compartmentalized, cable alley chamber, dust and vermin proof SSB-5 Panel board made out of 14SWG CRCA sheet comprising of the followings: |
| 360 | INCOMER - 1 & 22 Nos. 250Amps, 25kA, 4Pole, Motorised type MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc., |
| 361 | Electro-Mechanical Interlocking arrangements between Incomer -1 and Inocmer-2 for Auto Changover system |
| 362 | METERING:2 Set of RYB Phase indication LED lamps2 set of Breaker ON, Breaker OFF, Breaker Trip LED indication lamps2 Nos. Digital Multi Function Meter with RS485 port (Selec MFM 384-C-CE)2 Set of 250/5A, CL-1 Resin Cast CT for metering 1 Set of Control MCBs |
| 363 | BUS BAR: (Copper)250Amps, 25kA, for 1 Sec. TPN, Copper bus bars (Current Density not less than 1.2A/Sq.mm) with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable copper earth bus. |
| 364 | Cable Entry & Exit :Top Gland Plate : 3mm thickness removable plateSpace heater with thermostat for Cable chambers |
| 365 | OUTGOINGS:6 Nos. 125A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc., with Digital Multi Function Meter with RS485 port (Selec MFM 384-C-CE) and Current Transformers11 Nos. 32A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc., |
| 366 | Note : All the Outgoing feeder shall be having \"ON-OFF\" LED Indication lamps. Suitable size outgoing cable chamber and extension busbars with shrouded partition between each outgoing feeder should be provided for connecting the number of outgoing cables as per the schematic drawing. The board shall be fabricated for future extension and complete with 75x40mm ISMC base frame arrangements. |
| 367 | LIFT MAIN PANEL: |
| 368 | Design, fabrication, supply, installation, testing and commissioning of cubicle floor mounting type, Indoor-IP54,compartmentalized, cable alley chamber, dust and vermin proof LIFT MAIN Panel boards made out of 14SWG CRCA sheet comprising of the followings: |
| 369 | INCOMER :1 No. 125Amps, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc., |
| 370 | METERING:1 Set of RYB Phase indication LED lamps1 set of Breaker ON, Breaker OFF, Breaker Trip LED indication lamps1 No. Digital Multi Function Meter with RS485 port (Selec MFM 384-C-CE)1 Set of 125/5A, CL-1 Resin Cast CT for metering 1 Set of Control MCBs |
| 371 | BUS BAR: (Copper)125Amps, 25kA, for 1 Sec. TPN, Copper bus bars (Current Density not less than 1.2A/Sq.mm) with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable copper earth bus. |
| 372 | Cable Entry & Exit :Top Gland Plate : 3mm thickness removable plateSpace heater with thermostat for Cable chambers |
| 373 | OUTGOINGS:6 Nos. 63A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc., |
| 374 | Note : All the Outgoing feeder shall be having \"ON-OFF\" LED Indication lamps. Suitable size outgoing cable chamber and extension busbars with shrouded partition between each outgoing feeder should be provided for connecting the number of outgoing cables as per the schematic drawing. The board shall be fabricated for future extension and complete with 75x40mm ISMC base frame arrangements. |
| 375 | DG SYNC. PANEL |
| 376 | Design, fabrication, supply, installation, testing and commissioning of cubicle floor mounting type, Indoor-IP54,compartmentalized, cable alley chamber, dust and vermin proof DG SYNC. Panel boards made out of 14SWG CRCA sheet comprising of the followings: |
| 377 | DG NCOMER - 1 & 2:2 Nos. 800Amps, 50kA, 3Pole. Electrical Draw out type Air Circuit Breaker with 400A, NEUTRAL CONTACTOR Shunt release, UV release and E/F Releases and microprocessor based LSING with current metering display system |
| 378 | METERING:2 Set of RYB Phase indication LED lamps2 set of Breaker ON, Breaker OFF, Breaker Trip LED indication lamps2 Nos. Digital Multi Function Meter with RS485 port (Selec MFM 384-C-CE) 2 Set of 800/5A, CL-1 Resin Cast CT for metering 2 Set of Class PS CT with Earth fault relay2 Set of Control MCBs2 Set CBCT with ELR1 Set DG Synchronizing relay2 Nos. Annunciator |
| 379 | BUS BAR: (Copper)1250Amps, 50kA, for 1 Sec. TPN, Copper bus bars (Current Density not less than 1.2A/Sq.mm) with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable copper earth bus. |
| 380 | Cable Entry & Exit :Top Gland Plate : 3mm thickness removable plateSpace heater with thermostat for Cable chambers |
| 381 | OUTGOINGS:2 Nos. 800Amps, 50kA, 4Pole. Electrical Draw out type Air Circuit Breaker with microprocessor based OL & SC releases. |
| 382 | Note : All the Outgoing feeder shall be having \"ON-OFF\" LED Indication lamps. Suitable size outgoing cable chamber and extension busbars with shrouded partition between each outgoing feeder should be provided for connecting the number of outgoing cables as per the schematic drawing. The board shall be fabricated for future extension and complete with 75x40mm ISMC base frame arrangements. |
| 383 | Supply and erection of 32/63/100Amps, 4P MCCB with RYB LED Indication lamps, control MCB and in suitable powder coated type MS enclosure with all the fixing accessories |
| 384 | Supply and erection of 32/63/100Amps, 4P MCCB with RYB LED Indication lamps, control MCB and in suitable powder coated outdoor weather proof type MS enclosure with all the fixing accessories |
| 385 | Supply and erection of 20Amps, 1Phase, 3Pin Industrial type Plug and socket with 25Amps, 30mA DP RCCB in suitable size MS enclosure with all the fixing accessories |
| 386 | Supply and erection of 32Amps, 3Phase, 3Pin Industrial type Plug and socket with 32Amps, 4P MCB in suitable size MS enclosure with all the fixing accessories |
| 387 | Supply and erection of 6-32Amps, DP MCB with suitable MS enclosure with all the fixing accessories |
| 388 | Supply and erection of 6-32Amps, 4P MCB with suitable MS enclosure with all the fixing accessories |
| 389 | Supply and erection of 40-63Amps, 4P MCB with suitable MS enclosure with all the fixing accessories |
| 390 | Supply, laying, and testing of 3.5C x 400 Sq.mm 1.1kV grade FRLS XLPE insulated aluminium conductor armoured cable |
| 391 | Supply, laying, and testing of 3.5C x 300 Sq.mm 1.1kV grade FRLS XLPE insulated aluminium conductor armoured cable |
| 392 | Supply, laying, and testing of 3.5C x 185 Sq.mm 1.1kV grade FRLS XLPE insulated aluminium conductor armoured cable |
| 393 | Supply, laying, and testing of 3.5C x 150 Sq.mm 1.1kV grade FRLS XLPE insulated aluminium conductor armoured cable |
| 394 | Supply, laying, and testing of 3.5C x 120 Sq.mm 1.1kV grade FRLS XLPE insulated aluminium conductor armoured cable |
| 395 | Supply, laying, and testing of 3.5C x 70 Sq.mm 1.1kV grade FRLS XLPE insulated aluminium conductor armoured cable |
| 396 | Supply, laying, and testing of 3.5C x 35 Sq.mm 1.1kV grade FRLS XLPE insulated aluminium conductor armoured cable |
| 397 | Supply, laying, and testing of 4C x 25 Sq.mm 1.1kV grade FRLS XLPE insulated aluminium conductor armoured cable |
| 398 | Supply, laying, and testing of 4C x 16 Sq.mm 1.1kV grade FRLS XLPE insulated aluminium conductor armoured cable |
| 399 | Supply, laying, and testing of 4C x 10 Sq.mm 1.1kV grade FRLS PVC insulated copper conductor armoured cable |
| 400 | Supply, laying, and testing of 4C x 4 Sq.mm 1.1kV grade FRLS PVC insulated copper conductor armoured cable |
| 401 | Supply, laying, and testing of 4C x 2.5 Sq.mm 1.1kV grade FRLS PVC insulated copper conductor armoured cable |
| 402 | Supply, laying, and testing of 3C x 2.5 Sq.mm 1.1kV grade FRLS PVC insulated copper conductor armoured cable |
| 403 | Supply, laying, and testing of 2C x 2.5 Sq.mm 1.1kV grade FRLS PVC insulated copper conductor armoured cable |
| 404 | Supply, laying, and testing of 24C x 2.5 Sq.mm 1.1kV grade FRLS PVC insulated copper conductor armoured cable |
| 405 | Supply and fixing of brass cable gland for 3-1/2 x 400 sq.mm. PVC armouredLTUG cable with earth connection |
| 406 | Supply and fixing of brass cable gland for 3-1/2 x 300 sq.mm. PVC armouredLTUG cable with earth connection |
| 407 | Supply and fixing of brass cable gland for 3-1/2 x 185 sq.mm. PVC armouredLTUG cable with earth connection |
| 408 | Supply and fixing of brass cable gland for 3-1/2 x 150 sq.mm. PVC armouredLTUG cable with earth connection |
| 409 | Supply and fixing of brass cable gland for 3-1/2 x 120 sq.mm. PVC armouredLTUG cable with earth connection |
| 410 | Supply and fixing of brass cable gland for 3-1/2 x 70 sq.mm. PVC armouredLTUG cable with earth connection |
| 411 | Supply and fixing of brass cable gland for 3-1/2 x 35 sq.mm. PVC armouredLTUG cable with earth connection |
| 412 | Supply and fixing of brass cable gland for 4 x 25 sq.mm. PVC armouredLTUG cable with earth connection |
| 413 | Supply and fixing of brass cable gland for 4 x 16 sq.mm. PVC armouredLTUG cable with earth connection |
| 414 | Supply and fixing of brass cable gland for 4 x 10 sq.mm. PVC armouredLTUG cable with earth connection |
| 415 | Supply and fixing of brass cable gland for 4 x 4 sq.mm. PVC armouredLTUG cable with earth connection |
| 416 | Supply and fixing of brass cable gland for 3 x 2.5 sq.mm. PVC armouredLTUG cable with earth connection |
| 417 | Supply and fixing of brass cable gland for 2 x 2.5 sq.mm. PVC armouredLTUG cable with earth connection |
| 418 | Supply and fixing of brass cable gland for 4 x 2.5 sq.mm. PVC armouredLTUG cable with earth connection |
| 419 | Supply and fixing of brass cable gland for 24 x 2.5 sq.mm. PVC armouredLTUG cable with earth connection |
| 420 | Supply and providing cable end termination of 3-1/2 x 25 sq.mm. PVC LTUGaluminium armoured cable with necessary aluminium cable sockets bycrimping etc with electrical connection complete |
| 421 | Supply and providing cable end termination of 3-1/2 x 35 sq.mm. PVC LTUGaluminium armoured cable with necessary aluminium cable sockets bycrimping etc with electrical connection complete |
| 422 | Supply and providing cable end termination of 3-1/2 x 70 sq.mm. PVC LTUGaluminium armoured cable with necessary aluminium cable sockets bycrimping etc with electrical connection complete |
| 423 | Supply and providing cable end termination of 3-1/2 x 120 sq.mm. PVC LTUGaluminium armoured cable with necessary aluminium cable sockets bycrimping etc with electrical connection complete |
| 424 | Supply and providing cable end termination of 3-1/2 x 150 sq.mm. PVC LTUGaluminium armoured cable with necessary aluminium cable sockets bycrimping etc with electrical connection complete |
| 425 | Supply and providing cable end termination of 3-1/2 x 185 sq.mm. PVC LTUGaluminium armoured cable with necessary aluminium cable sockets bycrimping etc with electrical connection complete |
| 426 | Supply and providing cable end termination of 3-1/2 x 300 sq.mm. PVC LTUGaluminium armoured cable with necessary aluminium cable sockets bycrimping etc with electrical connection complete |
| 427 | Supply and providing cable end termination of 3-1/2 x 400 sq.mm. PVC LTUGaluminium armoured cable with necessary aluminium cable sockets bycrimping etc with electrical connection complete |
| 428 | Supply and providing cable end termination of 4 x 16 sq.mm. PVC LTUGaluminium armoured cable with necessary aluminium cable sockets bycrimping etc with electrical connection complete |
| 429 | Supply and providing cable end termination of 4 x 10 sq.mm. PVC LTUGcopper armoured cable with necessary aluminium cable sockets bycrimping etc with electrical connection complete |
| 430 | Supply and providing cable end termination of 4 x 4 sq.mm. PVC LTUGcopper armoured cable with necessary aluminium cable sockets bycrimping etc with electrical connection complete |
| 431 | Supply and providing cable end termination of 4 x 2.5 sq.mm. PVC LTUGcopper armoured cable with necessary aluminium cable sockets bycrimping etc with electrical connection complete |
| 432 | Supply and providing cable end termination of 24 x 2.5 sq.mm. PVC LTUGcopper armoured cable with necessary aluminium cable sockets bycrimping etc with electrical connection complete |
| 433 | Supply, installation, testing and commissioning of LT, 415Volts Sandwich type Copper Busbar Rising mains with all the wall bracket and fixing accessories etc., a)800A straight run feeder IP54 |
| 434 | Supply and installation of End Feed unit with 800Amps, 4Pole, 50kA Motorised type MCCB with OL & SC releases, operating rotary extended handle, adopter box, ON-OFF LED Lamps, flexible terminations (wherever required), etc., with all the fixing accessories |
| 435 | Supply and installation of Tap-off box with 160Amps, TP+N, 25kA, MCCB with Rotary handle and all the fixing accessories |
| 436 | Supply and installation of Tap-off box with 200Amps, TP+N, 25kA, MCCB with Rotary handle and all the fixing accessories |
| 437 | Supply and installation of Tap-off box with 250Amps, TP+N, 25kA, MCCB with Rotary handle and all the fixing accessories |
| 438 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with Module GI switch box in flush wall with 6A one way module switch with module front plate with painting of Suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for Open MS conduit Light point / fan point (for electronic regulator) ( 6 points / Coil) Higher End |
| 439 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for Open MS conduit Light point / fan point (for electronic regulator) ( 6 points / Coil) Higher End- Secondary Point Looping light points |
| 440 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLScopper conductor of 1100 V grade in suitable PVC rigid pipe Concealed inwall and ceiling with PVC accessories with Module GI switch box in flush withwall with 6A one way module switch with module front plate with continuousearth wire connection of 1.5 sq.mm copper wire and making good of theconcealed portion with suitable colour for Concealed PVC Light point / fanpoint (for electronic regulator) ( 4 points / Coil) |
| 441 | Wiring with 3 x1.5 sq.mm. PVC insulated single core unsheathed FRLScopper conductor of 1100 V grade in suitable PVC rigid pipe Concealed inwall and ceiling with PVC accessories with Module GI switch box in flushwith wall with 6A two way module switch with module front plate withcontinuous earth wire connection of 1.5 sq.mm copper wire and making goodof the concealed portion with suitable colour for Concealed PVC pipe Staircase Light point |
| 442 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe Concealed in wall and ceiling with MS accessories with suitable Module GI switch box in flush wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with painting of Suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for Concealed MS conduit Plug point (8points / Coil) Higher End |
| 443 | Wiring with 2 x4 sq.mm. PVC insulated single core unsheathed FRLS FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories with suitable Module GI switch box in flush with wall with 1 no. 16A one way module switch and 1 no. 16A/6A 3 pin module socket with module front plate with painting of Suitable colour with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for Concealed MS conduit 15A Plug point. ( 8 points / Coil) Higher End |
| 444 | Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable gauge MS conduit pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq mm copper wire and making good of the concealed portion |
| 445 | Supply and Run of 2 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable gauge MS conduit pipe concealed in wall and ceiling with continuous earth wire connection of 6 sq mm copper wire with painting of suitable colour. |
| 446 | Supply and Run of 2 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable gauge MS conduit pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq mm copper wire with painting of suitable colour |
| 447 | Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable gauge MS conduit pipe concealed in wall and ceiling with continuous earth wire connection of 2.5 sq mm copper wire and making good of the concealed position. |
| 448 | Supply and run of 2 of 1.5 sq.mm. PVC insulated SC unsheathed FRLScopper conductor of 1100V grade in rigid pipe concealed in wall and ceilingwith continuous earth wire connection of 1.5 sq.mm copper wire and makinggood of the concealed portion with suitable colour |
| 449 | Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copperconductor of 1100V grade in suitable PVC rigid pipe concealed in wall andceiling with continuous earth wire connection of 4 sq.mm copper wire andmaking good of the concealed portion with suitable colour |
| 450 | Supply and laying of (22 / 0.3) 1.5 Sq.mm FR-LSH multistrand Copper flexible wire with ISI mark IS 694 /1990in the existing conduit / raceways |
| 451 | Supply and laying of (36 / 0.3) 2.5 Sq.mm FR-LSH multistrand Copper flexible wire with ISI mark IS 694 /1990in the existing conduit / raceways |
| 452 | Supply and laying of (56 / 0.3) 4.0 Sq.mm FR-LSH multistrand Copper flexible wire with ISI mark IS 694 /1990 in the existing conduit / raceways |
| 453 | Supply and laying of 25mm dia. PVC Heavy duty conduit pipe with necessary bends,junction boxes, clamps, etc., (1.8mm thickness with ISI) |
