| 1 | Wiring for light point/ fan point/exhaust fan point /call bell point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate , suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 Pin 5/6A modular socket outlet and 5/6 A modular switch connections etc. as required. |
| 3 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 Pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch connections etc. as required. |
| 4 | S/F of 20A 240V SPN industrial type socket outlet with 2 pole and earth metal enclosed plug top alongwith 20A C curve SP MCB in sheet steel enlosure on surface or recess with changed metal cover for the socket outlet and complete with connection testing and commissioning etc. as required. |
| 5 | S/F of12waydouble door single pole and neutral sheet steel MCB DB 240V on surface & recess complete with tinned copper busbar , neutral busbar , earth bar , din bar interconnections powder painted inclduding earthing etc. complete (But without MCB /RCCB / Isolator) |
| 6 | S & Fof 6 Amp to 32 Amp SP MCB |
| 7 | S&F of 63A double pole 240V RCCB complete with connection etc. |
| 8 | S&F of 40A double pole 240V RCCB complete with connection etc. |
| 9 | Supplying and fixing of 6 way (4+18 doble door) surface/ recess mounting, vertical type, 415 V,TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 10 | S&F of call bellbuzzer suitable for single phase, 230 V complete as required. |
| 11 | Wiring for circuit / submain wiring alongwith earth wire with the following size FRLS PVC insulated copper condutor single core cable in surface / recessed medium class PVC conduit required. |
| 12 | 2x2.5sq.mm +1.0x2.5sq.mm earth wire. |
| 13 | 2x4 sq.mm +1x4sq.mm earth wire. |
| 14 | 2x6 sq.mm +1x6sq.mm earth wire. |
| 15 | 2x10 sq.mm +1x6sq.mm earth wire. |
| 16 | 4x16 sq.mm +1x10sq.mm earth wire. |
| 17 | SITC of 1200mm Sweep BEE 5 star rated , Ceiling Fan, with brush. etc. complete as per rquired. |
| 18 | S/F of 1x22 W led tube light fitting complete in all respect. |
| 19 | S/F of modular computer Board complete with 1 N0. 20 Amp switch and socket and 3 N0. 10 Amp switch and socket madular type. |
| 20 | Dismantling charges of old wiring and old panel |
| 21 | Add: GST @18% |