| 1 | Earthwork Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out theexcavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level In all types soils/ saturated soil such as moorum, sand, sandy silt,clay, black cotton soil, kankar, etc.Depth upto 1.5 m |
| 2 | PCC Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinthlevel1:5:10 (1 cement : 5 fine/ coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 3 | Shuttering Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting,propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete |
| 4 | Plinth Beam Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 5 | Tie Beam Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 6 | Roof Beam Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 7 | Roof Suspended floors, roofs, landings, balconies and access platform. |
| 8 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level : 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size)Footing |
| 9 | Brick work with FPS bricks of class designation 75 in superstructureabove plinth level upto two stories in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 10 | Brick work Half brick masonry with FPS bricks of class designation 75 insuperstructure above plinth level upto two stories.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 11 | Flooring Kota Stone Stone work ( machine cut edges) for wall lining upto 10 m height etc.(Veneer work) backing filled with a grout of 12mm thick cement mortar 1:3 (1 Cement : 3 coarse sand) and jointed with Cement mortar 1:2 (1 cement : 2 stone dust) including rubbing and polishingcomplete. (To be secured to the backing by means of cramps which shall be paid for separately) Kota stone slabs exposed face dressed and rubbed25 mm thick. |
| 12 | Steel Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars. |
| 13 | Cement plastering including T&P, scaffolding, material and completelabour, including cost of water, curing, racking of joints etc. with 12 mm cement plaster of mix :1:4 (1 cement : 4 fine/ coarse sand) |
| 14 | Providing and fixing factory made ISI marked steel glazed doors,windows and ventilators side /top /centre hung with beading and allmembers such as F7D, F4B, K11 B and K12 B etc. complete ofstandard rolled steel sections, joints mitred and flash butt weldedand sash bars tenoned and rivetted with 15x3mm lugs, 10cm long,embedded in cement concrete blocks 15x10x10cm of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominalsize) or with wooden plugs and screws or rawl plugs and screws orwith fixing clips or with bolts and nuts as required, includingproviding and fixing of hinges, pivots, float glass panes with glazingclips and special metal sash putty of approved make and a primingcoat of approved steel primer excluding the cost of metal beading and other fittings except necessary hinges or pivots complete as perapproved design. |
| 15 | Providing and fixing 1st quality standard white, grey, ivory, fume redbrown, light green, light blue and other light shades glazed tilesconfirming to IS : 13753 & IS :15622 of size 200mm x 300mm inwalls, floors, steps, pillars etc. laid on a bed of neat cement slurryfinished with flush pointing in the white cement mixed with pigmentto match the shade of the tile complete (excluding the cost ofcement plaster on walls and pillar). |
| 16 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) : Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 17 | Providing and fixing 12mm thick Pre-laminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on bothsides |
| 18 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in positionand applying a priming coat of approved steel primer all complete: |
| 19 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges andscrews and applying a priming coat of approved steel primer. |
| 20 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge (Cost of aluminium snap beading shall be paid in basic item) :With float glass panes of 5.50 mm thickness |
| 21 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 22 | Distempering with dry distemper of approved brand andmanufacture (two or more coats) and of required shade on new work, over and including priming coat of whiting to give an even shade |
| 23 | SANITARY WORK Providing and fixing Polyethelene-Aluminium-Polyethelene (PE-ALPE)Composite Pressure Pipes conforming to IS - 15450 U.V. stabilised with carbon black having thermal stability for hot & cold water supply, capable to with stand temperature up to 80 C includingall special fittings of composite material (engineering plastic blend and brass inserts wherever required ) e.g. elbows ,tees ,reducers,couplers & connectors etc. with clamps at 1.00 metre spacing. this includes testing of joints complete as per direction of the Engineer incharge. Internal work - Exposed on wall1216 (16 mm OD) pipe |
| 24 | SANITARY WORK Providing and fixing Polyethelene-Aluminium-Polyethelene (PE-ALPE)Composite Pressure Pipes conforming to IS - 15450 U.V. stabilised with carbon black having thermal stability for hot & cold water supply, capable to with stand temperature up to 80 C includingall special fittings of composite material (engineering plastic blend and brass inserts wherever required ) e.g. elbows ,tees ,reducers,couplers & connectors etc. with clamps at 1.00 metre spacing. this includes testing of joints complete as per direction of the Engineer incharge. Internal work - Exposed on wall2025 (25 mm OD) pipe |
| 25 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 26 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P.brass pillar taps,32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and making goodthe walls wherever require White Vitreous China Surgeon type wash basin of size 660x460 mmwith a pair of 15 mm C.P. brass pillar taps with elbow operatedlevers. |
| 27 | Providing and placing on terrace (at all floor levels) polyethylenewater storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outletand overflow pipes but without fittings and the base support for tank |
| 28 | Providing and fixing PTMT Ball cock of approved quality, colour andmake complete with Epoxy coated aluminium rod with L.P./ H.P.H.D.plastic ball. 25 mm nominal bore, 152mm long. Weighing not less than 440 gms. |
| 29 | Providing and fixing white vitreous china pedestal type water closet(European type) with seat and lid, 10 litre low level white vitreouschina flushing cistern & C.P. flush bend with fittings & C.I. brackets,40mm flush bend, overflow arrangement with specials of standardmake and mosquito proof coupling of approved municipal designcomplete including painting of fittings and brackets, cutting andmaking good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. |
| 30 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore |
| 31 | Constructing masonry Chamber 60x45x50 cm, inside with 75 classdesignation brick work in cement mortar 1:4 (1 cement : 4 coarse )sand) for water meter complete with C.I. double flap surface box400x200x200 mm (inside) with locking arrangement and RCC topslab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessaryexcavationfoundation concrete 1:5:10 ( 1 cement : 5 fine sand :10 graded stone aggregate 40 mmnominal size) and inside plastering with cement mortar 1:3 (1cement : 3 coarse sand) 12 mm thick finished with a floating coat ofneat cement complete as per standard design |
| 32 | Providing and fixing stone slab table rubbed, edges rounded andpolished of size 75x50 cm deep and 1.8 cm thick fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 6 mm nominal size) as per direction of Engineer-incharge and finished smooth. |
| 33 | Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures completeincluding cutting and making good the walls and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440mmwith integral type foot rests. |
| 34 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively |
| 35 | Providing and fixing mirror of superior glass (of approved quality)and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357mm |
| 36 | P.T.M.T. Soap Dish/ Holder 138*102*75 mm |
| 37 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore |
| 38 | Providing and fixing rigid PVC pipe fittings of approved quality / make including jointing the pipe with solvent cement rubber ring and lubricant coupler 110 mm dia |
| 39 | reducer 110*75mm |
| 40 | plain tee |
| 41 | Bend 45* |
| 42 | Pipe clip |
| 43 | vent cowel |
| 44 | Wiring of light point/ fan point/ exhaust fan point/ call bell point asper PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper n conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kVgrade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III )vergin material PVC conduit & it\"s all accessories( J.B. , Bends etc.), round tiles,18 SWG Hot Dipped Galvanized Modular Box with earthterminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / lamp Holder/ 3 pin connector , screws etc, makingconnections,all as per pre approved by Engineer in charge, testingetc. complete as required. For specification of copper Conductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 . For additional technical parametersof products/ work , refer Annexure \"A\" attached with this BSRShort point (up to 3 mtr.) |
| 45 | Medium point (up to 6 mtr.) |
| 46 | Long point (up to 10 mtr..) |
| 47 | Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) vergin material PVCconduit & it\"s all accessories( J.B. , Bends etc.) , round tiles,18 SWGG.I. box with earth terminal of required size, 6 A switch, 3/5 pin 6 Asocket, 3.0 mm thick ISI marked phenolic laminated sheet (IS : 2036- 1995), Al. alloy/ cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07. For additional technical parameters of products/ work , refer Annexure \"Aattached with this BSR on board |
| 48 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit as per PWD specification for electrical Works along with its accessories (IS: 3419 ) as required in recess including cutting the wall, covering conduit and making good the same as required. All relative and latest acceptance tests reports by any NABL accredited lab for the conduit shall be submitted before execution & All as per pre approved by Engineer in charge. Foradditional technical parameters of products/ work , refer Annexure attached BSR25mm |
| 49 | Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC, minimum phase termination capacity of35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections,testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as perpre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \"A\" attached with BSR Single pole MCBSingle pole MCB 6 A to 32 A rating |
| 50 | Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC, minimum phase termination capacity of35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections,testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as perpre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \"A\" attached with BSR Single pole MCBDouble pole MCB 6 A to 32 A rating |
| 51 | Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pinceiling roses as per PWD specification for electrical Works, madeout from industrial grade Polycarbonate or fire resistant ABSmaterial, brass terminal & captive screws including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 52 | Plate Earthing as per PWD specification for electrical Works as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with BSR |
| 53 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR8 SWG copper Wire |
| 54 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR25mm*3mm copper strip |