Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 29-04-2025 | OTHER CORRIGENDUM3 | Other | 03-05-2025 |
| 2 | 28-04-2025 | OTHER CORRIGENDUM2 | Other | 03-05-2025 |
| 3 | 25-04-2025 | OTHER CORRIGENDUM | Other | 03-05-2025 |
| 4 | 24-04-2025 | BOQ CORRIGENDUM | BOQ | 03-05-2025 |
| 5 | 16-04-2025 | DATE CORRIGENDUM | Date | 03-05-2025 |
| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as specified and directed. |
| 2 | Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, (Below or above ground level) complete all as specified. |
| 3 | M&L for Coloured Glazed ceramic tiles in vertical surface450 x 300 x 7 mmthick (Concept pattern Tiles) set and jointed in neat cement slurry and pointed in white or Coloured cement to match including 10mm thick backing coat in CM 1:4 complete all as specified and directed. |
| 4 | M&L for Non-Skid Ceramic coloured tiles 7 to 8 mm thick (Square/ Rectangular) polished, light shade, area of each tile exc 0.18 Sqm butnot exceeding 0.38 sqm, in floors by providing 3mm spacers and filling with epoxy grout matching color with tiles by applying masking tape etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 5 | M&L for Non-Skid Ceramic coloured tiles 7 to 8 mm thick (Square/ Rectangular) polished, light shade, area of each tile exc 0.18 Sqm butnot exceeding 0.38 Sqm, in Skirting/Dado etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match. over and including 10mm thick backing coat in CM 1:4 complete all as specified and directed. |
| 6 | M&L for Vitrified ceramic coloured tiles 10 mm thick (Square/ Rectangular) polished, light shade, area of each tile exc 0.18 sqm butnot exceeding 0.36 sqm, in floors by providing 3mm spacers and filling with epoxy grout matching color with tiles by applying masking tape etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 7 | M&L for Vitrified ceramiccoloured tiles 10 mm thick (Square/ Rectangular) polished, light shade, area of each tile exc 0.18 sqm butnot exceeding 0.38 sqm, in Skirting/Dado set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 10mm thick plaster in CM 1:4 complete all as specified and directed. |
| 8 | M&L for 25 mm thick PCC 1:2:4 type B0 (Using 12.5mm graded stone aggregate) in sub base of floorings finishing the cement concrete surfaces even and fair complete all as specified and directed. |
| 9 | M&L for 75 mm thick Cement concrete 1:3:6 type C1(using 20 mm graded stone aggregate) in plinth protection, and finishing the concrete surface even and smooth without using extra cement including making joints filled with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed. |
| 10 | M&L for 100 mm thick cement concrete 1:2:4 type B- 1 (20 mm grade aggregate) as in base of flooring/hard standing, etc, and finishing the cement concrete surfaces even and smooth without using extra cement complete all as specified and directed. |
| 11 | M&L for forming 12mm thick,100 mm deep expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A complete all as specified and directed. |
| 12 | M&L for 75 mm thick cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as in sub base floors, and finishing the concrete surface even and fair complete all as specified and directed. |
| 13 | M&L for preparation of old decorated surface by complete removal of existing treatment on wall, washing, rubbing, stopping etc and applyingtwo coats of oil bound washable distemper over a coat ofprimer including applying 3 mm thick wall care putty to a smooth surface including making good any undulations on the surfacescomplete all as specified and as directed.Note :- (i) Painting work shall be carried out acoording to Smart Painting procedure mentioned in PS(ii) Sanding of surfaces shall be done by mechanical sander with 1500-2700 rpm with internal dust extraction system for clean environment certified by the Paint manufacturer) |
| 14 | M&L for preparation of old decorated surface by complete removal of existing treatment from ceiling, washing, rubbing, stopping etc and applyingtwo coats of oil bound washable distemper over a coat ofprimer including applying 3 mm thick wall care putty to a smooth surface including making good any undulations on the surfacescomplete all as specified and as directed.Note :- (i) Painting work shall be carried out acoording to Smart Painting procedure mentioned in PS(ii) Sanding of surfaces shall be done by mechanical sander with 1500-2700 rpm with internal dust extraction system for clean environment certified by the Paint manufacturer) |
| 15 | M&L for preparation of old decorated surface of external wall by complete removal of existing treatment, washing, rubbing, stopping etc and applyingtwo coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre having weather proof, dart pick up resistant,silicon enhanced,UV resistant and PU enhanced propertyover a coat of alkali resistant primer including applying one or more coat of wall care putty to a smooth surface including making good any undulations on the surfacesincluding all necessary scaffolding,complete all as specified and directed.Note :- Painting work shall be carried out acoording to Smart Painting procedure mentioned in PS (ii) Sanding of surfaces shall be done by mechanical sander with 1500-2700 rpm with internal dust extraction system for clean environment certified by the Paint manufacturer) |
