| 1 | Supply and making end termination with brass compression gland and aluminium lugs for 3.5C X 240 sq. mm (62mm) size of XLPE insulated and PVC sheathed aluminium conductor cable of 1.1 KV grade as required. |
| 2 | Supply and making end termination with brass compression gland and aluminium lugs for 3.5C X 50 sq. mm (35mm) size of XLPE insulated and PVC sheathed aluminium conductor cable of 1.1 KV grade as required. |
| 3 | Supplying of one number 3.5C x 240 Sq.mm size Aluminium conductor XLPE insulated PVC sheathed power cable of 1.1 kV grade etc. as required. |
| 4 | Supplying of one number 3.5C x 50 Sq.mm size Aluminium conductor XLPE insulated PVC sheathed power cable of 1.1 kV grade etc. as required. |
| 5 | Supplying and laying of 90 mm dia (OD-90 mm & ID-76 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 6 | Supplying and laying of 120 mm dia (00-120 mm & ID-103 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 7 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Above 35 sq. mm and upto 95 sq. mmdirect in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 8 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Above 185 sq. mm and upto 400 sq. mm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 9 | Supply and layingof 5 inch 125 NB GI pipe (medium class B)on ground with all accessories like socket, bend, couplerswith fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., and making good the damages of road with concrete mixture of 1 : 2 : 4 including watering & ramming etc. as required. |
| 10 | Supplying and making cable route marker with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) of size 30 cm X 30 cm at the bottom and 25 cm X 25 cm at the top with a thickness of 10cm including inscription duly engraved and painting as required. |
| 11 | Fabrication and Design ofthe following dust and vermin proof outdoor typefree floor/wall mounting panel boards confirming to IS and IE rules made out of 14SWG GP/GI sheet and necessary MS angles or flats duly powder coated with approved colours, hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets removable gland plates as per specifications and interconnected with suitable Cu Busbar consisting of panel mounting type switch gears with all rigid connections and control wiringsIncoming(Appropriate make) -DN2 250D 250A 36KA 4P MCCB Microprocessor type - 1 No 4P SPREADER-1NoEX.ROM-1NoOutgoing (Appropriate make)DU 250C 25KA 200A 4P MCCB-1No4P SPREADER-1NoEX.ROM-1NoDN0 100 CC 25KA 100A 4P MCCB-3 Nos4P SPREADER-3 SetEX.ROM-3 NosRYB indicators-1SetToggle Switch - 3Nos with control wiringBus Bar:- 25 x 10 mm & 25 x 6 mm mm CU Busbar with heat shrinkable PVC sleeve colour coded and supported by epoxy supports-1No |
| 12 | Fabrication and Design ofthe following dust,weather and vermin proof outdoor type floor mounted 3 phase energy meter box panel confirming to IS and IE rules made out of 14SWG GP/GI sheet and duly powder coated with provisionsfor fixing energy meter and CTs along with proper connectors and cable end terminations. |
| 13 | Supply Installation Testing and Commissioning of 3 phase 4 wire 240V (L-N) 10 - 60A electronic type CT operated energy meter with LCD display class 0.5s base mounting type with hinged boxincluding connections etc. as required. |
| 14 | Supply Installation Testing and Commissioning of 100/5A CT suitable in outdoor type box,including connections etc. as required. |
| 15 | Supplying and fixing cable details tags using Aluminium sheet ofsize 10 cm X 3 cm X 2 mm or nearest size on the existing cable. |
| 16 | Markings on existing panel boards using paint (incoming, outgoing, cable size, switchgear rating etc) as required/ instruction from Engineer in charge. |
| 17 | Providing and fixing 25 mm X 3 mm G.I strip on surface or in recess for connections etc. as required. |
| 18 | Providing and fixing 25 mm X 6 mm G.Istrip on surface or in recess for connections etc. as required. |
| 19 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement, watering pipe of 2.7 metre long etc.with charcoal/coke and salt as required. |
| 20 | Supply of suitable amount (60kg) of earthing compound (EXCEL compound or equivalent) etc. as required. |
| 21 | Supply and laying one number of the 8 SWG good quality bare copper wire along the cable with connections etc. as required. |
| 22 | Supply of appropriate safety charts and posters with appropriate instructions and guidelinesfor the implementation/ fixing at Work site, substations and STP units. |