| Sl. No. | Item Description |
| 1 | Civil and Services WorkEarth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed as directed by Engineer-in- charge. |
| 2 | All kinds of soil |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming & watering, lead up to 50 m and lift upto 1.5 m. |
| 4 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 5 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. - Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 6 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 7 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 8 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 9 | Demolishing stone pitching in floors, slopes, etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 10 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 11 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 12 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 13 | Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete. |
| 14 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 15 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. |
| 16 | With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 |
| 17 | With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 18 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 19 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 20 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note : Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). |
| 21 | All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 22 | All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 23 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 24 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator, vacuum dewatering process and finally finished by floating, brooming with wire brush etc. All complete including shutting, channel, etc. as per specifications and directions of Engineer-incharge. |
| 25 | Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) : |
| 26 | 400 mm dia piles |
| 27 | 500 mm dia piles |
| 28 | Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/ Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. |
| 29 | Single pile upto 50 tonne Safe capacity Initial test (Test Load 2.5 times the Safe capacity) |
| 30 | Single pile upto 50 tonne Safe capacity Routine test (Test Load 1.5 times the Safe capacity) |
| 31 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete for all lift and level |
| 32 | Thermo-Mechanically Treated bars (Fe500d) |
| 33 | Centering and shuttering including strutting propping etc, and removal of form for: |
| 34 | Foundations, footings, bases of columns etc., for mass concrete |
| 35 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 36 | Suspended floors, roofs, landings, balconies and access platform |
| 37 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 38 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 39 | Providing & making Gabion structure with Mechanically Woven Double Twisted Hexagonal Shaped Wire mesh Gabion Boxes as per IS 16014:2012, MORTH Clause 2500, of required size, Mesh Type 10x12 (D=100 mm with tolerance of ±2%), Zinic+10% Al alloy+PVC coated, Mesh wire diameter 2.7/3.7 mm (ID/OD), mechanically edged/ selvedged with partitions at every 1m interval and shall have minimum 10 numbers of openings per meter of mesh perpendicular to twist, tying with lacing wire of diameter 2.2/3.2 mm(ID/OD), supplied @3% by weight of Gabion boxes, filled with boulders with least dimension of 200 mm, as per drawing, all complete as per directions of Engineer-in-charge. |
| 40 | Providing and laying needle punched and mechanically bonded non-woven Geotextile of Type-III indigenously manufactured from high quality propylene staple fibers (continous filament will not be accepted) on the prepared subgrade for sepration. All complete as per directions of Engineer-in-charge. |
| 41 | Supplying and filling of Boulder of approx. size 150 to 250 mm or as per site condition and requirement behind Gabion boxes, in trenches, plinth, sides of foundation etc. complete. All complete as per directions of Engineer-in-charge. |
| 42 | Providing and fixing self drilling anchors of 32 mm diameter for intermediate anchor with yield load of 230 kN and tensile Number strength > 550 N/millimeter 2, with attached drill bit of D51 dia bottom for rock, hexagonal nut of 400 Kn capacity, washer plate 150 x 150 x 8 millimeter size, coupler for connecting bars, inserting quick fixing cement resin and full length grouting including all ancillary works for intermediate (Cortical) anchoring including all ancillary material, machinery, labour etc. complete and as directed by Engineer-in-charge. |
| 43 | Brick work with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 44 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: |
| 45 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 46 | 12 mm cement plaster of mix : |
| 47 | 1:4 (1 cement: 4 coarse sand) |
| 48 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 49 | 1:4 (1 cement: 4 coarse sand) |
| 50 | Finishing with Acrylic smooth exterior paint of required shade: New work (two or more coat applied @ 1.67 ltr/10 sqm. Over and including priming coat of exterior primer applied @ 0.90 Lt./ 10 sqm.) |
| 51 | Finishing with Acrylic smooth exterior paint with Silicone additives of required shade: New work (two or more coat applied @ 1.43 ltr/10 sqm. Over and including priming coat of exterior primer applied @ 0.90 Lt./ 10 sqm.) |
| 52 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 53 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. |
| 54 | Providing & mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck, using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer’s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of selfhealing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. |
| 55 | Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/ honey-comb area of concrete/ masonry by suitable gun/ pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) |
| 56 | Stirrer mixed SBR Polymer (of approved make) modified Cement slurry made with Shrinkage Compensating Cement in concrete/ RCC work. |
| 57 | Epoxy injection grout in concrete/RCC work of approved make |
| 58 | 50 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. (At riser and skirting also) |
| 59 | Red sand stone - 50mm |
| 60 | White sand stone - 50mm |
| 61 | Extra for pre finished nosing in treads of steps of Kota stone/ sand stone / granite. |
| 62 | Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. |
| 63 | Kota stone (25mm thick) slab flooring over 20 mm (avg) thick base laid over & jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing & polishing complete with base of cement mortar 1:4 (1 cement :4 coarse sand): |
| 64 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 65 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.- Polished Granite stone slab of approved colour |
| 66 | Providing and laying gang saw cut, mirror polished pre-moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. |
| 67 | Granite 30mm thick of any colour and shade |
| 68 | Extra for sand blasted finish over granite stone as per design requirement. |
| 69 | Extra for 150x150mm or below size cutting in granite stone flooring as per design requirement. |
| 70 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling I grouting and finishing complete as perdirection of Engineer-in-charge. |
| 71 | Size ofTile 100x100 mm |
| 72 | Size ofTile 150x150 mm |
| 73 | Providing and fixing Natural Stone tiles (of approved size and sample) on finished plain wall surface of approved size in all colour, design, fixing in customize design as per direction of Engineer-in- Charge. The tiles to be fixed on the floor & wall with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of joints with cement based polymer grout (as per specified by the approved manufacturer). The rate is inclusive of all operation, material and required pattern approved by Architect and Engineer-in-Charge. (Base rate is Rs. 850/- per sqft.) Make: Keramos or approved equivalent. |
| 74 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : |
| 75 | Red sand stone - exposed face fine dressed with roughbacking - 30mm thick |
| 76 | White sand stone - exposed face fine dressed with roughbacking - 30mm thick |
| 77 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. |
| 78 | Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. |
| 79 | Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge.(The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). |
| 80 | White sand stone - 30mm thick gang saw cut stone |
| 81 | White sand stone - 30mm thick gang saw cut stone |
| 82 | Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) of size 300x230x300 mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/ RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Architect/ Engineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/ planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). |
| 83 | Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge. |
| 84 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1and M.S. top cover of required thickness for rolling shutters. |
| 85 | 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 86 | Providing and fixing ball bearing for rolling shutters. |
| 87 | Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. |
| 88 | Providing and fixing stainless steel (Grade 304) railing, gate, etc. (Matt / Glossy finish) made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 89 | Designing, providing and installation of Solid Stone column of size 350mm dia x 3000mm high (height incl. square base of 450mm x 450mm x 600mm ht.)inclusive of carving, embossing, engraving, insertion, etc. over stone work as per approved design based on Client/ Architect\"s input. (Foundation works is in civil scope) All complete including consumables, framing work required for installation as per approved shop drawing, sample and directed by Architect/ Engineer-in-charge. (refer reference drg.) |
| 90 | Designing, providing and installation of Stone Chattri of size 3000mm x3000mm x3000mm Height (Clear internal size) with Shikhar above 3000mm inclusive of carving, embossing, engraving, insertion, etc. over stone work as per approved design based on Client/ Architect\"s input. (Foundation works is in civil scope) All complete including consumables, framing work required for installation as per approved shop drawing, sample and directed by Architect/ Engineer-in-charge. (refer reference drg.) |
| 91 | Providing and applying silicone based water repellent coating confirming to BS: 6477-1984 in 2 coats with a consumption of 6 sq.mtr/ litre per coat over the exposed surface including cleaning the surface making it free from dirt, oil grease, wax and all other contamination using mechanical tool, wire brush, compressed air followed by water washing and as per the manufacturer specification and direction of Engineer-in-charge. |
