| 1 | Replacement of existing old defective electrical wiring installation & fitments of Single Rooms, Suites, Kitchen & Dinning hall of Bachelor Mess. |
| 2 | Taking down carefully copper /aluminium point wiring ( Light, Fan, Sockets or Power) complete (fitting such as switches , ceiling roses, pendantts, regulator sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site if required and making good disturbed surfaces of walls, floors, etc. with cement plastering, painting etc. |
| 3 | Taking down carefully by unscrewing from boards/outlet boxes, fittings and fixtures such as swithces, sockets, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse). |
| 4 | M & L for 6 Amp, Piano Switch, Flush Type, Single Pole, One Way. The material to be used shall be of ISI marked & any reputed make like Anchor, Cona, Havells, Polycab, V-Guard, Crabtree, Schneider Electric, Legrand. |
| 5 | M & L for 16 Amp, Piano Switch, Flush Type, Single Pole, One Way. The material to be used shall be of ISI marked & any reputed make like Anchor, Cona, Havells, Polycab, V-Guard, Crabtree, Schneider Electric, Legrand. |
| 6 | M & L for Socket Outlet, 2 in 1, 3 Pin, 6/16 Amp Flush Type. The material to be used shall be of ISI marked & any reputed make like Anchor, Cona, Havells, Polycab, V-Guard, Crabtree, Schneider Electric, Legrand. |
| 7 | M & L for Socket Outlet, 2 in 1, 3 Pin, 6 Amp Flush Type. The material to be used shall be of ISI marked & any reputed make like Anchor, Cona, Havells, Polycab, V-Guard, Crabtree, Schneider Electric, Legrand. |
| 8 | M & L for ceiling rose, 3 Pin, PVC/ Polycarbonate, Isolated Body. The material to be used shall be of ISI marked. |
| 9 | Material & Labour for point wiring with FRLS single core copper conductor cables of size 1.5 sq.mm in PVC conduit for one light point or fan point or exhaust fan point or call bell point controlled by one switch. Cutting chases for concealed conduit wiring will be measured separately. The rate do not include supply & fixing of electric fittings & accessories such as ceiling roses, lamp holders, socket outlets, switches, call bells etc. The wiring material to be used shall be of ISI marked & of reputed make like Havells, V-Guard, Polycab, Finolex, Anchor, Cona, KEI, RR Cables. |
| 10 | Material & Labour for point wiring with FRLS single core copper conductor cables of size 1.5 sq.mm in PVC conduit for one light point or fan point or exhaust fan point or call bell point controlled by two 2 way switch. Cutting chases for concealed conduit wiring will be measured separately. The rate do not include supply & fixing of electric fittings & accessories such as ceiling roses, lamp holders, socket outlets, switches, call bells etc. The wiring material to be used shall be of ISI marked & of reputed make like Havells, V-Guard, Polycab, Finolex, Anchor, Cona, KEI, RR Cables. |
| 11 | Material & Labour for point wiring with FRLS single core copper conductor cables of size 2.5 sq.mm in PVC conduit for one 3 pin 5 amps socket outlet independent .Cutting chases for concealed conduit wiring will be measured separately. The rate do not include supply & fixing of electric fittings & accessories such as ceiling roses, lamp holders, socket outlets, switches, call bells etc. The wiring material to be used shall be of ISI marked & of reputed make like Havells, V-Guard, Polycab, Finolex, Anchor, Cona, KEI, RR Cables. |
| 12 | Material & Labour for point wiring with FRLS single core copper conductor cables of size 4 sq.mm in PVC conduit for one 3 pin 15 amps socket outlet independent .Cutting chases for concealed conduit wiring will be measured separately. The rate do not include supply & fixing of electric fittings & accessories such as ceiling roses, lamp holders, socket outlets, switches, call bells etc. The wiring material to be used shall be of ISI marked & of reputed make like Havells, V-Guard, Polycab, Finolex, Anchor, Cona, KEI, RR Cables. |
| 13 | Suuply & fixing of wiring for circuit/sub-main wiring with 2 x 1.5 Sq. mm + 1 x 1.5 Sq. mm alongwith earth wire and FRLS PVC insulated copper conductor ,single core cable in surface/recessed (concealed) in PVC conduit as required. The materials to be used shall be of ISI marked and any reputed make like polycab, v-guard, finolex, havells etc. Cutting chases for recessed or concealed conduit wiring will be measured separately. The wiring material to be used shall be of ISI marked & of reputed make like Havells, V-Guard, Polycab, Finolex, Anchor, Cona, KEI, RR Cables. |
| 14 | Suuply & fixing of wiring for circuit/sub-main wiring with 2 x 2.5 Sq. mm + 1 x 2.5 Sq. mm alongwith earth wire and FRLS PVC insulated copper conductor , single core cable in surface/recessed (concealed) in PVC conduit as required. The materials to be used shall be of ISI marked and any reputed make like polycab, v-guard, finolex, havells etc. Cutting chases for recessed or concealed conduit wiring will be measured separately. The wiring material to be used shall be of ISI marked & of reputed make like Havells, V-Guard, Polycab, Finolex, Anchor, Cona, KEI, RR Cables. |
| 15 | Suuply & fixing of wiring for circuit/sub-main wiring with 2 x 4 Sq. mm + 1 x 4 Sq. mm alongwith earth wire and FRLS PVC insulated copper conductor , single core cable in surface/recessed (concealed) in PVC conduit as required. The materials to be used shall be of ISI marked and any reputed make like polycab, v-guard, finolex, havells etc. Cutting chases for recessed or concealed conduit wiring will be measured separately. The wiring material to be used shall be of ISI marked & of reputed make like Havells, V-Guard, Polycab, Finolex, Anchor, Cona, KEI, RR Cables. |
| 16 | Suuply & fixing of wiring for circuit/sub-main wiring with 2 x 6 Sq. mm + 1 x 6 Sq. mm alongwith earth wire and FRLS PVC insulated copper conductor , single core cable in surface/recessed (concealed) in PVC conduit as required. The materials to be used shall be of ISI marked and any reputed make like polycab, v-guard, finolex, havells etc. Cutting chases for recessed or concealed conduit wiring will be measured separately. The wiring material to be used shall be of ISI marked & of reputed make like Havells, V-Guard, Polycab, Finolex, Anchor, Cona, KEI, RR Cables. |
| 17 | Supply & fixing of exhaust fan, steel body , with fixing arrangements, AC single phase, 230V of Size 250 MM Sweep with blades and frame and louvers. |
| 18 | S & F of 25 A , Double Pole, RCCB with sensitivity current 30 mA to be fixed in the existing MCB DB complete with connections, testing and commissioning etc. as required for earth leakage protection. Thematerial to be used shall be of ISI marked & of reputed make like Havells, V-Guard, Polycab, Finolex, Anchor, Cona, Legrand, L&T etc. |
| 19 | S & F of 40 A , Double Pole, RCCB with sensitivity current 30 mA to be fixed in the existing MCB DB complete with connections, testing and commissioning etc. as required for earth leakage protection. Thematerial to be used shall be of ISI marked & of reputed make like Havells, V-Guard, Polycab, Finolex, Anchor, Cona, Legrand, L&T etc. |
| 20 | M & L for rigid non metallic PVC junction boxes of 1 to 4 way with external dia of 25 mm as per requirement. |
| 21 | M & L for rigid non metallic PVC junction boxes of 1 to 4 way with external dia of 32 mm as per requirement. |
| 22 | Material & Labour for 3 core PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 Volts Grade, Cross-Sectional Area, 25 Sq. MM. The material to be used shall be conforming to relevant IS standards. |
| 23 | Material & Labour for 40 MM Dia Low Density Polyethylene (LDPE) pipes in complete to fix in walls, ceiling ,in floors in trenches. |
| 24 | Labour for excavating trenches in hard/dense soil not exceeding 1.5 m wide & not exceeding 1.5 m depth for laying of electrical power cable and getting earth out. |
| 25 | Labour for returningthe excavated earth in trench including spreading, levelling & well ramming in layers not exceeding 25 cm. |
| 26 | Demolition of cement concrete of any description & in any position not otherwise specifically provided for. |
| 27 | Material & Labour for cement concrete of type C2 (1:3:6) with 40 mm graded aggregate in making cable trenches for power cable. |
| 28 | Cutting chases for concealed conduit wiring with cutting not exceeding 10 cm girth & making goodwith cement mortar 1:3 & paint as required. |
| 29 | S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet as required. The material shall be ISI marked and of reputed make like Cona, Anchor, Havells, Polycab, V-Guard etc. |
| 30 | Supplying & fixing metal box of 100mm x 100mm x 60 mm deep in recess with suitable size phenolic laminated sheet cover in front including painting etc. as required. |
| 31 | Supplying & fixing metal box of 180mm x 100mm x 60 mm deep in recess with suitable size phenolic laminated sheet cover in front including painting etc. as required. |
| 32 | Supplying & fixing metal box of 200mm x 125mm x 60 mm deep in recess with suitable size phenolic laminated sheet cover in front including painting etc. as required. |
| 33 | Supplying & fixing 2 way 5/6 A piano type switch on the existing switch box/cover including connections etc. as required. |