| 1 | Materilal and Labour for Comprehensive maintenance / repair and servicing of two electrically operated lifts of Capacity 08 Passenger of 544 kg serve for (G + 6) floors and 13 Passenger of884 Kg serve for (G + 6) floors complete through OEM with electrical/control panels and all connected Gadgets/Devices including ARDs and replacement of all defective parts and sundry items like grease, lubricant oil, cotton waste, small pieces of cable lugs for different capacity lifts at the following location in INS Agraniall as specified and directed by Engineer- in-charge :-(a)08passenger lift of 544 kg at MAP Phase IIbuilding used for (G + 6) floors. Make of lift : ESCON Elevators(b)13passenger lift of884 Kg at MAP Phase II bldg user for (G + 6) floors Make of lift : ESCON ElevatorsNote:-The comprehensive maintenance shall be done through OEM of the lift i.e. M/s M/s Escon Elevators |
| 2 | Materilal and Labour for Comprehensive maintenance / repair and servicing of one electrically operated lifts of Capacity 08 Passenger of 544 kg serve for (G + 4) floors complete through Platinum Maintenace Agreement with M/s TK Elevators India Pvt Ltd. for 11 monthsincl range of components for reasons related to normal wear and tear as per Note No 1(i) at the following location in INS Agraniall as specified and directed by Engineer- in-charge :-(a) 08passenger lift of 544 kg at NOM P 87building used for(G+ 4) floors. Make of lift : TK ElevatorsNote for item No.2 :-1. Terms for Component replacement by OEM( Platinum Maint Agreement)(i) The comprehensive maintenance shall be done through OEM of the lift i.e. M/s TK ELEVATORS.(ii) Coverage shall be inclusive of, ropes, inverter systems, and controller parts to be inclusive of printed circuit boards. Machine replacement is excluded however repair is included. Sub components inclusive of roller bearings, solenoids, coils Line chock, brake shoe liners, Door Lock contacts,contactors, relays, push buttons, door operator VVVF drive, car door safety device limit switches, governor,hoist way door locks, indicators and other minor mechanical parts shall also be included except as excluded elsewhere. Contractor will submit copy of platinum maintenance agreement with M/s TK Elevators within 10 days after issuence of acceptance letter by Accepting officer. Work order for the work will be issuedafter verification of Platinum maintenance agreement with M/s TK Elevators. |
| 3 | General Notes for Item No. 1 & 2:- (i)The contractor shall inter into an MOU(Memorandum of understanding) with the OEM or their authorised agency for maintenance of lift.The above comprehensive AMC certificate shall be provided by the contractor in favour of AGE(I) Agrani before commencement of work,after acceptance of CA.(ii)All the parts shall be genuine and shall be from original equipment manufacturer(OEM) and shall be as approved by AGE(I).(iii)All stainless steel parts such as lift car enclousure,opening doors,jumps,cills etc shall be thoroughly cleaned to remove rust,stains etc with suitable solution.The contractor shall also clean maintain properly the machine room, machinaries and lift as directed by Engr-In-Charge. The rates quoted for respective items shall be deemed to include for the same.(iv)Any breakdowns/complaints shall be attend and rectify within 12 Hrs. If the complaint not attended and rectified within 24 Hrs, Panalty of Rs 2000/- per day will be charged.(v)The rates quoted for above items shall be included for replacement of any minor spares,consumables accessories like fan,light/cabin light,alarm,ups batteries and all other connected items becoming unserviceable during the contract period and nothing extra will be charged.(vi) Major spare parts if any found defective during the period of contract to be replaced as catered here in after and shall be measured and paid separetely under relevant items.(vii) The contractor is responsible to carried out periodical routine check up(Monthly/Quartely) through OEM(Once in a month) or as per the direction of Engr-In-Charge to ensure the serviceability and proper functioning of lifts in all respect(Each month will be considered as 01 Job) |
