| 1 | Attending of day to day electrical complaints pertaining to internalelectrification received through telephone or in person or online on detailment at MES Service centre located at NAMS Areaby locating and rectification of fault from and including electric meter/DB onwards in respect of sub main/point wiring including provisioning of small pieces of electric cable of size 1.5/2.5 Sqmm to 10 Sqmm single core copper conductor and length not increasing 0.50 mtrs and carrying out repairs to the extent of tightening of loose connections, disconnection anddismantling of faulty wires, battens, conduits, boxes including providing necessary screws / nuts / bolts / nailsfor the rectification of defect and refixing of existing dismantled serviceable items complete all as specified and directed. Note - (i) If complaint warrants replacement of material as catered in BOQ here-in-after shall be paid under relevent item and no measurement shall be done under this item. Rate of attending complaint shall be considered to be quoted in the respective item. (ii) Complaint pertaining to location and rectification of fault in more than one length of point wiring/sub main wiring/DB\"s/ fitting or fixtures etc shall be considered as an independent complaint. Similarly complaint pertaining to replacement oftwo fixtures in one Qtr will also be measured and paid as one complaint. |
| 2 | (iii) In case a Qtr/room is found locked when tradesman is detailed to attend the complaint, the complaint shall be treated as one till its completion.(iv) Necessary tools for tradesman shall be provided by the contractor.(v) Transportation for tradesman and normal stores required for complaints shall be arranged by the contractor.(vi) Complaints of normal nature shall be attended and rectified within 8Hrs of receipt of complaint. However, complaints of emergent naturei.e no light, short circuit, earth fault etc shall be attended immediately onreceipt of complaint round the clock. (vii) Bldgs requiring rewiring of small qty of point wiring if ordered will be measured and paid separately under respective items below. (viii) Conttractor or his rep will report to AGE EM complaint cell at 9 O\"Clock daily for collecting of complaints. Complaint received will be done in the same day and after completion of complaint he will report to complaint cell to submit the complaint slip duly signed by the user.done on Holidays/ Sunday. (ix) For Non attending of complaint within above mentioned time a penalty of Rs 50.00/per day/per complaint will be levied on contractor.This penality shall also be applicable to all the items mentioned in BOQ here-in-after. |
| 3 | Supply and fixing in replacement switch piano flush type 5 AmpsOne-way, AC 230V on existing switch board all as specified and as directed. |
| 4 | Supply and fixing in replacement of switch piano flush type15 Amps single pole one-way,230V complete all as specified and as directed. |
| 5 | Supply and fixing in replacementswitch piano type two ways AC 230 volts6 Ampsas per on existing switch board . |
| 6 | Supply and fixingin replacement socket out let 2-in-1,3 Pin 6 Amps flush type 230 volts complete all as specified and as directed. |
| 7 | Supply and fixingin replacement socket outlet, flush type, 2-in-1, 3 pins, 6 & 16 Amps multipurpose complete all as specified and as directed. |
| 8 | Supply and fixing in replacementbell push switch piano, flush type, 5 Amps complete all as specified and as directed. |
| 9 | Supply and fixing in replacement of bell ding-dong230 volts, single phase complete all as specified and as directed. |
| 10 | Supply and fixing in replacement of ceiling rose 65x50mm two to three terminals AC 230 volts complete all as specified and directed of any make/model as per in existing building. |
| 11 | Supply and fixing in replacementbatten type angular/ Batten lamp holder insulated body with back plate suitable for batten fitting including PVC round block complete all as specifed and as directed. |
| 12 | Supply and fixingin replacement MCBs single pole (SP) 6 to 32 Amps with 10 KA breaking capacity of \"B\" series in distribution boards all as specified. |
| 13 | Supply and fixing in replacementMCBs single pole and neutral (SPN) 32 Amps with 10 KA breaking capacity of \"C\" series in distribution boards all as specified and directed. |
| 14 | Supply and fixing in replacementMCBs single pole (SP) 40 Amps with 10 KA breaking capacity of \"B\" series in distribution boards all as specified and directed. |
| 15 | Supply and fixing in replacementMCBs single pole and neutral (SPN) 40 to 63 Amps with 10 KA breaking capacity of \"C\" series in distribution boards all as specified and directed. |
| 16 | Supply and fixing in replacement of single pole and neutral sheet metal enclosures with two pin & earth plug and socket complete with one single pole MCB of 20 Amps complete all as specified and as directed. |
| 17 | Supply and fixingin replacement plug top 3 pin, 5 Ampscomplete all as specified and as directed. |
| 18 | Supply and fixingin replacement plug top 3 pin, 15 Ampscomplete all as specified and as directed. |
| 19 | Supply and fixingin replacement LED Tube rod with polycarbonate diffuser 4 feet long of capacity 18 watts complete with all accessories all as specified & directed by Engr-in-Charge. |
| 20 | Supply and fixingin replacement LED Tube rod with polycarbonate diffuser 4 feet long of capacity 20 watts complete with all accessoriesall as specified & directed by Engr-in-Charge. |
| 21 | Supply and fixingin replacement LED Tube rod LED tube rod with polycarbonate diffuser 4 feet long of capacity 22 watts complete with all accessoriesall as specified & directed by Engr-in-Charge. |
| 22 | Supply and fixing in replacement ofLED 12 WattSquare/round shapesurface mounted LED Paneldown light of size as per site requirementcomplete all as specified and directed, |
| 23 | Supply and fixing in replacementLEDbulk head light fittings including led lamp 10 wattas per IP65 and making necessary connections complete all as specified |
| 24 | Supply and fixingin replacement LED slim panel recess/surface/suspended mounting LED slim ceiling light 2\"x2\" with extruded aluminium housing and milky diffuser, suitable for recess mounted size 595x595mm complete with LED tube. |
| 25 | Supply and fixing in replacement of6 WattRound/square recess mounteddown lightseparate replaceable electronic driver celling cut out dia as per existing shaped polycarbonate fixturecomplete all as specified and directed, |
| 26 | Supply and fixing in replacement of 15 WattSquare/round recess mounteddown light separate replaceable electronic driver celling cut out as per existingsquare shaped polycarbonate fixturecomplete all as specified and directed, |
| 27 | Supply and fixing in replacement of18 watt Square recess mounteddown light separate replaceable electronic driver celling cut out dia as per exising size/round or square shaped polycarbonate fixturecomplete all as specified and directed, |
| 28 | Supply and fixing in replacemntbox type PVC rectangular block for mounting switches, sockets, fan regulator of size 175 x 100 x 50 mm surface mounting including necessary gitti for fixingcomplete all as specified and as directed. |
| 29 | Supply and fixing in replacement of frame plate with cover for modular switch 3/4 module includingscrews and washers etc model/make as per existingin site complete all as specified and as directed. |
| 30 | Supply and fixing in replacement of frame plate with coverfor modular switch 6/8 module includingscrews and washers etc model/make as per existingin site complete all as specified and as directed. |
| 31 | Supply and fixing in replacementceiling fan regulator, electronicSocket type, single phase, 230 volts complete all as specified and as directed. |
| 32 | Supply and fixing in replacementceiling fan regulator, electronicswitch type, single phase, 230 volts complete all as specified and as directed. |
| 33 | Supply and fixing in replacement MS machine screw 25 mm longsuitable forfixingbakelitehylam sheets / square blocks complete all as specified and directed . |
| 34 | Supply and fixingin replacementMS Housing box for PT Switch as per site requirment as per existing including taking out old UNSVswitch boxand making good to the disturb surfaceby pcccomplete all as specified and as directed. |
| 35 | Supply and fixing in replacement ofMCCB 100 amps 4 pole, AC 415 volts 16 KA, including making connections with suitable size of aluminium lugs of any make /Model as per Existing MCCB Fitted in DB. all as specified. |
| 36 | Supply and fixing in replacement of modular switch6 Amps one module230 volts AC as per existing model/make complete all as specified and as directed |
| 37 | Supply and fixing in replacement of modular switch16 Amps one module230 volts AC as per existing model/make complete all as specified and as directed |
| 38 | Supply and fixing in replacement of modular socket, 5/6A -2/3 pin combined 2 module,230 volts AC as per existing model/make complete all as specified and as directed. |
| 39 | Supply and fixing in replacement of modular socket, 15/16A -2/3 pin combined 2 module,230 volts AC as per existing model/make complete all as specified and as directed . |
| 40 | Supply and fixing in replacement of modular fan regulator 120 W , 2 Module ,230 volts AC as per existing model/make complete all as specified and as directed . |
| 41 | Supply and fixing inreplacement of capacitor AC 230 volts 2.25 microfarads complete all as specified and as directed, |
| 42 | Supply and fixing inreplacement of capacitor AC 230 volts 3.15 microfarads complete all as specified and as directed. |
| 43 | Supply and fixing in replacement of 3 mm thick hylam sheet of any sizeincludingscrews and washers etc as per required at site complete all as specified and as directed. |
| 44 | Supply and fixing in replacementmoduler bell push switch piano, flush type, 6 Amps complete all as specified and as directed. |
| 45 | Supply and fixing in replacement LEDtube light fitting. ,1 x 20 W, 230 V Energy efficient T8, Box type made of CRCA shee heavy duty industrial type housing with reflector cover channel, bipin holders, connector block, etc. complete with tube rod LED 18/20 watt, all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. |
| 46 | Supply and fixing in replacementBatten Series, LED luminaire using LEDs 20 watt with \"Eye Soft\" technology & glarefree diffuser for perfect application , Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets complete all as specified and as directed. |