| 454 | Supply and laying of 25mm dia. MS Conduit Pipe (1”) Heavy Gauge with necessary bends,junction boxes, clamps, etc., (16gauge with ISI) |
| 455 | Supply and erection of 3Phase, 6Way Vertical type VTPN MCCB Distribution board of IP43 double door type comprising of the followings:Incomer : 1 No. 100Amps, 25kA, 4Pole, MCCB Outgoings:4 Nos. 63Amps, TP MCB & 2 Nos. 40Amps TP MCBComplete with necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be readymade (powder coated type) fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc.,(Tenant Offices Main DB) |
| 456 | Supply and erection of 3Phase, 4Way Vertical type VTPN MCCB Distribution board of IP43 double door type comprising of the followings:Incomer : 1 No. 63Amps, 25kA, 4Pole, MCCB Outgoings:3 Nos. 40Amps, TP MCB & 3 Nos. 25Amps SP MCBComplete with necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be readymade (powder coated type) fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc.,(Aux. DB & Common Area Main DB) |
| 457 | Supply and erection of 3Phase, 8Way Vertical type VTPN MCCB Distribution board of IP43 double door type comprising of the followings:Incomer : 1 No. 125Amps, 25kA, 4Pole, MCCB Outgoings:4 Nos. 63Amps, TP MCB, 2 Nos. 40Amps TP MCB, 6 Nos. 25Amps, SP MCBs.Complete with necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be readymade (powder coated type) fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc.,(GF TPDB, Ventilation DB & PHE, EV Charging DB) |
| 458 | Supply and erection of 3Phase, 4Way, 7Segment type MCB Distribution board of IP43 double door type comprising of the followings:Incomer: 1 No. 63Amps, 4Pole, MCB with Timer + ContactorSub-Incomer : 3 x 25Amps, DP MCB Outgoings:12 Nos. 6/10/16/20Amps, SP MCBsComplete with necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be readymade (powder coated type) fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc.,(External LDB) |
| 459 | Supply and erection of 3Phase, 6Way, 7Segment type MCB Distribution board of IP43 double door type comprising of the followings:Incomer: 1 No. 63Amps, 4Pole, MCB Sub-Incomer : 3 x 25Amps, 30mA ELCB / RCCB Outgoings:18 Nos. 6/10/16/20Amps, SP MCBsComplete with necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be readymade (powder coated type) fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc.,(Tidel Office LDB, CA LDB (GF), CA LDB 1F-2F, CA LDB 3F-4F and Miscellaneous) |
| 460 | Supply and erection of 3Phase, 8Way, 7Segment type MCB Distribution board of IP43 double door type comprising of the followings:Incomer: 1 No. 63Amps, 4Pole, MCB Sub-Incomer : 3 x 40Amps, 30mA ELCB / RCCB Outgoings:24 Nos. 6/10/16/20Amps, SP MCBsComplete with necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be readymade (powder coated type) fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc.,(Tidel Office PDB, CA PDB (GF), CA PDB 1F-2F, CA PDB 3F-4F and Miscellaneous) |
| 461 | Supply and erection of 1Phase, 12Way SPN type MCB Distribution board of IP43 double door type comprising of the followings:Incomer: 1 No. 25A, 2Pole, MCB + 25A, 30mA DP ELCB/RCCBOutgoings:8 Nos. 6/10Amps, SP MCBsComplete with necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be readymade (powder coated type) fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc.,(ELDBs) |
| 462 | Supply and erection of 1Phase, 12Way SPN type MCB Distribution board of IP43 double door type comprising of the followings:Incomer: 1 No. 40A, 2Pole, MCB + 40A, 30mA DP ELCB/RCCBOutgoings:8 Nos. 6/10Amps, SP MCBsComplete with necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be readymade (powder coated type) fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc.,(SLDBs & ELDBs) |
| 463 | Supply and erection of 3Phase, 4Way TPN type MCB Distribution board of IP43 double door type comprising of the followings:Incomer: 1 No. 63A, 4Pole, MCB + 63A, 30mA 4P ELCB/RCCBOutgoings:9 Nos. 25Amps, DP MCBsComplete with necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be readymade (powder coated type) fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc.,(Main ELDB) |
| 464 | Supply and fixing of WT bulk head fitting with guard suitable with 7W / 9WLED bulb |
| 465 | Supply and fixing of 1200mm (48\") sweep AC ceiling fan 5 star ratedcomplete ( Higher end)with 2 module 100W fan step regulator (Higher end)with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18\") |
| 466 | Supply and fixing of 300mm (12\") sweep (light duty) AC exhaust fan completewithout provision of hole in the wall |
| 467 | Supply and erection of 4\" LED batten with wattage 18W and System Efficacy & System lumens of ≥110 lm / Wwith 2000 lm respectively. The type of LED shall be SMD type mounted on MCPCB which is mechanically fixed (no glue pasting) with CCT of 6500K and CRI > 80. The housing material shall be aluminium with polyester powder coating. The life of batten shall be 35000 hours at L70. The IP rating of the luminaire shall be IP20. The ambient temperature shall be 0-45deg C. The lumianire optical element shall be UV protected polycarbonate. The lumianaire shall be operable from 140 - 270V AC with PF > 0.9 and THD < 10%. The driver shall be encapsulated type and placed within the luminaire. The driver shall be with in-built surge protection of3kV. Drivers shall be flicker free and complies to IEEE P1789 standard. The effieciency of driver shall be > 90%. The luminaire shall be BIS approved and carry “R” number.Similar toSignify (Philips) Cat No. BN170C LED20S 6500 PSU L120 |
| 468 | Supply and fixing of 18W LED 3000K Round Type Recessed Fitting with with all the fixing accessories (20Watts) |
| 469 | Supply and fixing of 24W LED 4000K 2ft x 2ft Square Type Recessed Fitting with all the fixing accessories |
| 470 | Supply and fixing of IP20 LEDsurface mounted circular metal downlighter suitable for general lighting. Luminaire should have polycarbonate cover withdiffused optics. The luminaire should have CRI > 80, SDCM<5 and CCT of 6500K. The fixture should have a minimum system efficacy of 110 lumen/Watt(±10%)and a minimum system lumen output of 1500 lumens andsystem wattage of 13.5 Watts. The product shall have internal surge protection of 2.5kV. The luminaire shall be designed so as to ensure 50K burning hrs. @ L70 @ ambient temp 45 deg C. The electronic driver used shall have a power factor >0.9 , THD <10% ,similar to signify cat ref. SM296C LED15S-6500 PSU WH |
| 471 | Supply and fixing of 2\" LED batten (Mirror light) with Co-extruded polycarbonate housing and mounded end caps. The system wattage shall be 12W with system lumens of1200 lumens and system efficacy of100 lm / W. LED make:that satisfies IEC62471 Photobiological/RoHS Standards with,Colour Temperature-6500K or Higher with LED binning as per ANSI Bin C78.377A, 120Deg LED Beam Angle, CRI > 80, Life of LED as per L70 > 20000burning hours, Ambient temp-0 to 35DegC, Driver efficiency>85%, THD<30%, Power factor>0.9. similar to signify cat ref BN021 LED12S 6500 PSU GR |
| 472 | Supply and laying of LED Strip type light fitting with driver and all the fixing accessories(5Watts per Mtr). Similar to signify cat ref LS170S LED12 840 IP20 L5000 G2 |
| 473 | Supply and erection of 10W LED Up/down wall mounted fixture with 24 Deg Beam angle,Die cast housingand system efficacy100 lm/w, IP65, IK08,CCT 3000K, THD<5%, Surge 4KV. Similar to signify model no BWP102 LED10S 830 CYL 24D UP/DN GR |
| 474 | Supply and erection of 11Watts, 1000mm Height IP65 rated Bollard type light fitting with MS base, concreting and masonry work for fixing the post, connecting wires, and fixing accessories |
| 475 | Supply and erection of 12Watts, Round type Globe or circular pendent LED light fitting suspended from the ceiling with hanging supports, PVC unsheathed copper leads from terminals to the fitting . Similar to signify model Philips HDL 800051 |
| 476 | Supply and erection of 26W LED Postop made up of aluminium pressure die-cast aluminum with polycarbonate cover in addition to a specific weathering resistance treatment, Bigger Dia of 338 mm helps for uniform light distribution & Polycarbonate cover for glare-free light distribution, PDC spigot helps in sturdiness of product, Smooth finish Top cover, Robust Mounting base & Direct the light where it is needed to avoid sky pollution. High Efficiency long life LED module with SMD LED package mounted on MCPCB. Lumen Efficacy of LED>100Lm/W and CRI >70. Powered by Built In electronic. LED driver with THD<10%, 4kV inbuilt surge protection, high cut off at 325V, LV cut-off & HV Protection@440V for 8 hrs. System Lumen>4500 Lm, IP 65, IK 05, PF>0.95,Operating voltage range: 140 V - 270V, Average life L70B50: 50,000 hours.Both the fixture and Driver should be of same make & must have separate BIS approval. Similar to Signify Cat. Ref. No. BGP200 LED26 CW PSU GR CPC SPD |
| 477 | Supply, Erection of 8mtr Free Standing Single Arm Bracket8 sided Octogonally continously tapered structured pole with base plate of size 300 x 300 x 12mm as per IS-875 with following specification.Bottom Pole Dia - 130mmTop Pole Dia - 70 mmThickness of Pole - 3 mmThe pole should be hot dip galvanized confirming to BESNISO-1461 with thickness of 65 Micron |
| 478 | Supply, Erection of 8mtr Free Standing Double Arm Bracket8 sided Octogonally continously tapered structured pole with base plate of size 300 x 300 x 12mm as per IS-875 with following specification.Bottom Pole Dia - 130mmTop Pole Dia - 70 mmThickness of Pole - 3 mmThe pole should be hot dip galvanized confirming to BESNISO-1461 with thickness of 65 Micron |
| 479 | Supply and fixing of 120W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting . |
| 480 | Supply and Installation of 400KVA Diesel Generator Set with acousticenclosure conforming to CPCB IV+ Norms and BISSpecifications with standard control panel (Auto Start Stop facility) |
| 481 | Supply and Installation of Hot dipped galvanized / Powder coated type Ladder / perforated type Cable trays of following sizes, suspended from ceiling or fixed vertically on wall / column as per including necessary supports like anchor bolts, etc., and accessories like Elbows, Bends, Tee, required support / suspenders, hardware etc. as per site requirements.All the supporting structure & hardware including nuts & bolts and shall be of galvanized iron as approved. Height of cable tray will be 50mm and all the elbows, Bends, Reducers, Tees should be factory made.\"Ladder Tray is 2mm Thickness and Perforated Tray is 1.6mm Thicknessa) 750mm x 50mm wide GI Ladder type Cable Tray |
| 482 | Supply and Installation of Hot dipped galvanized / Powder coated type 600mm x 50mm wide GI Ladder type Cable Tray as mentioned above |
| 483 | Supply and Installation of Hot dipped galvanized / Powder coated type 450mm x 50mm wide GI Ladder type Cable Tray as mentioned above |
| 484 | Supply and Installation of Hot dipped galvanized / Powder coated type 300mm x 50mm wide GI Ladder type Cable Tray as mentioned above |
| 485 | Supply and Installation of Hot dipped galvanized / Powder coated type 300mm x 50mm wide GI Perforated type Cable Tray as mentioned above |
| 486 | Supply and Installation of Hot dipped galvanized / Powder coated type 150mm x 50mm wide GI Perforated type Cable Tray as mentioned above |
| 487 | Supply and Installation of Hot dipped galvanized / Powder coated type 100mm x 50mm wide GI Perforated type Cable Tray as mentioned above |
| 488 | Supply, installation, testing and commissioning of Lightning Protection System as per IEC 62305 standards |
| 489 | AIR TERMINATION SYSTEM |
| 490 | Supply and Installation of Aluminium alloy Solid Round Conductor with 8mm diameter of material AlMgSi as per IEC 62561-2 with suitable Conductor Holder, glue, connectors, joints etc.Test Parameter:a. Lightning impulse current of 100kA for 10/350 μsb. Electrical resistivity - 0.034 m,c. Tensile strength - 178 MPa or N/mm²d. Salt spray - No Sign of Corrosion.Tested as per IEC 62561-2.CAPE Type: SRC 8–AL(Article No. 400 008) |
| 491 | Supply and Installation of VAT 3mtr length of material AlMgSi of diametre ø 16/10mm crimped on both the ends (Tappered Type). The rod shall bemounted with stainless steel clamp and fixing accessories .Test Parameter for 3 mtr vertical air terminala)ELectrical Resistivityb) Tensile Strengthc) Condition of Salt MistTested as per IEC 62561-2.Test Parametrer for Wall clampa) Mechanical load as per IEC 62561-1CAPE Type: VATW3 (Article No. 405 420) |
| 492 | Supply and Installation of Lightning counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, Complies with IEC/EN 62561-6.CAPE Type No: PRO LER(Article No. 400 999) |
| 493 | Supply and Instalaltion of Stainless Steel 304 grade Test Joint with enclosure tointerconnect between 8 mm Al. round conductor to 10 mm copper bonded round conductor to meets the requirement of IS/IEC 62305 and IEC 62561-1Test Parameter:Mechanical loadEnvironmental Test for test joint plate -No sign of CorrosionLightning Impulse Current Tested as per IEC 62561-1CAPE Type: TJRRE - G1 (Article No. 404 214) |
| 494 | Supply and Installation of Rust resistant non corrosive 10 mm Dia Copper Bonded solid Steel round conductor used for Earth termination inside the concrete and soil. Meets the requirement of IS/IEC 62305.Test parameter:a) Short circuit current test for copper bonded conductor: Test 6.6kA ratings, as per cross sectional area for 1 sec (IS3043/IEEE80).b) Electrical Resistivity : 0.1 mc)Tensile strength 672 N/mm².d)Adhesion no peel or crack & Bend test no seperation of Cu,e) Cu Coating thickness min. 70μm.Tested as per IEC 62561-2.CAPE Type: SRC 10 CuB (Article No. 400 010). |
| 495 | Supply and Installation of Stainless steel 304 Grade Conductor Holder for fixing the 8 -10 mm dia round conductor on the wall to meets the requirementof IS/IEC 62305.Test Parameter:a) Mechanical Loadb) Environmental TestTested as per IEC 62561-4CAPE Type: CH 8-10 (Article No. 400 213) |
| 496 | Supply and Installation of CAPE make UL Listed Maintenance Free Copper bonded Earth rod of 3048mm length having the dia of 17.2 mm with copper coating thickness of 254 microns. The rod has been tested forDimension, Marking, Tensile Strength, environmental test, coatingthickness, Electrical resistivity test before and after corrosion test asper IEC 62561-2 & UL 467, including Earth Enhancement Mineral Compound used in areas with high soil resistance and rocky areas and tested for leaching and TCLP with NABL accredited Lab and electrical resistivity of soilt, Earth Chamber Inspection Pit made up of Plastic (PPGF) of outer dimension 290(L) x 290(W) x 209(H) withstand load of 60kN. Meets the requirement for IS/IEC 62305 and IEC 62561-5 |
| 497 | Supply, installation, testing and commissioning of On Grid Solar PV Plant from 11kwp to 100kwp comprising of:i) Solar panels of type Mono Crystline, PERC, etc.ii) Power Conditioning Unit (PCU)with MPPT, Inverter, Controls, ProtectionDevices, Interconnecting D.C. cables, Connectors, Junction Boxes andaccessories.iii) D.C. D.Biv) A.C. D.Bv) A.C. cables and accessoriesvi) Lightning arrestor, earthing, etc.The rate shall be inclusive of complete all accessories. (Make : Srivari / Vikram / Sri Nandhees) |
| 498 | Liaison with the Electrical Inspector to Govt., / CEA for preparation of Working drawings etc., obtaining approval for drawing. Preparation of completion Report. Arranging for inspection and attending to defects report and preparation of as fitted drawings and obtaining safety certificate from CEIG / CEA for commisioning the 25KW Solar system. |
| 499 | Supply, Installation, Testing & Commissioning of 3Phase input and 3Phase Output, 10kVA UPS modules with IGBT rectifier Isolation transformer and IGBT Inverter with SMF type Batteries for 2 Hours back up.The battery shall be of the sealed maintenance free Valve Regulated Lead Acid VRLA technology SMF batteries stationary C20 type. The complete battery system shall be flexible type such that one or more batteries are fail or under maintenance, the battery system shall be operated without power interruption. The quoted rate is inclusive of Interconnection copper cable between Battery & UPS and suitable size Battery stand. The batteries shall be similar to SMF VRLA sealed technology, self resealing, pressure regulated and explosion proof. Product conforms to IEC 60896. The battery offered shall have a minimum life of not less than 500 charge/ discharge cycles or 5 years from date of Practical completion certificate. |
| 500 | Supply, Installation, Testing & Commissioning of 1Phase input and 1Phase Output, 1x 5kVA UPS with IGBT rectifier Isolation transformer and IGBT Inverter with SMF type Batteries for 60 Minutes back up.VERTIV make Liebert ITA2 Model True On-line 1X5 KVA UPS System with Three –phase Input & Three Phase output 415 /50Hz. IGBT Technologies Features• Fully Digital highly reliable.• Higher Operation temperature• 0° to 50°.• Ll-ion battery compatible.• Operates in Parallel configuration upto 4 Nos.• Integrated SNMP for Monitoring. And MODBUS function.• In-built Isolation transformer External SMF Battery to provide for 60 Mins back upBattery Rating : 12 V/ 100 AH -40 NosBattery Make :Exide /HBLBattery rack and Interlinks cables and Battery cap with Battery isolator |
