| 1 | Maitenance and repair of Electrical Installation by providing manpower as stipulated in terms and condition to attend day to day complain and to keep both internal and external EI installation with periodical maintenance including repairing and replacement of major spares (to be supplied departmentally) and up keep of all sorts of electrical appliances(except those personnaly installed by the dwellers in quarters) and maintenance/ repair/ operation of street illumination, common srea lighting at office quarter complex, Bunglow, and operation of pump etc.generally with L.T supply time to time as & when required at Bantala Irrigation Colony under Irrigation & Water ways Department as per Direction of Engineeer In Charge.( Contractor should arrange his own tools & tackles for the job,Labour rates are inclusive of GST, Cess, ESI, EPF, Bonus, & CP & OH T&Pcharges ) |
| 2 | 1 No Electrician (Skilled)/ day, (1 No/shift x 1 shift), i.e 313 days x 1 no/day= 313 mandays. |
| 3 | 1 NoHelper for Electrician ( Semi Skilled)/ day, (1 No/shift x 1 shift), i.e 313 days x 1 no/day= 313 mandays. |
| 4 | Supply of EI Material |
| 5 | Angular Batten Holder (Anchor) |
| 6 | Anchor grip PVC insulation Tape 7.5metre Length. |
| 7 | Supplying of different types of LED lamps (9W)Make : Philips, 9.0 Watt, Base B22/ E27, 825 Lm |
| 8 | Supplying following sizes Capacitor of 250V rating:2.5 MFD Capacitor (Universal Make or equivalent) |
| 9 | 1.5 sq.mm \"FR\" stranded Copper Wire |
| 10 | 2.5 sq.mm \"FR\" stranded Copper Wire |
| 11 | 20A Combined power plug, switch and fuse unit (Make - Anchor) with box |
| 12 | 6A piano key type switch. |
| 13 | 5A,3 pinpiano flush type socket. |
| 14 | 15A,3 pinpiano flush type socket. |
| 15 | Step type electronics Fan regulator, Make- Anchor or eqivalent. |
| 16 | Ding Dong Call Bell (Anchor) |
| 17 | Supply Philips LEDtube, model no : Mas LEDtube 1200mm 18W865 T8 – 2100lm |
| 18 | SP MCB 6 A/10A/16A/25A/ 32ASP (C-curve 10 KA, make Siemens) |
| 19 | Supplying of 40 A D.P Isolator.(Make Seimens) |
| 20 | Supplying of approved make high speed ceiling fan (ISI marked) of following sizes having double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 voltsi) 900mm/ 1050mm/ 1200mm |
| 21 | Supply of Philips smart Bright Street light, 68 Watt, Type-BRP062 LED 68 CW SLCS1 PSU |
| 22 | Supply of 3 pole power contractor type ML 1.5, 25A current rating |
| 23 | Supply of 240VAC analog time switch for ON-OFF control of street light |
| 24 | ML 1.5 Spare Contact Coil |
| 25 | Maintenance Work. |
| 26 | Supply and fixing of Field StarFlood Light Luminairewith PDC housingarea lighting , (200Watt)complete with all accessories to be fixed /projected from the wall of the building or on pole incl. making holes/providing clamping arrangement & necy. connectionas required and mending good damages to wall incl. painting etc.Make : Philips, 200 watt |
| 27 | Supplying swaged and welded steel tubular pole of following specifications as per IS 2317: 1980, 9m length, 113 Kg, 410 - SP-28. |
| 28 | Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly.(a) Upto 9.0 mtr. Size 0.6x0.6x1.70 mts |
| 29 | Supply of Philips Smart Bright Street Light , 68Watt, Type- BRPO62LED CW SLC S1 PSU |
| 30 | Supplying of following XLPE Insulated Aluminium Conductor Armoured Cables of 1.1 KV Grade As per IS 7098 (Part -1) 1988 with up to date Amendments (Rate in Rs. Per Mtr.) Conductor cross section in SQ.Mm.4 Core 10Sq.mm |
| 31 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, includingfilling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed |
| 32 | Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip)Wire, making holes etc. as necy. mending good damages and painting |
| 33 | Supply and Fixing syntax made water proof looping cable box of the following size as indicate below comprising of one 250v, 6A SP MCB unit, one NL on porcelain insulator incl. One(01) 4 pole terminal connector etc incl internal connection and housing the same above the muffing by suitable pole clamp etc complete, size of box: 250 x 200x 105 mm. |
| 34 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :For 4 core,upto 10sqmm |
| 35 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket(Dowels make), tapes, anticorrosive paste & jointing materials,4core 10 sqmm cable |