| 16 | M & L for preparation of old ceiling surfaces and applying one coats of white wash complete all as specified and directed. |
| 17 | M&L for preparation old painted wooden surfaces and applying one coats of synthetic enamelpaint complete all as specified and directed. |
| 18 | M&L for preparation old painted steel surfaces and applying one coats of synthetic enamelpaint complete all as specified and directed. |
| 19 | Taking down chowkats or frames with shutters exceeding 1.5 Sqm each but n.exc 4 sqm each (Without taking off shutters from the frames) complete all as specified and directed. |
| 20 | Taking down chowkats or frames with shutters not exceeding 1.5 Sq. m each (Without taking off shutters from the frames) complete all as specified and directed. |
| 21 | Taking down shutters exc 1 sqm and n exc 2 sqm each complete all as specified and directed. |
| 22 | S&F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium frame for doors, windows, ventilators, etc., with one or more rebates including joining cleat for fixing etc., complete all as specified and directed. |
| 23 | S&F anodised aluminium with powder coating any colour (minimum thickness of powder coating 50microns) door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed |
| 24 | S&F Anodised aluminiumwith powder coating any colour (minimum thickness of powder coating 50microns) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle(1 no.) complete all as specified and directed |
| 25 | S & F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. |
| 26 | S & F Second class hard wood plain, solid, straight Chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 27 | M&L for preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described, and treated with tar or coal tar black paintcomplete all as specified and directed. |
| 28 | S & F Mild steel sections in supports for stiffening of fencing, wall ties, holdfasts, clamps, plain angle cleats for securing purlins and similar small articles confirming to Fe 290 Gde E-165 complete all as specified and directed. |
| 29 | M & L for plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) for embedding holdfast, bed block, cills, etcincluding necessary form work complete all as specified and directed. |
| 30 | S & F 35 mm thick, factory made Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 31 | M&L for 4mm thick Veneered decorative plywood, grade1 (with BWR resin) with decorative face veneers on both faces; fixed with screws to timber complete all as specified and directed. |
| 32 | S&F Wood Plastic Composite (WPC) factory made door frames of Cross section 125mmX65mm having doudle rebate design made out of singlepiece extruded WPC profile with homogenous fine celluar structure made with virgin PVC polymer,calcium carbonate ,wood powder and non toxic additives having Solid Structure which is E-co friendly, high grade UV resistant and with heat, fire retardent will be miterd & jointed with 120mm x 8mm in the corner of frames after applying PVC solvent cement and fixing of frame with self driven screws of size 100mm x8mmwith wooden plug complete all as specified and directed.Note :-Tolerance limit in Size shall be (+/-2MM) in all dimensions. |
| 33 | S&F 35 mm thick factory made wooden Flush Doors conforming toIS-2202 made from imported Pine/Southern Yellow Pine filler and 2.5 mm thick core Veneer on both side and 0.4mm thick Face veneer on both side with lock rails in the centre peripherals ,pasted with approved laminate on both side. Outer peripherals of the flush doors lipped with Teak wood beeding patti of 35mmx12mm complete all as specified and directed. Note :- (i) Flush Doors having warranty against borer, decay,cracks,bending and twisting. (ii) Lamination on both side shall be pressed by cold press process (iii)The flush doors shall be delivered packed in PVC bags or stretch wrapped. |
| 34 | S & F 35 mm thick, factory made, glazed/skeleton shutters with 1st class hard wood,open rebated and prepared to receive glass, gauze, etc (without sash bars)edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass, etc complete as specified and directed . Sizes of members of shutters as specified in SSR Part I, clause 8.24 (a) complete all as specified and directed |
| 35 | S & F 35 mm thick, 2nd class hardwood, factory made, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 36 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full Body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm 2 , modules of elasticity 900 N/mm 2 and resistance to spread of flame of Class A category with water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 37 | S&F 30mm thick Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive trength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body hreaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges with S S screws shall be paid separately) complete all as specified and directed. |
| 38 | M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed. |
| 39 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples. |
