| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: 25 meter beyond 1 m from cutting edge |
| 2 | Providing and laying in position cement concrete of specified grade including curing but 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)excluding the cost of centring and shuttering. All work upto plinth level with. |
| 3 | Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with:Cement mortar 1:6 (1 Cement : 6 coarse sand) |
| 4 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutmen\"ts, posts ans sturts, etc. upto floor five level excluding cost of centring, shuttering, fmishing and reinforcem 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded crushed stone aggregate 20mm nominal size: |
| 5 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 7 | Dry stone pitching (any thickness) excluding cost of stones. On Horizontal |
| 8 | Centering and Shuttering including strulling, popping and removal of form work: Foundation and Plinth: |
| 9 | Centering and Shuttering including strulling, popping and removal of form work: Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 10 | Centering and Shuttering including strulling, popping and removal of form work: Columns, pillars, piers, abutments, posts and struts |
| 11 | Random Rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including levelling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) and curing complete at window sills, ceiling level and the likeCement mortar 1:6 (1 Cement : 6 coarse sand) |
| 12 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded |
| 13 | Providing corrugated G. S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G. I limpet washers or with G. I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusse 0.50 mm thick with zinc coating not less than 27 5gm/m 2 |
| 14 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.50 mm thick with zinc coating not less than 275 gram/m2 |
| 15 | Providing and fixing plained eaves boarding 2nd class kail wood 250x32 mm (nominal size ) |
| 16 | Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately) :Natural colour insulating board 12 mm thick. |
| 17 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position : Budloo I Fir wood |
| 18 | Providing and fixing wooden moulded corner beading of size 50 x 50 mm (base and height) of triangular shape to the junction of paneling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete.Second class kail wood |
| 19 | Providing wood work in frames of doors, windows, clerestory windows and otherframes, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): 2nd class kail wood |
| 20 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including lSI marked M.S. pressed Butt hinges bright finished of required size with necessary screws excluding panelling which will be paid for separately,al!complete as per direction of engineer- in charge. Second class kail wood |
| 21 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. 12 mm thick Coir Veneer Board (conforming to IS: 14842) |
| 22 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.Second class Kail wood |
| 23 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-chargeSecond class Kail wood |
| 24 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete.Fixed to openings / wooden frames with rawl plugs screws etc. |
| 25 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete2nd class teak wood 50 x 12 mm |
| 26 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 27 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete. Size of tile 600x600 mm |
| 28 | Cement plaster in 1:6 ( 1 cement:6 fine sand ) 20 mm thick. |
| 29 | 15mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 30 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 31 | Providing and Applying white cement based putty of average thickness 2mm of approved brand and manufactured over the plastered wall surface to prepeare the surface even and smooth |
| 32 | Distampering with oil based bound washable distemper of approved brand and manufactured on wall surface new work ( two or more coar) ocer and including priming coat with cement primer |
| 33 | Applying priming coat With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 34 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work |
| 35 | Providing and fixing aluminium sliding door bolts ISI marked anodize ( anodic coating) not less than grade AC10 as per IS 1868) transpaent or dyed to required colour or shade with nuts and screw etc complete (300 x 16)mm |
| 36 | Providing and fixing Aluminium tower bolts ISI marked anidized (anodic coating) not less than grade AC 10 per IS 1868) transpaent or dyed to required colour or shade with screw etc complete (100 x 10 mm)mm |
| 37 | Providing and fixing Aluminium tower bolts ISI marked anidized (anodic coating) not less than grade AC 10 per IS 1868) transpaent or dyed to required colour or shade with screw etc complete (200 x 10)mm |
| 38 | Providing and fixing Aluminium hanging floor door stopper ISI marked anidized (anodic coating) not less than grade AC 10 per IS 1868) transpaent or dyed to required colour or shade Single rubber stopper. |
| 39 | Providing and fixing Aluminium handels ISI marked anidized (anodic coating) not less than grade AC 10 per IS 1868) transpaent or dyed to required colour or shade with nuts and screw etc complete 125mm |
| 40 | Providing and fixing Aluminium handels ISI marked anidized (anodic coating) not less than grade AC 10 per IS 1868) transpaent or dyed to required colour or shade with nuts and screw etc complete 100mm |
| 41 | Carriage of sandby Manual Means including loading , unloading & stacking complete lead upto 2000 m |
| 42 | Carriage of stone aggregate below 40 mm sizeincluding loading , unloading & stacking complete lead by Manual Labour upto 2000 m |
| 43 | Carriage of Stone by Manual means including loading , unloading & stacking complete lead upto 1000 mtr |
| 44 | Carriage of Cement by mechanical transport including loading , unloading & stacking complete lead upto 54 km and Manual Labour upto 4000 m |
| 45 | Carriage of Steel by mechanical transport including loading , unloading & stacking complete lead upto 54 km and Manual Labour upto 4000m |
| 46 | Carriage of CGI Sheets by mechanical transport including loading , unloading & stacking complete lead upto 54 km and Manual Labour upto 4000m |