| 501 | Supply and installation of MS Structural steel supports with paint finishing including anchor fasteners, etc., for cable trays, DBs, and panels |
| 502 | Supply and erection of PIR Occupancy sensor (Motion) for Staircase area lighting control |
| 503 | SEWERAGE & RAIN WATER HARVESTING |
| 504 | EXTERNAL SEWERAGE |
| 505 | Supplying and Constructing Sewage collection sump I Well as per the following sewage holding capacity (after invert level of pipe - with a free board of mkinimum 750mm) including making earth work excavation, laying cement concrete in 1: 3: 6 mix for 250mm depth in foundation, providing and laying in position machine batched, machine mixed and machine vibrated design mix concrete of M25 grade RCC by using not less than 410 kg of cement and 250 kg of steel per cubic metre of concrete (sizes of structural members such as base slab side walls and cover slab shall be designed by the Contractor after making necessary site visits and studying the conditions at site and adopted after gettingapprovalfromtheEngineer-in-charge),includingfinishingby plastering with cement mortar 1:3 mix for inner surfaces, plastering outer surfaces in cement mortar 1:4 mix, 20mm thick,fixing and removing form work for shuttering to RCC works, providing and fixing two number of SFRC manhole cover and frame 600 x 600 size weighing 50 kg, 1No of 1200 x 1200mm size pre fabricated metal cover and frame (gas and water tight) with painting, suitable size screen made of stainless steel bars & plates as per the standard drawings, refilling the sides with excavated earth,disposing surplus earth with in the Site,bailing out the water from the excavation, conducting water test for leak proof construction by filling water to full depth of collecting well etc., Collection tankSize LxWxH 2000x1500x2000 mm |
| 506 | Supplying & Construction of inspection chambers of following sizes 60 x 60 x 60cm with earth work excavation for foundation, 23cm thick concrete bed using 40mm brick jelly concrete in C.M.1:5:10 for foundation, brick work in C.M.1:6 for chamber, plastering with C.M.1:3, 12mm thick, benching, channelling, supplying and fixing 45x45cm FRC cover and frame, etc., |
| 507 | Supply and fixing of conical manhole with 230 mm best quality approved table moulded bricks in CM 1:6, 560 mm dia at top and 900 mm dia at bottom over a bed of 250 mm thick PCC 1:4:8 walls plastered inside smooth in CM 1:3 and outside in CM 1:6, necessary excavation for the manhole in all sorts of soil including soft and hard rock, benching and channelling in PCC 1:2:4 as per drawing supply and fixing of frame and cover AAGMA make, CI steps etc., a) Depth of manhole 0.9 m to 1.65 mtrs |
| 508 | Supplying, fixing, testing and commissioning of ready made PVC gully trap (ISI brand only) of 300 x 300 mm size with 75 mm dia outlet. and also providing suitable size of cast iron grating, including 40 mm thick precastready made light duty RCC cover slab, clearing the surplus material, earth etc.,a) 300mm x 300mm size `P/S\" trap |
| 509 | Supplying and fixing SFRC manhole covers with frame (With holes) of following size confirming to IS 12592-HD20 Grade with clear opening size of 600 mm. The rate shall be inclusive of fixing frame with cement concrete, finishing, costof materials, labour, tools & plant, curing, consumables, leads and lifts at all levels, loading and unloading charges, transportation, all other incidental charges, providing provision for locking arrangement, etc. complete as per specification, drawing and as directed by Engineer-in-charge. The rates of cement concrete for fixing frame with necessary finishing shall be paid for separately under respective item a) 600mm X 600mm Heavy duty |
| 510 | Supplying and fixing CI manhole covers of approved size and make. The rate shall be inclusive of providing locking arrangement, finishing the surface with 2 coats of approvedZinc chromate primerand 2coats synthetic enamel paint of approved manufacture and color as per the specifications, fixing edge angle of size 40x40x5mm all-round the opening in cement concrete with necessary finishing, costof materials, labour, tools & plant, curing, consumables, leads and lifts at all levels, loading and unloading charges, transportation, all other incidental charges, etc. complete and as directed by Engineer-in-charge.a) Heavy Duty - weight of cover not less than 110 kg of 600X600mm size |
| 511 | Supplying and Installation of 200mm dia. RCC Hume pipes with collars for road / below floor crossing of Fire water pipes. Rate shall includePCC ( 1:4:8 100 mm thick)bed and ends shall be closed with Brick masonry work as directed by site engineers. |
| 512 | Supply and installation of SWR pipeSchedule 40 uPVC PIPES conforming to ASTM D-1785 and Fittings conforming to ASTM D-2466 (for Sch. 40 fittings). Joints to be made with uPVC solvent cement upto 50mm dia as per ASTM D-2564 and above 50mm dia primer P-70 and solvent conforming to ASTM D-2564. The quoted rate shall also include pipe with fittings, pipe to be laid below ground/ above ground/ fixed on walls, with necessary 10mm anchoring supports, brackets, threaded rods, threaded U-clamps, universal clamps, etc. spaced @ 1.5 mtr intervals, (all supports in walls shall necessarily be with Wall Brackets & Anchoring Bolts). The quoted rate shall include lead and lifting charges to all levels etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. Exposed pipes to be painted of legends with direction arrow, (color coding as per IS-2379) |
| 513 | 80 mm dia uPVC pipe |
| 514 | 150 mm dia uPVC pipe |
| 515 | SANITARY FITTINGS |
| 516 | Supplying and fixing in position White / Colour Special Delux Model Glazed Cascade Type Parryware / Hindware / Equivalent Wall Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using indian adopter jointincluding all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) with 10 litres capacity flushing tank with all internal dual flush fittings with normal seat cover Wall Fitting |
| 517 | Supplying and fixing of White Glazed Porcelain Oval ShapeSpecial Type Urinal of size 382 x 398 x 601mm |
| 518 | Supplying, installing, ofgranite (Jet Black) Urinal partitionsize 750mm x500 mm with 20mm thick of approved colour \"\"Pre polished both sides and edges madeto shape as per drawing, fixing with S.S \"\"U\"\" clamp and bolt,nut to wall complete etc. |
| 519 | Supplying & installing Wash Hand Basin of size 550mm x 400mm with all accessories such as Cast Iron Brackets, 32mm dia CP Waste Coupling, Rubber Plug and Chain, 32mm dia ‘B’ Class GI Waste Pipe, 15mm dia GM Wheel Valve, 15mm dia Nylon Connection, 15mm dia Brass Nipples, 15mm CP Pillar Tap etc |
| 520 | Supply, Fixing and testing of 15mm Stainless Steel Health faucet of approved make with necessary flexible hose 1000 mm long nozzle, wall flange etc.,complete. |
| 521 | Supplying, installing, testing and commissioning of CP exposed type Toilet paper holder with necessary screws etc., Paper HolderMake -TOTO / Kohler / Jaguar |
| 522 | Supply, Fixing, testing and commissioning of15 mm dia C.P. brass 2 way cock with C.P. wall flange of approved quality and making good as required. |
| 523 | Supplying,installing, testing and commissioning ofcp Double Coat hookfixing with necessary screws etc., complete |
| 524 | Supplying, installing, testing and commissioning ofliquid soap container of approved make near wash basins with necessary fixing screws and clamps etc.,Deals Stainless Steel Long Cylindrical SoapMake -TOTO / Kohler / Jaguar |
| 525 | Supply and fixing of Hand drier of approved make and colour having twin blower integrated with timer cum infrared sensing system fully automatic which can work on 230 volts, single phase, 50 cycles etc., High Speed Hand Dryer |
| 526 | Supplying, Installing, testing and commissioning of White color Floor Mounted European water closet with inbuilt low level PVC flushing cistern and Wash Basin for Physically Challenged Persons (Matrix) with necessary Grab Rails, hinged rails for support , pan connecter bend,checknut, stopcock etc., colour solid seat and cover with polythene buffer and flap, CP flanges, CP bolts and nuts, bracket with nuts and bolts wall flanges etc., complete, Wash Basin shall include 15mm dia CP liver operated pillar Cock / auto closing pillar tap withwaste coupling, 32mm dia CP bottle trap with extension pipe, supporting bracket with necessary steel to support basin 1 No.15mm CP angle valve with 450mm long CP connection pipe and CP wall flanges all of approved make etc., complete. |
| 527 | Close Coupled Toilet ( P Trap ) + Two Piece Toilet WithTank Lavatory 1 Tap Hole (for The Disabled Flip up Type Grab Bar w/ Lock T113HK7Straight Grab Rail - 600mm - Dia 34mm T113B6L Shaped Grab Bar Fixing Bolt (Set)Single lever lavatory faucet Waste Coupling& CP bottle trapMake -TOTO / Kohler / Jaguar |
| 528 | Supplying, installing, testing and commissioning of Soap dish holderof approved make nearshowerwith necessary fixing screws and clamps etc., complete. |
| 529 | Supplying, installing, testing and commissioning of 600mm x 600mm x 200mm stainless steel sink with Single bowl single drain of approved size manufactured from 1mm thick stainless steel, 18 G high grade indestructible chrome nickel steel with top quality polish, 40 mm dia CP waste coupling with extension flexible pipe of suitable dia. 15 mm dia angle cock, TEE joint with threated dummy, etc., complete. Supply and fixing of granite counter shall be done by the civil contractor |
| 530 | Supplying, installing, testing and commissioning of SS Modular wall mounted Drinking water dispenser (Fountain –Hot & cold both) of approved make at toilet core with necessary accessories and supporting screws and clamps etc., |
| 531 | Supplying and fixing Grab bar 450mm Long with necessary fixing accessories |
| 532 | Supplying andfixing Special Type Mirror of size 1000 x 780mm |
| 533 | INTERNALDRAINAGE |
| 534 | Supplying, fixing and testing UPVC SWR- B Classpipe of approved Makeconfirming to IS 13592-1992. and fittings confirming to IS 14735-1999, such as coupler, elbow, bends, Tee, Y, vent cowl etcfor Soil,Waste, vent and rain water pipe works in shaft and suspended in ceiling., laid in ground( from shaftto Inspection chamber and Gully chamber),etc., using rubber ring joints(rubber ring confirming to IS 15382) for shafts lines and solvent cement joints for suspended lines and work in below ground. Woks includes necessary scaffolding, cutting and making good the walls wherever required all complete as directed by Engineer. |
| 535 | 100 mm dia uPVC pipe |
| 536 | 80 mm dia uPVC pipe |
| 537 | 40 mm dia uPVC pipe |
| 538 | Supplying, fixing and testing ofUPVC/ PVC floor trapwith cockroach trap and CP grating 150 mm nominal size square 100mm diameter of the inner hinged round grating various inlet from 40 dia to 110 dia and various outlet from 75 dia to 100 dia with the extension pipe, boss tee connections, fixed in sunken floors/Suspended support with ceiling level etc., |
| 539 | Supplying, fixing and testing of UPVC floor clean out used in sunken floors,75 & 110mm dia with extension pipes,specils such as 45 degree bend , tee ,CP tile grating andend cap (clean out plug ).thecap arrangements with female thread fix with the upvc clean out plug in male thread with gasket ands.s screwsetc. complete.Works including cutting and making goodthe walls /floor wherever required,etc., complete. |
| 540 | 110 mm dia |
| 541 | 75 mm dia |
| 542 | INTERNAL WATER SUPPLY |
| 543 | Supplying, installing testing and commissioning of approved make chlorinated polyvinyl chloride pipe (CPVC) up to 50 mm dia SDR 11 ASTM CTS and above 50mm dia CPVCschedule 80 fittings. The fittings and specials such as tees, elbow, coupler, bends, enlarged etc., with CPVC brass thread combination /transition specials such as male adapters brass threaded female adopters, brass FPT tee, brass FPT elbow etc., where connection with metal is to be made including necessary hole drilling holes chasing wall and making the same good in cement mortar 1:1 restore the same original condition neatly as directed by the engineer in charge. Joint to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above 50 mm dia primer P-70 and solvent conforming to ASTM F- 4931 / 724 the rate shall be inclusive of all necessary suspended support and wall support with suitablebrackets clamp and bolt nut etc complete. |
| 544 | 20mm nominal outer dia. Pipe |
| 545 | 25mm nominal outer dia. Pipe |
| 546 | 32mm nominal outer dia. Pipe |
| 547 | 40mm nominal outer dia. Pipe |
| 548 | 50mm nominal outer dia. Pipe |
| 549 | 65mm nominal outer dia. Pipe |
| 550 | Supplying, installing, testing and commissioning approved make lever operated forged brass / Bronze Ball valves conforming to BIS/BS with brass body forged brass hard chrome plated steel ball tested to a pressure rating not less than 15 Kg / sqcm with threaded / flanged joints with nuts, bolts, gaskets, washers union etc complete . |
| 551 | 25 mm nominal bore |
| 552 | 32 mm nominal bore |
| 553 | 40 mm nominal bore |
| 554 | 50 mm nominal bore |
| 555 | Supply & Fixing in position control lever operated type PN 10 CI body butterfly valve with matching CPVC companion flanges asper table -\"E\",SS bolts, nuts, nitrile rubber gasket with necessary fittings etc., 65mm dia (Flange end) |
| 556 | Supplying &installing,Chrome plated forged brass body and cover Auto Air release valve fordomestic and flushing water supply risers, suitable for pressure not less than 15 Kg/Sq.cm.a) 25 mm nominal bore |
| 557 | Supplying, installing, testing & commissioning approved make forged brass Pressure reducing valve (PRV) with all accessories conforming to IS/BS with unions etc., a) 32 mm nominal bore |
| 558 | Supply & Fixing PN 16 CI Y strainers with perforated brass strainer body of approved make, provide each strainer with a cock for blowing down. Screen area of strainer shall be minimum of 5 times more than the pipe area with 1/32 inch max size holes. The cost also includes necessary fittings for supply and fixing to the pipes.a) 50mm dia (Screwed end) |
| 559 | Supply & Fixing Check valves. The body and plates are of CI body and pressure rating is PN 16. The valve seal is Neoprene rubber. The cost also includes necessary fittings to complete the connections. Please refer technical specification attached. with necessary fittings etc., complete50mm dia (Screwed end) |
| 560 | RAIN WATER HARVESTING |
| 561 | Supply & Fixing of (DWC HDPE) Double wall corrugated high density polyethylene ISO 21138-Part-1 & 3,EN 13476-1 & 3 soil, waste &all necessary specials like bends, tees, etc., laid under ground with necessary fittings etc., complete. For Under ground drainage systema) 160mm OD -SN8 |
| 562 | Supply & Fixing Class II (6 kg/cm2) rigid PVC pipes (for rain water down takes) with necessary specials like bend, shoe, grating, clamps, screws etc., including jointing the pipes and specials with solvent cement and cutting the pipes required lengths, with necessary fittings etc., complete at all heights and depths.a) 110mm OD |
| 563 | Supplying & Construction of inspection chambers of following sizes 60 x 60 x 60cm with earth work excavation for foundation, 23cm thick concrete bed using 40mm brick jelly concrete in C.M.1:4:10 for foundation, brick work in C.M.1:6 for chamber, plastering with C.M.1:3, 12mm thick, benching, channelling, supplying and fixing 45x45cm FRC cover and frame, etc., |
| 564 | Supplying and fixing SFRC manhole covers with frame (With holes) of following size confirming to IS 12592-HD20 Grade with clear opening size of 600 mm. The rate shall be inclusive of fixing frame with cement concrete, finishing, costof materials, labour, tools & plant, curing, consumables, leads and lifts at all levels, loading and unloading charges, transportation, all other incidental charges, providing provision for locking arrangement, etc. complete as per specification, drawing and as directed by Engineer-in-charge. The rates of cement concrete for fixing frame with necessary finishing shall be paid for separately under respective item a) 600mm X 600mm Heavy duty |
| 565 | Supplying and fixing CI manhole covers of approved size and make. The rate shall be inclusive of providing locking arrangement, finishing the surface with 2 coats of approvedZinc chromate primerand 2coats synthetic enamel paint of approved manufacture and color as per the specifications, fixing edge angle of size 40x40x5mm all-round the opening in cement concrete with necessary finishing, costof materials, labour, tools & plant, curing, consumables, leads and lifts at all levels, loading and unloading charges, transportation, all other incidental charges, etc. complete and as directed by Engineer-in-charge.a) Heavy Duty - weight of cover not less than 110 kg of 600X600mm size |