| 40 | S& F in repairs stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples. |
| 41 | S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, taple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete as specified and directed |
| 42 | S&F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section Complete all as specified and directed |
| 43 | S&F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 44 | S&F 125mm Butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 45 | S&F Floor door stopper aluminium alloy body including rubber tip , nickle plated to give a stainless steel finish , fixed with door to do up and down actionto giving the rubber tip a good grip on the floor complete all as specified and directed. |
| 46 | S&F Door closer aluminum die cast body hydraullically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed completeall as specified and directed. |
| 47 | S&F in repairs 300mm, ordinary rat tail rod pattern springs including roller and roller plate completeall as specified and directed. |
| 48 | S & F 4.0 mm thick sheet glass, ordinary quality and glazing with oil putty/ aluminium/ wooden beading in square exc 0.5 sq. m in each pane completeall as specified and directed. |
| 49 | S & F in repairs 4.0 mm sheet Glasspin head type and glazing with oil putty in squares exc 0.5 sq. m in each pane incl hacking out old glass from metal frame complete all as specified and directed. |
| 50 | S&F 5.5 mm thicksheet glass,glazing with oil putty and glazing clips in metal/ wooden frame with second class hard wood beading/ aluminum beading in frames in squaresexceeding 0.5 Sqm in each pane complete all as specified and directed |
| 51 | S&F 12 mm thick, Prelaminated particle board, exterior grade, prelaminated both side with decorative choice laminationfixed with screws to timber/metal frame work complete all as specified and directed. |
| 52 | S&F in repair2 mm thick, Prelaminated particle board, exterior grade, prelaminated both side with decorative choice laminationfixed with screws to timber/metal frame work complete all as specified and directed. |
| 53 | S&F 125 mm long extruded Aluminium alloy anodised Butt hinges with galvanized mild steel hinge pin type B 22 complete all as specified and directed by Engr-in-Charge. |
| 54 | S&F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed |
| 55 | S&F 150 mm long extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 56 | S&F in repair 18mm Plywood, grade BWP, type BB fixed with screws to timber frame work complete all as specified and as directed . |
| 57 | S & F 75 mm long medium weight, stainless steel Butt hinges auto cabinet self closing type complete all as specified and as directed |
| 58 | S&F magnetic catches of superior quality, plastic body and striking plate for cupboard shutters complete all as specified and as directed. |
| 59 | S&F 150mm Long extruded brass handles fabricated type polished complete all as specified and directed |
| 60 | S&F 0.90 mm thick decorative lamination type - I as per approved colour and pattern shall be fixed with adhesive as per manufacturer\"s instruction complete all as specified and directed. |
| 61 | M&L for followings :-(i) Removing plaster & finishes all around the coloumns, slabs & beams (on all four sidescription of column to full height , three sidescription of beam to entire span & bottom of slab to area as directed)(ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible)(iii) Removal of cover concrete with under cutting of up to a depth of 20mm beyond reinforcement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed)(iv) Cleaning exposed concrete substrate by using water jet.(v) Removing visible rust along the length of reinforcement using hand tools as approved.(The Engr-in-charge may order sand blasting if rust is approved)(vi) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed. |
| 62 | M&L for providing rust proof /anti corrosive treatment to bars :-(i) cleaning of all exposed bars (new & old) alround(ii) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufactuer(iii) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars alround new & old as recommended by the manufactuer. Note : Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re bars (those towards the concrete substrate) should not be left without coating. |
| 63 | M&L for providing PMM (Polymer modified cementitious mortar) :-(i) Dry sub strate surface and free of debris & dust(ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes).(iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) of 25 mm thickness.Note :Application of PMM shall be preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use.(iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed. |
