| 1 | OD46832/2024-2025Dismantling wood plywood cladding including electrification items, labour etc.complete |
| 2 | 15.2.1Demolishing cement concrete manually / by mechanical means including disposal ofmaterial within 50 metres lead as per direction of Engineer - in-Charge.Nominalconcrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 3 | 15.7.4Demolishing brick work manually / by mechanical means including stacking ofserviceable material and disposal of unserviceable material within 50 metres lead asper direction of Engineer-in-Charge.In cement mortar |
| 4 | 2.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.All kinds of soil |
| 5 | 4.1.8Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4coarse sand : 8 graded stone aggregate 40 nominal size) |
| 6 | OD46894/2024-2025Earth filling using red earth including cost of all materials labour etc.complete |
| 7 | 5.9.1Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete |
| 8 | 5.9.6Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts |
| 9 | 5.1.2Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size |
| 10 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more |
| 11 | 12.45.3Providing and Fixing 15 mm densified tegular edged eco friendly light weightcalcium silicate false ceiling tiles of approved texture spintone /cosmos /Hexa orequivalent of size 595x 595 mm in true horizontal level, suspended on inter lockingmetal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqmincluding both side) consisting of main 'T' runner suitably spaced at jointsto get required length and of size 24x38 mm made from 0.33 mm thick (minimum)sheet, spaced 1200 mm centre to centre, and cross "T" of size 24x28 mmmade out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main'T' of size 24 x 28 mm made out of 0.33 mm (Minimum) sheet, 1200 mmlong spaced between main'T' at 600 mm centre to centre to form a grid of1200x600 mm and secondary cross 'T' of length 600 mm and size 24x28mm made of 0.33 mm thick (minimum) sheet to be inter locked at middle of the1200x600 mm panel to from grid of size 600x600 mm, resting on peripherywalls/partitions on a Perimeter wall angle pre-coated steel of size (24x24x3000 mmmade of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mmcentre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15mm thick densified edges calicum silicate ceiling tiles of approved texture (Spintone /Cosmos/hexa) in the grid, including cutting / making opening for services likediffusers, grills, light fittings, fixtures, smoke detectors etc., wherever require. Main'T' runners to be suspended from ceiling using G.I slotted cleats of size25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm G.I. adjustable rods with galvanised steel level clips of size of 85x30x0.8 mm,spaced at 1200mm centre to centre along main 'T' bottom exposed with 24 mm of all T- sections shall be pre-painted with polyster baked paint, for all heights, asper specifications, drawings and as directed by by engineer-in-charge. Note:- Onlycalcium silicate false ceiling area will be measured from wall to wall. No deductionshall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tiles shall have NRC. value of 0.50 (Minimum), lightreflection > 85% non - combustible as per B.S. 476 part IV, 100% humidityresistance and also having thermal conductivity < 0.043 w/m 0 KC. |
| 12 | 13.80Providing and applying white cement based putty of average thickness 1 mm, ofapproved brand and manufacturer, over the plastered wall surface to prepare thesurface even and smooth complete |
| 13 | 13.83.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC(Volatile including applying additional coats wherever required to achieve even shadeand colour.Two coats |
| 14 | 10.25.2Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixingin position and applying a priming coat of approved steel primer using structural steeletc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates andsimilar works |
| 15 | 10.16.1Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished welded type tubes |
| 16 | 13.52.1Finishing with Epoxy paint (two or more coats) at all locations prepared and appliedas per manufacturer's specifications including appropriate priming coat,preparation of surface, etc. complete.On steel work |