| 566 | Supplying and Constructing Rain water collection sump I Well as per the following sewage holding capacity (after invert level of pipe - with a free board of minimum 750mm) including making earth work excavation, laying cement concrete in 1: 3: 6 mix for 250mm depth in foundation, providing and laying in position machine batched, machine mixed and machine vibrated design mix concrete of M25 grade RCC by using not less than 410 kg of cement and 250 kg of steel per cubic metre of concrete (sizes of structural members such as base slab side walls and cover slab shall be designed by the Contractor after making necessary site visits and studying the conditions at site and adopted after gettingapprovalfromtheEngineer-in-charge),includingfinishingby plastering with cement mortar 1:3 mix for inner surfaces, plastering outer surfaces in cement mortar 1:4 mix, 20mm thick, fixing and removing form work for shuttering to RCC works, providing and fixing two number of SFRC manhole cover and frame 600 x 600 size weighing 50 kg, 1No of 1200 x 1200mm size pre fabricated metal cover and frame (gas and water tight) with painting, suitable size screen made of stainless steel bars & plates as per the standard drawings, refilling the sides with excavated earth, disposing surplus earth with in the Site, bailing out the water from the excavation, conducting water test for leak proof construction by filling water to full depth of collecting well etc. a) Collection tankSize LxWxH 4000x3000x2000 mm |
| 567 | Supply & Fixing PVC rain water Khurra, flashing including moulded bends, enlarger & leaf trap complete at each outlet. etc., Side outlet 110 mm OD |
| 568 | Supplying and installation of Precast Concrete Trench with top cover (900 X 800 mm) |
| 569 | Supplying, fabricating and erection of MS fabricated structural steel with 2 coats of red oxide primer & 2 coats of approved enamel paint (Total DFTminimum 120 micron) including all channels, box section, suspension supports, steel plate,cross angles, brackets, GI fasteners, anchor fasteners etc. including grouting, welding, tools, tackles as required etc. |
| 570 | PUMPS & WATER TREATMENT PLANT |
| 571 | Supply and installation of Electric Monoset centrifugal pump conforming to IS 9079:2002 as amended from time to time, with CI FG 200 Casing , hydraulically and dynamically balanced Bronze grade LTB-2 impeller, impeller ring and casing ring, stainless steel shaft capable of discharging required quantity of water against a total head noted below due to all causes. Pump shall of BEE 3 Star Rated and capable of discharging the specified quantity at the head noted at the minimum NPSHA at site conditions. The shut off head shall be at least 25% over and above the head at duty point. The pump shall be suitable for operation in AC three phase , 415 V+/- 10% , 50 Hz +/- 5%. Squirrel cage induction motor for continuous operation. The speed of the Pump and Motor shall be not less than 2700 to 2900 RPM respectively. Treated Water Pump (From Domestic Water Sump to O.H.T) Duty of Pump : 250 lpm x35m head (1 No. Working + 1 No. Standby) |
| 572 | Supply and installation of clear water vertical wet type submersible pump conforming to IS 8034/2002 and as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continuous rated two pole suitable wet type vertical squirrel cage induction motor suitable for operation in AC single phase 230 V+/- 10 %,50 HZ +/-5% Pumproom drain pumpDuty of Pump : 15lpm x 40m head (1 No. Working ) |
| 573 | Supplying, Installing, testing & commissioning approved make variable Hydropneumatics system comprising of Vertical Centrifugal pumps mounted on a common skid with automatic control panel including overload relays, on-off push button switches, phase indicator lamps, dry run protection relays, pressure switches & gauges, 1no. FRP pressure vessel of 425Lts. mounted on the pump complete with cabling between the Pumps, control panel etc., complete. The pumps shall run on 440V, 3ph, 50Hz electric supply. (For flushing & landscaping water supply system) Duty of Pump : 67 lpm @ 45.0m Head Each Pump capacity 67 lpm - 2 pump system (1Working+1 Standby) |
| 574 | Supply, Installation & Commissioning of rain water monobloc type pump of adequate HP capable of giving required discharge at suitable head to work on 3phase 50Hz 400/400 V with necessary unions, flanges, foundations bolts etc., complete with head conditions. (1W+1S) |
| 575 | WATER TREATMENT PLANT 14.50 KLD (Capacity 2500 LPH) IN PUMPROOM |
| 576 | Supplying, Installing, testing & commissioning of Water Treatment Plant(WTP_ of 2500LPH capacity comprising of below units Filter Feed Pump 1 no. - Horizontal Monobloc centrifugal pump Capacity: 2500LPH Head 25mMake: Kirloskar/EQPressure Sand Filter 1 no.- Size: 12”x 52” MOC: FRP with 25 NB Multiport valve Filtering media : Pebbles, Sand Operating Pressure : 3 Kg/Cm2 Make : Pentair/AventuraHypo Dosing tank 1 no.- Capacity: 50 Ltr. MOC: HDPE Make: Cantax / EQ Hypo Dosing Pumps 1 no. - Capacity: 0-4 LPH Make: Veritose/EQActivated Carbon filter 1 no. - Size: 12”x 52” MOC: FRP with 25 NB Multiport valve Filtering media: Pebbles, Carbon Operating Pressure : 3 Kg/Cm2 Make : Pentair/AventuraSoftener filter 1 no. - Size: 16”x 65” MOC: FRP with 25 NB Multiport valve, Filtering media : Resin OBR once in 8 hrs Operating Pressure : 3 Kg/Cm2Make : Pentair/AventuraRegeneration tank 1 no. - Capacity : 50 litre Make : CantexUPVC Pipes and Fittings As per requirement Make : Astral/Price/Supreme Starter, Cable, and accessories - As per requirement |
| 577 | RO WATER TREATMENT CAPACITY 250 LPH (1,000 Litre Storage) at Terrace |
| 578 | Supplying, installing, testing and commissioning approved make RO UNIT of 250 LPH comprising of below units: The quoted rate shall also include necessary RO filter membranes, valves, pipes, electricals etc., complete to make the operation automatic. RO Feed Pump. 1no. working - Type : Horizontal Monobloc centrifugal pump Capacity: 1.5 m3/hr Head 30m Make: Kirloskar/EQ Dual Media Filter 1 no. Size : 10 “ x 54” MOC : FRP Make : Pentair/EQ With Media and multiport valveMicron Filter with housing - 2 nos. Size: 20\"\" Housing MOC : PP Make: Gopani/EQ Antiscalant Dosing System - 1 no. Pump Capacity: 0-4 LPHMake: Veritose/Eq Dosing tank : 50 L, MOC: LDPE Make: Cantax / EQSMBS & Acid Dosing System Pump - 1 no. Capacity: 0-6 LPH Make: Veritose /EQ dosing tank : 50 L, MOC: HDPE Make: Cantax / EQHigh Pressure Pump - 1 No. Capacity: 1m3/hr Head : 120m Type : Vertical inline multistage Make: CRI/EQReverse Osmosis Membrane - 1 Lot Size: 8” x 40” Make: Hydranautics /Toray /EQ Membrane housing - 1 Lot Pressure rating – 300 PSI, MOC : FRP, Make: UKL/EquCIP Pump with tank - 1 No. Chemical Cleaning pump, 2.0m3/hr @ 25m head, CIP Tank 100 Liters, Power: 0.5 HP, MOC:SS, Make: CRI/KirloskarRO skid –MS Epoxy painted - 1 No. MS Powder coatedUPVC Pipes and Fittings - 1 LotAs per requirement Make : Astral/Price/Supreme Float switch - 1 LotAs per requirement Make : UKL/Aster/EQRotameter - 2 nos. Acrylic type Make : UKL/Aster/EQPressure switch - 1 Lot Low and high pressure switch Make : Danfoss/EQ RV control panel - 1 Lot Make : RV Associates / EQPressure gauge - 1 Lot Make : H guru/EQElectrical Cabling - 1 phase - 1 LotType : Flexible cable No. of Cores : 3 Core MOC : Copper Multi core Make : Poly cab / EQ |
| 579 | SEWAGE TREATMENT PLANT (STP - 25KLD) |
| 580 | Supplying, installation, testing and commissioning of STP ELECTRO-MECHANICAL EQUIPMENTS (Capacity 25 KLD - MBBR TYPE)Parameters :Quality of Raw Sewage in Mg/lCOD ≤ 600SS ≤ 300BOD ≤ 400 pH - 6 to 8, Treated Water standard achieved by the STP process in Mg/l COD ≤ 150SS ≤ 20 BOD ≤ 20 pH - 6.5 to 8, Raw Sewage Source - STPSupplying, installing, testing and commissioning of Bar screen - 1 no. Type: Manual typeMOC: SS 304,Raw Sewage Transfer Pumps - 2nos. ( 1 working + 1 stand by) Type: Submersible pump MOC: CI Make: Kirloskar/CG/EQ Power: 2.0 HP Raw Sewage Transfer Pumps - 2nos. ( 1 working + 1 stand by) Type: Submersible pump MOC: CI Make: Kirloskar/CG/EQ Power: 2.0 HPAeration tank - 1 no. Volume: 6000 Liters MOC: FRP. Settling cum Intermediate Tank - 1 no. Volume: 3400 Liters MOC: FRP Settling cum Intermediate Tank - 1no. Volume: 3400 Liters MOC: FRP Sludge Recirculation Pumps- 1 no. Type: Self Priming pump Power: 0.5 HPMake: Kirloskar/EQ Air Blower with motor - 2nos. ( 1 working + 1 stand by) Air flow: 30 m3/hr Make: Airvak/EQ Diffuser - Coarse1 Lot Type: Disc Air flow: 6 m3/hr (80mm dia) MOC: EPDM Diffuser – Fine for Aeration tank – 1 Lot Type: Fine Bubbl, Air flow: 6 m3/hr (63mmx610mm), MOC: EPDM, Make: Proflex/EQChlorine Dosing Pumps - 2nos. ( 1 working + 1 stand by) Capacity : 0-4 LPH @4 Kg/cm2, MOC: PP, Make: Edose/EQDosing Tank - 1 no. Capacity:50Ltrs,MOC:LDPEFilter Feed Pumps - 2nos. ( 1 working + 1 standby) |
| 581 | Supplying, installation, testing and commissioning ofMonobloc pump Power: 1.0 HP Make: Kirloskar/ EQPressure sandfilter with sand media - 1 no Model No.: 12 x 54, MOC: FRP with media and MPV, Make: Fibro Tech /Pentair/EQDiffuser – Fine for Aeration tank – 1 Lot Type: Fine Bubble, Air flow: 6 m3/hr (63mmx610mm), MOC: EPDM, Make: Proflex/EQActivated carbon filter with media - 1 no Model No.: 12 x 54 MOC: FRP with media and MPV Make: Fibro Tech /Pentair/EQBacterial bio culture 1 Lot [patented] Bio balls [Patented] - 1 Lot MOC: PP MS Structure1 Lot Make: Shank/EQAir Piping 1 Lot MOC: MS Make: Jindal Pipes / Tata/EQ Pipes & fittings - 1 Lot MOC: UPVC Make: Finolex / Astral/EQ Valves & Accessories - 1 LotMake: Orbit/EQLaunder for settling tank 1 No.MOC : FRP Parallel plate[Patented] 1 Lot MOC : PVCElectromagnetic flow meter 2 Nos. Make : Aster /EQ at STP inlet & outlet |
| 582 | HEAT, VENTILATION & AIR CONDITIONING |
| 583 | Supplying, installation, testing and commissioning ofVRF Outdoor units consists of 100% inverter scroll compressor / Twin Rotary compressors, DC fan motor with aero-spiral fan blade, e-pass heat exchanger, safety valves, solenoid valves, receiver, capillary tube, check valve, electronic expansion valve, high pressure switch, low pressure sensor, pressure regulating valve, refrigerant filter, stop valve, accumulator and refnet kits.The Rate shall be inclusive of R-410A refrigerant & oil pre charging, vibration isolators, supports, necessary foundation / pedestal works, elbow duct/cowl piece, suitable power cable from isolator to VRF ODU each module (7.5 RMT) etc.. The VRF ODU shall be compatible for BMS integration. |
| 584 | The below mentioned ODU capacities are the minimum Cooling Capacity required at the following conditionsa. 100% load condition b. 42 degC ambient condition c. All IDUs are in operating condition d. Design indoor temperature - Office area : 23 degC. RH shall not exceed 60%.The vendor to propose the suitable ODU considering the ambient deration. The VRF data sheet & ISEER data sheet shall be filled and submitted by the Vendor with the proposed VRF ODU capacity. The proposed VRF ODU capacity shall be approved by Client & Consultant before procurement. |
| 585 | Below Mentioned more than 18 HP ODU Models should be able to make module combination |
| 586 | (Approved Makes : Daikin,Hitachi,Toshiba) |
| 587 | 8HP VRF ODU |
| 588 | 10 HP VRF ODU |
| 589 | 12 HP VRF ODU |
| 590 | 16 HP VRF ODU |
| 591 | 18 HP VRF ODU |
| 592 | 30 HP VRF ODU |
| 593 | Supplying, installation, testing and commissioning of Wall Mounted Type Metallic body BMS Compatible VRF Indoor air conditioning units with direct driven fan, Evaporator coil, high efficient filter, inbuilt microprocessor thermostat, electronic expansion valve, provision of fresh air duct connection, necessarysupports & vibration isolators, R410A refrigerant charging, Refnet joints (Refrigerant branch kit) forboth liquid and gas line branch kits, oil charging, power cabling from nearest socket(7.5 RMT), control wiring and drain connection, etc. The capacities are as mentioned below:- (Approved Makes : Daikin,Hitachi,Toshiba) |
| 594 | 1.3 TR |
| 595 | Supplying, installation, testing and commissioning of Ceiling Suspended Cassette Type Metallic body BMS Compatible VRF Indoor air conditioning units with direct driven fan, Evaporator coil, high efficient filter, inbuilt microprocessor thermostat, electronic expansion valve, provision of fresh air duct connection, drain pumps for casette, necessary ceiling supports & vibration isolators, R410A refrigerant charging, Refnet joints (Refrigerant branch kit) forboth liquid and gas line branch kits, oil charging, power cabling from nearest socket(7.5 RMT), control wiring and drain connection, etc. The capacities are as mentioned below:- (Approved Makes : Daikin,Hitachi,Toshiba) |
| 596 | 1.6 TR |
| 597 | 2.6 TR |
| 598 | Supplying, installation, testing and commissioning of Ceiling Suspended Duct Type Metallic bodyBMS Compatible VRF Indoor air conditioning units with direct driven fan, Evaporator coil, high efficient filter, inbuilt microprocessor thermostat, electronic expansion valve, remote,provision of fresh air duct connection, drain pumps for casette, necessary ceiling supports & vibration isolators, R410A refrigerant charging, Refnet joints (Refrigerant branch kit) forboth liquid and gas line branch kits, oil charging, power cabling from nearest socket(7.5 RMT), control wiring and drain connection, etc. The below capacity units are OEM units and the capacity are as mentioned below:- Approved Makes : Daikin,Hitachi,Toshiba |
| 599 | 4.5 TR -ESP 20mm |
| 600 | 6.4 TR-ESP 20mm |
| 601 | 8.0 TR-ESP 20mm |
| 602 | SITC of Double Skin Floor mounted Air Handling Units as per the specifications.The AHU shall be 45±5mm thick panel with PUF insulation, thermal break profile, filter section with MERV 8, min 4 row deepDX Cooling coil of copper tube & aluminium fins, copper header, plug fan with EC motor,limit switch, light, inspection glass, spring vibration isolator for fan and motor, factory assembled volume control damper, internal power and control wiring, required length of power cable from the panel to the equipment, GI base frame complete as per specification required. AHU noise level shall be less than65dBA at 1.5m distance.Fan motor shall be suitable for 415±10% volts, 50 cycles, 3 phase AC supply. The AHU shall be provided with suitable rating starter panel and components. The electrical panel shall have incoming breaker, single / Multiple outgoing breakers, speed controler, indication lamp, contactor, auto / manual switch, necessary relays,potential freecontacts to be interlocked with fire alarm control module to trip the AHU incase of fire. The electrical starter panel shall have necessary relay, and potential free contacts for the following BMS provisions : (1) Auto / Manual command, (2) Auto/ Manual / OFF status, (3) Run status, (4) Trip Status. (Make : VTS / Flaktwood / Edgetech /System Air / luftec) |
| 603 | Capacity: 24 TR, Dehumidified Air: 7200 CFM, ESP: 25mmWC, |
| 604 | Capacity: 12 TR, Dehumidified Air: 4000 CFM, ESP: 25mmWC, |
| 605 | Supply, installation, testing and commissioning of Valve Kit for AHU & CSU |
| 606 | Supply, installation, testing and commissioning of AHU 3.7 KW VFD starter panel for FM AHU\"s with BMS compatibility. The starter panel capacity is as per AHU manufacturer recommendations. |
| 607 | Supply, installation, testing, and commissioning of Imported fittings Y-joints, distributor and headers for all Indoor units as per layout drawings. |
| 608 | Supply, installation, testing and commissioning of Corded/Cordless Remote controllersfor operation of indoor units |
| 609 | SITC Main controller BMS interface Modbus /bacnetIP for thrid party system integration,software andlicence key,communication cables, basic functions like ON/OFF, mode settings, temperature setting, fan speed setting, louver setting, timer, scheduling, holiday mode setting, error code, alarm, emergency trip, sensors etc. |
| 610 | Supply,Installation,testingandcommissioningincluding vaccumiazationandNitrogentestingoffollowingnominalsizesof soft/hard drawn copper refrigerant piping for VRV/VRF system, completewithfittings,withsuitable size cable tray/adjustableringtypehanger supports, jointing/brazing including accessories, insulated with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given belowforSuctionandLiquidlines &cladded with 26Galuminium sheet.allaccessoriesasper specifications etc. as required |
| 611 | All connections of Refrigerant piping shall be in high grade Copper of Refrigeration quality with Eddy Current Testing and material test Certificates. |
| 612 | For individual Piping 50 / 100 mm wide Aluminium Tape shall be used at joints of Piping with Bands for identification. |
| 613 | 44.5 mm O.D. (insulation : 19 mm) |
| 614 | 38.1 mm O.D. (insulation : 19 mm) |
| 615 | 34.9 mm O.D. (insulation : 19 mm) |
| 616 | 28.6 mm O.D. (insulation : 19 mm) |
| 617 | 25.4 mm O.D. (insulation : 19 mm) |
| 618 | 22.2 mm O.D. (insulation : 13 mm) |
| 619 | 19.1 mm O.D. (insulation : 13 mm) |