| 47 | Supply and fixingin repacement PVC round fan cover plate of size 6\" to 8\" or as per exiting size complete all as specified and directed. |
| 48 | Supply and fixing in repacement casing caping of existing size as per site including laying of electric wire inside, making electric connection and fixing necessary saddle and gitti at regular interval complete all as specified and directed. |
| 49 | Supply and fixing in replacement LEDmirror fitting.1 x 8/9 W, 230 V Energy efficient , Batten type, polycarbonate housing with reflector cover channel,all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. |
| 50 | Supply and fixing in replacementof single corewire 2.5 Sqmm multi-strand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed. |
| 51 | Supply and fixing in replacementof single corewire 1.5 Sqmm multi-strand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed. |
| 52 | Material and labour for point wiring with 1.5 Sqmm multi strand pvc insulated copper conductor cable in existing concealed conduit for one light or bell point controlled by one switch including pvc insulated 1.5sqmm copper conductor continuousearth wire using existing CI/MS sunken box and connecting earth with dolly complete all as specified and directed. ( Note : Switch, socket measured as separate item ) |
| 53 | All as per item No 51 here in before but for one5 Amps independent board complete |
| 54 | All as per srl item No. 51 here in before but for one5 ampssocket out but on the same board complete |
| 55 | Matrial and labour for point wiring with2.5 sqmm multi strand pvc insulated copper conductor cable in existingconcealed conduit for one 15 amps socket outlet independentcontrolled by one switch including pvc insulated 2.5 sqmm copper conductor continuousearth wire connecting earth with dolly complete all as specified and directed. |
| 56 | Supply & fix in replacement of building security LED Light Luminaire 25 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240,50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lenscomplete all as specified. |
| 57 | Supply and fix in repair GI pipe bracket ,made out of GI pipe 50mm dia light grade 1.2mtr long bend to the shape 120 degrees anglecomplete with two nos of clamps for fixing on walls complete all as specified and directed. |
| 58 | Supply and fixing in replacement Garden light/post top lantern with provision of LED bulb holder type230volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and 9 W LED lamp complete all as specifed and as directed. |
| 59 | M& labour in replacelment for service wire10 sqmm 2 core pvc insulated and pvc sheathested 1100 volts grade all as specified and directed |
| 60 | M & L for taking down the existing faulty single phase temper proof eletronic energy meter wih LCD display 230 volts 4 wire system , 10-60 amps , 50Hz , replacing the required unserviceable parts and making it to serviceable state, including testing, caliberation & refixing the same complete all as specified and directed by Engr-in-charge. |
| 61 | M & L for taking down the existing faulty three phase temper proof eletronic energy meter wih LCD display 230 volts 4 wire system , 10-60 amps , 50Hz , replacing the required unserviceable parts and making it to serviceable state, including testing, caliberation & refixing the same complete all as specified and directed by Engr-in-charge. |
| 62 | Supply and fixing in replacement of automatic monoblock pressure/booster pump size 25 mm x25 mm, tech motor S1 class B 230 Volts 50 Hz, RPM 2800, 10 MF, Input power 650 watt with pressure tank of cap 19 Ltrs PS max pressure bar 10 PT test pressure bar 14 with complete accessories incl GI pipe/gate valve/NRV complete all as specified and directed. |
| 63 | M&L for earthing completewith galvanisedsteelearth plateelectrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade)and watering pipe 20 mm bore GI pipe(light grade ) andchamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg.50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PART 1 , with charcoal dust and saltcomplete and earth leadconnected to earthing test point (up to main switche, DBs) completeall as specified &testing on completion. |
| 64 | Supply and Laying in replacement in trenches or passing through pipe or fixing to pole/wall UG cable XLPE, of cross section area25 sqmm 4 core, PVC insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade. Note :(I)Earth work/ sand cushioning shall be measured and paid separately . |
| 65 | Excavation in trenches in soft/loose soil n.exc. 1.5mtr wide and n. exc. 1.5mtr in depth and getting out for laying of cablesall as specified and directed |
| 66 | Removing excavated material n. exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed. |
| 67 | Returning, filling in, and including spreading, levelling,watering and well ramming in layers not exceeding 25 cm thick complete all as specified. |
| 68 | Supply,laying & fixing in replacement double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps etc.. allas specified and directed by Engr in Charge ofsize 63 mm outer dia and 50 mm inner dia. |
| 69 | Drilling hole under the road with the help of drilling machine without damaging the road horizonally for rod crossingfor cable protection complete all as sp an directed. |