| 4 | General Notes for Item No. 1 & 2 (contd..):- (viii)The contractor is responsible to clean/Empty the lift pit with necessary equipments and make lift operational ( If water found filled in the pit during rainy season)the rates for the same is deemed to be included in the quoted rate.(ix) The contractor should ensure all provisions as laid down by State/Central Govt, Labour Commissions. Employees provident fund payments, Employee Insurance, minimum fair wages, working conditions.(x) Renewal of Lift Insurance and Licence to be made from the Lift licence issue authority Govt of Tamil Nadu and display certification of lift license in lift car etc are to be complied No extra payment shall be made on account of renewal of license. (xi)Well trained, service engineer/technicians deputed by OEM are to be employed at site for lift maintenance.Prior approval in this regard is to be obtained from AGE(I) Agrani.(xii)The work will be of continuous in nature without Sundays, Holidays or Strikes and the contractor must employ lift technicians for the work when necessity arises.(xiii) The service engineer/technician should ensure the serviceability of the lifts for every odd situation.The contractor should ensure full safety and security of personnel deployed. Any casualty or injury sustained by the service engineer/technician during the currency of thecontract at the defence premises shall be sole liability of the contractor.(xiv) All tools & plants or transport required for carrying out comprehensive maintenance and necessary stationary & documents (log book) records at each lift installation will be arranged by the contractor and nothing extra will be admissible on this account. |
| 5 | Supply and Fixing in replacement of OSG Pit Pulley with Bracket for 13 Passenger Lift Make: ESCON |
| 6 | Supply and fixing of GM Single outlet Fire Hydrant Valve, 63 mm female inst. Oblique type and 80 mm flanged inlet as per IS:5290 with ABS Blank Cap and GI Chain.Make AAAG / NewAge |
| 7 | Supply and fixing ofRRL Fire Hose GM of 63 mm dia. X 15 Mtr.as per IS: 636, Type-B (RED), ISI marked with, 63mm male & female coupling as per IS: 903, ISI marked banded with copper wire. Make AAAG/ NewAge |
| 8 | Supply and fixing of Short Branch Pipe GM-304, 63mm x 20mm with Nozzle as per IS: 903, ISI Marked. Make AAAG / NewAge |
| 9 | Supply and fixing Double Door Hose cabinet to accommodate one piece of hose pipe along with one pair of male and female coupling and one branch pipe. The cabinet is made of 18 swg M.S. Sheet, Glass fronted with hinged door and lock. The cabinet is painted to red color,with required nuts,bolts etc. Make SRS |
| 10 | Supply and fixing of Hose Reel drum of swinging type with 19mm dia Rubber braided hose of 30M. length with Gate valve (upstream) and Shut off nozzle.Make AAAG / NewAge |
| 11 | Supply and fixing of Fire Brigade inlet Siamese connection (4 way) Non Return Valve, along with 4 Nos. 63 mm dia instantaneous inlet arrangemnets to the main header with cap and chain etc.,[For Water TankInlet]. Brand-KARTAR/ Equivalent |
| 12 | Supply and fixing of Butterfly valve slim seal standard lever operated type confirming to IS:13039 with required type confirming to IS:13039 with required flanges, nuts, bolts etc – C.I Heavy ISI-100 mm dia.Make :LEADER /KARTAR |
| 13 | Supply and fixing of of Non return valve wafer type check valve with required flanges, nuts, bolts etc- C.I-Heavy -ISI 100 mm dia Make :LEADER /KARTAR |
| 14 | M&L formanual calling point (MCP) indoor type four wire EN54-11 Type A standard approved by LPCBall as per HoneywellHM-MCP-GLASS CALL POINT or as per sample, all as per specified and directed. |
| 15 | Supply only test keys suitable for MCP make Honeywell all as specified and directed. |
| 16 | Supply only glass element suitable for MCP make Honeywell all as specified and directed. |
| 17 | S&F in repairs rubber flange suitable for CI butterfly valve 80,100 and 150mm dia incl taking down valve and refixing after replacement of flange all as specified and directed by Engr in charge. |