| 620 | 15.9 mm O.D. (insulation : 13 mm) |
| 621 | 12.7 mm O.D. (insulation : 13 mm) |
| 622 | 9.5 mm O.D. (insulation : 13 mm) |
| 623 | 6.4 mm O.D. (insulation : 13 mm) |
| 624 | Supply,installation,testing and commissioning of UPVC drain piping complete withfittings, supportsas perspecifications anddulyinsulatedwith9 mmthick closed cell elastomeric nitrile rubber or XLPE cladded with 26Galuminium sheet. |
| 625 | 25 mm ID |
| 626 | 32 mm ID |
| 627 | 40 mm ID |
| 628 | 50 mm ID |
| 629 | Supplying, installing, testing and commissioning of Shielded control cum transmission wiring of 2 core x 1.5 sqmm copper FRLSH, XLPE insulated cable in suitable GI conduits accessories between indoor and outdoor units. Necessary securing of conduit shall be made by contractor. After completion of work wall and floor shall be repaired and brought to its original finish. The rate will also include cost of laying of GI conduit between indoor and outdoor units. |
| 630 | 2C x 1.5 Sq mm (Unarmoured) |
| 631 | Providing additional R410A gas charging for the ODU units |
| 632 | Supply and Installation of Hot dipped galvanized / Powder coated type perforated type Cable trays of following sizes, suspended from ceiling or fixed vertically on wall / column as per including necessary supports like anchor bolts, etc., and accessories like Elbows, Bends, Tee, required support / suspenders, hardware etc. as per site requirements.All the supporting structure & hardware including nuts & bolts and shall be of galvanized iron as approved. Height of cable tray will be 50mm and all the elbows, Bends, Reducers, Tees should be factory made.\"Ladder Tray is 2mm Thickness and Perforated Tray is 1.6mm Thickness |
| 633 | 100mm wide 50mm height -Perforated acble tray |
| 634 | 150mm wide 50mm height -Perforated acble tray |
| 635 | 300mm wide 50mm height -Perforated acble tray |
| 636 | 450mm wide 50mm height -Perforated acble tray |
| 637 | Supply, installion, testing and commissioningof Inverter type DX coil Hi Wall Split Type Air-conditioning Unit (indoor). Indoor unit shall be complete with evaporatorcooling coil, Pre-filter, DIDW Fan with Direct driven motor. The unit shall be suitable for 230 ± 10% volts, 50 cycles/ second, single Phase AC supply. alongThe quoted price shall also include refrigerant charge, 5.0 KVA Voltage stabilizer of reputed make, Power Cabling, corded remote & Drain Pump, The unit shall be equipped with interface control module for controlling the unit.Chennai Ambient Condition with 5Star Rating units . |
| 638 | 1.5 TR |
| 639 | SITC Inverter DX Ceiling Suspended Cassette Type with eco friendly refrigerant units of following capacities. The Indoor unit shall comprise of Blowers, Cooling coil, Filter and Expansion device and drain pan,drain pumps and eco friendly refrigerantetc. The Outdoor unit shall comprise of Inverter Compressor, Wireless remote controller for Indoor units, Air cooled condenser & Condenser fans. Rate inclusive of 5kva voltage stabilizer, refrigerant charging, power cable-(7.5 RMT) from the panel/isolator/power socket point to indoor unit including plug top, supports for indoor units and outdoor units etc.The rate shall be inclusive of Insulated drain pipe and Ref.copper pipes |
| 640 | 2.0 TR |
| 641 | Supply, Installation, Testing and Commissioning of Timer and temperature based auto sequential control panel to sequence the operation of various indoor units. The sequential panel for unit with minimum 2.4 inch digital disply controller. The Controller should automatically start & stop the airconditioning unit as per the required schedule.In case of failure of any unit and the standby unit should take over the load with alarm. In case the operating unit is unable to maintain / achive set temparature the standby pump should also operate till the set temparature is achieved . In case of power failure as soon as the power is reinstatated , both the units should operate till the set temparature is achived and thereafter operate as per normal logic. The panel shall be suitable for third party integration like BMS compactible. |
| 642 | Supply, installation, testing and commissioning of condensate drain pump should be manufactured from rigid PVC suitable to hi wall unit. The quote price shall include 25mm dia. PVC pipe insulated with 9mm thick closed cell nitrile rubber (Class-O) interconnecting piping from unit to the nearest drain line, the vendor should include the necessary mounting arrangement for the pumps. ASPEN Pump |
| 643 | Supply, installing, testing, commissioning & handing over of double skin of cabinet type unit complete with squirrel cage induction motor, with belt drive arrangement. Motor shall be suitable for 415 + 10% volts, 50 cycles AC supply with AMCA certification complete for fan section with DIDWforward curved impeller. Flexible layer canvas connection shall be provided at the outlet of unit Fan. The Exhaust unit shall be selected for lowest operating noise level. Along with Exhaust air Unit, its starter panel with inclusive of cable from Panel to exhaust unit, with all other accesories required.Note: Only incoming feeder to be provided by Electrical contractor. Starter panels are in HVAC contractor scope. |
| 644 | 2100 CFM with 25 mm static Pressure - Toilet Exhaust air fan (IE3 motor) |
| 645 | 4250 CFM with 25 mm static Pressure - Toilet Exhaust air fan (IE3 motor) |
| 646 | 3250 CFM with 25 mm static Pressure - Toilet Exhaust air fan (IE3 motor) |
| 647 | 3000 CFM with 25 mm static Pressure - Elec room Ex.fan (IE3 motor) |
| 648 | 1000CFM with 20 mm static Pressure - Fresh air fan with pre-filter arrangements.(IE3 motor) |
| 649 | Supply, Installation, Testing, Commissioning of Vane Axial Type pressurization Fans Motor KW: As per OEM standardNo of Poles: 4 Pole1. The pressurization Fans are designed for ambient Temperature2. Direction of Discharge and Rotation shall be marked on the fan assembly, Impeller should aerodynamic Profile & Outlet Velocity Below 16m/s 3. Motor characteristic. - 415+_ 10%, 50 HZ, 3 Phase 4. Noise criterion-80 dba at 3 meter (computerized fan selection).5. Motor efficiency -(IE 3)6. Fan efficiency - minimum 60%Note:Axial fan Impeller dia to be as per manufacturing standards.Fans Shouild be AMCA Certified for both air flow & noise.Spring isolator to be provided for fan.Scope of Supply: Axial Fans with Bird Screen (1 No.) with all necessary supporting arranagement.Along with pressurization Fans , its starter panel with inclusive of cable from Panel to exhaust unit, with all other accesories required.Note: Only incoming feeder to be provided by Electrical contractor. Starter panel are in HVAC contractor scope. (Make : Kruger / Maico / Greenheck) |
| 650 | 7000CFM with 25 mm static Pressure- Pressurization fan |
| 651 | 10000 CFM with 25 mm static Pressure- Pressurization fan |
| 652 | Supply, installation, testing and commissioning of propeller type direct drive fan, heavy duty wall mounted type complete with gravity louvers, motors, mounting brackets,, 5A plug top and required cables from nearby power socket, 600x600x20mm thick marine plywood with hole to suit impeller dia, mounting supports and other standard accessories as per specifications and suitable for operation 230 +/- 10%V, 50Hz, 1 Phase AC supply.(Make : Kruger / Maico / Greenheck) |
| 653 | Air flow rate : 150 CFM |
| 654 | Supply, installation, testing and commissioning of Ventilation fan circular/ cabinet type units. The unit shall be 0.6mm GIS construction, direct / belt driven centrifugal fan, High efficiency motor with IP21 protection, spring vibration isolator for fan and motor, Fire retardant canvass connections, with acoustic enclosure for fan & noise level not exceed 65 dBA at 1.5m distance, internal power and control wiring, GI base frame complete as per specifications as required. Fan motor shall be suitable for 230V, 1 phase, 50Hz AC supply.Rate shall be inclusive of Suitable power cable from isolator to equipments (7.5 RMT approximately).(Make : Kruger / Maico / Greenheck) |
| 655 | Air Qty: 650 CFM, ESP: 10mmWC for Toilet ventilation |
| 656 | Air Qty: 420 CFM, ESP: 10mmWC for Toilet ventilation |
| 657 | Air Qty: 850 CFM, ESP: 10mmWC Toilet ,GF kitchen & Terrace Eec room ventilation |
| 658 | Air Qty: 1500 CFM, ESP: 10mmWC for Fire pump room Ventilation |
| 659 | Air Qty: 2500 CFM, ESP: 10mmWC for Electrical substation Ventilation |
| 660 | Supply, installation, testing and balancing of Air Distribution Systemconsists offactory fabricated sheet metal ductingcomplete with supports (anchor fasteners and tie-rods, cradles, angle iron supports, GI bolts and nuts, 4mm thick self-adhesive neoprene rubber gasket, stiffeners, zinc chromate painted angle iron flanges, chipping and plastering of openings made for duct supports etc., complete as per specification.The rates quoted shall include turning vanes,straighteningvanes,splitters,inspection doors probe, inlets with test openings enclosures complete with locking caps, chain, gaskets,etc. |
| 661 | 1.2 mm thick GSS ducting (18G) – factory fabricated |
| 662 | 1.0 mm thick GSS ducting (20G) – factory fabricated |
| 663 | 0.8mm thick GSS ducting (22G) – factory fabricated |
| 664 | 0.63mm thick GSS ducting (24G) – factory fabricated |
| 665 | Supply, Installation, Testing & Commissioning of air distribution system consists of factory fabricated GI sheet Flat Oval (elliptical) duct with pre insulated 13 mm thickness nitrile rubber FM approval factory made fittings like bends, tees, wire hanging support with crimp arrangement supports, spacing and fixing as per SMACNA standards. The rate shall be inclusive of powder coating (Mat finish) for the ducts as per the approved colour shade by Client / Architect. |
| 666 | 1.0 mm thick GSS ducting (20G) – factory fabricated |
| 667 | 0.8mm thick GSS ducting (22G) – factory fabricated |
| 668 | 0.63mm thick GSS ducting (24G) – factory fabricated |
| 669 | Supply and installing of Acoustic insulation, Material shall be FM approved Nitrile Rubber foam. The material should be fibre free. The density of the same shall be within 140-180 Kg/m3.The material should have a thermal conductivity Not exceeding 0.038 W/mK. The maximum surface temperature the material should withstand is 105º C and minimum temperature should be -20ºC. The Thickness of the material shall be 15mm. The material should conform to Class 1 rating for surface spread of Flame as per BS 476 Part 7.As per specification. |
| 670 | Supply and installation Thermal insulation on ducts with Class \"O\" Closed Cell Elastomeric 9mm thick Nitrile Rubber/XLPE with density of 40 - 60 kg/cum as per the thickness mentioned below, with fire retardant adhesive and joints sealed with 3mm thick, 50mm wide nitrile rubber self adhesive tape in accordance with the approved shop drawings and technical specifications. Quoted price shall be inclusive of adhesive, tapes, etc. |
| 671 | Supply and fixing of Under deck insulation with make it as XLPE insulation - 25 mm thick with density of 40 - 60 kg/cum as per the thickness mentioned fixed to the soffit with the help of plastic expansion fasteners. The plastic expansion fasteners is coupled with plastic wheel to support Polyurethane slabs. The fasteners are fixed at an interval of 500 C/C |
| 672 | Supply and erection ofpre fabricated wall acoustic Insulation for AHU Room with 50mm thick & 48kg/cm2 density glass wool with GI frame grid and covered with22 G perforated GI sheet with all accessories and supports. Etc |
| 673 | Supply and installation of GI volume controldamper low leakage( handle type ) made out of 1.6mm thick galvanised sheet steel frame and opposed blades of 1.6mm galvanised steel with suitable links, handles, levers and quadrants for manual control of volume of air flow and for proper balancing of air distribution system.as per specification |
| 674 | Oval. |
| 675 | Rectangular |
| 676 | Supply,installation, Testing and Commisioning of GI Motorised smoke and Fire Dampers Tested and Certified by CBRI Roorkee for 120 minutes fire rating as per UL 555/1995 Standards 16G Outer Frame 16G 3V Grooved Blades With Extended 450 mm Sleeve without Actuator |
| 677 | MOTORISED SMOKE AND FIRE DAMPER ACTUATOR CONTROL PANEL :Design, Manufacture, Supply, Installation, Testing, and Commissioning of Fire damper control panel, the control panel shall be capable of operating dampers based on fire input from FAS panel for auto operation and fire damper shall have the provision for monitoring actuator status through BMS. The multiple fire damper actuator shall be connected and controlled through single control panel. The vendor shall provide the local display with reset option. Vendor shall ensure that the control panel shall be compatible for output voltage of 220V. During fire mode fire damper will get signal from Fire panel to close the damper. Provision for fire input shall be considered in the fire damper control panel and AHU starter panel.Vendor shall consider Power cable of minimum 1.5 meter with plug top.Vendor shall consider minimum 6 actuators. Note : UPS power shall be provided to fire damper control panel. |
| 678 | Supply, installation, testing and commissioning of fire-retardant canvas, with GI matching flanges, with a provision of operable zip. The entire assembly shall be fabricated at factory. |
| 679 | Supply, fixing, testing and balancing of Aluminium powder coated Fresh air and exhaust arrangement with louvers, volume control damper, MS weld mesh bird screen / mounting frame -100mm louver spacing and 45 deg angle suitable for protection against splashing rain water fixed within a right aluminium frame as per specification. |
| 680 | Supply, installation testing & balancing of Higher grade Aluminium Extruded powder coated grilles with necessary flanges for Supply & Return air. As per specification |
| 681 | Supply, installation testing & balancing of Higher grade Aluminium Extruded powder coated grilles with necessary flanges for Exhaust air. As per specification |
| 682 | Supply, installation testing & balancing of Higher grade Aluminium Extruded powder coated Door Transfer Grille with necessary flanges for Fresh air. As per specification |
| 683 | Supply, installation testing & balancing of collar damper shall be constructed out of extruded aluminium alloy with multiple blade of oppose blade type. The damper to be powder coated with mat finish black colour. The damper shall be used for the Supply air diffuser & grilles as per the drawings & specifications. |
| 684 | Design, Manufacture, Supply, Installation, Testing, and balancing of aluminium powder coated ex.disc valve dia 150mm |
| 685 | Providing the third party agency for testing and balancing of HVAC system completely as per NEBB guidelines. The agency\"s technical credentialsshall be submitted to the Client / Consultant and work can be commenced after getting approval from the Client / Consultant. |
| 686 | Supply, installation testing & commissioning of Higher grade Extruded Aluminium powder coated Supply Air Diffusers shall be of removable core type(without collar damper) With Outer size: 595x595mm.& 375 x 375mm neck size |
| 687 | Supply, installation testing & commissioning of Higher grade Extruded Aluminium powder coated Return Air Diffusers shall be of removable core type (without collar damper) With Outer size: 595x595mm. |
| 688 | Supply, installation and testing of round flexible duct inner core should be made of triple lamination of Aluminium Foil, Polyester & Metalized polyester film permanently bonded to a coated spring steel wire helix. Fiberglass insulation shall be of 25mm thick with minimum density of 16 kg/m³. The outer insulation jacket vapor barrier shall be made of fiber glass reinforced metalized polyester film laminated with aluminium foil as per the technical specifications. The rate shall be inclusive of hose clamps, supports,bolt,nut etc. AS per specification.(1.2 Mtr) |
| 689 | 250mm Dia |
| 690 | 200mm Dia |
| 691 | Supply, installation testing & commissioning of Butterfly damper should constructed with Not less than 0.8mm thick galvanized steel sheet, with single flap, necessary stopper, flanges, grooves150-mm length, neoprene gasket at the edge of blade to reduce leakage and with required hardware and accessories as per specification.Include locking device to hold single-blade dampers in a fixed position without vibration & engraved marking on position of damper, as per specifications. |
| 692 | 250mm Dia |
| 693 | 200mm Dia |
| 694 | ELECTRICAL WORKS FOR VRV ODU\"s: |
| 695 | The isolator unit for single module ODU comprising 4P MCB / ELCB 300 mA in a weather proof moulded IP 55 enclosure. The unit shall be suitable for single module VRV ODU. RCBO\"s rating shall be suitable for the load of ODU unit.The item shall also include 4c x 6 sqmm armoured copper conductor XLPE cableand double copper earth of required length between the isolator box and the ODU unit. (Normally upto 20 HP, ODU, its single module ODU). |
| 696 | Single module ODU |
| 697 | The isolator unit for two or more ODU modules comprising 4P MCCBas incomer,tinned bus bar link work, outgoings as 4P ELCB / 300mAper module of ODU. The unit shall be complete with internal wiring and enclosed in a weather proof moulded IP 55 enclosure. The outgoings shall be one 4P RCBO / 30 0mA for eachmodule andshall be of adequate capacity as per the load of each module of VRV ODU. The MCCB shall be sized for the load of sum of all VRV ODU modules. The item shall include 4c armoured copper conductor XLPEcable and copper wire double earth ofrequired length from isolator box to respective VRV ODU module. |
| 698 | 30 HP |
| 699 | Supply and laying of 4 Core 4 sq.mm copper armoured Cable |
| 700 | Supply and laying of 4 Core 6 sq.mm copper armoured Cable |
| 701 | Supply and laying of 4 Core 10 sq.mm copper armoured Cable |
| 702 | FIRE FIGHTING WORKS |
| 703 | Supply, installation, testing and commissioning of Diesel Engine Driven Main Fire Pump suitable for automatic operation and consisting of following and complete in all respects as required. a. End suction, top discharge centrifugal pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg. / sq. cm at highest and farthest outlet at specified flow of 2280 LPM at 70m head conforming to IS 1520.b. 68 BHP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete. Auto starting mechanism, 12 volts / 24 volts electric starting equipment like self motor, dyanamo, solenoid switches etc.c. 110 litres capacity diesel tank mounted over stand fabricated using 25mm x 25mm x 6mm size MS angle, providing with level indicator, inlet port, outlet port, drain port and diesel return line port and fuel pre-filter, after filter etc.(Make: Kirloskar / Equivalent). |
| 704 | d. Exhaust system having flexible metallic mufler, 100mm dia MS heavy pipe extended upto 1m, outside pump house duly insulated with 50mm thick glass wool with 1mm thick aluminium sheet cladding, residential silencer with necessary MS support arrangements from wall or ceiling as per site condition.e. Dash board consisting the instruments like temperature gauge, galvano type DC Ammeter, lubricant oil pressure gauge, ignition switch, emergency stop and all other protection equipment as per specification, stop seleneid for auto stop in the event of fault with audio indications, painted with post office red colour etc., as required.f. 12 V / 24 V storage battery, maintenance free tape, 180 AH rating, MS fabricated common base plate, coupling guard, foundation bolts etc., as required.g. Positioning the diesel engine driven fire pump over cement concrete foundation using suitable size anti-vibration mounting arrangement.All works carried out as per standard methods and as instructed by the manufacturer and as directed by the SIDCO Officers.(Make: Kirloskar / Equivalent) |
| 705 | Supply, erection, testing and commissioning of Fire Fighting Application Horizontal Centrifugal Type Pump Rated for 2280 LPM at 70 metres head with Electrical Motor of 60 HP of 415 volt 3 phase connection complete with base plate and accessories. (Make: Kirloskar or Equivalent). The rate inclusive of necessary vibration, bad mounting etc., as per standard method as directed by the Departmental Officers. |
| 706 | Supply, erection, testing and commissioning of 180 LPM, 70 metres Head Pressurization Pump with 10HP electrical motor of Kirloskar make with suitable base frame including necessary vibration bad mounting etc., including conveying, fixing and incidental charges, etc., complete as per standard specification and as directed by the Departmental Officers. |
| 707 | Supplying and fixing air vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. (Fabricated ) |
| 708 | Supply, erection, testing, and commissioning of cast iron body and bronze internal PN 1.6 non-rising spindle sluice valve of sizes at required places to control the flow of water including necessary MS flange of table ‘E’, gaskets, bolts & nuts including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the SIDCO Officers. Make: NORMEX / KARTAR /EQUIVALENT. |
| 709 | 200 NB |
| 710 | 150 NB |
| 711 | 65NB |
| 712 | Supply, installation, testing and commissioning of Cast Iron Butterfly isolation valve (PN:16) as per specification with necessary flanges, GI nut, bolts & washers, painting, etc. Complete as per the technical specification. |
| 713 | 150 NB -Gear operated |
| 714 | 100 NB -Lever operated |
| 715 | 50 NB.-Lever operated |
| 716 | Supply, erection, testing and commissioning of Cast iron body and Gun metal or stainless steel internal Non-return valve of following sizes to control one way flow of water to be installed pump room at delivery line and near overhead tank at terrace level near to jockey pump and motor including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc. as per IS 5312 including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the SIDCO Officers. |
| 717 | 150 NB |
| 718 | 50NB |
| 719 | Supply, Installation and Testing of 50NB ball Valve with sight glass and union. Valve shall be made of bronze & shall be single handle ball valve..Complete as per the technical specification ( For sprinkler risers) |
| 720 | Supplying,installation,testing and commissioning of Brass ball valve having Flanged/screwed with unions ends as per specification with factory finish necessary flanges, Hot Dip GI nut, bolts & washers, painting, etc. Complete as per the technical specification. |
| 721 | 50 NB |
| 722 | 25 NB |
| 723 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. |
| 724 | Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe as per IS 1239 to withstand a developing pressure of 10 kg. / sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers & joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the SIDCO Officers.Make: JINDAL / EQUIVALENT. |
| 725 | Note: a) Hangers should not be welded or fastened directly to the pipework, b) the thickness of all parts of pipe supports should not be less than 3 mm, c) pipes should be supported from non-combustible building elements.d) Pipework in corrosive areas should be of either stainless steel or suitably protected against corrosion, e) the pipe support shall be adequately designed to withstand five times the weight of water filled pipes plus 114 kg, f) hanger support shall be provided for pipe sizes upto 50mm dia and MS \"C\" Channel support shall be provided for all pipes exceeding 50mm dia, g) The distance between the pipe supports shall not be more than i) 4.5m for pipe sizes upto 65mm dia, ii) 6m for pipe sizes greater than 65mm dia upto 100mm dia iii) 6.5m for pipe sizes greater than 100mm dia, miscellaneousconsumables and Painting the above ground pipes works with one coat of metal primer and two coats of fire red enamel paint of shade No. 536 of IS 5 : 2007. The vendor shall also consider the price for chasing / chipping walls, making bore holes in walls / floor and making them good with filler material and finished in cement mortar etc. |
| 726 | 200NB - 6.35 mm thick- Class C |
| 727 | 150 NB - 5.4 mm Thick- Class C |
| 728 | 100 NB - 5.4 mm Thick- Class C |
| 729 | 80 NB- Class C |
| 730 | 65 NB - Class C |
| 731 | 50 NB - Class C |
| 732 | 40 NB- Class C |
| 733 | 32 NB- Class C |
| 734 | 25 NB- Class C |
| 735 | Supply and fixing of Fire fighting application oblique type stainless steel Hydrant Valve of size 63mm dia with oblique type instantaneous coupling with rotating wheel to open and close the valve including MS flange of table “E”, bolts & nuts with washer as per IS 5290 at ring main around the building and wet riser inside the building including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the SIDCO Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD /EQUIVALENT. |
| 736 | Supply, and fixing in position of Fire Fighting Application Hose of 63mm dia of 15 metres length binded by copper wire with 63mm dia stainless steel male and female instantaneous fire fighting special coupling as per IS 901 as directed by the SIDCO Officers. Near every hydrant points including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the SIDCO Officers. Make: OMEX / KARTAR/ LIFE GUARD / SAFE GUARD /EQUIVALENT. |
| 737 | Supply, and fixing in position of Fire Fighting Application 63mm dia stainless steel short length Branch Pipe with hexagonal type spray nozzle of 15mm (or) 20mm jet bore. Near every hydrant points including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the SIDCO Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 738 | Supply of Fire Fighting Application MS Hose Box to keep two number of hoses and 1 No. of branch pipe with nozzle having proper glass window type double door with universe open key, painted inside white and outside Post Office Red. Near every hydrant point including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the SIDCO Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 739 | Supply, installation of Fire Fighting Application 180 degree swinging type, hose reel drum with 20mm dia braided thermoplastic hose of 30 metres long, so as to extend to necessary distance by self rolling spindle wheel including necessary 20mm dia ball valve and open and close spray nozzle, warm clip, etc., as per the standard pattern of any reputed make at every floor nearer to hydrant valve, including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary., etc., complete as per standard specification and as directed by the SIDCO Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 740 | Supply, erection, testing and commissioning of Fire Fighting 4 Way Fire Brigade Inlet with necessary gun metal 63mm dia non return spring shutter arrangements, so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the SIDCO Officers. Make: KIARTAR / OMEX /EQUIVALENT. |
| 741 | Wrapping and coating anti-corrosive treatment for the following under ground MS pipe having one coat of anticorrosive metal primer, one layer of asphalt tar tape wound over the MS Pipe as per standard methods as per standard specifications and as directed by the Departmental Officers Make : IWL- Pypkote / Rustech- Coatek |
| 742 | 150 NB |
| 743 | 100 NB |
| 744 | 80 NB |
| 745 | Supply, erection, testing and commissioning of Air Release Valve of 20mm dia, so as to release airlock in 100mm dia MS pipe at top most wet riser, including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the SIDCO Officers. Make: KARTAR /EQUIVALENT. |
| 746 | Test Array Manifold Arrangement for pumpset with pressure gauge (1 No.), pressure switch (3 No.) as per specification |
| 747 | Supply, erection, testing and commissioning of Pressure Gauge with 0 to 14 kg. range of reputed make with necessary valve, milling thread MS coupling fixed at delivery pipe line in pump house & Every floor sprinkler tap off to read the developing pressure including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the SIDCO Officers. Make: H-GURU / ISI MAKE /EQUIVALENT. |
| 748 | Supply and fixing nominal bore quartized bulb type sprinkler bulb 68 Deg C fast response pendent type including GI collar for each sprinkler bulb, mounted in MS pipe line using suitable size MS threaded coupling, thread, shellac etc., as per standard methods and including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.. |
| 749 | Supply and fixing nominal bore quartized bulb type sprinkler bulb 68 Deg C fast response upright type including GI collar for each sprinkler bulb, mounted in MS pipe line using suitable size MS threaded coupling, thread, shellac etc., as per standard methods and including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 750 | Supply, Installation, Commissioning and Testing of suitable size dummy plug for future upright sprinkler head. |
| 751 | Supply, erection, testing and commissioning of UL/FM approved Metallic stainless steel (SS 316) braided Flexible drop pipes of 1500mm length, 25mm Dia with cross bar assembly support suitable for grid ceiling, reducing fitting, special shoulder Nipple, reducing nipple, T bar bracket, bracket clip assembly as per drawing. |
| 752 | Supplying and installing of approved type Rosette Plates (Recessed Type in Two Pieces) for sprinklers below false ceiling area. The Rosette shall be fabricated by MS plate of 2mm thick and the finish shall be powder coated and colour, as directed by the Client/Architect/Consultant |
| 753 | Supplying & installing of FM approved make vane type150NB flow switches (flow sensors) suitable to be fixed directly on line of the following diameters, with 1 NO & 1 NC potential free contacts (suitable provision for IBMS system)as per specification |
| 754 | Supply and installation of FM approved 150NB alarm check valve with full valve trim. The alarm check valve shall be equipped with a removable cover assembly. The alarm valve shall be listed for vertical position. T shall be equipped with gauge connections on the system side and supply side of the valve clapper. The alarm valve trim piping shall be externally galvanised. Maximum water working pressure to 250 PSI. This shall be inclusive of hydraulic powered water motor alarm by way of integral valve alarm line trim piping.Water motor gong shall be connected to a water pressure retarding chamber to limit the propensity of unnecessary alarms.Water motor alarm shall be equipped with a rear closure plate to limit the access of foreign materials of accumulation of debris as per specification |
| 755 | Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc, complete as per standard specification and as directed by the SIDCO Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT |
| 756 | Supply and fixing of DCP (Dry Chemical Powder ) Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: Safex/ Minimax / Ceasefire |
| 757 | Supply and fixing of Carbon-di-Oxide Gas Type 4.5 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc., complete as per standard specification and as directed by the SIDCO Officers. Make: EXCELLENT /SAFETY FIRST / EQUIVALENT |
| 758 | Supply and kept in position of Trolley Mounted Type 22.5 kg. Carbon-di-Oxide Fire Extinguisher as per IS15683, complete with control valve, gun metal cap, pressure gauge, operation sticker, discharge hose, mounting trolley with moving wheel, safety clip, etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standardspecification and as directed by the Departmental Officers. Make: Safex/ Minimax / Ceasefire |
| 759 | Supply and fixing of Aqueous film forming foam 9lts. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers. Make: Safex/ Minimax / Ceasefire |
| 760 | Supply and kept in position of 9 litres capacity Fire Buckets of 4 Nos. with Bucket Stand as per standard specifications and as directed by the SIDCO Officers |
| 761 | Supplying, installation, testing and commissioning of Fire Fighting Electrical Control Panel of cubical construction, floor mounted type fabricated using CRCA sheet, compartmentalised with hinged lockable door dustand vermin proof, cable alley, inter connection having switch gears and accessories mounting and internal wiring, earth terminals, numberings, necessary metering protections and indications complete in all respect suitable for operation on 415volt, 3 phase, 50 Hz AC supply with enclosure protection class IP 54 and mounted with the followings. A. Common Panel in Fire Pump House(i). Incomera. 1 No. 600A TP & N SDFU with HRC fusesb. 1 set of 600A, 4 bar aluminium bus bar, 415 V, 50 HZ AC supplyc. 1 No. (0-500A) digital ammeter with selector switch & CTsd. 1 No. (0-500V) digital voltmeter with selector switch and control fusese. 3 Nos. phase indication lamp LED type with toggle switches with control fuses |
| 762 | (ii). Outgoinga. Main Fire Pump400 A TPN SDFU with HRC fuses with sutable HP fully automatic starter / delta starter with over load protection, digital ammeter with built-in selector switch and suitable CTs, current sensing type single phasing preventer complete with all accessories and internal wiring required for automatic operation, selector switch for auto / manual / OFF operationb. Jockey Pump125 A TPN SDFU with HRC fuses with suitable HP fullyautomatic starter / delta starter with over load protection,current sensing type single phasing preventer complete withall accessories and internal wiring required for automaticoperation, selector switch for auto / manual operation - 1 No.c. Diesel Engine Control comprising of:1. Auto / manual selector switch and 3 attempt starting device, timers and relays as required, push buttons, start /stop in manual mode.2. Indication lamp for high / low lubricant oil pressure, high water temperature and engine ON indication.3. Battery charger suitable for 12V /24V DC with boost and tickle selector switch, 0-15V / 0-30V DC volt meter, 0-20A DC ammeter. |
| 763 | 4. All standard relays and accessories for automatic operation of diesel engine.5. The above combined panel mounted over MS channel fabricated frame with cement concrete platform, all other connection works carried out as per standard methods and including conveying, fixing and incidental charges, etc.,complete as per standard specification and as directed by the Departmental Officers. From Main panel to Fire panel under Electrical scope. |