| 64 | M&L for Providing & Pouring Micro concreting M-40 grade :-(i) Dry concrete substrate surface and free of debris & dust(ii) Applying Epoxy bond coat on the sound concrete substrate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes).(iii) Immediately after application of epoxy bond coat as above pour Micro concreting M40 grade, Make : MasterEmaco S46T of BASF or equivalent FOSROC/SIKA using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc,. Adding of aggregates will be permitted only as per manufacturer’s recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labour charges for mixing, pouring concrete, cost of tools, lead & lift of materials, transportation etc (iv) use & waste of form work using steel sheets , steel bracing, propping etc around structural members where micro concreting to be done and keeping form work in position till required specified period to carry out the complete work complete all as specified and directed.Note : (a)The cost of micro concrete M-40 grade & Epoxy bond coat is inclueded in this item. (b) Form work shall be 100% leak proof. |
| 65 | M&Lfor introducing new reinforcement bars upto 10 mm dia cut to length, bent to shape required, includingcranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipsfor structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced cement concrete to a minimum depth of 150 mm and upto 200 mm including power drilling,fixing the reinforcement in position using epoxy resin anchoring mortar, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc all as specified and directed.Make :- Hilti HY 150/ Fosroc Lockfix E 75 /Master flow 935 of BASF chemical or quivalents solutions SIKA /STP/ HINDCONas approved by GE. |
| 66 | M&Lfor introducing new reinforcement bars over 10 mm dia cut to length, bent to shape required, includingcranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipsfor structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced cement concrete to a minimum depth of 150 mm and upto 200mm including power drilling,fixing the reinforcement in position using epoxy resin anchoring mortar, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc all as specified and directed.Make :- Hilti HY 150/ Fosroc Lockfix E 75/ Master flow 935 of BASF chemical or quivalents solutions SIKA /STP/ HINDCONas approved by GE. |
| 67 | M&L for chipping of spalled and loose concrete and cleaning rust from re-inforcement by sand brushing scrubing down concrete surfaces with wire brushes cleaning with water allowed to dry applying a layer of two component epoxy zinc rich primer as antirust on all exposed reinforcement followed by a layer of bonding coat of applying two component epoxy bonding agenton complete exposed surfaces of concrete and provide guniting in two layers over steel welded mesh 2 mm dia of wire and total aperture 75 mm, thickness of gunite n.exc 25 mm thick (average thickness) using cement mortar 1 :3 with OPC 43 grade cement mixed with polycrete admixture @ 2 % by wight of cement or as per manufactures instructions and finally applying cement plaster over gunite surfaces ofrequired thickness to give an even uniform and smooth finish conforming to proper Geometrics to match with the existing surface as in side and soffits of slabs,chajjas,fins,facias ,parapets ,columns and beams etc complete including necessary scaffolding ,shuttering necessarychased to brick work or RCC members at any height upto four storey buildings incl removing of small trees shrubs etc all as specified(Note: steel welded mesh to be welded with the existing reinforcement.The cost of welded meshis to be welded with the existing re-inforcement is deemed to be included in the quoted rate complete all as specified and directed.Make- (a)Two component epoxy zinc rich primer :- Nitozinc primer of FOSROC or equivalents chemical of SIKA/ STP/ HINDCON as approved by GE.(b) Two component epoxy bonding agent :- Nitobond EP (Std) of FOSROC or equivalents chemical of SIKA / STP / HINDCONas approved by GE. |
| 68 | Demolition of reinforced Cement Concrete of any description and in floor and roofs (other than ground floor), and disposal of unserviceablematerials, debris and rubbish to a distance not exceeding 100 Mcomplete all as specified and directed. |
| 69 | M & L for cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specified and as directed. |
| 70 | S&F Mild steel TMT bars 6 mm to 8 mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed. |
| 71 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises, where directed and leaving the work clear complete all as specified and directed. |
| 72 | M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4,mixed with integral water proofing compoundwith weight of cement in top layer as per manufacturer\"s instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item). |
| 73 | Supply only integral water proofing compound [ISI marked] of approved make. |
| 74 | M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and fair without using extra cement complete all as specified and directed. |
| 75 | M&L for rendering 5mm thick in CM 1:3 on any faces of concrete surfaces finished fair and even without using extra cement in ceiling/ chajja completeall as specified and as directed. |
| 76 | M&L for preparation of new platered surface of wall and applyingtwo coats of weather proof 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre, dart pick up resistant,silicon enhanced,UV resistant and PU enhanced propertyover a coat of alkali resistant primer including applying one or more coat of wall care putty to a smooth surface including making good any undulations on the surfacesincluding all necessary scaffolding,complete all as specified and directed.Note :-Painting work shall be carried out acoording to Smart Painting procedure mentioned in PS |
| 77 | M&L for preparation of new platered surface of wall and applying two coats of oil bound distemperover a coat ofprimer including applying one or more coat of wall care putty to a smooth surface including making good any undulations on the surfacescomplete all as specified and as directed.Note :- Painting work shall be carried out acoording to Smart Painting procedure mentioned in PS |
| 78 | M & L for preparation of new ceiling surfaces and applying three coats of white wash complete all as specified and directed. |
| 79 | S & F in repair 0.71mm thick Plain Aluminium sheeting Alloy 31000 H4 in stepped flashing (measured as the minimum rectangle from which the pieces can be cut), ridges, Hips, Valley Gutter, drip and straight flashing, Cover for Crumple Joint complete all as specified and as directed. |
| 80 | Demolition of un-reinforced Cement Concrete of any description and in floor and roofs (other than ground floor) and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 M complete all as specified and as directed. |
| 81 | M&L for preparation of horizontal or vertical surfaces for water proofing treatment on existing cleaned non accessible RCC roof with the following specification and manufacturings instruction complete all as specified and as directed:-(a) Preparing and cleaning of fully dry surfaces as per IS3067-1966(b) Applying bitumen primer(85/25 grade)conforming to IS:3384-1968 over the cleaned plaster surface @ 0.5 Ltr per sqm by the same membrane manufacturer of density at 25°C, 0.87 to 0.89 kg / Liter and viscosity 70-160 cps shall be applied on the prepared surface.(c) Applying a layer of APP based polymeric membrance 3.0mm thick (minimum) weight 3.6Kg per sqm (reinforced) with polyster Non woven fabric weighing not less than 160gms per sqm by torch application.The over laps shall be minimum 100mm on the transverse direction and 75 mm on longitudinal direction. (d) Applying one coat of aluminium paint @0.10 ltr per sqm over APP based polymeric membrane. |
| 82 | M & L for Plain cement concrete 1:5:10, type E-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed. |
| 83 | M & L for preparation of the sunken floor surfaces by mechanical abrading to remove all loose mortar and laitance, oil, grease etc and washing with plenty of water, making the surfaces sound and free from cracks by cutting \"V\" grooves cut along the cracks and filling with single component polymer modified repair mortarand carrying initial pond test for 24 hours to identify any invisible cracks, injection grouting for cracks on negative side of the surface usingplasticized expanding grout admixture @ 250 gms/50 Kg bag of cement with neat cement slurry by drilling the hole of 12mm dia and fixing the nozzles using single component instant leak plugging compoundalong the construction joints, cracks etc at a distance of not more than 500mm angle fillet, providing a cement sand mortar based fillet of 50x50mm admixed with high performance acrylic emulsion based binder @ 0.25 Litre per 50 Kg of cement all around in the side at the floor and wall junction and curing by water as per standard practice, applying two component elestomeric acrylic polymer modified cementitous water proofing coating . The mixing ratio of the coating shall be 2 parts of powder and 1 part of liquid without any water addition in the mixing complete all as per the manufacturer\"s instruction at a consumption factor of 1.5Kg/Sqm in two coats complete all as specified and as directed. Make of chemical:-(a) Single component polymer modified repair mortar :- SMARTCARE ofAsian Paints or equivelant of STP/Fosroc(b) Plasticized expanding grout admixture :- SMARTCARE Injection Grout Additive for cementofAsian Paints or equivelant of STP/Fosroc(c) Single component instant leak plugging compound : - SMARTCARE Instant Leak StopofAsian Paints or equivelant of STP/Fosroc (d) High performance acrylic emulsion based binder : -SmartCare Multi-purpose Polymer ofAsian Paints or equivelant of STP/Fosroc(e) Elestomeric acrylic polymer modified cementitous water proofing coating :- Smart Care Damp Block 2K Suprema of Asian Paint or equivelant as approved |
| 84 | M & L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces mixed with an integral liquid waterproofing compound as admixture @ 100ml per bag of cement finished the surface rough complete all as specified and as directed. Make : SMARTCARE Vitalia of Asian Paint or equivalent product of Dr Fixit,Sika,Dulax |
| 85 | M & L for treatment around the pipes of any dia passing through walls (Core cut area) by wrapping around all the pipes with acrylic emulsion based binder and placed appropriately in the same positionandthe gaps between the pipe and the core cutting shall be grouted by using high strength, non- shrink cementitious grout complete all as per the manufacturer\"s instruction and as directed. Make of chemical: APL Smart care (Asian Paints) or equivelant of STP/Fosroc |
| 86 | S & F in repair Towel Ring CPfixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) as specified and as directed by Engr-in-charge. |
| 87 | S & F in repair CP Towel rack 600 mm long with lower hangerfixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) as specified and as directed by Engr-in-charge. |
| 88 | S&F in repair CP health faucet with 8mm Dia, 1.2 Meter Long Flexible Tube & Wall Hooks complete all as specified and directed. |
| 89 | S&F in repair 15 mm bore 2 in 1 bib cock, chromium plated with wall flangescomplete all as specified and directed. |
| 90 | S&F in repairs, Toilet paper holder with cover, brass, chromium plated fixed to wall with brass screw complete all as specified and directed |
| 91 | S&F in repairs 15 mm bore Fancy type pillar taps, long swan neck type with quarter turn, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed. |
| 92 | S&F in repair 15 mm bore, angular stop cock with wall flange, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 93 | S&F in repair Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 94 | S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 95 | S&F in repairs, 15mm bore, bib taps, fancy type cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 96 | S & F in repairs, vitreous China wash down water closet pan (pedestal pattern) of size350x480x395 mm white, including connection to outgoing drain andflushing pipe, anti syphonic pipe, P or S trap with PVC water closet seat cover, black or white or coloured ,closed pattern with flat bottom andmild steel chromium plated hinging device complete but excluding flushing cistern & flush pipe including making good damaged/disturbed surfaces complete all as specified and directed. |
| 97 | S & F in repairs, 10 litre capacity, PVC valve less syphonic action type, flushing cistern, low level, white,with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and directed. |
| 98 | S&F in repair vitreous China wash hand basin table top thin rim white coloured, rectangular shape, of size : 495x395x150 mm including cutting for and pinning in ends of brackets or making suitable size of hole for pillar tap in RCC slab and granite hole complete all as specified and directed |
| 99 | S & F in repairs Chromium plated shower rose 125 mm size with or without swivel joints fixing to steel pipe or union complete all as specified and directed. . |
| 100 | S&F in repair PVC waste pipe of bore 32 mm and 800mm longto WHB complete all as specified and directed. |
| 101 | S&F in repair PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed. |
| 102 | S&F in repair PVC (SWR) Floor trap of 75 mm dia., outlet with grating including jointing with solvent cement complete all as specified and directed. |
| 103 | S&F PVC (SWR) multi Floor trap of 75 mm dia.,outlet with gratingincluding jointing with solvent cement complete all as specified and directed. |
| 104 | S&F in repair 600 mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 105 | S&F in repairs CP wall Mixer 3-in-1 System complete with 115mm Long Bend Pipe, Connecting Legs & Wall Flange complete all as specified and directed. |
| 106 | S & F in repairs, acrylic PVC bathroom cabinet of size 622 x 422 mm with openable shutter fixed with looking mirror of selected quality and with suitable shelves in side the cabinet of superior quality complete all as specified and directed |
| 107 | S & F in repair Stainless steelbrackets suitable for 20mm dia curtain rod (minimum projection from wall 100 mm) fixed in wall including drilling, rawl plug, screws etc complete all as specified and directed |
| 108 | S&F in repair Stainless Steelcurtain rod 20mm dia as in doors and windows partitions of approved make etc complete all as specified and directed |
| 109 | Taking up or down 20mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. |
| 110 | Taking up or down 32 mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. |
| 111 | Taking up or down 50 mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. |
| 112 | S&F 20 mm outer dia ,CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all asspecified and directed. |
| 113 | S&F 32 mm outer dia ,CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all asspecified and directed. |
| 114 | S&F 50 mm outer dia ,CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all asspecified and directed. |
| 115 | S & F in repair20 mm bore, gun metal, globe or Gate valves with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed. |
| 116 | S & F in repair32 mm bore, gun metal, globe or Gate valves with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed. |
| 117 | S & F in repair50 mm bore, gun metal, globe or Gate valves with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed. |
| 118 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etccomplete all as directed. |
| 119 | S&F 110mm bore PVC (SWR) pipes single socketed Soil waste and vent pipes in any length with or without ears with rubber ring joints fixed to walls complete all as specified and directed. |
| 120 | S&F 110mm bore PVC (SWR) pipes single socketed Soil waste and vent pipes in any length with or without ears with rubber ring jointslaid in trenchs complete all as specified and directed. |
| 121 | S&F75mm bore PVC (SWR) pipes single socketed Soil waste and vent pipes in any length with or without ears with rubber ring jointslaid in trenchs complete all as specified and directed. |
| 122 | S&F 75 mm bore PVC (SWR) pipes single socketed Soil waste and vent pipes in any length with or without ears with rubber ring joints fixed to walls complete all as specified and directed. |
| 123 | S&F110mmbore PVC (SWR) bends any radius complete all as specified and directed. |
| 124 | S&F 110mmbore PVC (SWR) bends any radius with access doors complete all as specified and directed. |
| 125 | S&F 75mmbore PVC (SWR) bends any radius complete all as specified and directed. |
| 126 | S&F 75 mmbore PVC (SWR) bends any radius with access doorscomplete all as specified and directed. |
| 127 | S & F 75 mm bore PVC (SWR) junction single (Single `T\") equal or unequal complete all as specified and directed. |
| 128 | S & F 75 mm bore PVC (SWR)junction single (Single `T\") equal or unequal with access doors complete all as specified and directed. |
| 129 | S & F 110 mm bore PVC (SWR) junction single (Single `T\") equal or unequal with access doors complete all as specified and directed. |
| 130 | S&F 110mm bore PVC (SWR) vent cowl complete all as specified and directed. |
| 131 | S&FPVC (SWR) gullytrap of 125/110 mm dia., outlet with grating including jointing with solvent cement complete all as specified and directed. |
| 132 | M & L for Providing and injecting chemical emulsion for post construction Anti Termite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) at the rate of 0.50 litres per hole by drilling 6 mm dia., holes at a down ward angleof 45 degree at 150 mm centre to centre and sealing the same to match with the existing finish complete all as specified and directed. |
| 133 | M & L for Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed. |
| 134 | M&L for treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre includingdrilling and plugging holes etc. in apron complete all as specified and directed. |
| 135 | S&F 2000 litres capacityrotational moulded polyethylene water storage tanks, double layer construction, ISI marked (Cylindrical vertical with closed top), hoisted and fixed in positionas specified in SSR Part Iincluding disconnecting existing/old one complete all as specified and directed. |
| 136 | S&F in repairs 20 mm dia PTMT ball Valves, high pressure, with polythene float and fly nut complete, screwed for Iron pipe or brass ferrule complete all as specified and directed. |
| 137 | Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc and disposal ofdebris and rubbish to a distance n.exe 100 m as directed by the Engr-in-Charge. |
| 138 | M&L for Pre-cast cement concrete block masonry with solidblocks made out of PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) , exc. 10 cm in width and setting in cemet mortar 1:6 complete complete all as specified and directed. |
| 139 | M&L Brick work with fly ash bricks, bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed. |
| 140 | Dismantling wall & ceiling boards (fiber, pulp, insulation etc.) or insulation boards/ slabs/ blankets any thickness, including cover fillets / frame complete all as specified and directed. |
| 141 | S & F Gl frame work for seamless ceiling in two layers comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre tocentre complete all as specified and directed. |
| 142 | Providing and fixing Gypsum Board, 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and directed. |
| 143 | M & L for preparation of new ceiling surfaces and applying two coats of distemper oil emulsion over a coatalkali resistant primer over a coat of of wall care putty complete all as specified and directed. |
| 144 | S&F.designer cornices mouilding suitable for seamless ceiling board not less than 75mm wide or as per the manufacture\"s instructionscomplete all as specified and directed. |
| 145 | Dismantling of stone slabs & tiles of any description or thickness laid in CM and pointed in any mortar, in floors, aprons etc., complete all as specified and directed. |
| 146 | S&F 18 to 20mm thick Green Marble work (table rubbed and polished) in floors, steps, jambs, pillars, window-cills, cooking platforms and like bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match with marble shade incincluding 15 mm thick screed bed in cement mortar 1:6 & cutting, polishing complete all as specified and directed. |
| 147 | M & L for 18 to 20mm thick Granite (of any type) work (table rubbed and polished) in floors, steps, jambs, pillars, window-cills, cooking platforms and like bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 15 mm thick screed bed in cement mortar 1:6 & cutting, polishing complete all as specified and directed. |
| 148 | Dismantling timber scantlings 40 sq. cm and over in section, framed work in any position complete all as specified and directed |
| 149 | S&F stainless steel (Grade 316) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement including dismantling of old MS/Aluminum railing work/frame work complete all as specified and directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail