| 1 | Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. |
| 2 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 3 | Of area 3 sq. metres and below |
| 4 | DismantlingW.C.Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge. |
| 5 | Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer- in-Charge.(a) Internal Work- Exposed on wall |
| 6 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 7 | For thickness of tiles 10 mm to 25 mm |
| 8 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws cmplete: |
| 9 | Ridges plain (500 - 600mm) |
| 10 | Steel work in built up tubular (round, square or rectangular hollow tubesetc.)trussesetc.,includingcutting,hoisting,fixingin position and applying a priming coat of approved steel primer, including welding andbolted withspecial shaped washers etc. complete. |
| 11 | Electric resistance or induction butt welded tubes |
| 12 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 13 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 14 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 15 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 16 | Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both verticalssides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long,including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer\"s specification and direction of engineer-in-charge. |
| 17 | Providing and fixing 37 mm thick factory made PVC Door shutter, styles and rails made of PVC hollow extruded printed and laminated section having overall dimension 115 mm x 37 mm with wall thickness 2 mm (± 0.2 mm) with inbuilt beading on one side, the styles and rails mitred cut and joint at corners by inserting 2 nos PVC profile reinforcement of size 75 mm x 200 mm long with cross section size of 28 mm x 30 mm having wall thickness 2 mm (± 0.2 mm). Styles, rails and reinforcements to be fusion welded together. Only hinge side vertical style to be reinforced with PVC profile reinforcement in full length. Printed and laminated PVC lock rail of size 110 mm x 37 mm having wall thickness 2 mm (± 0.2 mm) to be welded horizontally with the vertical styles after inserting PVC profile reinforcement as in styles and rails, providing with PVC snap fit beading, panels of 100 x 20 mm printed & laminated and inserting 2 nos 6 mm dia bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturer\"s specification and direction of engineer-in-charge. |
| 18 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 19 | Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) |
| 20 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 21 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 22 | Two coats |
| 23 | Finishing walls with Acrylic Smooth exterior paint of required shade . |
| 24 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 25 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 26 | Two or more coats on new work |
| 27 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications preparation of surface, etc. complete. |
| 28 | On Steel work |
| 29 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 30 | One or more coats on old work |
| 31 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 32 | Providing and fixing panelling or paneling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows ( area of opening for panel inserts excluding portion inside grooves or rebated to be measured). Panelling for panelled and glazed shutters 25mm to 40mm thick: Pre-laminated with decorative lamination on both side exterior Grade - I MDF Board 12 mm thick confirming to IS:14587 |
| 33 | Providing and fixing white vitreous china pedestal type water closet(European type) with seat and lid, 10 litre low level white vitreouschina flushing cistern & C.P. flush bend with fittings & C.I. brackets,40 mm flush bend, overflow arrangement with specials of standardmake and mosquito proof coupling of approved municipal designcomplete, including painting of fittings and brackets, cutting andmaking good the walls and floors wherever required : |
| 34 | W.C. pan with ISI marked white solid plastic seat and lid |
| 35 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brasspillar taps, 32 mm C.P. brass waste of standard pattern, includingpainting of fittings and brackets, cutting and making good the walls wherever require: |
| 36 | White Vitreous China Wash basin size 550x400 mmwith a pair of 15 mm C.P. brass pillar taps |
| 37 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings withonestep CPVCsolvent cementandthe cost of cutting chasesandmaking good thesame including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
| 38 | 20 mm nominal dia Pipes |
| 39 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work |
| 40 | 40 mm nominal dia Pipes |
| 41 | Providing and fixing CPVC Union in CPVC Pipe including cutting and joining the pipe etc, complete(New Work) |
| 42 | 20 mm nominal bore |
| 43 | 40 mm nominal bore |
| 44 | Providing and fixing brass bib cock of approved quality : |
| 45 | 20 mm nominal bore |
| 46 | Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete. (copper oxidized as per IS: 1378) |
| 47 | 300 mm weighing not less than 330 grams |
| 48 | Providing and fixing bright finished brass handles with screws etc. complete: |
| 49 | 125 mm |
| 50 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 51 | Twin rubber stopper |
| 52 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 53 | 300x16 mm |
| 54 | 250x16 mm |
| 55 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 56 | 250x10 mm |
| 57 | 150x10 mm |
| 58 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 59 | 125 mm |
| 60 | 100 mm |
| 61 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 62 | Glazed Vitrified tiles Matt/Antiskid finish of size -Size of Tile 600 x 600 mm |
| 63 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding pointing the joints with white cement and matching pigments etc., complete. |
| 64 | Providing and laying rectified anti skid floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours white, Ivory, Grey, Fume Red Brown, laid on 20mm thick cement mortor1:4(1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 65 | Size of tile 300x300 mm |
| 66 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 67 | Flexible pipe - 40 mm dia |
| 68 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 69 | 150 mm diameter |
| 70 | Providing and fixing plain multipurpose cement board(Hight pressure steamcured)withsuitablescrewsforcementparticleboardin ceiling etc. complete (frame work to be paid seperatately). |
| 71 | 6 mm thick Cement fiber board, Type-B, Category-III as per IS: 14862:2000 |
| 72 | Providing and fixing 600x450 mm beveled edge mirror of superiorglass (of approved quality) complete with 6 mm thick hard boardground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 73 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 74 | With cement mortar 1:4 (1 cement : 4 fine sand) |
| 75 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 76 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
| 77 | Providing and fixing in position eaves or facia board with 19mm marine (WPC) 30cm wide including fixing with nuts and bolts etc. complete. |
| 78 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 79 | Group-B |
| 80 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 81 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required |
| 82 | a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 83 | b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 84 | c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 85 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 86 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 87 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 88 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required |
| 89 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.. |
| 90 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required |
| 91 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required |
| 92 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 93 | a) Upto 450 mm sweep |
| 94 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng andfixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 Amodular switch, connections etc. as required. (For light plugs tobe used in non residential buildings). |
| 95 | Supplying and fixing of PVC Button / angle holder including connection etc. as required |
| 96 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 97 | a) 8 way , Double door |
| 98 | b) 12 way , Double door |
| 99 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 100 | a) Single Pole |
| 101 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 102 | a) 40 Amps |
| 103 | b) 63 Amps |
| 104 | Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required |
| 105 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required |
| 106 | Supplying installation, testing and commissioning of ASHLOK make SEE brand safe earthing electro type-19, 50mm dia length 2 mtrs and inner space to be filled with crystaline conductive mixture including filling up with elelctrodite (Back fill compound ) as reqd for safe earth electrode and providing masonary enclusure with cover plate having locling arrangement etc as reqd. |
| 107 | Supply of LED Bulb of 9 Watts B22 (Similar to Everday B22 Cool day light)or its equivalent to ISI specification make Panasonic, Havells, Bajaj, Crompton . |
| 108 | Supplying of integrated LED 10 W Bulk head luminaire, (similar to Murphy 10W wall Lamp LED Oval Shape IP54 Water proof cool white or equvilantmake Havells, Halonix, Bajaj etc. |
| 109 | Supplying ofDecorative ultra slim square profile LED 20 W 4 ft lighting fixture (similar to Philip 20 W LED Batten/Tubelight ultra compact 4ft) or its equivalent make Wipro, Crompton, Havells, Bajaj etc. |
| 110 | Supplying ofEnergy Saving 5 star rating, ISI, BLDC A.C. Ceiling fan 1200 mm sweep, with all accessories . (Similar to Polycab Eteri BLDC AC Ceiling Fan 1200 mm sweep ) or its equivalent make Havells, Crompton, Orient, Bajaj, V-Guard etc. |
| 111 | Supply of Metallic exhaust fan of size 230 mm (similar to Havells Make Model Ventil Air DSP) or its equivalent make Anchor, V-Guard, Bajaj, Orient etc. |
| 112 | Supplying and fixing of instant type water heater Geyser, instant water heater of 3Ltrs capacity , 6.5 bar Pressure, 240 V with05 year warranty (similar to Orient Electric Aura 3 ltrs)or its equivalent make Havells, Crompton, V-guard, Bajaj, Anchor etc. |