| 1 | Total amount of Sch \"A\" Part-IBuilding WorksNote :- This schedule is not pre-priced by MES and the rate indicated as \"Rs. 0.00\" under column 6 signifies this fact only. |
| 2 | Soil investigation, Design, Fabrication and Construction of 06XOR SINGLE LIVING ACCN IN 402 LT AD REGT COMP AT BHALUKMARAin RCC Framed Structure as per Arch Drg No. CWE/DIN/13/24 sheet No. 1/3 to 3/3and CWE/DIN/06/24 sht 1/1 dated 23.12.2024and specification given in Sch A Notes and Particular Specifications including complete RCC foundation and plinth, Flooring, Joinery and Finishes complete all as specified.NOTE: Soil investigation will be measured and paid separately.(i) Size – As per Arch drawing(ii) Height – 320 CM(iii) Fdn – To be design as per SBC report with RCC framed construction.(iv) Plinth – Burnt Brick wk in CM 1:6(v) DPC – 40 mm thick PCC 1:2:4 with WPC(vi) Super Structure – All RCC structure to be M25 design mix burnt brick wk wall upto ceiling.(vii) Seismic Zone – Strengthening measures for Zone V(viii) Roof – RCC flat roof in M25 design mix & roof treatment with APP membrane.(ix) Internal Plaster – Internal 15 mm thick in CM (1:6)(x) Flooring – Non skid ceramic tiles in toilet and bathroom over 15mm thick sreed bed in base of CM 1:6 over a layer of PCC 1:2:4 over sub base of PCC 1:5:10.(xi) Dado/Skirting – Glazed ceramic tails over 10 mm thick cement screed in CM (1:3) up to lintel height.(xii) Joinery – Frames – pressed steel, shutter – Factory made flush door shutter (TD Drg No CESZ/2015/TD/03 Sheet 1/2 & 2/2)(xiii) Joinery Window – Steel Window with Guard bars/grill (TD Drg No CESZ/2015/TD/19 Sheet No 1R/3, 2R/3 & 3R/3)(xiv) Steel Guard – MS Guard bars to window(xv) Iron monger – Prefabricated aluminum anodized fittings. (TD Drg No CESZ/2015/TD/03 Sheet 1/2 & 2/2)(xvi) Plinth Protection – 75 mm thick PCC 1:3:6 over stone hard core.(xvii) Painting – Synthetic enamel paint on steel/wooden surface.(xviii) Finishes – Internal 02 coats of oil emulsion distemper incl 1mm thick wall care putty over a coat of primer. External - Cement base paint over a coat of primer.(xix) Sanatory Fitting – Vitreous China IWC, WHB ect of approved make including plumbing work (TD Drg No CESZ/TD-38 Sheet No 1/2& 2/2 andTD Drg No CESZ/TD-31 Sheet No 1/2& 2/2).(xx) Antitermite treatment - As per IS-6313 Part-II : 2001 (xxi) Mosquito Proofing – All external Door and window. |
| 3 | NOTE: Schedule ‘A’ Part IItoVIIare Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-13 only. |
| 4 | Total amount of Sch ‘A’ Part II (Excavation, Earthwork & Site Clearance) |
| 5 | Total amount of Sch ‘A’ Part III (Internal Electrification) |
| 6 | Total amount of Sch ‘A’ Part IV (Internal Water Supply) |
| 7 | Total amount of Sch ‘A’ Part V (External Electrification) |
| 8 | Total amount of Sch ‘A’ Part VI (External Water Supply) |
| 9 | Total amount of Sch ‘A’ Part VII (Sewage Disposal) |
| 10 | SCH \"A PART VIII(Miscellaneous B/R and E/M works)Note: This schedule is not pre-priced by MES and the rate indicated as \"Rs 0.00\" under Col 6 signifies this fact only |
| 11 | M & L for boring 100 mm dia hole in all kind of soil upto maximum depth 10 meter or up to refuse (N=100) whichever meet earlier including collection of undisturbed sample from cohesive soil only conducting standard penitration test at 12 meter and 1.5 meter interval alternatively as per relevant IS code complete all as directed. |
| 12 | Conducting necessary lab test on selected soil sample (obtained from item here in before) as per relevent nature moisture content, bulk and dry density sleve and hydrometer analysis, liquid and plastic limit, SP gravity unconfined compressive test (UU) or direct consolidation test etc complete all as relevant IS codes or all as specified and directed. |
| 13 | Completion of field work & lab test result and submission of report in Per Job quadruplicate suggesting depth of foundation type of fundation and safe bearing capacity with CD-1 (one) copy complete all as specified and directed. |
| 14 | Supply and fixingLED tube light fitting 1 x 20W, 220V,AC with extruded strip in thermally conductive material & extruded housing in optically efficient material milky white with system lumen efficacy > 120 lumen per watt minimum system 2300 –2400 and make of LED Chip : Osram, Cree ,Nichia, Seoul , Samsung . Integrated electronic driver , SMD based LED constant current supply with double sided connection to avoid short circuit and surge protection greater than 2.5 KV , IP 20 protection and CRI>80, Power factor> 0.95, THD less than 15%, correlated Colour temperature (CCT) of 6500K, Operating Voltage of 140 V to 270 V , frequency of 50Hz , burning hours 50000 hours with comprises of CRCA pre coated metal housing complete all as specified and directed. |
| 15 | Supply and fixingLED tube light fitting 1 x 10W, 220V,AC with extruded strip in thermally conductive material & extruded housing in optically efficient material milky white with system lumen efficacy > 120 lumen per watt minimum system 2300 –2400 and make of LED Chip : Osram, Cree ,Nichia, Seoul , Samsung . Integrated electronic driver , SMD based LED constant current supply with double sided connection to avoid short circuit and surge protection greater than 2.5 KV , IP 20 protection and CRI>80, Power factor> 0.95, THD less than 15%, correlated Colour temperature (CCT) of 6500K, Operating Voltage of 140 V to 270 V , frequency of 50Hz , burning hours 50000 hours with comprises of CRCA pre coated metal housing complete all as specified and directed. |
| 16 | S&F street light bracket fabricated out of GI Tubing light grade 40 mm bore Bend to the shape as directed and of length 1.5 mtr complete with mounting MS clamp of flat iron size 40 X 5mm of suitable length 02 pairs incl nut bolts etc of suitable size, including all as specified and directed. |
| 17 | Supply & fixing Gun metal non return valve 15 mm dia (ISI Marked) for fixing in inlet connection pipe all as specified and directed. |
| 18 | Design, fabricate ,supply ,testing and commisioning of LT feeder pillar box out door typeof size 1100X1100X 600 mmfabricated with 3.15mm thick CRCA sheet steel front and rear openable vertical cubical type installed over properly supported legs suitablily grouted to PCCwith copper bus bar, phase indicator lamps & internal wiring including the following accessories. (Toilet panel ) :-(a) INCOMING(i) MCCB 100A 4 Pole 415 V 36 KA-01 No.(b) OUTGOING(i) MCCB 63A 4 Pole 415 V 25 KA -02 Nos(ii) MCB DP 6-32 Amps, 240 V, \"C\" curve, 10 kA -01 Nos(iii) Digital Multifunction meter with 3 Nos CTs & selector switch - 1set (iv) Space for One MCCB 4 Pole upto 63 Amps |
| 19 | Construction of measonary valve pit chamber with burnt brick (Sub class \"B\") in cementmortor (1:6) and 10 mm thick plastering in CM 1:4 and PCC (1:4:8) type D-2 in foundation bed or size internally climent on (600 x 600 x 600) mm size with 3 mm thick MS sheet cover with locking arrangement hinged with (40 x 40 x 5) mm angle iron frame embeded in PCC (1:3:6) type C-1 etc including painting with two coats of synthetic enamel paint over a coat of red oxide primer to all steel surfacescompleted including earth work all as specified and directed. |
| 20 | M & L for point wiring with 1.5 sqmm (Nominal Area) FRLS PVC insulated un sheathed multi stranded copper conductor, 1100 Volts grade, in and including PVC casing capping/conduit(ISI marked) with accessories such as bends, cross, elbow, tees etc. of suitable sizeincluding MS pressed steel cadmium plated terminal box not less than 1.6 mm thick for mounting switches, sockets, fan regulators etc and 3 mm thick laminated sheet top cover(ISI marked) including continuous earth wire FRLS PVC insulated unsheathed 1.5 Sq mm(nominal area) copper multistarnded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified for one light point/Exhaust fan/ceiling fan/ call bell point pointcontrolled by one switch Note : Wiring Color code i.e. Red/Yellow/Bluefor Phase, Black for neutral and Green for earth shall be maintained. |
| 21 | S & F Switch piano flush type single pole one way 5A SP 230 Volts. |
| 22 | S & FCeiling rose surface type 3 terminals 65x20mm compelete all as specified and directed |
| 23 | M & L for point wiring with 2.5 sqmm (Nominal Area) FRLSPVC insulated un sheathed multi stranded copper conductor, 1100 Volts gradefor 3 Pin socket outlet 15Amps on independent board with PVC conduit (ISI Marked) medium duty not less than 20mm diawith accessories such as elbow, tees,internal & external bend etc. of suitable size including continuous earth wire FRLSPVC insulated 1.5 Sq mm copper multi stranded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified. Note : 1) Wiring Color code i.e. Red for Phase, Black for neutral and Green for earth shall be maintained. 2) Necessary chase cutting for conduits if requires, shall be measured & paid separately under respective items in this schedule. |
| 24 | S&F Switch Socket combination outlet 2 in 1 3/5 pin 5 and 15 Amps flush type complete all as specified and as directed. |
| 25 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring,etc., and making good, cutting not exc 10 cm girth complete all as specified and as directed. |
| 26 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 27 | Supply and Installation of Solar waterheating system ,Flat plate collector type,with heat exchanger of 500 litre per day capacity ,with electrical heating back up complete all as specified and as directed. |
| 28 | Supply and fix MCB SP 240V, 6-32 Amps capacity complete all as specified and as directed. |
| 29 | Supply and fix MCB SPN 240V, 6-32 amps capacity complete all as specified and as directed. |
| 30 | M&L for Cutting existing steel tubing of size 20-25 mm dia for alterations or additions (incl all fittings) complete all as specified and as directed. |
| 31 | Supply and laying 20mm dia GI pipe galvanized Medium grade including fittings for ceiling mounted complete all as speicified and directed. |
| 32 | S&F chromium plated Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 33 | S&F for gun metal gate valve with iron wheel head ,screwed each down iron pipe of 20 mm bore complete all as specified and as directed. |
| 34 | S&F sheet metal enclosure of Bus bar of 4 way with 200 amps rated bus double door bar complete all as specified and as directed. |
| 35 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed. |
| 36 | Supply & laying bricks (sub class-\"B\") laid in trenches as cable protection with width equal to the length of bricks complete all as specified and as directed. |
| 37 | M&L for Sand cushioning for underground cable protection complete all as specified and as directed.(using silver sand consolidated thickness after tampering shall be measured & paid ) complete all as specified and as directed. |
| 38 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor 16 sq mm 4 core complete all as specified and as directed. |