| 92 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 93 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 94 | Supply and installation of 4000mm Florian pole made of circular mild steel pipe of two section (grade YST 210) Bottom section 139.7mm Dia x 3.6mm thick with 1200mm Height & Top section 76.1mm Dia x 2.6mm thick with 2695mm Height. On the top of the pole a decorative flower arrangment as shown in the image. Decorative base made of Gravity Die-cast aluminium (436mm Dia x 481mm Height). Decorative Die- cast Aluminium cone (180mm Dia x 175mm Height) covered on the both section joint area. Pole section welded by certified welders using high end MIG welding processes. PDC aluminium service door 348mm height x 110mm width shall be provided with the company logo embossed on the bottom of the door and safety rope. The control gear tray is prewired with 2.5 Sq.mm cable, 6A SP MCB and 32A Ramanuj stud type 4 way terminal block for loop-in / loop-out arrangement, 5A 2 Way terminal connector and provision for earthing. |
| 95 | Any other internal cables and connections shall not be covered in the scope of supply. Mild steel mounting plate 200mm Square x 12mm thick Steel of grade E250 to IS 2062 : 2011 with 4 elongated holes 38 x 19 to suit M16 x 300mm bolts of grade 4.6 at CC 140. The base plate have a cable entry hole of 70mm dia at the center. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. All dimension are within +/- 5% tolerance. After fabrication, entire pole is shot blasted (Inhouse). The pole is coated with zinc rich primer & pure polyester powder coating or epoxy zinc phosphate primer and finished using environmentally stable polyurethane based paint (coating thickness 60-80 microns). The Pole shall be provided with Graphite grey / Anthracite grey / Black as standard colour options. All complete including consumables required for installation. Sample should be submitted for approval from Architect/ Engineer-in-charge. Make K-lite/ Unilamp/ Ligman |
| 96 | Supply and installation of 45-50W Post top with LED 3000K, 4000K, 5700K 240Vac CRI >80 MacAdam step 3 Dimension not less than Ø400 x 807 mm, Light Distribution360° Electronic driver ON/OFF, IP rating IP65, Spun aluminium top cover Ø400 mm of 1.6mm thickness, die cast aluminium decorative knob on top, Mild steel (Sand Blasting with zinc primer supporting arm integrated with die-cast aluminium base suitable for mounting Ø76mm OD pipe. SS fasteners. Pure polyester powder coated process : Acid treatment & pure polyester powder coating. Clear acrylic diffuser with controlled downward light emission. Lamp fixed position. Lumen efficacy should be minimum 120lm/W. This luminaire should contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire >56,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >88%, power factor >0.96, THD <10%, Surge protection 6KV. All complete including consumables required for installation. Sample should be submitted for approval from Architect/ Engineer-in-charge. Make: K-Lite/ Unilamp/ Philips |
| 97 | Supply and installation of Surface mounted LED linear with system power [20W ± 5%], should be available in 3000K/4000K/6000K color temperature, maximum dimesnion 1200 x 43 x 52mm should be made up of High-Grade Aluminium with Die-cast Endcaps, Diffuser/ Lens Material : Polycarbonate, Secondary : Hexa-Cell (Matt Black), UGR<16, dali dimmable driver operational voltage range of 90-265V, power factor > 0.9, THD < 10%, Inbuilt surge protection of 3 KV, Luminaire has Ingress protection ofIP20. The luminaire should have minimum lumen outputof 100lm/W, CRI of >80. The LEDs used have a life of 50,000 burning hrs Lumen maintenance as per L70B10 with SDCM<=3 binning Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs - LEDs of CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG/ LUMILED / NICHIA/ CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Architect/ Engineer-in-charge. Make: K-Lite/ Unilamp/ ligman |
| 98 | Supply and installation of White 3000K 9W LED In-ground with in built honey comb louvre symmetrical luminaire made up of die-casting with Ø116 x 153mm,the Ø116 front ring should be made up of stainless steel 316 grade front ringwith silicone black gasket and toughened clear glass diffuser. The luminous flux of the luminaire is upto 428 lm for 3000K BEAM - 15°/ 25°/ 40°. The ingress protection is IP67 and impact resistance of IK08. The luminaire is integrated with high power CITIZEN COB with CRI≥80, SDCM≤3, L70/ B10 @ 60000 Hrs. The integral constant current driver comes with the power factor greater than or equal to 0.9, total harmonic distortion less than 15% with operating efficiency greater than 80% and a surge protection of 2KV. The driver input voltage 240Vac at 50-60Hz, operating voltage of 100-277Vac and operating temperature of -20˚ ~ +40˚C.Adequate heat sink with proper thermal management shall be provided. Operating Humidity : 10%-90%. THD should be less than 10%. The fixtures proposed must have passed LM 79 & LM-80, Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs -LEDs of CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG/ LUMILED / NICHIA/ CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Architect/ Engineer-in-charge. Make: K-Lite/ Unilamp/ ligman |
| 99 | Supply and installation of Static White 3000K surface mounted compact spot light designed to provide directional light. Beam angle 15° / 25° / 40°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. Clear toughened glass of 4mm thickness. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression.Power consumption should be between 10W to 12W at steady state full intensity luminaire should have minimum luminous flux of 1054 Lm. Color rendering index CRI ≥ 80 and power factor of complete luminaire ≥ 0.90, at white colour.Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP65/66. Mechanical resistance IK06. Pure polyester powder coated graphite grey / anthracite grey / jet black. Available colour temperature 3000K / 4000K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire 113 x 84 x 117mmmm. Adequate heat sink with proper thermal management shall be provided. Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%. THD should be less than 10%. Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities Make of LEDs -LEDs of CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG/ LUMILED /NICHIA/CITIZEN, the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of materialCE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Architect/ Engineer-in-charge. Make: K-Lite/ Unilamp/ ligman |
| 100 | Supply and installation ofDecorative Pole Height 6M with Cast Iron Base made of circular mild steel pipe of two section (ISI Marked, grade YST 210), Bottom section & Top section 114.3mm Dia x 3mm thick respectively. Decorative Golden ring made of Die cast Aluminium at jointing section of two pipes (230mm Dia x 250mm Height) . Decorative base made of Gravity Die-cast aluminium or CI base approximately A/f 420mm and 966mm Height. Wind speed considered in design 50 m/sec in compliance with IS 875 Part 3 : 1987. Wind pressure calculation as per IS 875(part-3) & structural calculation report certified by any Government Institution as per EN40 should be submitted to verify the pole design. Pole section welded by certified welders using high end MIG welding processes. PDC aluminium service door 348mm height x 110mm width shall be provided with the company logo embossed on the bottom of the door and safety rope with IP protection rating. The Double arm pelican jesy bracket is a split constructed type, Bracket stem made of MS Pipe 60.3mm Dia x 2.6mm thick, emerging from a Gravity Diecast Aluminium embellishments. The Bracket is crowned at top with CNC cut Chakra of Appropriate size. The artistically curved single arm made of MS pipe 38.1mm Dia x 2mm thick, with gravity diecast aluminium leaves Shaped embellishment, is firmly held to the stem by way of MS clamps and the arm bears cast iron knobs at one end and other ends facilitates the fitment of luminaire at 800mm on either side from the vertical axis of the bracket stem, it should be highlighted with 6W surface mounted compact spot light designed to provide directional light. Beam angle 15° / 25° / 40°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. Clear toughened glass of 4mm thickness. Surface mounting spike made of polypropylene black. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP65. Mechanical resistance IK06. Pure polyester powder coated graphite grey / anthracite grey / jet black. Available colour temperature 3000K / 4000K / 5700K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. The control gear tray is prewired with 2.5 Sq.mm cable,6A MCB and 32A terminal connectors for loop-in / loop-out arrangement. Any other internal cables and connections shall not be covered in the scope of supply. Mild steel mounting plate of round shape with 280x 12mm thick Steel of grade E250 to IS 2062 : 2011 with 4 elongated holes 38X19 to suit M16 x 500mm bolts of grade 4.6 at CC230. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. All dimension are within +/- 10% tolerance. Shot blasting process for surface preparation of pole before painting / powder coating is required. The manufacturer should have in-house shot blasting machine and salt spray testing equipment. Test report should be submitted. The pole is coated with zinc rich primer & pure polyester powder coating or epoxy zinc phosphate primer and finished using environmentally stable polyurethane based paint of desired RAL (coating thickness 60-80 microns).All complete including consumables required for installation. Sample should be submitted for approval from Architect/ Engineer-in-charge. Make: K-Lite/ vakrangee/ ligman |
| 101 | Supply and installation of pendent type 50W LED, pendant mounted compact street light. Asymmetrical light distribution. Decorative luminaire made of pressure die cast aluminium body of high corrosion resistance and non corrosive stainless steel fasteners. Clear toughened glass diffuser of 5mm thickness. The module have polycarbonate optical lens with extruded aluminium heatsink for thermal management with vertical fin design for longer life of the LEDs. Slight regressin the optical assembly for better glare control. The mounting arrangement nipple, coupling & Hex nut made of Stainless steel 304 suitable for mounting to internally threaded pipe of designation M30. Protection class IP65. Mechanical resistance IK10. Pure polyester powder coated RAL 9004 Signal black, RAL 9007 Grey aluminium, RAL 7016 Anthracite grey. Available colour temperature 3000K / 4000K / 5700K, Colour rendering index (CRI)>70. SDCM-3 MacAdam. LED module with expected service life of at least 1,00,000 operating hours with luminous efficacy of 140 lm/W at 4000K and with T-IV optics. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >85%, Power factor >0.95, THD <10%, Surge protection 6KV. Make of LEDsof CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG/ LUMILED / NICHIA/ CITIZEN. Luminaire dimension Should not be more than : 490mm diameter x 160mm height. Manufacturer must have inhouse NABL certified lab equipped with photo goniometer, IP, IK test facilities CE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Architect/ Engineer-in-charge. Make: K-Lite/ Unilamp / ligman |
| 102 | Supply and installation of 12W square decorative leser cut designer bollard LED 3000K, 4000K, 6500K 230-240Vac CRI >80 MacAdam step-3 Height910mm Light DistributionSymmetrical, Electronic driver ON/ OFF LUMINAIRE TYPE Bollard. IP rating IP66, Extruded square aluminium tube (grade 6063 with test certificate) Sq. 150 x 3mm thickness. Should have Bespoke laser cutting design options. SS fasteners. Must be equipped with Pre treated epdm black gaskets. Should have Die-cast aluminium mounting plate Sq.150 x 4mm thick with 3 elongated holes 20 x 12 to suit M10 bolts at PCD 90 with pure polyester powder coating. This mounting plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foudation. Hot dip galvanised foundation bolt. Mechanical resistance IK06. It should be Pure polyester powder coated process: Acid treatment & pure polyester powder coating. Optical grade clear toughened glass diffuser of 4mm thickness with controlled downward light emission. Lamp fixed position. This luminaire should contains built-in IP 65 LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >85%, power factor >0.9, THD <10%, Surge protection 2.5KV. Manufacturer must have inhouse NABL certified lab equipped with photo goniometer, IP, IK test facilities. All complete including consumables required for installation. Sample should be submitted for approval from Architect/ Engineer-in-charge. Make: K-Lite/ Unilamp / ligman |
| 103 | Supply and installation of IP67 Rated Profile Step Light, Input power : 8W, 3000K, 24Vdc CRI >80 MacAdam step 3. Mechanical Impact resistant upto IK10, Dimension not more than 1000 x 12 x 7mm. Beam angle : 120° (Diffused), Electronic driver ON/OFF (External driver), High-Grade aluminum & Endcaps, Polyurethane Encapsulation diffuser. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire >60,000 hours at 40°C. Operating ambient temperature range is from -25°C to +55°C. Driver efficiency >85%, Surge protection 3KV. CE and BIS approved. Inclusive of Waterproof Electronic Driver IP67 rated. All complete including consumables required for installation. Sample should be submitted for approval from Architect/ Engineer-in-charge. Make: K-Lite/ Unilamp / ligman |
| 104 | Supply and installation of Input power : 12W Ceiling-mounted compact down light emission designed to use monochromatic Warm white (3000K) & Neutral white (4000K). Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Extruded aluminium section with inner grooves to fix the top and bottom frame (grade 6063) Ø100 x 3mm thickness, die-cast aluminium glass fixing frame Ø100mm with clear toughened glass diffuser of 4mm thickness with ceramic black coated on outer corner siliconed to frame & die-cast aluminium cover for surface mounting on ceiling Ø106mm (ADC12). Die-cast aluminium heat sink for excellent thermal management. Single cable entrance via black M10 cable gland (SS). All external screws are made of stainless steel. Clear silicone gasket.Protection class IP65. Mechanical resistance IK07. Acid treatment & pure polyester powder coated graphite grey / anthracite grey / jet black. The luminaire\"s built-in LED module are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21). Operating ambient temperature range is from -15°C to +50°C. Beam angle 15° / 25° / 40°, Colour rendering index (CRI)>80. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >85%, Power factor >0.95, THD <10%, Surge protection 2.5KV. Manufacturer must have inhouse NABL certified lab equipped with photo goniometer, IP, IK test facilities. Luminaire square 106mm x height 150mm. CE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Architect/ Engineer-in-charge. Make: K-Lite/ Unilamp / ligman |
| 105 | Supply and installation of White 3000K 1W In-ground with in built honey comb louvre symmetrical luminaire made up of die-casting withØ34 x 62 mm,the Ø34front ring should be made up of stainless steel 316 grade front ringwith silicone black gasket and toughened clear glass diffuser. The luminous flux of the luminaire is upto 169.06 lm for 3000K BEAM - 40. The ingress protection is IP67 and impact resistance of IK06. The luminaire is integrated with high power CITIZEN COB with CRI≥80, SDCM≤3, L70/ B10 @ 60000 Hrs. The integral constant current driver comes with the power factor greater than or equal to 0.9, total harmonic distortion less than 15% with operating efficiency greater than 80% and a surge protection of 2KV. The driver input voltage 240Vac at 50-60Hz, operating voltage of 100-277Vac and operating temperature of -20˚ ~ +40˚C. Adequate heat sink with proper thermal management shall be provided. Operating Humidity : 10%-90%. THD should be less than 10%. The fixtures proposed must have passed LM 79 & LM-80, Reports from NABL laboratory will be submitted post the issuance of LOA to the successful bidder and before the supply of material. Make of LEDs -LEDs of CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG/ LUMILED /NICHIA/CITIZEN. CE & BIS Certified. Manufacturer must have inhouse NABL certified lab equipped with photo goniometer, IP, IK test facilities. All complete including consumables required for installation. Sample should be submitted for approval from Architect/ Engineer-in-charge. Make: K-Lite/ Unilamp / ligman |
| 106 | Supply and installation of Input power : 12WCeiling-mounted compact down light emission designed to use monochromatic Warm white (3000K) & Neutral white (4000K). Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Extruded aluminium section with inner grooves to fix the top andbottom frame (grade 6063) ?100 x 3mm thickness, die-cast aluminium glass fixing frame ?100mm with clear toughened glass diffuser of 4mm thickness with ceramic black coated on outercorner siliconed to frame & die-cast aluminium cover for surface mounting on ceiling ?106mm (ADC12). Die-cast aluminium heat sink for excellent thermal management. Single cable entrance via black M10 cable gland (SS). All external screws are made of stainless steel. Clear silicone gasket. Protection class IP65. Mechanical resistance IK07. Acid treatment & pure polyester powder coated graphite grey / anthracite grey / jet black. The luminaire\"s built-in LED module are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21). Operating ambient temperature range is from -15°C to +50°C. Beam angle 15° / 25° / 40°, Colour rendering index (CRI)>80. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >85%, Power factor >0.95, THD <10%, Surge protection 2.5KV. Manufacturer must have inhouse NABL certified lab equipped with photo goniometer, IP, IK test facilities . Luminaire square 106mm x height 150mm. CE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Architect/ Engineer-in-charge. Make: K-Lite/ Unilamp / ligman |
| 107 | Supply and installation of6W, Wall-mounted compact down light emission designed to use monochromatic Warm white (3000K) & Neutral white (4000K). Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Extruded aluminium section with inner grooves to fix the top and bottom frame (grade 6063) Ø100 x 3mm thickness, die-cast aluminium glass fixing frame Ø100mm with clear toughened glass diffuser of 4mm thickness with ceramic black coated on outercorner siliconed to frame & die-cast aluminium top closing frame Ø100mm (ADC12). Die-cast aluminium heat sink for excellent thermal management. Single cable entrance via black PG7 cable gland, Die cast aluminium base for surface mounting on wall (ADC12). All external screws are made of stainless steel. Clear silicone gasket. Protection class IP65. Mechanical resistance IK07. Acid treatment & pure polyester powder coated graphite grey / anthracite grey / jet black. The luminaire\"s built-in LED module are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21). Operating ambient temperature range is from -15°C to +50°C. Beam angle 15° / 25° / 40°, colour rendering index (CRI)>80. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.90, THD <10%, Surge protection 2.5KV. Manufacturer must have inhouse NABL certified lab equipped with photo goniometer, IP, IK test facilities Luminaire dimension : 150mm length x 100mm width x 150mm height. CE & BIS Certified. All complete including consumables required for installation. Sample should be submitted for approval from Architect/ Engineer-in-charge. Make: K-Lite/ Unilamp / ligman |
| 108 | Trenching in ordinary soil up to a depth of cm including removal and stacking of serviceablematerials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/ and manure before and after flooding trench with water (excluding cost of imported earth, slude or manure). |
| 109 | Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manureafter reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking anddisposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately). |
| 110 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 part ofstacked volume of earth after reduction by 20% :1 part of stacked volume of manure after reductionby 8%) flooding with water, dressing including removal ofrubbish and surplus earth, if any with allleads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Holes 120 cm dia, and 120 cm deep |
| 111 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1byvolume(2partofstackedvolumeofearthafter reduction by 20% :1 part of stacked volume of manure after reductionby8%)floodingwithwater,dressingincluding removalofrubbishandsurplusearth,ifany withallleads andlifts(costofmanure,sludgeorextragoodearthif needed to be paid for separately)Holes60 cm dia , and 60 cm deep |
| 112 | Supplying and stacking of cow dung manure/cattle manure atsite including cost and carriage with all lead and lifts, (manuremeasured in stacks will be reduced by 8% of payment) |
| 113 | Supplyingand spreading of fertilizer & pesticides at site of work DAP |
| 114 | Mixing earth and sludge or manure in proportion specified or directed. |
| 115 | Spreading of sludge, dump manure or/ and good earth in required thickness (cost of sludge dump manure or/ and good earth to be paid separately) |
| 116 | Rough dressing the trenched ground including breaking of clods. |
| 117 | Providing and planting of Michelia champa (Golden Champa) of height 12\"-0\" in earthen pots of size 14\" as per direction of the Architect/ Engineer-in-charge. |
| 118 | Providing and planting of Tabernaemontana divaricata (Chandnidouble) of height 12\"-0\", bushy in big size HDPE bag as per direction of the Architect/ Engineer-in-charge. |
| 119 | Providing and planting of Azadirachta indica (Neem) of height 12\"-0\" in big polybag of size 14\" as per direction of the Architect/ Engineer-in-charge. |
| 120 | Providing and planting Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy in full bloom 4\".0\" ht. in 40 cm Cement Pot as per direction of the Architect/ Engineer-in-charge. |
| 121 | Providing and planting of Khair (Acacia auriculiformis) of 12\".0\" ht in bag size of 25 cm as per direction of the Architect/ Engineer-in-charge. |
| 122 | Providing and planting of Butea frondosa (Flame of Forest) of 12\".0\" height in big poly bags of size 25 cm as per direction of the engineer-in-charge. |
| 123 | Providing and planting of Euphorbia caracasana (bronze colour leaves) of 12\".0\" height, bushy in big size HDPE bag as per direction of the Architect/ Engineer-in-charge. |
| 124 | Providing and stacking of Terminalia arjuna of 12\".0\" height. in big polybags of size 25 cm as per direction of the Architect/ Engineer-in-charge. |
| 125 | Flooding the ground with water including making Kiaries and dismantelling the same |
| 126 | Grassing with selection no-1, grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing including supplying good earth if needed (the good earth shall be paid for separately) With grass Turf |
| 127 | Providing & laying Selection no. 1 doob grass turf with earth 100mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly, as per direction of Architect/ Engineer-in-charge. |
| 128 | Removal of garden rubbish including building rubbish, earth with or / and mulba excavated by mechanical transport with all lead and lift. |
| 129 | Supplying, Stacking & execution of Selection No.1 doob grass turf at site fresh lush green & free from weeds having proper roots in green with good andhealthy including loading, unloading, carriage, with all leads& lifts and all taxes paid etc. and as per direction of Architect/ Engineer-in-charge. |
| 130 | EXTERNAL DRAINAGE SYSTEM Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 80 m : |
| 131 | All Kinds of SoilPipes, cables etc., exceeding 80mm dia but not exceeding 300mm dia |
| 132 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : |
| 133 | 200 mm diameter |
| 134 | 250 mm diameter |
| 135 | 300 mm diameter |
| 136 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with RCC Top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix ( 1 cement :4 coarse sand: 8 graded stone aggregate 40 nominal size), inside plastering 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand),finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. |
| 137 | Inside size 90x80 cm and 50 cm deep including perforated C.I. / RCC cover with frame (Heavy duty) 455x610 mm internal dimensions |
| 138 | Inside size 120x90 cm and 90 cm deep including C.I./RCC cover with frame (heavy duty) 560 mm internal diamete |
| 139 | Providing & fixing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per I.S:10910 on 12 mm dia steel bar conforming to I.S:1786 having minimum cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 165 mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturer\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15cm cement concrete block 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size) complete as per design. |
| 140 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : |
| 141 | For pipes 300 to 350 mm diameter |
| 142 | For pipes 250 to 300 mm diameter |
| 143 | Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design : |
| 144 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 145 | LIGHT FITTINGANDFIXTURE WORKEarthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 146 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 147 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 148 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 149 | Supply, installation, testing and commissioning of indoor floor mounted/ wall mounted, IP42, factory built, modular, sectionalised, compartmentalized, extendable type LT cubicle panel of suitable size suitable for operation on 433/415 volts, 50 Hz AC 3 phase 4 wire supply system fabricated from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates with stiffeners wherever required, having vibration free structure chemically treated with seven tank process or better before painting for surface treatment and powder coated in approved shade, with suitable electrolytic grade high conductivity bus bars extensible, DMC/ SMC (whichever is superior) bus bar supports, with short circuit withstand capacity as mentioned, bottom base channel of section not less than 100mmX 50mmX 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm. PVC insulated FRLS copper conductor S/C cable for voltage & current respectively, including providing and fixing following switch gears and as per schedules, technical specifications etc.complete as required. |
| 150 | MAIN LT PANEL Incomer :MCCB 415V, 50Hz, 160A, 4P, 25kA for 1 sec rated thermal magnetic based MCCB with inbuilt LSIG protection- 1 Nos.Metering (1 No.) Multifunction meter with inbuilt selector switch for measurement of current, voltage, power factor, KVA, kVAh, KVArh, KVAR, frequency, ,KWHr (both line and phase) complete as per specificationsIndication lamps LED type phase indication lamps suitable for 230V,50Hz AC (red, yellow, blue) - 1 Set.LED type Indication lamps for breaker, suitable for 230V,50Hz AC supply (on, off, trip) - 1 set CTs:415V, 160/5A, 5VA, CL-1 current transformer for meteringBusbar : Busbar (1 Set - 4P + E)Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 250 A, 25 kA for 1 sec of required length and cross sectional area. Outgoing : MCCB3Nos. 415V, 50Hz, 100A, 4P, 25 kA MCCB.MCB11Nos. 415V, 50Hz, 63A, 4P, 10 kA MCB. |
| 151 | FEEDER PILLAR-1 Incomer :MCCB 415V, 50Hz, 100A, 4P, 25kA for 1 sec rated thermal magnetic based MCCB with inbuilt LSIG protection- 1 Nos.Indication lamps LED type phase indication lamps suitable for 230V,50Hz AC (red, yellow, blue) - 1 Set.LED type Indication lamps for breaker, suitable for 230V, 50Hz AC supply (on, off, trip) - 1 set Busbar : Busbar (1 Set - 4P + E)Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 150 A, 25 kA for 1 sec of required length and cross sectional area.Outgoing : MCB19Nos. 415V, 50Hz, 25A, DP, 10 kA MCB.5Nos. 415V, 50Hz, 32A, DP, 10 kA MCB. |
| 152 | FEEDER PILLAR-2Incomer :MCCB 415V, 50Hz, 100A, 4P, 25kA for 1 sec rated thermal magnetic based MCCB with inbuilt LSIG protection- 1 Nos.Indication lamps LED type phase indication lamps suitable for 230V,50Hz AC (red, yellow, blue) - 1 Set.LED type Indication lamps for breaker, suitable for 230V, 50Hz AC supply (on, off, trip) - 1 set Busbar : Busbar (1 Set - 4P + E)Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 150 A, 25 kA for 1 sec of required length and cross sectional area.Outgoing : MCB24Nos. 415V, 50Hz, 25A, DP, 10 kA MCB.6Nos. 415V, 50Hz, 32A, DP, 10 kA MCB. |
| 153 | Supplying following 1.1kV grade, heavy duty XLPE insulated, FRLS type armoured /Unarmured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete as required. |
| 154 | 3.5C x 70 sqmm aluminium conductor, A2XWY. |
| 155 | 3.5C x 35 sqmm aluminium conductor, A2XWY. |
| 156 | 4C X 10 sqmm copper conductor, 2XWY |
| 157 | 3C X 6 sqmm copper conductor, 2XWY |
| 158 | 3C X 4 sqmm copper conductor, 2XWY |
| 159 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 160 | 3½ X 70 sq. mm (38mm) |
| 161 | 3½ X 35 sq. mm (32mm) |
| 162 | Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 163 | 4C X 10 sqmm copper conductor, 2XWY (25mm) |
| 164 | 4C X 2.5 sqmm copper conductor, 2XWY(19mm) |
| 165 | 3C X 6 sqmm copper conductor, 2XWY(19mm) |
| 166 | 3C X 4 sqmm copper conductor, 2XWY(19mm) |
| 167 | 4C X 2.5 sqmm copper conductor (19mm) |
| 168 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 169 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 170 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 171 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 172 | CIVIL WORK CONSTRUCTION OF PUBLIC CONVENIENCESEarth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed as directed by Engineer-in- charge. |
| 173 | All kinds of soil |
| 174 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming & watering, lead up to 50 m and lift upto 1.5 m. |
| 175 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 176 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8km from the site of work and including watering dressing etc. Rate to include cost of all materials, labour and T&P etc. required for proper completion of the work. |
| 177 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 178 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : |
| 179 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 180 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) Damp proof course |
| 181 | Providing and laying Damp proof Course 50mm thick with cement concrete 1:2:4 (1 Cement: 2 Coarse sand :4 Graded stone aggregate 20mm nominal size) |
| 182 | Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 183 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 184 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. |
| 185 | All works upto plinth level |
| 186 | All works above plinth level upto floor V level |
| 187 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete for all lift and level |
| 188 | Centering and shuttering including strutting propping etc, and removal of form for: |
| 189 | Foundations, footings, bases of columns etc., for mass concrete |
| 190 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 191 | Suspended floors, roofs, landings, balconies and accessplatform |
| 192 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 193 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 194 | Brick work with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 195 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 196 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: |
| 197 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 198 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 199 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 200 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 201 | Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). |
| 202 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 203 | Second class teak wood |
| 204 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : |
| 205 | Second class teak wood |
| 206 | Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). |
| 207 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces ofshutters. |
| 208 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 209 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 210 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : |
| 211 | 200x10 mm |
| 212 | 100x10 mm |
| 213 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : |
| 214 | 100 mm |
| 215 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 216 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement :4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Cost is inclusive of providing and laying Protection layer with 12mm thick cellotex board /12mm thick POP over polythene sheet. |
| 217 | Granite of any colour and shade Area of slab upto 0.50 sqm in flooring (As approved colour of granite ) |
| 218 | Granite of any colour and shade Area of slab above 0.50 sqm in flooring (As approved colour of granite ) |
| 219 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 220 | Granite work |
| 221 | Extra for fixing marble/ granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 222 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 223 | Polished Granite Flooring:-Providing and laying polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 224 | Polished granite stone slab of approved shade |
| 225 | Providing and laying rectified Glazed/Matt Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by approved make in colour) of 1st quality conforming to IS : 15622 of approved make in colours and shade laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand) including grouting the joints with white cement and matching pigments for 1 sqm. |
| 226 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shadecomplete. Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : |
| 227 | Red sand stone - exposed face fine dressed with roughbacking. 40 mm thick |
| 228 | Extra for carving over stone work in cladding. All complete as per design approved by Engineer-in-Charge. |
| 229 | 30 mm red sand stone sun-shade (chisel-dressed) supported on red sand stone brackets, fixed in walls with cement mortar 1:4 (1 cement :4 coarse sand), including finishing complete. |
| 230 | Providing and fixing red sand stone brackets 55x22.5x45 cm sunk and moulded including providing and fixing with 4 Nos gun metal cramp 25x6 mm 30 cm long |
| 231 | 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints finished flush. |
| 232 | Red sand stone |
| 233 | Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. |
| 234 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 235 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/ brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimumthickness at khurra as 65 mm.(Note: It is suggested that this method should be adopted after ensuring the structural safety of the structures. As per direction oe E/I.) |
| 236 | 12 mm cement plaster of mix (with fine sand): |
| 237 | 1:6 (1 cement: 6 fine sand) |
| 238 | 15 mm cement plaster on rough side of single or half brick wall of mix : (with coarse sand): |
| 239 | 1:6 (1 cement : 6 coarse sand) |
| 240 | 6 mm cement plaster of mix : |
| 241 | 1:3 (1 cement : 3 fine sand) |
| 242 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 243 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 244 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 245 | Providing and fixing of façade at all heights with extruded hollow Clay / Terracotta ventilated rainscreen tiles of height 259/ 309/ 409mm and length of 1190 mm of approved texture,design and pattern having Flexural Strength/ Modulus of Rupture of ? 14 N/m² and maximum water absorption of 10% tested as per ISO 10545-4:2004(E) and ISO 10545-3:1995 respectively in true level fixed to a supporting aluminium framework (Alloy 6063 T5/T6) consisting of vertical \"T\" (for intermediates) / \"L\" (for ends/ termination)/ Tubular sections (at corners) of size 80x60x2mm/ 40x60x2mm/ 40x40x2mm respectively, spaced at maximum spacing of 1200mm c/c matching to the tile vertical grid, and horizontal aluminium \"C\"-clamps of size 56x34x2 mm thickness of length 150mm at junction of tiles and of length 75mm at wall ends/ corners fixed on top of the vertical sections at spacing of 250/ 300/ 400mm c/c matching to the tile horizontal grid with two numbers of self-drilling / self-tapping SS screws of size 5.5x25 mm with EPDM washers. |
| 246 | The vertical \"T\"/\"L/ Tubular\" sections shall be fixed to the wall using HDG (hot-dip-galvanized) steel Lbrackets (galvanizing thickness of minimum 80 microns) of size 110x80x6 mm at intermediate vertical aluminium profiles and of size 220x110x12 mmat outer corners and stainless steel grade 304, M10 full threaded anchor fasteners with nylon sleeve 100mm long (for brick work) and M8 expansion anchor fasteners 75mm long for concrete surface, spacing of brackets to be based on a structural/ static calculation. The brackets shall be of length 175mm at junction of two vertical aluminium profiles and of length 100mm at intermediate points of vertical profiles and shall be fixed to the vertical aluminium T / L / Tubular profiles using two numbers self-drilling/ self-tapping SS screws of size 5.5x25 mm with EPDM washers.“EPDM gaskets to be fixed in between brackets and vertical profiles. The tiles shall be mounted on the ‘C’ clamps such that the tiles are supported at top and bottom at both ends. The tiles shall be mounted on the Clamps with EPDM profiles in between such that the tiles are supported at top and bottom at both ends. The vertical joint open groove between two adjacent tiles shall be 10mm. |
| 247 | The tiles and system shall be designed to resist wind load as per IS 875 (Part 3) according to different zones. The tiles shall be installed using the ventilated rain screen principle with provision for natural ventilation of the space between the façade tiles and the structural wall. The work shall be carried out as per specification, drawing and as per direction & approval of the Architect/ Engineer-in-Charge.With 24mm thickness (+/- 10%) terracotta tiles of approved size and colour |
| 248 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. |
| 249 | With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 250 | With material conforming to Grade-III (size range 26.5 mm to 0.075 mm ) having CBR Value-20 |
| 251 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 252 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 253 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 254 | ELECTRICAL WORK FOR TOILETWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 255 | Group C |
| 256 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 257 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 258 | 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire. |
| 259 | 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire |
| 260 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 261 | Supplying and fixing of brass batten / angle holder / connectors including connections etc. as required. |
| 262 | (a): Up to 450mm sweep |
| 263 | Extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes. |
| 264 | Providing and fixing extra conduit down rod of 20 mm dia, 2 X 10 cm length, wiring with 2 X 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) Remark: The item shall be executed for the suspended light points. |
| 265 | Installation, testing and commissioning of ceiling fan,including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 266 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 267 | 25 mm |
| 268 | 32 mm |
| 269 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 270 | 25 mm |
| 271 | 32 mm |
| 272 | Providing and fixing M.S. Fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. |
| 273 | Supplying and fixing following Modular base & cover plate onexisting modular metal boxes etc. as required. |
| 274 | 1 or 2 Module |
| 275 | 3 Module |
| 276 | 4 Module |
| 277 | 6 Module |
| 278 | 8 Module |
| 279 | Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. |
| 280 | 5/6 amps switch |
| 281 | 15/16 amp switch |
| 282 | 3 pin 5/6 amp socket outlet |
| 283 | Telephone socket outlet |
| 284 | TV antenna socket outlet |
| 285 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 286 | 1 run of cable |
| 287 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 288 | 6 way, Double door |
| 289 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 290 | Single pole |
| 291 | Supplying and fixing 40 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 292 | Double pole |
| 293 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 294 | 100 mm width x 50 mm depth x 1.6 mm thickness |
| 295 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 296 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 297 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 298 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 299 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Cross member” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 300 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 301 | Supply, installation, connections, testing & commissioning of 17.2 mm dia.rod of 3 meter length having copper bonding of 250 micron, along with 25 kg ofmaintenance free ground enhancing compound & shall comply as per IEEE 80:2000 Clause 14.5d with fused rod to tape clamp for interconnection of strip from earth pit to equipment. |
| 302 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 303 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 304 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 305 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor and external lighting complete as required. (For Horizontal run) |
| 306 | Supply, installation, testing and commissioning ofDown conductor holderfor GI Flat (25X3 MM) of min distance between the wall to the conductor will be of 85mm. The distance between each holder should be min of 1.5 mtr. |
| 307 | Supplying following 1.1kV grade, heavy duty XLPE insulated, FRLS type armoured /Unarmured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete as required. |
| 308 | 4C X 10 sqmm copper conductor, 2XWY |
| 309 | Supplying following 1.1kV grade, XLPE insulated, FRLS type control cables,suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation and with all components as mentioned in BOQ, specifications and schedule, complete as required. |
| 310 | 2C X 2.5 sqmm copper conductor |
| 311 | 4C X 2.5 sqmm copper conductor |
| 312 | 6C X 2.5 sqmm copper conductor |
| 313 | Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 314 | 4C X 10 sqmm copper conductor, 2XWY (25mm) |
| 315 | Surface mounted 12W LED Downlighter made of polycarobate housing, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=100lumens/watt with Minimum system Lumens 1200,Life of fixture (Including Driver) : 30000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 6500K (SDCM<5), CRI >80, PF >0.95, Min working temp range - 0°C < Ta < 45°C,an operating Voltage Range of 140 - 277 VAC.Minimum Internal Surge Protection 2.0KV & luminair manufacture shall provide LM79report from NABL accredited lab & LM80 report issued by LED manufacturer.Similar to Philips SM251C LED12S- 6500 PSU WH |
| 316 | Supply of surface LED batten TUBE LIGHT 20W made of extrusion aluminum housing, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=95lumens/watt with Minimum system Lumens 2000,Life of fixture (Including Driver) : 30000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 6500K (SDCM<=5) , CRI >80, PF >0.95, Min working temp range - 0°C < Ta < 45°C,an operating Voltage Range of 140 - 277 VAC.luminair manufacture shall provide LM79report from NABL accredited lab & LM80 report issued by LED manufacturer.Similar to Philips BN021C LED20S PSU CW GR S2 |
| 317 | 6.5W LED bulkhead made of die cast aluminum housing, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=100lumens/watt with Minimum system Lumens 700,Life of fixture (Including Driver) : 30000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 4000K (SDCM<5), CRI >80, PF >0.95, Min working temp range -0°C < Ta < 45°C,an operating Voltage Range of 140 - 270 VAC.Minimum Internal Surge Protection 2.5KV & , The fixture design should comply with EMC / EMI compliance along with BIS certification for LED Driver & Luminaire ,. luminair manufacture shall provide LM79report from NABL accredited lab & LM80 report issued by LED manufacturer.Similar to Philips WT140 |
| 318 | Supply of BEE 5star rated following ceiling fan, including wiring, the down rods of standard length (upto 30 cm) with 3x1.5 sqmm FRLS PVC insulated copper conductor single core cables etc., as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. |
| 319 | 1200 mm sweep ceiling fan |
| 320 | Supply of 300mm size exhaust fan suitable for 230V, 50 Hz AC including modifying and finishing for hole/opening for the size of fan, MS louver/ shutter complete with frame for Ex.fan including its connection with 3x1.5 sq mm FRLS copper conductor wire with PVC sleeve, loop earthing, making the good damage complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. |
| 321 | PLUMBING WORK FOR TOILETProviding and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape,size and pattern including integrated white vitreous china cistern of capacity 6 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. |
| 322 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 6 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required etc. complete in all respect as per direction of Engineering-in-charge. |
| 323 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 324 | Providing and Fixing White vitreous china Under counter wash basin with C.I. brackets painted white, 15 mm CP Brasspillar cock, 32mm dia. C.P. waste, C.P chain and rubber plug, C.P. connecting pipe to wall and C.P wall flange and rubber adapter for waste connection complete includingcutting and making goodthe wallswherever required etc. complete in all respect as per direction of Engineering-in-charge.(JAQUAR- CNS WHT-705 &(JAQUAR- CON 127 BKN) or equivalent) |
| 325 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre &post flushing with water (250 ml & 500 ml consumption), havingwater inlet from back side, including fixing to wall with suitablebrackets all as per manufacturers specification and direction ofEngineer-in-charge.(JAQUAR- WRS WHT-13261 or equivalent) |
| 326 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. |
| 327 | Granite Stone of approved shade |
| 328 | Providing and Fixing 15 mm nominal bore CP Brass long body bib cock of approved quality conforming to IS Standards etc. complete in all respect as per direction of Engineering-in-charge. |
| 329 | Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112 mm distance from wall of standard shape withbracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.) |
| 330 | Providing and fixing CP Brass Bottle Trap of approved quality & make etc. complete in all respect as per direction of Engineering-in-charge. |
| 331 | 32 mm dia |
| 332 | Providing and fixing C.P. brass angle valveof approved quality conforming to IS:8931 etc. complete in all respect as per direction of Engineering-in-charge.15mm nominal bore |
| 333 | Providing and FixingC.P. Brass Toilet paper holder,including cuttingand making good the walls wherever required etc. complete in all respect as per direction of Engineering-in-charge. |
| 334 | Providing and fixing Health faucet with 1 metre long Flexible Tube and CP wall hook with PVC & SS Screws wherever required complete as directed by the Engineer-in-charge |
| 335 | Providing & fixing grab bar (for handicapped toilet) of 600mm length. All complete as per direction of Project Incharge |
| 336 | Providing and fixing soil, waste and rain pipe: 100 mm dia |
| 337 | Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 |
| 338 | Providing and Fixing M.S. Holder bat clamp (factory manufactured) of approved design to sand cast iron / cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5 mm flat of specified shape, projecting 75 mm outside the wall surface and fixed on wall with 4 Nos, 6 mm diameter expansion hold fasteners including drilling necessary holes in brick wall /CC/RCC surface and the cost of bolts etc. . The pipes shall be fixed to the already fixed brackets with the help of 30 mmx1.60 mm galvanized M.S. flats of specified shape and total length 420 mm and shall be fixed with M.S. nuts, bolts and washers of size 25x6 mm, one bolt on each side of the pipe. |
| 339 | Total bracket length 580 mm of approved shape and design, (for single 100 mm dia pipe) |
| 340 | Total bracket length 810 mm of approved shape and design, (for single 100 mm dia pipe) |
| 341 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 mm dia |
| 342 | Hubless centrifugally cast (spun) iron epoxycoated inside & outside as per IS:15905 |
| 343 | Providing and fixing plain bend of required degree. 100 mm dia |
| 344 | Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 |
| 345 | Providing and fixing single equal plain junction of required degree : 100x100x100 mm |
| 346 | Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
| 347 | Providing and fixing double equal plain junction of required degree. 100x100x100x100 mm |
| 348 | Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 |
| 349 | Providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 100 mm |
| 350 | Sand cast iron S&S as per IS - 3989 |
| 351 | Providing and Fixing 100 mm dia Terminal guard for Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 100 mm |
| 352 | Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
| 353 | Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe 100 mm dia |
| 354 | SS 304 grade coupling with EPDM rubber gasket |
| 355 | Providing and fixing M.S. stays and clamps for sand cast iron hubless pipes of diameter: |
| 356 | 100mm |
| 357 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet |
| 358 | Hubless centrifugally cast (spun) iron epoxycoated inside & outside as per IS:15905 |
| 359 | Providing and FixingG.I. Reducing elbow (Floor drain) of 100 x 50 mm in cement concrete 1:2:4 at all levels for floor drains (excluding cost of grating) for connection to floor traps in sunken portions, complete as perdrawings and as per approval of the engineer-in-charge. |
| 360 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes including couplerconforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes. |
| 361 | 110 MM Diameter |
| 362 | Providing and Fixing to the inlet mouth of rain water pipe SS 304 grating of following diameter complete in all respects as per direction of the engineer-in-charge |
| 363 | For 100 mm dia |
| 364 | Providing and FixingG.I. \"C\" class pipe complete with G.I. Fittings and clamps, including cutting and making good the walls etc.(Internal work) |
| 365 | a)32 mm dia |
| 366 | b)50 mm dia |
| 367 | Painting of G.I. Pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. |
| 368 | a)32 mm dia |
| 369 | b)50 mm dia |
| 370 | Providing and fixing G.I. Inlet fittings with maximum 3 inlets 32,40 & 50 mm size fabricated from 100 mm dia G.I. pipes and welded G.I. sockets, fixed to C.I. Trap with joints and set in cement concrete(1:2:4)complete as directed by Engineer-in-charge. |
| 371 | Providing and Fixing SS 304 Grating with frame and SS Screws casted heavy 125 mm diacomplete as directed by Engineer-in-charge. |
| 372 | Providingand fixing castbrasscleanoutplug/ floor cleanout with suitableinsert keysfor opening,malethreaded joint withG.I.socketcaulked to spun soil pipe including cost of joint etc. completeas directed by Engineer-in-charge. |
| 373 | 100 mm dia |
| 374 | Making core cutting holes for C.I. Pipe of 100 mm dia. etc. in R.C.C. floors and roofs for passing C.I. pipe etc. and repairing the hole after insertion of C.I. pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 375 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.CONCEALED WORK, including cutting chases and making good the wall etc. |
| 376 | 15 mm nominal outer dia pipes |
| 377 | 20 mm nominal outer dia pipes |
| 378 | 25 mm nominal outer dia pipes |
| 379 | 32 mm nominal outer dia pipes |
| 380 | 40 mm nominal outer dia pipes |
| 381 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External works |
| 382 | 40 mm nominal bore |
| 383 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : |
| 384 | 40 mm dia |
| 385 | Providing and filling sand of grading zone v or coarser grade all-round the G.I. Pipe in external work |
| 386 | 40 mm dia pipe |
| 387 | Providing and fixing forged brass lever operated ball valve of full flow with forged brass ball (Machined to mirror smooth finsh with hard chrome plated) and spindle with setting and gland of superior quality having minimum working pressure of 16 kg/cm2 etc. complete in all respect. |
| 388 | 40 mm dia |
| 389 | Constructing masonry chamber 30x30x50 cm with FPS bricks, inside with brick work in cement mortar 1:4 (1 cement : 4 Coarse sand) for stop cock, with C.I. surface box 100x100x75 mm (inside) with hinged cover fixed in cement concrete slab1:2:4 mix (1 cement: 2 coarse sand : 4 gradedstone aggregate 20 mm nominal size) necessary excavationfoundation concrete 1:5:10 mix (1 cement : 5 fine sand and10 graded stone aggregate 40 mm nominal size) and insideplastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finishedwitha floating coat of neat cement complete as per standard design. With common burnt clay FPS (non modular) bricks of class designation 7.5 |
| 390 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. |
| 391 | Providing and placing two tanks on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 392 | Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5m, including getting out the excavated soil, and then returning soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplusexcavatedsoil as directed within a lead of 50 m. All Kinds of Soil Pipes, cables etc., exceeding 80mm dia but not exceeding 300mm dia |
| 393 | Providing and laying non-pressure NP2 class R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. |
| 394 | a) 150 mm Dia |
| 395 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : |
| 396 | 150 mm diameter S.W. pipe |
| 397 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design ::150 x 100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 398 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with RCC Top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix ( 1 cement :4 coarse sand: 8 graded stone aggregate 40 nominal size), inside plastering 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand),finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design .Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (Heavy duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay FPS(non modular) bricks of class designation 7.5 |
| 399 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with RCC Top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix ( 1 cement :4 coarse sand: 8 graded stone aggregate 40 nominal size), inside plastering 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand),finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design .\"Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :With common burnt clay FPS(non modular) bricks of class designation 7.5 |
| 400 | Extra depth of manholes Size 90x80cms With FPS Bricks with class designation75 |
| 401 | Providing & fixing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per I.S:10910 on 12 mm dia steel bar conforming to I.S:1786 having minimum cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 165 mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturer\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15cm cement concrete block 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size) complete as per design. |
| 402 | Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 403 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 404 | Constructing brick masonry septic tankwith 75 class designation bricks in cement mortar 1:4 (1 Cement : 4 Coarse Sand) foundation concrete 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate with 40 mm nominal size) inside and outside plastering 12 mm thickwith cement mortar 1:3 (1 Cement: 3 Coarse Sand) with water proofing compound finished with a floating coat of neat cement inside and making connection for pipe in Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) neatly finished complete as per standard design including disposal of surplus earth. |
| 405 | Cover of Septic tank to be RCC 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate with 20 mm nominal size) with a provision of 2 Nos. SFRC cover and frame (Heavy Duty) HD-20 grade designation confirming to IS: 12592, including centering, shuttering and re-inforcement all complete as per attached sketch. Internal size 3.0 m x 4.0 m x 2 m effective depth |
| 406 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 407 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 408 | ELECTRICAL WORK FOR PUBLIC CONVENIENCESWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 409 | Group C |
| 410 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 411 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 412 | 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire. |
| 413 | 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire |
| 414 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 415 | Supplying and fixing of brass batten / angle holder / connectors including connections etc. as required. |
| 416 | (a): Up to 450mm sweep |
| 417 | Extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes. |
| 418 | Providing and fixing extra conduit down rod of 20 mm dia, 2 X 10 cm length, wiring with 2 X 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) Remark: The item shall be executed for the suspended light points. |
| 419 | Installation, testing and commissioning of ceiling fan,including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 420 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 421 | 25 mm |
| 422 | 32 mm |
| 423 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 424 | 25 mm |
| 425 | 32 mm |
| 426 | Providing and fixing M.S. Fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. |
| 427 | Supplying and fixing following Modular base & cover plate onexisting modular metal boxes etc. as required. |
| 428 | 1 or 2 Module |
| 429 | 3 Module |
| 430 | 4 Module |
| 431 | 6 Module |
| 432 | 8 Module |
| 433 | Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. |
| 434 | 5/6 amps switch |
| 435 | 15/16 amp switch |
| 436 | 3 pin 5/6 amp socket outlet |
| 437 | Telephone socket outlet |
| 438 | TV antenna socket outlet |
| 439 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 440 | 1 run of cable |
| 441 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 442 | 6 way, Double door |
| 443 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 444 | Single pole |
| 445 | Supplying and fixing 40 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 446 | Double pole |
| 447 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 448 | 100 mm width x 50 mm depth x 1.6 mm thickness |
| 449 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 450 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 451 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 452 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 453 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Cross member” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 454 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 455 | Supply, installation, connections, testing & commissioning of 17.2 mm dia.rod of 3 meter length having copper bonding of 250 micron, along with 25 kg ofmaintenance free ground enhancing compound & shall comply as per IEEE 80:2000 Clause 14.5d with fused rod to tape clamp for interconnection of strip from earth pit to equipment. |
| 456 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 457 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 458 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 459 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor and external lighting complete as required. (For Horizontal run) |
| 460 | Supply, installation, testing and commissioning ofDown conductor holderfor GI Flat (25X3 MM) of min distance between the wall to the conductor will be of 85mm. The distance between each holder should be min of 1.5 mtr. |
| 461 | Supplying following 1.1kV grade, heavy duty XLPE insulated, FRLS type armoured /Unarmured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete as required. |
| 462 | 4C X 10 sqmm copper conductor, 2XWY |
| 463 | Supplying following 1.1kV grade, XLPE insulated, FRLS type control cables,suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation and with all components as mentioned in BOQ, specifications and schedule, complete as required. |
| 464 | 2C X 2.5 sqmm copper conductor |
| 465 | 4C X 2.5 sqmm copper conductor |
| 466 | 6C X 2.5 sqmm copper conductor |
| 467 | Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 468 | 4C X 10 sqmm copper conductor, 2XWY (25mm) |
| 469 | Surface mounted 12W LED Downlighter made of polycarobate housing, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=100lumens/watt with Minimum system Lumens 1200,Life of fixture (Including Driver) : 30000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 6500K (SDCM<5), CRI >80, PF >0.95, Min working temp range - 0°C < Ta < 45°C,an operating Voltage Range of 140 - 277 VAC.Minimum Internal Surge Protection 2.0KV & luminair manufacture shall provide LM79report from NABL accredited lab & LM80 report issued by LED manufacturer.Similar to Philips SM251C LED12S- 6500 PSU WH |
| 470 | Supply of surface LED batten TUBE LIGHT 20W made of extrusion aluminum housing, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=95lumens/watt with Minimum system Lumens 2000,Life of fixture (Including Driver) : 30000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 6500K (SDCM<=5) , CRI >80, PF >0.95, Min working temp range - 0°C < Ta < 45°C,an operating Voltage Range of 140 - 277 VAC.luminair manufacture shall provide LM79report from NABL accredited lab & LM80 report issued by LED manufacturer.Similar to Philips BN021C LED20S PSU CW GR S2 |
| 471 | 6.5W LED bulkhead made of die cast aluminum housing, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=100lumens/watt with Minimum system Lumens 700,Life of fixture (Including Driver) : 30000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 4000K (SDCM<5), CRI >80, PF >0.95, Min working temp range -0°C < Ta < 45°C,an operating Voltage Range of 140 - 270 VAC.Minimum Internal Surge Protection 2.5KV & , The fixture design should comply with EMC / EMI compliance along with BIS certification for LED Driver & Luminaire ,. luminair manufacture shall provide LM79report from NABL accredited lab & LM80 report issued by LED manufacturer.Similar to Philips WT140 |
| 472 | Supply of BEE 5star rated following ceiling fan, including wiring, the down rods of standard length (upto 30 cm) with 3x1.5 sqmm FRLS PVC insulated copper conductor single core cables etc., as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. |
| 473 | 1200 mm sweep ceiling fan |
| 474 | Supply of 300mm size exhaust fan suitable for 230V, 50 Hz AC including modifying and finishing for hole/opening for the size of fan, MS louver/ shutter complete with frame for Ex.fan including its connection with 3x1.5 sq mm FRLS copper conductor wire with PVC sleeve, loop earthing, making the good damage complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. |
| 475 | PLUMBING WORK FOR PUBLIC CONVENIENCESProviding and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape,size and pattern including integrated white vitreous china cistern of capacity 6 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. |
| 476 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 6 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required etc. complete in all respect as per direction of Engineering-in-charge. |
| 477 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 478 | Providing and Fixing White vitreous china Under counter wash basin with C.I. brackets painted white, 15 mm CP Brasspillar cock, 32mm dia. C.P. waste, C.P chain and rubber plug, C.P. connecting pipe to wall and C.P wall flange and rubber adapter for waste connection complete includingcutting and making goodthe wallswherever required etc. complete in all respect as per direction of Engineering-in-charge.(JAQUAR- CNS WHT-705 &(JAQUAR- CON 127 BKN) or equivalent) |
| 479 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre &post flushing with water (250 ml & 500 ml consumption), havingwater inlet from back side, including fixing to wall with suitablebrackets all as per manufacturers specification and direction ofEngineer-in-charge.(JAQUAR- WRS WHT-13261 or equivalent) |
| 480 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. |
| 481 | Granite Stone of approved shade |
| 482 | Providing and Fixing 15 mm nominal bore CP Brass long body bib cock of approved quality conforming to IS Standards etc. complete in all respect as per direction of Engineering-in-charge. |
| 483 | Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112 mm distance from wall of standard shape withbracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.) |
| 484 | Providing and fixing CP Brass Bottle Trap of approved quality & make etc. complete in all respect as per direction of Engineering-in-charge. |
| 485 | 32 mm dia |
| 486 | Providing and fixing C.P. brass angle valveof approved quality conforming to IS:8931 etc. complete in all respect as per direction of Engineering-in-charge.15mm nominal bore |
| 487 | Providing and FixingC.P. Brass Toilet paper holder,including cuttingand making good the walls wherever required etc. complete in all respect as per direction of Engineering-in-charge. |
| 488 | Providing and fixing Health faucet with 1 metre long Flexible Tube and CP wall hook with PVC & SS Screws wherever required complete as directed by the Engineer-in-charge |
| 489 | Providing & fixing grab bar (for handicapped toilet) of 600mm length. All complete as per direction of Project Incharge |
| 490 | Providing and fixing soil, waste and rain pipe: 100 mm dia |
| 491 | Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 |
| 492 | Providing and Fixing M.S. Holder bat clamp (factory manufactured) of approved design to sand cast iron / cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5 mm flat of specified shape, projecting 75 mm outside the wall surface and fixed on wall with 4 Nos, 6 mm diameter expansion hold fasteners including drilling necessary holes in brick wall /CC/RCC surface and the cost of bolts etc. . The pipes shall be fixed to the already fixed brackets with the help of 30 mmx1.60 mm galvanized M.S. flats of specified shape and total length 420 mm and shall be fixed with M.S. nuts, bolts and washers of size 25x6 mm, one bolt on each side of the pipe. |
| 493 | Total bracket length 580 mm of approved shape and design, (for single 100 mm dia pipe) |
| 494 | Total bracket length 810 mm of approved shape and design, (for single 100 mm dia pipe) |
| 495 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 mm dia |
| 496 | Hubless centrifugally cast (spun) iron epoxycoated inside & outside as per IS:15905 |
| 497 | Providing and fixing plain bend of required degree. 100 mm dia |
| 498 | Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 |
| 499 | Providing and fixing single equal plain junction of required degree : 100x100x100 mm |
| 500 | Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
| 501 | Providing and fixing double equal plain junction of required degree. 100x100x100x100 mm |
| 502 | Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 |
| 503 | Providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 100 mm |
| 504 | Sand cast iron S&S as per IS - 3989 |
| 505 | Providing and Fixing 100 mm dia Terminal guard for Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 100 mm |
| 506 | Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
| 507 | Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe 100 mm dia |
| 508 | SS 304 grade coupling with EPDM rubber gasket |
| 509 | Providing and fixing M.S. stays and clamps for sand cast iron hubless pipes of diameter: |
| 510 | 100mm |
| 511 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet |
| 512 | Hubless centrifugally cast (spun) iron epoxycoated inside & outside as per IS:15905 |
| 513 | Providing and FixingG.I. Reducing elbow (Floor drain) of 100 x 50 mm in cement concrete 1:2:4 at all levels for floor drains (excluding cost of grating) for connection to floor traps in sunken portions, complete as perdrawings and as per approval of the engineer-in-charge. |
| 514 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes including couplerconforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes. |
| 515 | 110 MM Diameter |
| 516 | Providing and Fixing to the inlet mouth of rain water pipe SS 304 grating of following diameter complete in all respects as per direction of the engineer-in-charge |
| 517 | For 100 mm dia |
| 518 | Providing and FixingG.I. \"C\" class pipe complete with G.I. Fittings and clamps, including cutting and making good the walls etc.(Internal work) |
| 519 | a)32 mm dia |
| 520 | b)50 mm dia |
| 521 | Painting of G.I. Pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. |
| 522 | a)32 mm dia |
| 523 | b)50 mm dia |
| 524 | Providing and fixing G.I. Inlet fittings with maximum 3 inlets 32,40 & 50 mm size fabricated from 100 mm dia G.I. pipes and welded G.I. sockets, fixed to C.I. Trap with joints and set in cement concrete(1:2:4)complete as directed by Engineer-in-charge. |
| 525 | Providing and Fixing SS 304 Grating with frame and SS Screws casted heavy 125 mm diacomplete as directed by Engineer-in-charge. |
| 526 | Providingand fixing castbrasscleanoutplug/ floor cleanout with suitableinsert keysfor opening,malethreaded joint withG.I.socketcaulked to spun soil pipe including cost of joint etc. completeas directed by Engineer-in-charge. |
| 527 | 100 mm dia |
| 528 | Making core cutting holes for C.I. Pipe of 100 mm dia. etc. in R.C.C. floors and roofs for passing C.I. pipe etc. and repairing the hole after insertion of C.I. pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 529 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.CONCEALED WORK, including cutting chases and making good the wall etc. |
| 530 | 15 mm nominal outer dia pipes |
| 531 | 20 mm nominal outer dia pipes |
| 532 | 25 mm nominal outer dia pipes |
| 533 | 32 mm nominal outer dia pipes |
| 534 | 40 mm nominal outer dia pipes |
| 535 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External works |
| 536 | 40 mm nominal bore |
| 537 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : |
| 538 | 40 mm dia |
| 539 | Providing and filling sand of grading zone v or coarser grade all-round the G.I. Pipe in external work |
| 540 | 40 mm dia pipe |
| 541 | Providing and fixing forged brass lever operated ball valve of full flow with forged brass ball (Machined to mirror smooth finsh with hard chrome plated) and spindle with setting and gland of superior quality having minimum working pressure of 16 kg/cm2 etc. complete in all respect. |
| 542 | 40 mm dia |
| 543 | Constructing masonry chamber 30x30x50 cm with FPS bricks, inside with brick work in cement mortar 1:4 (1 cement : 4 Coarse sand) for stop cock, with C.I. surface box 100x100x75 mm (inside) with hinged cover fixed in cement concrete slab1:2:4 mix (1 cement: 2 coarse sand : 4 gradedstone aggregate 20 mm nominal size) necessary excavationfoundation concrete 1:5:10 mix (1 cement : 5 fine sand and10 graded stone aggregate 40 mm nominal size) and insideplastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finishedwitha floating coat of neat cement complete as per standard design. With common burnt clay FPS (non modular) bricks of class designation 7.5 |
| 544 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. |
| 545 | Providing and placing two tanks on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 546 | Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5m, including getting out the excavated soil, and then returning soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplusexcavatedsoil as directed within a lead of 50 m. All Kinds of Soil Pipes, cables etc., exceeding 80mm dia but not exceeding 300mm dia |
| 547 | Providing and laying non-pressure NP2 class R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. |
| 548 | a) 150 mm Dia |
| 549 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : |
| 550 | 150 mm diameter S.W. pipe |
| 551 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design ::150 x 100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 552 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with RCC Top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix ( 1 cement :4 coarse sand: 8 graded stone aggregate 40 nominal size), inside plastering 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand),finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design .Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (Heavy duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay FPS(non modular) bricks of class designation 7.5 |
| 553 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with RCC Top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix ( 1 cement :4 coarse sand: 8 graded stone aggregate 40 nominal size), inside plastering 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand),finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design .\"Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :With common burnt clay FPS(non modular) bricks of class designation 7.5 |
| 554 | Extra depth of manholes Size 90x80cms With FPS Bricks with class designation75 |
| 555 | Providing & fixing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per I.S:10910 on 12 mm dia steel bar conforming to I.S:1786 having minimum cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 165 mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturer\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15cm cement concrete block 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size) complete as per design. |
| 556 | Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 557 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 558 | Constructing brick masonry septic tankwith 75 class designation bricks in cement mortar 1:4 (1 Cement : 4 Coarse Sand) foundation concrete 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate with 40 mm nominal size) inside and outside plastering 12 mm thickwith cement mortar 1:3 (1 Cement: 3 Coarse Sand) with water proofing compound finished with a floating coat of neat cement inside and making connection for pipe in Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) neatly finished complete as per standard design including disposal of surplus earth. |
| 559 | Cover of Septic tank to be RCC 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate with 20 mm nominal size) with a provision of 2 Nos. SFRC cover and frame (Heavy Duty) HD-20 grade designation confirming to IS: 12592, including centering, shuttering and re-inforcement all complete as per attached sketch. Internal size 3.0 m x 4.0 m x 2 m effective depth |
| 560 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 561 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |