| 1 | Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. |
| 2 | Supplying and filling in foundation, basement, etc with filling M.Sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 3 | Cement Concrete 1:5:10 (one cement five C.S.Sand or M.Sand and Ten aggregate) using 40mm gauge hard granite broken stone jelly for foundationincluding cost and conveyance of all materials labour formixing, laying, compacting, curing, dewatering, side shuttering, wherever necessary including curingetc.,complete complying with standard specification and as directed. |
| 4 | Random Rubble Masonry in Cement Mortar 1:5 (one Cement and five sand) using new rough stone and bond stone for foundation and basement including simultaneous flush pointing, curing etc complete. |
| 5 | Foundation and basement |
| 6 | Ground Floor Superstructure |
| 7 | Providing and laying in position, Standarised Concrete Mix M20 Grade in accordance with IS : 456-2000, using 20 mm and down graded hard brocken granite stone jelly for all RCC items of works with minimum cement content of 325 kg /m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommanded proportions as per IS : 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about ( 5 cum )7730 kg of 20 mm machine crushed stone jelly and with about( 3.30 cum )5156 kg of 10 - 12 mm machine crushed stone jelly and with about ( 4.79 cum )7670 kg of M.Sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing etc. and providing fixtures like fan clamps in RCC floor / roof slabs where ever necessary without claiming extra etc, complete complying with standard specification. |
| 8 | Foundation and Basement |
| 9 | Ground floor Superstructure |
| 10 | Providing form work for centering the soffits of all reinforcement cement concrete surfaces including strutting to the required height with M.S.Sheets of 90 x 60cm x 10 gauge stiffened with welded M.S angle of size 25x25x3mm laid over silver oak joints of size 10cm x 6.50cm spaced at about 90cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at 75cmcentre to centre complying with standard specification - |
| 11 | \"Column footing, Grade beam and Plinth beam |
| 12 | Slab, Beam, Lintel |
| 13 | Column, Sunshade and Loft |
| 14 | Curved Surfaces |
| 15 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. |
| 16 | Brick workusingCountryBricks of size 83/4\" x4 1/4\"x 2 3/4\" in Cement Mortar 1:5 (One cement and fiveM.Sand) including curing neat finishing, etc., complete complying with standard specifiction -.Foundation and Basement |
| 17 | Brick workusingCountryBricks of size 83/4\" x4 1/4\"x 2 3/4\" in Cement Mortar 1:6 (One cement and sixM.Sand) including curing neat finishing, etc., complete complying with standard specifiction.Ground floor Superstructure |
| 18 | Brick work in Cement Mortar 1:4 (one cement and four sand) using best quality Chamber Bricks 9\"x43/8\"x23/4\"for all Varivargams, moulds, sthambams,Mukapathrams, Koodu, Nasi and all Ornamental works complete all pancharams agaris,Karnakoodus etc., |
| 19 | Plastering wall with cement mortar 1:5 (one cement and five P.Sand) 12mm thick complying with standard specification |
| 20 | Special ceiling plastering and finishing the RCC exposed surface such as RCC slabs sunshade facia canopy slab staircase waist slab landing slab etc with cement mortar 1:3 (one cement and three P.Sand) 10mm thickand as directed complying with standard specification. |
| 21 | Pointing thejoints in RR masonry with Cement morter 1:3 20mm deep usingincluding cost of special tools such brush and watering, curing etc complete, as per standard specifications |
| 22 | Brick work using II class chamber burnt bricks of size 9\" x 4.3/8\" x 2 3/4\" in Cement Mortar 1:5 (one cement and five C.S.Sand (M.Sand) ) for the following including finishing and curing as directed by the departmental officers etc., complete complying with standard specifications. - G.F.Superstructure |
| 23 | Providing Vargapoochu over the core walls of Rajagopurams / Vimanams with in Cement Mortar 1:4 (one cement and four sand) complete including shaping the Mugapathrams, Mahanasi, Koodu, all Ornamental works to proper shape etc.complete |
| 24 | Weathering course concrete using best quality broken brick jelly of size 20mm uniform gange in pure slacked line (no C.S.Sand or M.Sand to be used) the proportion of brick jelly to lime being 32: 12 ½ by volume and laid over the RCC roof slab in a single layer and consolidated to the required and designed finished thickness by beating the concrete by wooden beaters of approved pattern keeping the surface constantly wet by sprinkling lime Jaggery water etc. complete complying with standard specification. |
| 25 | Finishing the top of roof with one course of approved first quality of new Machine Pressed tiles of size 200mm x 200mm x 20mm thick of approved quality laid in C.M. 1:3 (one cement and three C.S.Sand or M.Sand) 12mm thick mixed with water proofing compound conforming to Indian standard as approved by the departmental officers at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same mortar mixed with water proof compound and red oxide etc. complete complying with standard specification. |
| 26 | Supplying and fixing in position of Polished Kotta Stone of size 600mm x 600mm of 25mm thick laid over bsae layer of Cement mortatr 1:3, 20mm thick and polished with polishing materials using different grade of Carbourundum stones Italick aid brick Oxide so as to make it glossy polishing finishing etc.,with machine polishing and as directed by the departmtntal officers.The Kota Stone should be pointed with Cement mortatr 1 : 3 ( One ement and Three C.S.Sand or M.Sand ) mixed with black oxide and Top rubbed smooth etc., complete complying with standard specification. |
| 27 | Supplying and fixingmild steel grill including costconveyance of all materials and fixing in position including priming coat etc complete with standard specifications. |
| 28 | Painting two coats of newly plastered wall surface with water based exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. |
| 29 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors including cost of priming coatwith zinc chromite etc., complete complying with standard specification. |
| 30 | Cement Concrete 1:3:6 (one cement three C.S.Sand (M.Sand) and six aggregate) using 20mm gauge hard granite broken stone jelly including cost and conveyance of all materials labour formixing, laying, compacting, curing and side shutteringetc.,complete complying with standard specification and as directed. |
| 31 | Paving flooring with Cut Stone of size 0.60 x .60M and 10cm thick and top surface dressed, pointing with Cement Mortar 1:3 (one cement and three C.S.Sand (M..Sand)) including cost and conveyance of all materials etc., complete as per standard specifications. |
| 32 | Paving flooring with Cut stone of size 0.60 x .60M and 10cm thick and top surface dressed, pointing with Lime Mortar 1:2 (one lime and two C.S.Sand (M..Sand)) including cost and conveyance of all materials etc., complete as per standard specifications. |
| 33 | Painting with multicolour (Panchavarnam)good enamal paints complete for the Vinamans/Gopurams, inculding costand conveyence of all materials, lobour charges inculding Artist painter, working in heights, lifting of material, cost of brushes etc,complete-which including all extra for foldings |
| 34 | Vimanam / Gopuram upto 25 feet height |
| 35 | Vimanam / Gopuram upto 15 feet height |
| 36 | Scaffolding charges for Vimanams andgopurams with casurina posts coconut or plamtrees wherever necessaryfor main, form work and providing with non flammable coverings, providing ladder arrangements, country wood pland for working, inpection etc, complete hire charges only for erection, maintainance and removing the same on completion of the work. |
| 37 | Vimanam / Gopuram upto 25 feet height |
| 38 | Vimanam / Gopuram upto 15 feet height |
| 39 | Providing new sudhai vigrahams in the vimanams and Rajagopurams with Copper rod reinforcement of suitabledia with binding wires wherever necessary, shaping the core with broken bricks set in CM 1:3 finishing the same with CM 1:3bringing to the correct shape (Lakshana) in conformist with silpa sastra inclusive of special ornaments, weapons, peedam etc., complete and providing C.M. Nayam theervai wherever necessary. inclusive of cost and conveyance of all materials, such as cement broken bricks, and Copper rods. binding wire all labour for working in heights, curing lifting of materials etc., complete including Exterior Emulsion painting 2 coats over a primary coat.- 2\"6\" to 3\"6\" height |
| 40 | Water washing the stone surfaces restoration by proving water jet wash using appropriate methodology withlite tespal liquid ammonia to restore the originalities of the existing granite structure inclusive of hire charges of all tools and plants employed,scaffolding arrangements, conveyance charges of all materials to siteand labour for work etc.complete as per standard specifications. |
| 41 | Labour charges for pointing the Cut stone masonary work with Combination Mortor LM1:1.5 excluding cost and conveyance of cut stone but including all labour charges scaffolding etc complete with standard specifications. The lime used should be sourced fromwhich is highly iron fortified and suitable for structural and masonry works. |
| 42 | Dismantling Brick/stone masondry in cement mortor including all labour charges and tools requirred etc., and convaying to low lying area nearby to 5km lead etc.,complete |
| 43 | Finishing the top of roof with one course of approved first quality of new Machine Pressed tiles of size 200mm x 200mm x 20mm thick of approved quality laid in L.M. 1:2 (one lime and two sand) 12mm thick mixed with water proofing compound conforming to Indian standard as approved by the departmental officers at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same mortar mixed with water proof compound and red oxide etc. complete complying with standard specification. |
| 44 | Dismantling, clearing away and carefully stacking the materials useful for reuse - Cuddappah slab flooring |
| 45 | Labour charges for dressing and fixing the Cut stone three line dressed on all face set in Lime Mortar 1:2 including handling charges, cost of tools and fixing in position etc complete with standard specifications. |
| 46 | Pattiyalvari |
| 47 | Chithiravanam |
| 48 | Upapeedam padmajagathi |
| 49 | Upapeedam Kandam |
| 50 | Pillar |
| 51 | Pothiyal |
| 52 | Uthiram |
| 53 | Pavukal |
| 54 | Kodungai |
| 55 | Vyalavari |
| 56 | Side wall upto Pothiyal top |
| 57 | Supply of Cut Stones for masonry works including cost and conveyance to work site and all labour charges required for loading, unloading and stacking for measurements as directed by the departmental officers. |
| 58 | 1\" x 1\" - upto 5ft |