| 764 | NOTE:- Control & interlock arrangement in between Jockey Pump, Main pumps, & Diesel engine pump shall be enclosed in the panel. The panel shall also be provided with an industrial hooter for alarm and necessary suitable relays shall be provided and NO + NC contacts shall be provided for IBMS communications |
| 765 | Supply and laying of 3.5 Core 300 Sq.mm PVC/XLPE Aluminium Armoured Cable - Electrical panel to main panel |
| 766 | Supply and Laying of 3.5Core 70 Sq.mm PVC/XLPE Aluminium armoured cable - Fire pumps panel to Main pumps |
| 767 | 12 Core 2.5 Sq.mm PVC Copper Armoured Cable - Diesel Engine Auto start panel to diesel engine |
| 768 | 4 Core 16 Sq.mm PVC Copper Armoured Cable - Fire pumps panel to jockey pumps |
| 769 | 2 Core 1.5 Sq.mm PVC Copper Armoured Cable - Pressure switch cable |
| 770 | Design, supply and laying of 25 x 6 mm copper flat for panel earthing |
| 771 | Design, supply and laying of 8 gauge bare copper wires for Gland earthing, loop earthing in the existing surface/recessed steel conduit, pump earths and other equipment body earthing as required. (For Jockey pump earthing) |
| 772 | Design, supply and laying of 25x3 Copper Flat pump body earthing for electric driven pumps , diesel engine pumps and run along with cable tray |
| 773 | Supply and installation of 2m x 1m Rubber Mat confirming to IS (5 Nos) |
| 774 | Supply and erection of following sizes GI ladder type cable rack system made out of 14G GI sheet folded to required shape with adequate number of supports. The rate shall be inclusive of suitable hanging support |
| 775 | 150mm x 50mm x 2.0mm- Fire pump room jockey pumps |
| 776 | 300mm x 50mm x 2.0mm - Fire pump room Main pumps & Diesel pump |
| 777 | SIGNAGES |
| 778 | Providing and installing in position the following type of sign boards made out of 3mm thick \"Opaque\" PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board, complete with mirror fasteners. Make : Prolite / Ravel |
| 779 | Signage with printed\"IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE\" of 1.5cm height letters in red with white back ground.The size of the board shall be 25cm x 30 cm and shall be fixed at the height of 2 mts. from finished floor near Manual call points. Make : Prolite / Ravel |
| 780 | Floor indentification signage ( ie, GROUND FLOOR …etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting colour from back ground.Size shall be 15cm x 60cm.Make : Prolite / Ravel |
| 781 | Providing and fixing in position the signages \" FIRE ORDER\" it should contain the following matter on 3mm thick \"Opaque\" PVC foam board of computerised cut, PVC non-reflective self adhesive vinyle painted foam board of 3\" x 4\".ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATION . EVACUATE THE OCCUPANTS BY USING THE FIRE EXITS & EMERGENCY EXITS ONLY. ASSEMBLE AT VARIOUS ASSEMBLY POINTS. IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING THE NEAREST/SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER BE CALM, DO NOT GIVE ANY ROOM FOR PANIC, WALK, DO NOT RUN IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION, STAY IN YOUR PLAN AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM . Make : Prolite / Ravel |
| 782 | Providing and installing in position the following type of sign boards made out of 3mm thick \"Opaque\" PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board, complete with mirror fastenersACTION BY SECURITY/RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR FIRE DETECTORS OR BY USING PUBLIC ADDRESS SYSTEM. A) ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM. B) INFORM FIRE CONTROL THROUGH ANY ONE OF THE FOLLOWING PHONE NUMBERS:C) IN CASE OF THE CASUALTIES, CALL AMBULANCE BY DIALLING NUMBER…….. FIRE FIGHTING AGNECY-------------------------------PHONE : ----------------------- FAX : ---------------------------- |
| 783 | Fire and emergency signage Boards( Fire escape directions, First aid charts, First aid box indications, safe material handling procedures, Fire assembly area indications etc,) |
| 784 | Providing and installing of Fire Evacuation Plan with route inrectangular Acrylic sheet with ss bolt of size 600 x 450mm& 2 to 3mm thick |
| 785 | IBMS & ELV WORKS |
| 786 | ADDRESSABLE FIRE ALARM SYSTEM |
| 787 | Supply, Installation, Testing & Commissioning of UL Listed Intelligent Addressable Fire Alarm Panel with 5-Loop Card, as per below, The panel shall be equipped with 10% spare capacity after comissioning; with each loop having a maximum of 125 detectors and 125 devices in one detection loop.with battery back up for 48 Hrs during normal operation and 30 minutes alarm operation, with minimum 160 Character LCD display, necessary interface card to connect a repeater panel,shall have provision for additional loops, each loop shall be 80% loadedand all hardware & software as per specification. Shall support minimum Four access levels, 400 event historical logging, flash EPROM,4 Nos. of programmable relay controls. |
| 788 | Supply, Installation, Testing & Commissioning of Bacnet /ModbusGateway for Integration with BMS System. The BACNET /ModbusGateway shall act as an independent node communicating on the peer to peer network and shall not be dependant on the Fire Panel CPU for operation (failure of CPU shall not result in failure of BACNET/Modbus Gateway). |
| 789 | Supply, installation, testing and commissioning of Active repeater panel with necessary power supply unit complete all. |
| 790 | SMS alarm notification module with unlimited user capability, SMS Paging Facility for transmitting specified alarms to designated personnel.Required Hardware & Software. |
| 791 | Supply Installation Testing & Commissioning of Multi sensor detector (photo+heat) with base,powder coated back box and other accessories as required and Detectors shall be UL listed, - (TRUE CEILING/ABOVE FALSE CEILING & FALSE FLOOR) |
| 792 | Supply Installation Testing & Commissioning ofMulti sensor detector (photo+heat) with base and other accessories as required and Detectors shall be UL listed, - (BELOW FALSE CEILING) |
| 793 | Supply Installation Testing & Commissioning of Analog Addressable Heat Detector with programmable for timed automatic sensitivity selection withRequired Module for Panel Connectivity, Standard base, powder coated backbox and other accessories as required and Detectors shall be UL Listed. |
| 794 | Supply Installation Testing & Commissioning of Response indicator with powder coated back box and other accessories as requiredfor all detectors located above false ceiling / False flooring with all mounting accessories . |
| 795 | Supply, Installation, Testing & Commissioning of Analogue Addressable Fault isolator module capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected. (FIM\"s are used for every 20 detectors/devices) |
| 796 | Supply, installation, fixing, testing and commissioning ofAnalogue Addressable Monitor module withback box(1.6mm thick RED colour)operating at 24V DC, 2A, rated at 230V, provided with DPDT contact. - To monitor the flow switches, Tenant panel integration,Third Party System Integration etc |
| 797 | Supply, installation, fixing, testing and commissioning ofAnalogue Addressable Control module withback box (1.6mm thick RED colour) operating at 24V DC, 2A, rated at 230V, provided with DPDT contact,with required fixing accessories - For AHU tripping, Fans tripping, Access control tripping, PA system, Third party system integration etc. |
| 798 | Supply, installation, fixing, testing and commissioning of Addressable Electronic Hooter cum Strobe ceiling mounted / Wall Mount as per site conditions. The hooters shall be made of ABS plastic, and have a DB level of 65dbA and a multi tone facility.shall be fitted in a junction box. |
| 799 | Supply, installation, fixing, testing and commissioning of Hooter Module withJunction box and other accessories as required - To activate the hooters at fire condition |
| 800 | Supply, Installation, Testing & Commissioning of Addressable Manual call point having an integrally mounted addressable module that monitors and reports contact status. (PULL TYPE) withback box(1.6mm thick RED colour) along with required fixing accessories. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. |
| 801 | Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers. |
| 802 | Supply and fixing of approved make FRLSPVC conduits on ceiling / wall / floor etc. complete with accessories like, Junction boxes, Collars, Bends, clamps, saddles etc. (for MCP) |
| 803 | 25 mm dia. |
| 804 | SITC of PSU for hooters (inclusive of Battery ckt & battery) |
| 805 | PUBLIC ADDRESS SYSTEM |
| 806 | Supply, installation, commissioning of6W RMS False Ceiling Mount Speakers with inbuilt 100V Line Matching Transformer, wide opening angle, optimized for music & speech applications with mounting clamps as per specifications.Speakers shall be IEC and BS Compliant |
| 807 | Supply, installation, commissioning of6W RMS True Ceiling Mount Speakers with inbuilt 100V Line Matching Transformer, wide opening angle, optimized for music & speech applications with powder coated back box, supports as per specifications Speakers shall have the tappings at 1.5/3/6 watts.Speakers shall be IEC and BS Compliant |
| 808 | Supply, installation, commissioning of6 W Wall Mounted box Speakers with line matching transformers as specifiedas per specifications |
| 809 | Supply, installation, commissioning ofoutdoor 15 W Horn Speakers with line matching transformers as specifiedas per specifications |
| 810 | VOICE ALARM SYSTEM CONTROLLER:Supply, installation, commissioning of Microprocessor based System Controller with builtin 240W Amplifier, EN-54 for connecting min 6 zones, with in built 6 zone router cum control withcomplete rack mounting accessories, with 6 Zone Call Station and emergency microphone to make announcement for all thefloors with built in Stem Type Microphone on call station, integration facility with Fire Alarm System, fire trigger alarm module, message manager, Speech Processor with relays for activating pre-recorded fire alarm messages with the required interface card to connect to the additional call zone stations and required interface units to connect amplifier and routers.it will vary as per client requirement. |
| 811 | Supply, installation, testing and commissioning of 6 zone PA console with built-in Evacuation message, Microphone, with Zone expansion features, Six zone selection keys, all-call key and momentary PTT-key for call. Including power adaptors and all accessories . |
| 812 | Supplying, installing, testing and commissioning of Power Amplifier of 240 W RMS out put in rack, including necessary control wires, jocks etc. complete. |
| 813 | Supplying, installing, testing and commissioning of Power Amplifier of 480 W RMS out put in rack, including necessary control wires, jocks etc. complete. |
| 814 | Supply and laying of 2 core 1.5 sq.mm.Armoured Speaker Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers. |
| 815 | Rack MountedDVD Player/Mixer Amplifier as per specifications |
| 816 | Supply, Installation, Testing and Commissioning ofMin 36U/42U size rack as per following specification,Floor/ Wall Mounting rack with Front Glass door & Rear Plain Door with handle lock, 1 Shelf 400mm and mounting hardware packet of 20, Cable Manager, PDU 6sockets (1),Side panel Number of racks shall be as per the design requirement. vendor to consider required number of racks as per their requirement |
| 817 | IP CCTV SYSTEM |
| 818 | Supply, Installation, Testing and Commissioning of Indoor Dome Camera, Wide AngleIP dome, POE ,1/3\" CMOS, Min. 5 MP Resolution, Dual H.264 / H.265 Streaming, 25 fps, fixed lens 2.6/2.8/3/3.6mm, 0.5 lux for colour, Tamper detection, 3D Noise reduction, Auto Gain / Auto White Balance. PoEWith LATEST ONVIF ComplianceIEEE802.1X Security Protocol is must in all models IP cameras. Camera Shall also have Listing of (UL60960-1,IEC 600068-2-1,EN 55022 Class B , EN 61000-6-1, EN 61000-6-2 ) . |
| 819 | Supply, Installation, Testing and Commissioning of Outdoor IP Bullet Type Camera ( Periphery walls / Building external walls)IP Bullet Camera, POE, Outdoor Weatherproof, Min 5MP , 1/3 CMOS, IR Cut lens , IR for 25 meters, POE ,Vandal / Tamper proof, Optical WDR > 100 Db ,Auto Gain / Auto White Balance. IP 66 & Vandal proof enclosure , 3D Noise reduction, PoE & standard 12VDC/24VAC power input . IEEE802.1X Security Protocol is must in all models IP cameras.Camera Shall also have Listing of (UL60960-1,IEC 600068-2-1,EN 55022 Class B , EN 61000-6-1, EN 61000-6-2 ) . |
| 820 | Supply, Installation, Testing and Commissioning of Outdoor Application Low Light IP Hi speed Dome type PTZ camera with 2 MP Resolution, mim 32X optical zoom, Low Light ,Day/Night, Wide dynamic range > 100 dB, Dual H.264 streaming, 0.05 lux, vandal resistant, 360° continuous pan, -0° to +90° tilt, 256 preset, IP66 rated with built in heater and blower, Mounted on Wall/Pole as per site requirement (including required accessories), UL listed as per detailed specifications. IEEE802.1X Security Protocol is must in all models IP cameras.Camera Shall also have Listing of (UL60960-1,IEC 600068-2-1,EN 55022 Class B , EN 61000-6-1, EN 61000-6-2 ). |
| 821 | Joy Stick to Control PTZ Cameras |
| 822 | NVR / Server |
| 823 | Supply, Installation, Testing and Commissioning of 32 channel Network Video recorder with embedded software Up to 8 Mega pixel (3840 x 2160) recording resolution, Simultaneous HDMI, VGA and CVBS output, HDMI and VGA output up to 1920 x 1080P resolution, Gigabit network interfaces, eSATA interface for recording or archiving (3.5\" SATA I/II/III HDD*8),include Required hardware storage of 30 Days of 24 x 7 Continuous recording at 4MP 25FPS,Wireless Mouse. It shall have required graphics cards to display the cameras cameras in multiple screens, bandwidth as required (Min. 360 Mbps) or as required more to connect the 32 cameras.Including HDMI cable for monitor and all other accessories required for proper funtioning of the system.This NVR is to be accommodated in rack. |
| 824 | 43\" LED monitor with HDMI capable of 24 x 7 operation, including software, hardware,mounting bracket and fitting and accessories to stream live video to Monitor with 16 / 32 camera display per screen. |
| 825 | REMOTE VIEWING STATION (RVS) |
| 826 | Video Monitoring Station - Shall have the following configurations and features1) Processor - Intel® Core i7® Processor 2) Memory: 16 GB DDR4 ECC RAM or better. 3) OS - Windows 10 Professional; 4) Networking - 2x 1GbE RJ45 Ports5) HDD - 1 TB SATA6) Graphics Card-4 GB or more7) Supporting Two MonitorsIf vendor Server requirement is more than what is specified here, then required server configuration to be considered for Costing |
| 827 | Supply,Installation,Testing and commissioning of 32\" Monitor with HDMI Cables - Control Room with necessary mounting bracket and fitting accessories |
| 828 | 5 Meter MS Circular Pole (FROM GROUND LEVEL) - Min. 80mm dia or More as required, 2 coats of reoxide primer and 3 coats of external colour as per Architects recommendation, complete with mouting accessories as required for the pole as well as the cameras, suitable to mount the outdoor cameras to the directions of the consultant.Pole to have adjustable options to mount at different heights - 3,4 & 5 Meters. Foundation including excavation and refilling etc as required with junction box for looping of power cable. Pole type & color to be matched with Lighting pole or as required at site. |
| 829 | 2 Meter MS Circular Pole (FROM GROUND LEVEL) - Min. 80mm dia or More as required, 2 coats of reoxide primer and 3 coats of external colour as per Architects recommendation, complete with mouting accessories as required for the pole as well as the cameras, suitable to mount the outdoor cameras to the directions of the consultant.Pole to have adjustable options to mount at different heights - .5, 1, 1.5 & 2 Meters. Foundation including excavation and refilling etc as required with junction box for looping of power cable. Pole type & color to be matched with Lighting pole or as required at site. |
| 830 | Access Control System |
| 831 | SITC of Client PC for Access Management :Supply, installation, testing and commissioning of AccessServer shall comprise of the following minimum hardware:Xeon Octa Core IntelSeries Processor at mim 3 GHz 20M Cache,4GB or more of RAM, 1 Tb hard drive,DVD player- Read and write with video card and video recording application with 15 min UPS Redundant power supply unit ,Standard video display adapter Microsoft® Windowslatest 64 bit OS with AntiVirus,MS Windows Server Software and operating license; and required MS SQL Server License etc.The workstation shall be supplied with 21\" LED Monitor..If vendor PC requirement is more than what is specified here, then required PC configuration to be considered for costing. |
| 832 | Access Control Software: Supply, installation, testing and commissioning of Client Version Application Software for Access Control and attendance software for office area:- (Location :IBMS Room). Shall be Capable of Generating Multiple Reports in Excel format , such as Department wise / Door Wise/ Card Wise / Day wise / Weekly, monthly reports etc. |
| 833 | Supply, installation, testing and commissioning of IP Based Door Access controller -Capable of connecting single door / Single lane of barriers with IN and OUT readers.Supply, installation, testing and commissioning ofTwo Reader Control panel housed in MS Powder Coated Cabinet with Tamper Switch, complete with On-board IP / LAN port, and Built-in Web Server for Remote Log in to every controller.Also the Controller should have spare potential free contact to trip any third part system if required. - one controller shall have attendance software for admin office staffs.The controller shall have necessary inputs and outputs to connect the Door Electromagnetic locks, Buzzer, Fire trip and Magnetic contacts.The enclosure shall also house the necessary Power supply to the respective Electromagnetic locks. |
| 834 | Supply, installation, testing and commissioning of Readers - Smart Access card readers capable of reading cards of multiple technologies (Iclass / Proximity / Mifare). The readers shall be installed on the wall/Metal Surface/Metal Frame/Wooden Frame/Barriers. Necessary accessories to be considered. |
| 835 | Supply, installation, testing and commissioning of Access cards - Smart access card without Logo & Stickering as per requirement. |
| 836 | Supply, installation, testing and commissioning of Magnetic Contact as per specification and with all accessories complete as required |
| 837 | Supply, installation, testing and commissioning of Push Button/Switch as per specification and with all accessories complete as required |
| 838 | Supply, installation, testing and commissioning ofElectromagnetic locks -Single leaf- 600lbs with necessary Z/L brackets and mounting accessories |
| 839 | Supply, installation, testing and commissioning ofElectromagnetic locks - Double leaf- 1200lbs with necessary Z/L brackets and mounting accessories |
| 840 | Supply, installation, testing and commissioning of Emergency release switch |
| 841 | Supply and Laying of FRLS AB Copper Armoured Cable,PVC insulated, shielded PVC Sheathed layed with fittings & G.I Supports at 0.3mtr . |
| 842 | 8C x 0.75 Sq.mm |
| 843 | 4C x 0.75 Sq.mm |
| 844 | 2C x 1.0 Sq.mm |
| 845 | 6C x 1.0 sqmm |
| 846 | 3C x 2.5 sqmm unarmoured copper conductor cable for Power Supply |
| 847 | Supply and Laying of 100mm dia, HDPE with all necessary accessories. |
| 848 | Supply and Laying of 25mm dia, Heavy Gauge FRLS PVC Conduit with all necessary accessories. |
| 849 | Supply and Laying of 19mm dia, Heavy Gauge FRLS PVC Conduit with all necessary accessories. |
| 850 | Supply and fixing of GI Raceway trays with Cover - 100mmx50mmx1.6mm thick with all necessary accessories.including excavation,Floor Cuttingand refilling etc as required with junction box. |
| 851 | SITC of Power Supply Units for EM Locks & Controllers |
| 852 | Boom Barriers & Flap Barriers |
| 853 | Supply, Installation, Testing and Commissioning of 4 Set Speedflap barrier(3 Normal lane + 1 Wider lane)in SS Finish, with SS long housing, Servo position Drive with tooth holding break technology, 1800 mm Glass , sensor should be hidden not visible and shall be in specific pattern , detection shall be in algorithm based and with all mounting accessories. Capable of Free Egress in case of Fire Alarm / Emergency Event and Automatic Reset after resuming of Normal signal or Power. Mean Cycle Between Failure shall be minimum 12 Million Shall have Access reader on both sides for Bi-directional Access. |
| 854 | Articulated Boom Barrier - 4.5 mtr long Electromechanical type maintenance free Boom Barrier ,Boom made of 2mm zinc coated sheet Steel Powder coated & base of SS with reflective tape strips, with opening time less than 3 sec`s,complete with fixed support post,IP 65 Protection.It shall also include Control Panel and remotely placed manual override switch. Complete with 2 pairs ofPhotocell safe beam with Mounting Frames & SS Stand posts as required to complete the installation.all required Pushbuttons for Manual operation etc & Sensors. |
| 855 | Building Management System |
| 856 | BMS Client/ Work StationBMS Client/work workstationShall have the following configurations and features1) Processor - Intel® Core i7® Processor 2) Memory: 16 GB DDR4 ECC RAM or better. 3) OS - Windows 10 Professional; 4) Networking - 2x 1GbE RJ45 Ports5) HDD - 1 TB SATA6) Graphics Card-4 GB or more7) Supporting Two MonitorsIf vendor PC requirement is more than what is specified here, then required PC configuration to be considered for costing. |
| 857 | 32\" colour ,Flat Screen type Professional HD monitor for above client workstation |
| 858 | A 4 size Color Laser jet Printer suitable for the application, with driver software. |
| 859 | Softwares for BMS System |
| 860 | BMS software as specified with for realtime Processing of all Data being mapped in to the system by the DDCs and Protocol Integrators as mapped in the IO Summary. Shallbe Complete with Web Browser/ App Module for Remote Login, to be able to transmit user defined data in Graphical Format. Please include license as per the requirements with 20% spare. Include Eenrgy Billing software for the Tenant Billing with required customisation as per the client requirement. |
| 861 | Supply,Installation,Testing & commissioning of Serial interface Modules with Enclosure (as a part of IO Module train) for High Level integration with following 3rd Party Equipment\"s as mentioned in the data point summary. |
| 862 | The system will warrant an Exclusive, Dedicated Serial Interface card for every single individual 3rd party system (No other 3rd Party Integration shall be clubbed with any one integration ) The Interface card shall be Capable to Integrate Open protocol systems on BACnet /Modbus/LONWORKS/M-Bus/J-Bus Protocol Made available on serial RS 485 / 232 interface.Such Interface cards shall be part of the IO Train and shall Be Installed the same enclosureswhere the Other IO Hardwired Modules are installed |
| 863 | VRF integration- Integration from Master Controller. Qty as per HVAC.-1 |
| 864 | AHU VFD integration-3 |
| 865 | Energy meter integration -50 |
| 866 | UPS integration -2 |
| 867 | DG integration-2 |
| 868 | WTP integration-1 |
| 869 | STP integration-1 |
| 870 | RO Plant integration-1 |
| 871 | Fire Alarm Panel-1 |
| 872 | SITC of DDC Controller with Enclosures ( Complete with DDC controllers, IO Modules, Serial Integrator Module) as per Data point summary |
| 873 | DDC Panel for Toilet Exhaust & Liftwell Pressurazation fans |
| 874 | DDC Panel for Electrical Panel Monitoring |
| 875 | DDC Panel for Fire pumps |
| 876 | DDC Panel for Water Tanks |
| 877 | DDC Panel for PHE Pumps |
| 878 | DDC Panel for Substation |
| 879 | DDC Panel for AHU |
| 880 | Field Devices |
| 881 | Outdoor Air Temperature & RH sensor |
| 882 | Outdoor Air CO2 Sensor |
| 883 | Duct Static Pressure sensor |
| 884 | Water Level Switch (Low/Medium/High),Exact height to be confirmed before ordering. |
| 885 | Air Differential Pressure Switch for Run / Filter Status |
| 886 | Duct type Temperature & Humidity Sensor |
| 887 | Flame Proof Level Sensor For Diesel tank (Low/Medium/High),Exact height to be confirmed before ordering. |
| 888 | Cabling and Containment |
| 889 | Cabling for instrument, controls, valves to DDCs and communication cabling from DDC to central equipment complete with earthing, supports etc complete. Laid on Surface / On Cable Trays. All Cables shall be ATC,PVC Insultated,Armoured , Tinned Copper, Twisted Shield cable ferruled and tagged, and shall use lugs for termination at both ends. |
| 890 | 2 Core x 1 sq mmScreened with drain wire, Cable for control cabling |
| 891 | 2 Core x 1.5 sq mmScreened with drain wire, Cable for Integration |
| 892 | 4 Core x 1 sq mm Screened with drain wire, Cable for control cabling |
| 893 | 3 Core x 1.5 sq mm unshielded, tinned copper , Twisted cable for power supply |
| 894 | Communication cable: FRLS Communication Cable Cat 6e as per IEEE Standards / Communication Cable 2 Twisted pair x 1.0 mm2 Multistranded Screened Communication cable and 0.5 mm2 Drain wire as per requirment by System. |
| 895 | Perforated GI cable tray with Cover : complete with supports, all fittings and mounting accessories,etc complete to installation requirements.- DDC Panel cable dressing |
| 896 | 100 mm x 50 mm x 2mm |
| 897 | 200 mm x 50 mm x 2mm |
| 898 | Sub Total (e) |
| 899 | NETWORKING- DATA & VOICE |
| 900 | PASSIVE DATA |
| 901 | Supply, Laying, testing and commissioning of Unshielded Twisted pair CAT6A UTP Cable - Un Armoured (As per EIA /TIA Standards) 23 AWG Cable- Indoor through partly Tray / PVC Conduits- Only UTP Cable to be considered. Include Fluke Testing & Terminations. |
| 902 | Supply installation, testing and commissioning of 1U, 24 Port Fully loaded Jack / patch panel - Cat6A Cable Termination for Data, Voice & ELV. |
| 903 | Supply, installation, testing and commissioning of Cat6A RJ45 I/O Information Outlet with a separator to eliminate cross talk. Color to be confirmed with client before ordering - For IP Data &IP Voice, IP TV outlets. Include Fluke Testing & Terminations. Also inclusive of supply and Fixing of 1Set of 4 Module cover plate with frame only of White Colour shall only be considered under this item, but including with suitable size back box . Meant for Work stations. Suitable forData & Voice information outlets like RJ 11 , RJ 45 & TV Socket Outlets. Since the mentioned items will be mounted on the table or wall based on site conditions, if mounted on the table, the necessary provisions shall be made by the furniture vendor. i.e. set up will be mounted on the on the table top itself . |
| 904 | Supply, Installation, Testing & Commissioning of Cat6a patch cord (With Moulded boots) - 1.5 Mtr Length. |
| 905 | Supply, Laying, testing and commissioning of 6 Core OM4 Multi Mode optical fiber cable (Corrugated Steel Tape Outdoor Armoured, Loose tube, Gel Filled, 9/125 Micron OS2). Include Fiber Splicing & Fluke Testing. |
| 906 | Supply, Laying, testing and commissioning of 12-fibre 1-U rack mount optical fibre panel, loaded with 6 Duplex LC-MM adapters, 12 MM OM4 pigtail, 1m each,and 12-core Fusion Splice Tray: Consisting of panel. Include Fiber Splicing & Fluke Testing. |
| 907 | Supply, Laying, testing and commissioning of OS2 Multi Mode Optic Fiber Patchcord Simplex -2 / 3 mtr long or as required( SCAPC-SCAPC) Rack End to connect to Switches.TeraSPEED® SC/APC to SC/APC or as required, Fiber Patch Cord, 1.6 mm Simplex, LSZH, 2 mtr. Or As required as per site conditions.Cable Type to be confirmed based on the active components selection. |
| 908 | 6 Port Fully loaded LIU with all required accessories for complete functioning such as adapter plates, pigtails, adapter sleeves etc., for fibre cable connectivity at the network switch end |
| 909 | NETWORK RACKS |
| 910 | Supply, installation, Testing and Commissioning of 12U/15U IT Industry standard Rack with Black Powder Coated, Secured Lock with Key, with standard trays, Fans, Castors, Front Glazed Door & Rear MS Door. |
| 911 | Supply, installation, Testing and Commissioning of 42U (800mm x 1000 mm) ClosedRack with Perforated lockable front and back doors( 2 Nos), Fan at the top of the rack (Min. 90 CFM), AC Main Channels( Min 10 Points of 5.15A Sockets) vertical x 2, AC Distribtion Box, PDUs, Side Panels, Vertical Cable management high density rack at right and left, Horizontal Cable Manager, Cantilever Tray, Earthing Kit, Front Mounting Cable guides x 4, Front Cover at both sides, Adjustable Levellers with castor wheels, Mounting Hardware & all Acessories as required - Server Room |
| 912 | FRLS PVC CONDUITS |
| 913 | Supply and laying of heavy gauge rigid PVC conduit of 2mm thick with all conduit accessories PVC junction/pull boxes, G.I fish wire, fixing accessories etc, as required complete for earth cables mechanical protection ( Including wall chipping and covering with cement morter by providing chicken wire mesh wherever necessary and also GI Fish Wire. )Note : For Earthing cables |
| 914 | 32 mm dia Conduit |
| 915 | 25 mm dia Conduit |
| 916 | Supply, Fixing of Perforated GI cable tray with Cover : complete with supports, all fittings and mounting accessories,etc complete to installation requirements.- |
| 917 | 300 mm x 50 mm x 2 mm |
| 918 | PIPES |
| 919 | Supplying, laying, installation, testing and commissioning of Double Wall Corrugated (DWC) pipes complete with all fittings and accessories; Pipes shall be installed in Group Saddles; group saddles is in vendor scope and the same shall be supplied by the vendor - 50mm DWC Pipe for cables with couplers excavation, back filling, etc as per standard, complete with fittings and clamps including cutting and making good etc. |
| 920 | ACTIVE DATA |
| 921 | Layer2 Switches & Components |
| 922 | Supply, Installation, testing and Commissioning of Layer 2 Managed Switch- 24 ports of 10/100/1000 MBPS or more with 4 SFP Ports & Stacking Kit. Include all Accessoriesas required as per site specific requirement for complete functioning. All Accessories shall be of same Make as the OEM. |
| 923 | Supply, Installation, testing and Commissioning of Layer 2 Managed POE Switch- 24 ports of 10/100/1000 MBPS or more with 4 SFP Ports & Stacking Kit. Include all Accessoriesas required as per site specific requirement for complete functioning. All Accessories shall be of same Make as the OEM. |
| 924 | Supply, Installation, testing and Commissioning of SFP Modules - 1G |
| 925 | Layer3 Switches & Components |
| 926 | Supply, Installation, testing and Commissioning of Layer 3 Managed Switch- 24 ports of 10/100/1000 MBPS or more with 4 SFP Ports . Include all Accessoriesas required as per site specific requirement for complete functioning. All Accessories shall be of same Make as the OEM. |
| 927 | Supply, Installation, testing and Commissioning of SFP Modules - 1G |
| 928 | Wireless Access Points |
| 929 | Supply, Installation, testing and Commissioning ofAccess Point and All required Accessories,etc Support Wifi 6 Technology,Transfer speed Min 1400 Mbps. POE powered and Enhanced Security |
| 930 | ACTIVE VOICE |
| 931 | Supply ,installation ,Testing and commissioning of IPPBX System with100 IP Ports |
| 932 | IP / SIP Licensesfor IP Phones - 100 Users |
| 933 | IP Telephones(Receiption-2, Tidel office-2,IBMS Room-1, Multipurpose-1 and Security Room-2) |
| 934 | OFC to UTP Media Convertor - Mediaconverter to convert 100/1000 MBPS BASE-TX ethernet twisted-pair signals to100/1000 MBPS BASE FX fast ethernetfibersignals,supportfullduplexethernetmode,withtwo connectors one for transmission and other for reception, with RJ-45 port, two LED\"s for detecting the fiber link and ethernet link,fiberdistance for multi mode upto 2 Km and single mode upto 15 Km, power input: 9V 1A Adapter and complete withother accessories. Unitshallbe mounted inIP-66 housing. |
| 935 | IP 66 Weather Proof Enclosure at Poles / outside cameras with required Socket /Switches (As reqd) to accommodate Media converters, power supply & Fiber terminations etc. |
| 936 | 3 Core x 1.5 sq mm unshielded, tinned copper , Twisted cable for power supply |
| 937 | TALKBACK SYSTEM |
| 938 | Supply ,installation ,Testing and commissioning of Talk Back call station 20 Zone of desk mountable with Zone selection switch and output impedance of 220Ohm, Frequency response 150Hz-10KHz ,Sensitivity 0.7mV at 85 dB SPL with required accessories |
| 939 | Supply ,installation ,Testing and commissioning of Single Loop ,Zone distribution Unit 20 Zone of Rack Mountable with frequency response of 150Hz-10KHz , Max input sound level 100V SPL ,Current Consumption <02 Amp ,Power Supply 230V ,50Hz ,AC supply with required accessories |
| 940 | Supply ,installation, Testing and commissioning of Addressable Talkback speaker with inbuilt Hooter , 6W Speaker ,Flush/Wall Mountable with required fixing accessories |
| 941 | Supply ,installation, Testing and commissioning of Conventional Booster Amplifier 240W |
| 942 | Supply and installation of PA Rack 9U Wall mountable with all accessories |
| 943 | Supply and laying of 6 core 1 Sqmm shielded flexible cable |
| 944 | Supply and laying of 25mm dia PVC Conduit |
| 945 | LIFTS |
| 946 | Design, Engineering, Supply, Fabrication, Erection, Testing, commissioning and handing over of 16 persons capacity passenger lift as per the following specifications.(Gearless lift without machine room) |
| 947 | Design, Engineering, Supply, Fabrication, Erection, Testing, commissioning and handing over of Goods Lift (2000 Kgs) as per the following specifications (Machine room less) |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy