Tender For Provision Of Otm Accommodation For Lltr At Af Stn Purnea; 1 SCHEDULE A Part - I (BUILDINGS/STRUCTURES WORK)Details of Buildings are given here-in-before:- 2 SCHEDULE A PART- II ( SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK) Details of prepriced Schedule is given in tender documents 3 SCHEDULE A PART- III( INTERNAL ELECTRIFICATION)Details of prepriced Schedule is given in tender documents. 4 SCHEDULE A PART-IV ( INTERNAL WATER SUPPLY )Details of prepriced Schedule is given in tender documents. 5 SCHEDULE A PART- V (ROAD/PATH&CULVERT)Details of prepriced Schedule is given in tender documents. 6 SCHEDULE A PART- VI (AREA DRAINAGE)Details of prepriced Schedule is given in tender documents 7 SCHEDULE A PART- VII (SEWAGE DISPOSAL)Details of prepriced Schedule is given in tender documents 8 SCHEDULE A PART- VIII (EXTERNAL WATER SUPPLY)Details of prepriced Schedule is given in tender documents 9 SCHEDULE A PART- IX(EXTERNAL ELECTRIC SUPPLY)Details of prepriced Schedule is given in tender documents. 10 SCHEDULE A PART- X (FENCING AND GATE)Details of prepriced Schedule is given in tender documents 11 SCHEDULE A PART- XI(AIR CONDITIONER)Details of prepriced Schedule is given in tender documents. 12 SCHEDULE A PART -XII (MISCELLANEOUS ITEMS)Note:- This scheduleis not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under Col. F signifies this fact only. 13 ( SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK)Supply only approved earth soil for construction of soil sub grade and shoulders approved material obtained from borrow areas outside MOD land by the contractor at his own cost, with all lifts & leads, transporting to site, soil tested as per IS: 2720, shall have Maximum laboratory dry unit weight not less than 17.5 KN/Cum and depositing where directed all as specified & directed by Engr-in-Charge. (Note :-The soil recovered/excavated shall be tested in the presence of GE/ Engr-in-Chargein any Govt. approved lab and will be incorporated for preparation of subgrade etc., if found the soil suitable after testing.) 14 INTERNAL ELECTRIC SUPPLYS&F MCB 230 V, 50 Hz, Single Pole, 63 Amps 10KA C curve complete all as specified and as directed.. 15 SEWAGE DISPOSALM&L for RCC Septic tank conventional type for 100 users,designed to carry sewage and sullage water, excavation in any type of soil, PCC (1:3:6) type C2 below foundation, RCC M-25 (Design Mix) in walls, Base slab, Baffle walls and Roof Slab including beams etc with vent shaft, manhole openings with cover connection etc, complete all as per DRG NO AF/STD/STRU/265 SHEET NO 1/2 & 2/2, DT 24/04/2023. 16 M&L for Soakage wells for 100 users, excavation, in any type of soil, foundation in PCC (1:3:6) type C2,walls of honey combed masonry with top ring of RCC M25 (Design Mix) concreete indluding intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size not less than 3M dia x 4.5M effective depth etc, complete all as per DRG NO AF/TD/STRU/236 SHEET NO 1/2 & 2/2 DT 19/08/2014. 17 EXTERNAL WATER SUPPLYConstruction of brick masonry valve pit of size 90cm x 90cm x 90cm (internal dimensions) with one brick thick wall in cement mortar (1:4) on 100 mm thick P.C.C. (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in foundation lean concrete, including PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in bedding and coping and 10mm thick cement plaster in CM (1:4) internally and externally up to 15cm below ground level including three coats of white wash on plastered surface providing valve pit 25 x 25 x 5mm MS angle iron frame all-round the fixed point by means of 4Nos holdfast 150mm long made out of flat iron 25 x 6mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stoned aggregate) of size 230 x 200 x 100mm including provision of hinges welded with angle iron frame and MS cover 3mm thick, MS handle of suitable and size welded with MS cover and suitable locking arrangement including 65mm diapad lock and applying two coats of synthetic enamel paint over a coat of red oxide primerincluding necessary excavation and earth work, removing/returning filling in, any type of soil complete all as specified and directed. 18 EXTERNAL ELECTRIC SUPPLYSupply, install, commissioning and testing factory madefloor mounted outdoor cubical type LT panel board of size 1.0m (height) x 1.5m (width) x 0.5m (depth), made out of 3.15mm thick CRCASheet and angle iron 50x50x6 mm frame facory made CPRI approved totally enclosed dust and vermin proof both side hinged opening arrangment on front and back with locking araggement cable entry and exist from bottom with cable glands and gaskets, aluminium bus bar of suitable rated fixed on porcelain insulator with internal wiring with suitable size of aluminium strips to be used for incoming and outgoing connections of all MCCBs & Bus-bar shall be insulated with colour code sleeves/ tapes and to be connected withAluminium lugs, including two coats of synthetic enameled paint on the surface externally & internally over a coat of red oxide primer paint incl necessary PCC (1:3:6 ) typeC2 in foundation all as directed ,comprisioning of the following:-.(Panel-1)Incoming:-(a) 400 Amps MCCB, 415 Volts 4 pole, 36 KA - 01 No(b) Digital type Ampere meter 0-500 Amps with Cts & selecter switch - 01 Set(c) Digital type Volt meter 0-500 Volts with PTs & selecter switch - 01 Set (d) LED Indicating lamps for main supply indicating R, Y, B - 01 Set(Set of 3)(e) Aluminium Bas Bar rating 800 Amps - 01 Set of 04 19 Serial Item No. 18 (Contd....)Outgoing:-(a) MCCB 250 Amps, 415 Volts 4 pole, 25 KA - 01 No (For RADAR). (b) MCCB 160 Amps, 415 Volts 4 pole, 25 KA - 01 No (For OTM Accn).(c) MCCB 100 Amps, 415 Volts 4 pole, 16 KA - 02 No (For Spares). 20 Supply and fix 19 cm dia cable route indicator made of CI plate 8 mm thick with spike to angle iron 25x25x5mm, 40 cm long marked as LT cable jointing on conductor coil plate complete including excavation in soft/loose soil or hard/dense soil, embeded in PCC (1:3:6) block of size 300x300x300 mm, type C1, using 20mm graded crushed stone aggregate etc complete all as specified and directed. (Note: Excavation & earth work and PCC block shall deemed to be included in the unit quoted rate.) 21 Supply, install, commissioning and testing factory madefloor mounted outdoor cubical type LT panel board of size 1.0m (height) x 1.5m (width) x 0.5m (depth), made out of 3.15mm thick CRCASheet and angle iron 50x50x6 mm frame facory made CPRI approved totally enclosed dust and vermin proof both side hinged opening arrangment on front and back with locking araggement cable entry and exist from bottom with cable glands and gaskets, aluminium bus bar of suitable rated fixed on porcelain insulator with internal wiring with suitable size of aluminium strips to be used for incoming and outgoing connections of all MCCBs & Bus-bar shall be insulated with colour code sleeves/ tapes and to be connected withAluminium lugs, including two coats of synthetic enameled paint on the surface externally & internally over a coat of red oxide primer paint incl necessary PCC (1:3:6 ) typeC2 in foundation all as directed ,comprisioning of the following:-.(Panel-2)Incoming:-(a)MCCB 4 pole, 160 Amps, 415 Volts25 KA - 01 No(b) Digital type Ampere meter 0-200 Amps with Cts & selecter switch - 01 Set(c) Digital type Volt meter 0-500 Volts with PTs & selecter switch - 01 Set (d) LED Indicating lamps for main supply indicating R, Y, B - 01 Set(Set of 3)(e) Aluminium Bas Bar rating 250 Amps - 01 Set(Set of 04) 22 Serial Item No. 21 (Contd....)Outgoing:-(a) MCCB 100 Amps, 415 Volts 4 pole, 16 KA - 01 No (For Phase-II). (b) MCCB 40 Amps, 415 Volts 4 pole, 16 KA - 03 Nos (c) MCCB 32 Amps, 415 Volts 4 pole, 16 KA - 01 No (For Sec Light).(c) Digital timer panel with contactor and wiring complete - 01 No . 23 Supply & fixstreet light bracket made out of 40 mm diaGI pipe, medium grade, 1.5 Mtr long, bent to shape as required, weld with 25/20 mm dia6 longGI pipefor fixing of light fitting including provision of suitable MS clamps (made out of 50x6mm flat iron) , nuts , bolts and washers tofixed with pole and luminary properly etc complete allas specified and directed . 24 Supply and fix PVC insulated and FR PVC sheathed, Copper conductor,(flexible) industrial cable, 1100 Volts, three core multistanded 2.5 Sqmm cross sectional area, connected from junction box to street light fitting etc complete allas specified and directed . 25 S&F weather proof juction box made of thermoplastic polycarbonate with gasket, comply with IP- 66, dust and jet water proof of size 205X255X112mm, suitable size for cable size upto 16 to 50 sqmm alongwith cable inter for terminal and three phase with neutral Aluminium busbar including controlled with MCB 6 Amp Ccurve complete with necessary item including a pairs of MS flat iron clamp of size 40x 5mm with 10mm nuts bolts of suitable length with washer , including 2 coats synthetic enamel aluminium paint ( first grade ) over a coat or red oxide primer suitable to fix in steet tubular pole/ PCC pole complete allas specified and directed . 26 M&L for boring of holes under road, pavement, hard standing mannually or by trenchless technology using ultra sounding technique and necessary machine or mannuallyetc as per site requirment including provision of 150mm dia HDPE Pipe etc complete allas specified and directed . 27 AIR CONDITIONERSupply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA etc complete allas specified and directed . 28 Supply and fix 20A MCB Protected Power Plug socket Unit complete allas specified and directed . 29 ARBORICULTURESupply and plantation of Dup grass including preparation of ground to required depth and fillingof sweet earth, cow dung and watering etc complete all as spefified and directed by Engr-in-Charge. 30 Supply and plantation of palm tree (height of tree not less than 45cm above ground level) incl preparation of ground to reqd depth and filling of sweet earth, cow dung and watering etc complete all as specified and directed by Engr-in-Charge. 31 Supply and plantation of hedges including preparation of ground to required depth and filling of sweet earth, cow dung and watering etc complete all as specified and directed by Engr-in-Charge. 32 Supply, laying, connecting and testing 20mm bore, galvanized mild steel tubing medium grade with and including all fittings, laid in trenches complete all as specified and directed by Engr-in-Charge. 33 S&F 20mm sprinkler with all accessories and fixed to 20mm bore GI pipe complete all as directed by Engr-in-Charge.(Note : GI pipe will be measured and paid separately in above Sl itemNo. 32)Note for Sl item No. 29 to 31 :- The above rates shall include the cost of maintenance schedule regular watering / Manure, weed outs other growths etc for a period of 01 Year after completion of work all as directed and specified.