| 59 | 1\"6\" x 1\"6\" - upto 10ft |
| 60 | 2\" x 2\" - upto 15ft |
| 61 | Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch with painting of |
| 62 | Supply and Fixing of 20W 4 Feet LED Fitting with LED Tube with TW round blocks on wall or ceilingwith PVC unsheathed copper leads from terminals to the fitting |
| 63 | Supply and fixing of9 W LED bulb for BH point |
| 64 | supply and fixing of 30W LED street light fitting with LED (Lower end) with 25mm dia. GI pipe (class B) with1 no.25mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting |
| 65 | Supply and fixing of 1200mm (48\") AC ceiling fan complete with stepped electronic 300W regulator with 300mm down rod on the existing clamp |
| 66 | Supply and fixing of 375mm (15\") sweep (heavy duty) AC exhaust fan complete without provision of holes in the wall |
| 67 | Supply and fixing of louvers shutters arrangements for 375mm (15\") sweep light duty AC Exhaust fan |
| 68 | Supply and fixing of 3 Nos. 5A (3 pin and 2 pin) combined flush type wall socket with control switches concealed in suitable TW box covered with hylem sheet in flush with wall with earth connection (for computer plug socket) |
| 69 | Supply and fixing of 5A / 15A 3 pin combined flush type wall socket with 15A flush type switch concealed in suitable MS box in flush with wall and covered with 3mm thick hylem sheet |
| 70 | Supply and run 35mm x 45mm powder coated duct with door arrngement complete with MS angle nd bolt 7 nuts complete |
| 71 | Supply and fixing of 40 x 40 x 6mm MS angle and 2 nos 12mm threaded rod,with 4nos 12mm nuts and 4nos 12mm washers with double coated suitable painting |
| 72 | Supply and Run of 2 of 2.5 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade insuitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 14 SWG TC wire with painting of suitable colour |
| 73 | Supply and run of 2 of 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour |
| 74 | Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with doubledoor (metal) with 1 no. 40A DP MCB Isolator as incoming and 6 nos. 6A to 32A SP MCB as outgoing onsuitable angle iron frame on wall with earth connection only. Lower End |
| 75 | Supply and fixing of 4 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution boardwith double door (metal) with 1 no. 40A 4P MCB Isolator as incoming and 12 nos. 6A to 32A SP MCB asoutgoing on suitable angle iron frame on wall with earth connection only. Lower End |
| 76 | Supply and run of 1 of 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in existing concealed rigid pipein wall and ceiling for inverter line |
| 77 | Supply and run of 4 x 6 sq.mm. (84 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V on 7 / 20 GI bearer wire for service connection mains |
| 78 | Supply and run of 4 x 6 sq.mm. (84/0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in 32mm dia GI pipe (Class \"B\") suitably bent at both ends with necessary angle iron up right and end supports for mains |
| 79 | Earthing as per the ISI specification with an earth electrode of 2.10 metre Class \"B\" GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry |
| 80 | Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection |
| 81 | Supply and run of 2 of 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour |
| 82 | Supply and run of 2 of 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V on 7 / 20 GI bearer wire for service connection mains |
| 83 | Supply and run of 2 of 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in 25mm dia GI pipe (Class \"B\") suitably bent at both ends with necessary angle iron upright and end supports for mains |
| 84 | Supply and fixing of Havells JETAALBA - FLOOD LIGHT -70W LED Fitting with Necessary Wall Grouting clamps with Fixing bolts on ceilling with PVC unsheathed Copper leads from terminals to the fitting. |
| 85 | Supply and fixing of 1.5 mts 25 mm GI pipe with necessary bending and clamp with 1 no 9W LED bulb |
| 86 | Supply and fixing of 65 mm dia. (2 -1/2\") GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mmMS base plate duly welded at the bottom with concreting with construction of masonary pedestal withsuitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 30W LED street light fitting with LED (Higher end) with 1 metre 32mm dia.GI pipe (class B) Complete with suitable MS clamps for LED steet light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour . |
| 87 | Supply and laying of 2 x 10 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good |
| 88 | Supply and clarnping of 2 x 10 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps |
| 89 | Supply and fixing of brass cable gland for 2 x 10 sq.mm. PVC armoured LTUG cable with earth connection |
| 90 | Supply and fixing of Douple pole sheet steel enclosure with 1 no 30 A DP isolator on wall and necessary connection for street light control |
| 91 | Supply and fixing of Four pole sheet steel enclosure with 1 no 30 A FP isolator on wall and necessary connection for motor control |
| 92 | Supply and fixng of TNEB meter board suitable for 3 phase 63A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2\" x 1-1/2\" x 1/4\" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 63A fuse units (500V), 1 No. neutral link, copper earth flat of size 1\" x 1/4\" with inter connection of EB meter to fuse units by 16 Sq.mm PVC insulated copper wire with earth connection complete |
| 93 | Sub total |
| 94 | GST 18% |